1 Catalog No. C09118F Nitrogen Gas Spring Linked System Components Everything You Need to Construct a Linked System

2 Linked Systems Introduction Numerous Piping Options Many customers recognize the benefits of linking nitrogen gas springs; linked systems allow users to easily monitor, control and adjust pressure from outside the die. In this catalog DDCO has brought together all of the components necessary to easily configure a linked system. Choose from the various types of fittings, hose, control panels and specialty components to design a linked system best suited for your application. DDCO also offers ready-to-install complete linked systems built to customer specifications. Complete Linked Systems from DDCO SMS For those instances where a customer prefers to have DDCO provide a finished system, DDCO offers several options. First is the Sectional Mounting System (SMS ) where DDCO will mount cylinders to a SMS plate and link them using hose, fittings and a control panel based on a customer design. For more information on DDCO s SMS request catalog C13106B. Hose Type Gas Spring Model Obstructions Hole Sizes Finished Plate Thickness Burnout Dimensions Control Panel Standard or Custom Riser Block Requirements SMS-i nother option, which is new from DDCO, is the Sectional Mounting System - Internal (SMS-i ). DDCO will mount cylinders to a plate that has been piped internally. DDCO recommends using the SMS-i as an alternative to traditional manifold systems. For more information on DDCO s SMS-i request catalog C13106B. Gas Spring Model SMS-i Connection Finished Plate Thickness 2 Control Panel Burnout Dimensions Hole Sizes DDCO gas springs used in a SMS-i have a bottom port and are attached to the base plate with a sealing washer and standard mounting hardware.

3 Overview Linked Systems DDCO Gas Springs are grouped by two main classifications: Mini Springs with a Port and Large Springs with a G 1/8 Port. DDCO recommends choosing control panels, fittings and hose type based on port style and application requirements. Port Style Mini Port G 1/8 Large Port Control Panels See pages 5-8 Surge Tanks See page 10 Distribution Blocks See page 9 Gas Springs with Port: Micro Series U.0175 U.2600 LJ and L Series SCR Series FCL Series Gas Springs with G 1/8 Port: U.4600 U UH Series UX Series 90.8 Series SC Series Tools See pages Preferred DDCO MINILink (M8 x 1) D-24 Tapered (M12 x 1.5) Compatible Fitting Styles Zip (CNOMO) (S12.65 x 1.5) Preferred O-Ring Face Seal (ORFS) () See page 16 See page 15 See page 17 See pages Hose System (Y-700) Hose (Y-705) Hose Preferred (Y-500) Hose Preferred (Y-400) Hose (Y-250) Hose See page 11 See page 11 See page 11 See page 11 3

4 Linked Systems Linked Operations Converting from Self-Contained to Linked Mode The following basic steps show how to easily convert DDCO gas springs from self-contained to linked mode. For more detailed instructions, refer to the relevant product catalog. (Mini series gas spring with port shown below.) CUTION lways wear safety goggles when performing maintenance on nitrogen gas springs. 1. Remove Protective Screw 2. Safely Exhaust Gas Spring 3. Remove Valve 4. Install Port dapter Recommendations for Linked Systems llow ample space to secure hoses to plate. It is preferred that hoses rest side by side. Torque Specifications rrange gas springs to provide uniformity and balance within the die. Use multiple panels for large systems to allow faster filling and discharging. When linking cylinders allow for ample hose to avoid taut connections. Tighten fittings to the following torque specifications to prevent damage and loosening from vibration during operation. Type Thread lb in lb ft N m Port dapter x MINILink Hose dapter M8 x G 1/8 Port dapter ORFS Hose dapter D-24 Hose dapter M12 x 1.5 Hand-tight then ¼ turn with wrench Zip Hose dapter S12.65 x 1.5 Hand-tight Use two wrenches, one on the port adapter and one on the hose adapter, to avoid over-tightening. The drawings below depict the importance of torque specifications in common port and hose adapter combinations. Mini Port dapter 3 N m MINILink Hose dapter 3 N m Mini Port dapter 3 N m ORFS Hose dapter 23 N m Mini Port dapter + MINILink Hose dapter Mini fittings and hose adapters have low torque values. Refer to the chart above to avoid possible damage from over-tightening. Mini Port dapter + ORFS Hose dapter The torque requirement for the Mini Port dapter is smaller than the ORFS Hose dapter. Refer to the chart above. Do not torque port fitting with larger hose adapter nut. NOTE: It is important to adhere to these guidelines for the following fittings: and

5 Convertible Control Panel Components: Control Panels BV-4G Bleed Valve 4 x G 1/8 Port x M10 SHCS 3/8 SHCS Linked Systems Default Port Mounting Options The DDCO Convertible Control Panel is used to fill, drain and monitor the pressure of linked DDCO nitrogen gas springs from outside the die. The panel consists of four G 1/8 ports, a high pressure 63 mm diameter gauge, a quick disconnect fill valve, a bleed valve and a rupture disk to prevent overpressurization. For maximum versatility, the panel is available with a variety of fitting connections. See below for information on the riser blocks available for use with the control panel RD-400G Rupture Disk (BP = 400 bar / 5800 psi) Filler Valve DPG-3RB PSI/Bar Gauge Ordering Example: Shown with optional bottom guard P 1 N x M8.63 SHCS 5/16 SHCS.1 Convertible Control Panel Gauge Style PSI/Bar Gauge (DPG-3RB) = P Bar/MPa Gauge (DPG-3RM) = When not specified, default is P. Guard Top Guard = 1 Top and Bottom Guards = 2 When not specified, default is 1. NOTE: The P2S is a direct replacement of DDCO s Fitting Connection N = No Fitting Supplied, M = Manifold Seal, S = ORFS Fitting, D = D-24 Fitting, B = Zip Fitting, L = MINILink Fitting When not specified, default is N. Riser Block for Convertible Control Panel DDCO offers the , , and the Riser Blocks for use with the Convertible Control Panel for maximum mounting versatility. It allows for easy mounting of the Control Panel to SMS plates M10 SHCS 3/8 SHCS M10 SHCS 3/8 SHCS M10 SHCS 3/8 SHCS Shown with the riser block or recommended

