1 Stone Container 987 Auger Packer Manual SAFETY INSTALLATION OPERATION MAINTENANCE, Ltd. (512) Phone (512) Fax 1
2 Table of Contents Topic Reconditioned Machine Information Page Insert Chapter I: Safety in Operation.. 3 Chapter II: Before Operating Equipment 4 Chapter III: Caution During Operation... 4 Chapter IV: Installation 6 Chapter V: Lubrication Instructions... 7 Chapter VI: Trouble Check List for Auger Packers.. 9 Chapter VII: Principal of Operation 10 Chapter VIII: Sequence of Operation.. 10 A. Phase One 10 B. Phase Two 11 Chapter IX: Start Up Instructions and Adjustments.. 12 Chapter X: General Maintenance. 12 Chapter XI: Parts Pages. 14 Chapter XII: Electrical Schematics 22 2
3 I. Safety in Operation This manual has been prepared to assist you with your, Ltd. bag packaging equipment. The text contains instructions for installation and operation of your packing equipment, as well as directions for adjustment and maintenance. Following the text is the reference section which contains drawings; bills of materials, recommended spare parts, manufacturers' bulletins and any other information necessary to the successful operation of your equipment. If further information or assistance is needed, please contact us at: Choice Bagging Equipment, Ltd., 2561 US Hwy 95, Taylor, TX , Phone: (512) , or Fax: (512) , or IMPORTANT NOTICE READ THIS MANUAL COMPLETELY before installing, starting-up, or operating this equipment. Be certain all personnel concerned with this machinery are fully alerted to the possible HAZARDS of the equipment and its utilities (electrical and pneumatic) before any operation is allowed., Ltd. cannot emphasize enough the importance of good safety practices in the use of this equipment. Sound engineering and design practices have been applied to minimize the possibility of accidents. However, while using equipment of this type, good judgment and extreme caution are necessary on the part of all personnel. The purpose of this section is to alert operating and maintenance personnel to the possible dangers of this type of equipment. Serious injury and/or equipment damage could result from not heeding these safety precautions. 3
4 II. Before Operating Equipment Any personnel working directly with or on this equipment should read this material before proceeding with equipment use. Electricians should familiarize themselves with the electrical drawings before initial start-up of equipment. Other appropriate operating and maintenance personnel should familiarize themselves with mechanical layout and general arrangement drawings before start-up of equipment. These tips are important for safe operation: 1. As you uncrate the shipped machine, check carefully for any damage, loose connections, wires that are loose, etc. Be careful to note any discrepancies you find and BEFORE you start the machine call Choice Bagging Equipment to make sure the situation you see is or is not critical in nature. If severe damage has occurred, verify the damage with written reports AND pictures, call and call the trucking company or transportation provide. 2. Determine location of all emergency switches. 3. Be sure all guards are in place and observe all warning signs. 4. Check oil levels in all motors. 5. Be sure all electrical equipment is free of any accumulation of water. 6. Be sure all personnel are clear of operating mechanisms before connection air. 7. Never start equipment without first checking for loose objects, trash, dropped nuts and bolts, or other foreign items. All persons in the immediate area of the equipment should be alert to danger prior to starting III. Caution During Operation 1. Observe extreme caution when switches are turned on. Operation may in automatically after a time delay. 2. DO NOT open junction boxes or control panels unless you are a qualified technician. Be sure POWER IF OFF. Except when electricians are performing maintenance, electrical enclosures and junction boxes should REMAIN SECURELY CLOSED. 4
5 3. STOP machine and disconnect power supply before servicing or repairing. Maintenance and adjustments must be performed with all power supply disconnected unless otherwise specified in this manual. 4. READ COMPLETELY any additional manual included in this manual that pertains to your specific controller. 5. DO NOT attempt to defeat any safety switches. Serious injury could result. 6. While machine control power is ON, do not activate limit switches manually. Serious injury and/or machine damage could result. Disable machine before attempting any maintenance or manual testing of components. 7. Gear motors will get warm to the touch and should not cause concern for equipment reliability and operation. A temperature rise is normal per new NEMA specifications. 8. If additional wire runs are added to any junction box or control panel, wiring practice should be such as to maintain prevailing electrical hazard classification. 9. High-pressure air systems are dangerous. DO NOT service or troubleshoot systems with air supply on. Be sure to bleed off any trapped air before working on components since it is possible to have high pressures trapped in airlines and cylinders, etc. 10. Keep fingers, hands, feet, clothing, etc., out of the path of pneumatically operated components. 11. Safety glasses should be worn in equipment area. 12. Follow the safety regulations for your plant. ALWAYS USE GOOD JUDGEMENT. NOTE: Before you begin production AND as you continue working daily with the machine, these points are recommended to observe for continuous service. Service parts such as belts, stuffing box material, bearings, gears, fill spouts, etc. are available for replacement and stock supplies through. 5
