1 Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for a high level of enclosure, robust and compact construction, and resistance to shock and vibration. For KPS pressure switches the position of the contacts depends on the pressure in the inlet connection and the set scale value. For KPS thermostats the position of the contacts depends on the temperature of the sensor and the set scale value. The series covers most outdoor as well as indoor application requirements and is suitable for use in monitoring alarm and control systems in factories, diesel plants, compressors, power stations and on board ships. Features A high level of enclosure Adjustable differential Robust and compact construction Resistance to shock and vibration Available with all major marine approvals Approvals CE-marked in accordance with: LVD 2014/35/EU (EN , EN , EN ) Underwriters Laboratories Inc., US-UL (excluding KPS 39) China Compulsory Certificate, CCC Ship approvals American Bureau of Shipping, ABS Det Norske Veritas, DNV Germanischer Lloyd, GL Registro Italiano Navale, RINA (KPS 43, KPS 45, KPS 47, KPS 76, KPS 77, KPS 79, KPS 80, KPS 81, KPS 83) Maritime Register of Shipping, RMRS Nippon Kaiji Kyokai, NKK (KPS 31, KPS 33, KPS 35, KPS 37, KPS 39, KPS 43, KPS 45, KPS 47) China Classification Society, CCS Bureau Veritas, BV Korean Register of Shipping, KR (KPS 35, KPS 37, KPS 39, KPS 43, KPS 45, KPS 47) Lloyds Register of Shipping, LR Danfoss DCS (jmn) IC.PD.P10.I B7620 1
2 Overview 1. Standard pressure switches Range P e Type Further information page KPS KPS KPS KPS KPS Pressure switches for high pressure and strongly pulsating media Range P e Type Further information page 1 10 KPS KPS KPS Thermostats [ C] Range P e Type [ C] Further information page KPS KPS KPS KPS KPS KPS Danfoss DCS (jmn) IC.PD.P10.I B7620 2
3 PRESSURE SWITCH Technical data and ordering KPS 31, KPS 33 KPS 35, KPS 37, KPS Pressure switches Type Setting range P e Adjustable/ fixed differetial Permissible operating pressure P e Max. test pressure Pressure connection Code no. KPS G 1 / KPS G 3 / 8 A KPS G 1 / KPS G 3 / 8 A KPS G 1 / KPS G 3 / 8 A KPS G 1 / KPS G 1 / KPS G 3 / 8 A KPS G 1 / KPS G 3 / 8 A Pressure switches for high pressure and strongly pulsating media Type Setting range P e Adjustable diff. see also figs. 1, 2, and 3 Permissible overpressure Max. test pressure Min. burst pressure Pressure connection Code no. KPS 43, KPS 45, KPS 47 When ordering, please state type and code number KPS G 1 / KPS G 1 / KPS G 1 / Terminology Range setting The pressure range within which the unit will give a signal (contact changeover). Differential The difference between make pressure and break pressure (see also fig. 5 & 6, page 6). Permissible overpressure The highest permanent or recuiring pressure the unit can be loaded with. Max. test pressure The highest pressure the unit may be subjected to when, for example, testing the system for leakage. Therefore, this pressure must not occur as a recurring system pressure. Min. bursting pressure The pressure which the pressure-sensitive element will withstand without leaking. Danfoss DCS (jmn) IC.PD.P10.I B7620 3
4 Technical data and ordering (continued) Switch Single pole changeover (SPDT) Contact material: Gold-plated silver contact Contact load (when Au surface is burnt away) Ambient temperature Alternating current Ohmic Inductive Starting current 10 A, 440 V, AC-1 6 A, 440 V, AC-3 4 A, 440 V, AC-15 max. 50 A (locked rotor) Direct current 12 W, 220 V, DC-13, see curve, fig. 4, page 5 KPS C KPS C Temperature of medium 1) KPS C KPS C Vibration resistance Vibration-stable in the range 2 30 Hz, amplitude 1.1 mm og Hz, 4 g. Enclosure IP67 (including IPX6) according to EN The pressure switch housing is enamelled pressure die cast aluminium (GD-AlSi 12). The cover is fastened by four screws which are anchored to prevent loss. The enclosure can be sealed with wire. Cable entry Pg 13.5 for cable diameters from 5 14 mm. Identification The type designation and code no. of the unit is stamped in the side of the housing. 