1 Texas Chemical Council Environmental, Health & Safety Seminar Moody Gardens Convention Center Galveston, Texas TIPS FOR PREPARING FOR YOUR OSHA PSM INSPECTION June 5, 2013 Mark S. Dreux, Esq. Arent Fox LLP 1717 K Street, N.W. Washington, D.C (o) (c) mark.dreux@arentfox.com Mark S. Dreux

2 OVERVIEW CONGRESSIONAL HEARINGS CRITICIZING OSHA OSHA S RESPONSE TO CRITICISM TWO NEP S WEST FERTILIZER REFINING NEP ENFORCEMENT STATISTICS CHEMICAL NEP Overview Chemical NEP Enforcement Statistics LESSONS LEARNED FROM PSM CITATION PATTERNS INDUSTRY STANDARDS CITED MOST FREQUENTLY OSHA INTERPRETATION LETTER ON THRESHOLD QUANTITIES RECOMMENDATIONS 2

3 CONGRESSIONAL HEARINGS ON BP DISASTER MARCH 22, 2007 Chairman Miller Is OSHA doing its job? OSHA has failed to protect workers BP is the story of the failure of OSHA OSHA s penalty structure is ineffective Congressman Holt OSHA is the lap dog of the industry 3

4 KEY WITNESS AT THE CONGRESSIONAL HEARINGS Carolyn Meritt Chairperson of CSB OSHA s regulatory oversight was ineffective Rigorous enforcement of PSM would have prevented this incident OSHA has few trained inspectors. All witnesses agreed Chemical Industry and Refining Industry have similar safety issues. 4

5 OSHA S RESPONSE TO THE CRITICISM Two National Emphasis Programs Released in June 2007 Refining NEP Released in July 2009 Pilot Chemical NEP Released in November 2011 Chemical NEP Interpretation letters pulled from OSHA s website New interpretation letters and aggressive enforcement to expand PSM coverage More PSM trained compliance officers 5

6 CRITICISM SURROUNDING THE WEST FERTILIZER Numerous New Articles OSHA does not have the resources. OSHA and state plans have 2,000 inspectors for 8 million workplaces or once every 131 years. OSHA s penalties are too low. Congressional hearings Potential legislation Increased enforcement by OSHA 6

7 REFINING NEP ENFORCEMENT STATISTICS Based on the 65 NEP citations: Total Citations 1,542 PSM 1088 (70%) Non-PSM 454 (30%) Total Fines $9,401,

8 REFINING NEP CHARACTERIZATION OF THE CITATIONS Serious % OTS 77 5% Willful/Unclassified 92 Repeat 38 8% Total 1, % 8

9 REFINING NEP ENFORCEMENT STATISTICS Most Citations Fewest Citations 93 (88 PSM) 1 (0 PSM) Highest Penalty $3,042,000 Lowest Penalty $1,125 Average 24 citations $144,638 penalty 9

10 REFINING NEP PSM ENFORCEMENT STATISTICS (65 NEP Citations Issued as of 3/14/11) Mechanical Integrity 202 Process Safety Information 189 Process Hazard Analysis 188 Operating Procedures 184 Management of Change 92 Incident Investigation 71 Compliance Audits 47 Contractors 33 Training % 10

11 REFINING NEP PSM ENFORCEMENT STATISTICS (65 NEP Citations Issued as of 3/14/11) (cont d) Emergency Planning and Response 17 Employee Participation 15 Pre-Startup Safety Review 13 Hot Work Permits 8 Trade Secrets 0 Total PSM Citations

12 REFINING NEP ENFORCEMENT STATISTICS MECHANICAL INTEGRITY J(1) Process equipment 0 J(2) Written procedures 37 J(3) Training 3 J(4) Inspection and testing 0 J(4)(i) Inspection and testing 29 J(4)(ii) Engineering practices 22 J(4)(iii) Frequency J(4)(iv) Documentation 14 J(5) Equipment deficiencies 61 J(6)(i) Quality assurance 0 J(6)(ii) Inspections 9 J(6)(iii) Materials and spare parts 4 TOTAL

13 REFINING NEP ENFORCEMENT STATISTICS J-2 Mechanical Integrity Program No Procedures for: Pressure vessels with integrally bonded liners Corrosion under insulation inspections for pressure vessels and piping Addressing anomalous readings pertaining to metal thickness Determining thickness measurement frequency for pressure vessels Determining the representative number of thickness measurements 13

14 REFINING NEP ENFORCEMENT STATISTICS J-4 Testing and Inspections Failure to follow own scheduled T/I Visual inspections Ultra sound Internal corrosion TML s Vibration analysis Failure to follow RAGAGEP Testing of wrong locations Testing of wrong frequency Insufficient number of tests Failure to document the T/I results 14

15 REFINING NEP ENFORCEMENT STATISTICS 119(J)(5) Equipment Deficiencies TML s below recommended thickness H 2 S, HF & LEL detectors not working Temperature gauge broken Chains for operating valves missing Relieve valve set at 270 PSI when MAWP was 150 PSI 15

16 REFINING NEP ENFORCEMENT STATISTICS PROCESS SAFETY INFORMATION (PSI) D Schedule/Prioritization 2 D(1) Information re: Hazards 0 D(2) Technological Information 17 D(3) Equipment Information 170 Total

17 REFINING NEP ENFORCEMENT STATISTICS PROCESS SAFETY INFORMATION (PSI) D(3)(i) Information on Equipment 5 D(3)(i)(A) Materials of Construction 5 D(3)(i)(B) P&ID s 38 D(3)(i)(C) Electrical Classification 7 D(3)(i)(D) Relief System Design and Design Basis 27 D(3)(i)(E) Ventilation System Design 2 D(3)(i)(F) Design Codes and Standards 9 D(3)(i)(H) Safety Systems 1 D(3)(ii) D(3)(iii) Document Equipment complies with RAGAGEP Equipment Designed on a Code no Longer in General Use Total

18 REFINING NEP ENFORCEMENT STATISTICS P&ID s Inaccurate info on P&ID s Vessel or pump out of service Wrong pressure or temperature Lines mislabeled Omissions from P&ID s Temperature indicator Sight glass By-pass line New equipment New lines 18

19 REFINING NEP ENFORCEMENT STATISTICS 119(d)(3)(i)(D) Relief System Design and Design Basis Blowdowns/Atmospheric Discharge Lack of technical data to show safe release to atmosphere Relief Systems Adequacy following changes especially changes in thru-put Design basis lack of technical support 19

20 REFINING NEP ENFORCEMENT STATISTICS 119(d)(3)(ii) Equipment with RAGAGEP Facility Siting NFPA 496 and API 752 Electrical classifications API 500 Trailers API 753 Relief Valves and Design ASME & API 520 Adequacy and sizing of valves No PSV s Intervening valves 20

