STANDARD OPERATING PROCEDURE
|
|
- Colin Blair
- 6 years ago
- Views:
Transcription
1 Ref.. Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 3 6. Precautions References Appendices Revision History 14 Original Authorised Copy for: Reading Copy Written by: Reviewed by: Approved by: Signature/Date: Signature/Date: Signature/Date: Page 1 of 16
2 Ref.. 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students making use of the Precisa 1600C Precision Balance in the laboratories of the Pharmacy Department, University of Malta. 2. Objective To describe the procedure for the installation, configuration, operation, calibration, maintenance and troubleshooting of the Precisa 1600C Precision Balance. 3. Definitions 3.1. Adjustable Feet / Levelling Screws: Two circular screws situated at the bottom of the balance that are manipulated to level the balance out Calibration: A procedure performed to check a measuring instrument against an accurate standard to determine any deviations and correct for errors Configuration Parameters: A number of different options that are used to set the balance according to the user s preferences Floating Display: A function that enables the balance to adapt its integration time to the conditions of the environment Main Menu: Allows the user to adapt the balance to his/her changing requirements and to any peripheral conditions. It consists of 4 main options: Calibration to carry out the calibration process Program Second Unit of Mode Key to choose the unit to be set as Unit2 Floating Display to choose the desired time for the floating display, if being used, i.e seconds, 0.16 seconds or 0.32 seconds Stability Detector to choose the desired stability for the balance i.e. Low, Medium or High 3.7. Mode Key: Allows the user to call up functions which are activated once this key is released, such as result, time and date printouts as well as functions that affect the weighing mode such as switching from Page 2 of 16
3 Ref.. Unit1 to Unit2 or vice versa or else to change between percentage and counting mode On/Off Key: To switch the balance on or off T-Key: Used to tare the balance when this is in weighing mode. May also be used to enter configuration menu or main menu, to change from one parameter to the next in the individual sub-menus, to exit a menu and also to call up the calibration programme Tare: Allows the balance to display the weight of the sample only and not the combined weight of the sample and its container Unit1: The basic unit in which values are to be displayed in. This can be set as the gramme [g], grain [GN], penny weight [dwt], troy ounce [ozt], ounce [oz], pound [lb], carat [ct], metric carat [C.M.], Hong Kong tael [tlh], Malaysian tael [tlm] or Taiwan tael [tlt] Unit2: The secondary unit that can be programmed in the main menu. This can bet set as one of the units chosen for Unit1 with the addition of the count [PCS] or percent [%] Weighing pan: The area on top of which the material to be weighed is placed. 4. Responsibility 4.1. The members of the Department of Pharmacy (staff and students) are responsible for following this SOP The designated Laboratory Officer or Laboratory Assistant is responsible for ensuring that this SOP is followed. 5. Procedure 5.1. Installation Place the balance on a stable surface, away from any vibrations Turn the adjustable feet/levelling screws at the bottom of the balance clockwise or anticlockwise until the air bubble in the spirit level is in the centre of the marked circle. Page 3 of 16
4 Ref Insert power supply connector in the plug on the rear of the balance and plug the power supply into the mains supply Press the On/Off Key to activate the balance Wait until a stable 0,00 is displayed before use Configuration Press and hold the T key whilst balance is still switched off Press the On/Off key while still pressing the T key Keep the T key pressed until the desired configuration parameter is displayed (see SOP/PD/304_01/A1) Release the T key to access the desired configuration parameter Press the T key briefly but continuously until the desired function in the configuration parameter is displayed Press and hold the T key again to return to main menu. If this is not pressed for some time, the configuration menu will be abandoned automatically, and the standard configuration stored Using the Main Menu Press and hold the T key until the desired option is displayed Release the T key to enter the desired sub-menu Press the T key briefly but continuously until the desired parameter in the sub-menu is displayed Press and hold the T key to return to the main menu. If this is not pressed for some time, the main menu is automatically abandoned and the balance enters weighing mode once again Weighing Mode Ensure that the desired weighing unit is displayed. If this is not so, press the MODE key until it is displayed if it had been previously set as the basic unit i.e. Unit1 or as the secondary unit i.e. Unit Place sample onto the weighing pan and read off value If using the tare function, place empty weighing container on the weighing pan, press the T key and then place the sample in the weighing container and read of the tared value from the display. Page 4 of 16