6 NOTE: After uncrating the packer, a check should be made to see that all items ordered have been received and that all equipment are in good order. Any damages incurred in the shipment process should be reported immediately to the shipper and the carrier. The majority of packers are shipped intact with the exceptions of large attachments. Packers should all have the scales and beams and movable parts secured to prevent damage. IV. Installation 1. Securing the Packer Secure the packer firmly in place with 1/2' bolts through the mounting holes in the packer base. Refer to the basic dimensional outline drawing in the manual. The foundation should be solid and free from vibrations which would be transmitted to the scale mechanism of the packer. 2. Leveling the Packer Place the packer in its operating location and bring it level by plumbing the front legs. Any deviation from plumb between the two legs should be compromised half way. This will result in plumb center lines. This step is important for the machine must be level for the scale to function properly. 3. Connection to Supply Hopper Connection to the supply hopper should be made with a flexible material in order to minimize transmission of vibration to the packer. Neoprene, rubber, or a 12- ounce canvas duck sock make a good connection material. 4. Connection to Power Source Punch a conduit hole in the electrical cabinet at a point convenient to connect the plant electrical power. Connect he power source of the proper voltage to the disconnect terminals in the packer. CAUTION: All Stoker packers are pre-wired to the customer's voltage specifications prior to leaving the factory. However, on all packers a check should be made to insure that the power source voltage corresponds to the wiring in the machine. All Stoker auger packers (except the Model VP Volumetric) are equipped with a transformer to provide 110 volt power to the control circuit. A visual inspection of 6
7 the transformer hookup will insure that the packer is wired to correspond to the power source voltage. On Volumetric Packers, the voltage of the coil in the starter will identify the voltage at which the machine is wired. 5. Bag Rest and Settler Height Adjustment Because of the wide variety and types of valve bags available, the bag rest adjustment should best be done by trial and error. The best indication for correct adjustment can be made after the bag has been filled. Prior to removing the filled bag from the filling spout, check to insure that the weight of the bag is resting on the bag saddle and not hanging from the packer spout. The top of the bag should also be well filled out and not taper down directly from the spout. The paper at the top of the bag should not be under tension. Incorrect bag saddle adjustment is a common cause for off-weights and problems with consistent measurements. Care should be taken that the bag saddle position is high enough to allow the bag to fill out properly at the end of the filling cycle, especially in the upper portion of the bags. If the saddle is not high enough, the bag capacity may be greatly reduced. V. Lubrication Instructions All bearings are lubricated prior to leaving the factory. Listed below are the lubrication locations and a chart for finding all major types of lubricants needed. It is preferable that the bearings be greased while the packer is running to prevent breaking the seals. If the packer is stopped, while greasing, care should be taken to pump the grease in very slowly. Avoid over greasing in all cases. 7
8 1. Agitator ball bearings: *Grease approximately once a month while machine is running 2. Dashpot: *Check periodically 3. Auger ball bearings: *Grease while machine is running 4. Wool packing *Check periodically 8
9 5. Lubricator *Check monthly WARNING: Do not use motor oils that have a detergent additive in the lubrication process. VI. Trouble Check List for Auger Packers If the auger packer is giving weight variation or filling speed is reduced, check through the following list. If the packer is vibrating excessively, determine the source of the vibration by checking the causes listed below: 1. Check the "V" belt sheaves for looseness 2. Check "V" belt adjustment to be sure both belts are adjusted for the correct tension. 3. Check to be sure that the auger is straight and running concentric in the spout. A bent auger can be detected by doing the following: a. Empty the material from the packer b. Start the packer and observe the end of the auger for vibration 4. Incorrect bag size is a common cause of off weights. If the bag is too small it will cause back pressure. This back pressure will delay the cut off and cause over weights. Try a few bags at 75% of the normal weight packed into the bag. Good weights at this reduced quantity filled indicate the bag is too small. 5 The rubber dust seal which covers cone-spout gap must be flexible. 6. If the bag rest is not properly positioned it can cause erratic bag filling and off weights. 9
