1 UP P n e u m a t i c ModelsEZU-15 & EZU-15-R BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

2 Table of Contents GETTING STARTED INSPECTION SAFETY DEFINITIONS SAFETY INSTRUCTIONS SAFETY WARNING LABEL LOCATIONS RESPONSIBILITIES OF OWNERS/USERS SPECIFICATIONS RECOMMENDED FLOOR AREA FUNCTIONAL DESCRIPTION SCISSOR BLOCKING INSTRUCTIONS INSTALLATION TECHNICAL SPECIFICATIONS & PERFORMANCE OPERATING INSTRUCTIONS HANDLING INSTRUCTIONS PORTABILITY INSTRUCTIONS ROUTINE MAINTENANCE REPLACEMENT PARTS EZU-15-R EXPLODED VIEW EZU-15-R PARTS LIST EZU-15 EXPLODED VIEW EZU-15 PARTS LIST PORTABILITY PORTABILITY PARTS LIST List of Figures Figure 1 - Safety Warning Label Locations Figure 2 - EZU-15 Specification Drawing Figure 3 - EZU-15-R Specification Drawing

3 Figure 4 - Recommended Floor Area Figure 5 - Maintenance Bar Operation Figure 6 - Pneumatic Components Figure 7 - Handling the EZ Up Lift Table Figure 8 - Lift Height vs Air Pressure Diagram Figure 9 - Control Lever Figure 10 - Portability Description Figure 11 - Portability Wheel Engagement Figure 12 - Portability Wheel Disengagement Figure 13 - Fitting Disassembly Figure 14 - EZ Up Pneumatic Schematic Figure 15 - EZU-15-R Exploded View Figure 16 - EZU-15 Exploded View Figure 17 - Portability Illustration List of Tables Table 1 - EZ Up Performance Date Placed in Service Serial Number Dealer

4 GETTING STARTED PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE EZ UP PNEUMATIC LIFT TABLE. The safety of all persons installing, using or servicing the EZ Up lift table is of utmost importance to Bishamon. The EZ Up is capable of supporting heavy loads and is capable of causing SEVERE PERSONAL INJURY if used improperly or certain safety precautions are not taken. When properly used and maintained, the EZ Up will provide many years of safe, trouble free service. If you have any questions about any of the instructions in this manual or about the use of this product, PLEASE contact your DEALER or Bishamon Industries Corporation. EZ Up is a trademark of Bishamon Industries Corporation. Throughout this service manual the EZ Up pneumatic lift table may be referred to as the lift table or the lift. INSPECTION IMMEDIATELY upon receipt of the EZ Up lift table, remove all packing and strapping material and visually inspect the unit for damage. Any damage to the lift MUST BE NOTED on the delivery receipt. After the preliminary inspection is conducted, the lift should be thoroughly inspected for any concealed damage that was not readily apparent during the preliminary inspection. Any concealed damage found that was not noted on the delivery receipt should be IMMEDIATELY reported in writing TO THE DELIVERING CARRIER. SAFETY DEFINITIONS Bishamon uses the following system to identify the degree of risk associated with hazards and unsafe practices. DANGER - Immediate hazard which will result in SEVERE PERSONAL INJURY or DEATH. WARNING - Hazard or unsafe practice which could result in SEVERE PERSONAL INJURY or DEATH and PROPERTY DAMAGE. CAUTION - Hazard or unsafe practice which could result in MINOR PERSONAL INJURY and PROPERTY DAMAGE. SAFETY INSTRUCTIONS DANGER 1. READ THIS MANUAL COMPLETELY BEFORE USING AND THOROUGHLY UNDERSTAND AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. A falling lift table can cause SEVERE PERSONAL INJURY or DEATH. NEVER go under the platform until the load is removed and the scissor mechanism is blocked with the maintenance bars. 3. The maintenance bars have been designed for use only when the lift is UNLOADED. NEVER place any load on the platform with the maintenance bars engaged. SEVERE PERSONAL INJURY or DEATH and PROPERTY DAMAGE could result. 4. NEVER sit, stand or ride on the platform or rotating surface. Moving components could cause loss of balance. SEVERE PERSONAL INJURY or DEATH could result. 1 EZ UP

5 WARNING 1. The EZ Up pneumatic lift table is designed for use with stable, uniformly distributed loads on a solid level floor. DO NOT concentrate the load at one point on the pallet or platform. ALWAYS uniformly distribute each layer of load over the supporting surface. DO NOT use the EZ Up lift table for any purpose other than its intended use. 2. SHEARING HAZARD. ALWAYS keep hands and feet clear of the scissor mechanism and all moving components. DO NOT put hands under the rotator ring or platform when in use. SEVERE PERSONAL INJURY could result. 3. CRUSHING HAZARD. ALWAYS keep hands and feet clear of all moving components. DO NOT put feet on the base frame when in use. SEVERE PERSONAL INJURY could result. 4. PINCH POINT HAZARD. ALWAYS keep hands and fingers clear of the underside of the rotator ring or platform. SEVERE PERSONAL INJURY could result. 5. SUDDEN MOVEMENT HAZARD. Due to the compressibility of air, use CAUTION when adding or removing load from the platform. Platform movement MAY occur as the load weight changes. SEVERE PERSONAL INJURY could result. 6. DO NOT over pressurize or overload the EZ Up lift table. The maximum system air pressure is 100 psi (6.9 bar). ALWAYS stay within the designated pressure and capacity ratings. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. 7. NEVER leave the loaded lift table unattended unless the platform is in the fully lowered position and the air pressure has been released. 8. ALL lift servicing must be performed by qualified personnel only. Unauthorized modifications to this lift may compromise the performance and safety of the system. UNDER NO CIRCUMSTANCES should you attempt any repair or service that is not covered in this manual or authorized by Bishamon Industries Corporation. 9. The release of air under high pressure can cause SEVERE PERSONAL INJURY. Before servicing the lift, ALWAYS remove the load, engage the maintenance bars and RELEASE THE AIR PRESSURE. 10. The EZ Up lift table is supplied with a remote control valve and has an air line connecting the control valve to the lift. Use CAUTION not to trip over the air line and DO NOT run over the air line with mobile equipment. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. 11. ALWAYS ensure all safety warning labels are in place and legible. If not, remove the lift table from service and replace the required labels. Refer to Figure 1 for label descriptions and locations. 12. DO NOT inflate the air spring when removed from the lift table. Pressurizing the unrestricted air spring may cause assembly to burst. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. CAUTION 1. ALWAYS use clean dry air to pressurize the system. 2. ALWAYS securely anchor the base frame to the floor to ensure maximum stability. 3. The optional Semi-Live Portability is designed for use with an unloaded lift. ALWAYS remove the load before engaging the portability wheels. NEVER apply load with the portability wheels engaged. EZ UP 2