5 Ref Use the tare function repeatedly if necessary Using the Mode Key Counting Mode Ensure that PCS was previously set as Unit2 from the main menu Place the number of pieces that are required as reference weight on the weighing pan Press and hold the MODE key until [Unit2 PCS] is displayed Release the MODE key to select the reference weight as the selected number of pieces and also to switch automatically to Unit2 i.e counting mode Remove the number of pieces used to set the reference weight Place the weight that needs to be counted and read the number of pieces from the display Percentage Mode 5.6. Calibration Ensure that % was previously set as Unit2 from the main menu Place the reference weight on the weighing pan Press and hold the MODE key until [ref 100%] is displayed Release the MODE key to set the reference weight as the selected percentage and also to switch automatically to Unit2 i.e percentage mode Remove the reference weight used to programme the percentage function Place the desired sample and read the percentage of the reference weight from the display Allow a warm up time of about 10 minutes after switching the balance on Press and hold the T key until [CAL] is displayed Page 5 of 16
6 Ref Ensure that there is nothing present on the weighing pan. If pan is not empty, and/or the balance is active, the digital display [--0000g] will continue to flash Allow [0000g] to be displayed to indicate that zero point measurement has been carried out Wait until balance display flashes [--1000g] and then place the recommended calibration weight (1000g) on the centre of the pan Wait until display shows [1000g] to indicate that calibration is finished and balance returns to weighing mode 5.7. Maintenance Disconnect balance from its power supply before attempting to clean and leave it in its normal operating position Use a clean fine brush to remove any surrounding powder Use a moistened cloth with a mild cleaning agent to clean and remove any spilt material Ensure that the air bubble in the spirit level on the front end of the scale is in the centre of the marked circle Troubleshooting Fault Possible Cause - Balance not switched on correctly Display does not light up - Balance not connected to mains - Power failure - Faulty microfuse OL is displayed - Weighing limit has been exceeded UL is displayed - Weighing pan and/or pan support has not been assembled - Draught/ air currents present Weighing display changes continuously - Vibrations on table/floor - Weighing pan touching foreign body - Balance not tared Result seemingly incorrect - Balance not levelled - Outdated calibration - Strong temperature fluctuations - Location of balance is undesirable Display flashes continuously during - Calibration weight is too imprecise or calibration does not correspond to the recommended one Page 6 of 16
7 Ref Flow Charts Installation Start Place on stable surface, away from any vibrations Turn adjustable feet until air bubble in spirit level is in the centre of the marked circle Insert power supply connector in the plug on rear of balance and plug power supply into mains supply Press On/Off Key to activate balance Wait until a stable 0,00 is displayed before use End Page 7 of 16
8 Ref Configuration Start Press and hold T key whilst balance is still switched off Press On/Off key while still pressing the T key Desired configuration parameter displayed Keep T key pressed until desired menu is reached Release T key to access desired configuration parameter Press T key briefly but continuously until desired function is displayed Save changes made Do not press any keys and allow balance to automatically return to weighing mode Press and hold the T key to save and return to main menu End Page 8 of 16
9 Ref Using the Main Menu Start Press and hold T key Desired option displayed Keep T key pressed until desired parameter is reached Release T key to enter its submenu Press T key briefly but continuously until desired parameter is reached Save changes made Do not press any keys and allow balance to automatically return to weighing mode Parameter saved and returns to main menu End Page 9 of 16
10 Ref Weighing Mode Start Desired weighing unit display Desired weighing unit previously set as Unit1 orunit2 Press On/Off key to switch off balance 1 Using tare function Place sample and container onto weighing pan Press and hold MODE key Press and hold T key and simultaneously press the On/Off key again Place empty weighing container on balance Read off value from the display Release MODE key when [Unit1 x*] or [Unit2 x*] is being displayed 1 Release T key when [Unit1] is displayed Briefly but continuously press T key until [Unit1 x*] is displayed Press T key Place sample in weighing container Keep using tare function repeatedly if necessary Press and hold T key to save and return to main menu Allow balance to enter weighing mode Press and hold MODE key until [Unit1 x*] is displayed End 1 * x represents desired weighing unit Page 10 of 16