21 REFINING NEP ENFORCEMENT STATISTICS PROCESS HAZARD ANALYSIS E(1) Appropriate PHA/Prioritization 12 E(2) Methodologies 0 E(3) PHA addresses 0 E(3)(i) Hazards 15 E(3)(ii) Incidents 10 E(3)(iii) E and A Controls 15 E(3)(iv) Failure of Controls 11 E(3)(v) Facility siting 31 E(3)(vi) Human factors 23 E(3)(vii) Qualitative evaluation 2 E(4) Team of Experts 0 E(5) Findings/recommendations 53 E(6) Revalidation 15 E(7) Revalidation records 1 TOTAL

22 REFINING NEP ENFORCEMENT STATISTICS 119(e) PHA s PHA Failure to consider all scenarios Loss of utilities or control rooms Fires and releases of HHC s Failure to consider near misses Propane leaks Oil Spills Fires Failure to adequately consider Facility Siting Human factors 22

23 REFINING NEP ENFORCEMENT STATISTICS Failure to address findings Ranged 2-15 years Complexity gravity time (citation factors) Failure to document corrective measures 23

24 REFINING NEP ENFORCEMENT STATISTICS OPERATING PROCEDURES F(1) Written procedures 18 F(1)(i) Operating phases 65 F(1)(ii) Operating limits 26 F(1)(iii) Safety and health 12 F(1)(iv) Safety systems 9 F(2) Access 3 F(3) Certification 23 F(4) Safe work practices 28 TOTAL

25 REFINING NEP ENFORCEMENT STATISTICS SOP s Lack operating limits or consequences of deviation Missing essential step in procedure Referring to outdated equipment, step or specific manager Error with locks or carseals on valves for startup 25

26 REFINING NEP ENFORCEMENT STATISTICS Safe Work Practices Procedures/practices for controlling motorized vehicles in process areas OSHA relies electrical classification drawings to show a hazard 26

27 REFINING NEP ENFORCEMENT STATISTICS MANAGEMENT OF CHANGE L(1) Written procedures 40 L(2) Considerations 2 L(2)(i) Technical basis 3 L(2)(ii) Impact of change 9 L(2)(iii) Operating procedures 1 L(2)(iv) Time Period 3 L(2)(v) Authorization requirements 2 L(3) Employee training 4 L(4) Update PSI 22 L(5) Revise operating procedures 6 TOTAL

28 REFINING NEP ENFORCEMENT STATISTICS MOC s Failure to do MOC s (adequacy) Throughput increases Changing startup pressures Rerating boilers Removing column, quench water Failure to do related updates PSI Procedures Training 28

29 Summary of OSHA s Chemical NEP Pilot Program has ended. National Program started in November Applies to chemical plants subject to PSM. Applies nationwide to all OSHA regions and state plans. State plans must implement the chemical NEP within 6 months or develop one that is at least as effective. 29

30 Chemical NEP Programmed and Unprogrammed Inspections Programmed inspections under this NEP shall be randomly selected sites from the Region s revised lists 3-5 programmed inspections per Area Office per year (52 Area Offices) Unprogrammed inspections: other triggers for a Chemical NEP inspection: Accident Catastrophe Complaint Referral Site-specific targeting plan 30

31 Chemical NEP Dynamic Lists CSHO s should verify the implementation of PSM elements to ensure that the employer s actual program is consistent with their written program. Three OSHA inspection protocols called Dynamic Lists : PSM General Ammonia Refrigeration Chemical Processing These lists will be periodically updated and are not available for public review 31

32 Chemical NEP Prior PSM Citations: Abatement Requirement During the course of the inspection, the CSHO shall review abatement for all PSM citations issued within the previous 6 years to determine whether the hazard still exists. If a hazard exists, the CSHO shall determine whether there has been a failure to abate in accordance with CPL FOM, and issue a notice for failure to abate as appropriate. FTA penalties can be up to $7,000 per day per violation. 32

33 Chemical NEP Staffing and Duration of Inspection Usually 1-2 compliance officers Inspectors must take specialized PSM training classes 134 man hours for Chemical NEP inspection (includes preparation, opening, site work and drafting citations and reports) 25 man hours for average OSHA inspection 1000 man hours for Refining NEP inspection 33

34 Current Inspection Data for Chemical NEP CHEM NEP data from May 1, 2009 to Nov. 9, 2012 Total Inspections Unprogrammed Programmed CHEM NEP Violations (Federal only)...2,339 34

35 OSHA New Citation Data Tabulation System New citation data system still being implemented Current Statistical Breakdown for Top Five PSM Violations for Chem NEP. 1. (j) Mechanical Integrity 2. (d) Process Safety Information 3. (f) Operating Procedures 4. (e) Process Hazard Analysis 5. (l) Management of Change Same top five PSM citations as in Refining NEP. 35

36 CHEMICAL NEP ENFORCEMENT STATISTICS (Based on Sample of 98 Citations) Based on the 98 NEP citations sampled: Total Citations 1031 PSM 678 (65%) Non-PSM 353 (35%) Total Fines $4,147,

37 CHEMICAL NEP CHARACTERIZATION OF THE CITATIONS Serious % OTS % Willful/Unclassified 7 Repeat 15 2% Total % 37

38 CHEMICAL NEP ENFORCEMENT STATISTICS Approximately 20 Facilities with No Citations (No PSM Process) Most Citations Fewest Citations 49 (25 PSM) 1 ( 0 PSM) Highest Penalty $441,000 Lowest Penalty $ 0 Average 11 citations $42,300 penalty 38

39 CHEMICAL NEP PSM ENFORCEMENT STATISTICS (98 NEP Citations Sampled) Mechanical Integrity 156 Process Safety Information 140 Operating Procedures 114 Process Hazard Analysis 106 Management of Change 44 Compliance Audits 35 Training 21 Incident Investigation 19 Employee Participation % 39

40 CHEMICAL NEP PSM ENFORCEMENT STATISTICS (98 NEP Citations Sampled) Contractors 14 Emergency Planning and Response 7 Pre-Startup Safety Review 5 Hot Work Permits 1 Trade Secrets 0 Total PSM Citations

41 CHEMICAL NEP ENFORCEMENT STATISTICS MECHANICAL INTEGRITY J(1) Process equipment 0 J(2) Written procedures 41 J(3) Training 5 J(4) Inspection and testing 0 J(4)(i) Inspection and testing 28 J(4)(ii) Engineering practices 11 J(4)(iii) Frequency J(4)(iv) Documentation 10 J(5) Equipment deficiencies 28 J(6)(i) Quality assurance 2 J(6)(ii) Inspections 6 J(6)(iii) Materials and spare parts 4 TOTAL