6 1. READ THE MANUAL COMPLETELY BEFORE USING AND THOROUGHLY UNDERSTAND AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. A falling lift table can cause SEVERE PERSONAL INJURY or DEATH. NEVER go under the platform until the load is removed and the scissor mechanism is secured in the raised position with the maintenance devices. 3. The maintenance devices have been designed for use only when the lift is UNLOADED. NEVER place any load on the platform with the maintenance devices engaged. SEVERE PERSONAL INJURY or DEATH and PROPERTY DAMAGE could result. 4. NEVER sit, stand or ride on the platform. Moving components could cause loss of balance. SEVERE PERSONAL INJURY or DEATH READ MANUAL SHEAR HAZARD NO RIDING could result. CRUSH HAZARD KEEP CLEAR USE MAINTENANCE DEVICES MEC\B The EZ Up pneumatic lift table is designed for use with stable, uniformly distributed loads on a solid level floor. DO NOT concentrate the load at one point on the pallet or platform. ALWAYS uniformly distribute each layer of load over the supporting surface. DO NOT use the EZ Up lift table for any purpose other than its intended use. 2. SHEARING HAZARD. ALWAYS keep hands and feet clear of the scissor mechanism and all moving components. DO NOT put hands under the rotator ring or platform when in use. SEVERE PERSONAL INJURY could result. 3. CRUSHING HAZARD. ALWAYS keep hands and feet clear of all moving components. DO NOT put feet on the base frame when in use. SEVERE PERSONAL INJURY could result. 4. PINCH POINT HAZARD. ALWAYS keep hands and fingers clear of the underside of the rotator ring or platform. SEVERE PERSONAL INJURY could result. 5. SUDDEN MOVEMENT HAZARD. Due to the compressibility of air, use CAUTION when adding or removing load from the platform. Platform movement WILL occur as the load weight changes. SEVERE PERSONAL INJURY could result. 6. DO NOT overpressurize or overload the EZ Up lift table. The maximum system air pressure is 100 psi (6.9 bar). ALWAYS stay within the designated pressure and capacity ratings. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. 7. NEVER leave the loaded lift table unattended unless the platform is in the fully lowered position and the air pressure has been released. 8. ALL lift servicing must be performed by qualified personnel only. Unauthorized modifications to this lift may compromise the performance and safety of the system. UNDER NO CIRCUMSTANCES should you attempt any repair or service that is not covered in this manual. 9. The release of air under high pressure can cause SEVERE PERSONAL INJURY. Before servicing the lift, ALWAYS remove the load, engage the maintenance bars and RELEASE THE AIR PRESSURE. 10. The EZ Up lift table is supplied with a remote control valve and has an air line connecting the control valve to the lift. Use CAUTION not to trip over the air line and DO NOT run over the air line with mobile equipment. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. 11. ALWAYS ensure all safety warning labels are in place and legible. If not, remove the lift table from service and replace the required labels. Refer to Figure 1 for label descriptions and locations. 12. DO NOT inflate the air spring when removed from the lift table. Pressurizing the unrestricted air spring may cause assembly to burst. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. 1. ALWAYS use clean dry air to pressurize the system. 2. ALWAYS securely anchor the base frame to the floor to ensure maximum stability. 3. The optional Semi-Live Portability is designed for use with an unloaded lift. ALWAYS remove the load before engaging the portability wheels. NEVER apply load with the portability wheels engaged. SAFETY WARNING LABEL LOCATIONS MAXIMUM CAPACITY 1500 lb ( psi (5.5 bar) 2000 lb ( psi (6.2 bar) Options and accessories may affect lift capacity MEC\B DANGER WARNING CAUTION NEVER GO UNDER THE PLATFORM UNTIL THE LOAD IS REMOVED AND THE SCISSOR MECHANISM IS BLOCKED. Note: EZU-15 decals shown for reference only. Figure 1 - Safety Warning Label Locations RESPONSIBILITIES OF OWNERS/USERS It is the responsibility of the Owners/Users to: 1. Advise the DEALER or Bishamon Industries Corporation when deflection or creep is critical to the application. 2. Ensure the lift is inspected and maintained in proper working order in accordance with the operation/maintenance instructions provided in this manual. 3. Ensure any lift not in safe operating condition such as, but not limited to excessive air leakage, missing rollers, pins or fasteners, bent or cracked structural members, cut or frayed air lines, damaged or malfunctioning controls or safety devices, etc. shall be removed from service until it is repaired to Bishamon s standards. 4. Ensure all repairs are made by qualified personnel in conformance with the instructions provided by Bishamon Industries Corporation. 5. Ensure only trained and authorized personnel are permitted to operate the lift and that all operators understand the operating instructions, safety rules and hazards associated with this lift. 6. Ensure the lift is used in accordance with the guidelines provided in this manual. 7. Ensure modifications or alterations of any lift are made only with the written permission of Bishamon Industries Corporation. 3 EZ UP

