AutoPump Catalog. Complete Systems. Featuring the AP4 + Series and the new low - maintenance AP4 Ultra

Size: px
Start display at page:

Download "AutoPump Catalog. Complete Systems. Featuring the AP4 + Series and the new low - maintenance AP4 Ultra"

Transcription

1 AutoPump Catalog The Original Automatic Air-Powered Pumps now including the new low maintenance AP Ultra Top Choice at Remediation and Landfill Sites Around the World Complete Systems Featuring the AP + Series and the new low - maintenance AP Ultra

2 AutoPump AutoPump Automatic Air-Powered Pumps Automatic air-powered pumps offer exceptional capabilities in the severe pumping conditions found at many landfill and remediation sites. QED s AutoPump (patent pending) pumps originated the automatic air-powered pump concept in 9 and have lead the industry ever since. AutoPumps were designed specifically to handle difficult conditions reliably and safely, including hydrocarbons, landfill lechates and condensates, solvents, suspended solids, silts, corrosives, and high viscosities, along with high temperatures and frequent starts and stops. Air-powered AutoPumps are proven worldwide at thousands of sites, which is why AutoPumps are the No. choice of professionals based on reliability, durability, performance range, and technical support. The superiority of the AutoPump design is based on four key strengths: high clearance fluid pathways using air as the motive force materials of construction matched to site conditions a simple yet rugged operating mechanism Unlike electric pumps, air-powered AutoPumps use no high-speed motors, bearings or impellers, so AutoPumps don t heat up, sieze up, or get ground up. Liquid shearing is typical of electric pumps, creating oil-water emulsions that reduce the performance of downstream treatment equipment. AutoPumps cause far less liquid shearing than electric submersible pumps so downstream treatment systems can perform better. Air-powered also means eliminating the dangers and costs of electricity at and in the well. Finally, AutoPumps actually have a built-in control system they pump when there is liquid present and shut down when the level is drawn down, without the need for any sensors in the well or controls at the surface. Application Excellence Remediation applications and landfill fluids pumping are very challenging. QED is dedicated to providing a comprehensive approach to meeting the specific needs of each site and well, taking into account many factors beyond just flow rate and depth, such as: Preferred inlet position number top or bottom Pump length to match water column and meet drawdown requirements A broad range of materials of construction to match fluid properties and temperature Jacketed tubing sets, bundled hose and quick-connect options to ease installation and service A wide variety of standard and custom wellhead completions to fit site needs Experience and Expertise The AutoPump specialists at QED have unsurpassed experience in both typical and special applications, providing the quality and care that makes a difference. Call us at --- for prompt, professional assistance, or visit our web site at to access product and application information.

3 AutoPump Complete Table of Contents Systems How AutoPumps Work Why AutoPumps Are Better Guide to AutoPumps Selection Complete Systems Long AP Ultra Bottom Inlet Pump Short AP Ultra Bottom Inlet Pump Long AP Ultra Top Inlet Pump Short AP Ultra Top Inlet Pump Long AP+ Bottom Inlet Pump Short AP+ Bottom Inlet Pump Low-Drawdown AP+ Bottom Inlet Pump Long AP+ Top Inlet Pump Short AP+ Top Inlet Pump Low-Drawdown AP+ Top Inlet Pump Long AP Bottom Inlet Pump Short AP Bottom Inlet Pump Long AP Top Inlet Pump Short AP Top Inlet Pump Long AP Bottom Inlet Pump Short AP Bottom Inlet Pump Long AP Top Inlet Pump Short AP Top Inlet Pump Tubing and Hose Well Caps Flow Counters Air Supply Tank-Full Shutoff Application Data Sheet Warranty Inside Back Cover 55 Bishop Circle West Dexter, MI USA... T: 7: F: info@qedenv.com 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

4 AutoPump How AutoPumps Work Fill Cycle Discharge Cycle The fluid pushes the inlet check valve open and fluid enters the pump. As the fluid level rises, air is expelled through the exhaust air valve and the internal float rises to the top of its stroke. With the air inlet open, air pressure builds up within the pump body. This causes the fluid inlet check valve to close and forces the fluid to be displaced up and out of the fluid outlet. As the fluid level falls, the float moves downward to the bottom of its stroke. In this upper position, the float triggers a lever assembly, which closes the air exhaust valve and opens the air inlet allowing air to enter and pressurize the pump. In this lower position, the float triggers the lever assembly to close the air supply and open the air exhaust valve, and a new cycle begins. Note: This illustration is for a bottom filling format. A top loader is also available with both the inlet and discharge at the top of the pump. AutoPump Reliability The AutoPump air-powered pump operating cycle diagrams and explanation above tell just part of the story of AutoPump technology. Engineering an automatic pump to function in clear water is just the start. The real secrets of AutoPump durability and reliability are based on over years of site experience in difficult pumping applications. AutoPumps are designed to resist chemical attack, abrasive wear, mechanical wear, solids deposits, viscous fluids and elevated temperatures. The entire air valve control mechanism has been refined in many subtle ways to survive these severe pumping conditions, using special materials, tolerances, and safety factors to provide years of trouble-free cycling. And, now there is the new AutoPump AP Ultra, which uses proprietary non-stick finishes on the float and discharge tube to help reduce solid buildups, extending the time between cleaning and making it much faster and easier to clean the pump. AutoPumps are the first of their tolerances, and safety factors to provide years of trouble-free cycling. AutoPumps are the first of their kind, first in design experience, and first in reliability and durability.

5 AutoPump Why AutoPumps Are Better QED-developed unique Easy Fittings TM Quick Release Connectors For quick disconnect/reconnect without the need to shorten pump tubing or remove/replace tubing clamps. QED originated the concept of jacketed tubing to make pump installation/removal easier. AutoPump AP+ The same time-proven, reliable, air valve assembly that has made the AP+ the industry s preferred choice since 9. Superior body. Light weight, won t corrode, won t dent. Air efficiency saves up to $/year in energy costs compared to other pneumatic pumps. Superior materials choice. Most of the AutoPump s internal components are available in a variety of materials to fit site specific conditions. Same standard 5-year warranty. No other pneumatic pump manufacturer even comes close. Superior float. Easily removable float retainer. Maximum flow rate over gpm. Inlet check plug design durability has been proven at thousands of sites in over countries. Easy pump disassembly. Removing four bolts allows removal of the pump casing. Easy O-ring fit due to precision tolerance casing ID. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

6 AutoPump Guide to AutoPump Selection Quick Guide to AutoPump Selection An important advantage of an AutoPump (patent pending) air-powered Pump system is the wide range of choices to truly match site needs. Below is a quick guide to the major configurations and options offered in the AutoPump line, to help you determine which models are best for your project. Of course, you can just call us at ---, or us at info@qedenv.com, for fast, personal service by our application specialists. As a general guideline, pump model selection is usually based on the following primary application criteria.they are presented in the common sequence of consideration, but special site needs may alter the priority. Maximum Flow and Depth pump model, depth, submergence, and drive pressure determine the maximum flow rate that can be achieved; see specific pump curves for detailed flow information Pump Diameter to fit the well ID; also, larger diameter pumps deliver higher flow rates, all other factors being equal Inlet Position top or bottom inlet; a top inlet enhances removal of LNAPLs, while bottom inlets provide the highest flow rates and greatest solids-handling capacity for DNAPL, and landfill fluids Actuation Level minimum height of liquid needed to actuate the pump, also equal to the minimum drawdown level; low-drawdown models are optimized for maximum drawdown Materials of Construction many models are available in upgraded materials for special applications, such as extremes of ph, suspended solids, high temperatures, and aggressive solvents. The new low-maintenance AutoPump AP Ultra uses special non-stick finishes on the float and discharge tube. All metallic parts are -grade stainless steel, allowing for greater corrosion resistance. AutoPumps Model Pg# Inlet Out. Diameter Overall Length Max. Flow Max. Depth Act. Level Position in./cm in./cm gpm/lpm ft./cm in./cm Bottom Inlet AP Pumps Long AP Ultra Bottom Inlet Long AP.B 7 Short AP Ultra Bottom Inlet Short AP.B Long AP + Bottom Inllet Long AP + B Short AP + Bottom Inlet Short AP + B Low-Drawdown AP + Bottom Inlet LD AP + B Bottom. / / / 5 / 7. / 9 Bottom. / / / 9 5 /.7 / Bottom. / / / 5 / 7. / 9 Bottom. / / / 9 5 / 7.7 / Bottom. / / 7 7 /.5 5 / 7 5. / 9 Top Inlet AP Pumps Long AP Ultra Top Inlet Long AP.T Short AP Ultra Top Inlet Short AP.T Long + Top Inlet Long AP + T Short AP+ Top Inlet Short AP+ T Low-Drawdown AP+ Top Inlet LD AP+T Bottom Inlet AP Pumps Long AP Bottom Inlet Long APB Short AP-Bottom Inlet Short APB 5 Top Inlet AP Pumps Long AP-Top Inlet Long APT 5 Short AP Top Inlet Short APT 5 Bottom Inlet AP Pumps Long AP Bottom Inlet Long APB Short AP Bottom Inlet Short APB Top Inlet AP Pumps Long AP-Top Inlet Long APT 7 Short AP-Top Inlet Short APT 7 Top. / / / 5 / 7. / 5 Top. / 9. 5 / 9 / 5 / 7. / Top. / / / 5 / 7. / 5 Top. / 9. 5 / 9 / 5 / 7. / Top. / / 7. / 5 / 7 7. / 7 Bottom. /. 5 / 7. / / 7 / 79 Bottom. /. / 7 /.7 75 /. / 5 Top. /. 57 / 5 5. / / 7 / 5 Top. /. 7 / 9. /. 75 /. / 7 Bottom.75 /.5 55 / 9. /. / 9. 5 / 9 Bottom.75 /.5 / 5 / 7.57 / 9. / 5 Top.75 /.5 57 /.9 / 7. / 9. 5 / Top.75 /.5 5 / 9. /. / 9. / 7 Consult QED for higher flow requirements High Pressure Option for AP pumps Optional. (.cm) OD available

7 AutoPump Complete Systems Complete AutoPump systems offer the greatest assurance of a smooth installation, dependable performance and easy maintenance. Common system components include: In-well hose and tubing see page 7 Wellhead completion caps and flanges see page 79 Cycle counters see page Air system filter/regulators see page Call --- or visit for prompt assistance with all of the above. Basic Pump Systems Basic System Bottom Inlet Pump Basic System Top Inlet Pump Air Supply From Compressor Cycle Counter Fluid Discharge Barb Fittings AP Bottom Inlet Water Note: Support Harness and rope omitted for clarity 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