10 7. Check the weighing mechanism to be sure that it is moving freely. Object resting against or touching the weighing mechanism during the filling cycle will cause variation in weights. 8. If the packer is equipped with a dust hood remove the vacuum hose that connect it to the dust collection equipment. Run a few bags of material and check weights. If the bags now hold a uniform weight the flexible connection between the dust hood and the dust collection needs to be made more flexible. VII. Principal of Operation An auger feed assembly is the main feature of the Stone Container 987 Auger Packer. The auger housing receives bulk product from the surge bin and supplies a steady stream into the bag utilizing a 2" - 3" OD material delivery screw to convey product from the housing into the bag. In order to provide a solid cutoff, the auger briefly reverses to stop material flow from the auger housing. High-pressure air (80 PSI) operates two separate control sequences: Start and Stop. On actuation of Start signal by the operator, a auger transfers material from the hopper and feeds to the bag. The auger reverses when the material in the bag reaches a predetermined weight. Bags are weighed during the filling operation on a unit consisting of bag support frame and filling tube mounted on the front of a scale beam at flexure assembly. Filled bags are discharged automatically when the machine is equipped with an automatic discharge bag chair arrangement. All of the operation activity for each bag filling cycle takes place in a matter of seconds. This packing speed is important not only to achieve high production rates, but also for proper function of the Stone Container 987 Packer. VIII. Sequence of Operation A typical "two-phase" operational sequence is used for filling a bag. The sequence below describes the optional timed powered discharge and bag sealer. A. Phase One: Phase One is the condition in effect at the end of the filling cycle. After actuation of the Stop (or Scale) signal the following sequences occur: 10
11 The auger spins forward and conveys product from the Agitator or V-Hopper, through the auger housing and through the fill tube into the bag. The motor drive assembly cuts off, then briefly reverses and the auger material feed assembly stops the flow of material from the auger housing into the bag. The bag clamp is released and the bag is removed from the machine. Since the material flows by gravity into the machine, it is continuously recharged. With the optional features shown on the schematic, the valve sealer deflates. This can be timed to ensure material stabilization into the bag. The powered discharge bag chair tilts to discharge the filled bag at the end of the sealer deflation. The timing of these features is one with specially designed pneumatic controls. During Phase One, the operator also places an empty bag on the filling tube after discharge of the previous bag. B. Phase Two Phase Two is the condition in effect during the filling cycle. After actuation of the start signal the following conditions occur: 1. The air operated bag clamp secures the bag to the filling tube. 2. The bag chair retracts to a level position. 3. The bag sealer inflates inside the valve of the bag. 4. The drive assembly is activated by the motor controls which spin the auger assembly and directs product flow from the housing, through the fill spout and into the bag. 5. The material is packed into the bag until the desired net weight is reached. 6. When the bag comes to weight, the scale beam trips the Stop circuit and the condition in Phase One is in effect. 7. If the packer is equipped with the optional automatic starting device, the start signal is obtained automatically when the bag is placed on the filling tube and contacts the starter level. 11
12 IX. Start up Instructions and Adjustments The Stone Container 987 is an automatic packer. The operator is required to put an empty bag on the filling spout and press the Start pushbutton (Green) button after the empty bag is in place. The bag is then filled and weighed automatically and, when equipped with the powered bag chair option, the bag is discharged automatically. If for any reason it is desired to interrupt the filling operation in the middle of a cycle, a Stop pushbutton (Red) is provided. It is recommended that the following adjustments be made to the packer before any material is delivered to the receiving hopper. Make sure all personnel are clear from the machine and at a safe distance. 1. Open manual valve for incoming high-pressure air. 2. Adjust the pressure regulator to 80 PSI with the power OFF. 3. Place an empty bag on the filling tube. Press Start Pushbutton. Note: Components should now be in Phase Two Operation. 4. Adjust the bag seal pressure to 3 PSI (optional equipment). The bag seal should expand just enough to secure the valve of the bag. Note: Excessive pressure may cause damage to the bag seal and tear the bag. Further adjustment may be required during actual packing operation. 5. Press the Stop pushbutton. Note: Components should now be in Phase One Operation. X. General Maintenance Stone Container Packers are designed so they can be operated and maintained by the user. It is time well spent for the operator and maintenance staff to study and thoroughly understand the function and working relationship of each part before any adjustment or maintenance is undertaken. 12
