50Hz. water solutions. O SerieS DGO DRO

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "50Hz. water solutions. O SerieS DGO DRO"

Transcription

1 Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN

2

3 water solutions O SerieS DGO DRO Hz D a t a b o o k l e t

4 O SERIES O Series General characteristics AISI stainless steel lifting and carrying handle Constructed in GJL- cast iron One mechanical seal in silicon carbide (SiC) and one mechanical seal in alumina graphite (AL) Oil bath motor with thermal protections Capacitor and overload protection in external cabinet. Threaded, flanged discharge for the maximum ease of installation Wide free allowing the expulsion of solids and preventing fouling of the impeller (DGO) Intake strainer in stainless steel (DRO) Hydraulic families DG (Draga) Set-back vortex impeller Suitable for heavy-duty applications with soiled biological wastewaters, sewage, rainwater and seepage page 7 DR (Dreno) page Multi-channel open impeller Can be used with clear or slightly soiled wastewaters containing small solids, strained water, rainwater, seepage and water pumped from underground. Suitable for heavy-duty domestic and professional applications Operating ranges DGO DRO H(m) 6 H(m) Q(l/min) Q(m /h) Q(l/min) Q(m /h) DATA BOOKLET

5 O SERIES Versions available Electrical variants Single-phase models T TCST TCSGT Thermal protection Thermal protection, capacitor, electrical cabinet, overload protection Thermal protection, capacitor, float switch, electrical cabinet, overload protection Three-phase models NAE No electric accessories installed Cooling system N No cooling and/or seal flushing system Set of mechanical seals SICAL mechanical seal in silicon carbide and mechanical seal in alumina graphite (NBR) Key to product code DRO //GV ABM (A) (B) (C) Family Series 6 Power (HPx) / motor poles 7 Delivery rate (A) TYPE (GAS thread/flanged) 8 (B) DIAMETER (mm) (C) POSITION V = vertical 9 H = horizontal Hydraulic model Version number Motor size Motor phases M = Single-phase T = Three-phase Power supply voltage frequency = Hz 6 = 6Hz ZENIT.COM

6 O SERIES Installations installation The electric pump, standing on its feet or base, is connected to the delivery flexible pipe using a joint fixed to the discharge. This installation allows to move easily the electrical pump Fixed installation The electric pump, standing on its feet or base, is connected to the delivery pipe, which is screwed to the discharge if threaded, or fixed to a bend if the port is flanged. The pump-hose connection may be threaded or flanged, depending on the pump fitting. Installation with external coupler Available for electric pumps with threaded discharge. The pump unit is supported by a special device fitted to the delivery pipe. This device can be installed at any time without having to empty the tank. It simplifies any maintenance work on the pump, which can be lifted out and resubmerged with great ease. It is recommended in particular for installations of small size, and does not require the pump to be resting on the bottom of the tank. Installation with base coupling foot For submerged installation, available for electric pumps with flanged or threaded horizontal discharge. The coupling device is fixed to the bottom of the tank and the pump is lowered in with the aid of two guide pipes fitted earlier, until the connection to the foot is completed. The delivery pipe is fixed to the coupling device discharge. This device makes routine checks, any maintenance work or replacement of the pump extremely easy, with no need to empty the tank. A specific kit also allowing pumps with vertical discharge to be installed with the base coupling foot is available. 6 DATA BOOKLET

7 Vortex IMPELLER DGO Pumps with vortex impeller Operating ranges H(m) Q(l/min) Q(m /h) Range characteristics Motor power.7. kw Poles / Insulation class F Degree of protection IP68 Discharge GAS ½ ½ vertical GAS DN horizontal DN6 DN8 horizontal max 8 mm Max flow rate 9. l/s ( l/min) Max head 7. m Motor Oil bath motor with thermal protections. Cable H7RN-F - m cable length. Optional m cable length. Mechanical seals One silicon carbide mechanical seal (SiC) and one carbon-aluminium oxide mechanical seal (AL) Applications Suitable for heavy-duty applications with soiled biological wastewaters, sewage, rainwater and seepage. Versions Electrical variants Cooling system Mechanical seals Operating specifications Max operating temperature PH of treated fluid Viscosity of treated fluid Maximum immersion depth Density of treated fluid Acoustic pressure max Max starts per hour Construction materials T, TCST, TCSGT (single-phase models) NAE (three-phase models) N SICAL C 6 mm /s m Kg/dm <7dB Case Cast iron EN-GJL Hydraulic parts Cast iron EN-GJL Impeller Cast iron EN-GJL Nuts and bolts Stainless steel - Class A-7 Standard gasket Rubber - NBR Shaft Stainless steel - AISI Paint type Ecological bicomponent epoxy (~ 8 μm) Installations FREE FIXED with EXTERNAL COUPLER with BASE COUPLING FOOT ZENIT.COM 7