8 AP.B AutoPump AP Ultra Bottom Inlet, Long Max. Flow O.D. Length gpm ( lpm)*. in. (9. cm) 5. in. ( cm) Description The AutoPump AP Ultra Bottom Inlet Long provides maximum capabilities and flow in a bottom inlet pump for ( mm) diameter and larger wells. The base model delivers flow rates up to gpm ( lpm)*. The AP Ultra uses proprietary non-stick finishes on the float and discharge tube to reduce solids buildup, extending the time between cleaning and making it much faster and easier to clean the pump. All metallic parts are -grade Stainless Steel, which has greater corrosion resistance and can withstand attacks of the harshest leachate. The AP. Bottom Inlet Long pump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over years.. Proprietary finishes extend the time between cleaning. The AutoPump Heritage The AutoPump AP Ultra Bottom Inlet Long is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. All metallic parts are -grade SS for better corrosion resistance.. New and improved valve stem connections have no fasteners, or cotter pins. Exhaust seat is easy to adjust. 5. Five-year warranty. *Consult QED for higher flow requirements

9 AutoPump AP Ultra Bottom Inlet, Long AP.B Pump Dimensions Specifications & Operating Requirements Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage " - Long AP Ultra Bottom Inlet Bottom. in. (9. cm) 5. in. ( cm) lbs. (7. kg) gpm ( lpm) - See Flow Rate Chart* gal (. -.L ). in. (9 cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).-. scf / gal. (.-.5 liters of air / fluid liter) - See Air Usage Chart Length 5. ( cm) Actuation Level." (9 cm) High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Stainless Steel Barbs or Quick Connects or Easy Fittings Inlet O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (Base model) AutoPump AP Ultra pumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED about AP upgrades. AutoPump AP Ultra Long and Short pumps are warranted for five (5) years: % materials and workmanship. *Consult QED for higher flow requirements 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

10 AP.B AutoPump AP Ultra Bottom Inlet, Long Flow Rates /-INCH /-INCH /-INCH / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD FT PSI 7 PSI Kg/cm 5 Kg/cm FT PSI Kg/cm PSI 7 Kg/cm 7 PSI 5 Kg/cm PSI 7 Kg/cm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT mm 9 mm 9 mm inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD INCH. PSI.7 5. mm 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH. PSI.7 5. mm 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD -INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

11 AutoPump AP Ultra Bottom Inlet, Long AP.B Air Consumption / inch (9 mm) (Equivalent to -Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL)...9. PSI 7 Kg/cm 7 PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5. mm) (Equivalent to.5-inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm PSI 7 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

12 AP.B AutoPump AP Ultra Bottom Inlet, Short Max. Flow O.D. Length gpm (9 lpm). in. (9. cm) 9. in. ( cm) Description The AutoPump AP Ultra Bottom Inlet Short provides maximum capabilities and flow in a bottom inlet pump for ( mm) diameter and larger wells with shorter water columns and/or the need to pump down to lower water levels, compared to full-length pumps, and it can deliver flow rates up to gpm (9 lpm)*. The AP Ultra uses proprietary non-stick finishes on the float and discharge tube to reduce solids buildup, extending the time between cleaning and making it much faster and easier to clean the pump. All metallic parts are -grade Stainless Steel, which has greater corrosion resistance and can withstand attacks of the harshest leachate. The AP. Bottom Inlet Short pump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over years.. Proprietary finishes extend the time between cleaning.. All metallic parts are -grade SS for better corrosion resistance. The AutoPump Heritage The AutoPump AP Ultra Bottom Inlet Short is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. New and improved valve stem connections have no fasteners, or cotter pins. Exhaust seat is easy to adjust. 5. Five-year warranty. *Consult QED for higher flow requirements

13 AutoPump AP Ultra Bottom Inlet, Short AP.B Pump Dimensions Specifications & Operating Requirements Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage " - Short AP Ultra Bottom Inlet Bottom. in. (9. cm) 9. in. ( cm) lbs. (5.9 kg) gpm (9 lpm)* - See Flow Rate Chart. -. gal (. -.L ).7 in. ( cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).-.5 scf / gal. ( liters of air / fluid liter) - See Air Usage Chart Length 9." ( cm) Actuation Level.7" ( cm) High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Stainless Steel Barbs or Quick Connects or Easy Fittings Inlet O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (Base model) AutoPump AP Ultra pumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED about AP upgrades. AutoPump AP Ultra Long and Short pumps are warranted for five (5) years: % materials and workmanship. *Consult QED for higher flow requirements 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

14 AP.B AutoPump AP Ultra Bottom Inlet, Short Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT. FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT. FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT inch (5. mm) (Equivilant to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD INCH mm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH PSI 7 Kg/cm mm PSI Kg/cm 7 PSI 5 Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

15 AutoPump AP Ultra Bottom Inlet, Short AP.B Air Consumption..5. PSI 7 Kg/cm..5 / inch (9 mm) (Equivalent to -Inch O.D. Tubing).. 7 PSI 5 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)...7 PSI Kg/cm FT PSI 7 Kg/cm..5 inch (5. mm) (Equivalent to.5-inch O.D. Tubing) PSI 5 Kg/cm 9. CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com

16 AP.T Top Inlet, Long AutoPump AP Ultra Max. Flow O.D. Length gpm ( lpm). in. (9. cm) 5.7 in. ( cm) Description The AutoPump AP Ultra Top Inlet Long provides maximum capabilities and flow in a top inlet pump for diameter and larger wells needing an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs, and it can deliver flow rates up to gpm ( lpm)*. The AP Ultra uses proprietary non-stick finishes on the float and discharge tube to reduce solids buildup, extending the time between cleaning and making it much faster and easier to clean the pump. All metallic parts are -grade Stainless Steel, which has greater corrosion resistance and can withstand attacks of the harshest leachate. The AP. Top Inlet Long pump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over years.. Proprietary finishes extend the time between cleaning.. All metallic parts are -grade SS for better corrosion resistance. The AutoPump Heritage The AutoPump AP Ultra Top Inlet Long is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. New and improved valve stem connections have no fasteners, or cotter pins. Exhaust seat is easy to adjust. 5. Five-year warranty. *Consult QED for higher flow requirements

17 AutoPump AP Ultra Top Inlet, Long AP.T Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 5.7" ( cm) Actuation Level." (5 cm) Liquid Discharge Inlet Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type " - Long AP Ultra Top Inlet Top. in. (9. cm) 5.7 in. ( cm) lbs. (.7 kg) gpm ( lpm) - See Flow Rate Chart gal (. -.L ). in. (5 cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).5-. scf / gal. (.-. liters of air / fluid liter) 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal Stainless Steel, Viton, Acetal, PVDF Stainless Steel Barbs or Quick Connects or Easy Fittings Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID O.D.." (9. cm) Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Standard Application Limits (standard model) AutoPump AP Ultra pumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED. AutoPump AP Ultra Long and Short pumps are warranted for five (5) years: % materials and workmanship. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

18 AP.T Top Inlet, Long AutoPump AP Ultra Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. -INCH inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD. PSI 7 Kg/cm.7 PSI 7 PSI 5 Kg/cm Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD mm /-INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm -INCH PSI 7 Kg/cm.7 5. mm 7 PSI PSI 5 Kg/cm Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm -INCH FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI. 7 Kg/cm.7 5. mm 7 PSI PSI Kg/cm 5 Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

19 AutoPump AP Ultra Top Inlet, Long AP.T Air Consumption / inch (9 mm) (Equivalent to -Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL)...9 PSI 7 Kg/cm 7 PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5. mm) (Equivalent to.5-inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm PSI 7 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

20 AP.T Top Inlet, Short AutoPump AP Ultra Max. Flow O.D. Length 9 gpm ( lpm). in. (9. cm) 5 in. ( cm) Description The AutoPump AP Ultra Top Inlet Short provides maximum capabilities and flow in a top inlet pump for ( mm) diameter and larger wells with shorter water columns and the need for an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs, and it can deliver flow rates up to 9 gpm ( lpm)*. The AP Ultra uses proprietary non-stick finishes on the float and discharge tube to reduce solids buildup, extending the time between cleaning and making it much faster and easier to clean the pump. All metallic parts are -grade Stainless Steel, which has greater corrosion resistance and can withstand attacks of the harshest leachate. The AP. Top Inlet Short pump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over years.. Proprietary finishes extend the time between cleaning.. All metallic parts are -grade SS for better corrosion resistance. The AutoPump Heritage The AutoPump AP Ultra Top Inlet Short is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. New and improved valve stem connections have no fasteners, or cotter pins. Exhaust seat is easy to adjust. 5. Five-year warranty. *Consult QED for higher flow requirements

21 AutoPump AP Ultra Top Inlet, Short AP.T Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 5" ( cm) Actuation Level." ( cm) Liquid Discharge Inlet Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type " - Short AP Ultra Top Inlet Top. in. (9. cm) 5 in. ( cm) 7 lbs. (7. kg) 9 gpm ( lpm) - See Flow Rate Chart. -. gal (. -.L ). in. ( cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).5-.5 scf / gal. (.-. liters of air / fluid liter) - See Air Usage Chart 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, Acetal, PVDF Stainless Steel Barbs or Quick Connects or Easy Fittings O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Standard Application Limits (standard model) AutoPump AP Ultra pumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED. AutoPump AP Ultra Long and Short pumps are warranted for five (5) years: % materials and workmanship. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

22 AP.T Top Inlet, Short AutoPump AP Ultra Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD...5-INCH O.D. TUBING PSI 7 Kg/cm.7.75 mm O.D. TUBING PSI Kg/cm 7 PSI 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. /-INCH PSI 7 Kg/cm mm.5-inch O.D. TUBING PSI 7 Kg/cm mm O.D. TUBING /-INCH PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm.5-inch O.D. TUBING PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD. PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT..75 mm O.D. TUBING FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

23 AutoPump AP Ultra Top Inlet, Short AP.T Air Consumption..5. PSI 7 Kg/cm..5 / inch (9 mm) (Equivalent to -Inch O.D. Tubing).. 7 PSI 5 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT...5. PSI 7 Kg/cm..5 inch (5. mm) (Equivalent to.5-inch O.D. Tubing) PSI 5 Kg/cm 9. CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

24 AP + B AutoPump Bottom Inlet, Long Max. Flow O.D. Length gpm ( lpm)*. in. (9. cm) 5. in. ( cm) Description The AP + Bottom Inlet Long AutoPump provides maximum capabilities and flow in a bottom inlet pump for ( mm) diameter and larger wells. The base model delivers flow rates up to gpm ( lpm)*, and optional versions are offered to handle even the most severe remediation and landfill pumping applications. The AP+ Long Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, noobligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years The AutoPump Heritage The AP + Bottom Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. The highest flow rates and deepest pumping capabilities in the industry. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, hydrocarbons corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. Five-year warranty *Consult QED for higher flow requirements

