Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N

Size: px
Start display at page:

Download "Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N"

Transcription

1 Landmark Veterinary Anesthesia Systems Operator s Manual P/N

2 Notice This is a Vetland Medical Sales and Services, L.L.C. publication which is protected by copyright. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Vetland. The information contained in this manual is subject to change without notice. Comments As part of our continuing effort to maintain the highest standards of quality in our manuals, we ask for your comments on this manual s accuracy, organization, clarity, and usefulness. Please send any comments by mail or to the address below: Address Vetland Medical Sales and Services, L.L.C Holloway Road Louisville, Kentucky U.S.A. Toll Free Phone: Fax: Website: info@vetlandmedical.com Landmark TM is a trademark of Vetland Medical Sales and Services, L.L.C. Cavicide is a registered trademark of Metrex Litholyme TM is a trademark of Allied Healthcare Products, Inc. Vetland, 2012, 2013, 2014, 2015, 2016, 2017 ii P/N

3 TABLE OF CONTENTS 1 INTRODUCTION Overview System Safety General Description Facility Requirements System Dimensions Basic System Features Description of Landmark Features SAFETY Overview Intended Use Description of Safety Symbols Basic Safety Precautions and Practices Patient and Operator Safety Preventing System and Facility Damage Facility Environmental Health Halothane Precautions System Malfunction Emergency Shutdown Moving a Stand-mounted Landmark System UNPACKING AND ASSEMBLY Overview Unpacking the System Assembling the System Stand Mount Assembling the System Wall Mount SYSTEM SETUP Overview Materials and Supplies Initial System Preparation Setting Up the System Filling the Anesthetic Vaporizers Funnel Fill P/N iii

4 Filling the Anesthetic Vaporizers Key Fill Connecting the Breathing Circuit Rebreathing Circuit Installation Non-rebreathing Circuit Installation OPERATION Overview Pre-use Checkout Inspiratory Pressure Adjustment Rebreathing Circuit vs. Non-rebreathing Circuit Using the Oxygen Flush Button Anesthetic Vaporizer Post-anesthesia Procedure TROUBLESHOOTING Overview Safety Machine Status Record Keeping Problem Solution Matrix System Pressure Leak Test F-circuit Method System Pressure Leak Test Squeeze Bulb Method MAINTENANCE Overview Safety Annual Inspection Machine Status Record Keeping Parts and Materials Cleaning the Equipment Required Materials and Supplies Disposition of Breathing Circuit Components Weekly Maintenance Draining the Vaporizer Funnel Fill Vaporizer iv Table of Contents

5 Key Fill Vaporizer Preparing a Vaporizer for Transport Preparing a Vaporizer for Transport Post-Maintenance Checkout Preparing the System for Storage PRODUCT INFORMATION Product Warranty Payment Terms Shipping Returned Goods Policy Limitation of Liability USEFUL INFORMATION Overview Pressure Equivalents Pressure Unit Conversions Monitored Anesthesia Care (MAC) Anesthetic Levels Miscellaneous Information Definition of Terms REPLACEMENT PARTS AND ACCESSORIES Overview Replaceable Materials and Accessories Exploded View Drawings P/N v

6 Table of Figures Figure 1-1 Landmark System Flow Diagram Figure 1-2 Dimensions - Landmark VSA-2100 Standard Floor Model Figure 1-3 Dimensions - Landmark VDA-4100 Double Wide Floor Model Figure 1-4 Dimensions - Landmark VTAA-1100 Table Top System Figure 1-5 System Features (VSA-2100) Figure 1-6 Doublewide System Features (VDA-4100) Figure 1-7 RTA-0011 Table Top Non-Rebreathing System Figure 1-8 VWA-3100 Wall Mount Figure 1-9 Dimensions - Landmark VTAA-1100 Table Top System Figure 2-1 Moving a Stand-mounted Landmark Machine Figure 3-1 Assembling a Stand Mount System Figure 3-2 Assembling the Landmark Wall Mount Figure 4-1 Installing O 2 Hose and Absorber Canister Figure 4-2 Filling the Vaporizer (Drager) Funnel Fill Figure 4-3 Filling the Vaporizer (Drager) Key Fill Figure 4-4 Rebreathing Circuit (Universal F-Circuit) Connections Figure 4-5 Non-Rebreathing Circuit (Modified Jackson Rees) Connections Figure 5-1 Valve Test Setup Figure 6-1 Pressure Test Setup Figure 6-2 Pressure Test Setup Figure 7-1 Inspiration/Expiration Valve Assembly (Exploded View) Figure 7-2 Draining the Vaporizer (Funnel Fill) Figure 7-3 Draining the Vaporizer (Key Fill) Figure 7-4 Landmark Standard - Back Cover Removed Figure 7-5 Removing the Vaporizer Figure 10-1 VSA-2100 Floor Model Figure 10-2 VTA-1100 Table Top Machine Figure 10-3 VDA-4100 Doublewide Machine Figure A Frame Assembly Figure A Gauge Assembly Figure A Back Panel Assembly Figure A Pole Assembly Figure A Oxygen Flowmeter Assembly Figure A APL / Pop-off Valve Assembly Figure A Manifold Block Assembly Figure A Absorber Canister Assembly Figure A Flush Valve Assembly Figure A Inspiratory Expiratory Valve Assembly Figure A Right Angle APL / Pop-off Valve Assembly Figure A Tabletop Flush Valve Assembly Figure A Oxygen Flowmeter Assembly Table Top Only Figure A Tabletop Frame Assembly Figure A Table Top Back Cover Assembly Figure A Tabletop Manifold Block Assembly vi Table of Contents

7 Figure A VDA-4100 Frame Assembly Figure A VDA-4100 Back Panel Assembly Figure A Drawer Assembly Figure Drager Vaporizer Figure Tec3 Vaporizer Figure Millimeter Outlet Caps Figure Ohio Vaporizer Figure Penlon Vaporizer Figure Tec4 Vaporizer Bolt-on Type Figure Tec 4 Vaporizer Latching Type (1 of 2) Figure Tec 4 Vaporizer Latching Type (2 of 2) P/N vii

8 Table of Tables Table 1-1 Facility Requirements Table 6-1 Landmark Anesthesia System: Problem Solution Matrix Table 7-1 Landmark Post-Maintenance Checkout Table 9-1 Pressure Unit Conversions Table 9-2 MAC Levels Table 9-3 Miscellaneous Information Table 10-1 Replaceable Materials and Accessories viii Table of Contents

9 1 Introduction Overview Congratulations on your choice of the Landmark Veterinary Anesthesia System! Your Landmark system is specially designed to be compact, well balanced, and able to withstand the rigors of everyday clinical use providing long-term safe and trouble-free performance. This manual covers the following Landmark models: VSA-2100 VDA-4100 VTA-1100 VWA-3100 RTA-0011 RSA-0021 Single Floor Model Doublewide Floor Model Table Top Wall Mount Table Top Non-Rebreathing System Floor Model Non-Rebreathing System It is recommended that you read the entire manual before attempting to operate your anesthesia system. System Safety Operation of your Landmark Anesthesia System involves oxygen gas pressure and the use of potentially hazardous materials. In order to prevent injury to patients and/or operators and damage to the anesthesia system, please review Section 2 Safety before performing any of the procedures contained in this manual. If you have any safety questions or comments, please contact Vetland or your local distributor. WARNING! This veterinary anesthesia system should only be operated by veterinary professionals qualified to administer anesthesia. General Description The Landmark Veterinary Anesthesia System is a device that allows for the administration of anesthetic and non-anesthetic gases to patients. If equipped with a vaporizer, the machine is also capable of delivering an anesthetic agent in the form of a vapor in conjunction with the gas or gas mixture. The vaporizer converts a liquid anesthetic into a measured amount of vapor, which is then carried to the patient by the oxygen or gas mixture. Figure 1-1shows a diagram of how the system operates. Before anesthesia can be administered, an oxygen (and/or other medical gas) supply is connected to the anesthesia machine, the vaporizer is filled with anesthetic agent, and absorber canister is filled with CO 2 absorbent. The breathing bag, patient breathing circuit, and all accessory tubing and bags are then connected. The operator increases the oxygen flow rate by turning the flow meter control valve counterclockwise until the desired rate is indicated on the meter. The breathing bag gradually inflates. Next, the operator sets the anesthetic agent (e.g., Sevoflurane and/or Isoflurane) concentration (%) by turning the knob on the vaporizer(s) to the desired setting(s). Introduction 1-1

10 The wye connector of the patient breathing circuit is attached to the mask or 15 mm endotracheal tube connector. The gas mixture flows through the inspiratory valve into the patient s lungs. The patient exhales through the expiratory valve into the breathing bag where the exhaled gas mixes with the constantly flowing fresh gas. In a rebreathing type circuit, the fresh and exhaled gas mixture is forced through the CO 2 absorber where the exhaled carbon dioxide is removed and the ventilation cycle is repeated. In a non-rebreathing circuit, the exhaled gases are vented into a waste gas scavenger system. The operator determines the inspiratory pressure for ventilating the patient by adjusting the pop-off valve while observing the system s pressure gauge. The more the pop-off valve is closed, the higher the pressure ISO To Scavenger System psi O Item Description Item Description 1 Anesthetic Vaporizer 7 Patient s Lungs 2 O 2 Flow Meter 8 Expiratory Valve 3 O 2 Flowmeter Control Valve 9 Rebreathing Bag 4 O 2 Flush Valve 10 Pop Off Valve 5 Inspiratory Valve 11 CO 2 Absorber 6 15 mm Endotracheal Tube Connector 12 cmh 2 0 Pressure Gauge Figure 1-1 Landmark System Flow Diagram 1-2 Introduction

11 Facility Requirements Table 1-1 provides the facility requirements necessary to ensure reliable operation and safety of the Landmark Anesthesia System. Characteristic Working Area Oxygen Supply Pneumatic Fitting Environment Table 1-1 Facility Requirements Specification Large enough to accommodate the anesthesia system. See Figure 1-2 to Figure 1-4. Delivery Options: Oxygen supply hose from the facility oxygen outlet Type E cylinder mounted to the anesthesia machine via an optional manifold and yoke assembly Type H cylinder strapped to facility wall or a cylinder cart Regulated Inlet Pressure: psi ( kpa) Flow Rate: 20 liters per minute at 55 psi (379 kpa) Oxygen: Medical Grade Diameter Indexed Safety System (DISS) for Oxygen Storage Temperature: 41 to 122 F (5 to 50 C) Operating Temperature: 59 to 95 F (15 to 35 C) Relative Humidity: 5 to 90% (non-condensing) Altitude: 1609 meters (5278 feet) maximum Note: If you have any questions about facility requirements, please contact Vetland or your authorized distributor. Introduction 1-3

