AIR COMPRESSOR INSTRUCTION MANUAL. model no
|
|
- Monica Jefferson
- 1 years ago
- Views:
Transcription
1 model no AIR COMPRESSOR IMPORTANT: Read and understand this instruction manual thoroughly before using the product. It contains important information for your safety as well as operating and maintenance advice. INSTRUCTION MANUAL
2 3 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS 4 SAFETY GUIDELINES 5 KEY PARTS DIAGRAM 8 KEY PARTS LIST 9 INTENDED USE 0 ASSEMBLY 2 OPERATING INSTRUCTIONS 4 MAINTENANCE 8 TROUBLESHOOTING 20 EXPLODED VIEW 22 PARTS LIST 23 WARRANTY 24 TABLE OF CONTENTS NOTE: If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at SAVE THESE INSTRUCTIONS Keep this instruction manual for future use. Should this product be passed on to a third party, then this instruction manual must be included.
3 4 5 model no contact us TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS RUNNING HP TANK SIZE AIR DELIVERY 40 PSI AIR DELIVERY 90 PSI MAXIMUM PRESSURE (PSI) PUMP DESIGN MOTOR POWER WEIGHT POWER CORD EXTENSION CORD *CFM: Cubic feet per minute..5 5 U.S. GALLONS (8.9 L) Oil-less Induction 20 V, 60 Hz, 2 A 58 lb 8 oz (26.5 kg) SJT 6 AWG / 72" (.83 m) SJT 2 AWG / Maximum 30 (9. m) This manual contains information that relates to PROTECTING PERSONAL SAFETY and PREVENTING EQUIPMENT PROBLEMS. It is very important to read this manual carefully and understand it thoroughly before using the product. The symbols listed below are used to indicate this information. Safety Advice. RISK OF FIRE OR EXPLOSION. Do not spray a flammable or combustible liquid or paint near sparks, flames, pilot lights or in a confined area. The spray area must be well-ventilated. Keep compressor at least 20' (6 m) away from spray area. Do not carry and operate the compressor or any other electrical device near the spray area. Never smoke when spraying. Use a minimum of 25' (7.6 m) of hose to connect a spray gun to the compressor. 2. RISK OF ELECTRIC SHOCK. Do not expose to rain. Store the compressor indoors. Hazardous voltage. Disconnect from power source before servicing. Compressor must be grounded. Do not use grounding adaptors. 3. RISK OF BURSTING. Make sure the regulator is adjusted so that the compressor outlet pressure is set lower than the maximum operating pressure of the spray gun or tool. Before starting the compressor, pull the ring on the safety valve to make sure the valve moves freely (see diagram on page 7). Drain water from tank after each use. Do not weld or repair tank. 4. RISK OF PERSONAL INJURY.. Never spray the compressed air or material at self or others. 5. RISK OF BURSTING. Check the maximum pressure rating in the manual or identification label. The compressor outlet pressure must be regulated so that it does not exceed the maximum pressure rating. Relieve all pressure in the hose before removing or attaching accessories. 6. RISK OF BURSTING. Do not adjust the pressure switch or safety valve for any reason. They have been preset at the factory for this compressor s maximum pressure. Tampering with the pressure switch or the safety valve may cause personal injury or property damage. SAFETY GUIDELINES IMPORTANT! Installation, operation or maintenance information that is important but not hazard related. DANGER! Potential hazard that will result in serious injury or loss of life. Potential hazard that could result in serious injury or loss of life. CAUTION! Potential hazard that may result in moderate injury or damage to equipment.
4 6 7 model no contact us SAFETY GUIDELINES 7. RISK OF BURNS. The pump and the manifold generate high temperatures. In order to avoid burns or other injuries, do not touch the pump, the manifold or the transfer tube while the compressor is running. Allow the parts to cool down before handling or servicing. Keep children away from the compressor at all the times. 8. RISK OF BREATHING. Be certain to read all labels when you are spraying paints or toxic materials, and follow all safety instructions. Use a respirator mask if there is a chance of inhaling anything you are spraying. Also, NEVER directly inhale the air produced by a compressor. 9. RISK OF EYE INJURY. Wear ANSI Z87. approved safety goggles when using an air compressor. Do not point any nozzle or sprayer toward a person or any part of the body. Serious injury may occur if the spray penetrates the skin. Extension cords As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequa tely sized wire causes a serious drop in voltage, resulting in loss of power and possible product damage. Refer to the table here to determine the required minimum wire size. Recommended Minimum Wire Gauge for Extension Cords* (20 V) AMPERE RATING CORD SIZE IN AWG (AMERICAN WIRE GAUGE) Extension cord length in feet * Based on limiting the line voltage drop to 5V at 50% of the rated amperes. The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 4 gauge cord can carry a higher current than a 6 gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required. Guidelines for using extension cords Ensure your extension cord is properly wired and in good electrical condition. Alway replace a damaged extension cord or have it repaired by a qualified technician before using it. SPECIFIC SAFETY SAFETY GUIDELINES FOR THE SLIDING WET TILE SAW Protect your extension cords from sharp objects, excess heat, and damp or wet areas. Pull the pressure safety valve ring every day in order to ensure that the valve is functioning properly. The compressor must be located in a well-ventilated area for cooling, and must be a minimum of 2" (3 cm) away from the nearest wall. Protect the air hose and the power cord from damage and puncture. Inspect them for weak or worn spots every week, and replace them if necessary. Always wear hearing protection when using an air compressor. Failure to do so may result in hearing loss. Do not carry the compressor while it is running. Do not operate the compressor if it is not in a stable position. Do not operate the compressor on a rooftop or an elevated position that could allow the unit to fall or be tipped over. Always replace a damaged gauge before operating the unit again.
