1 API Commonly Used & Relevant Spec's & RP notes: API RP 2D sect C.4.1.2: 4-yearly load test of BOP crane to SWL +5 Ton and NDT inspection post load test. API Spec 4F: Crown Block Data Plate section API Spec 4F: Sub-structure Data Plate section API Spec 4F: Mast Data Plate section API Spec 4F: Guy wire Tension etc, ref Table A1, Fig A. API Spec 4F: Raising cylinders and winches test to 150% W/Press for 10 mins, Sect API Spec 4F: Mast welding procedures (coded welder AWS D1.1) Section 9. API Spec 6A: Threaded pipe connections HP piping, Section Table 1. API RP 7C: Combustible Engine Exhaust Flanges Flameproof gaskets within 100'. API Spec 7F: Chain elongation. API Spec 7K Drilling & Well service equipment. API Spec7K: sect 6 welding requirements. Section 8: Test load paths written passage for each item. Section 10: Markings for load test equipment. Section 11: Documentation (should be supplied with equipment). API RP 8B: Maintenance repair & remanufacture Hoisting equipment and periodic inspection schedule (Drilling load path inspection frequency) Table 1. Section Primary load path equipment listed under scope (at beginning of paper). API Spec 8C Drilling and Hoisting equipment API Spec 8C: Drill Line Sheave Depth etc, Section API Spec 9A Wire ropes. (Drill line should show API on drum for line). API RP 9B: Ton Miles Drill line, section 5. API Spec 16 D BOP drillers panel rig floor. Section: 2: API Spec 16D Two hand operation for valve control at remote panels: sect a. API Spec 16 D Alternate electric power supply required. Section: 4: & section 2: & Section 2: for battery / ups supply required. API Spec 16D Pump requirements Section API Spec 16D: BOP Control response times Section: & API RP 16 E: Section: API Spec 16D BOP pump system test time 15 minutes Section: API RP 16E section

2 API Spec 16D Electrical installation requirements and Ex 3 rd party authority testing. API Spec 16D Control hose flame test Section API 16D 11.4 MANUFACTURER S IDENTIFICATION MARKINGS Manufacturers shall affix at least one permanent marking containing, as a minimum, the manufacturer s name or mark, and the part number or other suitable unique identification on each control system, subsystem and component provided. Manufacturers may affix other markings at their discretion. API Spec 16E BOP Control hoses flame resistant section API Spec 16 E Rig floor BOP remote panel required, Section 2.6. API Spec 16 E Devices used to prevent pump system over-pressurization should be installed directly in the control system supply line to the accumulators and should not have isolation valves or any other means that could defeat their intended purpose. API RP 53 Various BOP and well control. API RP 54: Fire Extinguishers required. API RP 54 Sect Personnel fall protection Anchor points min rated 5400lbs. API RP 54 Elect hand tools double insulated or grounded Sect API RP 54: Electrical hand pneumatic tools dead man switch or no lockable ON switch Sect API RP 54: Lock out tag out Section API RP 54: Sect 9.15 Engine Emergency shutdown Weekly test (air intake shutdown must be fitted) API RP 54: Mast Ladders 7" clearance etc, Section API RP 54: Engines within 100' spark arrestor required, Section and API RP 75, Appendix A. API RP 54 Cables to be installed to protect same from damage. Sect API RP 54: Cabin placement outside fall area guideline, Section API RP 54: Engine Kill required at drillers control, Section API RP 54 Sect: Guardrails, consisting of 42 in. (106.7 cm) high (nominal) top rail, intermediate rail, and posts, should be installed at the outer edge of any floor, platform, or walkway, that is 4 ft (1.2 m) or more above ground level or another floor or working level. A runway of 4 ft (1.2 m) or more above ground level shall be equipped with a guardrail. : Exceptions are as follows: a. Personnel egress (exit and entrance) openings. b. Catwalk and V-door opening when being used. c. Work station being used to rack tubular. d. Alternate arrangements providing equivalent safety are acceptable. API RP 54 Auxiliary Escape (Derrick man s escape) 6.10 API RP 54 (1999) Field welding shall not be permitted tongs, elevators bails etc Sect