8 Vortex IMPELLER DGO /GV Performances l/s 6 8 l/min 6 8 m /h DGO //GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) H (m) Q (l/min) Q (m /h) Characteristic curves according to UNI EN ISO 996 Technical data V Phases P (kw) P (kw) A Rpm Start DGO //GV BCM Dir G G ½ mm DGO //GV BCM Dir G G ½ mm DGO //GV BCM Dir G G ½ mm Cable Ø V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GV BCT Dir G G ½ mm DGO //GV BCT Dir G G ½ mm DGO //GV BCT Dir G G ½ mm 8 DATA BOOKLET

9 Vortex IMPELLER DGO /GV Performances l/s 6 8. l/min m /h DGO //GV BCM(T) 6... DGO 7//GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) H (m) 6 Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GV BCM Dir G G mm DGO 7//GV BCM Dir G G mm DGO //GV BCM Dir G G mm DGO //GV BCM Dir G G mm DGO //GV BCM Dir G G mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GV BCT Dir G G mm DGO 7//GV BCT Dir G G mm DGO //GV BCT Dir G G mm DGO //GV BCT Dir G G mm DGO //GV BCT Dir G G mm ZENIT.COM 9

10 Vortex IMPELLER DGO /GH Performances l/s 6 8 l/min m /h DGO //GH ACM(T) DGO 7//GH ACM(T) DGO //GH ACM(T) DGO //GH ACM(T) DGO //GH ACM(T) H (m) Q (l/min) Q (m /h) Characteristic curves according to UNI EN ISO 996 Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GH ACM Dir G G - DN mm DGO 7//GH ACM Dir G G - DN mm DGO //GH ACM Dir G G - DN mm DGO //GH ACM Dir G G - DN mm DGO //GH ACM Dir G G - DN mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GH ACT Dir G G - DN mm DGO 7//GH ACT Dir G G - DN mm DGO //GH ACT Dir G G - DN mm DGO //GH ACT Dir G G - DN mm DGO //GH ACT Dir G G - DN mm DATA BOOKLET

11 Vortex IMPELLER DGO /G6V Performances l/s 6 8. l/min m /h DGO //G6V ACM(T) DGO //G6V ACM(T) H (m) 8 Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //G6V ACM Dir G G ½ 6 mm DGO //G6V ACM Dir G G ½ 6 mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //G6V ACT Dir G G ½ 6 mm DGO //G6V ACT Dir G G ½ 6 mm ZENIT.COM

12 Vortex IMPELLER DGO /6 Performances l/s 6 8 l/min m /h DGO //6 ACM(T) DGO //6 ACM(T) H (m) 8 6 Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //6 ACM Dir G DN6 6 mm DGO //6 ACM Dir G DN6 6 mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //6 ACT Dir G DN6 6 mm DGO //6 ACM Dir G DN6 6 mm DATA BOOKLET

13 Vortex IMPELLER DGO /8 Performances l/s l/min m /h DGO //8 ACM(T) H (m) 8 Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //8 ACM Dir G DN8 8 mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //8 ACT Dir G DN8 8 mm ZENIT.COM

14 Vortex IMPELLER DGO /GV Performances l/s 6 8 l/min 6 8 m /h DGO //GV BCM(T) H (m) Characteristic curves according to UNI EN ISO 996 Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GV BCM -.7. Dir G G mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GV BCT Dir G G mm DATA BOOKLET

15 Vortex IMPELLER DGO /GH Performances l/s l/min m /h DGO //GH ACM(T) H (m) Characteristic curves according to UNI EN ISO 996 Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GH ACM Dir G G -DN mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //GH ACT -.7. Dir G G -DN mm ZENIT.COM

16 Vortex IMPELLER DGO /6 Performances l/s 6 8 l/min m /h DGO //6 ACM(T) H (m) 6 Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //6 ACM Dir G DN6 mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //6 ACT Dir G DN6 mm 6 DATA BOOKLET

17 Vortex IMPELLER DGO /8 Performances l/s l/min m /h DGO //8 ACM(T) H (m) Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //8 ACM Dir G DN8 6 mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DGO //8 ACT Dir G DN8 6 mm ZENIT.COM 7