13 It is also highly recommended to institute a preventative maintenance program. We suggest that the following procedures be done at regular intervals: * Before operation make sure there is oil in the agitator and gear reducer if applicable and all bearings are greased. Grease bearings once a week. * Clean off the equipment * Check all operating parts for freedom and ease of operation * Check beam motion and front plate freedom. These parts must be free and unrestricted for accurate weighing. * Check the auger screw alignment. It must be centered in the spout. Warping or bending, movement, or noise are indications of problems. * Check the "V" belts for tension and wear * Check the Model "B" settler, if supplied, to see that it is not transmitting vibration to the packer. * Check the scale beam cutoff point. * Check fill spouts for nicks and chips from daily usage. * Check the isolator rubber tubing for wear. * Stuffing boxes should be maintained. Make sure stuffing material is replaced and re-packed tightly every couple of months depending on the dust quality of the product. 13
14 Parts Pages 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 Electrical Schematics 22
23 23
MHE Model 2010 Air Packer Manual
Choice Bagging Equipment, Ltd. 2561 Hwy 95, P.O. Box 81 Taylor, Texas 76574 P# (512)352-3694 F# 3648 www.valvebagfiller.com MHE Model 2010 Air Packer Manual SAFETY INSTALLATION OPERATION MAINTENANCE Choice
More informationINSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT
INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 405-282-8105 www.autoquip.com Item # 830ABS Version 1.0 07/2001
More informationCLARKES ERO FEEDER MANUAL
CLARKES ERO FEEDER MANUAL It is the sole responsibility of the Owner and/or the Responsible Supervising Operators of this equipment to properly instruct their employees, either direct or contact, in the
More informationPROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road
PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves
More informationVTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS
VTL VFL VCL Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS Low Profile Series VL units should be rigged and installed as outlined in this bulletin. These procedures should be thoroughly reviewed
More informationDIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D
OPERATOR'S MANUAL DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D LUBRICATE DAILY: A. Gears inside gear housing at chuck shaft (1) Oil B. Seam rolls and cam rolls (4) - Oil C. Seam roll levers through gear
More informationDuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)
Purpose: To provide the minimum requirements for the lockout or tagout of energy isolating devices whenever work is performed or servicing is done on County of DuPage machinery, equipment, vehicles and
More informationNew AQF Filter Polymer Filtration System
New AQF Filter Polymer Filtration System Operator Manual Covering Serial Number 20002001 onwards February 2011 Index Disclaimer notice...3 Introduction...4 Important safety notices...5 Getting started...6
More informationO P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer
O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer TABLE OF CONTENTS I. SPECIFICATIONS...3. II. SAFETY INSTRUCTIONS...4. III. INSTALLATION...5. IV. SET-UP...6. V. SYSTEM OPERATION...9.
More informationPart IV: Troubleshooting
Part IV: Troubleshooting Excessive Oil Carryover Pump-Up Time Test Excessive oil carryover can have adverse effects on the performance of pneumatic climate control systems. Although some oil entrainment
More information400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO
400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand
More informationMoveRoll Conveyor Operating and Maintenance Manual
MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.
More informationApex Evaporator Manual
Apex Evaporator Manual Table of Contents I. Handling/Transportation of Apex II. Placing the evaporator III. Connecting Power to the control Panel IV. Placing the control panel and weather station V. Attaching
More informationNB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
More informationFABRICATED ROTARY AIRLOCK
FABRICATED ROTARY AIRLOCK INSTRUCTION, OPERATIONS & MAINTENANCE MANUAL CLEAN AIR MANAGEMENT COMPANY, INC. 8224 Nieman Road i Lenexa, Kansas 66214 Phone: 913-831-0740 Fax: 913-831-9271 TABLE OF CONTENTS
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationLockout. HealthandSafetyOntario.ca. What is Lockout? How is a Lockout Done? Why is a Lockout Necessary?