42 CHEMICAL NEP ENFORCEMENT STATISTICS J-2 Mechanical Integrity Program Summary No procedures for mechanical integrity Procedures Inadequate Inconsistent with RAGAGEP Critical Step Wrong Critical Omissions Written procedures contained no reference to applicable RAGAGEP No procedures in place for piping or valves showing signs of degradation or rust The employer s critical equipment list did not include certain storage tanks and air compressors Procedures did not specify the necessary torque for flange bolts 42

43 CHEMICAL NEP ENFORCEMENT STATISTICS J-4 Testing and Inspections Summary No Inspection Schedule Did Not Follow Own Inspection Schedule Schedule Inconsistent with RAGAGEP Examples Inspections were not done on storage tanks for anhydrous ammonia, liquid chlorine, and sulfur dioxide Inspections were not done on pre-existing TML locations Employer did not conduct inspections per IIAR Bulletin 110 or its equivalent Pressure relief valves had not been inspected every 5 years to comply with ASHRAE-15 Inspection and NDE were not done on process equipment per RAGAGEP such as API 570, API RP 575, and ASME/ANSI B

44 CHEMICAL NEP ENFORCEMENT STATISTICS 119(J)(5) Equipment Deficiencies Visual concerns detected during walkaround Poor condition of paint/external coating was not addressed Rusted, pitted, and corroded piping were in use Valves were missing handles and could not be operated Calculated data TML s below recommended thickness Emergency exhaust and relief discharge piping were undersized 44

45 CHEMICAL NEP ENFORCEMENT STATISTICS PROCESS SAFETY INFORMATION (PSI) D Schedule/Prioritization 4 D(1) Information re: Hazards 0 D(2) Technological Information 21 D(3) Equipment Information 115 Total

46 CHEMICAL NEP ENFORCEMENT STATISTICS PROCESS SAFETY INFORMATION (PSI) D(3)(i) Information on Equipment 7 D(3)(i)(A) Materials of Construction 2 D(3)(i)(B) P&ID s 26 D(3)(i)(C) Electrical Classification 5 D(3)(i)(D) Relief System Design and Design Basis 11 D(3)(i)(E) Ventilation System Design 6 D(3)(i)(F) Design Codes and Standards 7 D(3)(i)(G) Material and Energy Balance 1 D(3)(i)(H) Safety Systems 3 D(3)(ii) D(3)(iii) Document Equipment complies with RAGAGEP Equipment Designed on a Code no Longer in General Use Total

47 CHEMICAL NEP ENFORCEMENT STATISTICS P&ID s Current P&IDs were not available Errors Two valve tags were reversed Pressure indicators were missing in the field Pipe sizes were labeled improperly Valves were in the wrong place Omissions P&ID did not include information required by RAGAGEP, ANSI/ISA S5.1 Code Valves or equipment missing 47

48 CHEMICAL NEP ENFORCEMENT STATISTICS 119(d)(3)(i)(D) Relief System Design and Design Basis No worst case scenario had been developed No information for the relief system was available No documentation for design basis for the relief system for tanks and vessels 48

49 CHEMICAL NEP ENFORCEMENT STATISTICS 119(d)(3)(ii) Equipment with RAGAGEP No documentation of compliance with the HFIPI Guideline for the Bulk Storage of Anhydrous Hydrogen Fluoride No documentation of compliance with IIAR Bulletin 110 where relief valves could relieve to an unsafe location No documentation that relief valves complied with IIAR Bulletin 114 No documentation of compliance with RAGAGEP where a vessel s U-1 had not been maintained Failure to document compliance with API 520 for relief systems Technical Engineering Issues and Non-Compliance Co-location of equipment using combustion air and equipment containing refrigerant did not comply with ANSI/ASHRAE 15 Location of discharge for pressure relief devices did not comply with ANSI/IIAR Relief systems not located properly Pipes and valves not labeled properly 49

50 CHEMICAL NEP ENFORCEMENT STATISTICS PROCESS HAZARD ANALYSIS E(1) Appropriate PHA/Prioritization 10 E(2) Methodologies 1 E(3) PHA addresses 1 E(3)(i) Hazards 17 E(3)(ii) Incidents 4 E(3)(iii) E and A Controls 9 E(3)(iv) Failure of Controls 6 E(3)(v) Facility siting 11 E(3)(vi) Human factors 9 E(3)(vii) Qualitative evaluation 0 E(4) Team of Experts 1 E(5) Findings/recommendations 26 E(6) Revalidation 10 E(7) Revalidation records 1 TOTAL

51 CHEMICAL NEP ENFORCEMENT STATISTICS 119(e) PHA s Failure to conduct an initial PHA on a covered process Failure to consider all scenarios Loss of power Hazards associated with combustible dust Outdoor environmental factors affecting the safe operation of process equipment Failure of pressure relief devices Specific incident that occurred at the plant (either before the PHA was done or after) Failure to adequately consider Facility Siting Human Factors 51

52 CHEMICAL NEP ENFORCEMENT STATISTICS 119(e) PHA s (cont d) Failure to address findings Employer could not verify that recommendations from a 1998 PHA were resolved Failure to establish a system to address recommendations Failure to document the reasons an alternative resolution was adopted rather than that recommended by the PHA team Failure to communicate resolutions of PHA recommendations to affected employees Complexity gravity time (citation factors) Failure to re-do or revalidate a PHA within 5 years 52

53 CHEMICAL NEP ENFORCEMENT STATISTICS OPERATING PROCEDURES F(1) Written procedures 21 F(1)(i) Operating phases 38 F(1)(ii) Operating limits 10 F(1)(iii) Safety and health 14 F(1)(iv) Safety systems 6 F(2) Access 2 F(3) Certification 17 F(4) Safe work practices 6 TOTAL

54 CHEMICAL NEP ENFORCEMENT STATISTICS SOP s Operating procedures were not being implemented by employees Factual errors Listing out of service equipment Omitting steps Regulatory errors Steps were unclear Procedures did not address which employees were authorized to perform the various steps Procedures had not been developed for each phase of operating the process 54

55 CHEMICAL NEP ENFORCEMENT STATISTICS Annual Certification of Operating Procedures Certification was not done Certification was not valid because procedures were not accurate 55

56 CHEMICAL NEP ENFORCEMENT STATISTICS Management of Change (44 Citations) Failure to do MOC Throughput changes Change in PPE for employees opening a vessel Change in TML location MOC was not completed before the equipment change occurred Failure to evaluate Impact of the change on safety and health Failure to do related updates PSI Procedures Training 56

57 LESSONS LEARNED FROM PSM CITATION PATTERNS OSHA s aggressive interpretations of PSM standard OSHA s selective interpretations of RAGAGEP OSHA demands documentation for PHA, audit and incident investigation findings. Citation patterns show OSHA s PSM priorities 57

