The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Size: px
Start display at page:

Download "The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:"

Transcription

1 Dream Kit

2 The NAMIC Dream Kit Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more than 40 years, NAMIC * Fluid Management products have been providing cardiologists, technicians and nurses with the Gold Standard in quality and reliability. As procedures, techniques and clinical requirements continue to evolve, AngioDynamics is committed to bringing you solutions to help meet your lab s changing needs. Introducing the NAMIC Dream Kit through our Fluid Management program, designed to: Help increase lab efficiencies Reduce number of hand tighten connection points Minimize contrast waste and maximize contrast budgets Dual back check valve eliminates the need to turn a stopcock when drawing contrast Compensator * Manifold Take pressure readings at any level 1 Integral transducer is 100% tested for accuracy Single operator set-up and re-zeroing Transducer closer to the pressure source How the Compensator Manifold Works: Compensator Port Unique Star Handle Design Large gripping surface Pressure Transducer OPEN POSITION CLOSED POSITION flexcil * Contrast Injection Line Allows for high pressure injections Provides flexibility Various lengths available to provide a single solution for both femoral and radial access 360 Star Handle Continuous Pressure Monitoring 2 Fewer manipulations 3

3 Squeeze * Contrast Controller Minimize contrast waste by utilizing larger bottles of contrast for multiple patients 4 Prevent cross contamination to the contrast source 4 Green Ball provides air embolization protection when fluids have depleted from the chamber Contrast Management Line available with and without chamber Dual Back Check Valve Decrease hand manipulations Allows for single-hand injection Designed to aspirate and inject contrast without manual manipulation of a stopcock handle 3 Acceler-8 * Syringe Slim barrel design designed to reduce the amount of force during injection and aspiration 5 Split collar retention designed to prevent plunger pull out Provides smoother aspiration and injection 5 1. Must have fluid filled pressure monitoring line attached to Compensator Port and after initial zero at heart level 2. Except during injections 3. Fewer manipulations than Standard Manifolds with non-360 handles. 4. Refer to contrast manufacturer s instructions for use 5. Data on file

4 Pre-bonded Manifold Assemblies Select a pre-bonded manifold assembly based on your labs needs. Type of Manifold Length Tubing Type Compensator Manifold Manifold Extension Line Manifold Syringe Extension Line Number of Ports Handle Style On/Off Contrast Port Saline Fluid Delivery Length Tubing Type 1 Off Dual Back Check Valve cm (6 ) Extension 2 Star Off Star Off Dual Back Check Valve Star Off Dual Back Check Valve Star Off Dual Back Check Valve w/ Vented Chambered Spike 76 cm (30 ) LPCIL cm (10 ) flexcil 3 Star Off 25 cm (10 ) LPCIL cm (10 ) flexcil 3 Star Off Dual Back Check Valve cm (10 ) flexcil 3 Star Off cm (10 ) flexcil 3 Star Off Dual Back Check Valve 76 cm (30 ) LPCIL cm (10 ) flexcil 3 Star Off 25 cm (10 ) flexcil cm (10 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL cm (20 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL cm (20 ) flexcil 3 Star Off 25 cm (10 ) flexcil cm (20 ) flexcil 3 Star Off Dual Back Check Valve 51 cm (20 ) LPCIL cm (20 ) flexcil 3 Star Off Dual Back Check Valve cm (30 ) flexcil 3 Star Off Dual Back Check Valve cm (30 ) flexcil 3 Star Off Dual Back Check Valve 25 cm (10 ) LPCIL Star Off Dual Back Check Valve 183 cm Vented Chamber (72 ) Star Off Dual Back Check Valve 76 cm (30 ) LPCIL Star Off Dual Back Check Valve w/ Chambered Spike Star Off Dual Back Check Valve 25 cm (10 ) LPCIL Star Off Dual Back Check Valve w/ Vented Chambered Spike 51 cm (20 ) LPCIL Star Off Dual Back Check Valve NAMIC Manifold 25 cm (10 ) flexcil 4 Star Off Dual Back Check Valve 76 cm (30 ) flexcil cm (10 ) HPCIL 3 Star Off Dual Back Check Valve cm (12 ) Extension 3 Off Dual Back Check Valve cm (18 ) Extension 3 Off Dual Back Check Valve cm (6 ) Extension 3 Off Dual Back Check Valve Perceptor Manifold 15 cm (6 ) Extension 3 Off Dual Back Check Valve Off Dual Back Check Valve Each pre-bonded kit is set up for right-handed configuration, with medium manifold pressure. Single sterile numbers and units are not available.