5 8 9 model no contact us KEY PARTS DIAGRAM H F J E G C D A B A. ELECTRIC MOTOR: The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent the motor from being damaged. B. AIR COMPRESSOR PUMP: The pump compresses the air and discharges it into the tank via the piston that moves up and down in the cylinder. C. ON/OFF SWITCH: This switch turns the compressor on and off. It is operated manually, and when it is in the ON position, it allows the motor to start if the pressure in the air tank is below the factory set cut-in pressure, and allows the motor to stop if the pressure in the air tank reaches the factory set cut-out pressure. Be sure to set this switch to the OFF position when the compressor is not being used and before unplugging the compressor. D. SAFETY VALVE: This valve is used to prevent system failure by draining pressure from the system when it reaches a preset level if the pressure switch has not shut down the motor. It will pop open automatically, or it can be activated manually by pulling the ring on the valve. E. AIR PRESSURE REGULATOR: The regulator is used to adjust the pressure inside the line to the tool that is being used. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease the pressure. F. TANK PRESSURE GAUGE: The gauge measures the pressure level of the air that is stored in the tank. It cannot be adjusted by the operator and it does not indicate the pressure inside the line. G. OUTLET PRESSURE GAUGE: The gauge measures the regulated outlet pressure. H. AIR OUTLET: The outlet is connected to the /4 (6.4 mm) NPT air hose. I. AIR TANK DRAIN VALVE: The drain valve is used to remove moisture from the air tank after the compressor is shut off. J. AIR TANK: The tank is where the compressed air is stored. K. POWER CORD: This compressor should be used on a nominal 20 V grounded circuit. Use a power cord that is equipped with a grounding plug. Verify that the compressor is plugged into an outlet that has the same configuration as the plug. Do not use an adaptor with this compressor. KEY PARTS LIST I K Plug Grounded outlets Grounding pin Do not exceed the tool s maximum working pressure. Do not attempt to open the drain valve when there is more than 0 PSI of air pressure in the tank.
6 0 model no contact us Before you start This Mastercraft Air Compressor is ideal for a wide range of applications, from fastening to greasing and engine cleaning. The 5-gallon (8.9 L) design provides optimum pressure. It features a.5 HP induction motor for quiet operation and a cast-iron, oil-free pump for long-lasting, reliable performance. Tool Compatibility Chart Air Tool Inflation/Recreation Operates Tool Continously Operates Tool Intermittently Not Recommended The procedures described in this manual are solely for this 5-gallon (8.9 L) air compressor at a maximum of P=35 PSI. The device has been designed / constructed for household use only. Brad Nailer (8 gauge) Compatible compressor and air tool: proper usage and operation Finishing Nailer (6 gauge) Always ensure the use of appropriately matched air tools with your Mastercraft Air Compressor. Be sure that the air compressor being used can supply the appropriate volume, pressure and delivery rate of air to the tool(s) without running continuously. Using tools or combinations of tools that, together or separately, require more than the air compressor can deliver will void the air compressor guarantee/warranty. 3-in- Brad/Finishing/Stapler Framing Nailer INTENDED USE Roofing Nailer Flooring Nailer Impact Wrench Die Grinder/Angle Grinder/Air Ratchet INTENDED USE Cut-Off Tools Drill, Hammer/Chisel Shears Sander & Polisher DIY Paint Sprayers Grease/Caulking Gun This air compressor is not designed for continuous operation or unlimited commercial operations and may be used in dry area only. This air compressor is intended to be used in maximum 30-minute intervals and should rest for 30 minutes before used again. Do not exceed the maximum working time.
7 2 3 model no contact us Assembly. Unpack the air compressor unit. Inspect the unit for damage. If the unit has been damaged, contact the retailer immediately. THE CARTON SHOULD CONTAIN: Air compressor Owner s manual Air filter 4. Air filter assembly Screw the air filter () onto the pump. 2. Check the air compressor s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its intended use. 3. Positioning of the air compressor: Position the air compressor () near an electrical outlet (2). The compressor must be at least 2" (3 cm) from any wall (3) or obstruction, in a clean, well-ventilated area to ensure sufficient air flow and cooling. Place the air compressor on the floor or a hard, level surface. The air compressor must be level to ensure proper drainage of the moisture in the tank. ASSEMBLY 5. Connect air hose to compressor Connect the air hose () to the compressor s air outlet (2) with the quick connector (3). ASSEMBLY Wall NOTE: ¼" (6.4 mm) NPT air hose is required for connecting to the air compressor.