58 OSHA S AGGRESSIVE INTERPRETATIONS Piping and Instrumentation drawings Applying steam constitutes a change Covering mixtures of less than 10,000 lbs of flammables under the PSM standard. Facility siting: Determining that 1 in 100 million years risk basis for a willful citation. Required to keep PHA documentation from 1994 and

59 OSHA s Use of RAGAGEP Most Frequently Referenced RAGAGEPs API 752 API 570 API 510 Management of Hazards Associated with Location of Process Plant Permanent Buildings Piping Inspection Code: In-Service Inspection, Rating, Repair, and Alteration of Piping Pressure Vessel Inspection Code: In-Service Inspection, Rating, Repair, and Alteration API 521 Pressure-Relieving and Depressuring Systems 59

60 OSHA s Use of RAGAGEP API 574 Inspection Practices for Piping System Components API 520 API 753 Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries Management of Hazards Associated with Location of Process Plant Portable Buildings ANSI/ISA S Functional Safety: Safety Instrumented Systems for the Process Industry Sector ASME/ANSI B31.1 and B31.3 (piping) 60

61 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Electrical Safety Respirators Lockout/Tagout Subpart D - Walking/Working Surfaces Machine Guarding 61

62 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Electrical Working space around equipment was not kept clear Covers for electrical installations were not secured/all unused openings were not effectively closed Improper grounding Flexible cords and cables were used as a substitute for fixed wiring Unclassified electrical equipment was used in a classified area Defective electrical equipment was not removed from service Proper electrical protective equipment was not provided where necessary (FR clothing, face shields, NFPA 70E considerations for arc flash) 62

63 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Respirators Employer failed to determine a reasonable estimate of employee exposure to respiratory hazards Written respiratory protection program was not in place when respirators were necessary Medical evaluations were not provided before employees were fit-tested or required to use respirators Fit-testing was not provided prior to initial use of the respirator Employees did not receive training before being allowed to use tight-fitting respirators Respirators were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition 63

64 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Lockout/Tagout Failure to develop, document, and utilize written lockout procedures for specifically identified equipment Lockout/tagout devices did not meet the requirements of (c)(5) identify employee, tagouts must be nonreusable, etc. Periodic inspections of the lockout/tagout procedures were not completed Lockout/tagout training was deficient where each employee had his own way of locking out Lockout/tagout procedures were not implemented as required employees failed to follow the procedures In group lockout scenarios, each employee failed to affix his own lockout device 64

65 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Subpart D Walking/Working Surfaces Ladderways and platforms were not adequately guarded Wall openings over 4 feet from the level below were not adequately guarded Open-sided floors and platforms over 4 feet from the level below were not adequately guarded 65

66 CHEMICAL NEP MOST FREQUENTLY CITED NON-PSM CITATIONS Machine Guarding Inadequate guarding for: Drill presses Fans Augers Saws Conveyors Grinders Lathes Shafts and shaft ends Milling machines Chains and belts 66

67 Regulatory Update: May 21, 2009 Kaster Letter PSM - Calculating TQ s Question: Is the total mass of a mixture consisting of a fine, non-soluble, non-combustible solid combined with a flammable liquid considered when determining if a threshold quantity (TQ) is present in a process? Rationale: If the mixture as a whole meets the 29 CFR (c)(iii) definition of a flammable liquid, then the total amount of flammable liquid is 10,000 pounds, even if some components(s) of the mixture alone would not meet the required flash point. Answer: Because the mixture in question meets the definition of a liquid and has a flashpoint of less than 100 F, it is a flammable liquid. A process containing 10,000 pounds or more of the mixture would be covered under the PSM standard. 67

68 RECOMMENDATIONS First Recommendation Use of the Citation Data Auditing Preparing for inspections Settlements and potential repeat citations Due diligence 68

69 RECOMMENDATIONS Second Recommendation Review prior citations for PSM violations Go to osha.gov Check OSHA s records on citations for PSM violations Gather documents to show abated Audit to ensure not recurring Third Recommendation Do the Unit selection analysis for the most hazardous process 69

70 RECOMMENDATIONS (cont d) Fourth Recommendation Conduct an Audit of Selected Unit 70

71 RECOMMENDATIONS (cont d) Traditional Safety Focus include in Unit audit Electrical LOTO PPE Guarding Respirators Walking/Working Surfaces Consider whether you want to do audit under privilege. See case where we successfully defended a claim of attorney privilege for a gap analysis under Refining NEP. 71

72 RECOMMENDATIONS (cont d) Fifth recommendation: Train a team to manage the inspection Sixth recommendation: Interview disgruntled employees 72

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR 1910.119 PSM - Definition Not all refining hazards are caused by the same factors or involve ve the same degree of potential damage.

More information

Process Safety Management is the application of management principles and systems to the identification, understanding, and control of process

Process Safety Management is the application of management principles and systems to the identification, understanding, and control of process 29CFR1910.119 Process Safety Management is the application of management principles and systems to the identification, understanding, and control of process hazards to protect employees, facility assets

More information

Introduction to Emergency Response & Contingency Planning

Introduction to Emergency Response & Contingency Planning & Contingency Planning Rationale Why is it important for you to learn this material? Designed for those who may witness a release, this is an introductory course designed to help ensure those who are likely

More information

Elements of a Lockout/Tagout Program OSHA

Elements of a Lockout/Tagout Program OSHA September 15, 2015 Elements of a Lockout/Tagout Program OSHA 1910.147 Dayna Noble Industrial Safety Consultant Specialist Ohio BWC 567-204-8917 Dayna.noble@bwc.state.oh.us Top 10 most frequently cited

More information

SAFETY POLICY AND PROCEDURE MANUAL QUESTIONNAIRE

SAFETY POLICY AND PROCEDURE MANUAL QUESTIONNAIRE The following questionnaire is designed to aid us in the creation of your policy and procedure manual. Please place a checkmark in the boxes that correspond to the sections that you would like to be included

More information

Written Programs Listing

Written Programs Listing Written Programs Listing Bloodborne Pathogens (BBP) (29CFR1910.1030) This standard requires that precautions be taken to prevent the transmission of bloodborne pathogens. Viruses and bacteria can be found

More information

James J Arendas Ph.D.