11 Ref Using the Mode Key Start Change balance to counting mode Change balance to percentage mode 1 PCS previously set as Unit2 from main menu Press and hold T key until [Unit2] is displayed % previously set as Unit2 from main menu Press and hold T key until [Unit2] is displayed Place number of pieces required as reference on pan Press T key briefly and continuously until [Unit2 PCS] is displayed Place reference weight on weighing pan Press T key briefly and continuously until [Unit2 %] is displayed Press and hold MODE key until [Unit2 PCS] is displayed Press and hold T key to save and return to main menu Press and hold MODE key until [ref 100%] is displayed Press and hold T key to save and return to main menu Release MODE key to select the reference weight and to switch automatically to Unit2 Release MODE key to set reference weight as the selected percentage and to switch automatically to Unit2 Remove number of pieces used to set reference weight and place the weight that needs to be counted Remove reference weight and place desired sample Read the number of pieces from the display Read the percentage of the reference weight from the display 1 End Page 11 of 16
12 Ref Calibration Start Allow a warm up time of about 10 minutes after balance is switched on Press and hold T key until [CAL] is displayed Digital display [--0000g] continues to flash Remove anything that may be present on weighing pan Allow [0000g] to be displayed Wait until display flashes [--1000g] Place standard 1000g on centre of weighing pan Wait until display shows a stable [1000g] Balance returns to weighing mode End Page 12 of 16
13 Ref Maintenance Start Balance needs cleaning Disconnect balance from power supply Any surrounding powder Remove using a fine brush Any spilt material Remove using a moistened cloth with a mild cleaning agent Air bubble in spirit level is in centre of marked circle Manipulate adjustable feet until this is accomplished End Page 13 of 16
14 Ref.. 6. Precautions 6.1. Do not install near extremes of heat and cold Protect balance from dust and air draughts Keep weighing pan clean and dry to prevent inaccuracies Do not move balance during weighing Ensure that the maximum tolerate weight of 180g is not exceeded during weighing procedures and also when using the tare function Do not leave any items on the balance when this is not in use Only use balance if the spirit level is correct Adjust the air bubble in the spirit level each time the balance is to be moved to another location If an error message is displayed when balance is switched on, switch balance off and on again. If error message re-appears, contact supplier for further information Avoid static charge buildup of the material to be weighed and of the weighing container When transferring balance to a significantly warmer environment, allow it to acclimatise for approximately 2 hours at room temperature after it has been disconnected from the mains. 7. References N/A 8. Appendices /A1 Configuration Parameters Table 9. Revision History Version Number Amendments/ Reasons for change 01 Initial Release Page 14 of 16
15 Ref.. /A1 Configuration Parameters Table Configuration Parameter Display Symbol Function Basic unit of balance Unit1 To choose the weighing unit to be set as Unit1 Calibration CAL To choose whether to carry out calibration [CAL YES] or to disable this function [CAL NO] Baudrate bdr To choose the desired baudrate from [300 bdr], [600 bdr], [1200 bdr], [2400 bdr], [4800 bdr] or [9600 bdr] Parity PAr To choose between having no parity [PAr no], an odd parity [PAr odd] or an even parity [PAr E] Printing Print To choose between no printing [Print no], single printout of each value [Print UST], single printout of each stable value [Print ST],auto printout after changing load [Print Lch] or continuous printout [Print PEr] Combined print function Prt-ALL To combine a printout with weighing result, date and time etc [Prt-ALL YES] or else to disable this function [Prt-ALL no] Delay Printout Prt-dEL To delay printout by 0.5, 1 or 2 seconds or else to disable this delay function [Prt-dEL no] Last Digit LASt d To choose whether the last digit is to be always visible [LASt d on] or only visible when stable [LASt d off] Automatic zero adjustment A-ZEro To choose whether this is to be switched on [A-ZEro on] or off [A-ZEro off] Menu Inhibit LAtch To choose whether to inhibit changes from being made to the configurations parameters menu [LAtch on] or else to disable this option [LAtch off] Page 15 of 16
16 Ref.. Status Printout StAtUS Prt To perform a printout of all the information available about the balance including the parameters that are set in the main and configuration menus Page 16 of 16
American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000