25 AutoPump Bottom Inlet, Long AP+B Pump Dimensions Specifications & Operating Requirements Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage " - Long AP+ Bottom Inlet Bottom. in. (9. cm) 5. in. ( cm) lbs. (7. kg) gpm ( lpm) - See Flow Rate Chart* gal (. -.L ). in. (9 cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).-. scf / gal. (.-.5 liters of air / fluid liter) - See Air Usage Chart Length 5. ( cm) Actuation Level." (9 cm) High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Inlet O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (Base model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED about AP upgrades. Long and Short AP+ AutoPumps are warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids *Consult QED for higher flow requirements 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

26 AP+B AutoPump Bottom Inlet, Long Flow Rates /-INCH /-INCH /-INCH / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD FT PSI 7 PSI Kg/cm 5 Kg/cm FT PSI Kg/cm PSI 7 Kg/cm 7 PSI 5 Kg/cm PSI 7 Kg/cm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT mm 9 mm 9 mm inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD INCH. PSI.7 5. mm 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH. PSI.7 5. mm 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD -INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

27 AutoPump Bottom Inlet, Long AP+B Air Consumption / inch (9 mm) (Equivalent to -Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL)...9. PSI 7 Kg/cm 7 PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5. mm) (Equivalent to.5-inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm PSI 7 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

28 AP+B AutoPump Bottom Inlet, Short Max. Flow O.D. Length gpm (9 lpm). in. (9. cm) 9. in. ( cm) Description The AP + Bottom Inlet Short AutoPump provides maximum capabilities and flow in a bottom inlet pump for ( mm) diameter and larger wells with shorter water columns and/or the need to pump down to lower water levels, compared to full-length pumps. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to gpm (9 lpm)*. The AP+ Short Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet sitespecific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The highest flow rates and deepest pumping capabilities in the industry The AutoPump Heritage The AP + Bottom Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, hydrocarbons corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. Five-year warranty *Consult QED for higher flow requirements

29 AutoPump Bottom Inlet, Short AP+B Pump Dimensions Specifications & Operating Requirements Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage " - Short AP+ Bottom Inlet Bottom. in. (9. cm) 9. in. ( cm) lbs. (5.9 kg) gpm (9 lpm)* - See Flow Rate Chart. -. gal (. -.L ).7 in. ( cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).-.5 scf / gal. ( liters of air / fluid liter) - See Air Usage Chart Length 9." ( cm) Actuation Level.7" ( cm) High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Inlet O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (Base model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED about AP upgrades. Long and Short AP+ AutoPumps are warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids *Consult QED for higher flow requirements 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

30 AP+B AutoPump Bottom Inlet, Short Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT. FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT. FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT inch (5. mm) (Equivilant to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD INCH mm PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH PSI 7 Kg/cm mm PSI Kg/cm 7 PSI 5 Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

31 AutoPump Bottom Inlet, Short AP+B Air Consumption..5. PSI 7 Kg/cm..5 / inch (9 mm) (Equivalent to -Inch O.D. Tubing).. 7 PSI 5 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)...7 PSI Kg/cm FT PSI 7 Kg/cm..5 inch (5. mm) (Equivalent to.5-inch O.D. Tubing) PSI 5 Kg/cm 9. CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

32 LDAP+B AutoPump Low-Drawdown, Bottom Inlet Max. Flow O.D. Length 7. gpm (.5 lpm). in. (9. cm) 7.5 in. (7 cm) Description The AP+ Low-Drawdown Bottom Inlet AutoPump provides maximum capabilities and flow in a bottom inlet pump for ( mm) diameter and larger wells with very short water columns and/or the need to pump down to as low as 5. (9 cm) above the bottom. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to 7 gpm (.5 lpm). The AP+ Low Drawdown Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The highest flow rates and deepest pumping capabilities in the industry in a low drawdown bottom-fill pump The AutoPump Heritage The AP+ Low-Drawdown Bottom Inlet AutoPump is part of the famous AutoPump family of original automatic airpowered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, hydrocarbons corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. One-year warranty

33 AutoPump Low-Drawdown, Bottom Inlet LDAP+B Pump Dimensions Specifications & Operating Requirements Length 7.5 (7 cm) Actuation Level 5." (9 cm) Liquid Discharge Air Supply Exhaust Inlet O.D.." (9. cm) Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Low-Drawdown AP+ Bottom Inlet Bottom ( standard plug type check valve). in. (9. cm) 7.5 in. (7 cm) lbs. (5. kg) 7 gpm (.5 lpm). -. gal (. -.L) 5 ft. (7 m) 5 - psi (. -. kg/cm) 5. in. (9 cm). -. scf/gal (. -.5 liters of air/fluid liter) See Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (Base model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED about AP upgrades. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: F ( C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

34 LDAP+B AutoPump Low-Drawdown, Bottom Inlet Flow Rates -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT. ( cm) SUBMERGENCE OF PUMP HEAD 9 7 /-INCH 5 PSI 7 Kg/cm PSI Kg/cm 7 PSI 5 Kg/cm /-INCH / inch (9 mm) (Equivalent to -Inch O.D. Tubing) FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI Kg/cm 7 PSI 5 Kg/cm PSI 7 Kg/cm FT FT FT.. 9 mm 9 mm 9 mm inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD INCH PSI 7 Kg/cm. 5. mm PSI Kg/cm 7 PSI 5 Kg/cm. FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH PSI 7 Kg/cm. 5. mm PSI Kg/cm 7 PSI 5 Kg/cm. FT FT. ( cm) SUBMERGENCE OF PUMP HEAD INCH PSI 7 Kg/cm. 5. mm PSI Kg/cm 7 PSI 5 Kg/cm FT. 5.9 FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

35 AutoPump Low-Drawdown, Bottom Inlet LDAP+B Air Consumption CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm PSI Kg/cm..5. PSI 7 Kg/cm FT. / inch (9 mm) (Equivalent to -Inch O.D. Tubing) LITER OF AIR LITER PUMPED (STD L/LITER) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL).9..7 PSI. 7 Kg/cm PSI. 5 Kg/cm PSI. Kg/cm inch (5. mm) (Equivalent to.5-inch O.D. Tubing) LITER OF AIR.7 LITER PUMPED. (STD L/LITER) FT Bishop Circle West Dexter, MI USA... F info@qedenv.com

36 AP+T Top Inlet, Long AutoPump Max. Flow O.D. Length gpm ( lpm). in. (9. cm) 5.7 in. ( cm) Description The AP + Top Inlet Long AutoPump provides maximum capabilities and flow in a top inlet pump for diameter and larger wells needing an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to gpm*. The AP+ Long Top Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, noobligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The highest flow rates and deepest pumping capabilities in the industry The AutoPump Heritage The AP + Top Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, hydrocarbons corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. Five-year warranty *Consult QED for higher flow requirements

37 AutoPump Top Inlet, Long AP+T Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 5.7" ( cm) Actuation Level." (5 cm) Liquid Discharge Inlet Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type " - Long AP+ Top Inlet Top. in. (9. cm) 5.7 in. ( cm) lbs. (.7 kg) gpm ( lpm) - See Flow Rate Chart gal (. -.L ). in. (5 cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).5-. scf / gal. (.-. liters of air / fluid liter) 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal Stainless Steel, Viton, Acetal, PVDF Brass or Stainless Steel Barbs or Quick Connects Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID O.D.." (9. cm) Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Standard Application Limits (standard model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED. Long and Short AP+ AutoPumps are warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

38 AP+T Top Inlet, Long AutoPump Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. -INCH inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD. PSI 7 Kg/cm.7 PSI 7 PSI 5 Kg/cm Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD mm /-INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm -INCH PSI 7 Kg/cm.7 5. mm 7 PSI PSI 5 Kg/cm Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm -INCH FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI. 7 Kg/cm.7 5. mm 7 PSI PSI Kg/cm 5 Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

39 AutoPump Top Inlet, Long AP+T Air Consumption / inch (9 mm) (Equivalent to -Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL)...9 PSI 7 Kg/cm 7 PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5. mm) (Equivalent to.5-inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm PSI 7 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

40 AP+T Top Inlet, Short AutoPump Max. Flow O.D. Length 9 gpm ( lpm). in. (9. cm) 5 in. ( cm) Description The AP + Top Inlet Short AutoPump provides maximum capabilities and flow in a top inlet pump for ( mm) diameter and larger wells with shorter water columns and the need for an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to 9 gpm ( lpm)*. The AP+ Short Top Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, noobligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The highest flow rates and deepest pumping capabilities in the industry The AutoPump Heritage The AP + Top Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as hydrocarbons, solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/ stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, wellhead caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, hydrocarbons corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. Five-year warranty *Consult QED for higher flow requirements

41 AutoPump Top Inlet, Short AP+T Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 5" ( cm) Actuation Level." ( cm) Liquid Discharge Inlet Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Min. Actuation Level Standard Pump Max. Depth Air Pressure Range Air Usage High Pressure Pump Max. Depth Air Pressure Range Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type " - Short AP+ Top Inlet Top. in. (9. cm) 5 in. ( cm) 7 lbs. (7. kg) 9 gpm ( lpm) - See Flow Rate Chart. -. gal (. -.L ). in. ( cm) 5 ft. (7 m) 5 - psi (. -. kg/cm).5-.5 scf / gal. (.-. liters of air / fluid liter) - See Air Usage Chart 5 ft. ( m) 5 - psi (. -. kg/cm).7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal Stainless Steel, Viton, Acetal, PVDF Brass or Stainless Steel Barbs or Quick Connects O.D.." (9. cm) Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Standard Application Limits (standard model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED. Long and Short AP+ AutoPumps are warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

42 AP+T Top Inlet, Short AutoPump Flow Rates / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH..7 9 mm PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD...5-INCH O.D. TUBING PSI 7 Kg/cm.7.75 mm O.D. TUBING PSI Kg/cm 7 PSI 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. /-INCH PSI 7 Kg/cm mm.5-inch O.D. TUBING PSI 7 Kg/cm mm O.D. TUBING /-INCH PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD.. PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT mm.5-inch O.D. TUBING PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD. PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT..75 mm O.D. TUBING FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

43 AutoPump Top Inlet, Short AP+T Air Consumption..5. PSI 7 Kg/cm..5 / inch (9 mm) (Equivalent to -Inch O.D. Tubing).. 7 PSI 5 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT...5. PSI 7 Kg/cm..5 inch (5. mm) (Equivalent to.5-inch O.D. Tubing) PSI 5 Kg/cm 9. CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