James J Arendas Ph.D. James J Arendas Ph.D. Safety Program Elements Management Commitment Hazard Identification Hazard Correction Training Hazard Identification Qualified and Competent Persons Identify Hazards in the Workplace

More information

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Verification Of Calibration for Direct-Reading Portable Gas Monitors U. S. Department of Labor Occupational Safety and Health Administration Directorate of Science, Technology and Medicine Office of Science and Technology Assessment Verification Of Calibration for Direct-Reading

More information

AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF. SEMS HAZARD ANALYSIS TRAINING September 29, 2011

AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF. SEMS HAZARD ANALYSIS TRAINING September 29, 2011 AUSTRALIA ARGENTINA CANADA EGYPT NORTH SEA U.S. CENTRAL U.S. GULF SEMS HAZARD ANALYSIS TRAINING September 29, 2011 Purpose The purpose of this meeting is to provide guidelines for determination of hazard

More information

Product Information Report Lockout/Tagout Hazardous Energy Control

Product Information Report Lockout/Tagout Hazardous Energy Control Overview A properly implemented (LOTO) program is designed to protect workers involved in the maintenance and servicing of equipment from the dangerous effects of hazardous energy caused by the unexpected

More information

RiskTopics. Lockout/Tagout October 2017

RiskTopics. Lockout/Tagout October 2017 RiskTopics Lockout/Tagout October 2017 This Risktopic is designed to outline guidelines for lockout/tagout and provide assistance in developing a management program to reduce the risk of injury from unintended

More information

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY 1. CONTROL OF HAZARDOUS ENERGY POLICY AND PROCEDURES A. OSHA References: 29 CFR 1910.147, 29 CFR 1910.332, 29 CFR 1910.333, 29 CFR 1926.417 B.

More information

Hazardous Materials Management Guidelines

Hazardous Materials Management Guidelines Environmental, Health and Safety Guidelines Hazardous Materials Management Guidelines Applicability These guidelines apply to facilities and activities involving the transportation, production, handling,

More information

The Proper Procedure

The Proper Procedure The Proper Procedure Lockout Lockout is used to prevent the release of hazardous energy or equipment from starting by applying a lockout device and lock A padlock is placed on the appropriate energy isolating

More information

Lockout/Tagout Training Overview. Safety Fest 2013

Lockout/Tagout Training Overview. Safety Fest 2013 Lockout/Tagout Training Overview Safety Fest 2013 Purpose of Lockout/Tagout The standard covers the servicing and maintenance of machine and equipment in which the unexpected energization or start up of

More information

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program. Safety & Health Program 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 Compressed Gas Plan Purpose It is the policy of EMA to permit only trained and authorized

More information

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents Owner: HSE Performance Assurance ALL HSE PRC 172 Approved By: Manager, HSE Performance Assurance Retention Code: CG01 CA Revised: March 2015 Review Frequency: Five years or less Table of Contents 1.0 Purpose...

More information

DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM

DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM DUQUESNE UNIVERSITY LOCKOUT/TAGOUT PROGRAM Prepared by: Environmental Health and Safety Department TABLE OF CONTENTS Page Purpose 1 Scope 1 Introduction 2 Regulatory Requirements 2 Protective Materials

More information

Lockout / Tag out Program

Lockout / Tag out Program Lockout / Tag out Program Presented by DOSHTI www.doshti.com You will learn Purpose of Lockout- Tag out Requirements for LOTO Types of Hazardous Energy Procedures for LOTO The OSHA Standard for the Control

More information

Lockout/Energy Control

Lockout/Energy Control Lockout/Energy Control Presented By: Sotaris, LLP 2000 Auburn Drive, Suite 200 Beachwood, Ohio 44122 P: 216-378-7650 F: 866-794-5756 W: www.sotaris.com E: awj@sotaris.com 1 About Me Andrew W. Johnson,

More information

RMP/PSM WEBINAR SERIES

RMP/PSM WEBINAR SERIES RMP/PSM WEBINAR SERIES Webinar Starts at 08:00 PT Please call (877) 532-0806 if you are having technical issues. The background music may be used to adjust your audio volume. IIAR STANDARDS AND HOW THEY

More information

Management Plan for Electrical Safety ISD #535

Management Plan for Electrical Safety ISD #535 Management Plan for Electrical Safety ISD #535 Health & Safety Office Maintenance Service Building 10 SE 9 ½ Street Rochester, MN 55904 507-328-4507 MANAGEMENT PLAN FOR ELECTRICAL SAFETY Table of Contents

More information

Control of Hazardous Energy Lockout / Tagout Program

Control of Hazardous Energy Lockout / Tagout Program Control of Hazardous Energy Lockout / Tagout Program August 2016 Table of Contents Purpose... 1 Scope and Application... 1 Responsibilities... 1 Environmental Health and Safety Personnel (EH&S)... 1 Directors

More information

Leader s Guide ERI Safety Videos

Leader s Guide ERI Safety Videos 1717 SAFE ELECTRICAL WORK PRACTICES & THE 2018 NFPA 70E Leader s Guide ERI Safety Videos SAFE ELECTRICAL WORK PRACTICES & THE 2018 NFPA 70E This easy-to-use Leader s Guide is provided to assist in conducting

More information

PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT)

PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT) PART Q CONTROL OF HAZARDOUS ENERGY (LOCKOUT-TAGOUT) WAC Page 296-307-320 Control of hazardous energy (lockout-tagout). 1 296-307-32001 What does this section cover? 1 296-307-32003 When does this section

More information

Cal/OSHA: Confined Spaces

Cal/OSHA: Confined Spaces Cal/OSHA: Confined Spaces Special Emphasis Program OSHA Interpretations Common Mistakes Resources/Assistance Available 2012 Confined Space Special Emphasis Program: Why? Recent increase in confined space

More information

BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR

BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR CERTIFICATION EXAMINATION November 2018 (Replaces November 2015) This API Individual Certification Examination is designed to identify applicants possessing

More information

Lockout/Tagout - Energy Control Program

Lockout/Tagout - Energy Control Program Lockout/Tagout - Energy Control Program Lockout and Tagging of ELECTRICAL Circuits This portion of the K.R. Miller Contractors, Inc. safety program has been created to maintain a written copy of procedures

More information

LOCK-OUT/TAG-OUT (LO/TO) SAFETY PROGRAM

LOCK-OUT/TAG-OUT (LO/TO) SAFETY PROGRAM LOCK-OUT/TAG-OUT (LO/TO) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR 1910.147 BASIS: Approximately three million workers in the United States face risks from uncontrolled energy when servicing machinery

More information

Walking-Working Surfaces

Walking-Working Surfaces Walking-Working Surfaces 29 CFR 1910, Subpart D Presented by: Chesapeake Region Safety Council Rod Markley, CSP, CHST, CET Subpart D - Walking-Working Surface Topics we will cover: Background of rule Overview

More information

Risk Management Resources

Risk Management Resources Risk Management Resources Machine Guarding Name: Notes: Electrical Systems: Fire Prevention Are circuit breakers accessible to personnel, protected from physical damage, and located away from ignitable

More information

Confined Space Policy

Confined Space Policy Confined Space Policy Introduction Employees of Lawrence University may at times be required to enter into and perform work inside tanks, chests, sewers, vessels and other confined spaces. Due to the potentially

More information

EM Section 12. Control of Hazardous Energy (Lockout/Tagout)

EM Section 12. Control of Hazardous Energy (Lockout/Tagout) EM 385-1-1 Section 12 Control of Hazardous Energy (Lockout/Tagout) Lockout/Tagout References EM 385-1-1 Section 12 29 CFR 1926.600 (a) (3) i Heavy Equipment 29 CFR 1926.702 (j) (1) Concrete Tools 29 CFR

More information

Start-up, Shutdown and Malfunction Plans. Norman L. Morrow Fresh Air Consulting

Start-up, Shutdown and Malfunction Plans. Norman L. Morrow Fresh Air Consulting Start-up, Shutdown and Malfunction Plans Norman L. Morrow Disclaimer This presentation provides a summary of some SS&M provisions and is not a complete description. Refer to the current Code of Federal

More information

Page: 7/15/2009. Energy control procedures Use of lockout/tagout equipment to ensure safe work practices.