3 API RP 54 Electrical hand tools shall be double insulated or grounded by NFRA70. Sect API RP 62: MODU emergency power requirements. API RP 500 & 505: Electrical Hazardous area classification, Section 10.4 Fig 29. API RP 574: Yearly Wall thickness testing of HP piping. API RP 576: PRV retest and calibration 2 yearly Sect: (Safety Valve) API RP 576: Valve Identification To minimize errors in the testing and handling of pressure relief valves, each should carry an identifying tag, stencil, plate, or other means to show its company equipment number. This number allows ready identification of the device's unit, the equipment that the device should be installed on, the device's set pressure, and the date of its last test (see Figure 37 for an example of an identifying tag). If a relief device cannot already be easily and correctly identified by a marking on it, it should be marked and identified as described above before it is removed from its equipment. Also see ASME Section VIII, Division 1, paragraph UG-129 for instructions on marking nameplates of pressure relieving devices. EX Electrical Equipment to IEC API S Test pressure measurement devices (including analogue gauges) shall be calibrated annually in accordance with OEM procedures. API S Devices used to prevent pump system over pressurization shall not have isolation valves or any other means that could defeat their intended purpose. API S Rupture disc(s) or relief valve(s) that do not automatically reset shall not be installed. API S Each pump system shall be protected from over pressurization by a minimum of two devices: One device, such as a pressure switch, to limit the pump discharge pressure so that it will not exceed the RWP of the control system; The second device, such as a certified relief valve, to limit the pump discharge pressure and flow in accordance with API 160. API 16 D Relief Valve Certificates Relief valves shall be separately tested and adjusted using a low flow rate tester comparable to a dead weight tester. A certificate of the relief valve setting and operation shall be provided indicating the set point and the pressure at which the relief valve reseats. Relief valves shall reseat within twenty five percent. of the set pressure. Relief valves shall additionally be type tested to determine the maximum flow rate through the relief valve without exceeding 11.5% of the relief valve's set pressure. API Standard SET PRESSURE TEST

4 All pressure relief valves shall be adjusted to the specified set pressure in accordance with the ASME Boiler and Pressure Vessel Code, the manufacturer s standard practice as published, or as designated by the purchaser. All set pressure adjustments shall be sealed. ASME B (h) Identification. The manufacturer shall establish the design pressure and temperature for each extruded outlet header and shall mark the header with this information, together with the symbol B31.3 (indicating the applicable Code Section) and the manufacturer s name or trademark. MSS SP 25 This standard marking system applies to valves, fittings, flanges, and unions used in piping connections which include (but are not limited to) flanged, soldered, brazed, threaded, or welded joints. IHS Standard The markings specified within this Standard Practice serve to identify the manufacturer, the rating designation, materials of construction, and special service limitations imposed by the manufacturer. They are used for product identification and to assist in proper application API RP 64: 2001 Recommended practice for diverter systems equipment and operations. - 2nd edition. API RP 7L: 1995 Procedures for inspection, maintenance, repair, and remanufacture of drilling equipment. - 1st edition. API Spec 16A: 2004 Specification for drill-through equipment. - 3rd edition. API Spec 16C: 1993 Specification for choke and kill systems. - 1st edition. API Spec 16D: 2004 Specification for control systems for drilling well control equipment and control systems for diverter equipment. - 2nd edition. API Spec 16D: Pump Systems The manifold pumping unit provides power fluid for all of the control system hydraulic functions. The same pumping unit may be used to provide fluid power for the control of both the BOP and diverter system. The manifold pumping unit shall comprise a minimum of two (2) pump systems with at least two (2) independent power systems. API STANDARD The same pump system(s) may be used to provide control fluid to control both the BOP stack and the diverter system. API Spec 16D Water-based hydraulic fluid: A control liquid mixture composed mainly of water with additives to provide lubricity, anti-foaming, anti -freeze, anti-corrosion and anti -bacterial characteristics.

5 API Std 16AR Repair and Remanufacture of Drill-through Equipment. - 1st edition. API Std 53:2012 Blowout Equipment Systems for Drilling Wells. - 4th edition. STAP-M-1-SS-13668:2002 BOP AND WELL CONTROL EQUIPMENT ACCEPTANCE MINIMUM REQUIREMENTS original equipment manufacturer OEM, API RP 53 and in API S l Installation, Operation, and Maintenance Manuals Manufacturer s installation, operation, and maintenance (IOM) manuals should be available on the rig for all the BOP equipment installed on the rig. Oil and Gas UK recommendations for critical spares page 36 section Requirements for spares. API S Equipment Data Book and Certification API RP Equipment Data Book and Certification API S53, para Any elastomer seals found to be outside the manufacturer's recommended expiration date shall be discarded and prohibited from use in BOP equipment systems. API S53 para and para , the OEM manual, The Energy Institute recommends in the Guidelines for the Management for the Integrity of Bolted Joints for Pressurized Systems, para that there must be sufficient provision for full thread engagement. The relief valves (Safety Valves) do not comply with API RP 576, para 6.3 where there is no identification tag present and the seals are broken Equipment Marking and Storage Marking and storage of sealing components of BOP systems shall be in accordance with API 6A. API 16A, or API 17D, as applicable, including identification marking of ring gaskets, bolts, nuts, clamps, and elastomeric seals Elastomeric seals shall be marked or tagged using the equipment manufacturer defined coding system At a minimum the markings shall include information regarding the Durometer hardness, generic type of compound, dates of manufacture and of expiration (month/year), Lot / serial number, manufacturer's part number, and the operating temperature range of the component Any elastomer seals found to be outside the manufacturer's recommended expiration date shall be discarded and prohibited from use in BOP equipment systems.