6 Linked Systems Components: Control Panels Common Control Panel V The DDCO Common Control Panel is used to fill and monitor the pressure of linked DDCO Nitrogen Gas Springs from outside the die. The panel consists of a high pressure gauge (MPa and bar), quick disconnect fill valve, and a rupture disk to prevent overpressurization. This Control Panel conforms to the Toyota standard. Ordering Example: Mini Convertible Control Panel Fitting Location CS RD-400G Rupture Disc (BP = 400 bar) 2x M10 SHCS 3/8 SHCS Common Control Panel Gauge Style Bar/MPa Gauge = PSI/Bar Gauge = P B mm Dia. DPG-3ML Gauge (MPa/bar) Fitting Connection No Fitting = N Zip Fitting = B Guard Options None = N Top Only = 1 Top and Bottom = 2 3 x G 1/8 Port Default G1/8 Port Default Port The DDCO Mini Convertible Control Panel is used to fill, drain and monitor the pressure of linked DDCO nitrogen gas springs from outside the die. The panel is compatible with SMS-i and traditional linked systems and has five ports, a high pressure gauge, a quick disconnect fill valve, a bleed valve and a rupture disk to prevent overpressurization. To allow for maximum versatility when linking, the panel is available with a variety of fitting connections. Port 4 x SHCS 1/4 SHCS RD-400G Rupture Disk (BP=400 bar / 5800 psi) Back View Mounting Options G 1/4 Port Ordering Example: P N Mini Control Panel Gauge Style PSI/Bar Gauge = P Fitting Connection N = No Fitting Supplied, M = Manifold Seal, S = ORFS Fitting, D = D-24 Fitting, B = Zip Fitting, L = MINILink Fitting When not specified, default is N. DPG-3RL Pressure Gauge x Port BV-4G Bleed Valve 2 x G1/8 Port Filler Valve

7 Components: Control Panels Linked Systems Compact Control Panel The smallest of our control panels, the DDCO Compact Control Panel is used to fill, drain and monitor the pressure of linked DDCO nitrogen gas springs from outside the die. The panel consists of two G 1/8 ports, a high pressure gauge, a quick disconnect fill valve, a bleed valve and a rupture disk to prevent overpressurization. To allow for connection to Electronic Pressure Monitors, the panel comes standard with a G 1/4 port. For Electronic Monitor options, see page 20. Bleed Valve Default Port 2 x G 1/8 Port RD-400G Rupture Disk (BP=400 bar / 5800 psi) G 1/4 Port x SHCS 1/4 SHCS DPG-3RL Pressure Gauge Filler Valve Ordering Example: P N. Compact Control Panel Pressure Monitor Sensor Options (optional) EDS = Electronic Pressure Switch, DSK = Piston Pressure Switch, DPS= Dial Pressure Switch, DPT = Electronic Pressure Transmitter Gauge Style PSI/Bar Gauge = P Bar/MPa Gauge = When not specified, default is P. Fitting Connection N = No Fitting Supplied, S = ORFS Fitting, D = D-24 Fitting, B = Zip Fitting, L = MINILink Fitting When not specified, default is N. Mini Control Panel G For Retrofit Only RD-400G Rupture Disk (BP=400 bar / 5800 psi) The DDCO G Mini Control Panel is used to fill, drain and monitor the pressure of linked DDCO nitrogen gas springs from outside the die. The panel consists a high pressure gauge, a quick disconnect fill valve, a bleed valve and a rupture disk to prevent overpressurization. To allow for maximum versatility when linking, the panel also contains eleven different port locations Filler Valve DPG-3RL Pressure Gauge 2 x SHCS 1/4 SHCS BV-4G Bleed Valve Mounting Options x Port 2 x SHCS 1/4 SHCS 7

8 Linked Systems Components: Control Panels Multi Panel The DDCO Multi Panel features modules that may be filled, monitored, adjusted and vented from outside the die, either commonly or individually. No other control panel offers the advantages of the DDCO Multi Panel. For replacement parts refer to bulletin B04105B Rupture Disk BVM-4 (Includes bleed valve, rupture disk and fasteners) 44.5 x (N-1) 1 x (N-1) 1 Open BVM-4 Bleed Valve to bleed 2 N Close valves to isolate modules ORFS Port dapter (N) Places VM-51 Valve ssembly (ssembly includes valve, block and fasteners) Features Each module features a simple two position valve for easy operation. Three port locations on each module give maximum piping flexibility. Each module is supplied with a straight service fitting. (For unused ports, DDCO recommends closing the module off before filling or using tube end caps, , on the unused port.) The panel can be flush mounted on the bottom or back. n optional tilt-guard protects all control valves and gauges during operation. Filler Valve Contact DDCO for pressure monitor options Optional Port dapter Location Standard Port dapter Location Mounting Options x (N-1) 1 x (N-1) 44.5 x (N+1) 1 x (N+1) (N) DPG-3R Gauges 4 x SHCS 1/4 SHCS Mounting Holes Optional Port dapter Location Top Guard Bottom Guard Both Guards Ordering Example: Guard Location: Standard (No Guard) = 401, Top = 402, Bottom = 403, Both = 404 For optional reversed mounting, add R. Number of Modules: 2-6, 8 or 10 8