Page: 7/15/2009. Energy control procedures Use of lockout/tagout equipment to ensure safe work practices. 1 of 6 1.0 PURPOSE This program applies to the installation, service, maintenance, or removal of any type of machinery, equipment, or components, in which the unexpected start up or release of stored energy

More information

What Every Town Manager Needs to Know About Workplace Safety

What Every Town Manager Needs to Know About Workplace Safety What Every Town Manager Needs to Know About Workplace Safety Presented to: Massachusetts Municipal Association Annual Meeting & Trade Show January 23, 2016 Mary Dozois, CIH Department of Labor Standards

More information

Lockout / Tagout Safety Program

Lockout / Tagout Safety Program Lockout / Tagout Safety Program Prepared by: The Ohio State University Environmental Health and Safety Occupational Safety & Industrial Hygiene 1314 Kinnear Road Columbus, OH 43212-1168 614-292-1284 Phone

More information

Accident Investigation and Hazard Analysis

Accident Investigation and Hazard Analysis Accident Investigation and Hazard Analysis June 18, 2015 Objectives: Accident Investigation Define accidents Review why accident investigations are important Review the purpose of accident investigations

More information

OSHA must prove. Confined Space Entry. Do you have an effective safety and health program? Some period of time later

OSHA must prove. Confined Space Entry. Do you have an effective safety and health program? Some period of time later Confined Space Entry OSHA background Definitions Program Contractors Permit Rescue Training Stories OSHA must prove Exposed employee Serious hazard Employer knowledge Feasible method to abate hazard More

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Page 1 of 9 ISSUED: 5/00 REVISED: 08/06 Introduction Purpose: In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to Ethylene Oxide. Applicability

More information

Lockout Tagout Program

Lockout Tagout Program Lockout Tagout Program 1.0 INTRODUCTION Public Safety Department Environmental, Health and Safety (EHS) Division Standard Operating Procedure (SOP) #18 Purpose To ensure that machinery or equipment is

More information

CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM

CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM 1.0 REGULATORY AUTHORITY Code of Federal Regulations, 29 CFR 1910.147; California Code of Regulations, Title 8, Sections 2320.1 and 3314; CSU, Fullerton

More information

Hazardous Energy Control (Lockout-Tagout)

Hazardous Energy Control (Lockout-Tagout) Hazardous Energy Control (Lockout-Tagout) The purpose of this program is to prevent inadvertent operation or energization of machines, equipment, or processes in order to protect employees and establish

More information

OSHA Federal Standards October 1, 2014 September 30, 2015

OSHA Federal Standards October 1, 2014 September 30, 2015 OSHA Federal Standards October 1, 2014 September 30, 2015 29 CFR 29 CFR 1910 1910. SUBPARTS MOST FREQUENTLY CITED SERIOUS VIOLATIONS IN GENERAL INDUSTRY 2015 K N D S J O I Z O Z HAZARD COMMUNICATION WRITTEN

More information

Safe Work Practices and Permit-to-Work System

Safe Work Practices and Permit-to-Work System CHAPTER 24 Safe Work Practices and Permit-to-Work System 24.1 INTRODUCTION OSHA s Process Safety Management (PSM) Standard (OSHA, 1992) requires employers to develop and implement safe work practices (SWPs)

More information

Codex Seven HACCP Principles. (Hazard Identification, Risk Assessment & Management)

Codex Seven HACCP Principles. (Hazard Identification, Risk Assessment & Management) Codex Seven HACCP Principles (Hazard Identification, Risk Assessment & Management) Logic sequence for application of HACCP Assemble the HACCP team Describe product Identify intended use Construct a flow

More information

ARKANSAS TECH UNIVERSITY FACILITIES MANAGEMENT HEALTH AND SAFETY MANUAL (LOCKOUT/TAGOUT) 30.0

ARKANSAS TECH UNIVERSITY FACILITIES MANAGEMENT HEALTH AND SAFETY MANUAL (LOCKOUT/TAGOUT) 30.0 () 30.0 The purpose of the Energy Control Policy (Lockout/Tagout) is to ensure that before any employee performs any servicing and/or maintenance on machinery or equipment, where the unexpected energizing,

More information

LO/TO LOCKOUT/TAGOUT PROGRAM

LO/TO LOCKOUT/TAGOUT PROGRAM LO/TO LOCKOUT/TAGOUT PROGRAM April 2017 CONTENTS Section 1: Introduction...1 Section 2: Purpose... 1 Section 3: Application... 1 Section 4: Definitions... 2 Section 5: Roles and Responsibilities... 4 Section

More information

Welding With Arc Welding Equipment

Welding With Arc Welding Equipment Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Welding With Arc Welding Equipment Self Inspection Checklist Guidelines: This checklist

More information

Process Safety Value and Learnings Central Valley Chemical Safety Day March 20, 2014

Process Safety Value and Learnings Central Valley Chemical Safety Day March 20, 2014 Process Safety Value and Learnings Central Valley Chemical Safety Day March 20, 2014 Randy Bennett Sr. Staff Health & Safety Engineer Process Safety Management Group Aera Energy LLC Key Points Process

More information

230-LOCKOUT/TAGOUT PROGRAM

230-LOCKOUT/TAGOUT PROGRAM 230.1 PURPOSE A. To confirm implementation, operation, and recordkeeping of Central New Mexico Community College(CNM) lockout/tagout program in compliance with 29 CFR 1910.147. 230.2 SCOPE A. The requirements

More information

BODY OF KNOWLEDGE TANK ENTRY SUPERVISOR CERTIFICATION PROGRAM Revision 2, October 2013

BODY OF KNOWLEDGE TANK ENTRY SUPERVISOR CERTIFICATION PROGRAM Revision 2, October 2013 BODY OF KNOWLEDGE TANK ENTRY SUPERVISOR CERTIFICATION PROGRAM Revision 2, October 2013 This API Individual Certification Examination is designed to identify applicants possessing the required knowledge

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Purpose In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to glutaraldehyde. Applicability This policy is applicable to all Temple University