8 4 5 model no contact us Break-in procedure 5. Set the ON/OFF switch () to the ON (I) position. The compressor will start. Run the compressor for 30 minutes. If it fails, turn it off immediately and call the toll-free helpline at: Please note that breaking-in the unit is only required prior to first use. 2. Open the tank drain valve () by turning it counter-clockwise to permit the air to escape and prevent air pressure build-up in the air tank during the break-in period. 6. After 30 minutes, turn off the switch. 7. Close the tank drain valve (I) by turning it clockwise. 3. Turn the air pressure regulator knob () counter-clockwise until it stops. 8. Set the ON/OFF switch to the ON (I) position. The air receiver will fill to cut-out pressure and then the compressor s motor will stop. The compressor is now ready for use. 4. Plug in the power cord (). NOTE: A circuit breaker is recommended. If the air compressor is connected to a circuit protected by a fuse, use dual element time delay fuses (type T only). CAUTION! Use a dedicated circuit. For best performance and reliable starting, the air compressor should be plugged into a dedicated circuit, as close as possible to the fuse box or circuit breaker. The compressor will use the full capacity of a typical 5 A household circuit. If any other electrical devices are drawing from the compressor s circuit, the air compressor may fail to start. Low voltage or an overloaded circuit can result in sluggish starting that causes the motor thermal overload protector or circuit breaker to trip, especially in cold conditions. OPERATING INSTRUCTIONS OPERA OPERATING INSTRUCTIONS. Set the ON/OFF switch () to the OFF (O) position.
9 7 model no contact us Before each start-up How to start. Set the ON/OFF switch () to the OFF (O) position.. Close the tank drain valve (). Plug in the power cord (2). 2. Turn the air pressure regualtor knob counter-clockwise until it stops. 2. Set the ON/OFF switch to the ON (I) position and allow the tank pressure to build. Motor will stop when tank pressure reaches cut-out pressure. 3. Turn the air pressure regulator knob clockwise until desired pressure is reached. Shut down procedure. Set the ON/OFF switch () to the OFF (O) position. 2. Unplug the power cord (2). 3. Reduce the pressure in the tank through the outlet hose. Pulling the safety valve ring (3) and keeping it open will also reduce the pressure in the tank. 3. Attach hose () and accessories. Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. If the pump has been transported or turned upside down (even partially), allow the pump to sit in a normal, upright position for approximately 0 minutes before starting. High temperatures are generated by the electric motor and the pump. To prevent burns or other injuries, DO NOT touch the air compressor while it is running. Allow it to cool before handling or servicing. Keep children away from the air compressor at all times. CAUTION! Escaping air and moisture can propel debris that may cause eye injury. Wear safety goggles when opening the drain valve. To avoid personal injury, always shut off and unplug the unit, and relieve all air pressure from the system before performing any service on the air compressor. Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure. OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 6
10 8 9 model no contact us MAINTENANCE ITEM Drain the tank Check the valve Clean the air filter Test for leaks Storage DESCRIPTION/REASON Through normal operation of your air compressor, condensation water will accumulate in the tank. To prevent corrosion of the tank from the inside, condensation must be drained at the end of every workday. Note: Allow unit to cool before draining tank. Drain valve becomes hot during operation. Set the ON/OFF switch to the OFF position. Unplug the power cord. Turn air pressure regulator knob counter-clockwise to set the outlet pressure to zero. Pull and hold ring on safety valve, allowing air to bleed from the tank until air pressure is minimized. Place suitable container under unit to catch water. Slightly tilt unit and turn drain valve counter-clockwise to open. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. Pull/activate the safety valve daily to ensure that it is operating properly and to clear the valve of any possible obstructions. A dirty air filter will reduce air compressor s performance and life.to avoid contaminating the pump, the filter should be cleaned frequently and replaced on a regular basis. Clean the foam filter by immersing it in warm, soapy water. Allow to dry thoroughly. Check that all connections are tight. Small leaks in the tank, hoses, connections or transfer tubes will substantially reduce the air compressor and tool performance. Spray a small amount of soapy water around the area of suspected leaks with a spray bottle. If bubbles appear, repair, replace or re-seal the faulty component. Do not over tighten any connections. Before storing the air compressor, do the following: Drain all moisture from the tank (see Operating Instructions paragraph in the Maintenance section of this manual for the correct procedure). Use an air blow gun to clean all dust and debris from the compressor. Disconnect and wind up the power cord. Drain all moisture from the tank. Pull the pressure safety valve to release all pressure from the tank. Cover the entire unit to protect it from moisture and dust. Store the air compressor in a clean and dry location. In cold weather, store the compressor in a warm building when it is not in use. This will reduce problems related to starting the motor and the freezing of water condensation. SERVICE INTERVAL Daily Daily Weekly Monthly Prior to storing To check safety valve Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, contact a trained service technician. To drain tank. Set the ON/OFF switch (C) to the OFF (O) position. 