DMW. Direct Mass Flow Meter and Controller. for Gases. Measuring ranges from Nl/min air. Accuracy: ±3% of full scale
|
|
- Emerald Young
- 6 years ago
- Views:
Transcription
1 Direct Mass low Meter and ontroller for Gases measuring monitoring analysing DMW Measuring ranges from Nl/min air Accuracy: ±3% of full scale p max : 10 bar; t max : 50 onnections: G ¼, G ½, G1 Sensor housing: Aluminium or stainless steel S5 Output: 4-20 ma, 0-5 V D Quick response time Insensitive to soiling and humidity KOOLD companies worldwide: ARGENTINA, AUSTRIA, ELGIUM, ULGARIA, ANADA, HILE, HINA, OLoMIA, ZEHIA, DOMINIAN REPULI, EGYPT, RANE, GERMANY, GREAT RITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXIO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOOLD Messring GmbH Nordring D Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com 1
2 Description The new model DMW-... direct mass has been specially designed for use in gas measuring technology. An inexpensive analogue output is fitted. The model DMW is available in three versions: with or without integrated 3 ½-digit LD display or with a 8-digit counter. The direct stream procedure is ideally suited for measurements from 0,5 Nl/min (max.) up to 6000 Nl/min air (model: DMW-*786). In case of small flow rates the measurements are taken with a bypass-system (DMW-A/). In contrast with most volumetric s the mass flow meter DMW-... has no moving parts, and no temperature or pressure correction is required. The meter may be installed in any position and the pressure loss is negligible. The simple mechanical construction ensures the highest degree of reliability when used with aggressive gases, and under tough industrial service conditions. Application examples Monitoring of gases ounted consumption for accounting reason Varnishing facility oating facility Semiconductor industry Laboratories and research Gas indication panels Mechanical engineering N 2 /O 2 generators urner controller Technical Data Measuring system: and ypass Measuring range: % Gas type: all gases and gas mixtures, depending on the combatibility with wetted parts Accuracy (with calibration for air): ±3 % of full scale incl. non-linearity Repeatability: ±0.5 % of full scale (others on request) Time constant (63.2%): τ = 0.7 s (ypass) τ = 2 s (direct stream) Display: 3 ½-digit LD (flow rate); 8-digit LD (counter) Pressure coefficient: 0.3 % of actual value / bar typically (air) Temperature coefficient:± 0.3 % of actual value / (air) Temperature: Pressure: 10 bar; higher on request Leakage rate: <2 x 10-7 mbar l /s He Preheating time: 30 minutes for optimal accuracy; 30 s for accurcy ±4% of full scale Mounting position: any, flow rate in arrow direction Inlet section: not necessary kv s -values controller: 0.066; (DMW-) 0.066; 0.3; 1.0; 2.8; 3.4; 4.4 (DMW-D) Materials Sensor: asing: ilter/rings: Seal: Stainless steel 316L Stainless steel 316L or Aluminium (anodized) Stainless steel 304 /PTE PM, EPDM or KM Power supply: 24 V D ±10% 15 V D ±10% on request Max. current values DMW-A/: DMW-/D: With valve control: Signal input (with controller only): Signal output: onnector: Protection: 75 ma max. current input 250 ma max. without flow 75 ma max. 100% flow rate 175 ma max ma max. Poti, V D or ma V D or ma aktive round pin plug/opposite plug, 6-pole DIN IP 40; IP 65 (option) 2
3 Technical Data (continuation) Special design (on request): dry and oil-free for O 2 version digital design on request Special calibration (on request): for example: A 2, O 2, H 2, He, N 2 Informations for request and order To be able to find out the suitable instrument for your application, we ask for the following technical details: Gas type, measuring range Operating temperature and pressure (for controller, upstream and downstream pressure) Required output signal Seals ased on this information, the following calculations or examinations are carried out: onverting of the desired gas-flow in the air equivalent for the dimensioning of the units. Only for controller: Examination, whether the pressure difference over the valve (ΔP) is an acceptable range. Only for controller: Examination, whether the calculated KV-value is inside the specification. Order Details mass (Example: DMW-A71 12 G2 3 2) Measuring system Measuring tube Sensor housing Aluminium St. steel Measuring range [Nl/min air]* onnection ypass small DMW-A71... DMW-A = Nml/min = Nml/min = = = = = mm DMW DMW = mm DMW DMW = mm DMW DMW = mm DMW DMW = = mm DMW DMW = Nm 3 /min = Nm 3 /min = Nm 3 /min..g6.. = G 1 female 84 mm DMW DMW = Nm 3 /min = Nm 3 /min..g6.. = G 1 female * Nl = Norm Litre at 1013 mbar and 0 l S = Standard Litre at 1013 mbar and 20 (others on request) Order Details mass (continued) Seal Indication/protection Output Measuring ranges also available in Nm³/min, Nm³/h, Nl/h or others.... = PM..E.. = EPDM..P.. = KM = without indication, IP = without indication, IP65..D.. = flow rate indication, IP40..Z.. = counter, IP40..2 = 0-5 V D..4 = 4-20 ma 3