5 Components Adult Pressure Monitoring Lines Fittings Length Female Male 122 cm (48 ) H Box/25 Female Male 152 cm (60 ) H Box/25 Angiographic Control Syringes As shown: As shown: Barrel Size Plunger Style Barrel Style Fitting 0.5 ml Reservoir 7 ml Thumb Ring Finger Ring Fixed MLL Yes H Box/25 7 ml Thumb Ring Finger Ring Fixed MLL No H Box/25 7 ml Thumb Ring Finger Ring Rotating Adaptor Yes H Box/25 7 ml Thumb Ring Finger Ring Rotating Adaptor No H Box/25 8 ml Thumb Ring Finger Ring Fixed MLL Yes H Box/25 8 ml Thumb Ring Finger Ring Fixed MLL No H Box/25 8 ml Thumb Ring Finger Ring Rotating Adaptor Yes H Box/25 8 ml Thumb Ring Finger Ring Rotating Adaptor No H Box/25 10 ml Thumb Ring Finger Ring Fixed MLL Yes H Box/10 10 ml Thumb Ring Finger Ring Fixed MLL with 5 cm (2") Extension Yes H Box/10 10 ml Thumb Ring Finger Ring Rotating Adaptor Yes H Box/10 10 ml Thumb Ring Finger Grip Rotating Adaptor Yes H Box/10 10 ml Thumb Ring Finger Ring Extended RA Yes H Box/10 10 ml Palm Pad Finger Ring Fixed MLL Yes H Box/10 10 ml Palm Pad Finger Ring Rotating Adaptor Yes H Box/10 10 ml Palm Pad Finger Grip Rotating Adaptor Yes H Box/10 Contrast Management Systems As shown: H Squeeze Chamber Chamber w/ Green Ball One-Way Check Valves Tubing Length Tubing Type Stopcock Fitting Yes Yes Yes 183 cm (72") IV No No No Yes 183 cm (72 ) IV Yes Male/Male Luer Lock Male/Male Luer Lock H Box/ H Box/10 Angiographic Guidewires OD inch OD mm Length Tip Description Core Coating < cm 3 mm J Fixed PTFE H Box/ < cm 3 mm J Fixed PTFE H Box/ < cm 3 mm J Fixed PTFE H Box/ < cm 3 mm J Fixed PTFE H Box/ < cm 3 mm J Fixed PTFE H Box/10 Contrast Controller Spike Assembly Pressurized or Non-Pressurized Vented or Non-Vented Chamber or Spike Head Tubing Length Stopcock Fitting Convenience Kit Part Number Non-Pressurized Vented Spike Head 4 cm (1.5") 1-way Female H Box/25