2. Unplug the power cord (K). 3. Turn air pressure regulator knob (E) counter-clockwise to set the outlet pressure to zero. 4. Pull and hold ring on safety valve (D), allowing air to bleed from the tank until air pressure is minimized. 5. Place suitable container under unit to catch water. 6. Slightly tilt unit and turn drain valve (I) counter-clockwise to open. 7. After the water has been drained, close the drain valve (I) (clockwise). The air compressor can now be stored. NOTE: Allow unit to cool before draining tank. Drain valve (I) becomes hot during operation. NOTE: NOTE: Troubleshooting problems may have similar causes and solutions. Disconnect the electrical plug and disconnect any tools from air supply before attempting any adjustment. If any of the following symptoms appears while operating the product, stop using the product immediately, or serious personal injury could result. Only an authorized service centre should perform repairs on this product. Disconnect the electrical plug and disconnect any tools from air supply before attempting any adjustment. MAINTENANCE
11 20 2 model no contact us TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The power cord is not plugged in. Plug the power cord into a grounded outlet. The ON/OFF switch is in the Set the ON/OFF switch to the ON (I) position. OFF (O) position. The extension cord is the wrong Check the technical specifications page wire gauge or is too long. 7 for the proper wire gauge and cord length. The motor will not run or start. The motor runs continuously when the pressure switch is in the ON position. The motor s thermal overload protection has tripped. A fuse has blown or a circuit breaker has been tripped. The air tank pressure exceeds the preset pressure switch limit. The safety valve is stuck open. Electrical connections are loose. The motor, capacitor or safety valve is defective. The pressure switch does not shut off the motor when the air compressor reaches the cut-out pressure and the safety valve activates. The compressor s capacity is not enough. Turn the air compressor off, unplug the power cord and wait until the motor has cooled down. Plug in the power cord only after the motor has cooled down, however wait at least 5 minutes to make sure the thermal overload protector has recovered. Replace the fuse or reset the circuit breaker. Verify that the fuse has the proper amperage. Check for low voltage conditions. Disconnect any other electrical appliances from the circuit or operate the compressor on a dedicated circuit. The motor will start automatically when the tank pressure drops below the cut-in pressure. Clean or replace the safety valve. Have the compressor serviced by a qualified technician. Have the compressor serviced by a qualified technician. Set the ON/OFF switch to the OFF position. If the motor does not shut off, unplug the air compressor. If the pressure switch is defective, replace it. Check air requirements of the accessory that is being used. If it is higher than the CFM (Cubic Feet per Minute, (page 4) and pressure supplied by the compressor, a larger capacity air compressor is needed. Most accessories are rated at 25% of actual CFM while running continuously. PROBLEM POSSIBLE CAUSES SOLUTIONS The regulator does not The regulator or its internal parts Replace the regulator. regulate the are dirty or damaged. pressure. The pressure is low or there is not enough air. There is moisture in the discharge air. The compressor overheats. There is a leak at one of the fittings. The tank drain valve is open. The air intake is restricted. Prolonged excessive use of air. There is a hole in the air hose. The tank leaks. The valve is leaking There is condensation in the air tank caused by a high level of atmospheric humidity or because the air compressor has not been running long enough. The ventilation is inadequate. Cooling surfaces are dirty. The valve is leaking. Check the fittings with soapy water. Tighten or reseal leaking fittings (apply plumber's tape on threads). Do not overtighten. Close the drain valve. Clean or replace the air filter element. Decrease the amount of air used. Check the air hose and replace it if necessary. Replace the tank immediately. Do not attempt to repair it. Check for worn parts and replace them if necessary. CAUTION: Always replace a damaged gauge before operating the unit again. Drain the air tank after each use. Drain the air tank more often in humid weather and use an air line filter. Relocate the compressor to an area with cool, dry and well-circulated air. Clean all cooling surfaces on the pump and the motor thoroughly. Replace worn parts and reassemble using new plumber's tape. TROUBLESHOOTING
12 model no contact us EXPLODED VIEW NO. DESCRIPTION QTY NO. DESCRIPTION QTY Drain valve 9 On/Off switch 2 Bolt 4 20 Air filter 3 Rubber foot 4 2 Switch retainer 4 Frame cap 4 22 Pump/Motor assembly 5 Tank 22- Capacitor,50 f 6 Handle sleeve 22-2 Capacitor,200 f 7 Panel 22-3 Fan 8 Nut 4 23 Bolt M5x0 2 9 Bolt 7 24 Lock washer 2 0 Tube 25 Front shroud Regulator 26 Cushion pad 4 2 Pressure gauge 2 27 Nut 4 3 Quick connector 2 28 Check valve 4 Self-tapping screw ST3.9x Transfer tube 5 Bolt M5x Power cord 6 Back shroud 3 Pressure switch 7 Bolt M8x Anchor nut 8 Washer Relief valve If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at PARTS LIST