12 System Dimensions Front View Side View Figure 1-2 Dimensions - Landmark VSA-2100 Standard Floor Model 1-4 Introduction

13 Width Figure 1-3 Dimensions - Landmark VDA-4100 Double Wide Floor Model Introduction 1-5

14 Figure 1-4 Dimensions - Landmark VTAA-1100 Table Top System 1-6 Introduction

15 Basic System Features Item Description Item Description 1 System Name Plate 8 Breathing Bag Mount 2 Anesthetic Vaporizer 9 Loop Handle 3 Inspiratory Valve 10 Expiratory Valve 4 Inspiratory Valve Port 11 APL / Pop-Off Valve 5 CO 2 Absorber Canister 12 Fresh Gas Connector 6 Expiratory Valve Port 13 Oxygen Flowmeter 7 O 2 Flush Button 14 Pressure Gauge (cmh 2 O) Figure 1-5 System Features (VSA-2100) Introduction 1-7

16 Item Description Item Description 1 System Name Plate 8 O 2 Flush Button 2 Anesthetic Vaporizers 9 Breathing Bag Mount 3 Working Area/Storage Drawer 10 Expiratory Valve 4 Inspiratory Valve 11 APL / Pop-Off Valve 5 Inspiratory Valve Port 12 Fresh Gas Connector 6 CO 2 Absorber Canister 13 Oxygen Flowmeter 7 Expiratory Valve Port 14 Pressure Gauge (cmh 2 O) Figure 1-6 Doublewide System Features (VDA-4100) 1-8 Introduction

17 Item Description 1 Oxygen Flowmeter 2 O 2 Inlet (DISS) 3 System Name Plate 4 Fresh Gas Connector 5 Anesthetic Vaporizer with Key Fill Option Figure 1-7 RTA-0011 Table Top Non-Rebreathing System Introduction 1-9

18 Item Description Item Description 1 System Name Plate 8 Breathing Bag Mount 2 Mounting Plate 9 O 2 Flush Button 3 Anesthetic Vaporizer 10 Expiratory Valve 4 Inspiratory Valve 11 APL / Pop-Off Valve 5 Inspiratory Valve Port 12 Fresh Gas Connector 6 CO 2 Absorber Canister 13 Oxygen Flowmeter 7 Expiratory Valve Port 14 Pressure Gauge (cmh 2 O) Figure 1-8 VWA-3100 Wall Mount 1-10 Introduction

19 Item Description Item Description 1 Pressure Gauge (cmh 2 O) 7 Expiratory Valve Port 2 Anesthetic Vaporizer 8 APL / Pop-Off Valve 3 Fresh Gas Connector 9 Expiratory Valve 4 Oxygen Flowmeter 10 Inspiratory Valve Port 5 CO 2 Absorber Canister 11 Inspiratory Valve 6 Breathing Bag Mount 12 O 2 Flush Button Figure 1-9 Dimensions - Landmark VTAA-1100 Table Top System Introduction 1-11

20 Description of Landmark Features Feature Anesthetic Vaporizer (Drager Vaporizer Shown) Breathing Bag Mount CO 2 Absorber Canister Expiratory Valve Expiratory Valve Port Fresh Gas Connector Inspiratory Valve Inspiratory Valve Port Loop Handle O 2 Flush Button Description Converts a liquid anesthetic agent into a vapor which is added to the preselected gas (O 2 ) or gas mixture (O 2, nitrous oxide, air). The anesthetic vapor is measured in volume percent (vol %). A dial atop the vaporizer allows the operator to select the amount of vapor administered to the patient. A universal vaporizer mount allows mounting of all major vaporizer brands. Connection for the breathing bag when using the anesthesia system in a circle rebreathing circuit configuration. The 1,030 cc absorber canister is filled with a granular carbon dioxide (CO 2 ) absorbent material (e.g., Litholyme ) that removes CO 2 from the breathing system. The absorber subsystem uses a coaxial gas flow path to provide for more efficient use of absorbent, while reducing flow resistance. The chemical reaction that takes place in the canister creates heat and humidity that aids in the delivery of anesthesia to the patient. Contains a nickel-plated brass, one-way valve that utilizes a flutter disk to control the flow of gases within the patient expiratory breathing circuit. Port to which the expiratory breathing hose circuit is connected. For rebreathing circuit applications, a 15 mm tapered outlet port that routes the fresh gas mixture to the inspiratory port. For non-rebreathing applications, the male 15 mm connector is removed and the 15 mm male connector of the non-rebreathing circuit is connected. Contains a nickel-plated brass, one-way valve that utilizes a flutter disk to control the flow of gases within the patient inspiratory breathing circuit. Port to which the inspiratory breathing hose circuit is connected. Provides a hand-hold for steadying a floor model anesthesia system while it is being rolled to where it is to be used. Pushing this button actuates a valve located prior to the inspiratory port of the anesthesia apparatus which delivers approximately l/min. of oxygen flow to the patient s breathing circuit. This provides for quick oxygenation, while by-passing the anesthetic vaporizer and any other medical gases. Oxygen Flowmeter Controls the flow of oxygen into the anesthesia system. By turning the O 2 flow valve knob and monitoring the location of the ball in the calibrated tube, the operator can precisely adjust the flow of oxygen from 200 ml/min to 4 L/min. Single or dual resolution flowmeters are available. APL / Pop-Off Valve System Name Plate System Pressure Gauge Working Area/Storage Drawer An Adjustable Pressure Limiting (APL) valve that allows the operator to vent the breathing circuit by adjusting the knob at the top of the valve. The valve is vented to the facility scavenging system. Displays the model number and serial number of your Landmark machine which is required when contacting Vetland for machine servicing or warranty issues. The nameplate also contains Vetland s tollfree telephone number. Measures and displays the pressure in the patient breathing circuit. The convenient storage drawer on the VDA-4100 Doublewide model provides storage for medical or maintenance supplies. The deck on top of the drawer provides table space for surgical supplies or instruments Introduction

21 2 Safety Overview This section provides basic safety information necessary for operating your Landmark Anesthesia System. Please contact the Vetland s 24-hour customer service department at or your local dealer for answers to your specific safety questions. Intended Use The Landmark Anesthesia System is intended for veterinary use only and functions as described when operated and maintained in accordance with the procedures of this manual. Misuse of your system may result in injury to patients and operators and/or damage to property. Misuse includes: Using inappropriate gases and anesthetic agents Making unauthorized modifications to the equipment Operating the system using gas pressure exceeding maximum ratings WARNING! Landmark Anesthesia Systems should only be operated by veterinary professionals qualified to administer anesthesia to animal patients. Description of Safety Symbols The following types of symbols are included in this manual with notes that alert the reader to potential hazards. WARNING! Personal Safety Warning - This symbol appears in a shaded text block to warn you about actions that could cause personal injury or death. CAUTION! Property Damage Caution - This symbol appears in a shaded text block to warn you about actions that could cause damage to the system or the facility. Safety 2-1

22 Basic Safety Precautions and Practices This section provides requirements necessary to ensure safe and reliable operation of your Landmark Anesthesia System. Patient and Operator Safety Always keep a backup anesthesia delivery plan in place should an emergency occur. Any person responsible for the installation or operation of the system should be thoroughly familiar with this operator s manual. To ensure proper function of your system, perform a pre-use checkout procedure in accordance with Section 5 Operation. The system must always be attended by a veterinarian or trained anesthesia technician. Vetland recommends service inspections by a Vetland-certified technician at regular intervals to ensure proper operation of the equipment and safety of patient and staff. Only Vetland-certified technicians should be permitted to service the system or replace internal parts. Keep open flames and combustibles (e.g., ether and acetone) away from the anesthesia system. Do not place more than 7 lbs. (3.2 kg) on top of the Mayo tray (if installed). Make sure that the oxygen hose does not cross walkways and aisles. This may present a tripping hazard. Follow the anesthetic agent manufacturer s Material Safety Data Sheet (MSDS) recommendations for personal protective equipment, proper handling, and treatment of injury resulting from exposure. Make sure the oxygen hose is securely connected to the system before starting a procedure. Make sure that any exhaled gas containing anesthetic is vented outside of the operating room. A waste gas evacuation system must be used. Vetland recommends the use of an electro cardiograph, and equipment capable of monitoring the patient s pulse, oxygen (O 2 ) saturation, carbon dioxide (CO 2 ) level, and anesthetic agent level at all times when operating the system. Remove the system from service if any indications of improper function exist. Use only medical grade compressed oxygen which meets USP purity standards. Never pour water or any other fluids into the anesthetic vaporizer. Fill vaporizer only with the anesthetic agent for which it is designed. Avoid use of oil or grease on any anesthesia or respiratory equipment where oxygen is used. An explosion may occur. Never use pressure-reducing regulators with any gases other than those identified on the regulator. When using large G or H type cylinders, or a central medical gas supply system, make sure the supply pressure to the anesthesia system is at least 50 psi, but no more than 60 psi. 2-2 Safety

23 Preventing System and Facility Damage Immediately contain and clean up spilled anesthetic as recommended in the manufacturer s MSDS. Isoflurane is very caustic and may dull the paint finish of the system if spillage occurs. If spillage should occur, allow it to evaporate. Do not attempt to wipe it with a cloth. Vetland recommends using a filler attachment to add anesthetic agents. Do not place more than 7 pounds (3.2 kg) on top of the Mayo tray (if installed). Follow all recommended system maintenance procedures specified in Section 7 Maintenance. Make sure the system is properly secured to the wall of the facility if used as a wall-mounted system. Inappropriate fasteners may pull out and cause the system to fall to the floor. Make sure the gas supply is within the required rating. Facility Environmental Health Immediately contain and clean up any spilled anesthetic agent as recommended in the manufacturer s MSDS. If the system is used in a confined space, ensure that there is adequate ventilation. If volatile organic compound (VOC) emissions exceed safe limits, facility ventilation systems must be in operation. Dispose of any hazardous materials and items contaminated with hazardous materials in accordance with applicable Federal, state, and local statutes and regulations, facility practice, and practices recommended by the MSDS. Halothane Precautions When using the anesthetic agent Halothane, the operator should be aware of any discoloration of the agent. The discoloration may be caused by Thymol, a stabilizer which is only used in Halothane. The change from a clear liquid to a yellowish/brownish color can be noticed in the sight glass. If this occurs, drain all the Halothane from the vaporizer and discard. Fill the Vaporizer with fresh Halothane. If this does not take care of the problem, the vaporizer needs to be serviced. Contact Vetland or your local dealer. System Malfunction If your system does not operate properly, refer to Section 6 Troubleshooting which includes descriptions, possible causes, and suggested solutions. Emergency Shutdown In the event of a major malfunction, shut down the system as follows: 1. Turn off the oxygen supply. 2. Set the vaporizer(s) to zero percent. 3. Disconnect the facility O 2 supply line (if used). 4. Switch the patient to a backup anesthesia delivery system and continue the medical procedure. 5. Contact Vetland or your local dealer for service. Safety 2-3