7 SPECIFICATIONS SPECIFICATIONS: EZU MAXIMUM CAPACITY lb ( psi (6.2 bar) lb ( psi (5.5 bar) 30 in. (762 mm) 2. COLLAPSED HEIGHT in (222 mm) 3. EXTENDED HEIGHT - 30 in (762 mm) 4. WEIGHT -500 lb (227 kg) 5. AIR REQUIREMENTS - See Table 1 6. MAXIMUM AIR PRESSURE psi (6.9 bar) 7. RELIEF VALVE SETTING psi (7.6 bar) 8. AIR SPRING - Two Ply Fabric Reinforced Rubber. 9. SOUND PRESSURE LEVEL - <70 db(a) 10. OPERATING ENVIRONMENT - Indoors 11. LIGHTING REQUIREMENT - Good General Lighting 12. OPERATING ENVIRONMENT TEMPERATURE to +120 F (-1.1 C to 48.9 C) 51 in. (1295 mm) 50 1/2 in. (1283 mm) 8 3/4 in. (222 mm) COLLAPSED HT. 30 in. (762 mm) 30 in (762 mm) EXTENDED HT. Figure 2 - EZU-15 Specification Drawing EZ UP 4

8 SPECIFICATIONS CONT. SPECIFICATIONS: EZU-15-R 1. MAXIMUM CAPACITY lb ( psi (6.2 bar) lb ( psi (5.5 bar) 2. COLLAPSED HEIGHT in (225 mm) 30 in. (762 mm) 3. EXTENDED HEIGHT in (765 mm) 4. WEIGHT lb (205 kg) 5. AIR REQUIREMENTS - See Table 1 6. MAXIMUM AIR PRESSURE psi (6.9 bar) 7. RELIEF VALVE SETTING psi (7.6 bar) 8. AIR SPRING - Two Ply Fabric Reinforced Rubber. 9. SOUND PRESSURE LEVEL - <70 db(a) 10. OPERATING ENVIRONMENT - Indoors 11. LIGHTING REQUIREMENT - Good General Lighting 12. OPERATING ENVIRONMENT TEMPERATURE to +120 F (-1.1 C to 48.9 C) 50 1/2 in. (1283 mm) 8 7/8 in. (225 mm) COLLAPSED HT. Ø43 in. (Ø1092 mm) 30 1/8 in. (765 mm) EXTENDED HT. Figure 3 - EZU-15-R Specification Drawing 5 EZ UP

9 RECOMMENDED FLOOR AREA 39 in (1 meter) OPERATING ZONE 39 in (1 meter) DANGER ZONE 39 in (1 meter) 39 in (1 meter) OPERATING ZONE 39 in (1 meter) DANGER ZONE 39 in (1 meter) 39 in (1 meter) 39 in (1 meter) Figure 4 - Recommended Floor Area The lift table s recommended floor area, shown in Figure 4, identifies the Danger Zone and the Operating Zone. The Danger Zone is the area inside the base frame and under the platform structure. The recommended Operating Zone is a distance of 39 inches (1 meter) extending beyond the danger zone on all sides. EZ UP 6

10 FUNCTIONAL DESCRIPTION The EZ Up pneumatic lift tables are designed to position a pallet, container or work in progress at a convenient working height. Positioning the load at a convenient height provides the operator with easier access to components and minimizes bending, reaching and stretching. EZ Up tables provide an economical alternative to hydraulic lifts and eliminating the need for hydraulic pumps and cylinders. Load support is provided by a single Firestone Airstroke Actuator positioned between the scissor structure and the platform. The actuator provides the EZ Up lift table with a maximum capacity of 2000 lb at 90 psi. As detailed in the technical specifications, capacity and speed are determined by the air pressure and flow available. Raising and lowering is controlled by a remote mounted, lever actuated, pneumatic valve. For operator safety, the hand lever is spring centered and will return to the neutral position when released. SCISSOR BLOCKING INSTRUCTIONS To Engage The Maintenance Bars 1. Remove all load from the platform and raise the lift table to its fully raised position. 2. As detailed in Figure 5, rotate BOTH maintenance bars approximately 90º such that the bars are parallel with the scissor legs. The end of the bar should be positioned between the end of the leg and the collar on the roller shaft. 3. Lower the lift by shifting the hand control lever to the Lower position and allow the scissor mechanism to rest against the maintenance bars. ALWAYS check the position of both maintenance bars before going under the platform.. NEVER GO UNDER THE PLATFORM UNTIL THE LOAD IS REMOVED AND THE SCISSOR MECHANISM IS BLOCKED. Figure 5 - Maintenance Bar Operation To Disengage The Maintenance Bars 4. Raise the platform to its fully raised position by shifting the hand control lever to the Raise position. 5. Rotate both maintenance bars approximately 90º to their original position. DANGER A falling lift table can cause SEVERE PERSONAL INJURY or DEATH. NEVER go under the platform until the load is removed and the scissor mechanism is blocked with the maintenance bars. The maintenance bars have been designed for use only when the lift is UNLOADED. NEVER place any load on the platform with the maintenance bars engaged. SEVERE PERSONAL INJURY or DEATH and PROPERTY DAMAGE could result. 7 EZ UP