More information

MARIPOSA COUNTY LOCKOUT/TAGOUT PROGRAM

MARIPOSA COUNTY LOCKOUT/TAGOUT PROGRAM MARIPOSA COUNTY LOCKOUT/TAGOUT PROGRAM INTRODUCTION Mariposa County ( County ) facilities have equipment and systems that must be deenergized to allow for safe cleaning, repairing, servicing, setting-up,

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Lockout/Tagout Program

Lockout/Tagout Program Lockout/Tagout Program Control of Hazardous Energy Subpart J - 29 CFR 1910.147 29 CFR 1926.417 OSHA Standard All industries must comply Estimated to prevent Approximately 120 fatalities per year 28,000

More information

Respiratory Protection Self Inspection Checklist

Respiratory Protection Self Inspection Checklist Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Respiratory Protection Self Inspection Checklist Guidelines: This checklist covers some

More information

Hazardous Energy Control Lockout/Tagout

Hazardous Energy Control Lockout/Tagout Hazardous Energy Control Lockout/Tagout Debbie Rauen INSafe Safety Consultant Outline Energy Sources Employer Responsibilities Authorized Employee Responsibilities Energy Control (LO/TO) Equipment & Devices

More information

OPERATING PROCEDURES

OPERATING PROCEDURES OPERATING PROCEDURES 1.0 Purpose This element identifies Petsec s Operating Procedures for its Safety and Environmental Management System (SEMS) Program; it applies to all Petsec operations. Petsec is

More information

Before You Fix the Relief Valve Problem

Before You Fix the Relief Valve Problem Before You Fix the Relief Valve Problem Careful considerations when mitigating inadequate relief systems designs Jason Spearow, P.E Presenter Biography Jason Spearow, P.E. Smith & Burgess LLC Senior Process

More information

Energy Control Procedures Lockout/Tagout 29 CFR

Energy Control Procedures Lockout/Tagout 29 CFR Energy Control Procedures Lockout/Tagout 29 CFR 1910.147 Paul Schlumper, PE, CSP Georgia Tech Research Institute What is covered? Servicing and maintenance Normal production operations where: Employees

More information

Lock Out/Tag Out Control of Hazardous Energy

Lock Out/Tag Out Control of Hazardous Energy Lock Out/Tag Out Control of Hazardous Energy University Facilities Internal Procedure: July 1, 2013 Effective date: July 1, 2013 Last Modified: April 2013 Approved by: Bob Wells 1.0 Program Objective UF

More information

Health and Fire Safety Review 2/15

Health and Fire Safety Review 2/15 Health and Fire Safety Review 2/15 1 TABLE OF CONTENTS Page 3 Scope 3 Control of Hazardous Energy (Introduction) 3 Authorized Employee 3 Employer Responsibility 4 Tagout Devices 4 Lockout Devices 5 General

More information

Occupational Safety and Health Administration

Occupational Safety and Health Administration Occupational Safety and Health Administration Standard Number: 1910.134; 1910.1053; 1910.1200; 1926.1153; 1926.1153(c); 1926.1153(c)(1); 1926.1153(d); 1926.1153(d)(1); 1926.1153(d)(2); 1926.1153(d)(2)(iii)(B);

More information

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard CITY AND COUNTY OF DENVER CR&CF RISK UNIT 65.5.11 Compressed Gas Safety Standard 1.0 Introduction 2.0 Scope This standard has been developed to protect all City and County of Denver employees and contractors

More information

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA 1910.269: Electric Power Generation, Transmission, and Distribution Region IV - OSHA Scope This standard covers the operation and maintenance of electric power generation, control, transformation transmission,

More information

Confined Space in Construction

Confined Space in Construction Confined Space in Construction 1926.1201 1926.1213 Confined space means a space that: 1. Is large enough and so configured that an employee can bodily enter it; 2. Has limited or restricted means for entry

More information

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07 16.2.1 INTRODUCTION 16.2.1.1 The purpose of this standard is to establish safety requirements, which include a permit system, for entry into confined spaces. 16.2.2 DEFINITIONS 16.6.2.1 Confined space

More information

Temporary Equipment Checklist

Temporary Equipment Checklist Location: Company Name (owner of equipment): Date: ID No.: Type of Equipment: Permit / WCC number: Equipment supporting: Operations Wells Projects General Yes No N/A Will the equipment operator require

More information

LOCKOUT/TAGOUT PROGRAM

LOCKOUT/TAGOUT PROGRAM LOCKOUT/TAGOUT PROGRAM HOW CLIMATE ENGINEERS INC. COMPLIES WITH THELO/TO STANDARD It is the intent of Climate Engineers Inc. to comply with OSHA s Control of Hazardous Energy Standard (1910.147). The following

More information

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

Lockout - Tagout. Control of Hazardous Energy OSHA Standard Lockout/Tagout Lockout - Tagout Control of Hazardous Energy OSHA Standard 1910.147 What Is Lockout/Tagout? Referred to as LOTO Blocks the flow of energy from power source to the equipment Provides means

More information

WHAT IS GAS TANK/CYLINDER?

WHAT IS GAS TANK/CYLINDER? Introduction To use compressed gas cylinders safely, it is important that they are stored properly, handled correctly, used with the correct equipment, and that the properties of the gases they contain

More information

RUPTURE HAZARD OF PRESSURE VESSELS

RUPTURE HAZARD OF PRESSURE VESSELS United States Office of Solid Waste EPA 550-F-97-002a Environmental Protection and Emergency Response Agency (5104) RUPTURE HAZARD OF PRESSURE VESSELS The Environmental Protection Agency (EPA) is issuing

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

Code(s) DOT 49 CFR 173.3:

Code(s) DOT 49 CFR 173.3: Code(s) DOT 49 CFR 173.3: (c) Packages of hazardous materials that are damaged or found leaking and hazardous materials that have been spilled or leaked may be placed in a metal removable head salvage

More information

THE TLC COMPANIES. Self Inspection Program. Self Inspection. Program. Revised 12/13/2002 DC00026

THE TLC COMPANIES. Self Inspection Program. Self Inspection. Program. Revised 12/13/2002 DC00026 THE TLC COMPANIES Self Inspection Program Self Inspection Program Table of Contents SECTION 1 INSPECTION REQUIREMENTS 1 Informal Inspection 1 General Inspection 1 SECTION 3 CONDUCTING INSPECTIONS 5 Preparation

More information

PRESSURIZED EQUIPMENT AND SYSTEMS

PRESSURIZED EQUIPMENT AND SYSTEMS SECTION 20 PRESSURIZED EQUIPMENT AND SYSTEMS 20.A GENERAL 20.A.01 Inspections and tests - general. a. Pressurized equipment and systems shall be inspected and performance tested before being placed in

More information

Fall Hazards: One of OSHA s Big Three. By Mark A. Lies II and Elizabeth Leifel Ash I. INTRODUCTION

Fall Hazards: One of OSHA s Big Three. By Mark A. Lies II and Elizabeth Leifel Ash I. INTRODUCTION OPTIMUM Articles Provided by www.optimumresultsusa.com Fall Hazards: One of OSHA s Big Three By Mark A. Lies II and Elizabeth Leifel Ash I. INTRODUCTION In 2010, the Bureau of Labor Statistics (BLS) reported

More information

CalARP Checklist Summary of Violations Program Level 3 Facilities

CalARP Checklist Summary of Violations Program Level 3 Facilities County of Sacramento Environmental Management Department Environmental Compliance Division 10590 Armstrong Ave. Suite A Mather, CA 95655 Voice (8am 5pm): 916/875-8400 FAX: 916/875-8513 http://www.emd.saccounty.net

More information

Effective Workplace Inspections

Effective Workplace Inspections Effective Workplace Inspections Why are workplace inspections important? 3600-Safety Inspections-General Information Workplace inspections help prevent injuries and illnesses. Through critical examination

More information

Limited quantities of compressed gases.