1) For water and seawater, max. 80 C. Types Scale accuracy Mean value of snap point variation after operations KPS 31 ±0.2 ±0.1 KPS 33 ±0.3 ±0.2 KPS 35 ±0.5 ±0.3 KPS 37 ±1.0 ±0.4 KPS 39 ±3.0 ±0.7 KPS 43 ±1.0 ±0.2 KPS 45 ±4.0 ±1.0 KPS 47 ±6.0 ±1.5 Materials in contact with the medium Type KPS 31, KPS 33 KPS 35, KPS 37, KPS 39 KPS 43, KPS 45, KPS 47 Materials Bellows capsule Deep-drawn plate, material no (DIN 1624) Bellows Stainless steel, material no (DIN 17440) Pressure connection Steel C20, material no (DIN 1652) Bellows Stainless steel, material no (DIN 17440) Pressure connection Brass, W. no (DIN 17660) Diaphragm capsule Nickel-plated brass, DIN Cu/Ni 5 (DIN 1756) Diaphragm Nitrile-Butadien rubber Danfoss DCS (jmn) IC.PD.P10.I B7620 4
5 Technical data and ordering (continued) KPS 43 KPS 45 A B C A B C Danfoss Danfoss Fig. 1 Fig. 2 KPS 47 A B C A: Range setting B: Differential scale C: Obtained differential Fig. 3 Danfoss Direct current (DC) -load [ma] 12 W A [V] Curve A: gives the maximum load Fig. 4 Hatched area B: Acceptable load for the gold plating of the contact Danfoss DCS (jmn) IC.PD.P10.I B7620 5
6 Function 1. KPS 31 Contacts 1-2 make and contacts 1-4 break when the pressure falls under the set range value. The contacts changeover to their initial position when the pressure again rises to the set range value plus the differential (see fig. 5). I. Alarm for falling pressure given at the set range value II. Alarm for rising pressure given at the set range value plus the differential. Fig. 5 [s] Scale setting Mechanical differential 2. All other KPS pressure SWITCHES Contacts 1-4 make and contacts 1-2 break when the pressure rises above the set range value. The contacts changeover to their initial position when the pressure again fails to the range value minus the differential (see fig. 6). I. Alarm for rising pressure given at the set range value II. Alarm for falling pressure given at the set range value minus the differential Fig. 6 [s] Scale setting Mechanical differential Danfoss DCS (jmn) IC.PD.P10.I B7620 6
7 Function KPS 45 (continued) Example 2 An alarm must be given by a bell when the pressure in a boiler rises to 10 bar. The normal operating pressure is 9 bar. Choose a KPS 37 (range 6 18 bar). The range value of the pressure switch must be set at 10 bar, the differential at 1 bar. A B C The bell must be connected to terminals 1 and 4. Example 3 The pressure in a start air reservoir must be regulated with a compressor controlled by a KPS pressure switch so that it lies between 30 and 36 bar. Choose a KPS 45 (range 4 40 bar). The range value must be set at 36 bar. Fig. 7 The differential of 6 bar must be set in accordance with the nomogram, fig. 7, at approx. 2 on the differential scale. The required start function is obtained by connection to terminals 1 and 2 in the pressure switch. Danfoss Example 1 An alarm must be given when the lubricating oil pressure in an engine falls below 0.8 bar. The alarm is in the form of a lamp. Choose a KPS 31 (range bar). The minimum permissible lubricating oil pressure of 0.8 bar must be set on the range spindle. The differential is fixed at 0.1 bar, i.e. the alarm will not cut out before the pressure rises to 0.9 bar. The lamp must be connected to terminals 1 and 2 in the pressure switch. Danfoss DCS (jmn) IC.PD.P10.I B7620 7
8 Dimensions [mm] and weights [kg] Net weight: KPS approx. 1.0 kg KPS approx. 1.3 kg KPS 31, KPS 33 KPS 35, KPS 37, KPS 39 KPS 43, KPS 45, KPS 47 Danfoss DCS (jmn) IC.PD.P10.I B7620 8