What is Lockout? Lockout means to physically neutralize all energies in a piece of equipment before beginning any maintenance or repair work. Lockouts generally involve: Stopping all energy flows (for
More informationAIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL
00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationAUTOMATED INDUSTRIAL MACHINE, INC
The Pneumatic Toggle Press Innovators. Since 1947. AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION 347 Farnum Pike Smithfield, RI, USA 02917 401-232-1710 www.joraco.com Installation, Operation and
More informationINSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May
INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May 2015 98-0520 S/N 2001 N. Indianwood Ave. Tulsa, Oklahoma 74012 U.S.A. TEL: (918) 250-7200 FAX: (918) 459-0165 E-mail: chandler.sales@ametek.com
More informationIndex Table. Model 794. Installation, Operating and Maintenance Instructions
CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009
More information42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)
42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor
More informationTire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies
Tire Inflation Cage Kit 85608214 For servicing only single piece automotive, and most light truck tire/wheel assemblies This is a supplement to your operating manual and covers the setup and use of the
More informationInstallation and Service Manual
An Actuant Company Installation and Service Manual Heavy Duty Hydraulic Stabilization Legs CONTENTS Part # 3010003129 REV 0D Section Page 1.0 Receiving Instructions 2 2.0 Safety Issues 2 3.0 Hydraulic
More informationMODEL 840 AIR HYDRAULIC PUMP INSTRUCTION
MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION Jackco Transnational Inc. 202 South El Monte, CA 888-452-2526 www.jackco.com FOR YOUR SAFETY Read all instructions, warnings and cautions carefully. Follow all
More informationUSER MANUAL. MACMAG magnetic separator MHK MHF
USER MANUAL MACMAG magnetic separator MHK MHF Important Read the safety precautions before use. Thank you for your purchase. This user manual contains important information on avoiding damage and personal
More informationRARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
More informationFXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS
FXT FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS FXT Cooling Towers should be rigged and assembled as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the actual
More information444C DUAL PERFORMANCE VALUE PACK
(Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL
More information30T A/Manual Hydraulic Shop Press
30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationRASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH
SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationMODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR
MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and
More informationPF30 Inspection & Maintenance Manual
PF30 Inspection & Maintenance Manual Version 1.4 (September 2011) 1 Contents 1. Warning!!!!!!!!!! 3 2. Terminology! Figure 1: POWERFAN PF30 and Drope!!!! 4! Figure 2: POWERFAN PF30 with belt guard retracted!!
More informationOPERATION and MAINTENANCE Guide
Catalog No. AIR1000 Winch and Hoist OPERATION and MAINTENANCE Guide Cat. No. AIR1000 1250 Lb. Single Line Pull READ THIS BEFORE OPERATING UNIT INSTALLATION: Mount on clean, flat surface. Use 1/2" mounting
More informationNGP-250/500 Nitrogen Generator Quick Start Guide
NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
More information/ FLT-M Quick Clean Rotary Airlock Valve Operators Manual. Kice Industries, Inc. RAV-M RAV-M
1 Quick Clean Rotary Airlock Valve Operators Manual Kice Industries, Inc. RAV-M04-0000 RAV-M04-0000 2 INTRODUCTION When you purchased your new Kice equipment, you bought a dependable and quality-built
More informationPneumatic Controls, Air Settings, Hydraulic adjustments on; Models 22HF, 16HF & 1600 machines
Knowledge Base Article Type: Instructions Pneumatic Controls, Air Settings, Hydraulic adjustments on; Models 22HF, 16HF & 1600 machines Description: Instruction sheet on how to make proper pneumatic air
More information20 Ton SD Shop Press Operating Instructions
20 Ton SD Shop Press Operating Instructions MODEL NO. 850SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential
More informationInstallation, Operation, & Maintenance Manual
Installation, Operation, & Maintenance Manual CAMCORP Fabricated Airlocks Square & Round Sizes 8 to 30 Unique Design & Engineering Approaches for Industrial Applications Safety Recommendations... 1-1 Receiving
More informationParts and Owners Manual
Parts and Owners Manual MOWER MODEL: SERIAL: ENGINE MODEL & HP: DATE PURCHASED: PURCHASED FROM: You must receive special training from the dealer before operating this mower. 9/30/2005 Commercial Mower
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome
More information170-SJ Feed UnitTM 470-SJ Feed UnitTM
SPONGE-JET 170-SJ Feed UnitTM 470-SJ Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet 170-SJ / 470-SJ User Manual - REV
More informationMAINTENANCE RECOMMENDATIONS
MAINTENANCE RECOMMENDATIONS COOLING SYSTEM: Very high secondary currents are developed in resistance welding equipment. This, coupled with compact design, high upset temperatures, and fast cycle times,
More informationConstant Pressure Crude Oil Container Model CPCCP
Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a
More information15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL
15ME-014 E INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV URL http://www.kemel.com CONTENTS [A] Installation [B] Piping [C] Inspection [D] Handling [E] Parts replacement intervals [F] Handling check
More informationP5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All
More information400C & 450C DUAL PERFORMANCE VALUE PACKS
(Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before
More informationOverspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)
Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1) Instructions for installation and operation 113 OG Моment 250 MR 115 OG Moment 250 MRL Overspeed
More information3/8" Dr. Air Butterfly Impact Wrench
8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More informationBUTTERFLY VALVES Series 800
BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized
More information100C Air Compressor Kit
10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is
More informationEnergy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:
Energy Control Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: 905.577.0303 cell: 905.977.0210 consultant@staffaid.ca www.staffaid.com Safety, Energy Control, Power Lockout & Function Test Procedures
More information75 Ton SD Shop Press Operating Instructions
75 Ton SD Shop Press Operating Instructions MODEL NO. 856SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential
More informationModel: 43T. Bermad Pressure Relief Valve
Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment
More information170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH
SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More information420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO
420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this
More informationDBML-60/80 Squeeze Tool
DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs
More informationRhinoPro Cartridge Gun Manual
RhinoPro Cartridge Gun Manual RhinoPro Cartridge Gun 1500 with 750ml cartridges Table of Contents Application Instructions......................................... 1 Operating Instructions..........................................
More informationLockout Tagout Policy
Office of Environmental Health & Safety www.moreheadstate.edu/ehs 606-783-2584 Lockout Tagout Policy PURPOSE To establish procedures for the de-energization and isolation of energy sources or the lockout
More informationModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)
UP P n e u m a t i c ModelsEZU-15 & EZU-15-R BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) 390-0055 (800) 231-3187 Table of Contents GETTING STARTED......................................
More information450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS
More informationLIFTING MAGNETS ERIEZ MAGNETICS
MJ-2300E Installation, Operation and Maintenance Instructions LIFTING MAGNETS ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, P.O. BOX 10608, ERIE, PA 16514 0608 U.S.A. WORLD AUTHORITY IN ADVANCED TECHNOLOGY
More informationAPPS-160 Gen 2 User Manual
APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com
More informationBOEING AIRCRAFT WEIGH WORKSHEET
WEIGHING FACILITIES AND EQUIPMENT ITEM MECH INSP The airplane should be weighed inside a closed facility that will: Exclude all wind and drafts. Permit shutdown of air conditioning during the weighing
More informationUniversal Valve Company Inc
Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal
More informationMisaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii
Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6
More informationUniversal Valve Company Inc
1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Universal Air Towers Please read closely to identify the components that are
More informationOperator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No
Operator s Manual with Maintenance Schedule Fourth Edition Second Printing Part No. 82297 Operator s Manual Fourth Edition Second Printing Important Read, understand and obey these safety rules and operating
More informationTEM# Air Hammer Combo USER'S MANUAL
Air Tools TEM# 40 Air Hammer Combo USER'S MANUAL Read carefully and understand RULES FOR SAFE OPERATION and instructions before operating. Failure to follow the safety rules and other basic safety precautions
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationicreasepro Creaser Operators Manual
6-2013 Version 3.0 icreasepro Creaser Operators Manual WWW.MBMCORP.COM 800-223-2508 TABLE OF CONTENTS SPECIFICATIONS.1a SAFETY PROCEDURES/CARE & MAINTENANCE..1b COMPONENT IDENTIFICATION 2 TOUCH SCREEN
More informationBray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual
Bray/ VAAS Knife Gate Valve 770/780 Series Operations and Maintenance Manual Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 2 Commissioning
More informationWPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE
PACIFIC LIQUID & AIR SYSTEMS WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE IN THE BEGINNING Before installing or operating this system, familiarize yourself with these instructions. You should
More informationAUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE
AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION Installation, Operation and Maintenance Hydro-Pneumatic Series Bench Presses IMPORTANT It is the responsibility of the employer/purchaser to provide
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationOperating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL
Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents
More informationCS150 CAP STAPLER OWNER S MANUAL
Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER
More informationSweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.