6 BLOWOUT PREVENTION EQUIPMENT SYSTEMS FOR DRI LLI NG WELLS Specialized components, including proprietary design BOP seals and packing units, shall be stored in accordance with the OEM's recommendations. API 6A June 2006 ERRATA 3 G. 2 Elevated temperature ratings The temperature ratings given in Table G. 1 may be used for equipment for service temperatures in excess of those covered by Clause 4. Table G.1 Temperature ratings Classification Operating temperature range X 18 to 180 C 0 to 350 F Y 18 to 345 C 0 to 650 F Spec 12 J: Oil Gas Separators Separators are equipped with gauge glasses or sight glasses to indicate one or two levels. A pressure gauge and thermometer well are usually installed on separators. API 16 D Specification Using the choke control system in a normal operating procedure, close the choke. The choke shall be completely closed in 30 seconds or less. 5. The choke shall operate from fully closed to fully open in 30 seconds or less. API 16 D Specification DESIGN REVIEW. Design documentation shall be reviewed and verified by qualified personnel other than those who created the original design DESIGN VERIFICATION. Manufacturers shall document their verification procedures and the results of performance verification of designs. Design verification is not required on APT flanges, hubs and ring gaskets. API 16 D Specification RANGE. Pressure measurements shall be made at not less than 25% nor more than 75% of the full pressure range of the pressure gauge. API 16 C Specification. Surface Manifold

7 IP 17 (a) More than one flow path through the choke manifold in case of blockage. The minimum nominal diameter of all components should be 3 inches. IP 17 Remotely controlled, power operated adjustable chokes for primary flow paths. Where the kill and choke lines are integrated through the choke manifold, e.g. subsea BOP systems and many surface BOP arrangements, the manifold should be configured so that these lines are interchangeable. The arrangement should permit high pressure pumping down the kill line while taking returns through the choke line. IP 17 In the event that the gas handling capacity of the MGS is exceeded a mud seal should be provided as a final barrier between the MGS and the downstream mud processing system. The system by-pass capacity is determined from the hydrostatic head of the mud seal and the size of the vent line. The mud seal may become contaminated with produced hydrocarbon liquids reducing its effective hydrostatic head. Circulating clean fresh mud from the pits through the mud seal can help prevent compromising the gas handling capacity. This is often referred to as a 'hot' mud injection system. IP 17 All chokes should discharge directly into an erosion nipple/spool. IP MGS instrumentation The MGS should be instrumented and controlled so that the gas handling capacity is not exceeded i.e. the liquid seal is not disturbed. Instrumentation by means of pressure gauges fitted in the MGS to give continuous monitoring should be coupled with visual/audio warning alarms once the pre-set by-pass overboard pressure is reached.

8 API Specification 16F for MARINE DRILLING RISER EQUIPMENT 13.4 Marking The riser spider will be marked using permanent low-stress, metal-impression stamping specifying a serial number that corresponds to a data sheet for the spider. The data sheet shall include as a minimum the manufacturer's name and part number and the maximum load rating. API Specification 16F for MARINE DRILLING RISER EQUIPMENT 13.1 Design, rating and testing Riser handling tools and spiders shall be designed considering the following loads: Maximum static load capacity Bending loads (during handling) API Spec 8C, PSL Riser Running Equipment 14.1 DESIGN, RATING AND TESTING Riser handling tools and spiders shall be designed considering the following loads: a. Maximum static load capacity. b. Bending loads (during handling). Handling tools for the riser and for the diverter, if used to support the riser and the BOP Stack, shall be designed, rated, and tested in accordance with API Spec 8C, PSL 2. The spider (and gimbal and shock absorber, if applicable) shall also be designed, rated, and tested in accordance with API Spec 8C. Handling tools for the riser and for the diverter, if used to support the riser and the BOP Stack, shall be designed for hoisting and lowering the riser system through the riser spider and rotary table. Riser hang-off spiders shall be rated to support the riser system and BOP Stack at the drill floor level. The riser joint shall be permanently marked using a low stress method. Marking shall include a serial number that corresponds to a data sheet for the joint and API Spec 16F (or API Monogram). The data sheet shall include as a minimum the manufacturer s name and part number, the maximum load ratings, and the asbuilt assembled weight excluding buoyancy and protectors. Syntactic foam buoyancy modules shall be pigmented or painted a highly visible colour with require markings printed indelibly on its surface. Serial numbers shall be located in a minimum of three places on each module: the outer surface, the inner surface, and the end of the module.