11 INSTALLATION Installation of the EZ Up lift table is a simple process; however, certain precautions must be taken to ensure years of trouble free service. The EZ Up requires clean, dry, compressed air to operate properly. A filter and regulator with a pressure gauge should be installed on an air line in the installation area before initially charging the system for use. Before you begin, locate and identify the pneumatic components detailed in Figure 6. These components will be referred to in the Installation and the Set-Up procedures. Make sure you understand the function of each component before proceeding. Control Valve Bleed Control Valve 3/8" Male Pipe Swivel Inlet 3/8" NPT Air Line Figure 6 - Pneumatic Components INSTALLATION INSTRUCTIONS Air Line - A ten (10) ft long pnuematic air line is supplied with the EZ Up lift table. One end of the air line is connected to the lift at the factory. The other end of the air line is supplied with a 3/8 in. male pipe thread swivel and must be attached to the control valve. Control Valve - A three (3) way, three (3) position pneumatic valve is supplied with the EZ Up lift table. The valve has a spring centered hand lever so that when the lever is released from the Raise or Lower positions it will automatically return to the neutral position. The valve is supplied with 3/8 in. female pipe threads. Bleed Control Valve - The bleed valve is an adjustable one way valve screwed into the exhaust port of the control valve. The valve provides lowering speed control by regulating the rate of discharge air from the air spring. Turning the valve counter-clockwise opens the valve and increases the lowering speed of the lift. Likewise, turning the valve clockwise closes the valve and reduces the lowering speed. EZ UP 8

12 1. Make sure the installation area is clean before starting. Check the installation surface to ensure it is relatively smooth and level. Otherwise, the lift s base frame should be shimmed to make it level. 2. Using a forklift or similar equipment, move the palletized lift table to the location it is to be installed. 3. Remove the steel bands securing the lift table to the pallet. Next, remove all packing material and place it off to the side. Figure 7 - Handling the EZ Up Lift Table 4. Using a forklift, carefully position the forks under the platform structure, as detailed in Figure 7. Slowly lift the platform to fully extend the lift, then lift the unit off the pallet. Next, remove the pallet and place if off to the side. Then position the lift table in the desired location. Use care not to damage or run over the air line supplied with the lift. 5. Mount the control valve supplied with the lift table in a location convenient to the operator. The valve should be positioned so that unintentional operation is avoided. Ensure the air line will reach the valve position and is not in a walkway or obstructing forklift traffic. 6. Connect the lift s air line to the control valve. A 3/8 in. pipe thread elbow is provided at the valve s outlet port. Depending on the valve s mounting position, the air line may be connected to the elbow or the elbow removed and the line connected directly to the valve body. 7. Shut off the air supply and connect the air line from the regulator to the inlet of the control valve. Open the air supply and set the regulator to the desired operating pressure (see Table 1). The maximum operating pressure is 100 psi. Bishamon recommeds securing the EZ Up lift table to the floor for maximum stability. However, in most applications, floor anchors are not required for safe operation. Contact your Dealer or Bishamon Industries Corporation if you have any questions regarding the proper installation of the lift. Complete steps 8 and 9 to secure the lift to the floor. 8. The base frame of the lift table has 4 pre-drilled holes for lagging the unit securely to the floor. Using the 4 holes as a template, mark the holes on the floor. Using the forklift, shift the position of the lift to allow room for drilling, then drill. When complete, reposition the lift and install anchors lagging the EZ Up lift securely to the floor. NOTE: Make sure the bottom surfaces of the base are fully supported along the width with shims or concrete grout. 9. The lift is now ready for operation. Refer to the Technical Specifications and Performance section to determine the air pressure and flow requirements. 9 EZ UP

13 TECHNICAL SPECIFICATIONS & PERFORMANCE The lift capacity, raised height and speed of the EZ Up lift table depend on the system pressure (PSI) and the system flow (SCFM). Lift capacity and raised height depend on the system pressure alone. The effective area of an airspring decreases with height. Therefore, pnuematic lifts, which use air springs for load support, will generally lift more capacity initially. The effective lift capacity then decreases as the height of the spring increases. This is illustrated in Figure 8, which shows the height a 1500 lb and a 2000 lb load can be lifted at various air pressures. The air pressures and lift capacities listed in Table 1 are the pressures required to lift the stated capacities to the maximum height. The maximum operating pressure is 100 PSI. On the other hand, lift speed depends on SCFM, which is a function of air compressor capacity. Many factors, such as differential pressure, pipe sizes, etc., affect the air flow in a system. A system capable of delivering a minimum of 20 SCFM will provide acceptable performance. Generally, increasing the SCFM will increase the lift speed, whereas increasing the pressure will increase the capacity and may increase the lift speed. Approximate lift and lower speeds are also listed in Table (762) PLATFORM HEIGHT in. (mm) 20 (508) 10 (254) 1500 lb 2000 lb 0 50 (3.4) 60 (4.1) 70 (4.8) 80 (5.5) 90 (6.2) 100 (6.9) AIR PRESSURE psi (bar) Figure 8 - Lift Height vs Air Pressure Diagram EZ UP 10

14 Load (lb) Pressure (psi) Raised Height (in.) Approximate Raise Time (Sec) Approximate Lowering Time (Sec) OPERATING INSTRUCTIONS Table 1 - EZ Up Performance Raising the Platform 1. Before raising the platform, BE SURE that all others are well clear of the lift. If the platform is loaded, RECHECK the position and condition of the load. 2. Shift the hand lever to the Raise position (see Figure 9) to charge the system with air and raise the platform to a convenient working height. CONTINUOUSLY WATCH the condition of the load as the platform is raised. If the load appears to be shifting, STOP, lower the platform and adjust the load. RAISE LOWER Loading / Unloading the Platform 1. Check the load or component weight to ensure the total load does not exceed the capacity of the lift. Refer to the capacity decal on the end of the platform. 2. Raise the platform to a convenient working height. Figure 9 - Control Lever 3. Uniformly distribute the load over the platform or supporting surface and ensure the load is tightly stacked. Use CAUTION when adding or removing load from the platform. Due to the compressibility of air the platform may move down or up when adding or removing load. WARNING ALWAYS uniformly distribute each layer of load over the supporting surface. DO NOT concentrate the load at one point on the platform or pallet. DO NOT overpressurize or overload the EZ Up lift table. The maximum system air pressure is 100 psi (6.9 bar). ALWAYS stay within the designated pressure and capacity ratings. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. SUDDEN MOVEMENT HAZARD. Due to the compressibility of air, use CAUTION when adding or removing load from the platform. Platform movement MAY occur as the load weight changes. SEVERE PERSONAL INJURY could result. 11 EZ UP