44 LDAP+T AutoPump Low-Drawdown, Top Inlet Max. Flow O.D. Length. gpm ( lpm). in. (9. cm).75 in. (7 cm) Description The Low-Drawdown AP + Top Inlet AutoPump provides maximum capabilities and flow in a top inlet pump for ( mm) diameter and larger wells with very short water columns and/or the need to pump down to as low as ( cm) above the bottom. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to. gpm ( lpm). The Low Drawdown AP+ Top Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, noobligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The highest flow rates and deepest pumping capabilities in the industry in a low drawdown top-fill pump The AutoPump Heritage The Low-Drawdown AP + Top Inlet AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Patented, proven design for superior reliability and durability, even in severe applications. Handles solids, solvents, corrosive conditions, viscous fluids and high temperatures beyond the limits of electric pumps 5. One-year warranty

45 AutoPump Low-Drawdown, Top Inlet LDAP+T Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings.75" (7 cm) Actuation Level 7." (7 cm) Liquid Discharge Inlet Air Supply Exhaust O.D.." (9. cm) Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Low-Drawdown AP + Top Inlet Top. in. (9. cm).75 in. (7 cm) lbs. (5. kg). gpm ( lpm). -. gal (. -.L) 5 ft. (7 m) 5 - psi (. -. kg/cm) 7. in. (7 cm). -.5 scf/gal (. -.5 liters of air/ fluid liter) see Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal Stainless Steel, Viton, Acetal, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon in. (5 mm) or -/ in. ( mm) OD / in. ( mm) OD 5/ in. ( mm) OD Nitrile / in. (9 mm) or in. (5 mm) ID / in. (9.5 mm) ID / in. ( mm) ID Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Standard Application Limits (standard model) AP+ AutoPumps are designed to handle the application ranges described below. For applications outside these ranges, consult QED. Long and Short AP+ AutoPumps are warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: F ( C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

46 LDAP+T AutoPump Low-Drawdown, Top Inlet Flow Rates /-INCH /-INCH /-INCH / inch (9 mm) (Equivalent to -Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 9 mm PSI 7 PSI Kg/cm 5 Kg/cm. FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 9 mm PSI Kg/cm 7 PSI 5 Kg/cm..5.7 FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 9 mm PSI Kg/cm 7 PSI 5 Kg/cm. FT INCH -INCH -INCH inch (5. mm) (Equivalent to.5-inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 5. mm PSI Kg/cm 7 PSI 5 Kg/cm. FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 5. mm PSI Kg/cm 7 PSI 5 Kg/cm. FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm mm PSI Kg/cm 7 PSI. 5 Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

47 AutoPump Low-Drawdown, Top Inlet LDAP+T Air Consumption CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL).9.7. PSI 7 Kg/cm LITER OF AIR.7.7. LITER PUMPED.5. (STD L/LITER) 7 PSI 5 Kg/cm PSI Kg/cm FT / inch (9 mm) (Equivalent to -Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 7 Kg/cm PSI 5 Kg/cm PSI Kg/cm FT inch (5. mm) (Equivalent to.5-inch O.D. Tubing) LITER OF AIR LITER PUMPED (STD L/LITER) 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

48 APB AutoPump Bottom Inlet, Long Max. Flow O.D. Length 7. gpm ( lpm). in. (. cm) 5 in. ( cm) Description The APB Bottom Inlet Long AutoPump is designed for moderate-duty remediation pumping applications with well casings (75 mm) diameter and larger. Call QED for prompt, no-obligation assistance on your pumping project needs. The AutoPump Heritage The APB Bottom Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project. Advantages. Based on the original automatic air-powered well pump, proven worldwide over 5 years. Competitive flow rates and pumping capabilities. Patented, proven design for superior reliability and durability. Handles solids, some solvents, hydrocarbons and corrosive conditions beyond the limits of electric pumps 5. Two-year warranty

49 AutoPump Bottom Inlet, Long APB Pump Dimensions Specifications & Operating Requirements Length with Standard Screen 5" ( cm) Actuation Level " (79 cm) Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Length Overall, w / Extended Screen Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Long AP Bottom Inlet Bottom. in. (. cm) 5 in. ( cm) 57 in. (5 cm) lbs. (5. kg) 7. gpm ( lpm) - See Flow Rate Chart. -. gal (.7 -.L ) ft. (7 m) 5 - psi ( kg/cm) in. (79 cm).-.5 scf / gal. (.5-. liters of air / fluid liter) - See Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, UHMWPE, Brass Stainless Steel, Viton, Acetal, Nylon Brass or Stainless Steel Barbs or Quick Connects Nylon / in. (9 mm) or in. (5 mm) OD / in. ( mm) OD 5/ in. ( mm) OD Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. UHMWPE - Ultra High Molecular Weight Polyethylene Inlet O.D.." (. cm) extended screen adds 5" Application Limits AP AutoPumps are designed to handle the application range described below. For applications outside this range, consider the AP and AP models. AP AutoPumps are warranted for two () years: % materials and workmanship. Maximum Temperature: F (9 C) ph Range: -9 Some solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

50 APB AutoPump Bottom Inlet, Long Flow Rates /-INCH O.D. TUBE /-INCH O.D. TUBE -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD inch (9 mm) O.D. Fluid Discharge Tubing PSI 7 Kg/cm. PSI 7 PSI Kg/cm 5 Kg/cm FT PSI 7 Kg/cm. 9 mm O.D. TUBE PSI 7 PSI Kg/cm 5 Kg/cm FT. 9 mm O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD inch (5 mm) O.D. Fluid Discharge Tubing PSI 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT. PSI 7 Kg/cm O.D. TUBE PSI 7 PSI Kg/cm 5 Kg/cm FT. 5 mm O.D. TUBE 5 mm /-INCH O.D. TUBE FT. ( cm) SUBMERGENCE OF PUMP HEAD 9.. FT. ( cm) SUBMERGENCE OF PUMP HEAD 9 Kg/cm PSI PSI 7 Kg/cm -INCH 7 Kg/cm. 9 mm O.D. TUBE. 5 mm O.D. TUBE O.D. TUBE PSI 7 PSI PSI 7 PSI 5 Kg/cm. Kg/cm 5 Kg/cm. FT. FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

51 AutoPump Bottom Inlet, Long APB Air Consumption..5. PSI 7 Kg/cm inch (9 mm) O.D. Fluid Discharge Tubing CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5 mm) O.D. Fluid Discharge Tubing.. PSI 7 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

52 APB AutoPump Bottom Inlet, Short Max. Flow O.D. Length. gpm (.7 lpm). in. (. cm) in. (. cm) Description The AP Bottom Inlet Short AutoPump is designed for moderate-duty remediation pumping applications with well casings (75 mm) diameter and larger. It is designed for wells having shorter water columns and/or the need to pump down to lower water levels, compared to full-length pumps. Complete system components such as tubing and hose sets, well caps, and flow counters are available for the AP Long Bottom Inlet AutoPump. Call QED for prompt, noobligation assistance on your pumping project needs. Advantages. Based on the original automatic air-powered well pump, proven worldwide over 5 years The AutoPump Heritage The AP Bottom Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Competitive flow rates and pumping capabilities. Patented, proven design for superior reliability and durability. Handles solids, some solvents, hydrocarbons and corrosive conditions beyond the limits of electric pumps 5. Two-year warranty 5

53 AutoPump Bottom Inlet, Short APB Pump Dimensions Specifications & Operating Requirements Length with Standard Screen " (7 cm) Actuation Level " (55.9 cm) Liquid Discharge Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Length Overall, w / Extended Screen Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Short AP Bottom Inlet Bottom. in. (. cm) in. (7cm) 7 in. (7cm) lbs. (.5 kg). gpm (.7 lpm) - See Flow Rate Chart. -.5 gal (. -.57L ) 75 ft. (. m) 5 - psi ( kg/cm) in. (5 cm).5 -. scf / gal. (.-. liters of air / fluid liter) - See Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, UHMWPE*, Brass Stainless Steel, Viton, Acetal, Nylon Brass or Stainless Steel Barbs or Quick Connects Nylon / in. (9 mm) or in. (5 mm) OD / in. ( mm) OD 5/ in. ( mm) OD extended screen adds 5" Inlet O.D.." (. cm) Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. UHMWPE - Ultra High Molecular Weight Polyethylene Application Limits AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consider the AP and AP models. AP AutoPumps are warranted for two () years: % materials and workmanship. Maximum Temperature: F (9 C) ph Range: -9 Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

54 APB AutoPump Bottom Inlet, Short Flow Rates /-INCH O.D. TUBE /-INCH O.D. TUBE /-INCH O.D. TUBE -INCH (5 cm) PSI PSI. Kg/cm 5.7 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD mm O.D. TUBE PSI PSI. Kg/cm 5.7 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD 9.75 inch (9 mm) O.D. Fluid Discharge Tubing SUBMERGENCE OF PUMP HEAD mm O.D. TUBE PSI PSI. Kg/cm 5.7 Kg/cm FT mm O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH (5 cm) PSI. Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI PSI. Kg/cm 5.7 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD 9. inch (5 mm) O.D. Fluid Discharge Tubing SUBMERGENCE OF PUMP HEAD PSI 5.7 Kg/cm mm O.D. TUBE PSI PSI Kg/cm 5.7 Kg/cm. FT mm O.D. TUBE 5 mm O.D. TUBE FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. 5 FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

55 AutoPump Bottom Inlet, Short APB Air Consumption PSI 5.7 Kg/cm..75 inch (9 mm) O.D. Fluid Discharge Tubing CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT PSI 5.7 Kg/cm.. inch (5 mm) O.D. Fluid Discharge Tubing CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F

56 APT Top Inlet, Long AutoPump Max. Flow O.D. Optional O.D. Length 5. gpm ( lpm). in. (. cm). in. (. cm) 57 in. (5 cm) Description The APT Top Inlet Long AutoPump is designed for moderate-duty remediation pumping applications with well casings ( cm) diameter and larger using available. (. cm) inlet. It is designed for applications requiring an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. Based on the original automatic air-powered well pump, proven worldwide over 5 years The AutoPump Heritage The APT Top Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Competitive flow rates and pumping capabilities. Patented, proven design for superior reliability and durability. Handles solids, some solvents, hydrocarbons and corrosive conditions beyond the limits of electric pumps 5. Two-year warranty 5