6 Program By providing the NAMIC Dream Kit through our Convenience Kit program, you can tailor the accessories and components within the kit to meet your lab s needs and provide a full solution for your angiographic procedures. Contact your AngioDynamics NAMIC sales representative to make your dream kit a reality for your lab. Consult your AngioDynamics representative for country specific product availability. Distributed by Navilyst Medical Images may not represent actual products IMPORTANT RISK INFORMATION Refer to Directions for Use provided with products for indications, complete instructions, warnings, and precautions. NAMIC COMPENSATOR MANIFOLD INTENDED USE/INDICATIONS FOR USE: Physiological pressure transducers are utilized during invasive pressure monitoring, catheterization procedures and fluid delivery. WARNINGS: Do not exceed the following pressures when using this device - Main lumen: Medium Pressure Manifolds 1379 kpa (200 psi/14bar) Static pressure; High Pressure Manifolds 3447 kpa (500 psi/35 bar) Static pressure; Transducer Side Port 41 kpa (6 psi/300 mmhg). Do not use if package is opened or damaged. PRECAUTIONS: The Compensator line must be completely filled with saline to produce accurate pressure readings. The female luer end of the Compensator line (placed in a compatible mounting plate) must be at heart level in order to produce accurate readings. During fluid injection through the main lumen of the manifold, ensure proper orientation of the handles so that fluid does not enter the side ports. Do not use transducer Zero/Compensator Port as an injection site for fluids. NAMIC SQUEEZE CONTRAST CONTROLLER INTENDED USE/INDICATIONS FOR USE: The purpose of this system is to minimize contrast waste and allow one container of contrast media to be used on more than one patient. WARNINGS: Maintenance of sterility can only be achieved through proper set-up and use. Use proper aseptic technique when handling this device. Do not attempt to flush contrast media or air bubbles back through the contrast delivery system when the Squeeze Contrast Controller chamber is full of fluid. Flushing back through a full Squeeze chamber could damage the two check valves above the chamber and compromise the sterility of the spike assembly and contrast container. Do not use the spike assembly on more than one container of contrast media. Do not use the tubing assembly on more than one patient. Do not leave the spike assembly intact in a container of contrast for longer than six (6) hours. Do not replace the tubing assembly more than two (2) times. If there is any possibility that contamination may have occurred during set-up or use, disassemble and set up new sterile product. Ensure that you are making secure connections when using this device to prevent the introduction of air into the system that could result in embolism and in rare instances death. All connections should be finger tightened. Over tightening can cause cracks and leaks to occur that could result in embolism and or exposure to biohazards. Examine product carefully for entrapped air and fully debubble prior to injection to minimize the potential for embolism and in rare instances death. PRECAUTIONS: Carefully read these instructions completely prior to use. The chamber must hang vertically for the green ball to operate effectively. NAMIC ANGIOGRAPHIC CONTROL SYRINGE INTENDED USE/INDICATIONS FOR USE: The NAMIC Angiographic Control Syringe is intended to be used for the intraarterial or intravenous administration of radiographic contrast media. WARNINGS: Do not store fluid in product. Inject immediately after filling. This syringe does not have a pressure gauge device. Therefore, it is not intended for balloon catheter inflation. Over inflation may result in the rupturing of the balloon. NAMIC DEVICES: FLUID DELIVERY SETS, CONTRAST INJECTION LINES AND PRESSURE MONITORING LINES INTENDED USE/INDICATIONS FOR USE: These devices are intended to be used in fluid management and/or invasive pressure monitoring systems. NAMIC ANGIOGRAPHIC GUIDEWIRES INTENDED USE/INDICATIONS FOR USE: The Navilyst Medical Angiographic Guidewires are intended for use in percutaneous introduction of catheters. CAUTION: Federal Law (USA) restricts these devices to sale by or on the order of a physician. USA > 14 Plaza Drive, Latham, NY > tel: or > fax: International > Haaksbergweg 75 (Margriettoren), 1101 BR, Amsterdam Z-O > The Netherlands tel: +31 (0) > fax: +31 (0) Legal Manufacturer: Navilyst Medical, Inc. 26 Forest Street, Marlborough, MA AngioDynamics, the AngioDynamics logo, NAMIC, the NAMIC logo, Compensator, Squeeze, Acceler-8, flexcil and Navilyst Medical are trademarks and/or registered trademarks of AngioDynamics, Inc., and affiliate or subsidiary. May be covered by or for use under one or more of the following U.S. patents: 5,533,978; 5,779,666; 5,911,708 and foreign counterparts AngioDynamics, Inc. NAVB 410 Rev. 1 11/13

NAMIC Fluid Management

NAMIC Fluid Management NAMIC Fluid Management Flexibility, Quality and Choice Systems for Vascular and Radiology Labs Optimized System for Vascular and Radiology Labs Flexibility. Quality. Choice. Today s vascular and radiology

More information

Xcela Hybrid PICC. Clinician Reference Tool

Xcela Hybrid PICC. Clinician Reference Tool Xcela Hybrid PICC Clinician Reference Tool Xcela * Hybrid PICC Overview ew Three Lumens, Two Valves Two PASV * valved lumens designed to prevent blood reflux that could lead to catheter-related complications