15 Lowering the Platform 1. Before lowering the platform, BE SURE that all others are well clear of the lift. If the platform is loaded, RECHECK the position and condition of the load. 2. Shift the hand lever to the Lower position (see Figure 9) to discharge the air and lower the platform. CONTINUOUSLY WATCH the condition of the load as the platform is lowering. If the load appears to be shifting, STOP and adjust the load. HANDLING INSTRUCTIONS Bishamon recommends securing the EZ Up lift table to the floor for maximum stability. However certain applications require the lift table to be relocated frequently. Handling the EZ Up can be easily accomplished as follows: 1. Remove all load from the platform and raise the lift table to its fully raised position. 2. Using a forklift, position the forks under the platform structure, as detailed in Figure Slowly lift the EZ Up until the base frame clears the floor. The lift table can now be moved to the next location. PORTABILITY INSTRUCTIONS CATCH LIP DOLLY HANDLE LOAD WHEEL STOP ARM HITCH PLATE DOLLY TONGUE Figure 10 - Portability Description TO ENGAGE THE PORTABILITY WHEELS: 1. Position dolly tongue under the base lift plate, as shown in Figure 11, Section Slowly raise the lift table base frame by rotating the handle until the stop arm clears the catch lip, as detailed in Figure 11, Sections 2 and Lower the base until the stop arm completely engages the catch, as shown in Figure 11, Section Position the dolly under the hitch plate at the opposite end of the base frame. Be sure that the dolly pin completely engages the hole in the hitch plate. 5. Complete the engagement by rotating the handle to lift the base frame clear of the floor. 6. This type of portability is designed for PULLING the EZ Up lift table. Use caution when pushing. EZ UP 12

16 TO DISENGAGE PORTABILITY WHEELS: Figure 11 - Portability Wheel Engagement 7. Lower the base frame and remove the dolly from the hitch plate. 8. Reposition the dolly tongue under the base lift plate, as detailed in Figure 12, Section Slowly raise the base frame until the stop arm falls backwards, as shown in Figure 12, Sections 6 and Lower slowly until the base frame sets completely on the floor, as shown in Figure 12, Section ROUTINE MAINTENANCE Figure 12 - Portability Wheel Disengagement The EZ Up lift table is designed to provide years of trouble free service and requires very little maintenance. However, a routine inspection and maintenance program will prevent costly replacement of parts and/or downtime. All service should be performed by a qualified service person who has an understanding of lift equipment and pneumatic diagrams. This person should be thoroughly familiar with the operation and use of this type of equipment. 13 EZ UP

17 Daily Inspection DANGER A falling lift table can cause SEVERE PERSONAL INJURY or DEATH. NEVER go under the platform until the load is removed and the scissor mechanism is secured in the raised position with the maintenance bars. The maintenance bars have been designed for use only when the lift is UNLOADED. NEVER place any load on the platform with the maintenance catches engaged. SEVERE PERSONAL INJURY or DEATH and PROPERTY DAMAGE could result. 1. Before use, visually inspect the lift for worn, damaged or broken components. If any of these conditions exist, REMOVE the lift from service and contact a qualified service person. 2. Raise the platform and visually inspect the pneumatic components (i.e. hose, tubing, fittings and airspring) for damage or wear. If any of these conditions exist, REMOVE the lift from service and contact a qualified service person. 3. Check the condition of the warning labels. The warning labels are for the safety of the operator. If the labels are worn, missing or unreadable, REPLACE them before placing the lift back in service. Monthly Inspection and Maintenance 1. Inspect snap rings and roll pins at all pivot shaft and axle locations. If not in place and/or secure, replace or repair at once. 2. Inspect all rollers for signs of wear. Replace as necessary. Rollers and axles have lifetime lubricated bushings; therefore, they do not need grease or lubrication. 3. Inspect the air spring retaining screws for tightness. Tighten if necessary. 4. If the lift table is equipped with a rotating platform, inspect the center pivot bearing and the support bearings for ease of operation. Replace if necessary. 5. Should removal of the air lines be required, mark the initial position before removing the fitting nut. When reinstalling, first tighten the nut by hand, then using a wrench rotate the nut to the original position. Tighten the nut an additional 1/8 turn. Do not over tighten as air leakage may occur. 6. Inspect the air line and tubing for chaffing and signs of wear. If worn, replace at once. 7. Inspect the air line connections for tightness. Tighten if necessary. Figure 13 - Fitting Disassembly EZ UP 14

18 Monthly lubrication should consist of the following: 1. For EZ Up lift tables equipped with the optional semi-live portability, lubricate the stop arm assembly and the wheel arm assembly with silicon spray to ensure ease of movement. REPLACEMENT PARTS WARNING DO NOT inflate the air spring when removed from the lift table. Pressurizing the unrestricted air spring may cause assembly to burst. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result. Bishamon has carefully selected the components used in the manufacture of the EZ Up lift tables. In PRESSURE RELIEF VALVE FACTORY SET LEVER ACTUATED CONTROL VALVE 3/8" AIR LINE BLEED CONTROL 3/8" AIR LINE (PROVIDED BY OTHERS) 3/8" NPT INLET PORT AT CONTROL VALVE AIRSPRING the event replacement parts are required, ALWAYS use genuine EZ Up components provided by Bishamon. These parts can be obtained from your Bishamon DEALER or by contacting Bishamon Industries Corp. PORTABILITY Figure 14 - EZ Up Pneumatic Schematic 15 EZ UP