9 Each module shall be identified with a colour code for each depth rating as agreed by manufacturer and purchaser. The riser spider shall be marked using permanent low-stress, metal-impression stamping specifying a serial number that corresponds to a data sheet for the spider. The data sheet shall include as a minimum the manufacturer s name and part number, the maximum load rating, and indication of conformance to API Spec 16F (or API Monogram). Marking shall be in accordance with manufacturer s written specifications. API 17 H Design requirements The hot stab receptacle should be designed such that it does not fill with debris whilst not in use, for example, a passive blank may be provided, which is temporarily pushed out of the way by the insertion of the hot stab. Hot stab females can also be filled with blanking plugs to avoid debris ingress; where this is the case, a parking slot should be provided for the blank during use of the hot stab facility. API 16 D. 1.5 EMERGENCY BACKUP BOP CONTROL SYSTEMS. When the subsea control system is inaccessible or non-functional, an independent control system may be used to operate critical well control and/or disconnect functions. These systems have their own supply of power fluid. They include acoustic control systems, ROV (Remotely Operated Vehicle) operated control systems and LMRP recovery systems. API 6A Hidden marking Marking required on a connector OD that would be covered by clamps or other parts of the connector assembly shall be stamped in a visible location near the connector. API RP Accumulator Response Time. Response time between activation and complete operation of a function is based on BOP or valve closure and seal off. For surface installations, the BOP control system should be capable of closing each ram BOP within 30 seconds. Closing time should not exceed 30 seconds for annular BOPs smaller than 183/4 inches (47.63 cm) nominal bore and 45 seconds for annular preventers of 183/4 inches (47.63 cm) nominal bore and larger. Response time for choke and kill valves (either open or close) should not exceed the minimum observed ram close response time. API Specification 16 D. EFFECTIVE DATE, JANUARY Response Time Response time between activation and complete operation of a function is based on BOP or valve closure and seal off. For surface installations, the BOP control system shall be capable of closing each ram BOP within 30 sec. Closing time shall not exceed 30 sec. for annular BOPs smaller than 18 3/4 in. nominal bore and 45 sec. for annular preventers of 18 3/4 in. and larger. Response time for choke and kill valves (either open or close) shall not exceed the minimum observed ram close response time. Measurement of closing response time begins when the close function is activated at any control panel and ends when the BOP or valve is closed affecting a seal. A BOP may be considered closed when the regulated operating pressure has recovered to its nominal setting Response Time The control system for a subsea BOP stack shall be designed to deliver power fluid at sufficient volume and pressure to operate selected functions within allowable response times. The control system shall have a closing response time not exceeding 45 sec. for each ram BOP. Closing response time for each annular BOP shall not exceed 60 sec. Operating response time for each