More information

Disposable Transducers

Disposable Transducers Disposable Transducers 100% Tested. Advanced Technology. Accurate Results. NAMIC Perceptor * DT Disposable Transducers are designed specifically for use in cardiology and vascular procedures. The rigors

More information

DIAGNOSTIC CARDIOLOGY

DIAGNOSTIC CARDIOLOGY DIAGNOSTIC CARDIOLOGY For Your Procedural Needs Manufactured to the Highest Standards, Customised to Your Specific Needs MEDLINE PROCEDURE PACKS The items contained within this brochure are perfect for

More information

Critical Disposables. Non-Sterile Angiographic Accessories. for Medical Device Manufacturers & Kit Packers

Critical Disposables. Non-Sterile Angiographic Accessories. for Medical Device Manufacturers & Kit Packers Critical Disposables Non-Sterile Angiographic Accessories for Medical Device Manufacturers & Kit Packers Non-Sterile Angiographic Accessories DEROYAL PRODUCTS FOR CARDIOLOGY & ANGIOGRAPHY Whether it s

More information

INTERVENTIONAL CARDIOLOGY

INTERVENTIONAL CARDIOLOGY Y-Connector Newtech Y connector it is easy, fast and accurate single handed intra vascular device insertion. Perfect insertion device respecting the integrity of the coated surface with Combination of

More information

PRODUCT CATALOGUE OF

PRODUCT CATALOGUE OF PRODUCT CATALOGUE OF INTERVENTIONAL CARDIOLOGY AND GENERAL MEDICAL DISPOSABLES Table of Contents INFLATION DEVICE... 4 GUIDE WIRE (PTFE)... 5 MANIFOLD... 6 PTCA Y Connector... 7 INTRODUCER SHEATH (Femoral/

More information

SPECIALTY DEVICES YOUR SOURCE FOR SPECIALTY DEVICES

SPECIALTY DEVICES YOUR SOURCE FOR SPECIALTY DEVICES SPECIALTY DEVICES YOUR SOURCE FOR SPECIALTY DEVICES Snares The EN Snare Endovascular Snare System is intended for use in the cardiovascular system or hollow viscous to retrieve and manipulate foreign objects.

More information

Tridak Model 1050 User Guide

Tridak Model 1050 User Guide Tridak Model 1050 User Guide Syringe Filling System Instructions for Safe Use Setup and Operation Maintenance Ordering Spare Parts and Accessories 2 Tridak Model 1050 Syringe Filling System User Guide

More information

C O L O G Y. New. g u O N. l o t a C a. The high security connection

C O L O G Y. New. g u O N. l o t a C a. The high security connection O N g u e C O L O G Y New l o t a C a The high security connection Preparation devices for medications/solutions Bag qimospike B 7218.01 qimospike B is an IV fluid bag access spike fitted with qimo. Aspiration

More information

BIOCLOSURE SYSTEM ASSEMBLIES

BIOCLOSURE SYSTEM ASSEMBLIES TECH SHEET www.advantapure.com BioClosure System Assemblies, made from AdvantaFlex biopharmaceutical grade TPE, provide a ready to use, cost effective solution to reduce assembly time and eliminate cleaning

More information

Blood Pressure Monitoring: Arterial Line

Blood Pressure Monitoring: Arterial Line Approved by: Blood Pressure Monitoring: Arterial Line Gail Cameron Senior Director, Operations, Maternal, Neonatal & Child Health Programs Dr. Ensenat Medical Director, Neonatology Neonatal Nursery Policy

More information

Compatible Baxter IV Sets

Compatible Baxter IV Sets SIGMA Spectrum and Spectrum IQ Infusion System Compatible Baxter IV Sets (For use with SIGMA Spectrum and Spectrum IQ Infusion Pumps that have been calibrated for Baxter IV set tubing). NOTE: The superscript

More information

New. The high security connection

New. The high security connection L ON Cata C lo gu e O O G Y New The high security connection Preparation devices for medications/solutions Bag qimospike B 7218.01 qimospike B is an IV fluid bag access spike fitted with qimo. Aspiration