9 Components: Distribution Blocks Linked Systems DDCO s distribution blocks are used with a control panel to simplify piping to multiple cylinders with a uniform system pressure. and G 1/8 port options are available. Mini Distribution Blocks The Mini Distribution Blocks feature four or eight port locations. Plug unused ports with Port Plug before charging the system Ø x SHCS x Port x Port Compact G 1/8 Distribution Blocks The Compact Distribution Block has 6-12 G 1/8 ports. Plug unused ports with Port Plug before charging the system Top Port 8.31 L/2 L B 30 N 4 x M End Top Side Model (Total 15 Ports Port Ports.59 Ports) N x G 1/ L B Standard G 1/8 Distribution Blocks / / The Standard Distribution Block features 4, 10 or 12 G 1/8 ports. Plug unused ports with Port Plug before charging the system. Refer to bulletin B03142B for more information M10 SHCS Port model also available, refer to bulletin B03142B x G 1/8 Port 2 x M10 SHCS C-Bored Both Sides x M10 SHCS 12 x G 1/8 Port

10 Linked Systems Components: Surge Tanks DDCO surge tanks are used with open-flow systems to increase the volume in the system thereby reducing the pressure rise when cylinders are stroked. The Surge Tank is offered in two Models: F Free Flow Model has multiple open ports supplied as standard for maximum flexibility when piping; M1 SMS-i Model has a bottom port to attach to a base plate. Gauges and shut-off ball valves are available upon request. For assistance in determining appropriate surge tank size for your system, use the DDCO Force Calculator from our website, (Y-400) hose is the preferred hose to use with surge tanks (Y-700)/ (Y-705) hose is not recommended for use with surge tanks due to restricted flow capability. ST B29 4 x G 1/8 Port (Plugged) G 1/8 Port (Plugged) Safety tab for vertical mounting 10 mm Preferred Mounts for Surge Tanks. See the / 90.8 Series Catalog for mount details. B B X+Y X+Y ød 4 x G 1/8 Port (Supplied with plugs) ød G 1/8 Port NOTE: B11 mount available with ST.30-ST models only B H ød K See CYL REF F Free Flow Model M1 SMS-i Model ST D X Y Volume of Tank L (in 3 ) M1 Bottom Port See CYL REF F E G J Surge Tank CYL REF X+Y D E F G H J K x M10 3/ x M / x M / x M / SMS-i Surge Tank Connection DDCO surge tanks ordered with the M1 operating system are used in a SMS-i and have a bottom port. These tanks are attached to the base plate with a sealing washer and standard mounting hardware Ordering Example: Size: 30, 50, 75, 100 Length (Y): 50, 100, 150, 200, 250, 300, 350, 400 ST TO. F Operating System: F = Free Flow Fitting, M1 = SMS-i (Bottom port + sealing component) Mount Option: TO = Basic Model. When not specified, default is TO. Mount ordered with cylinder will be attached at factory. Charging Medium: Nitrogen Gas Charging Pressure Range: bar ( psi) Operating Temperature: 4 C 71 C (40 F 160 F)* *Note: Surge Tank pressure should not exceed 264 bar (28 psi) at maximum temperature.

11 Preferred MINIFLEX (Y-700) Hose + Offers the smallest possible bend radius available for flexible hose + Compatible with Mini, ORFS, D-24 and Zip style fittings Cannot be linked with a surge tank Components: Hose MINIFLEX (Y-705) Hose + Compatible with Mini, ORFS, D-24 and Zip style fittings + High burst pressure Cannot be linked with a surge tank Large bend radius Linked Systems Preferred DDCOFLEX (Y-500) Hose + Higher working pressure than (Y-250) without sacrificing bend radius or flow rate + Compatible with ORFS and D-24 style fittings + Can be linked with a surge tank DDCOFLEX (Y-400) Hose + Can withstand high pressures while maintaining a good flow rate + Can be linked with a surge tank Least flexible bend radius DDCOFLEX (Y-250) Hose + ssemble in field without additional tools using non-crimped adapters 0 bar (2750 psi) is maximum for surging pressure DF Tubing DF. Length (mm) + Extremely durable and compact Dimensions critical, no flexibility NOTE: To order straight lengths of DF Tubing, use the part number above. For curved pieces, it is necessary to provide a drawing. Refer to Bulletin B02118B for more information. Preferred Preferred Part No. OD ID Working Pressure Burst Pressure Bend Radius Crimp Die bar 1890 bar 15 (Y-700) psi psi.59 Mini-Crimp bar 40 bar 20 No Ring Required (Y-705) psi psi bar 10 bar 80C-P03 Gray Die (Y-500) psi psi 82C-R01 Ring bar 10 bar 50 80C-P04 Red Die (Y-400) psi psi C-R01 Ring bar 758 bar 80C-P04J Red Die (Y-250) psi psi 82C-R01 Ring DF Tubing bar 1000 bar 15.9 ssembly at psi psi.625 DDCO DDCO offers hydraulically or pneumatically operated crimping units, turn to page 22 for more information. Hose ssembly DDCO hose assembly consists of a length of hose with a hose adapter on each end. Refer to bulletin 99B105F for more information on ordering a hose assembly. Hose ssembly Ordering Example: S843. S I Hose Type (700, 705, 500, 400 or 250) Hose dapters Sealing Type Example ORFS S943 D-24 D843 Mini L943 Zip B943 Reference appropriate sealing type prefix (S, D, L or B). Hose Straps ø (HS-701) for use with and hose types ø (HS-700) for use with and hose types ø5.2 Orientation Hose adapter orientation: I, C or S Length of Hose ssembly (L) in mm Distance between sealing faces (HS-250) for use with , and hose types ø I C S (HS-500) for use with and hose types Orientation L L L ø (HS-400) for use with , and hose types 11