57 AutoPump Top Inlet, Long APT Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 57" (5 cm) Actuation Level " (5 cm) Liquid Discharge Inlet Inlet O.D.." (. cm) Also Available (." (. cm) Air Supply Exhaust Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Long AP Top Inlet Top. in. (. cm) (. in. Available) 57 in. (5 cm).5 lbs. (5. kg) 5. gpm (. lpm) - See Flow Rate Chart. -. gal (.7 -.L ) ft. (7 m) 5 - psi ( kg/cm) in. (5 cm) scf / gal.(. -.9 liters of air / fluid liter) - See Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal, Brass Stainless Steel, Viton, Acetal, Nylon Brass or Stainless Steel Barbs or Quick Connects Nylon / in. (9 mm) or in. (5 mm) OD / in. ( mm) OD 5/ in. ( mm) OD Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. Body O.D.." (. cm) Application Limits AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consider the AP and AP models. AP AutoPumps are warranted for two () years: % materials and workmanship. Maximum Temperature: F (9 C) ph Range: -9 Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 55

58 APT Top Inlet, Long AutoPump Flow Rates.75 inch (9 mm) O.D. Fluid Discharge Tubing. inch (5 mm) O.D. Fluid Discharge Tubing /-INCH I.D. TUBE /-INCH I.D. TUBE /-INCH I.D. TUBE -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 PSI. Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD 9 PSI 7 Kg/cm PSI 7 PSI. Kg/cm 5 Kg/cm O.D. TUBE FT PSI 7 Kg/cm PSI 7 Kg/cm. 9 mm O.D. TUBE 7 PSI PSI 5 Kg/cm. Kg/cm FT mm O.D. TUBE 9 mm O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH (5 cm) SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. 5 mm O.D. TUBE 7 PSI PSI. 5 Kg/cm Kg/cm FT. FT. ( cm) SUBMERGENCE OF PUMP HEAD 9 PSI 7 Kg/cm PSI 7 PSI. Kg/cm 5 Kg/cm FT mm O.D. TUBE PSI 7 Kg/cm. 5 mm O.D. TUBE 7 PSI PSI 5 Kg/cm. Kg/cm FT FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. 5 FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

59 AutoPump Top Inlet, Long APT Air Consumption..5. PSI 7 Kg/cm inch (9 mm) O.D. Fluid Discharge Tubing CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT inch (5 mm) O.D. Fluid Discharge Tubing. PSI 7 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm LITER OF AIR LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 57

60 APT Top Inlet, Short AutoPump Max. Flow O.D. Length. gpm (. lpm). in. (. cm) 7 in. (9 cm) Description The APT Top Inlet Short AutoPump is designed for moderate-duty remediation pumping applications with well casings ( cm) diameter and larger using available. (. cm) inlet. It is designed for applications requiring an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. Based on the original automatic air-powered well pump, proven worldwide over 5 years The AutoPump Heritage The APT Top Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Competitive flow rates and pumping capabilities. Patented, proven design for superior reliability and durability. Handles solids, some solvents, hydrocarbons and corrosive conditions beyond the limits of electric pumps 5. Two-year warranty 5

61 AutoPump Top Inlet, Short APT Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 7" (9 cm) Actuation Level " (7 cm) Liquid Discharge Inlet Inlet O.D.." (. cm) Also Available." (. cm) Air Supply Exhaust /" (9 mm) O.D. Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Short AP Top Inlet Top. in. (. cm) (. in. Available) 7 in. (9 cm) lbs. (.5 kg). gpm (. lpm) - See Flow Rate Chart. -.5 gal (. -.57L ) 75 ft. (. m) 5 - psi ( kg/cm) in. (7 cm). -. scf / gal.(. -. liters of air / fluid liter) - See Air Usage Chart.7 SpG (.7 g/cm) Fiberglass or Stainless Steel Stainless Steel, Acetal, HDPE, Brass Stainless Steel, Viton, Acetal, Nylon Brass or Stainless Steel Barbs or Quick Connects Nylon / in. (9 mm) or in. (5 mm) OD / in. ( mm) OD 5/ in. ( mm) OD Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. Body O.D.." (. cm) Application Limits AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consider the AP and AP models. AP AutoPumps are warranted for two () years: % materials and workmanship. Maximum Temperature: F (9 C) ph Range: -9 Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 59

62 APT Top Inlet, Short AutoPump Flow Rates.75 inch (9 mm) O.D. Fluid Discharge Tubing. inch (5 mm) O.D. Fluid Discharge Tubing /-INCH O.D. TUBE /-INCH O.D. TUBE /-INCH O.D. TUBE -INCH (5 cm) PSI PSI Kg/cm 5.7 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI PSI. Kg/cm 5.7 Kg/cm FT SUBMERGENCE OF PUMP HEAD FT. ( cm) SUBMERGENCE OF PUMP HEAD mm O.D. TUBE PSI PSI 5 7 Kg/cm. Kg/cm FT mm O.D. TUBE 9 mm O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH O.D. TUBE -INCH (5 cm) PSI. Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI PSI. Kg/cm 5.7 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD 9 SUBMERGENCE OF PUMP HEAD PSI 5.7 Kg/cm mm O.D. TUBE PSI PSI. Kg/cm 5.7 Kg/cm FT mm O.D. TUBE 5 mm O.D. TUBE FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

63 AutoPump Top Inlet, Short APT Air Consumption inch (9 mm) O.D. Fluid Discharge Tubing.5... PSI 5.7 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR.7 LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT PSI 5.7 Kg/cm.5.. inch (5 mm) O.D. Fluid Discharge Tubing CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) LITER OF AIR LITER PUMPED (STD L/LITER)..7 PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F

64 APB AutoPump Bottom Inlet, Long Max. Flow O.D. Length. gpm (. lpm).75 in. (.5 cm) 55 in. (9 cm) Description The AP Bottom Inlet Long AutoPump provides maximum capabilities and flow in a bottom inlet pump for (5 mm) diameter wells. It is offered in optional versions to handle even severe remediation and landfill pumping applications, and delivers flow rates up to. gpm (. lpm). The AP Long Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years The AutoPump Heritage The AP Bottom Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. The industry leader in reliability, durability, flow rate and depth capability in an automatic pump for -inch wells. Handles solids, hyrocarbons, solvents, corrosive conditions, viscous fluids and landfill liquids. One-year warranty

65 AutoPump Bottom Inlet, Long APB Pump Dimensions Specifications & Operating Requirements Liquid Discharge Exhaust Air Supply Model Liquid Inlet Location OD Length Overall (pump & fittings) Length Overall, w / Extended Screen Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage " - Long AP Bottom Inlet Bottom.75 in. (.5 cm) 55 in. (9 cm) 57 in. ( cm) 7. lb (. Kg). gpm (. lpm) - See Flow Rate Chart. -.7gal (. -. L) ft (9. m) 5 - psi ( kg/cm) 5 in. (.9 cm). -.5 scf / gal. (. -. liters of air / fluid liter) See Air Usage Chart Length Overall, with Screen 55" ( cm) Actuation Level 5" (.9 cm) Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust.7 SpG (.7 g/cm) Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon 5/ in. ( mm) OD / in. (9.5 mm) OD / in. ( mm) OD Nitrile / in. ( mm) ID / in (. mm) ID / in. (9.5 mm) ID Inlet O.D..75" (.5 cm) Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (base model) Base model AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consult QED about AP upgrades. AP AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

66 APB AutoPump Bottom Inlet, Long Flow Rates / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm. PSI 7 PSI Kg/cm 5 Kg/cm FT mm /-INCH PSI 7 Kg/cm. PSI Kg/cm 7 PSI 5 Kg/cm FT mm FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH. PSI 7 Kg/cm. PSI 7 PSI Kg/cm 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

67 AutoPump Bottom Inlet, Long APB Air Consumption PSI 7 Kg/cm / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 5

68 APB AutoPump Bottom Inlet, Short Max. Flow O.D. Length. gpm ( lpm).75 in. (.5 cm) in. (5 cm) Description The AP Bottom Inlet Short AutoPump provides maximum capabilities and flow in a bottom inlet pump for (5 mm) diameter wells. It is offered in optional versions to handle even severe remediation and landfill pumping applications, and delivers flow rates up to. gpm ( lpm). The AP Short Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years The AutoPump Heritage The AP Bottom Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. The industry leader in reliability, durability, flow rate and depth capability in an automatic pump for -inch wells. Handles solids, hyrocarbons, solvents, corrosive conditions, viscous fluids and landfill liquids. One-year warranty

69 AutoPump Bottom Inlet, Short APB Pump Dimensions Specifications & Operating Requirements Length Overall, with Screen " ( cm) Actuation Level " (5 cm) Liquid Discharge Exhaust Air Supply Inlet Model Liquid Inlet Location OD Length Overall (pump & fittings) Length Overall, w / Extended Screen Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Short AP Bottom Inlet Bottom.75 in. (.5 cm) in (5 cm) 5. in (9cm) 5. lb (. Kg). gpm ( lpm).5 -. gal (.9 -. L) ft (9. m) 5 - psi ( kg/cm) in. (5 cm).9-.5 scf/gal (.9-9. liters of air/fluid liter see Air Usage Chart.7 SpG (.7 g/cm) Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon 5/ in. ( mm) OD / in. (9.5 mm) OD / in. ( mm) OD Nitrile / in. ( mm) ID / in (. mm) ID / in. (9.5 mm) ID O.D..75" (.5 cm) Material upgrades available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride Application Limits (base model) Base model AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consult QED about AP upgrades. AP AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

70 APB AutoPump Bottom Inlet, Short Flow Rates / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI Kg/cm FT. ( cm) SUBMERGENCE OF PUMP HEAD PSI 7 Kg/cm 7 PSI 5 Kg/cm FT. mm /-INCH mm PSI 7 Kg/cm. PSI Kg/cm 7 PSI 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD. /-INCH PSI 7 Kg/cm. PSI Kg/cm 7 PSI 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE.