18 Vortex IMPELLER DGO Overall dimensions and weights Models with vertical discharge A B C D E E F DGO //GV BCM(T) 6 G ½ - 8 DGO //GV BCM(T) 6 G ½ - 9 DGO //GV BCM(T) 6 G ½ - DGO //GV BCM(T) 8 8 G DGO 7//GV BCM(T) 8 8 G DGO //GV BCM(T) 7 G - 9. DGO //GV BCM(T) 7 G -. DGO //GV BCM(T) 7 G -. DGO //G6V ACM(T) G ½ xm8 Ø6 DGO //G6V ACM(T) G ½ xm8 Ø6 DGO //GV BCM(T) 7 G - Dimensions in mm Models with horizontal discharge A B C D E F G H J J DGO //GH ACM(T) G - DN DGO 7//GH ACM(T) G - DN DGO //GH ACM(T) 7 G - DN DGO //GH ACM(T) 7 G - DN DGO //GH ACM(T) 7 G - DN DGO //GH ACM(T) 7 G - DN Dimensions in mm 8 DATA BOOKLET

19 Y Vortex IMPELLER DGO DN PN -6 A B C D E E F G H J J DGO //6 ACM(T) xm8 Ø DGO //6 ACM(T) xm8 Ø DGO //8 ACM(T) xm8 Ø DGO //6 ACM(T) DGO //8 ACM(T) Dimensions in mm Packaging dimension X Z X Y Z DGO //GV BCM(T) 8 7 DGO //GV BCM(T) 8 7 DGO //GV BCM(T) 8 7 DGO //GV BCM(T) 8 DGO 7//GV BCM(T) 8 DGO //GV BCM(T) 8 7 DGO //GV BCM(T) 8 7 DGO //GV BCM(T) 8 7 DGO //GH ACM(T) 8 DGO 7//GH ACM(T) 8 DGO //GH ACM(T) 8 7 X Y Z DGO //GH ACM(T) 8 7 DGO //GH ACM(T) 8 7 DGO //G6V ACM(T) 8 7 DGO //G6V ACM(T) 8 7 DGO //6 ACM(T) 8 DGO //6 ACM/(T) 8 DGO //8 ACM(T) 8 DGO //GV BCM(T) 8 7 DGO //GH ACM(T) 8 7 DGO //6 ACM(T) 8 DGO //8 ACM(T) 8 Dimensions in mm ZENIT.COM 9

20 Multi-channel open impeller DRO Pumps with multi-channel open impeller Operating ranges H(m) Q(l/min) Q(m /h) Range characteristics Motor power.7. kw Poles Insulation class F Degree of protection IP68 Discharge GAS ¼ vertical GAS DN horizontal max mm Max flow rate. l/s (78 l/min) Max head 8. m Motor Oil bath motor with thermal protections. Cable H7RN-F G - m cable length. Optional m cable length. Mechanical seals One silicon carbide mechanical seal (SiC) and one carbon-aluminium oxide mechanical seal (AL) Applications Can be used with clear or slightly soiled wastewaters containing small solids, strained water, rainwater, seepage and water pumped from underground. Versions Electrical variants Cooling system Mechanical seals Operating specifications Max operating temperature PH of treated fluid Viscosity of treated fluid Maximum immersion depth Density of treated fluid Acoustic pressure max Max starts per hour Construction materials T, TCST, TCSGT (single-phase models) NAE (three-phase models) N SICAL C 6 mm /s m Kg/dm <7dB Case Cast iron EN-GJL Hydraulic parts Cast iron EN-GJL Impeller Cast iron EN-GJL Nuts and bolts Stainless steel - Class A-7 Standard gasket Rubber - NBR Shaft Stainless steel - AISI Paint type Ecological bicomponent epoxy (~ 8 μm) Installations FREE FIXED with EXTERNAL COUPLER with BASE COUPLING FOOT DATA BOOKLET

21 Multi-channel open impeller DRO /GV Performances l/s 6 l/min m /h DRO //GV ACM(T) DRO 7//GV ACM(T) H (m) Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GV ACM Dir G G ¼ mm DRO 7//GV ACM Dir G G ¼ mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GV ACT Dir G G ¼ mm DRO 7//GV ACT Dir G G ¼ mm ZENIT.COM