12 Linked Systems Components: ORFS Hose dapters DDCO was the first gas spring manufacturer to offer O-Ring Face Seals (ORFS). DDCO s ORFS fittings prevent any loss of high pressure nitrogen gas by providing elastomeric seals at every joint. DDCO recommends using DDCO brand hoses featured on page 11 with the adapters shown throughout this catalog. If the length of hose required is less than the H Value, use DF Tubing (page 11) or Solid Hose Fittings (page 13). DDCO also offers a variety of stainless steel fittings to be paired with Y-705 or Y-500 hose for linked operation in extreme condition environments..ss Crimped Hose dapters for or (Y-700 or Y-705) H Value = 75 (2.95) Minimum recommended hose length H = Stainless Steel Option vailable SS (S-943) Straight Swivel Crimped Hose dapters for (Y-500) H Value = 80 (3.15) (S-954) 45 Swivel (S-959) 90 Swivel (S-859) SS (S-843) Compact Swivel Crimped Hose dapters for or (Y-250 or Y-400) H Value = 85 (3.35) (S-743) Compact Swivel (S-851) Retractable Swivel (S-751) Retractable Swivel Non-Crimped Hose dapters for (Y-250) H Value = 85 (3.35) (S-854) 45 Female Face Seal (S-754) 45 Female Face Seal (S-859) Short Neck (S-858) Long Neck (S-759) Short Neck (S-758) Long Neck (S-858) (S-759) (S-758) (S-643) Compact Swivel (S-651) Retractable Swivel (S-654) 45 Female Face Seal (S-659) 90 Female Face Seal

13 Components: ORFS Fittings Linked Systems Solid Hose Fittings Solid hose fittings come in predetermined lengths and are ideal for limited space applications. They can replace traditional hose assemblies, particularly when the length of hose required is shorter than DDCO s recommended minimum hose length (see H Values on page 12). For custom lengths of solid hose, see DF Tubing on page 11. Metric English Port dapters Part No. B xxxx (S-9xxx) mm ORFS ORFS Part No. B xxx (S-8xx) in B DDCO s O-Ring Face Seal (ORFS) Fittings have elastomeric seals at every joint. G 1/ (S-115) Straight.SS Refer to Page 4 Torque Specifications (S-116) (S-117) Extended Straight.SS = Stainless Steel Option vailable ORFS HEX.4.76 ORFS HEX ø (S-121) Swivel Straight G 1/ (S-122) Straight G 1/ (S-123) Swivel Straight (G-109) Flush Plug (S-4) Run Tee Part No. 230.SS (S-330) (S-230) 45 Elbow (S-439) Branch Tee Part No. 439.SS

14 Linked Systems Components: ORFS Fittings Fittings (S-112) Tube End Cap (S-303) Union (S-201) Elbow (S-401) Tee (S-501) Cross Standard Swivel Nut Fittings (S-221) 90 Elbow Port dapter Shown (S-433) Branch Tee (S-432) Run Tee Compact Swivel Nut Fittings (SJ-221) 90 Elbow Port dapter Shown (SJ-433) Branch Tee (SJ-321) 45 Elbow Retrofit Port dapters ORFS ORFS ORFS (S-102) Straight Port dapter 1/4 NPT 1/4 NPT (S-202) 90 Swivel Port dapter 7/16-20 SE-4 O-Ring (S-120) Straight Port dapter (D-104) Flush Plug 7/16-20 SE-4 O-Ring 14

15 Components: D-24 Tapered Fittings D-24 Hose System with or (Y-700 or Y-705) 14 Hex Linked Systems DDCO s D-24 Fittings have a 24 taper and o-ring. M12x1.5 D-24 Hose System with (Y-500) 14 Hex H Minimum recommended hose length (H) = 75 (2.95) (D-943) Compact Hose dapter DIN EN ISO Taper + O-Ring M12x1.5 Fittings G 1/8 M12x (D-115) Straight Port dapter (D-221) 90 Elbow (D-303) Union 22 H Minimum recommended hose length (H) = 80 (3.15) (D-401) Tee (D-432) Run Tee (D-501) Cross (D-843) Compact Hose dapter M12x1.5 M12x1.5 7/16-20 M12x Hex 14 Hex SE-4 5/8 Hex Refer to Page 4 O-Ring Torque Specifications (D-116) Straight Port dapter (D-120) Straight Port dapter (D-433) Branch Tee M8x (D-321) 45 Elbow M12x (D-607) Reducing Union (D-4) Run Tee (D-854) 45 Hose dapter (D-112) Tube End Cap (D-201) Elbow (D-539) Cross Tee (D-858) 90 Hose dapter (D-439) Branch Tee Part No (D-230) 90 Branch Tee Part No Part No Part No