American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-50 BLADE-400 BLADE-550 BLADE-1000 User Manual Blade Series Manual Thank you for purchasing the American Weigh BLADE-Series
More informationCÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)
American Weigh Scales CÜBE User Manual CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g) Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 CUBE Manual Thank you for purchasing the American
More informationOperation Instruction. BSM Series Electronic Precision Balances
Operation Instruction BSM Series Electronic Precision Balances Contents Application 1 Safety Precautions 2 Getting Started 3 Function Instruction 7 Operation 8 Basic Weighing Function 8 Calibration and
More informationBCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)
American Weigh Scales BCM-Series User Manual BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.2 BCM-Series Manual Thank you for purchasing
More informationAXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)
American Weigh Scales AXIS User Manual AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 AXIS Manual Thank you for purchasing the
More informationKERN CM Version /2004
GB KERN CM Version 1.6 01/2004 Operation Instrustions Pocket Balance / Carat balance Tabel of contents: 1 Technical data 18 2 Declaration of conformty 19 3 Fundamental information (general) 20 3.1 Intended
More informationOperating Manual Body fat balance
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Manual Body fat balance KERN MFB Version
More informationUser Manual. Portable Balances PL-E
User Manual Portable Balances PL-E u www.mt.com/pl-e-oi u www.mt.com/library Portable Balances 3 Overview components 4 3 2 1 5 6 7 8 7 11 10 9 Components overview legend 1 Operation keys 2 Display 3 Adapter
More informationAmerican Weigh Scales, Inc. LB User Manual
g American Weigh Scales, Inc. LB-1000 C o m p a c t B o w l S c a l e LB-1000 User Manual LB-1000 Manual Thank you for purchasing the American Weigh LB-1000 digital scale. Please read all operating instructions
More informationIntroduction. Check for the following items before use.
Introduction Thank you for purchasing Density Measurement Kit for HT/HTR balance. This manual is intended to describe only density measurements for HT/HTR balance. Please use this manual together with
More informationSartorius Basic plus Service Manual. WBP5007-e95021
Sartorius Basic plus Service Manual WBP5007-e95021 Contents Page Exploded-View Diagram 1 4 Exploded-View Diagram 2 6 Exploded-View Diagram 3 8 Auxiliary Service Tools and Equipment 10 General Handling
More informationEclipse Precision & Analytical Balances
4 Eclipse Precision & Analytical Balances Designed for advanced scientists and researchers, the Eclipse occupies minimal space on the laboratory work bench, yet maintains optimal performance. Its elegant
More informationFULL OPERATING INSTRUCTIONS FOR MODELS AE 50/100 and/or AE 160/200
FULL OPERATING INSTRUCTIONS FOR MODELS AE 50/100 and/or AE 160/200 The single pan electronic balance works off of the theory of a double pan mechanical balance, but is a much faster and unencumbered process.
More informationKERN EG/EW Version /02
E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL
More informationMS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0
User Manual MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0 Thank you for purchasing the Fast Weigh MS-500 digital pocket scale. Please read all operating instructions
More informationAdam Equipment PGL SERIES. (P.N. 9326, Revision C5, March 2009)
Adam Equipment PGL SERIES (P.N. 9326, Revision C5, March 2009) 1 P age Adam Equipment Company 2008 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed
More informationSTANDARD OPERATING PROCEDURE FORCE DIAL FDN 100
Table of Contents 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 2 5. Procedure 3 6. Precautions 5 7. References 5 8. Appendices 5 9. Revision History 5 Page Original Authorised Copy for:
More informationTroubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale
Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Contents Description Refer To: Scale Troubleshooting Chart Troubleshooting Error Codes Error Messages Adjustments / Repair Procedures
More informationAdam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL
Adam Equipment DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL Adam Equipment Company 2002 ADAM EQUIPMENT CO. LTD. pn. 4144 Rev. A, October 2002 Adam Equipment Company
More informationSTANDARD OPERATING PROCEDURE FORCE DIAL FDN 100
Page 1 of 5 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Force Dial FDN 100 in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy Department, University
More informationAdam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL
Adam Equipment DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL ADAM EQUIPMENT CO. LTD. pn. 3478 Rev. E1, September 2000 Adam Equipment Company 2000 Adam Equipment Company
More informationSTANDARD OPERATING PROCEDURE VORTEX-GENIE 2
Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 2 5. Procedure 3 5.1. Installation 3 5.2. Operation 3 5.3. Maintenance 4 5.4. Flow charts 5 6. Precautions 8 7. References
More informationService Manual. Sartorius Expert. LE-Models Electronic Analytical and Precision Balances. WLE5001-e04022
Service Manual Sartorius Expert LE-Models Electronic Analytical and Precision Balances WLE5001-e04022 Table of Contents 04 General Information 04 Fundamentals at a Glance 05 Service Concept for LE Balances
More informationUser Manual. Precision and Analytical Balances ME-T
User Manual Precision and Analytical Balances ME-T Overview balance 0.1 mg 1 mg 9 9 5 7 7 6 4 1 3 2 1 10 mg~0.1 g 2 3 4 5 7 6 12 5 13 1 14 2 3 10 11 8 Balance overview legend 1 Capacitive color TFT touch
More informationSTANDARD OPERATING PROCEDURE
Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 2 5. Procedure 3 6. Precautions 7 7. References 7 8. Appendices 7 9. Revision History 7 Original Authorised Copy for:
More informationBIOGAS COMBUSTION PLANT MAINTENANCE MANUAL
BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL (PLANT MAINTENANCE MANUAL) Puente Gallego Landfill, Rosario (Argentina) ARIA.BIZ S.A. Montevideo 589, 7 floor 1019 Capital federal Argentina Tel: +54 11 5171
More informationOperating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx
Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx Contents 1 Introducing the Pipette Check application... 3 2 important notes... 3 3 Selecting the
More informationEnglish. Quick Guide MS-TS Precision and Analytical Balances
MS MS MS MS English Quick Guide Precision and Analytical Balances 1 Introduction Thank you for choosing a METTLER TOLEDO balance. The precision and analytical balances of the line combine a large number
More informationEPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0
User Manual EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 Thank you for purchasing the American Weigh EPSILON digital kitchen scale. Please read all operating
More informationOperating Instructions Electronic Precision Balances 1 TECHNICAL DATA UNPACKING AND STANDARD EQUIPMENT INSTALLATION...
E KERN 470 Version 1.8 09/2001 Operating Instructions Electronic Precision Balances 1 TECHNICAL DATA...40 2 UNPACKING AND STANDARD EQUIPMENT...40 3 INSTALLATION...41 4 POWER MAINS CONNECTION...41 5 DECLARATION
More informationPegas 4000 MF Gas Mixer InstructionManual Columbus Instruments
Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...
More informationSection 3- Repair and Calibration Procedures
Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration
More informationHART Communications Board
- HART Communications Board (Highway Addressable Remote Transducer) User Manual Document No. Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602
More informationSPS-5. Rate Computing Scale. Operation Manual
SPS-5 Rate Computing Scale Operation Manual Revision 1.0 October 17, 1996 1996 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway Buffalo
More informationTuning Fork Analytical Balance. HT/HTR CEN Series
Tuning Fork Analytical Balance HT/HTR CEN Series Operation Manual IMPORTANT To ensure safe and proper use of the balance, please read this manual carefully. After reading this manual, store it in a safe
More informationBante810 Benchtop Dissolved Oxygen Meter Instruction Manual
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen
More informationWATER CONTROL SYSTEM QUICK START
SETTINGS MENU SYSTEM OPTIONS WATER LEVEL BAR GRAPH 3 DS SPRAY ON/OFF CS SPRAY ON/OFF BEACON WATER CONTROL SYSTEM QUICK START WWW.GFWORLDWIDE.COM +1 (208) 664-9291 SERVICE@GFWORLDWIDE.COM DISPLAY SCREEN
More informationUser Manual. Quantos Automated Dosing Liquid Module
User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if
More informationSAUTER FK Version /2016 GB
Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Tel: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Digital Force Gauge SAUTER FK Version 1.4 12/2016
More informationAll Purpose AP-Series Operation Manual
All Purpose AP-Series Operation Manual CARDINAL SCALE MFG. CO. 8525-M176-O1 Rev J 203 E. Daugherty, Webb City, MO 64870 USA Printed in USA 10/00 Ph: 417-673-4631 Fax: 417-673-2153 www.detectoscale.com
More informationYAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO USA Tel (719) Fax (719)
NTEP CC 08-041 www.yamatocorp.com YAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO 80916 USA Tel (719) 591-1500 Fax (719) 591-1045 YAMATO TECH CORPORATION #112-19425 Langley By-Pass Surrey,
More informationCalibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More information4 - LOAD CELL SCALES - EX VERSION
SAFETY-USAGE MANUAL 4 - LOAD CELL SCALES - EX VERSION WTC/4 600 C6/EX WTC/4 1500 C7/EX WTC/4 1500 C8/EX WTC/4 3000 C8/EX WTC/4 1500 C8/C9/EX WTC/4 3000 C8/C9/EX WTC/4 1500 C9/EX WTC/4 3000 C9/EX WTC/4
More informationSpecifications and information are subject to change without notice. Up-to-date address information is available on our website.