MAGUIRE PRODUCTS INC. SW SERIES SWEEPERS For SW Series Sweeper Models: SW-4815 SW-4820 SW-4825 Sweeper Dual Control Automatic Sweeper Switching System INSTRUCTION AND OPERATION MANUAL Copyright Maguire
More information450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing
More informationAir Tractor Preventative Maintenance Manual And Troubleshooting
1.0 Overview This maintenance schedule will assist in the maintenance and troubleshooting procedures for the Unified Industries Air Tractor. The first portion of this section details the general maintenance
More informationCONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in
CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in this instruction manual. 1 CONTENTS 3. Safety Precautions
More informationSqueegee Unit for MRS Multi-Recovery System
En Operating Instructions Squeegee Unit for MRS Multi-Recovery System Translation of the original operating instructions Squeegee - MRS Table of Contents Safety Recommendations Technical Data - MRS Booth
More informationOPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks
OPERATION, INSTALLATION, & MAINTENANCE MANUAL for Aircon Flex-air AN Airlocks Aircon Corporation P.O. Box 80446 2873 Chelsea Avenue Memphis, TN 38108-0446 Telephone: (901) 452-0230 FAX: (901) 452-0750
More informationMAYHEM MAYHEM OWNERS MANUAL. Paintball Guns International. Manufactured by
MAYHEM MAYHEM OWNERS MANUAL Manufactured by Paintball Guns International Table of Contents Specifications...................... 2 Parts diagram and Listing............. 3 Description of Marker Operation.......
More information6146XX-X OPEN STYLE HOSE REELS
OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE 6146XX-XXX OPEN STYLE HOSE REELS LOW, MEDIUM & HIGH PRESSURE (FOR AIR, WATER & PETROLEUM PRODUCTS) 6146XX-X RELEASED: 2-5-90 REVISED:
More informationREVERSIBLE AIR DRILL
REVERSIBLE AIR DRILL MODEL NO: CAT87 PART NO: 3110835 OPERATING & MAINTENANCE INSTRUCTIONS GC0613 INTRODUCTION Thank you for purchasing this CLARKE Reversible Air Drill Before attempting to use this product,
More information35 TON HYDRAULIC PUNCH WARNING
OPERATORS GUIDE REL-35T-PNC 35 TON HYDRAULIC PUNCH NOTICE Sizes, weights and tool specifications listed in this manual are subject to change without notice. Please consult factory for information and updates.
More informationREV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI
REV0709 Parts List Hydraulic Cylinder Model 10312 MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER Max. Capacity: 55.2 Tons at 10,000 PSI REV0709 Item No. Part No. No. Req d Description 1 10606
More informationMini Pod Press. #78H-M2 Mini Pod Press Manual-R1
Mini Pod Press Model - #78H-M2 SN - Year - JLT Clamps 108 Parker Ave. Poughkeepsie, NY 12601 Tel: (800) 901-8037 Fax: (845) 452-0764 E-mail: clampguys@jltclamps.com Web: http://www.jltclamps.com TABLE
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationUser Manual GRI- 1500Li
User Manual GRI- 1500Li Your Cart Tek caddy cart was thoroughly quality control checked and road tested before being shipped to your address. We do everything possible to assure that your caddy is in perfect
More informationRT3 CAP NAILER OWNER S MANUAL Operation Safety Maintenance Warranty! www.stingerworld.com PLEASE READ! This manual contains important information about product safety. REV 09/14 WELCOME TO STINGER Congratulations
More informationLOCKOUT/TAGOUT PROGRAM
0 Appendix C OCCUPATIONAL SAFETY AND HEALTH PROGRAM LOCKOUT/TAGOUT PROGRAM Hazardous Energy Control Lockout/Tagout Program TABLE OF CONTENTS Section Page I. Purpose and Scope. 1 II. Definitions 1 III.