EZ LOADER AUTOMATIC PALLET POSITIONER. United States Patent USA European Patent United Kingdom France Germany Other Patents Pending

EZ LOADER AUTOMATIC PALLET POSITIONER. United States Patent USA European Patent United Kingdom France Germany Other Patents Pending EZ LOADER AUTOMATIC PALLET POSITIONER United States Patent 5299906 USA European Patent 0512775 United Kingdom France Germany Other Patents Pending Date Placed in Service: Serial Number: Dealer: Version

More information

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 405-282-8105 www.autoquip.com Item # 830ABS Version 1.0 07/2001

More information

Roto-Max Work Positioner. Operation. Maintenance

Roto-Max Work Positioner. Operation. Maintenance Roto-Max Work Positioner Operation Maintenance Lift Products Inc. P.O Box 349 Elm Grove Wisconsin 53122-0349 PH: 877-543-8776 FX: 262-521-5725 Manual #19950 1 WARNING Do not operated this lift table unless

More information

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No Operator s Manual with Maintenance Schedule Fourth Edition Second Printing Part No. 82297 Operator s Manual Fourth Edition Second Printing Important Read, understand and obey these safety rules and operating

More information

HYDRAULIC PALLET TRUCKS. MODEL Nos: PT550BC, PT685BC, PT550NC, PT685NC OPERATION & MAINTENANCE INSTRUCTIONS

HYDRAULIC PALLET TRUCKS. MODEL Nos: PT550BC, PT685BC, PT550NC, PT685NC OPERATION & MAINTENANCE INSTRUCTIONS HYDRAULIC PALLET TRUCKS MODEL Nos: PT550BC, PT685BC, PT550NC, PT685NC OPERATION & MAINTENANCE INSTRUCTIONS 0711 WARNING! PT550NC MAXIMUM LOAD - 2000KG PT685NC MAXIMUM LOAD - 2000KG PT550BC MAXIMUM LOAD

More information

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY OWNER S MANUAL This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY Models covered; PA506 EL506 Ergonomic Tool Arms, LLC PO Box

More information

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to

More information

HYDRAULIC MOBILE LIFTING TABLE

HYDRAULIC MOBILE LIFTING TABLE HYDRAULIC MOBILE LIFTING TABLE MODEL NO: HTL300 & HTL500 PART NO: 7610148 & 76210152 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1116 INTRODUCTION Thank you for purchasing this CLARKE

More information

Operator s Manual Series 2400 Material Lift

Operator s Manual Series 2400 Material Lift October 2013 Operator s Manual Series 2400 Material Lift USA 7514 Alabonson Rd. Houston, TX 77088 ph: 281-999-6900 fax: 281-999-6966 CANADA 75 Saltsman Drive, Unit 5 Cambridge, Ontario N3H 4R7 ph: 519-653-5300

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG

More information

Owner s Manual Air Bag Lift Tables

Owner s Manual Air Bag Lift Tables Owner s Manual Air Bag Lift Tables Airbag Lift Manual for PPA, GTA, GLSA & GLTA Models SOUTHWORTH PRODUCTS CORP PO Box 1380, Portland, ME 04104-1380 Telephone: 1-800-743-1000 or 207-878-0700 Fax: 207-797-4734

More information

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS SPX Corporation 5885 11th Street Rockford, IL 6119-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (8) 477-8326 Fax: (8) 765-8326 Order Entry: (8) 541-1418 Fax: (8) 288-731 Parts List

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET

More information

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION. GSR500 Ram Assembly General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling

More information

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this

More information

75 Ton SD Shop Press Operating Instructions

75 Ton SD Shop Press Operating Instructions 75 Ton SD Shop Press Operating Instructions MODEL NO. 856SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment OPERATOR S MANUAL FOR MORSE TILT-TO-LOAD DRUM ROTATOR SAFETY INFORMATION: While Morse Manufacturing Co. drum handling equipment is engineered for safety and efficiency, a high degree of responsibility

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel SERVICE BULLETIN SB2023 Rev C 7/11 SIGNATURE DEF REELS Models: 2400-006 Bare Reel 2400-007 16 Reel 2400-008 20 Reel 2400-009 30 Reel Thoroughly read and understand this manual before installing, operating

More information

20 Ton SD Shop Press Operating Instructions

20 Ton SD Shop Press Operating Instructions 20 Ton SD Shop Press Operating Instructions MODEL NO. 850SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential

More information

General Information. NTA607HD Lift Assist Adjustments. Tools Required. Work Location. Notations and Conventions U B F D R B F L

General Information. NTA607HD Lift Assist Adjustments. Tools Required. Work Location. Notations and Conventions U B F D R B F L Great Plains Manufacturing, Inc. 1 NTA607HD Lift Assist Adjustments Null4: When you see this symbol, the subsequent instructions and warnings are serious - follow without exception. Your life and the lives

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

BRONZE BUSHING REPLACEMENT PROCEDURE DN345 & NL450C

BRONZE BUSHING REPLACEMENT PROCEDURE DN345 & NL450C 1 BRONZE BUSHING REPLACEMENT PROCEDURE V.2 12/3/2014 DN345 & NL450C 2 Safety Instructions Removing Walking Beams 3 1. Position spreader on a flat concrete surface capable of supporting weight of spreader

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

PDY TON HYDRAULIC CRIMPING TOOL WARNING

PDY TON HYDRAULIC CRIMPING TOOL WARNING OPERATORS ORS GUIDE PDY-1220 12 TON HYDRAULIC CRIMPING TOOL All information found in this guide must be read and understood before use or testing of this tool. Failure to read and understand these warnings

More information

IMPORTANT: RECEIVING INSTRUCTIONS:

IMPORTANT: RECEIVING INSTRUCTIONS: Instruction Sheet Sidewinder Mechanical Bender IMPORTANT: RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage is found, notify carrier at once.shipping damage