4 Order Details mass flow controller (Example: DMW G2 3 2) Measuring system ypass ypass Measuring tube Sensor housing Aluminium St. steel small DMW DMW medium DMW DMW mm DMW-D70... DMW-D mm DMW-D71... DMW-D mm DMW-D72... DMW-D mm DMW-D73... DMW-D23... Measuring range* [Nl/min air] = Nml/min = Nml/min = = = = = = = = = = = onnection *Mass flow controller for higher measuring ranges on request Order Details mass flow controller (Example: DMW G2 3 2) Seal Indication/Protection Input/Output... = PM..E.. = EPDM..P.. = KM..3..= without indication, IP = without indication, IP65..D..= flow rate indication, IP40..Z..= counter, IP40..2 = 0-5 V D..4 = 4-20 ma..6 = Poti /0-5 V D (up to 100 l/min)..8 = Poti /4-20mA (up to 100 l/min) Pressure loss diagram DMW-*0 DMW-*1 DMW-*3 DMW-*2 DMW-* DMW-*8 100 P (mbar) low Durchfluss rate air Luft (Nl/min) 4
5 Dimensions [mm] DMW-A..., DMW-*0..., DMW-*1..., DMW-*2... Model G Display Anzeige optional optional DMW-A... G ¼ G ¼ DMW-*0.. G ¼ G ¼ DMW-*1... G ¼ G ¼ DMW-*2... G ½ G ½ G (mit (with Anzeige) display) DMW-*3..., DMW-*5..., DMW-*8... Model A D E G H DMW-* G ½ G ½ DMW-* G 1 G DMW-* G 1 G Display Anzeige optional optional H G (with (mit Anzeige) display) D A 5
6 DMW-*1..., DMW-*2..., DMW-D*0..., DMW-D*1... Model A D G H DMW-* G ¼ G ¼ DMW-* G ½ G ¼ DMW-D* G ¼ G ¼ Display Anzeige optional DMW-D* G ¼ G ¼ H G (with (mit Anzeige) display) DMW-D*2..., DMW-D*3... D A Model A D G H DMW-D* G ½ G ½ DMW-D* G ½ G ½ Dimensions upon request Display Anzeige optional G I H D A 6
Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW
Operating Instructions for Direct Flow Mass Flow Meter for gases Model: DMW 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 5.1.
More informationKMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N
Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :
More informationThermal Energy Flowmeter Model KEC. Application Range. Special Features
Thermal Energy Flowmeter for gases measuring monitoring analysing KEC O O Direct mass flow rate measurement of gases OMeasuring O accuracy: ± 0.3% of full scale ±1.5% of reading on request: ± 0.3% of full
More informationKMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h
Thermal Mass Flowmeter for compressed air and gases measuring monitoring analysing KMT Measuring range: 0.32... 63 Nm³/h - 263.4... 263350 Nm³/h Accuracy: ± 1.5% of reading + 0.5% of full scale ( DN 50)
More informationSCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel
Diaphragm Pressure Switch measuring monitoring analysing SCH-27 P3 Setting range: 0.7... 6 mbar to 8... 160 bar Temperature: max. +100 C Material: stainless steel Connection: G ½ male, ½" NPT male, ¼"
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationRCD. Differential Pressure Flowmeters. for Liquids or Gases
ifferential Pressure Flowmeters for Liquids or Gases measuring monitoring analyzing R Measuring Ranges: 0.2...0.88 to 100...600 GPM (Water) 0.3...3.0 to 250...1650 SFM (Air) Accuracy: ± 3% of Full Scale
More informationFloat Switches. for Liquids NSM, NSP, NAB, NEC, NST, NSE
Float Switches for Liquids measuring monitoring analysing NSM, NSP, NAB, NEC, NST, NSE Easy to install Suited for universal use p max : 15 bar; t max : 150 C PP, PTFE, stainless steel 3 From density 0.5
More informationDigital Mass Flow Meters and Controllers for Gases
Digital Mass Flow Meters and Controllers for Gases A Bronkhorst company. M+W Instruments. Your specialists for inline measurement WORTH KNOWING M+W Instruments was founded in 1988 and has always specialised
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationThe affordable consumption counter for compressed air and gases R 3 /4 (DN 20)
VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationBattery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information attery Powered hermal Mass Flow Meters for Gases icenta Controls Ltd, Unit 3 he Woodford Centre, Lysander Way, Old arum Park, alisbury, P4 6U, U Digital advantage:
More informationBrooks TMF-Zone 1 Models 5816-Ex/5864-Ex
Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationINSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range