71 AutoPump Bottom Inlet, Short APB Air Consumption CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI Kg/cm PSI. 7 Kg/cm LITER OF AIR.7 LITER PUMPED. (STD L/LITER).5 7 PSI Kg/cm FT / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 9

72 APT Top Inlet, Long AutoPump Max. Flow O.D. Length.9 gpm (7. lpm).75 in. (.5 cm) 57 in. ( cm) Description The AP Top Inlet Long AutoPump provides maximum capabilities and flow in a top inlet pump for (5 mm) diameter wells requiring an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. It is offered in optional versions to handle even severe remediation and landfill pumping applications, and delivers flow rates up to.9 gpm (7. lpm). The AP Long Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The industry leader in reliability, durability, flow rate and depth capability in an automatic pump for -inch wells The AutoPump Heritage The AP Top Inlet Long AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Handles solids, hyrocarbons, solvents, corrosive conditions, viscous fluids and landfill liquids. One-year warranty 7

73 AutoPump Top Inlet, Long APT Pump Dimensions Specifications & Operating Requirements Length to Top of Fittings 57" ( cm) Actuation Level 5" ( cm) Liquid Discharge Inlet Exhaust Air Supply Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust " - Long AP Top Inlet Top.75 in. (.5 cm) 57 in. ( cm) 7. lbs. (. kg).9 gpm (7. lpm) - See Flow Rate Chart. -.7 gal (. -.l) ft (9. m) 5 - psi ( kg/cm) 5 in. ( cm) scf / gal.(. -.7 liters of air / fluid liter) - See Air Usage Chart.7 SpG (.7 g/cm) Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon 5/ in. ( mm) OD / in. (9.5 mm) OD / in. ( mm) OD Nitrile / in. ( mm) ID / in (. mm) ID / in. (9.5 mm) ID Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings. PVDF - Polyvinylidene Fluoride O.D..75" (.5 cm) Application Limits (base model) Base model AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consult QED about AP upgrades. AP AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

74 APT Top Inlet, Long AutoPump Flow Rates / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI 7 Kg/cm.. mm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH PSI 7 Kg/cm. PSI 7 PSI Kg/cm 5 Kg/cm FT mm FT. ( cm) SUBMERGENCE OF PUMP HEAD /-INCH. PSI 7 Kg/cm. PSI 7 PSI Kg/cm 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. 7

75 AutoPump Top Inlet, Long APT Air Consumption / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing).. PSI 7 Kg/cm CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI 5 Kg/cm. 7.5 LITER OF AIR.7 LITER PUMPED (STD L/LITER) PSI Kg/cm FT Bishop Circle West Dexter, MI USA... F info@qedenv.com 7

76 APT Top Inlet, Short AutoPump Max. Flow O.D. Length. gpm ( lpm).75 in. (.5 cm) 5 in. (9 cm) Description The AP Top Inlet Short AutoPump provides maximum capabilities and flow in a top inlet pump for (5 mm) diameter wells having shorter water columns and/or the need to pump down to lower water levels, compared to full-length pumps. It is designed for applications requiring an elevated inlet, such as pumping total fluids from wells contaminated with LNAPLs. It is offered in optional versions to handle even the most severe remediation and landfill pumping applications, and delivers flow rates up to. gpm ( lpm). The AP Long Bottom Inlet AutoPump is complemented by the most comprehensive selection of accessories to provide a complete system to meet sitespecific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs. Advantages. The original automatic airpowered well pump, proven worldwide over 5 years. The industry leader in reliability, durability, flow rate and depth capability in an automatic pump for -inch wells The AutoPump Heritage The AP Top Inlet Short AutoPump is part of the famous AutoPump family of original automatic air-powered pumps, developed in the mid 9s specifically to handle unique pumping needs at remediation and landfill sites. Over the years they ve proven their durability at thousands of sites worldwide. AutoPumps are designed to handle difficult pumping challenges that other pumps can t, such as solvents, suspended solids, corrosives, temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systems offer the most complete range of tubing, hose, connectors, caps and accessories to help your installation go smoothly. This superior pumping heritage, application experience and support back up every AutoPump you put to work on your project.. Handles solids, hyrocarbons, solvents, corrosive conditions, viscous fluids and landfill liquids. One-year warranty 7

77 AutoPump Top Inlet, Short APT Pump Dimensions Specifications & Operating Requirements Model Liquid Inlet Location OD Length Overall (pump & fittings) Weight Max. Flow Rate " - Short AP Top Inlet Top.75 in. (.5 cm) 5 in. (9 cm) 5.7 lbs (. kg). gpm (. lpm) Length to Top of Fittings 5" (9 cm) Actuation Level " (79 cm) Liquid Discharge Inlet Exhaust Air Supply O.D..75" (.5 cm) Pump Volume / Cycle Max. Depth Air Pressure Range Min. Actuation Level Air Usage Min. Liquid Density Standard Construction Materials Pump Body Pump Ends Internal Components Tube & Hose Fittings Fitting Type Tube & Hose Options Tubing Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Hose Material Sizes - Liquid Discharge Pump Air Supply Air Exhaust Material upgrages available Applies to QED supplied tubing; other tubing sources may not conform to QED fittings gal (.9 -. l) ft (9. m) 5 - psi ( kg/cm) in. (7.7 cm) scf/gal (.9-9. liters/fluid liter) See Air Usage Chart.7 SpG (.7 g/cm) Stainless Steel Stainless Steel Stainless Steel, Viton, PVDF Brass or Stainless Steel Barbs or Quick Connects Nylon 5/ in. ( mm) OD / in. (9.5 mm) OD / in. ( mm) OD Nitrile / in. ( mm) ID / in (. mm) ID / in. (9.5 mm) ID PVDF - Polyvinylidene Fluoride Application Limits (base model) Base model AP AutoPumps are designed to handle the application ranges described below. For applications outside this range, consult QED about AP upgrades. AP AutoPumps are warranted for one () year: % materials and workmanship. Maximum Temperature: 5 F (5 C) ph Range: -9 Solvents and Fuels: diesel, gasoline, JP-JP, # heating oils, BTEX, MTBE, landfill liquids 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 75

78 APT Top Inlet, Short AutoPump Flow Rates / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) -INCH (5 cm) SUBMERGENCE OF PUMP HEAD /-INCH. PSI. 7 Kg/cm PSI 7 PSI Kg/cm 5 Kg/cm FT FT. ( cm) SUBMERGENCE OF PUMP HEAD mm /-INCH PSI 7 Kg/cm FT. ( cm) SUBMERGENCE OF PUMP HEAD.. PSI Kg/cm 7 PSI 5 Kg/cm FT. mm. /-INCH PSI Kg/cm.. PSI 7 Kg/cm. 7 PSI 5 Kg/cm FT mm FLOW RATES MAY VARY SITE CONDITIONS. CALL QED FOR TECHNICAL ASSISTANCE. 7

79 AutoPump Top Inlet, Short APT Air Consumption CUBIC FEET OF AIR GALLON PUMPED (SCF/GAL) PSI Kg/cm PSI 5 Kg/cm. PSI 7 Kg/cm FT / inch ( mm) (Equivalent to 5/-Inch O.D. Tubing) LITER OF AIR.7 LITER PUMPED. (STD L/LITER).5 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 77

80 Tubing & Hose AutoPump Model Type Material Liquid Discharge Size Air Suppy Size Exhaust Size Maximum Pressure Maximum Depth Minimum Bend Radius HIFLOTUBE Jacketed -Tube set Nylon.5 OD / OD 5/ OD PSI feet ( mm) ( mm) ( mm) ( kg/cm ( m) ( cm) STDTUBE Jacketed -Tube set Nylon OD / OD 5/ OD PSI feet 7 (5. mm) ( mm) ( mm) ( kg/cm ) ( m) ( cm) APTUBE -Tube set Nylon 5/ OD / OD / OD PSI feet.5 ( mm) (9.5 mm) ( mm) ( kg/cm ) ( m) (.5 cm) HIPSIHOSE -hose set Nitrile ID / ID / OD PSI feet (5. mm) (9.5 mm) ( mm) ( kg/cm ) ( m) ( cm) HIFLOHOSE -hose set Nitrile ID / ID / OD PSI feet (5. mm) (9.5 mm) ( mm) (7 kg/cm ) ( m) ( cm) STDHOSE -hose set Nitrile / ID / ID / OD PSI feet 7 ( mm) (9.5 mm) ( mm) ( kg/cm ) ( m) ( cm) APHOSE -hose set Nitrile / ID / ID / ID PSI feet 5 ( mm) ( mm) (9.5 mm) ( kg/cm ) ( m) ( cm) Advantages All dimensions of QED tube, hose and fittings are carefully designed and controlled to ensure high flow capacity, easy assembly, high pullout strength and leak-tight connections Innovative jacketed nylon tubing is highly regarded by experienced users for its light weight, smooth profile and ease of handling QED offers an unmatched range of connector fitting options to make installation and maintenance easier and more efficient 7 QED offers the choice of jacketed nylon tubing or hose sets for downwell use, and single tubes and hoses for surface runs to fit each project s needs. The jacketed nylon tubing is an exclusive developed by QED that encloses all of the nylon tubes inside a strippable nylon outer cover, a convenient package designed to provide lighter weight, increased chemical resistance, smoother handling and a smaller profile in the well. For applications where the tighter bend radius of hose is preferred, hose sets are offered in several sizes. Other hose and tube materials are available for special applications. The choice of hose and tube connection fittings used on pumps, caps and other components can make an important difference in the ease and quality of installation and service on your project. That s why QED offers a variety of connecting fitting types and materials, including quick-connects in both brass and stainless steel. Note: All QED tube, hose and fitting combinations are engineered specifically to provide user safety, high pullout strength, ease of installation, and leak tight connections for maximum assurance that the pumping system goes in right and stays trouble-free. It is especially important that the mating diameters and the tolerances of fittings, tubes and hoses be carefully controlled to ensure a fit that is snug yet doesn t damage the hose or tube due to excessive stretching. Don t trust your project to general purpose tubing, hose, and fittings that weren t specifically designed to work together.

81 AutoPump AutoPump Well Caps Vacuum seal well cap with brass quick connects, filter regulator and pump cycle counter Hundreds of wellhead cap and flange combinations are available from QED on a standard and custom basis to fit site needs and ease installation and maintenance. The table below lists some of our most commonly chosen wellhead assemblies. Our assemblies are based on the know-how gained through our years experience and thousands of installations. Besides connecting to the pump tubing or hose, wellhead assemblies have to be designed for safety, equipment support strength, pump level adjustment, access for data and sample collection, and durability. Call us for more detailed information. Vacuum Cap Seal Quick connect fitting available in brass or stainless steel Custom flange Filter Regulator see page 9 Compression fitting for pass-through hose or tubing. Available in nylon Pump Cycle counter see page Wellhead Assembly Description Fitting Types (hose & tubing) Fitting Materials Well Diameters Open-hole cap Non-sealing cap with open passthrough holes for hoses; allows easy pump height adjustment with support rope/cable No fittings,,, custom (5,, 5 mm) Slip Non-sealing cap with fittings for connection to air supply and liquid discharge lines quick-connects, compression fittings Brass, SS, poly,,, custom (5,, 5 mm) Vacuum Seal Sealing cap with fittings for connection to air supply and liquid discharge lines quick-connects, compression fittings Brass, SS, poly,,, custom (5,, 5 mm) Flange Sealing flange with fittings for connection to air supply and liquid discharge lines quick-connects, compression fittings Brass, SS, poly Custom 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com 79