24 Moving a Stand-mounted Landmark System 1. Turn off the medical gas supply. 2. Securely stow the medical gas supply hose (if used) on the anesthesia system. 3. Grip the handle and back panel of the system firmly as shown in Figure Carefully roll the system to its new location. Use extra caution when moving the machine over uneven areas, thresholds, and other obstacles. Figure 2-1 Moving a Stand-mounted Landmark Machine 2-4 Safety

25 3 Unpacking and Assembly Overview This section provides the unpacking and assembly procedure for your Landmark Anesthesia System. Unpacking the System Your system is shipped in boxes that have been carefully packed at the factory for safe delivery of the system to you. When you receive your system, please do the following: 1. Check the shipping documents to ensure that all boxes have been received. 2. Examine the shipping boxes for damage. Immediately make a damage claim to the carrier if there is serious damage. 3. Carefully open each box and remove each individual component. Save all boxes and packing materials for future shipments. CAUTION! Open shipping boxes carefully to avoid damaging the contents. 4. Check the invoice to make sure all ordered components are included. If not, please contact Vetland or your local distributor. Maintenance 3-1

26 Assembling the System Stand Mount Assemble a stand-mounted Landmark Anesthesia System in the sequence shown in Figure 3-1. Note: The mayo tray is optional on the Doublewide Model (VDA-4100). WARNING! Some components of the system are heavy. Use caution while lifting these components to avoid injury (x 5) Figure 3-1 Assembling a Stand Mount System 3-2 Unpacking and Assembly

27 Assembling the System Wall Mount Assemble a wall-mounted Landmark Model VWA-3100 in the sequence shown in Figure 3-2. WARNING! Some components of the system are heavy. Use caution while lifting these components to avoid injury. CAUTION! Attach the wall bracket to studs whenever possible. The bracket holes are on 16- inch centers. Use wall fasteners appropriate for supporting the weight of the fully equipped system. 1 2 (x 2) (x 4) 3 (x 2) 4 Figure 3-2 Assembling the Landmark Wall Mount Maintenance 3-3

28 4 System Setup Overview This section provides the setup procedures required to prepare your Landmark Anesthesia System for veterinary surgical procedures. Materials and Supplies Oxygen supply source [50 (+10, -0) psi, 345 (+69, -0) kpa] Patient breathing circuit: Rebreathing (Universal F-Circuit) 22 mm corrugated hoses and 15 mm wye connector, mask, or endotracheal tube with 15 mm endotracheal tube connector Non-rebreathing (Modified Jackson Rees) Breathing bag CO 2 absorbent (e.g., Litholyme ) Anesthetic agent (e.g., Sevoflurane, Isoflurane) 19 mm hose and scavenger interface, with a passive or active waste gas elimination system Wrench for tightening oxygen supply fitting Initial System Preparation Setting Up the System 1. Position the system in the area where it will be used. 2. Connect the oxygen supply hose to the DISS fitting on the oxygen inlet port (see Figure 4-1). 3. Open the APL/pop-off valve by turning the knob counterclockwise. 4. Turn the volume percent (vol. %) dial on the anesthetic vaporizer to the zero (0) position. 5. Ensure the oxygen supply valve is turned off. 6. Fill the CO 2 absorber canister with absorbent as follows: a. Turn the canister fastener knob counterclockwise and remove the absorber canister (see Figure 4-1). b. Fill the absorber canister with CO 2 absorbent to within 1 inch of the top of the canister. Take care that the granules do not interfere with the sealing surfaces. c. Reinstall the absorber canister and turn the knob clockwise until hand-tight. CAUTION! Do not over-tighten the canister knob. Excessive tightening may damage the absorber canister. System Setup 4-1

29 0 USE ONLY ISOFLURANE VETERINARY USE ONLY 1 + Figure 4-1 Installing O 2 Hose and Absorber Canister 4-2 System Setup

30 Filling the Anesthetic Vaporizers Funnel Fill 1. Clean any hair or debris from around the filler port with a clean cloth. 2. Place a clean cloth beneath the anesthetic filler port. 3. Turn the filler valve knob two turns counterclockwise to open. 4. Carefully pour the appropriate agent into the filler port using a filler tube or funnel. WARNING! Make sure to pour the correct anesthetic into the filler port. Filling with the incorrect anesthetic agent could cause serious injury or death to the patient. CAUTION! If anesthetic agent spills on system surfaces, allow it to evaporate. Rubbing spilled anesthetic agent with a cloth may damage the system finish. 5. Observe the agent level sight glass on the vaporizer (see Figure 4-2). Stop filling the vaporizer when the agent level inside the tube reaches the top line of the sight glass. Note: On a new, dry vaporizer, monitor the level for several minutes and refill the reservoir as necessary until the internal wick is saturated and the level stabilizes at the top line of the sight glass. 6. Turn the filler valve knob clockwise to close Item Description Item Description 1 Filler Valve 4 Filler Port 2 Agent Level Sight Glass 5 Drain Port Knob 3 Agent Filler Tube/Funnel Figure 4-2 Filling the Vaporizer (Drager) Funnel Fill System Setup 4-3

31 Filling the Anesthetic Vaporizers Key Fill Note: The optional key fill feature ensures that only the correct anesthetic agent is allowed to fill its corresponding vaporizer. 1. Clean any hair or debris from around the filler port with a clean cloth. 2. Place a clean cloth beneath the anesthetic filler port. 3. Remove plug from the keyed filler port see Figure Insert the keyed filler connector from the appropriate anesthetic container into the filler port. 5. Turn the filler valve knob counterclockwise to allow the anesthetic agent to flow into the vaporizer. CAUTION! If anesthetic agent spills on system surfaces, allow it to evaporate. Rubbing spilled anesthetic agent with a cloth may damage the system finish. 6. Observe the agent level sight glass on the vaporizer (see Figure 4-3). Close the filler valve clockwise when the agent level inside the tube reaches the top line on the sight glass. 7. Remove the filler connector and insert the plug into the keyed filler port Item Description Item Description 1 Fill Port Valve 5 Drain Port Valve 2 Agent Level Sight Glass 6 Keyed Fill Port 3 Keyed Agent Filler Tube 7 Fill Key Lock 4 Fill Port Plug 8 Drain Key Lock Figure 4-3 Filling the Vaporizer (Drager) Key Fill 4-4 System Setup

32 Connecting the Breathing Circuit Rebreathing Circuit Installation Note: The rebreathing circuit is designed to be used with animals larger than pounds. For more information, consult a veterinary anesthesiologist at a local veterinary school/university and/or refer to the Handbook of Veterinary Anesthesia (William W. Muir III, DVM PhD and John A. E. Hubbell, DVM MS DACVA; Publisher: Mosby Elsevier). Attach the rebreathing circuit to the anesthesia system as shown in Figure 4-4. Connect to Inspiratory Port Connect to Expiratory Port Connect to Breathing Bag Mount Connect to Endotracheal Tube or Mask Figure 4-4 Rebreathing Circuit (Universal F-Circuit) Connections System Setup 4-5

33 Non-rebreathing Circuit Installation Note: The non-rebreathing circuit (modified Jackson-Rees) is for patients less than pounds. For more information, consult a veterinary anesthesiologist at a local veterinary school/university and/or refer to the Handbook of Veterinary Anesthesia (William W. Muir III, DVM PhD and John A. E. Hubbell, DVM MS DACVA; Publisher: Mosby Elsevier). Attach the non-rebreathing circuit to the anesthesia system as shown in Figure 4-5. Connect to Endotracheal Tube or Mask Connect to Scavenger System Connect to Fresh Gas Outlet (15 mm Adapter) Note: Waste gas tubing is required to be 19 mm in diameter; however, some charcoal filter waste gas systems are sized at 22 mm. In this case, a 22 mm to 19 mm adapter (P/N 81915B) is required. Figure 4-5 Non-Rebreathing Circuit (Modified Jackson Rees) Connections 4-6 System Setup

34 5 Operation Overview This section provides the procedures and information needed to successfully operate your Landmark Anesthesia System. WARNING! CAUTION! Only trained veterinary professionals should operate the Landmark Anesthesia System. Pre-use Checkout Perform the pre-use checkout procedure before each use of your Landmark system as follows: 1. Fill the vaporizer as specified in Section 4 System Set-up. 2. Make sure the vaporizer volume-percent (vol. %) dial is set to zero (0). 3. Confirm that the CO 2 absorbent canister is filled within one inch of the top and that absorbent has not expired (turned purple). Refill the canister with fresh absorbent if necessary. CAUTION! Some activated dyes can revert to a neutral color after a few days. Therefore, make sure the granules are not desiccated and are still absorbing CO 2. Quality of the absorbent in the canister can be determined by monitoring the CO 2 levels inspired by the patient. High CO 2 levels indicate the absorbent has expired. Vetland recommends Lytholyme absorbent which has a dye that retains its color. 4. Ensure the anesthesia system is connected to a 50 psi oxygen source. 5. Confirm the oxygen supply as follows: a. Ensure that the oxygen source has sufficient reserve to supply oxygen for the duration of the case. b. Ensure that no other O 2 delivery device is using the same cylinder and then note the pressure level in the cylinder. c. Turn the oxygen cylinder valve ON and then OFF again. The cylinder pressure gauge should not drop more than 50 psi in 2 minutes. If pressure drops, there is a leak. Immediately call for maintenance. Operation 5-1

35 6. Verify oxygen flowmeter function as follows: a. Turn ON the oxygen supply. Figure 5-1 Valve Test Setup b. Turn the flowmeter knob fully counterclockwise and then fully clockwise while viewing the movement of the flow ball. The flow ball should move freely throughout the length of the tube. The flowmeter knob should move easily. 7. Confirm proper function of the inspiratory and expiratory valves as follows: a. Connect a breathing bag to the end of an F-circuit (Figure 5-1) to simulate a lung. b. Turn the flowmeter knob counterclockwise to provide O 2 to the system and inflate the breathing bag. c. Squeeze the breathing bag and observe the inspiratory and expiratory valves. Each valve should move freely and seal when pressure to the valve is applied. 8. Perform a pressure leak test as specified in Section 6 Troubleshooting. 9. If using a rebreathing circuit, check the waste gas scavenging system as follows: a. Connect one end of the scavenging system hose to the pop-off valve. Note: Do not connect the scavenging hose from a non-rebreathing circuit to the pop-off valve. b. Connect the other end of the scavenger system hose to an active scavenging system (e.g., vacuum pump) or passive scavenging system (e.g., charcoal filter). c. Verify that exhaust gases from the anesthesia system are traveling unrestricted via the scavenger tubing to the outdoors if using an active system or to the charcoal canister if using a passive system. 5-2 Operation