9 Accessories Part Description Code no. Connector with nipple G 3 / 8 connector, nipple and washer (10 mm o.d. 6.5 mm i.d.) for brazing Connector with nipple G 3 / 8 connector, nipple and washer (10 mm o.d. 6.5 mm i.d.) for welding Reducer Danfoss G 3 / 8 7 / UNF ( 1 / 4 flare) reduction with washer Adapter G 3 / 8 1 / 8 27 NPT with washer Nipple G 3 / 8 o.d 7 / UNF ( 1 / 4 flare) Nipple G 3 / 8 A 1 / 4 NPT with washer Adapter G 3 / 8 1 / 4 18 NPT with washer Nipple G 1 / 4 A G 3 / 8 A G 1 / 4 A x o.d. M10 1 with washer Damping coil Danfoss Damping coil with 1 / 4 flare connectors and 1 m copper capillary tube. Damping coils used for applications with 3 / 8 RG connector requires the use of reducer. For informations about capillary tube lengths, please contact Danfoss Danfoss Damping coil Damping coil with G 3 / 8 connectors and 1.5 m copper capillary tube Armoured damping coil Damping coil with G 3 / 8 connectors and 1 m armoured copper capillary tube. Standard washers included Danfoss DCS (jmn) IC.PD.P10.I B7620 9
10 Installation Fig. 9 Fig Range spindle 2. Range scale 3. Differential spindle 4. Differential scale 5. Locking screw Installation KPS pressure switches are fitted with a 3 mm steel mounting plate. The units should not be allowed to hang from the pressure connection. Pressure connection When fitting or removing pressure lines, the spanner flats on the pressure connection should be used to apply counter-torque. Steam plant To protect the pressure element from excessive heat, the insertion of a water-filled loop is recommended. The loop can, for example, be made of 10 mm copper tube as shown in fig. 8. Water systems Water in the pressure element is not harmful, but if frost is likely to occur a water-filled pressure element may burst. To prevent this happening, the pressure control can be allowed to operate on an air cushion. Media-resistance See table of materials in contact with the medium, page 4. If seawater is involved, types KPS 43, KPS 45, KPS 47 are recommended. Pulsations If the pressure medium is superimposed with severe pulsations, which occur in automatic sprinkler systems (fire protection), fuel systems for diesel motors (priming lines), and hydraulic systems (e.g. propeller systems), etc., types KPS 43, KPS 45, KPS 47 are recommended. The maximum permissible pulsation level for these types is 120 bar. Setting When the pressure switch cover is removed, and the locking screw (5) is loosened, the range can be set with the spindle (1) while at the same time the scale (2) is being read. In units having an adjustable differential, the spindle (3) must be used to make the adjustment. The differential obtained can be read direct on the scale (4) or, with types KPS 43, KPS 45, KPS 47, can be determined by reading the scale value and using the nomograms in figs. 1, 2, 3 (page 5). The working line for determining the differential must not intersect the shaded areas in the nomograms. Selection of differential To ensure that the plant functions properly, a suitable differential pressure is necessary. Too small a differential will give rise to short running periods with a risk of hunting. Too high a differential will result in large pressure oscillations. Electrical connection KPS pressure switches are fitted with a Pg 13.5 screwed cable entry that is suitable for cable diameters from 5 14 mm. Contact function is shown in fig. 10. Fig. 10 Danfoss DCS (jmn) IC.PD.P10.I B
11 THERMOSTAT Technical data and ordering Type Setting range P e Mech. diff. adjustable/ fixed Max. sensor temp. Suitable sensor pocket length see also Accessories Cap. tube length Code no. [ C] [ C] [ C] [mm] [m] KPS L L KPS L KPS L KPS L KPS L L KPS with rigid sensor KPS L KPS L KPS L KPS L KPS L L KPS L KPS L KPS L KPS L KPS with remote sensor KPS L KPS L KPS L KPS L L KPS L KPS L KPS L KPS L L KPS with remote sensor and armoured capillary tube KPS L KPS L KPS L When ordering, please state type and code number KPS L L KPS L ) Electrical connection KPS thermostats are fitted with a Pg 13.5 screwed cable entry suitable for cables from 5 14 mm. Contact function is shown in fig. 11 Fig. 11 Danfoss DCS (jmn) IC.PD.P10.I B