10 choke and kill valve (either open or close) shall not exceed the minimum observed ram close response time. The response time to unlatch the riser (LMRP) connector shall not exceed 45 sec. API Specification 16 D. EFFECTIVE DATE, JANUARY Hose Reel Drum The hose reel drum radius shall be equal to or greater than the minimum bend radius recommended by the manufacturer of the subsea umbilical, for the type of service intended. The hose reel drum shall be equipped with a brake capable of overriding and stalling the motor. The brake should be capable of supporting the weight of the fully deployed subsea umbilical when it is suspended in water. The hose reel drum shall have a mechanical locking device that permits operation of the hose reel manifold (if equipped) and ability to connect the junction box when parked. API RECOMMENDED PRACTICE 64 (RP 64) SECOND EDITION, NOVEMBER 2001 REAFFIRMED, JANUARY Installation Test 5. A pressure integrity test (200 psig minimum) should be made on the diverter system after each installation. The tests may be made on parts of the system or on individual components of the system should certain components of the casing string or riser components not support a complete system test. The test should be stable for at least five minutes. Stainless Steel Basic Properties Galvanic Corrosion Takes Place When Two Dissimilar Metals Are Electrically Coupled In The Presence Of An Electrolyte: The electrolyte assisting in the transfer of the charged atoms / molecules necessary for the corrosion to take place, the more reactive of the two metals (the anode) will corrode in preference to the less reactive metal (the cathode), steel structures in the maritime environment are often protected by zinc anodes. The (more reactive) zinc corrodes and dissolves in the presence of the salt water (the electrolyte), thereby offering some anti-corrosion protection to the steel (cathode). The serviceable life of the steel is thus extended. The rate at which galvanic corrosion can proceed is governed by two key factors. Availability of electrolytic liquid (such as salt water) to facilitate ion transfer The relative exposed area of the two dissimilar metals that are exposed and electrically coupled in the electrolyte Stainless steel is less reactive than ordinary mild steel or cast iron, therefore the iron/steel will corrode via galvanic reaction (if the above conditions are met) protecting the stainless steel. - Remote control panels for operating the hydraulic control manifold from remote locations. REMOTE CONTROL PANELS GENERAL API RP 16 E. 2.6 A minimum of one remote control panel should be furnished. This is to ensure that there are at least two locations from which all of the system functions can be operated. The remote panel should be accessible to the driller to operate functions during drilling operations. The driller's remote control panel display should be physically arranged as a graphic representation of the BOP stack. Its capability should include the following: 1. Control all the hydraulic functions which operate the BOP's and choke and kill valves. ANSI/API Specification 16A Third Edition, June Acceptance of Drift Test.

11 The drift mandrel shall pass through the bore within 30 min without being forced. API STANDARD Choke lines shall be secured to withstand the dynamic effect of fluid flow and the impact of drilling solids. Supports and fasteners located at points where piping changes direction shall be capable of restraining pipe deflection. Special attention should be paid to the end sections of the line to prevent line whip and vibration. diverter The following response times shall be met by at least one of the surface/subsea power supplies: a) Close each ram BOP in 45 seconds or less; b) Close each annular BOP in 60 seconds or less; c) Unlatch the riser (LMRP) connector in 45 seconds or less; d) Response time for choke and kill valves (either open or close) shall not exceed the minimum observed ram close response time. API S For the pre-deployment BOP test (stump test), the annular(s) and VBR(s) shall be pressure tested on the largest and smallest OD drill pipe to be used in well drilling program. API S ROV Intervention The BOP stack shall be equipped with ROV intervention equipment that at a minimum allows the operation of the critical functions (each shear ram, one pipe ram, ram locks, and unlatching of the LMRP connector) Hydraulic fluid can be supplied by the ROV, stack mounted accumulators (which may be a shared system), or an external hydraulic power source that shall be maintained at the well site. The source of hydraulic fluid shall have necessary pressure and flow rate to operate these functions All critical functions shall be fitted with single-port docking receptacles designed in accordance with API 17H If multiple receptacle types are used, a means of positive identification of the receptacle type and function shall be required Frequency of testing and acceptance criteria shall be in accordance with Table 6 and Table All critical functions shall meet the closing time requirements in The following response times shall be met by at least one of the surface/subsea power supplies: a) Close each ram BOP in 45 seconds or less; b) Close each annular BOP in 60 seconds or less; c) Unlatch the riser (LMRP) connector in 45 seconds or less; d) Response time for choke and kill valves (either open or close) shall not exceed the minimum observed ram close response time.

5k Slickline Lightweight Pressure Control Equipment 4 ID

5k Slickline Lightweight Pressure Control Equipment 4 ID 5k Slickline Lightweight Pressure Control Equipment 4 ID Table of Contents 5k Slickline Lightweight Pressure Control Equipment 4 ID... 1 Hydraulic Slickline Stuffing Box... 3 Wireline Lubricators... 4

More information

IWCF Equipment Sample Questions (Surface Stack)

IWCF Equipment Sample Questions (Surface Stack) IWCF Equipment Sample Questions (Surface Stack) 1. During a well control operation 4000 psi was shut in below the middle pipe rams. Ram type BOP data: Model: Cameron U type Rated Working Pressure: 15000

More information

IWCF Equipment Sample Questions (Combination of Surface and Subsea Stack)

IWCF Equipment Sample Questions (Combination of Surface and Subsea Stack) IWCF Equipment Sample Questions (Combination of Surface and Subsea Stack) 1. Given the volumes below, how much hydraulic fluid will be required to carry out the following operations (no safety margin)?