22 Multi-channel open impeller DRO /GV Performances l/s 6 8 l/min m /h DRO //GV ACM(T) DRO //GV ACM(T) DRO //GV ACM(T) H (m) Q (l/min) Q (m /h) Characteristic curves according to UNI EN ISO 996 Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GV ACM Dir G G mm DRO //GV ACM Dir G G mm DRO //GV ACM Dir G G mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GV ACT Dir G G mm DRO //GV ACT Dir G G mm DRO //GV ACT Dir G G mm DATA BOOKLET

23 Multi-channel open impeller DRO /GH Performances l/s 6 8 l/min m /h DRO //GH ACM(T) DRO //GH ACM(T) DRO //GH ACM(T) H (m) Characteristic curves according to UNI EN ISO Q (l/min) Q (m /h) Technical data V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GH ACM Dir G G mm DRO //GH ACM Dir G G mm DRO //GH ACM Dir G G mm V Phases P (kw) P (kw) A Rpm Start Cable Ø DRO //GH ACT Dir G G mm DRO //GH ACT Dir G G mm DRO //GH ACT Dir G G mm ZENIT.COM

24 Y Multi-channel open impeller DRO Overall dimensions and weights Models with vertical discharge Models with horizontal discharge A B C D E F DRO //GV ACM(T) 7 G ¼ DRO 7//GV ACM(T) 7 G ¼. DRO //GV ACM(T) G 9 9. DRO //GV ACM(T) G 9. DRO //GV ACM(T) G 9. Dimensions in mm A B C D E F G H J DRO //GH ACM(T) G -DN DRO //GH ACM(T) G -DN DRO //GH ACM(T) G -DN Dimensions in mm Packaging dimension X Z X Y C DRO //GV ACM(T) 8 DRO 7//GV ACM(T) 8 DRO //GV ACM(T) 8 7 DRO //GV ACM(T) 8 7 DRO //GV ACM(T) 8 7 DRO //GH ACM(T) 8 7 DRO //GH ACM(T) 8 7 DRO //GH ACM(T) 8 7 Dimensions in mm DATA BOOKLET

25 O SERIES Hydraulic performance data For quick, easy reference DGO l/s l/min m /h DGO //GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) 6... DGO 7//GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) DGO //GV BCM(T) DGO //GH ACM(T) DGO 7//GH ACM(T) DGO //GH ACM(T) DGO //GH ACM(T) DGO //GH ACM(T) DGO //G6V ACM(T) DGO //G6V ACM(T) DGO //6 ACM(T) DGO //6 ACM(T) DGO //8 ACM(T) DGO //GV BCM(T) DGO //GH ACM(T) DGO //6 ACM(T) DGO //8 ACM(T) DRO DRO //GV ACM(T) l/s 6 8 l/min m /h DRO 7//GV ACM(T) DRO //GV ACM(T) DRO //GV ACM(T) DRO //GV ACM(T) DRO //GH ACM(T) DRO 7//GH ACM(T) DRO //GH ACM(T) DRO //GH ACM(T) DRO //GH ACM(T) ZENIT.COM

26 O SERIES Notes 6 DATA BOOKLET

27

28 water solutions All data made available remain non-binding. Zenit reserves the right to make unannounced product changes it deems appropriate. Rev. - //7

Zenit. Blue Professional Series. Submersible Electric Pumps.

Zenit. Blue Professional Series. Submersible Electric Pumps. Zenit Blue Professional Series Submersible Electric Pumps 1 7 1 www.zenitpumps.com.au A range of submersible pump models innovatively designed and manufactured for industrial, heavy duty use. Meeting the

More information

Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series

Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series Submersible pumps for clean and slightly dirty water manufactured in AISI 304 stainless steel. Head up to 20 metres,

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE

More information

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments The first choice for high water and flooding. Rosenbauer NAUTILUS submersible pump NAUTILUS.

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Submersible Pumps Product Overview

Submersible Pumps Product Overview TM/TMW 32 Duty chart (2 -pole, 50 Hz) H[m] 10 8 6 TM/TMW 32 Submersible Pumps Product Overview Submersible Pumps Basement drainage pump Applications: Pumping clear or slightly soiled water from tanks,

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES. Cod.

50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES. Cod. Hz GS-GS1-GS3 Series FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES Cod. 19191 Rev ev.b.b Ed./1 CONTENTS General introduction... Choice and selection...