Limited quantities of compressed gases. 173.306 Limited quantities of compressed gases. (a) Limited quantities of compressed gases for which exceptions are permitted as noted by reference to this section in 172.101 of this subchapter are excepted

More information

SPECIALIZED ONLINE TRAINING COURSE LIST

SPECIALIZED ONLINE TRAINING COURSE LIST SPECIALIZED ONLINE TRAINING COURSE LIST Grainger Online Safety Manager provides you with access to online training courses covering today's most relevant safety topics. The training content is designed

More information

National Safety Council 94 th Annual Congress and Expo. Commitment to a Proactive Safety Culture: Abnormal Situation Recognition and Management

National Safety Council 94 th Annual Congress and Expo. Commitment to a Proactive Safety Culture: Abnormal Situation Recognition and Management National Safety Council 94 th Annual Congress and Expo Commitment to a Proactive Safety Culture: Abnormal Situation Recognition and Management November 7, 2006 What is the CSB? Independent Federal Agency

More information

Managing Injury Risk at Grain Handling Facilities. Matt Shurtliff Director of Safety and Environmental Issues J.D. Heiskell & Co January 17, 2018

Managing Injury Risk at Grain Handling Facilities. Matt Shurtliff Director of Safety and Environmental Issues J.D. Heiskell & Co January 17, 2018 Managing Injury Risk at Grain Handling Facilities Matt Shurtliff Director of Safety and Environmental Issues J.D. Heiskell & Co January 17, 2018 1 Before We Start If you re unsure of a safe way to do a

More information

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard) Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard) APPLICABILITY: This EH&S Instruction applies to UTAS sites worldwide, including contractors working at UTAS facilities. The document

More information

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Tool Box Talk. Confined Space Entry New Construction Standard (2015) Confined Space Entry New Construction Standard (2015) What s all this about Confined Space Entry and how does it affect the construction industry? On May 4, 2015 the Occupation Safety and Health Administration

More information

Required Courses. Total Hours 39

Required Courses. Total Hours 39 Public Sector Safety & Health Fundamentals Certificate Program for Construction Participants must complete a minimum of seven courses, comprised of required and elective courses, that include a minimum

More information

Respiratory Protection Self-Inspection Checklist

Respiratory Protection Self-Inspection Checklist Respiratory Protection Self-Inspection Checklist Guidelines: This checklist applies to the use of either atmosphere-supplying or air-purifying respirators being worn, voluntarily or otherwise, for comfort

More information

Lockout/Tagout Safety Policy

Lockout/Tagout Safety Policy University of North Carolina Wilmington Environmental Health & Safety Workplace Safety Lockout/Tagout Safety Policy GENERAL The UNCW Environmental Health & Safety Department (EH&S) is authorized by UNCW

More information

Student Shop Safety. University of Tennessee Safety Guide GS-005. Purpose. Scope and Applicability. Definitions and Abbreviations.

Student Shop Safety. University of Tennessee Safety Guide GS-005. Purpose. Scope and Applicability. Definitions and Abbreviations. Student Shop Safety University of Tennessee Safety Guide GS-005 Document Contact: EHS Date effective: August 1, 2012 Revision Date: June 7, 2017 Purpose Machine shops are present in many departments and

More information

Permit-Required Confined Space Entry Program

Permit-Required Confined Space Entry Program Safety & Health Program Permit-Required Confined Space Entry Program General Company Policy 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 The purpose of this program

More information

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS Steve Sherwen Senior Consultant, ABB Engineering Services, Daresbury Park,

More information

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures Number K-3.0 Issued: 1/2009 Revised: 3/2016 Page 1 of 3 1.0 PURPOSE: To standardize procedures associated with production and maintenance welding and to minimize the potential risk of accident or injury

More information

Gettysburg College. Energy Control Program

Gettysburg College. Energy Control Program Gettysburg College Energy Control Program Adopted October 2009 Reviewed and Updated February 2015 Reviewed and Updated July 2015 I. Energy Control Procedures Table of Contents A. General Lockout Procedures

More information

OSHA Federal Standards October 1, 2016 September 30, 2017

OSHA Federal Standards October 1, 2016 September 30, 2017 OSHA Federal Standards October 1, 2016 September 30, 2017 29 CFR 1926 SUBPARTS 29 CFR 1926. C M L L E M M E X M MOST FREQUENTLY CITED SERIOUS VIOLATIONS IN CONSTRUCTION 2017.501(b)(13) FALL PROTECTION

More information

Are Your Credits Worthy?

Are Your Credits Worthy? Are Your Credits Worthy? James R. Lay, P.E. Lisa A. Long Michael L. Marshall, P.E. Jeffrey J. Wanko, P.E., C.S.P. U.S. DOL OSHA 200 Constitution Ave, NW Washington, DC 20210 Lay.Jim@dol.gov Long.Lisa@dol.gov

More information

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC 2017 NWHA TECHNICAL SEMINAR Arc Flash Hazard Awareness WHAT IS ARC FLASH Arc Flash is a short circuit that flashes from one exposed live part to another, or to ground The result is ionized air that creates

More information

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE Date: 04-22-2009 Revision: 02 Page: 1 of 6 SUMMARY: SCOPE: REFERENCE REGULATIONS: Employees using laboratory fume hoods shall observe all applicable

More information

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com Electrical Safety For Managers Updated For 2018 70E Daryn Lewellyn daryn@electricaltrainingpro.com ElectricalTrainingPro.com 877.393.9901 1 Fatalities From Exposure To Electricity 1992-334 Bureau of Labor

More information

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP:

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP: PRESSURE RETEST 49 CFR, 180.407(g) Co#: Vin#: Spec: MAWP: Retest Date: Location: *External Inspection Performed: *Internal Inspection Performed: Test Pressure: psig Held for: min. (Must be at least 10

More information