16 Linked Systems Components: MINILink Fittings MINIFLEX Hose System with or (Y-700 or Y-705) 4.9. L 4.9. M8x1.SS = Stainless Steel Option vailable.1 Minimum recommended distance between sealing faces (L) = 75 (2.95) 8.31 MINILink Fittings L943.L943..I L (mm) Hose ssembly SS (L-943) Permanent Hose dapter Micro Series (C.045 C.250) and small Ultra Force Series (U.0175/U.0325) Port dapters M8x1 M8x M8x (L-122) Micro Service Fitting (L-) Micro Port dapter Extension (L-120) Straight Port dapter M8x1.SS SS SS (L-220) 90 Port dapter (L-429) Branch Tee Port dapter (L-428) Run Tee Port dapter M8x /16-20 SE (L-35) Port dapter Extension G 1/ (S-116) Reducer ORFS Refer to Page 4 Torque Specifications M8x (L-201) Elbow G 1/8 Port dapters M8x (L-401) Union Tee G 1/ (L-303) Union (L-115) Reducer G 1/8 M8x1 M8x (L-55) Reducer 7/ (L-110) Port Plug (L-65) Reducer G 1/ (L-109) Fitting Plug M8x Straight Part No G 1/8 G 1/ Branch Tee Part No G 1/

17 Components: Zip (CNOMO) Fittings Linked Systems Zip Hose System with or (Y-700 or Y-705) S12.65x1.5 Buttress THD H Minimum recommended hose length (H) = 75 (2.95) (B-943) Straight Hose dapter (B-954) 45 Hose dapter (B-958) 90 Short Neck Hose dapter (B-959) 90 Long Neck Hose dapter Fittings S12.65x S12.65x S12.65x Internal Check Valve G 1/8 G 1/4 G 1/ (B-115) Straight Port dapter (B-122) Straight Port dapter (B-0) Port dapter with Valve (B-401) Tee Part No Part No (B-501) Cross (B-230) ngle Swivel dapter (B-439) Two-Way Swivel dapter 17

18 Linked Systems Components: Pressure Monitors Pressure Monitors DDCO offers a variety of pressure monitor options to alert press controllers to changes in system pressure. The and models visually alert the user whether the pressure is at good standing or low while the D model is capable of shutting the press down if it drops below the minimum operating pressure. Model No (DPM-1) (DPM-2) D (DPM-2D) Supply Voltage (DPM-1) D (DPM-2D) (DPM-2) Switch Rating Output Electrical Connection 120 VC - Indicator Light 1/2 NPS 24 VDC - Indicator Light 1/2 NPS 24 VDC 0.4 Indicator Light + SPDT 4-Pin Mini-Change Connector Pressure Range bar psi bar psi bar psi Bulletin No. B00136 B01115 B DDCO-US PRESSURE OK PRESSURE LOW DDCO-US PRESSURE OK PRESSURE LOW psi bar SETPOINT DJUST 3000 psi MX 207 bar 1/4 NPT PORT psi bar SETPOINT DJUST 3000 psi MX 207 bar 1/4 NPT PORT M10 SHCS 3/8 SHCS M10 SHCS 3/8 SHCS Neutral (White) DPM-1 Circuit N.C. G 120 VC Hot (Black) COM N.O. Ordering Example: Model Number , or D Connector BH1 Right BH2 Left BH3 Straight Connector (*Connector options are for D Model only.) R : Pressure < Set Point : Pressure > Set Point DPM-2 Circuit (+) R COM 24 VDC The DPM-1 and DPM-2 models both visually inform the press operator of their Nitrogen Gas Spring system s pressure status. See table for supply voltage. G (-) (1) Black D. *BH1. BP. 102 Plug Pin-Out (4) Green (2) White (3) Red -24 VDC +24 VDC R N.C. Fitting Straight Backing Plate (optional) DPM-2D Circuit (2) WHT G N.O. (1) BLK GRN (4) RED (3) COM : Pressure < Set Point : Pressure > Set Point COM The DPM-2D model visually informs the press operator of the system status, and can be wired into the press controller to automatically shut down or alert the operator when pressure drops below a set point. 18

19 Components: Pressure Monitors Linked Systems Electronic Pressure Monitors DDCO offers two types of Electronic Pressure Monitors to monitor nitrogen gas pressure during operation: n Electronic Pressure Monitor Sensor or a Control Panel with Pressure Monitor. For maximum versatility both types have multiple configurations to best suit your application. Pressure Monitor sensor options are detailed on page 20. Electronic Pressure Monitor Configuration To customize your Electronic Pressure Monitor, select the base, sensor and cable accessory that best suits your application. Cable ccessory M12.S M12.L. ttachment Orientation: S = Straight ttachment Orientation: L = Elbow Cable Length: 02 = 2 m, 05 = 5 m, 10 = 10 m pplicable for EDS, DPS & DPT sensor options x SHCS Guard Option G Pressure Monitor Sensor Options EDS DSK DPS DPT See page 20 for details. Base Options Example shown: CP.S.EDS.G With M12.S Cable JB CP GM specific option available, reference bulletin B Ordering Example: Model Number Base Option CP = Block with Bleed Valve, Filler Valve and Rupture Disk JB = Block only (Bleed Valve, Filler Valve and Rupture Disk not included), CP. S. EDS. G Guard Option Pressure Monitor Sensor Options EDS = Electronic Pressure Switch, DSK = Piston Pressure Switch, DPS= Dial Pressure Switch, DPT = Electronic Pressure Transmitter Fitting Connection N = No Fitting Supplied, S = (ORFS), D = (D-24), B = (Zip), L = MINILink Fitting. Default is N.