More information

DRILLING HOSE SOLUTIONS

DRILLING HOSE SOLUTIONS DRILLING HOSE SOLUTIONS HIGH PRESSURE FLEXIBLE LINES FOR A WIDE RANGE OF DRILLING APPLICATIONS HIGH QUALITY - HIGH STANDARD WE DELIVER ACCORDING TO THE HIGHEST LEVELS OF SPECIFICATIONS AND STANDARDS WITH

More information

Last Updated: April 19, 2018

Last Updated: April 19, 2018 API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Last Updated: April 19, 2018 Standard Edition Section Inquiry # Question Reply 4.3.6 53-10-17 The cost of NDE/NDT inspection of some

More information

Completion Workover Riser System. Enabling efficient operations by reducing interface complexities and minimizes operational risk

Completion Workover Riser System. Enabling efficient operations by reducing interface complexities and minimizes operational risk Completion Workover Riser System Enabling efficient operations by reducing interface complexities and minimizes operational risk Well integrity with fatigue management were key drivers for our system design

More information

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Standard Edition Section Inquiry # Question Reply 4.3.6-10-17 API Std - Blowout Prevention Equipment Systems for Drilling Wells The cost of NDE/NDT inspection of some fasteners outweigh the cost to replace

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Standard Edition Section Inquiry # Question Reply

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Standard Edition Section Inquiry # Question Reply API Std - Blowout Prevention Equipment Systems for Drilling Wells Standard Edition Section Inquiry # Question Reply Last update: August 12, 2015 Question 1: In reference to API Standard requirement 4.4.3,

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING Contents All Products... Gb-1 Control Valves... Gb-2 Control Valve Actuators... Gb-3 Regulators... Gb-3 Relief Valves... Gb-4 Instruments, Switches, and Accessories... Gb-4 Products Covered by Battery

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells 4.3.6-10-17 API Std - Blowout Prevention Equipment Systems for Drilling Wells The cost of NDE/NDT inspection of some fasteners outweigh the cost to replace with new. Since this is the case, many equipment

More information

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. Page 1 of 7 CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD 1. SCOPE 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. 1.2 The piping system as used herein is

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

TABLE OF CONTENTS PART 2 - CONFINED SPACES

TABLE OF CONTENTS PART 2 - CONFINED SPACES May 11, 2006 TABLE OF CONTENTS PART 2 - CONFINED SPACES Page DEFINITIONS... 2-1 GENERAL... 2-2 RESPONSIBILITIES... 2-2 HAZARD ASSESSMENT AND WORK PROCEDURES... 2-3 IDENTIFICATION AND ENTRY PERMITS... 2-3

More information

1 Exam Prep. Tabs and Highlights

1 Exam Prep. Tabs and Highlights 1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,

More information

Subsea Safety Systems

Subsea Safety Systems Subsea Safety Systems The ELSA-HP has been developed to service the high pressure horizontal tree completion and intervention market. With systems designed and qualified up to 15,000 psi, 250 degf and

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Safety and Risk Engineering. HSE Case Implementation Clive Rawson

Safety and Risk Engineering. HSE Case Implementation Clive Rawson Safety and Risk Engineering HSE Case Implementation Clive Rawson Purpose ALARP Risk Assessment Major Accident Events Bowties Safety Critical Systems Performance Standards Implementation Getting HSE Case

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by

The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by Thank you Greg. 1 The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by Mr. Muhammad Sadiq, however in short,

More information

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 3501 GENERAL 3501.1 Scope. The storage and use of flammable gases shall be in accordance with this chapter. Compressed gases shall also

More information

Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions

Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions 1 Scope This standard specifies the requirements and acceptance criteria (100 ppmv) for fugitive emission type testing

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) TEE (HOT TAPPING MATERIAL) S-04-02-040 Page 1 of 7 1.0 SCOPE This specification covers the basic requirements for the design, manufacture and supply

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

NORSOK STANDARD SYSTEM REQUIREMENTS BOP, DIVERTER AND DRILLING RISER SYSTEM (SYSTEM NO.: 12-30, 12-40)

NORSOK STANDARD SYSTEM REQUIREMENTS BOP, DIVERTER AND DRILLING RISER SYSTEM (SYSTEM NO.: 12-30, 12-40) NORSOK STANDARD SYSTEM REQUIREMENTS BOP, DIVERTER AND DRILLING RISER SYSTEM (SYSTEM NO.: 12-30, 12-40) Rev.1, Dec. 1994 CONTENTS 1 FOREWORD 2 2 SCOPE 2 3 NORMATIVE REFERENCES 2 4 DEFINITIONS AND ABBREVIATIONS