More information

PreludeSYNC. Radial Compression Device INSTRUCTIONS FOR USE

PreludeSYNC. Radial Compression Device INSTRUCTIONS FOR USE PreludeSYNC Radial Compression Device INSTRUCTIONS FOR USE PreludeSYNC Radial Compression Device English INSTRUCTIONS FOR USE PRODUCT DESCRIPTION The Prelude Sync Radial Compression Device is a sterile,

More information

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC Aseptic Techniques Techniques for Sterile Compounding Pharmacy Technician Training Systems Passassured, LLC Aseptic Techniques, Tech for Sterile Compounding PassAssured's Pharmacy Technician Training Program

More information

MyoSure Setup Simplified

MyoSure Setup Simplified MyoSure Setup Simplified This is designed as a quick reference guide only. This guide is not a substitute for the Operator s Manual and/or Instructions for Use (IFU). MyoSure Setup with Aquilex MyoSure

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S ) Page 1 of 27 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Advanced Intravenous Training Arm in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy

More information

MyControl Bathing System Signature Series

MyControl Bathing System Signature Series MyControl Bathing System Signature Series Touch Assist Touch Pad and CM Technologies Seal Pressure Regulation Instructions Acceptable seal inflation pressure setting must be varified, and adjusted if necessary,

More information

Varithena Delivery System Instructions for Use

Varithena Delivery System Instructions for Use Varithena Delivery System Instructions for Use Please read all prescribing information before using the product. The Instructions for Use are for the entire Varithena system. There are 2 packaging configurations:

More information

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax OPERATION MANUAL Zutron Medical, LLC 17501 W 98 th St #40-27 Lenexa, KS 66219 Phone 877-343-5873 Fax 913-967-5944 ZUT-Lab-004-30004 REV. 03312017 Table of Contents 2 Introduction 1. Intended Use 2. Labels,

More information

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION Application Note Doc. G8108-001 Rev. A - 23-Jul-02 ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION For more information regarding Digiquartz products contact: Paroscientific,

More information

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa CENTRAL IOWA HEALTHCARE Marshalltown, Iowa INTENSIVE CARE UNIT POLICY & PROCEDURE Policy Number: R-28/4.22 Subject: Purpose: Policy: Arterial Monitoring Use of intra-arterial pressure monitoring allows

More information

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care Clinician Guide Baxter Elastomeric Devices Promoting patient-centric care Portfolio Overview Portfolio Overview Baxter Elastomeric Devices are non-electronic medication devices designed to provide ambulatory

More information

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product. Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product. The Instructions for Use are for the entire Varithena TM system. There are

More information

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE CARE OF PATIENT WITH A GASTRIC-JEJUNAL FEEDING TUBE Some patients may benefit from the use of an enteral feeding tube that provides

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

RESPIRATORY HEALTH PRODUCTS

RESPIRATORY HEALTH PRODUCTS RESPIRATORY HEALTH PRODUCTS CONTENTS ADULT CLOSED SUCTION SYSTEMS HALYARD* CLOSED SUCTION SYSTEMS Double Swivel Elbows page 54 WET PAK* Double Swivel Elbows page 54 T-Pieces page 65 WET PAK* T-Pieces page

More information

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING ACQUIDATA FAMILY CALIBRATION PROCEDURE The calibration procedure for the Acquidata product family is very simple. No special calibration screen or recording phase needs to be selected. Simply open a new

More information

BD Cytopeia Fluidic Kit User s Guide

BD Cytopeia Fluidic Kit User s Guide BD Cytopeia Fluidic Kit User s Guide For Research Use Only 23-17618-00 9/2015 Becton, Dickinson and Company BD Biosciences 2350 Qume Drive San Jose, CA 95131 USA BD Biosciences European Customer Support

More information

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE DESCRIPTION A Heart/Lung Perfusion Pack is either a customized tubing pack built to user specifications or a stock tubing pack, designed for use during surgery

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

Research Grade Blood Pressure Transducer User's Manual

Research Grade Blood Pressure Transducer User's Manual Research Grade Blood Pressure Transducer User's Manual Research Grade Blood Pressure Transducer, 110 VAC/60 Hz MA1 60-3002 Research Grade Blood Pressure Transducer, 220 VAC/50 Hz MA1 60-3003 WEEE/RoHS

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Reference Guide. Correct Usage of EasySpray and Duplospray Pressure Regulator