20 Linked Systems Components: Pressure Monitors Electronic Pressure Monitor Sensors The Electric Pressure Monitor has four sensor options available: EDS, DSK, DPS and DPT. Review the details provided below to select the correct option for your application. EDS Electronic Pressure Switch The EDS switch features an LED digital display that reads pressure value in bar, psi or MPa. The EDS models display face rotates 270 while the body rotates 340 for added versatility, the sensor also features two switching outputs that can be easily set with face mounted push buttons. Note: EDS uses M12 style cable accessory. Features: Measuring Range: bar ( psi) Output: (2) PNP Pin 2, 4 Supply Voltage: 9 35 VDC Electrical Connection: 4 pole M12 x 1 Switch Rating: 1.2 max Current Consumption: 35 m max DSK Piston Pressure Switch The DSK switch uses a pressure input to operate a SPDT switch as the pressure rises or falls across a set value. The manually adjusted switch monitors a preset pressure. This switch can be set at the factory and wired to shut down a press operation or activate an alarm once pressure is above or below the set-point. Note: DSK includes a DIN cable adapter ø G 1/4 4-Pin M12 x 1 25 HEX 1.00 DIN Cable dapter (2) White (1) Brown (3) Blue + 9 to 35 VDC (4) Black Circuit Diagram Sensor View lmax = SP 1 lmax = SP 2 Circuit Diagram Pin Color 1 Brown 2 White 3 Blue 4 Black Pressure < SP1 Pressure > SP1 Sensor View 2 NC 1 COM 4 NO SP1 20 Features: G 1/4 27 HEX 1.06 Max Pressure Rating: 600 bar (8700 psi) Range Tolerance: ± 5 bar (± 72.5 psi) Output: SPDT Switch Switch djustment Range: bar ( psi) Electrical Connection: DIN Switch Rating: 1 MP at 250 VC, 4 MP at 24 VDC DPS Dial Pressure Switch The DPS switch features two manually adjustable dials. The upper dial is the set pressure and the lower dial is the reset pressure. When the system pressure increases to the set value, Output 1 (pin 4) turns on, and Output 2 (pin 2) turns off. When the system pressure decreases to the Reset Pressure, Output 1 turns off and Output 2 turns on. Note: DPS uses M12 style cable accessory PIN M12 X1 G 1/ HEX Locking Knob Set Point djustment Reset Point djustment (2) White (1) Brown 3 GND Circuit Diagram 4: N.O. 2: N.C. Sensor View Pin Color 1 Brown 2 White 3 Blue 4 Black Features: Measuring Range: bar ( psi) Electrical Connection: 4 - Pole M12 x 1 Operating Voltage: VDC Current Consumption: <25 m Setting Point Range: bar ( psi) Switch Output: PnP (1 N.O. & 1 N.C. Complementary) Reset Point Range: bar ( psi) Switch Point ccuracy: < ± 2.5% Switch Rating: 500 m (3) Blue (4) Black to 32 VDC -

21 Components: Pressure Monitors Linked Systems DPT Electronic Pressure Transducer DDCO s DPT unit is a pressure transducer, emitting an analogue signal that provides a range of voltage. The DPT converts pressure input to a 0 10 V output, the voltage output can then be scaled by a press controller to read the pressure value. Note: DPT uses M12B style cable accessory. Features: ø22.86 G 1/ Pin M12 x HEX (2) White (1) Brown (3) Blue 12 to 32 VDC Circuit Diagram Pin Color 1 Brown 2 White Sensor View V (0 600 bar) ( psi) 3 Blue 4 Black Supply Voltage: VDC Max Pressure Rating: 600 bar (8700 psi) ccuracy: 0.5% Full Scale Electrical Connection: 4 Pin M12 x 1 Output Signal: nalog (0-10 Volts) Current Consumption: <15 m (4) Black nalog Control Panel with Pressure Monitor M12 5P Input/Output ø11 Thru The Control Panel with Pressure Monitor is used to fill and monitor the pressure of linked nitrogen gas springs from outside the die. The panel is adjustable to read pressure in bar, psi or MPa and includes a digital pressure sensor with programmable output to signal if pressure drops below a preset level. This panel conforms to Toyota standard number D-PCPS-B mm Dia. DPG-3ML Gauge B C D CS Filler Valve Digital Pressure Display RD-400G Rupture Disc (BP = 400 bar) This product is Listed to applicable UL Standards and requirements by UL Reference B10143 for additional information Cable ccessory M12B.S M12B.L. ttachment Orientation: ttachment Orientation: S = Straight L = Elbow Cable Length: 02 = 2 m, 05 = 5 m, 10 = 10 m Ordering Example: Plate Style B= English plate style *For Japanese plate order B. Fitting Location B, C, D, BD Output: SPST N.O. (Normally Open) Max Pressure Rating: 350 bar (5076 psi) Supply Voltage: VDC, Electrical Connection: M12 (B Code), 5 Wire, VC (50 60 Hz) Reverse Key 21