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

SOP GEN-007X Crane and Winch Operations

SOP GEN-007X Crane and Winch Operations Page 1 of 7 SOP GEN-007X 1.0 Introduction 2.0 Responsibility 3.0 References 4.0 Training and Qualifications 5.0 Operational Inspections 6.0 Maintenance and Load Tests 7.0 Cranes 8.0 Winches 9.0 Mobile

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Standard Operating Procedures

Standard Operating Procedures Standard Operating Procedures GlassBore and GlassLine EUE 8RD Tubular Goods Composite Lining Systems Focus on Safety and Quality COMPOSITE LINING SYSTEMS Table of Contents Section 1 page 3 Arrival on Production

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual 10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

Flexible Metal Hose Products

Flexible Metal Hose Products Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) Page 1 of 10 CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) 1. SCOPE 1.1 To provide definitive requirements for HIGH PRESSURE PNEUMATIC testing of piping systems according to ASME B31.3. This

More information

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

CLIENT NAME: LOCATION: CALM BUOY INSPECTION: INSPECTOR REVIEWED INSPECTION OF CALM BUOY OVERALL PHOTO REVISION DESCRIPTION: Preliminary / Final Page: 1 TABLE OF CONTENT 1. MANAGEMENT SUMMARY... 3 1.1. SCOPE OF WORK:... 3 1.2. CORRECTIVE ACTIONS...

More information

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS Page 1 of 5 GUIDELINES FOR CONDUCTING 1. Definition of Hydrogenation and Hydrogenolysis Reactions Hydrogenation reactions are synthetic transformations involving hydrogen, metallic catalysts (such as nickel,

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR WATER HEATER SUPPLY SHUTOFF VALVE WITH A / THERMAL EXPANSION CONTROL VALVE IGC 128-2006a8 1. PURPOSE 1.1 The purpose

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

On-Off Connector Skirt

On-Off Connector Skirt On-Off Connector Skirt Retrievable Packers & Accessories The On-Off Connector Skirt is compact, reliable, fully sealing, J-type tubing disconnect device that automatically engages and releases with a small

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

HYDROSTATIC LEAK TEST PROCEDURE

HYDROSTATIC LEAK TEST PROCEDURE This information is proprietary and shall not be disclosed outside your organization, nor shall it be duplicated, used or disclosed for purposes other than as permitted under the agreement with Kinetics

More information

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 6250250/1 IM-P625-03 ST Issue 1 USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 1. General safety information 2. General product information

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

PRESSURIZED EQUIPMENT AND SYSTEMS

PRESSURIZED EQUIPMENT AND SYSTEMS SECTION 20 PRESSURIZED EQUIPMENT AND SYSTEMS 20.A GENERAL 20.A.01 Inspections and tests - general. a. Pressurized equipment and systems shall be inspected and performance tested before being placed in

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information

MSC Guidelines for Independent Fuel Tanks

MSC Guidelines for Independent Fuel Tanks References: Contact Information a. 46 CFR 58.50 (Independent Fuel Tanks) b. 46 CFR 119.440 (Independent Fuel Tanks) c. 46 CFR 182.440 (Independent Fuel Tanks) C. J. Robuck, LCDR, Chief, Engineering Division

More information

PIP PNE00012 Piping Examination and Leak Test Guide

PIP PNE00012 Piping Examination and Leak Test Guide October 2017 Piping PIP PNE00012 Piping Examination and Leak Test Guide PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Types 95L and 95H Pressure Regulators

Types 95L and 95H Pressure Regulators Instruction Manual Form 1151 Types 95L and 95H July 1990 Types 95L and 95H Pressure Regulators W1888 W1888 W5652 Figure 1. NPT Body (Left), NPT Body (Middle), and Flanged Body (Right) Pressure Regulators

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Specifications For Threaded and Butt Weld Hammer Unions

Specifications For Threaded and Butt Weld Hammer Unions .02 Introduction Pacific Hoseflex offers a comprehensive range of standard and sour gas. Each union is thoroughly inspected to ensure long, dependable service in the most extreme conditions. - Three lug

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

SECTION DOMESTIC WATER PIPING

SECTION DOMESTIC WATER PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections

More information

CHE Well Testing Package/Service:

CHE Well Testing Package/Service: CHE Well Testing Package/Service: CHE delivers well testing package And services, trailer mounted well testing package and offshore/onshore well testing services with over 10 years experience. Our testing

More information

INTERLOCKED METAL HOSE

INTERLOCKED METAL HOSE INTERLOCKED METAL HOSE HOSE FUNDAMENTALS Penflex interlocked metal hoses are made for a variety of specialized industrial applications and are available in a wide range of metals, styles and sizes. Interlocked

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HOSE/UMBILICAL CUTTER HCV100 PRODUCT CODE No. 980292 INSTRUCTIONS

More information

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General...