Reference Guide. Correct Usage of EasySpray and Duplospray Pressure Regulator Reference Guide Correct Usage of EasySpray and Duplospray Pressure Regulator b EASYSPRAY and DUPLOSPRAY MI EASYSPRAY Pressure Regulator Operation (open surgery) 1 Insert 9V battery into the EASYSPRAY Pressure

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

Patients Guide for Self Administering Intravenous Antibiotics General points

Patients Guide for Self Administering Intravenous Antibiotics General points Patients Guide for Self Administering Intravenous Antibiotics General points An intravenous line is an open route for infection therefore you need to prevent this by washing your hands before any procedure

More information

Rev. B. Operating Instructions

Rev. B. Operating Instructions 780745-00 Rev. B Operating Instructions 780745-00 Rev. B TABLE OF CONTENTS PAGE Warnings, Cautions, and Notes..............................4-7 Definition of Symbols......................................

More information

BPS-2, Rev TABLE OF CONTENTS

BPS-2, Rev TABLE OF CONTENTS BPS-2, Rev. 050404 Bilayer Perfusion System Model BPS-2 125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 fax www.warneronline.com BPS-2, Rev. 050404 TABLE OF CONTENTS

More information

Making Life Easier Easypump II

Making Life Easier Easypump II Making Life Easier Easypump II The elastomeric pump system for short- and long-term infusion therapy Elastomeric Infusion Systems Technical Guide Easypump II Disposable Elastomeric Infusion Pump System

More information

RESPIRATORY HEALTH PRODUCTS

RESPIRATORY HEALTH PRODUCTS RESPIRATORY HEALTH PRODUCTS CONTENTS ADULT ENDOTRACHEAL TUBES HALYARD* MICROCUFF* ENDOTRACHEAL TUBES Oral/Nasal Magill page 4 HALYARD* MICROCUFF* SUBGLOTTIC SECRETION DRAINAGE ENDOTRACHEAL TUBE Subglottic

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

TJF-Q180V Cleaning and Disinfection Checklist

TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators Genstar Technologies Co., Inc. 4525 Edison Avenue Chino, CA 91710 USA TEL 909-0-272 FAX 909-0-485

More information

Santa Fe Cycles Assembly Guide Introduction

Santa Fe Cycles Assembly Guide Introduction Santa Fe Cycles Assembly Guide Introduction Congratulations on your purchase of your new Santa Fe bicycle. You have purchased a bicycle that has many features and qualities. Please take a few minutes and

More information

MARK III Manometric Perfusion Pump Ve rtical Deck

MARK III Manometric Perfusion Pump Ve rtical Deck MARK III Manometric Perfusion Pump Ve rtical Deck Dentsleeve International Ltd. Manufactured by Mui Scientific 45 Traders Blvd. East, Unit 33-34 Mississauga, Ontario, CANADA L4Z 3L3 Tel: (905) 7-888 Fax:

More information

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses VHP Tees & Crosses for Capillary Tubing VHP Tees & Crosses for 1/16 OD Tubing IDEX Health & Science offers Very High Pressure, designed to bring

More information

Training. Testor Training Manual

Training. Testor Training Manual Training Testor Training Manual Index Section 1 Introduction and Safety Warnings Section 2 Test Procedures Section 3 Test Hoses Section 4 Fault Location 1:1 1.1 Introduction The Dräger Testor test equipment

More information

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM THE INNOVATIVE SOLUTION for contrast media and saline injection in CT medical imaging Designed for MULTI-USE Dual soft bag injector for MONO & BI-LIQUID

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Tempe Pressure Cell June 1995 Fig. 1a 1400 Tempe Pressure Cells with 3cm cylinders and 6cm cylinders) mounted on the Tempe Cell Stand Fig. 1b Disassembled 1400 Tempe Pressure Cell

More information

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique. 1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique. 2.0 RESPONSIBILITY 2.1 It is the responsibility of each employee working in a laboratory setting to follow this

More information

TJF-Q180V Cleaning and Disinfection Checklist

TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

ARTERIAL MONITORING. Final Approval: VP Operations, Chief Nursing Officer Distribution: ICU, PACU POLICY:

ARTERIAL MONITORING. Final Approval: VP Operations, Chief Nursing Officer Distribution: ICU, PACU POLICY: Policy Number: R-28 / Care of Patient 4.22 Section: Intensive Care Date Written: June 1988 Date(s) Revised: 8/98, 6/01, 11/03 Date(s) Reviewed: 4/92, 12/93, 7/95, 6/04 Reviewed/Approved by: Dept.Cmt. Date

More information

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual OPERATORS ORS GUIDE REL-46 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with RELIABLE R15 and P Style dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 301 Ivyland Road Warminster, PA 18974

More information

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions and the instructions provided

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

ATS430 turbidity sensor Retractable insertion assembly

ATS430 turbidity sensor Retractable insertion assembly A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion

More information

Bubble Tube Installations

Bubble Tube Installations Instruction MI 020-328 September 2013 Bubble Tube Installations For Liquid Level, Density, and Interface Level Measurements 2 Contents Introduction... 5 Abbreviations... 5 Principle of Operation... 5 Alternative

More information

Domiciliary Oxygen Switch. Instructions for Use

Domiciliary Oxygen Switch. Instructions for Use Domiciliary Oxygen Switch Instructions for Use 702-0041.11 July 2017 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the

More information

Rejuvenation Instructions

Rejuvenation Instructions Rejuvenation Instructions #401 Air Systems UPR This NRI covers the following: Understanding the applications and operation of flow meters. Understand the application and operation of test pressure gauges.

More information

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400 COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400 Table of Contents 1 introduction...1 1.1 general product description...1 1.2 schematics...1 1.3 specifications...2 2 instrument

More information

Manual Solvent Purification System. Innovative Technology, Inc.

Manual Solvent Purification System. Innovative Technology, Inc. Innovative Technology, Inc. 2 New Pasture Road, Newburyport, MA 01950-4054 USA Email: Info@gloveboxes.com TEL: +1 978 462 4415 FAX: +1 978 462 3338 Manual Solvent Purification System Copyright Innovative

More information

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL DO NOT REMOVE FILM FROM TUBING! THIS PRODUCT CONTAINS DRY NATURAL RUBBER! Products by NASCO About the Simulator The Life/form Pediatric

More information

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References User Guide Pall Laboratory Manifold For laboratory use. Not for use in a manner other than indicated. Introduction Application and Intended Use The membrane filtration (MF) technique is a method of analyzing

More information

Parts identification:

Parts identification: ARTERY PUNCTURE AND INTRAMUSCULAR TRAINING ARM Parts identification: FAST-derm replacement skin (removable) Intramuscular injection pad (removable for cleaning) Training arm (includes one FAST-derm replacement

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

Models: C62/63/64-A/D

Models: C62/63/64-A/D Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial

More information

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP NURSING PROCEDURE TITLE ARTERIAL BLOOD SAMPLING (NEONATAL) A. Umbilical Catheter Blood Collection B. Radial Arterial Line CATEGORY: RN - SNP PURPOSE To obtain blood samples for laboratory analysis NURSING

More information

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency Demonstrates an understanding of why RCA has been prescribed Explain the anticoagulation protocol Demonstrate an understanding of potential complications associated with CRRT. Explain potential indications

More information

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132 Paintball Marker User s Manual 530 South Springbrook Road Newberg, OR 97132 Component Concepts, Inc., 530 South Springbrook Road, Newberg, OR 97132 Phone: (503) 554-8095 Fax: (503) 554-9370 www.phantomonline.com

More information

GI Series Diaphragm Pressure Gauge Guard

GI Series Diaphragm Pressure Gauge Guard Diaphragm Pressure Gauge Guard INSTRUCTION MANUAL Please read this Instruction Manual Carefully and Thoroughly for the Correct and Optimum use of this Product. Kindly keep this manual in a convenient place

More information

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400 COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400 Table of Contents 1 introduction...1 1.1 general product description... 1 1.2 schematics...1 1.3 specifications... 2 2 instrument

More information

Safety Huber Needles

Safety Huber Needles Safety Huber Needles Huber needles are used to administer chemotherapy, antibiotics, and TPN through an implanted IV port. These needles may be left in the port for many days at a time. It can be difficult

More information

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy.