36 d. Verify that there is neither a positive or negative pressure being applied to the patient s breathing via the scavenging system. If so, refer to Table 6-1, Items 5 and 6 for solution. 10. Install a clean rebreathing circuit (reference Figure 4-5) and breathing bag on the anesthesia system. 11. Check ventilator function (if used) as follows: a. Verify the connection of the breathing circuit. b. Check the ventilator for performance according to manufacturer s specifications. Inspiratory Pressure Adjustment The operator can determine the inspiratory pressure for positive pressure ventilation of the patient by adjusting the pop-off valve while observing the cmh 2 O pressure gauge. The more the pop-off valve is opened, the lower the inspiratory pressure; the more the valve is closed, the higher the inspiratory pressure. Note: The pop-off valve must never be closed completely during manual or spontaneous ventilation while using a closed patient breathing circuit. A complete closure of the valve causes an excessive build-up of pressure, which may be harmful to the patient. During the ventilation process, the operator should monitor the pressure gauge at all times. Again, close attention must be paid to the cmh 2 0 pressure gauge to avoid excessively high, negative, or continuing pressures. When fully opened (counterclockwise) the pop-off valve keeps a small 1 to 2 cmh 2 O pressure in the system. This maintains a fully distended breathing bag and allows the equipment operator to bag without having to adjust the pop-off. This small pressure does not create any danger to the patient. The pop-off valve has a 19 mm scavenger port, which must be connected to 19 mm tubing. When using a rebreathing circuit, this tubing is routed to a waste gas disposal system (such as an active scavenging system, charcoal canister, or routed passively out of the room). During many veterinary anesthesia procedures, the patient will breathe spontaneously. In those cases, it will be much easier to determine the correct fresh gas flow and pop-off valve setting. The oxygen flow control setting and the pop-off valve should be set so that the breathing bag neither collapses during inspiration nor over-inflates during exhalation. The inspiratory/expiratory pressures should be in the low range of the cmh 2 O pressure gauge. It is often believed that when a closed patient breathing circuit is used, a patient has to exhale against a high resistance. This is not the case under normal conditions. The patient exhales via the expiratory valve into the breathing bag and bypasses the CO 2 absorber. The resistance of the expiratory valve should be 1 cmh 2 O or less. Neither is it correct that a patient will rebreathe a large amount of exhaled gas due to the distance between the wye connector and the expiratory valve. The patient will only rebreathe the volume of gas between the wye connector of the breathing circuit and its mouth, nose, or endotracheal tube. Rebreathing Circuit vs. Non-rebreathing Circuit Except for RTA/RSA series non-rebreathing systems, Landmark Anesthesia Systems have a semi-closed circle breathing system (rebreathing circuit) or a connector for non-rebreathing applications. In a rebreathing patient breathing circuit, a portion of the exhaled breath is recycled. In a non-rebreathing system, all exhaled gases, including the anesthetic agent, are lost to a scavenging system and not recycled. The non-rebreathing circuit can be connected directly to the 15 mm fresh gas outlet located on the back panel to the right of the vaporizer. When using a non-rebreathing circuit, the fresh gas flow must be adjusted high enough to prevent the rebreathing of exhaled CO 2. It is strongly recommended that a CO 2 monitor be used to monitor proper ventilation. Operation 5-3

37 The reason for using a non-rebreathing circuit instead of a rebreathing patient breathing circuit is not only to decrease the resistance during respiration, but also to control the inspired gases. Therefore, it may be desirable to use a non-rebreathing circuit for patients that weigh 10 pounds or less. For more information, consult a veterinary anesthesiologist at a local veterinary school/university and/or refer to the Handbook of Veterinary Anesthesia (William W. Muir III, DVM PhD and John A. E. Hubbell, DVM MS DACVA; Publisher: Mosby Elsevier). Using the Oxygen Flush Button If the patient should require high concentrations of oxygen instantaneously, the operator can activate the oxygen flush button. Once activated, the flow meter and anesthetic vaporizer are bypassed and oxygen is administered to the patient without anesthetics. As soon as the oxygen flush button is released, the preset anesthesia mixture will again be administered. Note: The oxygen flush is always available to the patient as long as there is 50 psi of oxygen supply pressure. Should the system become unable to provide fresh gas mixtures, the O 2 flush can be utilized to oxygenate the patient. Use caution to avoid over pressurizing the anesthesia system/patient. Anesthetic Vaporizer The vaporizer is the most complex and the most expensive component of the anesthesia system. It requires special care and the understanding of some basic facts. The vaporizer converts a liquid anesthetic agent into a vapor which is added to the pre-selected gas (oxygen) or gas mixture (oxygen, nitrous oxide, air). The output of the vaporizer, which is the anesthetic vapor, is measured in volume-percent (vol. %). A dial allows the operator to select the amount of anesthetic vapor administered to the patient. There are several factors which influence the output of any vaporizer: Change of ambient temperature Change of flow rates Pressure fluctuations Change of delivery gas (e.g. change from oxygen to oxygen/nitrous oxide mixture) Most vaporizers compensate for those changes as they occur. However, the greater the change, the longer it may take for the vaporizer to compensate. The operator must be aware of these vaporizer characteristics, particularly, when decreasing the volume percent concentration of the vaporizer. Also, volume percent concentrations of the anesthetic agent may vary from the selected setting, when flow rates of the delivery gas or gases are below 1.0 l/min. or above 10.0 l/min. Vaporizers are calibrated for a specific anesthetic agent. Never use an agent other than the one for which the vaporizer is specified. The use of the wrong agent may be detrimental to the patient. 5-4 Operation

38 Post-anesthesia Procedure Once the anesthesia procedure is completed, perform the following steps in order: 1. Turn OFF the vaporizer by turning the volume-percent (vol. %) dial clockwise to zero (0). The dial clicks into place. 2. If applicable, turn off the nitrous oxide supply. 3. Close the flowmeter valve by turning the knob clockwise until the oxygen flow reads zero (0) l/min. CAUTION! Do not over-tighten the oxygen control knob or the needle valve will be damaged. 4. Press the oxygen flush button for two to three seconds and squeeze the breathing bag to purge the system of anesthetic gases and carbon dioxide. 5. Close the oxygen cylinder valve or disconnect the oxygen supply hose from the facility supply system to prevent unintended pressure build-up. 6. Open the pop-off valve by turning it counterclockwise. This assures that, while breathing spontaneously, the next patient can exhale freely and with no resistance. 7. Check the absorbent in the CO 2 absorber canister. If the color has turned blue or after approximately 8 to 10 hours of surgery, change the absorbent as described in Section 4 System Setup. The blue dyes in the absorbent are activated when CO 2 can no longer be absorbed. Note: Expired absorbent can change back to white overnight, unless you are using Litholyme TM absorbent available from Vetland which retains its color change indefinitely. TIP To make sure the CO 2 absorbent is fresh, change the absorbent each time anesthetic agent is added. 8. Thoroughly clean the anesthesia system with germicidal cleaning solution as described in Section 7 Maintenance. Operation 5-5

39 6 Troubleshooting Overview This section will help you determine the origin of common problems you may experience with your Landmark Anesthesia System and recommended corrective actions. If you experience problems not listed in this section, or continue experiencing the problem after trying the suggested corrective actions, please contact Vetland or your local dealer for advanced fault diagnostics. WARNING! CAUTION! Only trained Vetland service technicians should perform troubleshooting not included in this section. Safety Some troubleshooting procedures may involve the use of hazardous materials and contact with biological hazards. Always follow all applicable Federal, state, and local regulations and the material manufacturer s Material Safety Data Sheet (MSDS) recommendations including: Personal protective equipment (i.e., gloves, mask, eye protection) Disposal of contaminated items (i.e., disposable breathing circuit components, cleaning cloths) Disposal of hazardous materials (such as cleaning solutions and anesthetic agents) Treatment of chemical injury to personnel Material flammability Machine Status Unless otherwise specified, the anesthesia system may be connected to gas supplies during the performance of the troubleshooting procedures described in this manual. Record Keeping A record of problems and their resolution should be kept. Such records should include the date, the nature of the problem encountered, and the actions that resolved the problem. Troubleshooting 6-1

40 Problem Solution Matrix Table 6-1 contains problems that may occur during operation of your Landmark Anesthesia System and their corrective actions. If you continue experiencing a problem after trying the suggested corrective actions, please contact Vetland or your local dealer for advanced fault diagnostics. Table 6-1 Landmark Anesthesia System: Problem Solution Matrix No. Problem Cause Solution 1 No or low anesthetic vapor output 2 APL/Pop-off valve knob is hard to turn 3 Needle on system pressure gauge is stuck and does not move 4 Needle on system pressure gauge does not read zero (0) or is fluctuating when all gases are turned off 5 Needle on system pressure gauge indicates several centimeters of positive pressure after exhalation has ended 6 Needle on system pressure gauge indicates a negative pressure a. Vaporizer is functioning properly, but machine output is not getting to patient b. Anesthetic agent reservoir is empty c. Vaporizer is turned off d. Leak around the vaporizer filler port e. Vaporizer malfunction internal fault Pop-off valve threads require cleaning Mechanical damage Gauge requires adjustment Constriction or obstruction downstream from the APL/pop-off valve a. Excessive scavenger system vacuum b. Inadequate fresh gas flow Check breathing system components for leaks, tears, holes, etc. Ensure the cone/mask makes a good seal with the patient. Perform a System Pressure Leak Test as specified below. Fill the reservoir with appropriate anesthetic drug. Press the white 0 button on the vaporizer and adjust the dial to the desired volume-percent of anesthetic. Make sure the fill and drain valves on the vaporizer are fully closed. Contact Vetland or your local dealer for servicing. Contact Vetland or your local dealer for servicing. Replace cmh 2 O pressure gauge. Contact Vetland or your local dealer for instructions. Carefully remove lens cover from cmh 2 O pressure gauge with knife blade or screw driver and adjust set screw with jeweler s screwdriver to 0 position. Disconnect the pop-off valve exhaust hose and monitor the pressure gauge. If the pressure does not return to zero, contact Vetland or your local dealer. If pressure returns to zero: a. Check the exhaust hose for possible obstruction due to moisture buildup or debris. b. Remove the obstruction. c. Reconnect the hose to the pop-off valve. Decrease scavenger system vacuum. Recommend a scavenger interface valve to prevent removal of patient gases. Also see items 9c and 10c. Increase fresh gas flow rates. 6-2 Troubleshooting