13 model no contact us WARRANTY This Mastercraft product is guaranteed for a period of 3 years from the date of original retail purchase against defects in workmanship and materials, except for the following component: Component A: Accessories, which are guaranteed for a period of -year from the date of original retail purchase against defects in workmanship and materials. Subject to the conditions and limitations described below, this product, if returned to us with proof of purchase within the stated warranty period and if covered under this warranty, will be repaired or replaced (with the same model, or one of equal value or specification), at our option. We will bear the cost of any repair or replacement and any costs of labour relating thereto. These warranties are subject to the following conditions and limitations: A. A bill of sale verifying the purchase and purchase date must be provided; B. This warranty will not apply to any product or part thereof which is worn or broken or which has become inoperative due to abuse, misuse, accidental damage, neglect or lack of proper installation, operation or maintenance (as outlined in the applicable owner s manual or operating instructions) or which is being used for industrial, professional, commercial or rental purposes; C. This warranty will not apply to normal wear and tear or to expendable parts or accessories that may be supplied with the product which are expected to become inoperative or unusable after a reasonable period of use; D. This warranty will not apply to routine maintenance and consumable items such as, but not limited to, fuel, lubricants, vacuum bags, blades, belts, sandpaper, bits, fluids, tune-ups or adjustments; E. This warranty will not apply where damage is caused by repairs made or attempted by others (i.e. persons not authorized by the manufacturer); F. This warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished product (unless otherwise specified in writing); G. This warranty will not apply to any product or part thereof if any part from another manufacturer is installed therein or any repairs or alterations have been made or attempted by unauthorized persons; H. This warranty will not apply to normal deterioration of the exterior finish, such as, but not limited to, scratches, dents, paint chips, or to any corrosion or discolouring by heat, abrasive and chemical cleaners; I. This warranty will not apply to component parts sold by and identified as the product of another company, which shall be covered under the product manufacturer s warranty, if any. Additional Limitations This warranty applies only to the original purchaser and may not be transferred. Neither the retailer nor the manufacturer shall be liable for any other expense, loss or damage, including, without limitation, any indirect, incidental, consequential or exemplary damages arising in connection with the sale, use or inability to use this product. Notice to Consumer This warranty gives you specific legal rights, and you may have other rights, which may vary from province to province. The provisions contained in this warranty are not intended to limit, modify, take away from, disclaim or exclude any statutory warranties set forth in any applicable provincial or federal legislation. Made in China Imported by Mastercraft Canada Toronto, Canada M4S 2B8 WARRANTY
INSTRUCTION MANUAL 8 U.S. GALLON (30.3 L) AIR COMPRESSOR
INSTRUCTION MANUAL 8 U.S. GALLON (30.3 L) AIR COMPRESSOR 058-936-0 If any parts are missing or damaged, or if you have any questions, please call -800-689-9928. Read and understand this instruction manual
2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING
ITEM# AT01101 SKU# 207-1525 OPERATOR S MANUAL 1/3HP/2-GALLON 2 GAL AIR COMPRESSOR IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING Toll Free Helpline: 1-888-899-0146 Versions 01 TABLE OF CONTENTS SAFETY
AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.
2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
INSTRUCTION MANUAL AIR-POWERED STAPLER
INSTRUCTION MANUAL AIR-POWERED STAPLER 058-8132-2 2 QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 9 KEY PARTS DIAGRAM 10 IMPORTANT INFORMATION 11 13 TYPES OF FASTENERS 14 OPERATING INSTRUCTIONS
SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
DeVILBISS AIR POWER COMPANY. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART
DeVILBISS AIR POWER COMPANY OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART Model No. Horsepower SCFM @ 40 psig SCFM @ 90 psig Cut-In Cut-Out
AIR-POWERED RIGHT ANGLE DIE GRINDER
INSTRUCTION MANUAL AIR-POWERED RIGHT ANGLE DIE GRINDER 058-7713-6 2 QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 9 KEY PARTS DIAGRAM 10 IMPORTANT INFORMATION 11 13 OPERATING INSTRUCTIONS
200 PSI HIGH-FLOW AIR SOURCE KIT
200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
PC 1010 Electric Air Compressor
PC 1010 Electric Air Compressor Operating Instructions Warnings for the safe use of this compressor are included in this manual. TABLE OF CONTENTS INTRODUCTION... 3 SAFETY INSTRUCTIONS...3 INSPECTION...
accidents which arise due to non-observance of these instructions and the safety information herein.