www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp LD302 - AssetView HMI LD302
More informationUser Manual. Quantos Automated Dosing Powder Module
User Manual Powder Module 1 Introduction Thank you for purchasing the Quantos dosing system. Quantos is based on the renowned and reliable XPE series balances from METTLER TOLEDO. Besides the highly accurate
More informationPortable Gas Monitor GX User Maintenance Manual (H4-0050)
H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to
More informationSedan Range. Evaporative Loss System Check Clarified Procedure
SERVICE Sedan Range DATE 3/98 TECHNICAL BULLETIN Evaporative Loss System Check Clarified Procedure 05.1-29 MODEL 1996-97 MY Sedan (4.0L) Range VIN 772231-812255 SWB 776271-812255 LWB ISSUE: A mandatory
More informationTable of contents. Table of contents 1. Installation 2. Introduction ( Display, monitor ) 3. Introduction ( Operating elements ) 4
Table of contents page 1 CONTENTS PAGE Table of contents 1 Installation 2 Introduction ( Display, monitor ) 3 Introduction ( Operating elements ) 4 Introduction ( Result interpretation) 5 Factory default
More informationPERFORM Operating Document
PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More informationHow to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:
How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit: Please read this document thoroughly before attempting to check or adjust the calibration of the formaldehyde sensor within the
More informationOxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument
OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read
More informationPERFORM Operating Document
PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v02 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16
More informationKERN YDB-03 Version /2015 GB
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Universal density determination
More informationINSTRUCTION MANUAL FOR. BPS-series. PrecisionBalances PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
INSTRUCTION MANUAL FOR BPS-series PrecisionBalances PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.02-11.10
More informationSomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings
SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.
More informationSTANDARD OPERATING PROCEDURE
Table of Contents 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 2 5. Procedure 2 6. Precautions 8 7. References 8 8. Appendices 8 9. Revision History 8 Page Original Authorised Copy for:
More informationCopyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic
Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission
More informationCHM Introductory Laboratory Experiment (r17sd) 1/13
CHM 110 - Introductory Laboratory Experiment (r17sd) 1/13 Purpose This introductory exercise will familiarize you with a few of the measurements we make in the chemistry laboratory and the level of uncertainty
More informationDigital Piston Standard
Page 1 / 73 DPG 10-G User's Manual Digital Piston Standard Page 2 / 73 DPG 10G Software version 5.00 Dear user, We would like first to thank you for your confidence in our expertise and products when buying
More informationSTANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER
Page 1 of 8 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Artsana Mercury Sphygmomanometer in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy Department,
More informationOperating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter
O 2 Operating manual Oxi 3205 [Sal] 7.92 25.0 mg/l C 3205 Dissolved oxygen (D.O.) meter ba75797e03 09/2011 Oxi 3205 Accuracy when going to press The use of advanced technology and the high quality standard
More informationStandard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation
Standard Operating Procedure # Chemical Fume Hood Operation Facility: NMSU College of Engineering Laboratories Written by: Juanita Miller, Safety Specialist, miljgh@nmsu.edu (575)-646-1292 Scope: This
More informationTechnical Procedure for Instrument Calibration and Maintenance
Technical Procedure for Instrument Calibration and Maintenance 1.0 Purpose To outline the schedules and procedures involved in the maintenance and verification of critical instrument calibration in the
More informationVapor Sorption Analyzer
Vapor Sorption Analyzer Quick Start Guide 1. Getting Started Place the AquaLab VSA on a flat surface. Use the bubble level(figure 1: Adjustment and bubble level) and use the adjustable feet to level the
More informationMeasurements. Metric System
Measurements Measurements are basic to any scientific pursuit. A measurement has both a magnitude (numeric value) and a unit. Metric units are used in the sciences. Metric System In science, the metric
More informationUSER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND THE USE OF A CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 / 8 Table of csontents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationAutomatic Powder Trickler by Adam MacDonald
Automatic Powder Trickler by Adam MacDonald Instructions for setup and use For Sartorius Entris 64-1S July 2016 For updated instructions and optimization guide, visit the website: www.autotrickler.com
More informationRAM Operation Manual
RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More informationRAM 4021-DPX Operation Manual
RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...