V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy. V-Green Protect-A-Line A range of drug-compatible extension lines designed to enhance patient safety during IV therapy. 70.832.01, 70.832.211 70.832.04 Anti-Syphon Valve ASV Minimises the risk of downloading

More information

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides Specialty Neonatal/Pediatric Safety Infusion Sets Anti-Reflux Technology Provides Blood Reflux Protection 24/7! NEXUS TKO TECHNOLOGY THAT NEVER SLEEPS! Nexus TKO Neonatal Safety Catheter Nexus Tri-Seal

More information

Masoneilan* 78 Model Air Filter Regulator

Masoneilan* 78 Model Air Filter Regulator GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel:

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel: WE CARE ACCURATELY ACCURA Medizintechnik GmbH Max-Planck-Straße 33-61184 Karben / Germany Tel: +49 6039 92010 Email: info@accuramed.de WELCOME TO ACCURA About ACCURA ACCURA Medizintechnik GmbH supplies

More information

D05T Compact Design Pressure Regulating Valves

D05T Compact Design Pressure Regulating Valves D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.

More information

Constant Pressure Crude Oil Container Model CPCCP

Constant Pressure Crude Oil Container Model CPCCP Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd. User Guide Advanced Venepuncture Arm Product No: 00290 (Light) Product No: 00298 (Brown) For more skills training products visit limbsandthings.com Limbs & Things Ltd. Sussex Street, St Philips Bristol,

More information

A complete family of Pediatric Perfusion Systems

A complete family of Pediatric Perfusion Systems LEADING THE FIELD OF PEDIATRIC PERFUSION FOR OVER 25 YEARS A complete family of Pediatric Perfusion Systems Perfusion systems designed for the broadest range of pediatric patients Small, sensitive neonatal

More information

Solvent System Walkthrough

Solvent System Walkthrough v2.0 1 Solvent System Walkthrough The Contour Glass solvent system is designed to give you air-free anhydrous solvent with minimal effort. However, the system is only as good as its users so please read

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual Keofitt Aseptic Sampling Bag (Pat. pend.) Item no. 120500, 121000 & 122000 User Manual s o m e p e o p l e w o u l d n t g a m B l e w i t h t h e i r s a m p l e t m Introduction: Manufacturer: Keofitt

More information

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no. 120500, 121000 & 122000 User Manual S O M E P E O P L E W O U L D N T G A M B L E W I T H T H E I R S A M P L E T M INTRODUCTION: MANUFACTURER: Keofitt

More information

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists TITLE/DESCRIPTION: DEPARTMENT: PERSONNEL: 1.060 Set-Up and Priming of the Bypass Circuit Perfusion Technology Department Perfusionists EFFECTIVE DATE: 8/97 REVISED: 09/07, 04/09, 9/17 PURPOSE: The function

More information

Instruction for Use of Balloon Inflator JS-CE-SM-12-01, A/0

Instruction for Use of Balloon Inflator JS-CE-SM-12-01, A/0 Instruction for Use of Balloon Inflator JS-CE-SM-12-01, A/0 Instruction for Use of Balloon Inflator Product name Balloon Inflator Product structure and components The Balloon Inflator can be divided into

More information

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008

More information

Tourniquet Systems Pressure Infusion

Tourniquet Systems Pressure Infusion Tourniquet Systems Pressure Infusion VBM Medizintechnik GmbH VBM 1 VBM 2 Summary Tourniquets and Accessories Digital Tourniquets... Compressed Air Tourniquets... Electronic Tourniquets... Application Tourniquets...

More information

Pitfalls & Practical Tips

Pitfalls & Practical Tips Pitfalls & Practical Tips Pitfalls & Practical Tips Transducer Height and AO Pressure Equalization Guidewire Introducer Needles Guide Catheter (wedging, damping & side holes) PressureWire Drift Artifacts

More information

Model 10. Low-Medium Pressure Reducing Regulator

Model 10. Low-Medium Pressure Reducing Regulator Model 10 Low-Medium Pressure Reducing Regulator General Specifications & Performance Characteristics The Model 10 is a pressure reducing regulator useful in a wide variety of applications. The Model 10

More information