3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
5 Gallon Air Compressor
5 Gallon Air Compressor 07-5 OPERATOR S MANUAL CAUTION: To Reduce The Risk Of Injury, User Must Read And Understand Operator s Manual. Save These Instructions For Future Reference. TABLE OF CONTENTS Table
8-gallon Air Compressor Kit
8-gallon Air Compressor Kit 58-7992-0 Instruction Manual For Parts, Service, Warranty or other Assistance, please Call 1-877-888-3872 Manual 58-7992 V 1.7 8 Gallon compressor Table of Contents Safety Guidelines
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank
120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions C US 2006, 2007 by Senco Products, Inc. Warnings for the safe use of this tool are included
100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13
100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please
Instruction manual. Pancake Compressor ESPAÑOL: PÁGINA 19 FRANÇAISE: PAGE 37 MODEL CPF23400P
ESPAÑOL: PÁGINA 19 FRANÇAISE: PAGE 37 Instruction manual Pancake Compressor MODEL CPF23400P To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT Please make certain
AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions
AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com
ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM
ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM PART NO. 10000 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13
24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please
LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight
Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)
Operating Manual Model 25200B/25202B Refrigerant Recovery Unit (Not for use in automotive R-134a applications) ROBINAIR Refrigerant Recovery Unit Model: 25200B /25202B Series Type of Equipment: Recovery
AIR INLINE METAL SHEAR
AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork
Budget Range Operators Handbook
Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk
480C DUAL PERFORMANCE VALUE PACK
(Pewter) PART NO. 48012 (Chrome) PART NO. 48032 (Stealth Black) PART NO. 48042 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
Instruction manual. Direct Drive Oil Lube Portable Air Compressor ESPAÑOL: PÁGINA 27 FRANÇAIS: PAGE 53. Model C3550
Instruction manual ESPAÑOL: PÁGINA 27 FRANÇAIS: PAGE 53 Model C3550 Direct Drive Oil Lube Portable Air Compressor To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT
2 Gallon, 100 PSI Oilless
2 Gallon, 100 PSI Oilless Air Compressor Model 47407 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
2 Gallon Oil Free Air Compressor
2 Gallon Oil Free Air Compressor Item# 22020 Owner s Manual DO NOT RETURN TO STORE Questions? Problems? Please call our customer help line: (800) 232-1195 M-F 8-5 CST Or by email: partsandservice@greatlakestec.com
Freedom8 ShoeBox Compressor Manual
Freedom8 ShoeBox Compressor Manual Warning!! This product is not a toy! Use or misuse can cause severe injury or death! Use only with adult supervision. This unit is only to be used with tanks, hoses and
SILENTAIRE TECHNOLOGY
SILENTAIRE TECHNOLOGY General User and Maintenance Instructions Thank you and congratulations on the purchase of your PANTHER, the leader in the industry of portable air compressors. The PANTHER is built
PC 1010 Electric Air Compressor
Questions? Comments? call SENCOíS toll-free Action-line: 1-888-222-8144 or e-mail: toolprof@senco.com PC 1010 Electric Air Compressor Senco Products, Inc. 8485 Broadwell Rd. Cincinnati, OH 45244 Operating
Model ASSEMBLY and OPERATING INSTRUCTIONS
QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,
CAP2000P-OF AIR COMPRESSOR COMPRESOR DE AIRE CAP2000P-OF COMPRESSEUR D AIR CAP2000P-OF
CAP2000P-OF AIR COMPRESSOR COMPRESOR DE AIRE CAP2000P-OF COMPRESSEUR D AIR CAP2000P-OF OPERATION and MAINTENANCE MANUAL MANUALES DE OPERACIÓN y MANTENIMIENTO LES MANUELS D UTILISATION et D ENTRETIEN BEFORE
accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
3 GAL OIL-FREE PANCAKE COMPRESSOR
3 GAL OIL-FREE PANCAKE COMPRESSOR 40502 Owner s Manual TOLL-FREE HELPLINE: -888-90WORKS (888.909.6757) www.greenworkstools.com Read all safety rules and instructions carefully before operating this tool.
5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
21 Gallon. Model Visit our website at:
21 Gallon Cast Iron VERTICAL Oil-lubricated AIR COMPRESSOR Model 94667 OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to
OILLESS AIR COMPRESSOR 135 PSI
OILLESS AIR COMPRESSOR 135 PSI Model 96087 Assembly And Operation Instructions Please note: Air Hose sold separately. Due to continuing improvements, actual product may differ slightly from the product
PC 2001 Electric Air Compressor
Questions? Comments? call SENCO S toll-free Action-line: 1-888-222-8144 or, e-mail: toolprof@senco.com PC 2001 Electric Air Compressor Operating Instructions Document #FN2001 Issued 5/30/A Warnings for
1 DRIVE INDUSTRIAL IMPACT WRENCH
1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight
Installation Instructions Air Compressor Part # 2780, 2781
Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil
AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE
625 Joyce Kilmer Avenue New Brunswick, New Jersey 08901 AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE Congratulations! You have purchased the finest specialty air compressor product in the world!
MD R a n g e O p e r a t o r s H a n d b o o k
MD R a n g e O p e r a t o r s H a n d b o o k Covering Models:- MD35/20 MD75/80 MD75/0 MD75/0V MD75/250 MD75/250V MD0/500 MD225/1000 BAMBI AIR COMPRESSORS LTD 2 Thimble Mill Lane Heartlands Birmingham
ULTRA QUIET & OIL FREE
ULTRA QUIET & OIL FREE AIR COMPRESSOR OwnER'S MAnUAL CALIFORnIA AIR TOOLS 10020 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon 2 Important Safety
MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION
MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION Jackco Transnational Inc. 202 South El Monte, CA 888-452-2526 www.jackco.com FOR YOUR SAFETY Read all instructions, warnings and cautions carefully. Follow all
RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]
RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.