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

750 Cable Cutter INSTRUCTION MANUAL

750 Cable Cutter INSTRUCTION MANUAL INSTRUCTION MANUAL 750 Cable Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL. This manual contains;

TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL. This manual contains; TOOL ARMS with AUTOMATIC DOWN FORCE for LEVER-PERMIT AIR DRIVERS OWNER S MANUAL This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

INSTRUCTION AND PARTS MANUAL MODELS #13000 TO HYDRAULIC CYLINDERS

INSTRUCTION AND PARTS MANUAL MODELS #13000 TO HYDRAULIC CYLINDERS INSTRUCTION AND PARTS MANUAL MODELS #13000 TO 13080 HYDRAULIC CYLINDERS Form No. 102397-AME Operating Instructions for: Single-acting and Double-acting Rams and Cylinders (Various Capacity) DEFINITIONS

More information

Retractable Hose Reel with 3/8" x 50' PVC Hose

Retractable Hose Reel with 3/8 x 50' PVC Hose Retractable Hose Reel with 3/8" x 50' PVC Hose Item# 4816153 Owner s Manual Assembly and Operation Instructions MADE IN CHINA Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before

More information

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD OPERATORS ORS GUIDE REL-510H 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with U style and RELIABLE R12 shell type 12 ton compression dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 92 Steamwhistle

More information

170-SJ Feed UnitTM 470-SJ Feed UnitTM

170-SJ Feed UnitTM 470-SJ Feed UnitTM SPONGE-JET 170-SJ Feed UnitTM 470-SJ Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet 170-SJ / 470-SJ User Manual - REV

More information

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift 2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift CAUTION - PUT SAFETY FIRST 1. Before attempting to install or operate this lift, study and fully understand the proper operating procedures and safety

More information

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

5 Gallon Pressure Pot with HVLP Spray Gun and Hose California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST PARTS BREAKDOWN AND OPERATING MANUAL Copyright 2007, Arcan Professional Tools Rev: 05/15/07 This operating manual contains important safety information. Read

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual OPERATORS ORS GUIDE REL-46 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with RELIABLE R15 and P Style dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 301 Ivyland Road Warminster, PA 18974

More information

PRODUCT OPERATING MANUAL

PRODUCT OPERATING MANUAL PRODUCT OPERATING MANUAL PANBLAST TM AIRSTOP II NPT PNEUMATIC CONTROL HANDLE Manual Number: ZVP PC 0108 00 SECTION 1. GENERAL INFORMATION 2. INTRODUCTION 3. INSTALLATION 4. OPERATING INSTRUCTIONS 5. MAINTENANCE

More information

Operator s Manual. 2010, 2015, 2020, 2025 Material Lifts

Operator s Manual. 2010, 2015, 2020, 2025 Material Lifts July 2017 Operator s Manual 2010, 2015, 2020, 2025 Material Lifts! Before operating this lift, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Call

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

RM051S-XXX-XX SINGLE POST LIFT / RAM

RM051S-XXX-XX SINGLE POST LIFT / RAM OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn 97999-635). INGERSOLL RAND COMPANY LTD 209 NORTH MAIN STREET BRYAN, OHIO 43506 (800)

More information

Operator s Manual. Series 2100 Contractor Lifts

Operator s Manual. Series 2100 Contractor Lifts October 2013 Operator s Manual Series 2100 Contractor Lifts! Before operating this lift, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Call SUMNER

More information

OPERATING INSTRUCTIONS. Parts List N. Note: Owner and operator MUST read and understand this operating instructions before use this lift table.

OPERATING INSTRUCTIONS. Parts List N. Note: Owner and operator MUST read and understand this operating instructions before use this lift table. OPERATING INSTRUCTIONS Parts List 770N te: Owner and operator MUST read and understand this operating instructions before use this lift table. Thank you for using this lift table. Your lift table is made

More information

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 January 2013 Form FVC 084 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.

More information

CUT OFF TOOL MODEL: CAT113

CUT OFF TOOL MODEL: CAT113 CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you

More information

OPERATOR SERVICE MANUAL

OPERATOR SERVICE MANUAL OPERATOR SERVICE MANUAL POSITECH CORPORATION 191 N RUSH LAKE ROAD LAURENS, IA 50554 Phone Number: 800-831-6026 24 Hour Service Phone Number: 541-954-2948 Email: service@positech.com SERIAL NO: RUN NO:

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. y Use only genuine ARO replacement parts to assure compatible. RM051S-XXX-XX Single Post Lift / Ram

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. y Use only genuine ARO replacement parts to assure compatible. RM051S-XXX-XX Single Post Lift / Ram OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn 97999-635). RM051S-XXX-XX RM051S-XXX-XX SINGLE POST LIFT / RAM For use with 5 gallon

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

RT3 CAP NAILER OWNER S MANUAL Operation Safety Maintenance Warranty! www.stingerworld.com PLEASE READ! This manual contains important information about product safety. REV 09/14 WELCOME TO STINGER Congratulations

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

Operation Manual Guillotine Cutter RC-5

Operation Manual Guillotine Cutter RC-5 Operation Manual Guillotine Cutter RC-5 Technical Specifications General Safety/Operating Instructions Using the Guillotine Cutter/Crimper Blade Change Instructions Maintenance Instructions This is a detailed

More information

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL I-867-4T 867-4T Pressure Reducing Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR FUTURE REFERENCE WARNING Read and understand all instructions

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A APCO ARV CLEAN WATER AIR RELEASE VALVES Model 50A Instruction D12013 February 2017 Instructions These instructions provide installation, operation and maintenance information for APCO ARV Clean Water Air

More information

DBML-60/80 Squeeze Tool

DBML-60/80 Squeeze Tool DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs

More information

APP pumps APP and APP Disassembling and assembling

APP pumps APP and APP Disassembling and assembling Service guide APP pumps APP 11-13 and APP 16-22 Disassembling and assembling hpp.danfoss.com Table of Contents Contents 1. Introduction... 2 2. Disassembling the pump... 3 3. Assembling the pump... 6 4.