41 Table 6-1 Landmark Anesthesia System Problem Solution Matrix (continued) No. Problem Cause Solution 7 Patient sleep level seems too light a. Vaporizer is empty Fill vaporizer with the appropriate anesthetic. 8 Patient sleep level seems too deep 9 Breathing bag is overly distended 10 Gas is flowing, but breathing bag does not inflate 11 Gas flow is leaving through expiratory port when squeezing breathing bag. b. Anesthetic concentration is set too low c. Leak in patient breathing circuit d. Excessive CO 2 build-up e. Leak around the vaporizer filler port f. O 2 Flush Valve is Leaking/Faulty a. Anesthetic concentration is set too high b. Vaporizer malfunction a. APL/Pop-off valve is closed b. Flow rate is set too high c. Scavenger system suction is set too low or is occluded a. Breathing bag is punctured b. APL/Pop-off valve is completely open c. Scavenger system suction is set too high Malfunctioning expiratory valve Press the white 0 button on the vaporizer and adjust the dial to the desired volume-percent of anesthetic. Perform a System Pressure Leak Test as specified below. 1. Check CO 2 absorbent and replace if necessary. 2. Check proper function of inspiratory and expiratory valves. 1. Make sure the fill and drain valves on the vaporizer are fully closed. 2. Verify that the fill and drain valve o-rings are not damaged. Replace if damaged. 3. Verify that filler and drain ports are not obstructed by animal hair, etc. Replace the flush valve. Contact Vetland or your local dealer for instructions. Reduce concentration of anesthetic (vol. %). Contact Vetland or your local dealer for servicing. Open the pop-off valve. Turn the flowmeter valve knob clockwise to decrease the oxygen flow rate. Increase vacuum flow for scavenger suction or install a scavenger interface valve vented to atmosphere. Replace breathing bag and mount the new bag securely on the bag mount Turn the knob on the pop-off valve clockwise until the bag starts to inflate. Decrease scavenger system suction. or Install a scavenger interface valve vented to atmosphere. Unscrew knurled ring from expiratory valve and check disk. Disk must be sitting flush on top of seat and move freely within the bumper check retainer. Troubleshooting 6-3

42 Table 6-1 Landmark Anesthesia System Problem Solution Matrix (continued) No. Problem Cause Solution 12 No gas flow a. Facility or cylinder gas supply valve is closed b. Gas cylinder is empty c. Gas supply hose is disconnected 13 Gas flow is not sufficient 14 Oxygen flush button sticks 15 Float in oxygen flowmeter sticks d. Oxygen flow control turned off e. Gas supply regulator malfunction a. Oxygen flow is set too low b. Leak around vaporizer filler ports. c. Leak in patient breathing circuit d. CO 2 absorber canister is leaking Malfunctioning flush valve Dirty flow tube Open gas supply valve. Replace empty gas cylinder. 1. Ensure gas supply hose is connected to the cylinder or facility gas system. 2. Ensure the gas supply hose DISS connector is securely connected to the anesthesia system. Turn the flowmeter valve knob counterclockwise to increase the oxygen flow rate. Connect the system to an alternate oxygen supply. Turn the flowmeter valve knob counterclockwise to increase the oxygen flow rate. 1. Make sure the fill and drain valves on the vaporizer are fully closed. 2. Verify that the fill and drain valve o-rings are not damaged. Replace if damaged. 3. Verify that filler and drain ports are not obstructed by animal hair, etc. 1. Check all hose connections, particularly around mask or endotracheal tube. 2. Perform a System Pressure Leak Test as specified below. 1. Shut down the anesthesia system. 2. Remove the absorber canister 3. Remove any absorbent granules that are lodged between the canister and sealing gasket. 4. Reinstall the absorber canister. The flush valve requires cleaning or replacement. Contact Vetland or local dealer for service. Flow tube needs cleaning. Contact Vetland or local dealer for service. 16 Oxygen flow control valve knob is hard to turn 17 Audible leakage around oxygen hose connector Dirty or damaged needle valve a. Loose oxygen hose connection b. Damaged oxygen DISS inlet fitting Flow valve needs cleaning or replacement. Contact Vetland or local dealer for service. Tighten the connection with a crescent wrench. Inlet must be replaced. Contact Vetland or your local dealer for service. 6-4 Troubleshooting

43 System Pressure Leak Test F-circuit Method 1. Set up the anesthesia system as shown in Figure 6-1. APL/Pop-off Valve Universal F-Circuit Breathing Bag Figure 6-1 Pressure Test Setup 2. Open the O 2 supply valve and provide 50 psi O 2 to the anesthesia system. 3. Attach a rebreathing circuit to the system. 4. Attach a breathing bag to the bag mount located below the APL/pop-off valve. 5. Close the APL/pop-off valve. 6. Plug the wye piece or elbow connector of the F-circuit using your thumb. 7. Continue to plug the end of the breathing wye or elbow while pressurizing the absorber system to 30 cmh 2 O using the O 2 flush valve. The system pressure should not drop more than 5 increments (30 cmh 2 O to 25 cmh 2 O) in 30 seconds. If a leak is present, use a soapy water solution to help find its exact location. Repair or replace the leaking component. 8. Open the APL/pop-off valve and relieve system pressure down to 10 cmh 2 O. 9. On the system flowmeter, set a flow of 250 ml/min. 10. Verify that the pressure reading on the system pressure gauge slowly starts to climb past 20 cmh 2 O. 11. With zero (0) inflow of oxygen, the pressure gauge should read zero. If the gauge pressure climbs, the oxygen flush valve is leaking. 12. Open the APL/pop-off valve to relieve pressure to zero (0). Troubleshooting 6-5

44 System Pressure Leak Test Squeeze Bulb Method 1. Set up the anesthesia system as shown in Figure 6-2. APL/Pop-off Valve Short Circuit Tube Pressure Test Squeeze Bulb Figure 6-2 Pressure Test Setup 2. Open the O 2 supply valve and provide 50 psi O 2 to the anesthesia system. 3. Close the APL/pop-off valve. 4. Using the squeeze bulb, pressurize the absorber system to 30 cmh 2 O. The system pressure should not drop more than 5 increments (30 cmh 2 O to 25 cmh 2 O) in 30 seconds. If a leak is present, use a soapy water solution to help find its exact location. Repair or replace the leaking component. 5. Open the APL/pop-off valve and relieve system pressure down to 10 cmh 2 O. 6. On the system flowmeter, set a flow of 250 ml/min. 7. Verify that the pressure reading on the system pressure gauge slowly starts to climb past 20 cmh 2 O. 8. With zero (0) inflow of oxygen, the pressure gauge should read zero. If the gauge pressure climbs, the oxygen flush valve is leaking. 9. Open the APL/pop-off valve to relieve pressure to zero (0). 6-6 Troubleshooting

45 7 Maintenance Overview This section provides the maintenance procedures to keep your Landmark Anesthesia System in good operating condition. WARNING! CAUTION! Only trained Vetland service technicians should perform maintenance or servicing not included in this section. Safety Some maintenance procedures may involve the use of hazardous materials and contact with biological hazards. Always follow all applicable Federal, state, and local regulations and the material manufacturer s Material Safety Data Sheet (MSDS) recommendations including: Personal protective equipment (i.e., gloves, mask, eye protection) Disposal of contaminated items (i.e., disposable breathing circuit components, cleaning cloths) Disposal of hazardous materials (such as cleaning solutions and anesthetic agents) Treatment of chemical injury to personnel Material flammability Annual Inspection Vetland recommends that your Landmark Anesthesia System be inspected annually for proper function by a Vetland certified technician. The inspection should be performed at the very minimum on a regular schedule which assures proper operation of the equipment and safety for patient and staff. Machine Status Unless otherwise specified, the anesthesia system may be connected to gas supplies during the performance of the maintenance procedures described in this manual. However, make sure the oxygen supply is OFF and the vaporizer(s) is set to zero volume-percent (vol. %). Record Keeping A record of system service and maintenance should be kept. Such records should include service and maintenance dates, part numbers of any replaced parts, dates when consumables are replenished, and other pertinent data. Parts and Materials Refer to Section 10 Replacement Parts and Accessories for materials and parts replacement information. Maintenance 7-1

46 Cleaning the Equipment WARNING! Maintenance of the anesthesia system involves possible contact with biological and chemical hazards. Wear gloves, mask, and eye protection during all cleaning procedures. Required Materials and Supplies Tuberculocidal, germicidal cleaning solution. Vetland recommends Metrex Cavicide (P/N ) CO 2 absorbent material. Vetland recommends Litholyme TM (P/N or ) Clean container for washing and rinsing valves Clean cloths for wiping down surfaces and drying components Personal Protective Equipment (masks, eye protection, gloves, etc.) Disposition of Breathing Circuit Components After each use of the anesthesia system, disposition the breathing circuit components as follows: WARNING! To prevent the spread of infection, do not attempt to re-use disposables, masks, hoses, and bacteria filters labeled for single use. 1. Disconnect the used patient breathing circuit and clean or discard in accordance with the manufacturer s recommendations. 2. Disconnect the breathing bag from the bag mount and discard in accordance with Federal, state, and local regulations. 3. Follow the manufacturer s recommended disinfection or sterilization process for reusable hoses, masks, endotracheal tubes, etc. 7-2 Maintenance

47 Weekly Maintenance 1. Wipe all surfaces of the system with a cloth dampened with germicidal cleaning solution. 2. Remove hair, dust, and debris from all vaporizer surfaces; especially around the volume-percent (vol. %) dial and the anesthetic fill port. 3. Check the CO 2 absorbent canister for exhausted absorbent. If more than ¾ of the absorbent has changed color, replace it as follows: a. Remove the canister from the bottom of the machine. b. Shake out the spent absorbent. CAUTION! Do not bang the edge of the canister on any surface. This may damage the sealing surfaces. c. Wash the canister in warm water, and dry thoroughly. d. Wipe the canister gasket, located on the underside of the machine, with a clean cloth dampened with germicidal cleaner. Make sure there is no absorbent residue remaining on the gasket surface. e. Fill the canister with fresh CO 2 absorbent material to within one inch (2.5 cm) of the top edge. f. Reinstall the canister, turn the fastening knob clockwise until snug, and then turn the knob one-quarter turn more. 4. Perform a pre-use checkout as specified in Section 5 Operation. 5. Check the cleanliness of the oxygen supply and scavenging hoses. Clean or replace as necessary. 6. With a cloth dampened with a germicidal cleaner, all surfaces of the anesthesia system. On floor model Landmark systems, also wipe down the chassis and wheels to remove hair and lint that might interfere with moving the system. Maintenance 7-3