12 Technical data Switch Single pole changeover (SPDT) Contact material: Gold-plated silver contact Ohmic 10 A, 440 V, AC-1 Contact load (when Au surface is burnt away) Alternating current Ambient temperature C Inductive Starting current 6 A, 440 V, AC-3 4 A, 440 V, AC-15 Direct current 12 W, 220 V, DC-13, see fig. 12 max. 50 A (locked rotor) Vibration resistance Vibration-stable in the range 2 30 Hz, amplitude 1.1 mm og Hz, 4 G. Enclosure Cable entry Identification IP67 to EN / IEC The thermostat housing is enamelled pressure die cast aluminium (GID-AlSI 12). The cover is fastened by four screws which are anchored to prevent loss. The enclosure can be sealed with fuse wire. Pg 13.5 for cable diameters from 5 14 mm. The type designation and code no. of the unit is stamped in the side of the housing. Types Scale accuracy *) [ C] Snap point variation after operations KPS 76 ±3 max. drift 2 KPS 77 ±3 max. drift 2 KPS 79 ±3 max. drift 2 KPS 80 ±3 max. drift 2 KPS 81 ±6 max. drift 2 KPS 83 ±6 max. drift 2 *) Scale values are indicative only. Results given in table are measured in laboratory conditions for factory set values (scale center). The scale accuracy for min and max positions could differ significantly. There are many factors which could influence on product working and scale accuracy. [ C] Direct current (DC) -load [ma] 12 W A B [V] Curve A: gives the maximum load Fig. 12 Hatched area B: Acceptable load for the gold plating of the contact Danfoss DCS (jmn) IC.PD.P10.I B
13 Function Selection of differential To ensure that the plant functions properly, a suitable differential is necessary. Too small a differential will give rise to short running periods with a risk of hunting. Too high a differential will result in large temperature variations. Differentials The mechanical differential is the differential that is set by the differential spindle in the temperature control. The thermal differential (operating differential) is the differential the system operates on. The thermal differential is always greater than the mechanical differential and depends on three factors: 1) the flow velocity of the medium, 2) the temperature change rate of the medium, 3) the heat transmission to the sensor. Thermostat function Contacts 1-4 make while contacts 1-2 break when the temperature rises above the scale setting. The contacts changeover to their initial position when the temperature falls to the scale setting minus the differential. See fig. 13. I. Alarm for rising pressure given at the set range value II. Alarm for falling pressure given at the set range value minus the differential Fig. 13 [s] Scale setting Mechanical differential Danfoss DCS (jmn) IC.PD.P10.I B
14 Dimensions [mm] and weights [kg] KPS with remote sensor KPS with remote sensor and armoured capillary tube Net weight: ca 1.2 kg (incl. 2 m capillary tube) Net weight: ca 1.4 kg (incl. 2 m capillary tube) KPS with rigid sensor ø3 ø13 Net weight: ca 1.0 kg Sensor pocket length A Sensor length L Danfoss DCS (jmn) IC.PD.P10.I B
15 Accessories Supplied without gland nut, gaskets and washer Sensor pockets for KPS thermostats Brass sensor pocket A [mm] B Thread Code no. A [mm] Steel 18/8 sensor pocket B Thread Code no / 2 NPT 060L / 2 NPT 060L G 1 / 2 A 060L G 1 / 2 A 060L G 3 / 4 A 060L G 1 / 2 A (ISO 228/1) 060L / 2 NPT 060L G 1 / 2 A 060L G 1 / 2 A 060L / 2 NPT 060L G 1 / 2 A (ISO 228/1) 060L G 3 / 4 A (ISO 228/1) 060L G 1 / 2 A 060L G 1 / 2 A 060L G 1 / 2 A 060L G 1 / 2 A (ISO 228/1) 060L G 1 / 2 A 060L G 1 / 2 A 060L Part Description Code no. Clamping band For KPS thermostats with remote sensor (L = 392 mm) WHeat-conductive compound (4.5 cm 2 tube) For KPS thermostats with sensor fitted in a sensor pocket. Compound for filling sensor pocket to improve heat transfer between pocket and sensor. Application range for compound: between pocket and sensor. Application range for compound: C, momentarily up to 220 C. 041E0114 Gasket set For KPS thermostats without armoured capillary tubes 060L Gasket set For KPS thermostats with armoured capillary tubes 060L Danfoss DCS (jmn) IC.PD.P10.I B