22 Linked Systems Tools Tools for Hose ssembly Construction DDCO carries a variety of tools for Hose ssembly Construction, please refer to bulletin B11110B for more information on the selection shown below. Mini Hose Cutter Used to cut hose to appropriate length. The works with all hose sizes. Hose ssembly Clamp Used to secure hose while installing hose adapters. The is for use with the / (Y-700 / Y-705) hoses, and the is compatible with all hose sizes. Mini Hose Cutter Mini Hose ssembly Clamp Hose ssembly Clamp (HC) Portable Crimping Unit Used with appropriate die ring to create permanent hose assemblies. For more information, request bulletin B04112B. Mini-Crimp Used in a crimping machine to construct hose assemblies using / (Y-700 / Y-705) hose. Crimp Dies Used in Portable Crimping Unit to construct hose assemblies. For information on constructing hose assemblies, refer to bulletin B00120D. Die Ring Crimp Die Part No / (Y-700 / Y-705) (Y-500) (Y-400) (Y-250) Crimp Die Mini-Crimp No Ring Required 80C-P03 Gray Die 82C-R01 Ring 80C-P04 Red Die 82C-R01 Ring 80C-P04J Red Die 82C-R01 Ring Crimp Diameter mm / inch Using DDCO s Mini-Crimp 1. Place the Mini-Crimp into the crimping machine. No die ring is required. 2. Insert the hose assembly from below through the center of the Mini-Crimp (F.1). For instructions on constructing a Mini Hose ssembly request bulletin B11110B. 3. ctivate the hydraulic or pneumatic crimping machine to permanently crimp fitting to the hose (F.1). Crimp entire length of ferrule 4. s the DDCO Mini-Crimp begins to close, position the fitting to ensure the entire length of the ferrule is crimped (F.2). 5. Remove completed hose assembly from the Mini-Crimp. 6. Measure the crimped ferrule diameter across the flats to verify it is within the crimp dimension range (F.3). Ferrule F.1 F.2 F.3 22

23 Tools Linked Systems Charging ccessories Quick Disconnect Charging Hardware Use the DDCO Quick Disconnect Charging ssembly, , with the or Charging Nipple or the Pressure nalyzer to charge selfcontained gas springs. The can also be used with a DDCO control panel to charge linked systems. The Quick Disconnect Filling ssembly with self-venting capabilities releases residual pressure after charging self-contained or linked nitrogen gas spring systems for easy decoupling between the filling assembly and charging nipple or filler valve. DDCO also offers the High Pressure Charging ssembly to charge Micro Series, SCR Series and U.0175 U.0400 nitrogen gas springs to maximum pressure. Quick Disconnect Filling ssembly with Gauge, , is also available Hose ssembly m / 10 ft Standard Pressure Regulator Quick Disconnect Filling ssembly (Self-Venting) Standard Pressure Regulator Hose ssembly m / 10 ft Quick Disconnect Filling ssembly * *Not recommended with B or Quick Disconnect Charging Nipple ( Port) (G 1/8 Port) Use the appropriate Quick Disconnect Charging Nipple to charge DDCO Nitrogen Gas Springs. For additional information request bulletin B Safety Plates DDCO recommends customers identify tools containing high pressure nitrogen gas springs to ensure proper handling of the cylinders. DDCO offers several caution tags to meet specific application needs. For more information request bulletin B01130B. Compact Nitrogen Gas Booster DGB.100 DDCO s Compact Nitrogen Gas Booster System, DGB.100, is a lightweight, cost-effective way to extend the life of your nitrogen supply tanks. Using the DGB.100, tanks with low pressure can be boosted to a higher pressure that is suitable for charging the gas spring. For more information refer to bulletin B Nitrogen Gas Booster System DGB.150 DDCO s Nitrogen Gas Booster System, DGB-150, is an all-in-one solution to the problems of low pressure supply tanks and lost nitrogen gas during discharge. For more information on the booster, refer to bulletin B

24 Complete Linked System Solutions The global leader in nitrogen gas spring technology 450 Plymouth Oaks Blvd. Plymouth, Michigan US DDCO.US fax Printed in US DDCO, Inc ll Rights Reserved Product changes may occur during the life of this catalog without prior notice, but products supplied will remain functionally interchangeable.

Catalog No. C09118A. Nitrogen Gas Spring Linked System Components

Catalog No. C09118A. Nitrogen Gas Spring Linked System Components Catalog No. C09118A Nitrogen Gas Spring Linked System Components Everything You Need to Construct a Linked System Linked Systems Introduction Numerous Piping Options Many customers recognize the benefits

More information

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal Hose TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal METAL FORMING SOLUTIONS THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS Table of

More information

Nitrogen Gas Spring Hose System Components

Nitrogen Gas Spring Hose System Components Nitrogen Gas Spring Hose System Components Control Panels TNKMAN Distribution Blocks Compression Tanks Hose Systems with Hoses, Fittings and Adapters Micro EO24 Hose and Tube System EZ-Hose System EO24-Hose

More information

Up to 95 kn of force on contact UltraPak cartridge for long life Operates self-contained or linked

Up to 95 kn of force on contact UltraPak cartridge for long life Operates self-contained or linked atalog No. 010102 Nitrogen Gas prings UT eries Up to 95 of force on contact UltraPak cartridge for long life Operates self-contained or linked UT eries Nitrogen Gas prings Introduction The global leader

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard

More information

New Models! UX.1600 UX.20000

New Models! UX.1600 UX.20000 atalog No. 07105 Ultra Force Extended UX eries New Models! UX.1600 UX.000 Patent pending Reduce die construction costs ong stroke lengths Directly upgrade IO 750-10000 models Variety of attachable and

More information

Torque Specifications

Torque Specifications SENR3130-10 Torque Specifications All Caterpillar Products S/N From the library of Barrington Diesel Club CONTENT General Information 01/07/2005 Introduction to Torque 01/07/2005 Torque-Turn 01/07/2005

More information

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A] RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.