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General... American Petroleum Institute Contents Page 1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General... 7 Apparatus and Materials... 8 High-temperature/high-pressure

More information

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE

More information

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1 Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1 Page 16, Section 4.6, delete the entire section and renumber all subsequent

More information

INSTRUCTIONS FOR THE USE OF ROTARY DRILLING, VIBRATOR AND CEMENT HOSES

INSTRUCTIONS FOR THE USE OF ROTARY DRILLING, VIBRATOR AND CEMENT HOSES ContiTech Rubber Industrial Kft. Hose Technical Department HANDLING Page: 1/9 Date: 31.07.2008 Invalidate the document TKO AS3 rev.4 INSTRUCTIONS FOR THE USE OF ROTARY DRILLING, VIBRATOR AND CEMENT HOSES

More information

RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS

RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER 0400-52-06 DRILLING WELLS TABLE OF CONTENTS 0400-52-06-.01 Drilling Equipment 0400-52-06-.03 Casingheads 0400-52-06-.02 Blowout Prevention

More information

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5 operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions

More information

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE Government of Bermuda Department of Maritime Administration 2015 027 BERMUDA SHIPPING NOTICE Maintenance and Inspection of Fixed Carbon Dioxide Fire Extinguishing Systems Ref: SOLAS 74/88 as amended, Regulation

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents Owner: HSE Performance Assurance ALL HSE PRC 172 Approved By: Manager, HSE Performance Assurance Retention Code: CG01 CA Revised: March 2015 Review Frequency: Five years or less Table of Contents 1.0 Purpose...

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

MSC Guidelines for Pressure Vessels

MSC Guidelines for Pressure Vessels References: a. 46 CFR Part 54 Pressure Vessels S. T. Brady, CDR, Chief, Engineering Division b. ASME Boiler and Pressure Vessel Code (BPVC), Section VIII, Division 1, (1998 Edition) c. Navigation and Inspection

More information

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Features General application The RP03 provides protection from both backsiphonage and backpressure

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems Section: Page 20.A General... 20-1 20.B Compressed Air and Gas Systems... 20-4 20.C Boilers and Systems... 20-7 20.D Compressed Gas Cylinders...

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

MSC Guidelines for Engine Cooling Systems

MSC Guidelines for Engine Cooling Systems S. T. Brady, CDR, Chief, Engineering Division References: Contact Information: a. 46 CFR 56.60, 56.50-95 & 56.50-96 (Subchapter F) b. 46 CFR 77.03-1 (Subchapter H) c. 46 CFR 90.20 & 46 CFR 96.03 (Subchapter

More information

Hose Reel Unit, OMM. Discipline: TECHNIC Configuration control: X. Rev. Purpose Date Prep. Check. Appr. Changeorder No.

Hose Reel Unit, OMM. Discipline: TECHNIC Configuration control: X. Rev. Purpose Date Prep. Check. Appr. Changeorder No. OPERATION AND MAINTENANCE MANUAL Doc.No.: Hose Reel Unit, OMM Discipline: TECHNIC Configuration control: X Yes No Access: KOS Rev. Purpose Date Prep. Check. Appr. Changeorder No. 02 AS BUILT 111298 ID

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors 1130050/4 IM-P113-02 ST Issue 4 UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

Guide for Evaluating Your Hose Assembly Supplier

Guide for Evaluating Your Hose Assembly Supplier Guide for Evaluating Your Hose Assembly Supplier Supplier Evaluation Checklist, and How to Clearly Define Application Requirements Safe, reliable hose assemblies require appropriate specification work

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

Technical Diving Equipment

Technical Diving Equipment POMMEC LARS SYSTEM EASILY CONVERTED TO WET BELL SYSTEM POMMEC 2 DIVER LAUNCH AND RECOVERY SYSTEM WITH DIVING BASKET This Launch and Recovery System is specifically designed to provide a compact option

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

THE PROCESS OF JOINT INTEGRITY

THE PROCESS OF JOINT INTEGRITY BOLTED JOINTS A.333 THE PROCESS OF JOINT INTEGRITY To assist in managing a process, ask yourself the following questions: why, what, who, and how? Why do we need a Flange Joint Integrity program? This

More information

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company TRI LOK TRI LOK TRIPLE OFFSET BUTTERFLY VALVE SAFETY MANUAL The High Performance Company Table of Contents 1.0 Introduction...1 1.1 Terms and Abbreviations... 1 1.2 Acronyms... 1 1.3 Product Support...

More information