INSTRUCTION MANUAL process TM Ultrasonic Flowmeter Range process TM CONTENTS Page No 1 General 4 2 Order Codes 4 3 Installation 5 & 6 4 Specifications 7 & 8 1 General 3 Installation The Process Atrato
More informationModel 601CV. Mass Flow Controller. Product Features:
Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass
More informationDescription Pressure range Connection thread Device Page
Pressure Regulator Pressure range onnection thread Device Page max. 22 l/min miniature -850 0 mbar 1 8 NPT V800.02 max. 22 l/min miniature -850 0 mbar 10-32 and flange V900.02 max. 0 l/min precise -1 +0,.4
More informationOperating Instructions DB41
PKP Process Instruments Inc. 10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax:
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationSeries 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version
Series 44 Self-operated Pressure Regulators Type 44-1 B Pressure Reducing Valve Type 44-6 B Excess Pressure Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationThermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption
Thermal flow sensor TA Di for measuring mass flow, standard flow rate and air / gas consumption Sensor TA Di 16 41.8 ZG1b and TADi 16 41.8 ZG1b/M-Bus U10a/U10M Sensor TA Di 8 ZG3b and TA Di 8 ZG3b/M-Bus
More informationAFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features
ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationHydroCOM: High energy savings and excellent controllability
HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationCORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES
SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering
More informationOperating instructions for variable area flow meter with needle valve. Model: UVR/UTR
Operating instructions for variable area flow meter with needle valve Model: UVR/UTR 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument inspection... 3 4. Regulation use... 3 5. Operating principle...
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type can be combined with... Direct flow measurement with CMOSens - Technology for nominal flow rates from 20 ml N /min to 80 l N /min (N 2 ) High accuracy and reproducibility
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...
More informationMASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers
MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that
More informationVolume Booster. Volume Booster Description Supply pressure Pressure range Connection Device Page max. bar bar thread
Volume ooster Supply pressure Pressure range onnection Device Page max. bar bar thread precise differential pressure also 17 0 1 / 10 and G 3 8 R50.02 differential pressure also 10 0.2 1 / 8 ¼ NPT 53.19
More informationTHE WORLD COMPETITIVENESS SCOREBOARD 2011
THE WORLD COMPETITIVENESS SCOREBOARD 2011 98.557 94.063 92.588 92.011 90.782 90.219 89.259 87.824 86.475 86.418 86.313 85.707 84.380 84.120 81.629 81.619 81.100 80.278 79.799 78.499 77.599 77.101 76.827
More informationBypass Mass Flow Controller (MFC) for gases
Bypass Mass Flow Controller (MFC) for gases Bypass MFC with Capillary technology for nominal flow rates from ml N /min to l N /min Suitable for aggressive gases Fieldbus option Type 870 can be combined
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationSCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties
Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationSeries 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version
Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure
More informationIN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases
IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in thermal Mass Flow Meters/Controllers and Electronic Pressure Controllers,
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8626 can be combined with Inline MFC for full scale rates from 25 l N /min to 1.500 l N /min; 1/4 to 3/4 High accuracy Short settling time Fieldbus option Type
More informationred-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information attery owered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized by
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure measuring monitoring analysing Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material:
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure measuring monitoring analysing Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material:
More informationThermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.