More information

DI-DRO ADVANCED FORMING SYSTEMS

DI-DRO ADVANCED FORMING SYSTEMS DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

// ADapters GUIDelines

// ADapters GUIDelines // ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked

Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked atalog No. 10111 High Force Nitrogen Gas prings UH eries Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked UH eries Nitrogen Gas prings Introduction

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

Worldwide Contacts. General Description

Worldwide Contacts.  General Description Worldwide Contacts www.tyco-fire.com AQUAMIST Red-E Mist Supply Skid Table of Contents Sections General Description....1 Training...3 Technical Data...3 Skid Operation...3 System Components...6 Planning...6

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

Cryogenic Liquid Ultimate Liquid Cylinder Hose

Cryogenic Liquid Ultimate Liquid Cylinder Hose Cryogenic Liquid Ultimate Liquid Cylinder Hose Flexible Components brand liquid cylinder hose is considered the highest quality liquid cylinder hose on the market. It effectively transfers cryogenic liquids

More information

PED 97/23/EC COMPLIANT. Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked

PED 97/23/EC COMPLIANT. Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked atalog No. 10111A High Force Nitrogen Gas prings UH eries Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked PED 97/23/E OMPIANT UH eries Nitrogen Gas

More information

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel)

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel) // FITTINGS GUIDelines FITTING IDENTIFICATION numers Most fluid piping system sizes are measured by dash numbers. These are universally used abbreviations for the size of component expressed as the numerator

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

AT SERIES. Dart Valve Actuator. Thrusts up to 55,000 lbs SIL-3 Capable GT3 Triple Seal Gland for Severe Service Applications

AT SERIES. Dart Valve Actuator. Thrusts up to 55,000 lbs SIL-3 Capable GT3 Triple Seal Gland for Severe Service Applications Actuation Solutions and Systems for the World s Most Challenging Environments AT SERIES Dart Valve Actuator Durable, Accurate, Compact, Modular Thrusts up to 55,000 lbs SIL-3 Capable GT3 Triple Seal Gland

More information

Coiling Tube with Twist-Proof Fitting

Coiling Tube with Twist-Proof Fitting http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

VR46.5V(A)/VR86.5V(A) SERIES

VR46.5V(A)/VR86.5V(A) SERIES VR46.5V(A)/VR86.5V(A) SERIES COMACT COMBINATION GAS CONTROS WITH INTEGRATED 1:1 GAS/AIR REGUATOR FOR AUTOMATIC IGNITION SYSTEMS SECIFICATIONS INSTRUCTION SHEET Subject to change without notice. rinted

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Fittings, Materials and Tubing Guide. Instrumentation Products

Fittings, Materials and Tubing Guide. Instrumentation Products Fittings, Materials and Tubing Guide Fittings, Materials and Tubing Guide Instrumentation Products MPI Medium Fittings Introduction Hannifin Fittings are engineered and manufactured to provide secure,

More information

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K

More information

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Hand Valve Series 556 Control Open/Close for Air Supply. Release Residual

More information

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12 PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN

More information

Oxidation Stability of Gasoline and Aviation Fuels

Oxidation Stability of Gasoline and Aviation Fuels Oxidation Stability of Gasoline (Induction Period Method) Oxidation Stability of Aviation Fuels (Potential Residue Method) Test Method Provides an indication of the tendency of gasoline and aviation fuels

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

www.ricelake.com/condec 888-295-8475 UPC5000 PRESSURE CALIBRATION STANDARD Designed for calibrating transmitters, transducers, gauges and other pressure sensitive devices onsite, the portable UPC5000 is

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK

More information

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS 262-2040 Hot Tapping Machine For performing 1/4 6 Hot taps 285 psi or less. Municipal Water, Sewage, & Building Services Use OPERATIONS MANUAL and OPERATING INSTRUCTIONS WARNING: These instructions are

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Sample C ylinde rs, Acce ssorie s, and O utage Tube s www.swagelok.com Sample C ylinde rs, cce ssorie s, and O utage s Features Sizes from 10 to 3785 cm 3 (1 gal) Working pressures up to 5000 psig (344 bar) 304L and 316L stainless steel and alloy 400 2 Sample

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier Tentec Page 1 w w w. t e n t e c. n e t Instruction Document Mini Air Driven Pump Unit Model: HTT.627X Series HTT.6271 Maximum Working Pressure = 1500bar (21750 psi) HTT.6272 Maximum Working Pressure =

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using The compact-size pressure gauge can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Fluid medium Indicated pressure

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Three-way Changeover Valve Change Valve Changeover Air Direction by 90 Lightweight and Compact Design. Fine Operability and

More information

Push-In Fitting Type with Stop Valve

Push-In Fitting Type with Stop Valve http://www.pisco.co.jp Push-In Fitting Type with Stop Valve 278 Push-In Fitting Type with Stop Valve for General Pneumatic Piping. Air Stop by Tube Disconnection. Easy Insertion and Disconnection by Double-passage

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

Installing a Probe. Typical Installation

Installing a Probe. Typical Installation for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assemblies

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

SERVICE MANUAL No. I-0043

SERVICE MANUAL No. I-0043 Bettis Canada Ltd. 4112 91A Street Edmonton, Alberta, Canada T6E 5V2 Tel: (403) 450-3600 Fax: (403) 450-1400 SERVICE MANUAL No. I-0043 Edmonton GAS/HYDRAULIC ADDITIONAL COMPONENTS CUSTOMER: P.O.#: W.O.#:

More information

IFP C175-* REMOTE CONTROL RELIEF VALVE

IFP C175-* REMOTE CONTROL RELIEF VALVE IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM)

More information

3.0 Pressure Transmitter Selection

3.0 Pressure Transmitter Selection 3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure The flow-shut mechanism will operate to stop the air flow when the tube is disconnected and will allow air flow when the tube is connected. The double-passage structure facilitates easy connection and

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122 Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters low cost differential pressure gauge for use in measuring the pressure drop across filters, strainers, separators, valves,

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting. http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Protection Ring from Deformation Insert Ring 668 Protect tubes from deformation. Ultra soft tube is connectable to Fitting. Necessary for the connection

More information