More information

Operator s Safety Manual Sumner Max Jax / Beam Jax

Operator s Safety Manual Sumner Max Jax / Beam Jax May 2013 Operator s Safety Manual Sumner Max Jax / Beam Jax www.sumner.com 7514 Alabonson Road Houston, TX 77088 U.S.A ph: 281.999.6900 fax: 281.999.6966 75 Saltsman Drive Unit 5 Cambridge, ON N3H 4R7

More information

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual 10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND

More information

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

Shoreline Cantilever Lift 2500lb Capacity Models: (108 inside width) - Part # (120 inside width) - Part # Shoreline Cantilever Lift 2500lb Capacity Models: 25108 (108" inside width) - Part # 1017402 25120 (120" inside width) - Part # 1017403 1. 2. 3. 4. 5. CAUTION - PUT SAFETY FIRST Before attempting to install

More information

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters ADI 3210-A ADI 3210-A Certified ISO 9001 Certified ISO 9001 High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters Warning: An appropriately sized pressure relief device downstream of the regulator

More information

JACK MODULE HYDRAULIC CYLINDERS

JACK MODULE HYDRAULIC CYLINDERS Form No. 102901 Operating Instructions for: JM SERIES High Tonnage Portable Jacks JACK MODULE HYDRAULIC CYLINDERS All cylinders are marked with maximum pressure setting NOTE: For a detailed parts list

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

RM052S-XXX-XX TWO POST LIFT / RAM

RM052S-XXX-XX TWO POST LIFT / RAM OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn 97999-635). INGERSOLL RAND COMPANY LTD 209 NORTH MAIN STREET BRYAN, OHIO 43506 (800)

More information

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. RM052S-XXX-XX Two Post Lift / Ram

SERVICE KITS SPECIFICATIONS GENERAL DESCRIPTION. RM052S-XXX-XX Two Post Lift / Ram OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: S-635 General Information (pn 97999-635). RM052S-XXX-XX RM052S-XXX-XX TWO POST LIFT / RAM For use with 5 gallon /

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As

More information

Types S100K and S102K Pressure Regulators

Types S100K and S102K Pressure Regulators Instruction Manual Form 5624 Types S0K and S2K 01/01 Types S0K and S2K Pressure Regulators W7478-1 Figure 1. Types S0K and S2K Pressure Regulator Introduction Scope of Manual This manual provides instructions

More information

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL GETZ EQUIPMENT INNOVATORS CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL GETZ EQUIPMENT INNOVATORS PEKIN, ILLINOIS, U.S.A. PHONE: (888) 747-4389 FAX: (309) 495-0625 Limited Warranty

More information

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL Introduction Thank you for purchasing a Retracta Auto Rewind Hose Reel. The Retracta range of hose reels are a breakthrough in industrial quality

More information

Installation and Service Manual

Installation and Service Manual An Actuant Company Installation and Service Manual Heavy Duty Hydraulic Stabilization Legs CONTENTS Part # 3010003129 REV 0D Section Page 1.0 Receiving Instructions 2 2.0 Safety Issues 2 3.0 Hydraulic

More information

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information: Hotspotter Model WB-100 Professional Series Assembly, Testing & Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand-Held LP Torches for use with

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180:

SAFETY MEASURES. These important guidelines should always be followed to work safely with the PRIMATECH pneumatic stapler model Q180: PRIMATECH PNEUMATIC 18GA STAPLER Q180 The pneumatic flooring stapler Q180 is a professional precision tool specially developed for the installation of most of 3/8" to 5/8" solid and engineered hardwood

More information

CS150 CAP STAPLER OWNER S MANUAL

CS150 CAP STAPLER OWNER S MANUAL Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Model 420-HY Pressure Regulating Hydrant Valve

Model 420-HY Pressure Regulating Hydrant Valve Model 420-HY Pressure Regulating Hydrant Valve INSTALLATION OPERATION MAINTENANCE 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment is the most important

More information

TABLE OF CONTENTS. 14 Operating Instructions Load vs. Contact

TABLE OF CONTENTS. 14 Operating Instructions Load vs. Contact Page TABLE OF CONTENTS 3 Part Identification 8 Inspection and Assembly 9 Assembly Instructions 10 Rules for Safe Operation 12 Operating Instructions 14 Operating Instructions Load vs. Contact 15 Care &

More information

Owner s Manual Air Bag Lift Tables

Owner s Manual Air Bag Lift Tables Owner s Manual Air Bag Lift Tables SOUTHWORTH PRODUCTS CORP PO Box 1380, Portland, ME 04104-1380 Telephone: 1-800-743-1000 or 207-878-0700 Fax: 207-797-4734 www.southworthproducts.com service@southworthproducts.com

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE OPERATION OF SEATPOST GIANT LIMITED WARRANTY 1 INTRODUCTION Congratulations

More information

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA C - SERIES Height Adjustable Portable Goal Supports C1000 C2000 Installation & Owner s Instructions Made in the USA This manual explains the proper installation, operation, and maintenance of your Schutt

More information

MANUAL. Sesame. Thermoplastic Tank Technologies

MANUAL. Sesame. Thermoplastic Tank Technologies MANUAL Sesame Thermoplastic Tank Technologies INSTALLATION AND USER GUIDE CONTENT 1. GENERAL 3 2. IMPORTANT 3 3. INSTALLATION EXPANSION VESSEL 4 4. USE EXPANSION VESSEL 5 5. AIR CELL REPLACEMENT 5 5.1

More information