82 Flow Counters AutoPump Cycle Counter The Cycle Counter detects and displays each AutoPump cycle via the pulse of air that occurs in the supply line. Since the liquid volume delivered by each pump cycle is relatively consistent for a given well condition, the total liquid volume delivered can be monitored with these cycle counts. An important advantage of the Cycle Counter method is its long-term reliability and low maintenance, since it requires no contact with the pumped fluid and no extra components in the liquid flow path. Cycle Counters can also be ordered with an electronic pulse output to support automated flow data collection. Cycle Counter Specifications Type: Magnetic piston/spring Readout: Direct digital (remote option), non-resettable Maximum Pressure: psi ( kg/cm ) End options: NPT, barb, quick connect

83 AutoPump Air Supply Filter regulators Filter regulators are recommended for each pump at the wellhead to economize on system air consumption, allow control of pump flow rate, and reduce service needs caused by air system debris and contaminants. These high quality filter regulators are coated on the inside to prevent corrosion from condensed moisture. All QED well caps and flanges include mounting provisions for these filter regulators, and other mounting options are available. Compressor Sizing A compressed air supply is required to power AutoPumps. Estimation of the fluid flow rates and air consumption of the AutoPumps and sizing the fluid lines, air lines, and air compressor involves a number of factors. Our application specialists are ready to assist you. The flow rates and air consumption for the AutoPumps can be compared by using the charts provided in this catalog for each model. The flow rate and air use curves in this catalog are based on pumping to atmospheric pressure at the wellhead, and do not take into account any liquid piping system backpressures due to elevation changes or fluid friction. Finally, there are some initial guidelines for air compressors. Most importantly, follow all application guidelines of the compressor manufacturer. A piston compressor may be a start / stop type or a constant run type. The tank (receiver) must be large enough, particularly for the start / stop type. The motor should not turn on more times an hour than recommended by the manufacturer. And start/stop compressors are typically assigned a 5% maximum duty cycle, meaning that the compressor is sized to provide twice the maximum air demand of the entire AutoPump system. Rotary screw compressors are designed for constant operation, and so are sized to just slightly exceed the maximum air supply requirement; it is recommended that rotary screw compressors not be grossly oversized because some types may be damaged by continued operation at low partial capacity. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

84 xxxxxxxxxxx xxxxxxxxxxx xxxxxxxxxxx AutoPump Tank Full Shutoffs Dual-Sensor Tank-Full Shut-Off (TFSO) System Wall Mounting Control Panel " x " x " (.5cm x 5. cm x 7.9 cm) ( lbs.) (9. kg) TANK FULL ND CATOR RESET TANK FULL Air Filters / Regulators COMPRESSOR xx xx xxxxxxxxx xxxxxxxxx xx xx xxxxxxxxx xx xxx xx xx TANK FULL SENSOR Air Supply To Pumps And / Or Other Control Panels Dual TFSO Sensor Hose Standard TFSO Unit Optional TFSO Unit Lengths Are Available For Different Tank Configurations Additional Single Sensor TFSO Units Can Be Added To The System PRODUCT RECOVERY TANK OIL / WATER SEPARATOR SURGE TANK QED s Tank-Full Shutoff senses when your recovery tank is full and automatically shuts off the pump air supply. It is all pneumatic for safety, and includes two independent level detection methods for failsafe operation. The Tank-Full Shutoff threads into standard NPT fittings on drums and tanks. Tank Full Shutoff Specifications: Power Supply: Fully pneumatic Level Sensor Type: Dual; Bubbler tube and float switch Air Usage:.7 psi (9. 5. kg/cm ) Tank Connection: -inch male NPT

85 AutoPump Application Data Sheet Environmental Systems A division of Severn T ent Laboratories, Inc. P.O. Box 7 Ann Arbor, MI -7 USA --- FAX (7) info@qedenv.com CUSTOMER INFORMATION Site Information Form QED USE ONLY Today's Date Quote Number Sales Order Number SITE INFORMATION Name: Title: Site Name: Company: Project Ref: Address: Company: Address: Phone: FAX: Phone: FAX: SENSORS REQUIRED Tank-Full Shut-Off Fluid Level High-Water Shut-Off Pump Cycle Counter Pumping Objectives ( attach additional information and diagrams). APPLICATION TYPE Total Fluids Dual Pump DNAPL LNAPL APPLICATION DESCRIPTION Condensate Leachate Properties of pumped fluids contaminants/viscosity/concentrations/ph/temperature/specific gravity/tds ( attach additional information. ) Please attach sketch of site, well and equipment layout. K L M N F E A B LNAPL Water C DNAPL Note: Please note any special characteristic on illustration above D H I J G A B C D E F G H I J K L M N WELL IDENTIFICATION NUMBER Well casing OD Well casing ID at wellhead Well casing ID at location of equipment Well casing to top of outer / vault casing Vault Dimensions Vault Depth Depth to bottom of the well Depth to top of screen Depth to bottom of the screen Sump length WELL DATA Depth to static water level Depth to top of LNAPL layer (if present) LNAPL thickness (if present) DNAPL thickness (if present) Desired fluid pumping rate Final drawdown level LNAPL removal rate (if present) Water / Leachate removal rate DNAPL removal rate (if present) Maximum daily water table fluctuation Casing Materials Well angle off vertical (% or degrees) Exhausting inside or outside the well Well under vacuum (Hg or HO) Any known material degradation (yes/no) The information provided on this form will be kept confidential by QED. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

86 Notes AutoPump

87 AutoPump Warranty QED AutoPump Warranty Period Summary Following is a summary of the warranty periods only for QED AutoPumps and accessories; this IS NOT the complete warranty. Contact QED for a copy of the complete warranty. AP+ AutoPumps (Long and Short lengths; Top and Bottom Inlets) warranted for five (5) years: % materials and workmanship. Low-Drawdown AutoPumps are warranted for one () year: % materials and workmanship.. AP AutoPumps (Long and Short lengths; Top and Bottom Inlets) warranted for two () years: % materials and workmanship.. AP AutoPumps (Long and Short lengths; Top and Bottom Inlets) warranted for one () year: % materials and workmanship.. Hoses, Tubing, Fittings, Well Caps and Flanges warranted for one () year: % materials and workmanship. There will be no warranty for application or material compatibility. 5. Pneumatic Data Modules / Logic Control Panels warranted for one () year: % materials and workmanship.. Parts and Repairs warranted for ninety (9) days: % materials and workmanship; when repairs are performed by QED or its appointed agent; from date of repair or for the full term of the original warranty, whichever is longer. Separately sold parts are warranted for ninety (9) days: % materials and workmanship. 55 Bishop Circle West Dexter, MI USA... F info@qedenv.com

88 Beyond the Pumps Success with a pumping system involves more than just the pumps. Over years of specialized air-powered pumping experience on thousands of sites with a broad range of applications and groundwater issues has allowed us to develop unequalled expertise and problem solving capabilities. QED technical experts will work with you on identifing the relevant site information to assure meeting your remediation and landfill pumping objectives. The equipment will be selected to meet your site-specific application. Accessories Downwell hose and tubing An array of connectors and fittings for ease of installation and service Mix of wellhead assemblies to meet site-specific needs Fluid discharge and air supply piping layouts and components Tank-full shut-off and other safety items and features Pump cycle counters Custom requirements Call us at --- for prompt, expert assistance on your pumping project needs. The World Leader in Air-Powered Pumps For Remediation, Landfills and Groundwater Sampling 55 Bishop Circle West 7 Alvardo Street Ste. 5 Dexter, MI San Leandro, CA 9577 USA USA T: T: 5.. F: F: 5.. info@qedenv.com info@qedenv.com Code 9 Rev /7

OPERATIONS MANUAL. Original Instructions. ATEX Version (doc # ) (3/26/15)

OPERATIONS MANUAL. Original Instructions. ATEX Version (doc # ) (3/26/15) AutoPump Ultra. OATIONS MANUAL Original Instructions ATEX Version 9 9- (doc # 9) (//) Copyright QED Environmental Systems, QED Environmental Systems - P.O. Box 7 / Bishop Circle W. Dexter, Michigan -7

More information

OPERATIONS MANUAL ATEX Version (doc # ) (Rev 12/10/12)

OPERATIONS MANUAL ATEX Version (doc # ) (Rev 12/10/12) Leaders in Environmental Compliance Products OATIONS MANUAL ATEX Version 6- (doc # 6 ) (Rev //) AutoPump + AutoPump Controllerless System (For inch wells or larger) DURABLE, DEPENDABLE, & DELIVERS Copyright

More information

OPERATIONS MANUAL. AutoPump

OPERATIONS MANUAL. AutoPump Leaders in Environmental Compliance Products OATIONS MANUAL D77- (doc # 77 ) (rev ) AutoPump AP+ DURABLE, DEPENDABLE, & DELIVERS AutoPump Controllerless System (For inch wells or larger) Copyright QED

More information

Free Product Recovery Equipment Catalog

Free Product Recovery Equipment Catalog Free Product Recovery Equipment Catalog The Broadest Range of Equipment for Effective Removal of Floating Hydrocarbons and DNAPL 8-624-226 www.qedenv.com The QED Advantage QED has been supplying the widest

More information

Landfill Gas Products

Landfill Gas Products Landfill Gas Products Toll Free: 800-624-2026 www.qedenv.com info@qedenv.com 2355 Bishop Circle West Dexter, MI 48130, USA Phone: 734-995-2547 Fax: 734-995-1170 1670 Alvarado Street Ste. 5 San Leandro,

More information

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer Installation and Operation Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 10/19/12 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 9 8/31/06 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

Dewatering Landfill Gas Wells to Maximize LFG Collection

Dewatering Landfill Gas Wells to Maximize LFG Collection Dewatering Landfill Gas Wells to Maximize LFG Collection QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental Systems, Inc. 2013; all rights reserved.