More information955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays
955730_1 4/17/18 FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays Contents System Setup and Operation...3 Configuring Monitor for FlowSense...3 FlowSense Setup...4 Liquid Alerts...8 Monitoring
More informationSCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties
Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationImprove Process Reliability
Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories
More informationQuick Installation Guide Doc nr.: C Date:
Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationScoreboard Operator s Instructions MPC Control
Scoreboard Operator s Instructions MPC Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 Retain this manual in your permanent files 1/21/2011
More informationPTG100 Precision Test Gauge
PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:
More informationDOscan10 Pocket Dissolved Oxygen Tester Instruction Manual
DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual BANTE INSTRUMENTS CO., LTD DOscan10 Pocket Dissolved Oxygen Tester 1 Thank you for selecting the DOscan10 pocket dissolved oxygen tester. This
More informationACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH
ACCUSTRIDE Digital Clip-on Pedometer WC153 ACCUSTRIDEFM Digital Clip-on Pedometer WC154 ENGLISH CONTENTS INTRODUCTION USE OF PEDOMETER 4 BASIC FEATURE 5 TIME MODE 7 WALK / RUN MODE 9 MEMORY MODE 11 USER
More informationDigital Melting Point Apparatus
Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature
More informationHeavy Duty Dissolved Oxygen Meter
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations
More informationOperator Quick Guide ORBISPHERE 3654
Operator Quick Guide ORBISPHERE 3654 Revision H - 14/03/2008 Operating Information About this Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach
More informationRelative Humidity Calibration Kit
Revised 1.4.11 Relative Humidity Calibration Kit For Calibrating All RH Measuring Kestrel Meters Model Numbers 3000, 3500, 4000, 4100, 4200, 4250, 4300, 4500 While the calibration process is very simple,
More informationAPA software instruction manual
1. Starting the program In order to start the control software for the APA device press APAxx shortcut located on the desktop of the supplied computer. XX corresponds to the current software version. When
More informationSartorius Competence CP Series Sartorius Gem plus
Service Manual Sartorius Competence CP Series Sartorius Gem plus CP, GC and GP-Models Electronic Semimicro-and Analytical Precision Balances and Precious Metal Scales Including Service Specifications Sheets
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationInstallation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22
Arrow Valves Ltd Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22 Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Model shown
More informationREASONS FOR THE DEVELOPMENT
7 Series 7 Series +24VDC VDC OUTPUT MICROPROCESS. E P IN EXH OUT 7 Series 7 ø,8 8 7 Series 9 5 8 9 7 Series Display features The proportional regulator has a 3 /2 digit display and a three-pushbutton
More informationGeneral Accreditation Guidance. User checks and maintenance of laboratory balances
General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationNavigator 600 Silica analyzers
ABB MEASUREMENT & ANALYTICS INFORMATION INF09/020 REV. B Navigator 600 Silica analyzers Troubleshooting Measurement made easy Navigator 600 silica analyzers 1 Introduction This publication details troubleshooting
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter. Model
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationAll Sport 5000 Control Console
All Sport 5000 Control Console Operations Manual ED-11976 Rev 16 10 September 2007 ED-11976 Product 1196 Rev 16 10 September 2007 DAKTRONICS, INC. Copyright 2003-07 All rights reserved. While every precaution
More informationRAM 4021 Operation Manual
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6
More informationTitle: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator
Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality
More informationAMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310. Operating Manual
AMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310 Operating Manual (PAS 7 UP) Inscale Measurement Technology Ltd Unit 2, Hazel House, 78 London Road, Bexhill. East Sussex TN39 3LE United Kingdom Tel:+44(0)1424
More informationHemoglobin Reference Failure Troubleshooting
Hemoglobin Reference Failure Troubleshooting The HEMOGLOBIN REFERENCE FAILURE error ( HGB REF FAILURE ) is generated by the Vet ABC as a quality control check for hemoglobin measurement. Recall that the
More information