16 Installation Installation Location of unit: KPS thermostats are designed to withstand the shocks that occur, e.g. in ships, on compressors and in large machine installations. KPS thermostats with remote sensor are fitted with a base of 3 mm steel plate for fixing to bulkheads, etc. KPS thermostats with bulb sensor are self-supporting from the sensor pocket. Resistance to media Material specifications for sensor pockets: Sensor pocket, brass The tube is made of Ms 72 to DIN 17660, the threaded portion of So Ms 58Pb to DIN Sensor pocket, stainless steel 18/8 Material designation to DIN Sensor position As far as possible the sensor should be positioned so that its longitudinal axis is at right angles to the direction of flow. The active part of the sensor is ø13 mm 50 mm long on thermostats with rigid sensors and 2 m capillary tube. The active length on the other thermostats is 70 mm (5 m and 8 m capillary tubes). The medium The fastest reaction is obtained from a medium having high specific heat and high thermal conductivity. It is therefore advantageous to use a medium that fulfills these conditions (provided there is a choice). Flow velocity of the medium is also of significance. (The optimum flow velocity for liquids is about 0.3 m/s). For permissible media pressure see fig. 14. Permissible media pressure on the sensor pocket as a function of temperature Brass Stainless steel [ C] Fig. 14 Setting When the thermostat cover is removed, and the locking screw (5, fig. 15) is loosened, the range can be set with the spindle (1) while at the same time the scale (2) is being read. In units having an adjustable differential, the spindle (3) can be used while the scale (4) is being read. Fig Range spindle 2. Range scale 3. Differential spindle 4. Differential scale 5. Locking screw Danfoss DCS (jmn) IC.PD.P10.I B
17 Installation (continued) Scale correction The sensor on KPS thermostats contains an adsorption charge. Therefore function is not affected whether the sensor is placed warmer or colder than the remaining part of the thermostatic element (bellows and capillary tube). However, such a charge is to some extent sensitive to changes in the temperature and bellows and capillary tube. Under normal conditions this is of no importance, but if the temperature control is to be used in extreme ambient temperatures there will be a scale deviation. The deviation can be compensated for as follows: Scale correction = Z a Z can be found from fig. 16, while a is the correction factor from the table below. Factor for setting point deviation Danfoss Relative scale setting in [%] Fig. 16 Type Regulation range Correction factor a for thermostats [ C] with rigid sensor with 2 and 5 m cap. tube with 8 m cap. tube KPS KPS KPS KPS KPS KPS Danfoss DCS (jmn) IC.PD.P10.I B
18 Examples Example 1 A diesel engine with cooling water temperature of 85 C (normal). An alarm must be triggered if the cooling water temperature exceeds 95 C. Choose a KPS 80 thermostat (range C). Main spindle setting: 95 C. Differential spindle setting: 5 C. The required alarm function is obtained by connecting to thermostat terminals 1-4. After the system has been in operation, assess the operating differential and make a correction if necessary. Example 2 Find the necessary scale correction for a KPS 80 set at 95 C in 50 C ambient temperature. The relative scale setting Z can be calculated from the following formula: Setting value-min. scale value max. scale value-min. scale value Relative scale setting: = % 100 = 50% Factor for scale deviation Z (fig. 16 page 17), Z 0.7 Correction factor a (table under fig. 16 page 17) = 2.4 Scale correction = Z a = = 1.7 C The KPS must be set at = 96.7 C Danfoss DCS (jmn) IC.PD.P10.I B
Types and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
DSL, DSH: Specially designed pressure limiter
Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching
Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et
Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials
Pressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
JUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
Mechanical pressure switches
18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint
9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
Electromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
Position switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
Evaporator pressure regulator Type KVP
Data sheet Evaporator pressure regulator KVP The KVP is mounted in the suction line after the evaporator and is used to:. Maintain a constant evaporating pressure and thereby a constant surface temperature
Evaporator pressure regulator Type KVP
Data sheet Evaporator pressure regulator KVP The KVP is mounted in the suction line after the evaporator and is used to:. Maintain a constant evaporating pressure and thereby a constant surface temperature
Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
Differential pressure control and flow limiter AVPB/AVPB-F, PN 16
Data sheet Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Application AVPB is a self-acting differential pressure control and flow limiter primarily for use in district heating systems.
XML Electromechanical Pressure Switches
Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:
Liquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
GM-7000 Series CE Approved Gas Control Valve
Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
Expert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
Solenoid valve type EVR for Hydrocarbons
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and
Inverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
Seated valves VRB 3, VRG 3
Data sheet Seated valves VRB 3, VRG 3 Description VRB, VRG valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol concentrations
How to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
INSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
Pressure & Temperature Switches
Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase
Gas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
V146 Series 2-Way Pressure-Actuated Water-Regulating Valves
roduct/technical Bulletin V146 Issue Date November 20, 2002 V146 Series 2-Way ressure-actuated Water-Regulating s The V146 Series 2-Way ressure-actuated Water-Regulating s regulate water flow and control
Level transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
Solenoid Valves, one - or two step, on/off ICLX
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid Valves, one - or two step, on/off ICLX 32-150 ICLX servo valves belong to the ICV (Industrial Control Valve) family. ICLX are used in suction lines
Pressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
Relative pressure switch type 521
Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is
TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
Climatic Independent Level Sensor LAR
3 JAHRE GEWÄHRLEISTUNG SENSORS FOR FOOD AND BIOPHARMA. Product Information LAR-361 LAR-761 FOOD Climatic Independent Level Sensor LAR Application / Specified usage Hydrostatic level measurement in humid
MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
pipe connectors. General description of pipe connectors Development/Design Purpose Versions
Pipe connectors General description of pipe connectors 1 STFLEX pipe connectors, just like STFLEX rubber expansion joints, have been used for more than years as the preferred connection elements in appliance
Automatic balancing valves ASV
Automatic balancing valves ASV ASV-PV ASV-PV ASV-PV ASV-BD ASV-M DN 15-40 DN 50 DN 65-100 DN 15-50 DN 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating
Digital pressure gauge Model CPG500
Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make
Valve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h
Thermal Mass Flowmeter for compressed air and gases measuring monitoring analysing KMT Measuring range: 0.32... 63 Nm³/h - 263.4... 263350 Nm³/h Accuracy: ± 1.5% of reading + 0.5% of full scale ( DN 50)
Regulating valves REG-SA and REG-SB
MAKING MODERN LIVING POSSIBLE Technical brochure Regulating valves REG-SA and REG-SB REG-SA and REG-SB are angleway and straightway hand regulating valves, which act as normal stop valves in closed position.