48 Monthly Cleaning of Inspiration and Expiration Valves 1. Make sure the oxygen supply to the system is OFF and the vaporizer volume-percent (vol. %) dial is in the zero (0) position. CAUTION! Do not autoclave or use abrasive substances on inspiration/expiration valve components. They will be damaged and may not function properly. 2. Remove the valve rings (see Figure 7-1) by turning them counter-clockwise. 3. Remove the valve caps, o-rings, and valve discs. 4. Immerse all of the removed parts in a germicidal cleaning solution and wipe with a clean cloth to remove all dirt, hair, etc. WARNING! Refer to the cleaning agent manufacturer s MSDS for information concerning safe use, personal protective equipment, and disposal. 5. Rinse the parts in clean water and dry the parts with a clean cloth. 6. Wipe the check valve seat inside and out with a clean cloth moistened with cleaning solution. 7. Reassemble the valves in the order shown in Figure Tighten the valve rings by turning them clockwise until hand-tight. 9. Perform a pre-use checkout as specified in Section 5 Operation Item Description 1 Valve Ring 2 Valve Cover 3 O-ring 4 Valve Disk 5 Check Valve Seat 5 Figure 7-1 Inspiration/Expiration Valve Assembly (Exploded View) 7-4 Maintenance

49 Draining the Vaporizer Follow the steps below to drain standard Draeger vaporizers. For other vaporizers, follow the vaporizer manufacturer s instructions. WARNING! Perform this procedure in a well-ventilated location. Refer to the anesthetic agent manufacturer s MSDS for required personal protective equipment and handling and disposal of waste anesthetic agent. Drain only one reservoir at a time. Do not drain different anesthetic agents into the same container. CAUTION! Do not wipe spilled anesthetic agent from any painted surfaces or the finish may be damaged. Allow the anesthetic to evaporate. Funnel Fill Vaporizer 1. Close the oxygen supply valve to the anesthesia system. 2. Make sure the anesthesia system is in a well-ventilated area. 3. Attach a drain tube to the drain port (see Figure 7-2). Place the other end of the tube in a receptacle to catch the drained anesthetic agent. 4. Open the fill and drain valves by turning the knobs counterclockwise. 5. When the anesthetic agent stops draining from the vaporizer, close the drain valve and then the fill valve by turning the knobs clockwise. 6. Dispose of the anesthetic agent in accordance with the manufacturer s MSDS and local regulations. Item Description 1 Fill Valve 2 Drain Valve 3 Drain Port Figure 7-2 Draining the Vaporizer (Funnel Fill) Maintenance 7-5

50 Key Fill Vaporizer 1. Close the oxygen supply valve to the anesthesia system. 2. Make sure the anesthesia system is in a well-ventilated area. 3. Insert a keyed drain tube to the drain port (see Figure 7-1) and lock it in place by turning the drain port lock knob clockwise. Place the other end of the tube in a receptacle to catch the drained anesthetic agent. 4. Loosen the fill port lock knob counterclockwise and remove the plug. 5. Open the fill valve by turning the knob counterclockwise. 6. Open the drain valve by turning the knob counterclockwise. 7. When the anesthetic agent stops draining from the vaporizer, close the drain valve and then the fill valve by turning the knobs clockwise. 8. Reinstall the fill port plug and tighten the fill port lock knob clockwise. 9. Dispose of the anesthetic agent in accordance with the manufacturer s MSDS and local regulations Item Description 1 Fill Valve 2 Fill Port 3 Fill Port Plug 4 Drain Valve 5 Drain Port 6 Drain Port Lock Knob 7 Fill Port Lock Knob Figure 7-3 Draining the Vaporizer (Key Fill) 7-6 Maintenance

51 Preparing a Vaporizer for Transport There are no serviceable parts in the vaporizer. Should the vaporizer require service at the factory, follow these steps before packaging the vaporizer for transport: Note: If returning a vaporizer for warranty purposes, a Returned Goods Authorization (RGA) number must be obtained. See Section 8 Product Information for details. 1. In a well-ventilated area, drain the vaporizer as specified in Draining the Vaporizer above. 2. Turn the volume-percent dial to the maximum setting and set the oxygen flow to /min. for 20 minutes. 3. After 20 minutes, turn off the oxygen flow, set the volume-percent dial to zero (0) and close the fill and drain valves. 4. Unplug the 15mm elbow from the vaporizer mounting block. 5. Remove the two bolts (on top) and two screws (on bottom) attaching the back cover to the anesthesia system. 6. While supporting the vaporizer, remove the two bolts and washers on the back panel of the anesthesia system that attach the vaporizer manifold (see Figure 7-4). 7. Lower the vaporizer and allow it to rest on the anesthesia system deck (see Figure 7-5). 8. Using a hex wrench, remove the two hex screws attaching the vaporizer to the vaporizer manifold. Retain the hex screws for reinstallation. 9. Carefully package the vaporizer with appropriate padding and return it to Vetland. 10. Reinstall the vaporizer mounting block to the back panel of the anesthesia system. Vaporizer Manifold Bolts Figure 7-4 Landmark Standard - Back Cover Removed Maintenance 7-7

52 1 2 Item Description 1 Vaporizer Manifold 2 Hex Screws (2) Figure 7-5 Removing the Vaporizer 7-8 Maintenance

53 Post-Maintenance Checkout After performing maintenance on your Landmark system, perform a post-maintenance checkout as described in Table 7-1. Table 7-1 Landmark Post-Maintenance Checkout Verify Test Method/ Acceptance Criteria No pressure leaks Perform a System Pressure Leak Test in accordance with Section 6 Troubleshooting. Proper O 2 flush button operation Proper operation of Inspiration and Expiration Valves Proper operation of the APL/Pop-Off Valve Verify that the button does not stick. Visually verify that the valves move freely and do not stick. Verify that the valve easily opens and closes and does not stick. Preparing the System for Storage 1. Turn off the oxygen supply valve and disconnect the facility oxygen supply line (if used). Remove and safely store E-size stand-mounted oxygen cylinders (if used). 2. Remove and discard disposable breathing tubes and bags in accordance with local regulations. 3. Empty and clean the CO 2 absorber canister. Discard the absorbent material in accordance with the manufacturer s MSDS and local regulations. 4. Drain the vaporizer(s) as specified in Draining the Vaporizer earlier in this section. 5. Clean and disinfect all surfaces and connections as specified earlier in this section. 6. Protect the system from dust and contamination with a plastic cover or other suitable means. Maintenance 7-9

54 8 Product Information Product Warranty All Vetland products are guaranteed to be free of defects for a period of three (3) years from the date of delivery and shall include workmanship and material. The following are exceptions to this warranty: Defects caused by misuse, mishandling or by modifications not authorized by Vetland Medical Sales and Services, LLC. Rubber, plastic and consumable components and materials are warranted to be free of defects at time of delivery. Warranty for the various anesthetic vaporizers as follows: A) For Vetland conversion of Drager Vapor 19.1 ten (10) years, B) Tech3, Tech 4 and Ohio Calibrated vaporizers three (3) years from the date of delivery. Warranty for EX3000 electronics and all other patient monitors is one (1) year. Accessory cables, probes and sensors are for warranted for 90 days. Any product which proves to be defective in workmanship or material will be replaced, credited or repaired at the discretion of Vetland. Vetland is not responsible for normal deterioration, wear and tear or abuse. In any case, Vetland will not be liable beyond the original selling price. Application of this warranty is subject to the following conditions: Merchandise returned for warranty credit or replacement must have been purchased from Vetland within the specified warranty period or proof of installation within that time will be required. Vetland must promptly be notified upon detection of the defective product or material. If the defective product or material cannot be repaired at the customer s site, it must be returned to Vetland, shipping prepaid. Examination of the product or material by Vetland must confirm that the defect is covered by the terms of this warranty. Notification of the defective product or material must be received by Vetland no later than two (2) weeks following the expiration of this warranty. A Returned Goods Authorization number must be obtained from Vetland and shall accompany any equipment being returned under this warranty. Refer to the Returned Goods Policy below. In order to assure complete protection under this warranty, the Warranty Registration Card (if applicable) must be returned to Vetland within ten (10) business days of receipt of the product. The preceding information is the sole warranty provided by Vetland. No other warranty expressed or implied is intended. Representatives of Vetland or its agents are not authorized to modify the terms of this warranty without Vetland s current president s signature of approval. Product Information 8-1

55 Payment Terms Merchandise is shipped pre-paid or COD. FOB Louisville, KY. Net 30 days to customers with established credit. Please contact the Customer Service Department concerning credit information. Shipping All merchandise is sold FOB Louisville, Kentucky. The purchaser accepts these terms upon the issuance of a purchase order. Under the terms of FOB Louisville, Kentucky, all goods become the property of the customer upon Vetland s delivery to its designated freight carrier. It is the responsibility of Vetland to convey the goods to the carrier and provide a clean Bill of Lading (when applicable) or proof of shipment. The customer is responsible for transportation costs. Vetland will assist in any way possible in the event of loss or damage to merchandise and any subsequent claim against the carrier, but the responsibility for reporting such loss or damage and filing any claims remains with the customer. Any shortages or errors in shipment of goods must be reported to Vetland within two (2) weeks of date of shipment in order for corrective action to be taken. All merchandise to be retuned must have prior authorization by Vetland. An authorization number will be issued by Vetland. This number must appear on the label, packing slip, and any other related documents. Goods received without authorization will be refused at Vetland s receiving dock and retuned at customer s expense. Returned Goods Policy When requesting authorization to return merchandise, the following information should be provided: Customer purchase order number and date. Vetland shipping date and method of shipment (see packing slip or bill of lading). Vetland s invoice date and number. Reason for return. The following are accepted reasons for return of merchandise: Defective goods. Customer order error. Vetland order or shipping error. Goods returned are subject to the terms of any applicable warranty. Defective products will be accepted for return only during the warranty period and only when accompanied by a Returned Goods Authorization (RGA) number provided by Vetland. Goods to be returned due to customer s order error must have been received by the customer within thirty (30) days prior to the request for return. They must be received by Vetland within thirty (30) days after the return authorization was issued. These goods must be returned unused in the original shipping container and are subject to a 20% restocking charge. The restocking charge will not be applied for defective goods or those shipped due to Vetland s error. 8-2 Product Information

56 The following merchandise is not eligible for return unless proven to be defective: Merchandise for which no Returned Goods Authorization (RGA) was issued by Vetland. Merchandise specially ordered by, or manufactured for, the customer. Sterile or rubber goods. Used merchandise or products not in the original container. Merchandise held over thirty (30) days from day of receipt by the customer. Merchandise which has been altered or abused. Upon receipt of authorized returned goods an inspection of the merchandise will be conducted and appropriate action will be taken. Vetland s decision regarding deposition of these goods is final. Vetland products in need of factory repair do not require a return authorization. All items to be retuned should be shipped prepaid to: Vetland Medical Sales & Services, LL.C Holloway Road Louisville, KY Attn: Customer Service Department Return Goods Authorization Number (when applicable) Limitation of Liability All Vetland products are ONLY to be used for VETERINARY purposes. Vetland products are not designed to be used for human patients. Vetland s liability whether arising out of or related to manufacture and sale of the goods, their installation, demonstration, sales representation, use, performance, or otherwise, including any liability based upon Vetland s Product Warranty is subject to and limited to the exclusive terms and conditions as forth above, whether based upon breach of warranty or any other cause of action whatsoever, regardless of any fault attributable to Vetland, and regardless of the form of action (including without limitation, breach of warranty, negligence, strict liability or otherwise). The stated Express Warranties are in lieu of all warranties, expressed or implied, including without limitation warranties of merchantability, fitness or any particular purpose or non-infringement. Vetland shall not be liable for, nor shall buyer be entitled to recover any special incidental or consequential damages, or for any liability incurred by buyer to any third party in any way arising out of or relating to the goods. In the unlikely event of a disagreement, the place of venue is Louisville, KY, U.S.A. Product Information 8-3