More information

EnerVal. Technical data litre storage capacity. Buffer storage vessels

EnerVal. Technical data litre storage capacity. Buffer storage vessels EnerVal Buffer storage vessels Technical data 200-10000 litre storage capacity Contents Title Page number EnerVal (200-2000) Description 3 Part No. 4 Technical data 6 Dimensions 7 EnerVal G (1000-10000)

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

Seated valves VRB 3, VRG 3

Seated valves VRB 3, VRG 3 Data sheet Seated valves VRB 3, VRG 3 Description VRB, VRG valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol concentrations

More information

Materials : Galvanized steel flanges

Materials : Galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 200 Flanges PN10/16-10 C + 80 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noises Linear and angular compansion Single NBR

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Domestic water supply

Domestic water supply GRUNDFOS PRODUCT GUIDE Domestic water supply BMQE, MQ, Jets 6 z Domestic water supply Table of contents 1. Grundfos DWS family 3 DWS applications 3 DWS product selection 4 2. BMQE 5 Product introduction

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

PRESSURE REDUCING VALVE EUROBRASS 143 FF

PRESSURE REDUCING VALVE EUROBRASS 143 FF Scheda prodotto Eurobrass 143 ENG Rev. 5 09/2012 PRESSURE REDUCING VALVE EUROBRASS 143 FF Direct acting brass pressure reducing valve; PN 25; Adjustable outlet pressure between 0,5 and 6 bar; Brass diaphragm

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg.

WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg. MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - AND Kg. 01 AIR OPERATED OIL PUMPS AND KITS Iquip modit iriuscidunt nos niam ver ip AIR OPERATED PISTON PUMPS FOR OIL AND LUBRICANTS............... 000...

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

Spare parts list ( ) Spare parts list HDS 990

Spare parts list ( ) Spare parts list HDS 990 Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

GS20-GS21-GS30 Series

GS20-GS21-GS30 Series GS-GS1-GS3 Series Fixed-speed pressure booster sets with Horizontal Centrifugal electric pumps FH and SH series Hz WEB 1-1 CONTENTS General introduction... Choice and selection... 13 GS.../FH Series...13

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved

More information

Spare parts list ( ) Spare parts list HD 2.3/15 C Ed/ 3.0/20

Spare parts list ( ) Spare parts list HD 2.3/15 C Ed/ 3.0/20 Spare parts list (5.970-616.0) Spare parts list HD 2.3/15 C Ed/ 3.0/20 23.09.2011 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HD 2.3/15 C Ed/ 3.0/20 (5.970-616.0)... 6 10

More information

FIREFIGHTING EQUIPMENT

FIREFIGHTING EQUIPMENT FIREFIGHTING EQUIPMENT User Manual ANTENOR 3000 Base or portable Trailer DOC 1974 En Rev.B - 22/10/13 Tel : 03 25 39 84 78 - Fax : 03 25 39 84 90 - Email : france@pok.fr - Web : www.pok.fr Identification

More information

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

BUTTERFLY VALVES. Toll Free (877) - ICFLUID  -2- BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut

More information

Workshop Compressors CLASSIC Series

Workshop Compressors CLASSIC Series www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only by using

More information

KTM 50 (DN ) Installation, maintenance and operating instructions

KTM 50 (DN ) Installation, maintenance and operating instructions 52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions General High-performing and compact, these pressure-independent control valves for variable flow heating and

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

STAP. Differential pressure controller DN

STAP. Differential pressure controller DN STAP Differential pressure controller DN 65-100 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE The flanged STAP is a high-performing differential pressure

More information

TW Temperature Control Valve

TW Temperature Control Valve 0470050/6 IM-P047-04 CH Issue 6 TW Temperature Control Valve Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Maintenance 5. Spare parts

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Flat roof drainage 1

Flat roof drainage 1 Flat roof drainage 1 F Ü R D I E ZU K U N FT G E DAC HT. alwitra waterproofing system Flat roof drainage systems are part of the proven alwitra waterproofing system. This system comprises: 1 Waterproofing

More information

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous

More information

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 24.06.2016 www.kaercher.com EN Page 2 / 51 Page 3 / 51 Page 4 / 51 Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0)

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

Workshop Compressors CLASSIC Series

Workshop Compressors CLASSIC Series www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using

More information

Process Pump. Series PAF3000/Series PAF5000

Process Pump. Series PAF3000/Series PAF5000 Process Pump Series 3/Series The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance have