Relative and differential pressure transmitter type 692
Relative and differential pressure transmitter type 692 Pressure range 0... 0.1 25 bar Type 692 pressure transmitters have a unique, well proven ceramic technolgy. There are variety of pressure and electrical
Installation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
Pressure independent balancing and control valve AB-QM DN
Data sheet Pressure independent balancing and control valve AB-QM DN 10-250 The AB-QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.
Hydraulic pressure balance Model CPB5800
Calibration technology Hydraulic pressure balance Model CPB5800 WIKA data sheet CT 31.11 for further approvals see page 8 Applications Primary standard for calibrating the pressure scale in a hydraulic
G92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
Programmable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
Pressure Switch Pressure Limiter
Assembly and Operating Instructions Pressure Switch Pressure Limiter Basic models Additional functions DCM......-203 DNM......-205 DNS......-206 VCM...,VNM......-307 VNS......-213 Important safety information!
(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD
The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075
Centriflow Plus High-pressure plug fan - Technical Data
Centriflow Plus 3 High-pressure plug fan - Technical Data Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Fan Inlet...5 base with base frame...5 Hub...5 Air
BGA158, BGA171 and BGA110 Series Shutoff Gas Valve
Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that
SIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
Gas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
North American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
GM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
SCH. Mechanical Pressure Switches. for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure measuring monitoring analysing SCH P3 OO Switching range: -1... + 0.1 bar - 250... +100 mbar, 1... 16 mbar a 16...
Spare parts list ( ) Spare parts list HDS 990
Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
PRESSURE, VACUUM AND TEMPERATURE
5 4 S er i es 5 4 Se r i e s PRESSURE, VACUUM AND TEMPERATURE features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90
Programmable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
Capacity regulator (hot gas bypass)
MAKING MODERN LIVING POSSIBLE Capacity regulator (hot gas bypass) TUH/TCHE/ Technical brochure Contents Page Introduction........................................................................................3
Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level glasses, type LLG 185-1550 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction LLG are liquid level glasses in ductile steel which meets the strictest requirements on industrial
Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters
Product Data Sheet Mobrey 9700 Transmitter Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty 4 20
INTERLOCKED METAL HOSE
INTERLOCKED METAL HOSE HOSE FUNDAMENTALS Penflex interlocked metal hoses are made for a variety of specialized industrial applications and are available in a wide range of metals, styles and sizes. Interlocked
OPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
BGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide
GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
Dival 600. Pressure Regulators
Dival 600 Pressure Regulators Pressure regulators Dival 600 Dival 600 series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter
Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
EXPLOSION-PROOF PRESSURE, VACUUM,
EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE, TEMPERATURE SWITCHES 120 Series FEATURES Class I, Div. 1 & 2, (Zone 1) Class II, Div. 1 & 2 Class III Worldwide approvals and certifications Choice
UNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
Safety Shut-Off Valve HON 720
Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable
P900. P900, Datenblatt Seite 1 DESCRIPTION
, Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and
WaterSource Heat Pump Hose Kit Performance Specification-Summary
WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo
3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.
027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
safety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY
CROSBY Table of contents 1. Installation 1 1.1. Drainage 1 1.2. Discharge pipework 1 1.3. Preparation for installation 1 2. Pressure adjustment 1 3. Maintenance 1 4. Dismantling 1 4.1. All valve types
SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION
SV/614 Installation Manual -P/N 80128 - Ed. 01/08 SV-(DLE) 10../614 Safety Shutoff Valve with Proof of Closure Installation Instructions 1 6 SV/614 SV-DLE/614 SPECIFICATIONS Normally closed automatic shutoff
BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
Air Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
MANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
Model GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
Zelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
GENERAL APPLICATION NOTES
GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in
The "BETA AIR RELAY"
SP251.C 1/9 The "BETA AIR RELAY" The pressure operated AIR RELAY Specially designed for: Valve Control Offshore & Onshore Zone 0 applications Products and specifications are liable to be changed without