57 9 Useful Information Overview This section provides information that may be helpful to the users of Landmark Anesthesia Systems. Pressure Equivalents 1 atm = 1033 cmh 2 O = 760 mmhg = 760 Torr = 1013 mb = 14.7 psi 1 psi = 70.3 cmh 2 O = 51.7 mmhg =68.9mb = 6.9 kpa 1 mmhg = 1.36 cmh 2 O = 1.02 mb 1 cmh 2 O = mmhg = mb Pressure Unit Conversions Unit psi inch H 2 0 Table 9-1 Pressure Unit Conversions inch Hg kpa millibar cmh20 mmhg Torr psi inch H x x inch Hg kpa millibar cmh x x mmhg x x Monitored Anesthesia Care (MAC) Anesthetic Levels Table 9-2 MAC Levels Patient Halothane Isoflurane Sevoflurane Cat Dog Horse Useful Information 9-1

58 Miscellaneous Information Table 9-3 Miscellaneous Information Item Tidal Volume Breathing Bag Size Oxygen Flow Oxygen Tanks Size E: Size H: Pressure Regulator Description Approximately 5 to 7 ml per pound of patient weight. Example: 100 pound dog x 5-7 ml per pound = 500 to 700 ml tidal volume Approximately 5 times the tidal volume. Example: tidal volume of 400 ml x 5 = 2 liter bag Non-rebreathing circuits: 100 ml/pound/minute (higher flows for induction; minimum 250 ml Semi-closed rebreathing system: Low Flow 5 to 10 ml/pound/minute High Flow 10 to 50 ml/pound/minute Height: 30 in. Diameter: 3.5 in. Volume: 651 L Initial Pressure: psi Service Duration: Approximately 11 hours at 1.0 liter/minute Note: Does not include O 2 flush time which exceeds the 1.0 L/min rate. Mounting: Can be mounted to a yoke on the anesthesia system stand or small cylinder cart. Advantages: Easily portable to multiple usage areas Can be mounted on the anesthesia system stand Height: 54 in. Diameter: 8.5 in. Volume: 7107 L Initial Pressure: psi Service Duration: Approximately 118 hours at 1.0 liter/minute Note: Does not include O 2 flush time which exceeds the 1.0 L/min rate. Mounting: Mount securely to a large cylinder cart or a solid surface. Advantages: Good when anesthesia system is used in a limited area Needs fewer refills Lower operational cost Must be capable of reducing tank pressure to psi. Note: Do not use a separate flow regulator (already part of the anesthesia system). 9-2 Useful Information

59 Definition of Terms absorbent - A chemical substance such as Litholyme TM that removes carbon dioxide (CO 2 ) from the breathing circuit by a chemical neutralization process which produces carbonates, water, and heat. absorber system - The components of a rebreathing system designed to remove carbon from patient exhaled gas. This includes the inspiratory and expiratory valves, CO 2 absorbent canister, pop-off valve, breathing bag port, and related tubing. anesthesia - Partial or complete loss of sensation with or without loss of consciousness induced by an anesthetic agent. anesthetic agent - A drug that induces anesthesia. anesthetic vaporizer - A device that converts a liquid anesthetic into a gas or vapor. APL valve - See pop-off valve. breathing bag - A reservoir in which fresh gas and exhaled gases including CO 2 are stored during exhalation. breathing circuit - A system that delivers anesthetic gases from the anesthesia apparatus to the patient and also transfers exhaled patient gas to the breathing hag; corrugated hoses with 22 mm inner diameter connections must be used for patient breathing circuits. cc - cubic centimeter -1/1,000 of a liter; also equal to 1 ml (milliliter). check valve - A valve used in pneumatic systems that opens to allow gas flow only in one direction. cmh 2 O - Centimeters of water pressure - A relatively low pressure which is used to measure inspiratory and sometimes expiratory pressures in the breathing circuit (1 psi = 70.3 cmh 2 0). CO 2 - carbon dioxide directional valves - The inspiratory and expiratory valves present in the patient breathing system. DISS - Diameter Index Safety System - A threaded connector system for medical gases, which prevents the incorrect connection of medical gas supply lines to medical gas equipment. endotracheal adapter - A 15 mm tapered adapter which connects the endotracheal tube to the wye connector of the patient s breathing circuit. endotracheal tube - A tube inserted into the patient s trachea for ventilation purposes (e.g. the act of breathing in and out). expiratory flow rate - The rate at which a gas is exhaled (l/min). expiratory time - The time that is required to exhale all of the inhaled gas (tidal volume). expiratory valve - A unidirectional valve with a 22 mm outer diameter hose connector which opens only when the patient exhales. flush button - A valve located prior to the inspiratory port of the anesthesia apparatus which delivers approximately l/min oxygen flow (on Landmark Veterinary Anesthesia Systems) to the patient s breathing circuit for quick oxygenation, while by-passing the anesthetic vaporizer and any other medical gases. fresh gas - The mixture of medical gases and anesthetic vapors to be delivered to the patient hyperventilation - increased ventilation which results in lower CO 2 levels. inspiration - The act of breathing in or drawing gas into the lungs. inspiratory flow rate - The rate at which gas is inhaled (l/min). Useful Information 9-3

60 inspiratory valve - A unidirectional valve with a 22 mm outer diameter hose connector which opens only when the patient inhales. liter - Equals 1,000 milliliters or 1,000 cubic centimeters. L/min - Liters per minute (e.g. total gas flow during one minute). Litholyme TM - Material which retains exhaled carbon dioxide (used in absorber canisters). Product of Allied Healthcare Products, Incorporated. milliliter (ml) - 1/1000 of a liter, also equal to cc (cubic centimeter). mmhg - Millimeters of mercury - A unit of measure for pressure.7 N 2 O - Nitrous oxide O 2 - Oxygen O-ring - An O shaped device that creates a seal between two adjoining surfaces pop-off valve - An adjustable pressure relief valve that releases excess gas to the scavenger system. Also known as an adjustable pressure limiter (APL) valve. pressure gauge - A device used to measure pressure. Pressure gauges used for measuring medical gas supplies are calibrated in psi. Pressure gauges used to measure pressures in the breathing system are calibrated in cmh 2 O. pressure regulator - A device used to reduce the pressure of a gas to the required safe working pressure. psi - (pounds per square inch) - A unit of measure used to measure the pressure of medical gas supply systems such as cylinders or central piping systems. respiration - The process of gas exchange within the body. respiratory cycle - The time interval from the beginning of inspiration to the beginning of the next inspiration. respiratory rate - The number of inspiratory/expiratory cycles per minute. scavenger system - A system that safely removes waste gases from the breathing system. Flexible hoses with 19 mm inner diameter connections must be used for scavenger systems. Also known as a waste gas elimination system (WGES). unidirectional valve - A valve in the patient s breathing circuit which opens only in one direction to gas flow and remains closed to gas flow in the opposite direction. ventilation - The movement of gas in and out of the lungs. ventilator - A device that provides mechanical assisted or controlled ventilation. wye connector - A Y shaped connector which connects the two corrugated 22 mm hoses of the patient breathing circuit to the 15 mm tapered endotracheal adapter. yoke - A device to mount E-size medical gas cylinders (or smaller) to certain medical gas supply systems. 9-4 Useful Information

61 10 Replacement Parts and Accessories Overview This section contains information for ordering replacement materials and parts for your Landmark Anesthesia System. Contact Vetland (phone: , fax: ) or your local distributor to order the materials, parts, and accessories described in this section. Replaceable Materials and Accessories Table 10-1 Replaceable Materials and Accessories Item Order No. Apnea Sensor Pack of A Battery, Reserve Breathing Bag, 0.5 Liter, Latex Free, Disposable Breathing Bag, 1 Liter Breathing Bag, 2 Liter Breathing Bag, 3 Liter Breathing Circuit, Unilimb F 40 with 3 Liter Bag Breathing Circuit, Pediatric Wye Breathing Circuit, Pediatric Unilimb Cleaner, Cavicide 24 oz. Spray F/Air Charcoal Filter Canister Filler Anti-spill, Isoflurane Filler, Key, Isoflurane Filler, Anti-spill, Sevoflurane Filler, Key, Sevoflurane Heat/Moisture Exchangers Small Heat/Moisture Exchangers Medium Heat/Moisture Exchangers Large Landmark Second Vaporizer Side Mount Kit A Litholyme TM CO 2 Absorbent 2.6 lb. (1.18 kg) Bag Litholyme TM CO 2 Absorbent 5 gal. Pail Mask, Canine Small Mask, Canine Large Mask, Canine X-Large Mask, Cat Small Mask, Cat Medium Mask, Cat Large Mask Diaphragm, Small Mask Diaphragm, Large Mayo Tray, Side A Modified Jackson Rees Non-Rebreathing Circuit Manifold, E-Tank Pressure Test Kit A Rubber Goods Kit, Landmark/Ex A Tee, Oxygen Dual Inlet Tee, Vent, Oxygen Drive Replacement Parts and Accessories 10-1

62 Exploded View Drawings The following Landmark Anesthesia System exploded view drawings are provided as an easy reference to identify parts and assemblies for use in maintenance, servicing, and ordering of parts. No. Qty. Parts List Page A Frame Assembly A Gauge Assembly Mayo Tray A Back Panel Assembly A Pole Assembly A Oxygen Flowmeter Assembly A APL / Pop-Off Valve Assembly A Manifold Block Assembly A Absorber Canister Assembly A Flush Valve Assembly A Inspiratory Expiratory Valve Assembly Optional Vaporizer Assembly 24 to 31 Figure 10-1 VSA-2100 Floor Model 10-2 Replacement Parts and Accessories

63 No. Qty. Parts List Page A Gauge Assembly A Right Angle APL / Pop-Off Valve Assembly A Inspiratory Expiratory Valve Assembly A Absorber Canister Assembly A Flush Valve Assembly A Oxygen Flowmeter Assembly Optional Vaporizer Assembly 24 to A Tabletop Frame Assembly A Tabletop Back Cover Assembly A Tabletop Manifold Block Assembly 20 Figure 10-2 VTA-1100 Table Top Machine Replacement Parts and Accessories 10-3