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

VK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010

VK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010 VK/VP SERIES : Sealless Vertical Pump Assembling Instructions 2010 20610 Manhattan Place Suite 116 Torrance, CA 90501 Phone: 310-328-9114 Fax: 310-328-9441 1. Motor Shaft and Pump Base (1) (2) Place a

More information

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance

More information

Keel-stepped and deck-stepped masts,

Keel-stepped and deck-stepped masts, Keel-stepped and deck-stepped masts, C-sections and F-sections The T-base and deck ring systems are made to fit both Seldén s conventional mast sections and their matching furling sections. They are also

More information

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Ref GAS WAFER BUTTERFLY VALVE.  Model/Ref: Model/Ref: 1141 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 32/40 to 200 mm Between ISO PN10/16 and ANSI150 flanges - 20 C + 60 C Max Pressure : 5 Bars Specifications

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Operating instruction

Operating instruction Operating instruction MV, XV, HG, HP, RKO, D2G, TV, BV, WB & SLV 1 Introduction 2 2 Stafsjö s knife gate valves 2 3 Technical information 2 3.1 Pressure test 2 3.2 Labelling 2 4 Storage 3 5 Transportation

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

Knife Gate Valves Pricelist 2017

Knife Gate Valves Pricelist 2017 Knife Gate Valves list 2017 Range of Knife Gate Valves * Manual and Actuated Knife Gate Valves * Accessories * Stafsjo Knife Gate Valves Knife Gate Valves list 2017 About Us All Valves Online Ltd are a

More information

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2 NPT - 2 NPT. SV/614 Series SV-DLE/614 Series SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435 Instruction manual Bermad surge anticipation manual Model No 435 Installation and operation Manual Bermad Surge Anticipation Valve Model No 435 Bermad Water Technologies Rev 0 5/05/2015 7 Inglewood Drive,

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS SA INTRODUCTION These instructions are for the maintenance personnel for maintenance and repair of compressors series SA. Disassembly and

More information

STAD. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50 STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated AquaDDM Direct-Drive Mixer Often Imitated Never Duplicated AquaDDM Mixer Proven mixing efficiency The AquaDDM Mixer is designed to provide maximum mixing efficiency. For those applications where mixing

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance

More information

ProcessMaster FEP610 Electromagnetic flowmeter

ProcessMaster FEP610 Electromagnetic flowmeter Change from one to two columns Data Sheet DS/FEP61-EN Rev. A ProcessMaster FEP61 Electromagnetic flowmeter The new flowmeter: The first choice for all industrial standard applications. Measurement made

More information

3-port seat valves with externally threaded connection, PN 16

3-port seat valves with externally threaded connection, PN 16 4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA Official homologation by the European laboratory CSTB according to NF EN12101-3: 2002 CTH Centrifugal roof 400ºC/2h CTH (horizontal) Roof cowl made of polyethylene UV resistant. Structure, roof base support

More information

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin New! ProFlow Sliding Vane Meters DN 15-5 (½ - 2 ) _ 142 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments ProFlow positive displacement sliding vane type liquid flowmeters are used in continuous

More information

Accessories. Flexible Compensators FN & ESA FLEX & INOXESTENS (E5603 rev /03/2015)

Accessories. Flexible Compensators FN & ESA FLEX & INOXESTENS (E5603 rev /03/2015) Accessories Flexible Compensators FN & SA FLX & INOXSTNS (5603 rev. 03-23/03/2015) GNRAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff,

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

CYL KNIFE GATE VALVES San Sebastian Spain

CYL KNIFE GATE VALVES San Sebastian Spain CYL KNIFE GATE VALVES San Sebastian Spain INSTALATION, OPERATION & MAINTENANCE INSTRUCTIONS (XD HIGH PRESSURE) INTRODUCTION The CYL knife gate valve is a unique, patented, low cost, bi-directional on-off

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Goulds 3296 EZMAG. Chemical Process Pump

Goulds 3296 EZMAG. Chemical Process Pump Goulds 3296 EZMAG Chemical Process Pump 3296 EZMAG Chemical Process Pump Capacities to 700 gpm (160 m3/h) Heads to 620 ft (189 m) Temperatures to 535 F (280 C) Pressures to 275 PSIG Performance Features

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

FILTON SWIVEL JOINTS. technical manual

FILTON SWIVEL JOINTS. technical manual SWIVEL JOINTS technical manual FILTON SWIVEL JOINTS AN INTRODUCTION What are Swivel Joints? Swivel Joints are sealing devices which allow the leakproof transfer of fluid to and from slow and intermittent

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information