Thermal flow sensor TA Di for measuring mass flow, standard flow rate and air or gas consumption Drawing 4b Cable connection Sensor TA Di 8 Drawing 2b Cable connection Sensor TA Di 16... 41.8 Examples
More informationPrecision Mass Flow Meters / Controllers for Liquids and Gases
CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationanalytical bulk flow distance FLOW level pressure temperature industrial communication
analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two
More informationMeasurement of Low GAS & Liquid Flows
Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationQuick Installation Guide Doc nr.: C Date:
Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationSelf-operated Pressure Regulators Type 2405 Pressure Reducing Valve
Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve ANSI version Application Pressure reducing valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2 1) (DN
More informationButterfly Control Valve. DMK/6 Series
Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationWITT-GASETECHNIK GMBH & CO KG
WITT-GASETECHNIK GMBH & CO KG GAS MIXERS KM 20/30/60/100-2 KM 20/30/60/100-3 KM 20-2 KM 20-3 Gas mixing systems for 2 or 3 defined gases, designed for a variety of industrial applications for example,
More informationT 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version
T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version Application Excess pressure valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2
More informationUnique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.
Unique mounting features for Thermal Mass Flow Meters By Martin Raab in cooperation with CaTeC b.v. Development and production of sensors and transmitters for: humidity dew point CO2 O2 air velocity mass
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationATM/GR. Electronic pressure switches CUSTOMER BENEFITS
Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment
More informationGlass tube flowmeters Series 2000
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No
More informationSelf-operated Pressure Regulators Type 2405 Pressure Reducing Valve
Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve Application Pressure reducing valve for set points from 5 mbar to 10 bar Nominal size DN 15 to 50 Nominal pressure PN 16 to 40 Suitable
More informationbetter measurement Simply a question of
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology
More informationProgrammable Submersible Level Transmitters
Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as
More informationSeries 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve
Series Self-operated Pressure Regulators Type -6 B Excess Pressure Valve Application Set points from 0.2 to 20 bar with valves G ½, G ¾, and G as well as DN, DN 2, DN 0, and DN 0 Nominal pressure PN 2
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationVortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing
Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual
More informationCOMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid
Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationTechnical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description
Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great
More informationFirearms & parts firearms & parts firearms & parts rocket launcher components
Table 3 Exports of Military Goods by Component Categories Export Period 01 January to 31 December 1997 Destination ECL Andorra 2001 5 434 2 058 Firearms & parts Argentina 2001 54 498 468 firearms & parts
More informationBULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.
BULLETIN E485A Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change
More informationApplications. What moves your world
Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves
More informationInstruction Manual SB02, SB03, SB04 All metal flow limiter
Instruction Manual SB02, SB03, SB04 All metal flow limiter PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden-Nordenstadt Tel.: ++49-(0)6122-7055-0 Fax: ++49-(0)6122-7055-50 Email: info@pkp.de
More information2/2-Way Proportional Valve (motor-driven)
2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice
More informationPressure reducing valves Series DRV/DRVM - DRVN/DRVMN
Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN Main features Pressure reducing valves serve to reduce the pressure of the fluid downstream and to keep it at a constant level by varying its pressure
More informationPneumatic turret stop with 6, 8 and 12 stop positions for automation
SOMATEC Sondermaschinen-Vorrichtungen Komponenten für Maschinenbau Klaus Mayer Gewerbestraße 19 88636 Illmensee Telefon 07558/1441 www.somatec-mb.de Telefax 07558/674n Pneumatic turret stop with 6, 8 and
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More information800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers
800 Series Mass Flow Meters and Controllers High Performance Mass Flow Meters and Controllers WHY MASS FLOW? In most processes it is mass, not volume, which is the critical variable. Volumetric flow measurements
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationWATER PRESSURE REDUCER (SBD)
WATER PRESSURE REDUCER (SBD) December 2016 PRODUCTS Product Code Connection Size Range of Products Max. Input Pressure Pressure Setting Range 340308 1/4" SBD 340315 1/2" SBD 340415 1/2" with sleeve coupling
More informationSCH. Mechanical Pressure Switches. for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure measuring monitoring analysing SCH P3 OO Switching range: -1... + 0.1 bar - 250... +100 mbar, 1... 16 mbar a 16...
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationWater Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine
The Leading Water Flow Regulator Worldwide Essential Equipment For every injection and blow molding machine Why You Should Use Wittmann Water Flow Regulators: Instant indication of blocked mold cooling
More informationDrum-Type Gas Meters Series TG (Wet-Test)
Drum-Type Gas Meters Series TG (Wet-Test) Precision Volumetric Gas Meters for Scientific Laboratories User Benefits Highest accuracy: ±0.5% across full flow rate range Calibration traceable to German National
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More information