Pressure Relief Valve Instruction Manual
CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:
Pancake Compressor. Instruction manual ESPAÑOL: PÁGINA 19 FRANÇAISE : PAGE 37 MODEL CPFAC2040P
ESPAÑOL: PÁGINA 19 FRANÇAISE : PAGE 37 Instruction manual Pancake Compressor MODEL CPFAC2040P To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT Please make certain
14" 10A ELECTRIC DETHATCHER
14" 10A ELECTRIC DETHATCHER 27022 Owner s Manual TOLL-FREE HELPLINE: 1-888-90WORKS (888.909.6757) Read all safety rules and instructions carefully before operating this tool. CONTENTS Contents... 2 Specifications...
PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
ATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
Model OPERATING INSTRUCTIONS. Due to continuing improvements, actual product may differ slightly from the product described herein.
2 GALLON 1.5 HP AIR COMPRESSOR Model 94724 OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,
IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS
1 / 2 COMPACT AIR TWIN HAMMER IMPACT WRENCH 94802 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
Oillube Single=Stage Portable Compressor
Oillube Single=Stage Portable Compressor IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model
T1-Titanium HVLP Siphon Feed Spray Gun
T1-Titanium HVLP Siphon Feed Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
IMPORTANT SAFETY INFORMATION
WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury
SC100V AIR COMPRESSOR
SC100V AIR COMPRESSOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. SPECIFICATION ITEM DATA Model SC100V Power 2.2 Kw / 3 HP Voltage 230 V Frequency
G92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:
Hotspotter Model WB-100 Professional Series Assembly, Testing & Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand-Held LP Torches for use with
ATD /8 x 50 Retractable Air Hose Reel Owner s Manual
ATD-31166 3/8 x 50 Retractable Air Hose Reel Owner s Manual Features Heavy-gauge, all-steel reel assembly 8-position ratchet mechanism locks reel at desired hose length 5-position adjustable roller outlet
AIR COMPRESSOR 3 Gallon / 1.5 Peak HP
Model #835408 AIR COMPRESSOR 3 Gallon / 1.5 Peak HP 226892 If you encounter any problems or difficulties, Do not return your compressor to the store! Please contact our toll-free customer service department
Setup Guide for your HVO Naked Drone
Setup Guide for your HVO 60 + 60 Naked Drone 1 The Big Picture 1. Choose The System Location 2. Get the Power Ready 3. Get an Approved Oxygen Regulator 4. Get the Tools You ll Need 5. Unpack the crate
Operating Manual. Model BAC-30RT30/BAC-30DC
Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100
453 Series Steam Heated Vaporizing Regulator
ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
AIR COMPRESSORS MODEL G8694 2HP / G HP / G8889 2HP INSTRUCTION MANUAL
WWW.GRIZZLY.COM AIR COMPRESSORS MODEL G8694 2HP / G8695 2.5HP / G8889 2HP INSTRUCTION MANUAL G8694 G8695 G8889 COPYRIGHT 1999 BY GRIZZLY INDUSTRIAL, INC. 1821 VALENCIA ST., BELLINGHAM, WA 98226 WARNING:
J Air and Water Kit Instructions Part# 02584
J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you
4 ANGLE GRINDER MODEL NO: CAT 52 PART
4 ANGLE GRINDER 4 ANGLE GRINDER MODEL NO: CAT 52 PART No: 3110685 OPERATION & MAINTENANCE INSTRUCTIONS 0807 Fig.1 SPECIFICATIONS Model:...CAG52 Part Number:...3110685 Rated Wheel...Capacity: 4 x 1/4 (type
HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)
Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to
1/2 in. AIR IMPACT WRENCH (TWIN HAMMER)
1/2 in. AIR IMPACT WRENCH (TWIN HAMMER) WARNING Read Operator s Manual. Do not operate equipment until you have read this Operator s Manual for Safety, Assembly/Operation and Maintenance Instructions.
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
OPERATION / / 1:1 RATIO TRITON / 3Z9305G Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure Related manuals....... 309304, Parts /....... 309303, Pump /.......
Operator: Save these instructions for future use!
INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
CUT OFF TOOL MODEL: CAT113
CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you
2.5 & 5.0 GALLON PRESSURE TANKS
2.5 & 5.0 GALLON PRESSURE TANKS Includes: MODEL 7025 MODEL 7026 MODEL 7027 MODEL 7028 2.5 Gallon Single Regulation (NON A.S.M.E.) 2.5 Gallon Dual Regulation (NON A.S.M.E.) 5.0 Gallon Single Regulation
PC 1010 Electric Air Compressor
Questions? Comments? call SENCO's toll-free Action-line: 1-800-543-4596 or e-mail: toolprof@senco.com PC 1010 Electric Air Compressor Senco Products, Inc. 8485 Broadwell Rd. Cincinnati, OH 45244 Operating
1/4 Air Ratchet Wrench
/4 Air Ratchet Wrench 92849 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 2005 by Harbor Freight Tools. All
BTFP02040 AIR COMPRESSOR OPERATION AND MAINTENANCE MANUAL
BTFP02040 AIR COMPRESSOR OPERATION AND MAINTENANCE MANUAL BEFORE OPERATING THIS COMPRESSOR, THE USER SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS. KEEP THESE INSTRUCTIONS
OILLESS AIR COMPRESSOR 8 GALLON CAPACITY
OILLESS AIR COMPRESSOR 8 GALLON CAPACITY Model 94355 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. TO PREVENT
Operator s Manual AFA-1, AFA-2, & AFP-1 Torch Kits
Operator s Manual AFA-1, AFA-2, & AFP-1 Torch Kits AFA-1 (50210) Torch kit AFA-2 (50211) Torch Kit AFP-1 (50212) Torch kit WARNING: Do not assemble, install, or operate this equipment without reading ALL
1/2 REVERSIBLE RATCHET. 1/2 REVERSIBLE RATCHET MODEL NO: CAT 22b + CAT 91 PART No: & OPERATION & MAINTENANCE INSTRUCTIONS
1/2 REVERSIBLE RATCHET 1/2 REVERSIBLE RATCHET MODEL NO: CAT 22b + CAT 91 PART No: 3110411 & 3110847 OPERATION & MAINTENANCE INSTRUCTIONS 0104 Fig.1 HAND-ARM VIBRATION Refer to notes on page 7 MODEL No:
20 Ton Air Over Hydraulic Jack
20 Ton Air Over Hydraulic Jack Model 95553 Assembly And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly
Zip-Tex 750 and Zip-Tex For Water-Based Materials Only Models: Zip-Tex 750, 6 Gallon 55 psi (3.79 bar) Maximum Fluid Working Pressure
Operation Interior Texture Sprayer Zip-Tex 750 and Zip-Tex 1000 309799C For Water-Based Materials Only Models: 246318 -Zip-Tex 750, 6 Gallon 55 psi (3.79 bar) Maximum Fluid Working Pressure 246319 - Zip-Tex
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
Inflatable Stand Up Paddle Board Manual
Inflatable Stand Up Paddle Board Manual V-Max AIR 12 6 Voyager AIR 11 6 Koa AIR 10 2 and 10 8 Heavy duty built in carrying handles Steel D Ring Built in Cargo Straps EVA Deck Pad High Pressure Air Valve
ANGLE DIE GRINDER SET
ANGLE DIE GRINDER SET MODEL NO: CAT65 PART NO: 3110725 OPERATING & MAINTENANCE INSTRUCTIONS GC0614 INTRODUCTION Thank you for purchasing this CLARKE Angle Die Grinder Set. Before attempting to use this
P245 PNEUMATIC FLOORING TOOL OPERATING INSTRUCTIONS
P245 PNEUMATIC FLOORING TOOL OPERATING INSTRUCTIONS WARNING Read these instructions thoroughly before using this tool and keep it handy for reference. Printed in Canada v140, 08/15 PRIMATECH PNEUMATIC
WARRIOR 30 & 60 AIR COMPRESSOR OPERATING & MAINTENANCE INSTRUCTIONS
O WARRIOR 30 & 60 AIR COMPRESSOR OPERATING & MAINTENANCE INSTRUCTIONS 0903 COMPRESSOR No. Description Qty Part No. No. Description Qty Part No. 1 Head Bolt 4 FN014002021 2 After Cooler 1 FN116117020 3
HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL
30230 Los Alamos Rd. Murrieta, CA 92563 800-279-5659 FAX 951-926-2334 TappingMachines.com HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL & OPERATING INSTRUCTIONS WARNING READ: Before using this product,
Operation and Maintenance Manual
Operation and Maintenance Manual Direct Drive Compressors IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this Instruction Manual prior to operation.
Back Pressure Regulator
Instructions Parts List STAINLESS STEEL, WATERBASE COMPATIBLE Back Pressure Regulator 308401E For use in circulating systems to provide regulated back pressure to spray gun(s) and to maintain proper system
80 GALLON INDUSTRIAL AIR COMPRESSOR OPERATOR'S MANUAL
80 GALLON INDUSTRIAL AIR COMPRESSOR OPERATOR'S MANUAL CAUTION RISK OF INJURY! READ ENTIRE MANUAL BEFORE OPERATING! THIS MANUAL IS AN IMPORTANT PART OF THE AIR COMPRESSOR AND MUST REMAIN WITH THIS UNIT!
U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
Parts and Owners Manual
Parts and Owners Manual MOWER MODEL: SERIAL: ENGINE MODEL & HP: DATE PURCHASED: PURCHASED FROM: You must receive special training from the dealer before operating this mower. 9/30/2005 Commercial Mower