More information

AP-4 AutoPump. Environmental Systems O P E R A T I O N S M A N U A L. AutoPump Controllerless System (for 4-inch wells or larger)

AP-4 AutoPump. Environmental Systems O P E R A T I O N S M A N U A L. AutoPump Controllerless System (for 4-inch wells or larger) O P E R A T I O N S M A N U A L AP-4 AutoPump AutoPump Controllerless System (for 4-inch wells or larger) PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only

More information

Geotech 1.66 Reclaimer Installation and Operation Manual

Geotech 1.66 Reclaimer Installation and Operation Manual Geotech 1.66 Reclaimer Installation and Operation Manual Rev. 2 6/23/03 Part # 26600137 TABLE OF CONTENTS Chapter 1: System Description...p. 0 Function and Theory...p. 0 System Components...p. 0 Chapter

More information

AR4 4 Auto-Reclaimer. Installation and Operation Manual. Rev 10/9/2017 Part #

AR4 4 Auto-Reclaimer. Installation and Operation Manual. Rev 10/9/2017 Part # AR4 4 Auto-Reclaimer Installation and Operation Manual Rev 10/9/2017 Part # 16600115 Table of Contents Section 1: System Description... 3 Function and Theory... 3 System Components... 4 Section 2: System

More information

AP-2 AutoPump. AutoPump Controllerless System (for 2-inch wells or larger)

AP-2 AutoPump. AutoPump Controllerless System (for 2-inch wells or larger) O P E R A T I O N S M A N U A L AP-2 AutoPump AutoPump Controllerless System (for 2-inch wells or larger) PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only

More information

Geotech 1.66 Reclaimer

Geotech 1.66 Reclaimer Geotech 1.66 Reclaimer Installation and Operation Manual Rev 7/1/18 Part # 66 Table of Contents DOCUMENTATION CONVENTIONS... Section 1: System Description... 3 Section : System Installation... 4 Section

More information

Geotech 3.5 Reclaimer Installation and Operation Manual

Geotech 3.5 Reclaimer Installation and Operation Manual Geotech 3.5 Reclaimer Installation and Operation Manual Rev. 2 6/23/03 Part # 26600112 TABLE OF CONTENTS Chapter 1: System Description...p. 0 Function and Theory...p. 0 System Components...p. 0 Chapter

More information

Geotech 3.5 Auto-Reclaimer

Geotech 3.5 Auto-Reclaimer Geotech 3.5 Auto-Reclaimer Installation and Operation Manual Rev 6/20/12 Part # 16600115 Table of Contents Section 1: System Description... 3 Function and Theory.. 3 Section 2: System Installation. 6

More information

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring

More information

Pump On Demand. Skimmer System

Pump On Demand. Skimmer System Pump On Demand Skimmer System POD (Pump on Demand) Skimmer System Application Out-of-the-box LNAPL recovery in 2-inch and larger-diameter wells. The POD Skimmer model TR-610 recovers light-end hydrocarbons

More information

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps Portable MicroPurge R PATENT PENDING Sample Pro Portable MicroPurge Pump User's Guide P/N 98 REV. -24-03 The World Leader in Air Powered For Remediation, Landfills and Ground Water Sampling Ground water

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

ULSE. Installation and Operation Manual PNEUMATIC PUMPING SYSTEMS. Patent No

ULSE. Installation and Operation Manual PNEUMATIC PUMPING SYSTEMS. Patent No UMP ULSE PNEUMATIC PUMPING SYSTEMS Patent No. 5147185 Installation and Operation Manual P/N 3575 3/5/15 R INTRODUCTION ULSE UMP R PNEUMATIC PUMPING SYSTEMS The Pulse Pump system from QED Environmental

More information

PX800 M E T A L PX800 PERFORMANCE WIL T-08

PX800 M E T A L PX800 PERFORMANCE WIL T-08 PX800 M E T A L PX800 PERFORMANCE WIL-11220-T-08 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete

More information

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Low-pressure diaphragm pumps for product feeding Feeding

Low-pressure diaphragm pumps for product feeding Feeding s for product feeding Feeding Low pressure diaphragm pumps The ZIP and UNICA pneumatic double diaphragm pumps were designed specifically for reduced air consumption coupled with better performance and

More information

STAINLESS STEEL GRAND SERIES

STAINLESS STEEL GRAND SERIES STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges

More information

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company C.R.I. PUMPS DEEP WELL SUBMERSIBLE PUMPS EVERGREEN SERIES - 5Hz An ISO 91 & 141 Company Submersible Pumps C.R.I. Submersible Pumps are the products of the expertise gained from over four decades of experience,

More information

Marschalk Model # 94000

Marschalk Model # 94000 Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...

More information

ADDP. Surface Mounted Automatic Double diaphragm Pump

ADDP. Surface Mounted Automatic Double diaphragm Pump O P E R A T I O N S Environmental Systems ADDP Surface Mounted Automatic Double diaphragm Pump M A N U A L PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only

More information

APDM. AutoPump Data Module. Well Monitoring Module

APDM. AutoPump Data Module. Well Monitoring Module O P E R A T I O N S M A N U A L PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 AutoPump Data Module Well Monitoring Module (800) 624-2026 North America Only (734) 995-2547 Tele. (734) 995-1170

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

PX1 PX1 PERFORMANCE M E T A L WIL T-12

PX1 PX1 PERFORMANCE M E T A L WIL T-12 PX1 M E T A L PX1 PERFORMANCE WIL-10300-T-12 Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility never before

More information

Geotech Portable Bladder Pumps Installation and Operation Manual

Geotech Portable Bladder Pumps Installation and Operation Manual Geotech Portable Bladder Pumps Installation and Operation Manual Rev. 1 09/22/04 Part # 11150272 Table of Contents System Description... p. 02 Function and Theory...p. 02 System Components... p. 02 System

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Sanitizers. Sanitizers. Sanitizers for Pools & Spas Sanitizers Sanitizers for Pools & Spas 213 213 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

5 Gallon Pressure Pot with HVLP Spray Gun and Hose California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,

More information

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control MicroPurge Low-Flow Pump Control Sampling Equipment Catalog 10 MicroPurge Controls The MicroPurge Controller (U.S. Patent Number 6,508,310) revolutionizes low-flow sampling with advanced logic control

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02 PX4 P L A S T I C PX4 PERFORMANCE WIL-10161-T-02 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

PARTS LIST FOR CM MMB

PARTS LIST FOR CM MMB PARTS LIST FOR CM-4200-0MMB Displacement: 420 cc Pump Oil Grade: Mi-T-M Pump Oil #AW-4085-0016 Pump Oil Capacity: 13.4 oz. Nozzle Size: # 3.5 1 This Parts Listing has been compiled for your benefit. You

More information

Geotech Bladder Pumps Installation and Operation Manuals

Geotech Bladder Pumps Installation and Operation Manuals Geotech Bladder Pumps Installation and Operation Manuals Rev 12/17/12 Part # 21150035 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 2 FUNCTION AND THEORY... 2 SYSTEM COMPONENTS... 3 Bladder Cartridge

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

Tube Puller CP/CPS series. Pullers designed with cutting edge technology

Tube Puller CP/CPS series. Pullers designed with cutting edge technology Q U A L I T Y T U B E T O O L S www.krais.com CP/CPS series Pullers designed with cutting edge technology Q U A L I T Y T U B E T O O L S w w w. k r a i s. c o m MAIN FEATURES All new CP collet type and

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

kysimply Unique Single Seat

kysimply Unique Single Seat . kysimply Unique Single Seat Unique SSV Long Stroke General Information The new generation that meets the highest demands of your process in terms of hygiene and safety. Unique Single Seat Valves are

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Sanitizers. Sanitizers. Sanitizers for Pools & Spas for Pools & Spas 207 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely,

More information

Impeller Replacement -

Impeller Replacement - 10 www.jabsco.com Introduction Jabsco - The Original Impeller Jabsco flexible impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general purpose

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02 PX400 P L A S T I C PX400 PERFORMANCE WIL-11240-T-02 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Right-Angle Tube Roller Model

Right-Angle Tube Roller Model SPECIFICATIONS Model no. Free Speed (RPM) Throttle Rotation Max. Torque Ft-Lb Air Pressure psi Air Inlet Hose Air Flow @Free Speed Spindle Weight 909-1700 95 Lever type Reversible 240 90 1/2 NPT 1/2 I.D.

More information

pvc well casing & drop pipe

pvc well casing & drop pipe C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project

INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives Project "INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

12 Impeller Replacement

12 Impeller Replacement 144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general

More information

Compact Transfer Pump

Compact Transfer Pump Munster Simms Engineering, better known under the product brand name Whale, is an independent company engaged in the design, manufacture, marketing and selling of pumps, valves, faucets and plumbing (water

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT MAXIMATOR GmbH MAXIMATOR is one of the world leading manufacturers

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1) SPECIFICATION // DATA SHEET WATER DRAIN VALVE 1 Introduction The Water Drain Valve was developed for a major oil company to detect the presence of fuel when discharging water through the drain line of

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal 2 C Lite CAD SERIES Patented CAD-2 diaphragm technology Unique 3 piece construction Reinforced Plastic Connection Durable continuous strand fiberglass sealed with epoxy resin NSF Standard 61, CE/PED, WRAS,

More information

Gas Hydraulic Valve Operator

Gas Hydraulic Valve Operator A L o ng E xper ience in Energy Equipmen t and One G o al: T he C u sto mer s Sa tisfa c tion Gas Hydraulic Valve Operator Rugged, reliable controls are at the heart of any good actuator. In the pipeline

More information

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

NEW Edge Series Products: OUTFITS and REGULATORS

NEW Edge Series Products: OUTFITS and REGULATORS NEW Edge Series Products: OUTFITS and REGULATORS NOW Including ESS3 Models and More Edge Series Outfits User Friendly Advanced Design Outstanding Flow Performance Unsurpassed Safety www.victoredge.com

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

FloWash. Industrial Filter Cart

FloWash. Industrial Filter Cart OPERATION AND MAINTENANCE MANUAL FloWash Industrial Filter Cart Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas

More information

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX COMPLIANCE ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX compliance pursuant to Directive 94/9/EC for its ranges of ADB BOXER pneumatic diaphragm pumps.

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC. Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Adjustable. Unloader Valve. O&M Manual. Part #

Adjustable. Unloader Valve. O&M Manual. Part # Adjustable Unloader Valve O&M Manual Unloader Valve Part #60-020-361 ADVANCED PRESSURE SYSTEMS 701 S. Persimmon St., Suite 85 - Tomball, TX 77375 Toll Free in North America: (877) 290-4277 Phone: (281)

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

ACTIVE REMEDIATION 2 F.A.P. Plus 2 Electrical Skimmer 6. PASSIVE REMEDIATION 7 Passive Skimmer 7 SoakEase 8

ACTIVE REMEDIATION 2 F.A.P. Plus 2 Electrical Skimmer 6. PASSIVE REMEDIATION 7 Passive Skimmer 7 SoakEase 8 DURHAM GEO SLOPE INDICATOR ACTIVE REMEDIATION 2 F.A.P. Plus 2 Electrical Skimmer 6 PASSIVE REMEDIATION 7 Passive Skimmer 7 SoakEase 8 SUBMERSIBLE PUMPS 10 MVP Series 10 Evacuator II 14 SEP IV Electric

More information

TWISTER Low Speed Surface Aerator

TWISTER Low Speed Surface Aerator Expanded AEROMIX Product Line Includes All Major Wastewater Aeration Technologies TWISTER Low Speed Surface Aerator Highest Oxygen Transfer The proven TWISTER Low Speed Surface Aerator delivers unmatched

More information