64 No. Qty. Parts List Page A VDA-4100 Frame Assembly A VDA-4100 Back Panel Assembly A Gauge Assembly A Pole Assembly A Oxygen Flowmeter Assembly A APL / Pop-Off Valve Assembly A Manifold Block Assembly A Absorber Canister Assembly A Flush Valve Assembly A Inspiratory Expiratory Valve Assembly A Drawer Assembly Optional Vaporizer Assembly 24 to 31 Figure 10-3 VDA-4100 Doublewide Machine 10-4 Replacement Parts and Accessories

65 Figure A Frame Assembly Replacement Parts and Accessories 10-5

66 Figure A Gauge Assembly 10-6 Replacement Parts and Accessories

67 Figure A Back Panel Assembly Replacement Parts and Accessories 10-7

68 Figure A Pole Assembly 10-8 Replacement Parts and Accessories

69 Figure A Oxygen Flowmeter Assembly Replacement Parts and Accessories 10-9

70 Figure A APL / Pop-off Valve Assembly Replacement Parts and Accessories

71 Figure A Manifold Block Assembly Replacement Parts and Accessories 10-11

72 Figure A Absorber Canister Assembly Replacement Parts and Accessories

73 Figure A Flush Valve Assembly Replacement Parts and Accessories 10-13

74 Figure A Inspiratory Expiratory Valve Assembly Replacement Parts and Accessories

75 Figure A Right Angle APL / Pop-off Valve Assembly Replacement Parts and Accessories 10-15

76 Figure A Tabletop Flush Valve Assembly Replacement Parts and Accessories

77 Figure A Oxygen Flowmeter Assembly Table Top Only Replacement Parts and Accessories 10-17

78 Figure A Tabletop Frame Assembly Replacement Parts and Accessories

79 Figure A Table Top Back Cover Assembly Replacement Parts and Accessories 10-19

80 Figure A Tabletop Manifold Block Assembly Replacement Parts and Accessories

81 Figure A VDA-4100 Frame Assembly Replacement Parts and Accessories 10-21

82 Figure A VDA-4100 Back Panel Assembly Replacement Parts and Accessories

83 Figure A Drawer Assembly Replacement Parts and Accessories 10-23

84 Figure Drager Vaporizer Replacement Parts and Accessories

85 Figure Tec3 Vaporizer Replacement Parts and Accessories 10-25

86 Figure Millimeter Outlet Caps Replacement Parts and Accessories

87 Figure Ohio Vaporizer Replacement Parts and Accessories 10-27

88 Figure Penlon Vaporizer Replacement Parts and Accessories

89 Figure Tec4 Vaporizer Bolt-on Type Replacement Parts and Accessories 10-29

90 Figure Tec 4 Vaporizer Latching Type (1 of 2) Replacement Parts and Accessories

91 Figure Tec 4 Vaporizer Latching Type (2 of 2) Replacement Parts and Accessories 10-31

92 for product and training videos US Toll Free Main

Flow meter. bellow vaporizer. APL valve. Scavenging system

Flow meter. bellow vaporizer. APL valve. Scavenging system Introductory Lecture Series: The Anesthesia Machine PORNSIRI WANNADILOK Objectives Anesthesia Machine Ventilators Scavenging Systems System Checkout 1 Flow meter ventilator bellow vaporizer Corrugated

More information

M5400 Operators Manual

M5400 Operators Manual M5400 Operators Manual For Veterinary Use Only Supera, LLC Copyright 2012 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia Innovations anesthesia machine! We are delighted

More information

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200 Operators Manual Supera Floor Stand Anesthesia Machine Models: M1000 Basic Non-rebreathing M1200 Basic M1000 M1200 (All shown with optional equipment) Copyright Supera, LLC 2017 Examination and Preparation

More information

AUTOVENT 4000 VENTILATOR

AUTOVENT 4000 VENTILATOR OVERVIEW AUTOVENT 4000 Only properly trained and approved Escambia County Bureau of Public Safety Paramedics are to use the AutoVent 4000 ventilator manufactured by LSP to transport patients already on

More information

Anesthesia Machine Intro

Anesthesia Machine Intro Anesthesia Machine Intro Brigham and Women s Hospital New Residents July 9, 2010 Copyright 2000-2010, James H Philip, all rights reserved ADS1 Ready JHP Anesthesia Machine Intro James H. Philip, MEE, MD,

More information

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT) OPERATOR MANUAL Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 M3000 M3100 (SHOWN WITH OPTIONAL EQUIPMENT) 12330 SE Hwy 212 Clackamas, Oregon 97015 (503) 822-1157 Local and International

More information

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting This is a quick reference for setting up, using, and troubleshooting the Hallowell EMC 2000 and 2002 Small Animal Ventilator.

More information

Anes Machine Use and Pre-use Check - CA1 focus

Anes Machine Use and Pre-use Check - CA1 focus Anes Machine Use and Pre-use Check - CA1 focus BWH Anesthesia Grand Rounds August 31, 2005 James H. Philip, MEE, MD, CCE Copyright 2000-2005, James H Philip, all rights reserved BWH Anesthesia Workspace

More information

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500 Operators Manual Supera Wall Mount Anesthesia Machines Models: M2300 M2500 (All shown with optional equipment) M2300 M2500 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia

More information

Hallowell EMC Anesthesia WorkStation Operating Manual

Hallowell EMC Anesthesia WorkStation Operating Manual Hallowell EMC Anesthesia WorkStation Operating Manual PN 000a2770 Anesthesia WorkStation A compact (9" W x 9" D x 15" H), convenient system for use on animals under 7 kg (15 lb.) Hallowell Engineering

More information

Anesthesia. Midmark Animal Health Products

Anesthesia. Midmark Animal Health Products Anesthesia Midmark Animal Health Products The first and still the best. Safe, simple and controllable inhalation anesthesia Matrx anesthesia machines are the number one choice of veterinary professionals

More information

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee Wake Forest University Baptist Medical Center Department of Anesthesiology TECHNICIAN ABBREVIATED CHECKLIST OF RESPONSIBILITIES For Anesthesia Apparatus Checkout Specific to the Draeger APOLLO anesthesia

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

Draeger Fabius GS Pre-Use Check

Draeger Fabius GS Pre-Use Check Draeger Fabius GS Pre-Use Check James H Philip MEE, MD, CCE 2011 James H Philip All rights reserved Remember to enter Machine # Fabius GS front view Fabius GS pre-use checkout procedure Fabius GS pre-use

More information

VAPOMATIC ANESTHETIC VAPORIZER

VAPOMATIC ANESTHETIC VAPORIZER VAPOMATIC ANESTHETIC VAPORIZER INSTRUCTION MANUAL SOLD FOR VETERINARY USE ONLY BY: A.M. BICKFORD, INC. 12318 BIG TREE ROAD WALES CENTER, NY 14169 1-800-795-3062 Fax: 716-652-2046 www.ambickford.com sales@ambickford.com

More information

Rev. B. Operating Instructions

Rev. B. Operating Instructions 780745-00 Rev. B Operating Instructions 780745-00 Rev. B TABLE OF CONTENTS PAGE Warnings, Cautions, and Notes..............................4-7 Definition of Symbols......................................

More information

Pressure Regulator. Instructions for Use

Pressure Regulator. Instructions for Use Pressure Regulator Instructions for Use 702-0083.9 December 2017 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in injury to the patient, the

More information

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage

More information

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be

More information

AIR/OVER HYDRAULIC JACK 20 TON

AIR/OVER HYDRAULIC JACK 20 TON AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.

More information

Hallowell EMC Vacuum / Scavenging Interface

Hallowell EMC Vacuum / Scavenging Interface Hallowell EMC Vacuum / Scavenging Interface For use in veterinary medical applications only. Operating Manual and Scavenging Primer with Receiving Information, Installation and Maintenance Instructions

More information

Anesthesiology Research and Scholarship. Follow this and additional works at:

Anesthesiology Research and Scholarship. Follow this and additional works at: University of New Mexico UNM Digital Repository Anesthesiology Research and Scholarship Anesthesiology 9-1-2013 Breathing Systems Janet Brierley Follow this and additional works at: https://digitalrepository.unm.edu/anesthesiology_pubs

More information

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use Oxygen Dialflow Meter Instructions for Use 702-0031.9 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

SurgiVet Universal CDS 9000 Small Animal Anesthesia Machine Operation Manual

SurgiVet Universal CDS 9000 Small Animal Anesthesia Machine Operation Manual TM SurgiVet Universal CDS 9000 Small Animal Anesthesia Machine Operation Manual - English Catalog Number WW V1932 Version 0, January 2009 2009 Smiths Medical family of companies. All rights reserved. Table

More information

Aespire 7100 Essential performance Compact design

Aespire 7100 Essential performance Compact design GE Healthcare Aespire 7100 Essential performance Compact design Features Enhanced monitor integration capabilities with our Datex-Ohmeda Anesthesia Monitor and Compact Anesthesia monitor Lightweight and

More information

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

PORTER INSTRUMENT COMPANY, INC.

PORTER INSTRUMENT COMPANY, INC. PORTER INSTRUMENT COMPANY, INC. MXR FLOWMETER Instructions and Safety Considerations MXR Models of Porter Conscious Sedation Flowmeters and Bag Tee (Accessory) Wall Mount Models: 2000 and 2000-OS, 3000

More information

1 DRIVE INDUSTRIAL IMPACT WRENCH

1 DRIVE INDUSTRIAL IMPACT WRENCH 1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight

More information

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS Parker Hannifin Corporation Precision Fluidics Division Porter Instrument 245 Township Line Road Hatfield, PA 9440 Office 25-723-4000/Fax 25-723-506 www.porterinstrument.com 2 CYLINDER MOBILE CART USER

More information

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

XpressFill XF2500 Counter Pressure Filler. Operating Instructions XpressFill XF2500 Counter Pressure Filler Operating Instructions ii XPRESSFILL Systems LLC lling machine. ank you for choosing our handcrafted bottle filler as the technology to bottle your passion. We

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this

More information

Interface Devices, Inc. Hydraulic Mini Mule

Interface Devices, Inc. Hydraulic Mini Mule Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

300 Held Drive Northampton Pa

300 Held Drive Northampton Pa 300 Held Drive Northampton Pa 18067 610.262.6090 June 10, 2015 Recommended testing for verifying device performance. Intervals of testing are to be set by the Healthcare Provider / Dealer. Table of Contents

More information

HPB25 Hydraulic Paving Breaker

HPB25 Hydraulic Paving Breaker INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS COMPACT TRIPLE WALL OUTLET STATION MODEL 6255-1 INSTALLATION AND OPERATING INSTRUCTIONS To assure safe operation and conformation to local fire codes, all Porter Outlet Stations are designed to be used

More information

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1 ANA 74300 Oxygen Regulator with Yoke Connector User Manual Manual No. ANA 74300 001 Issue 1 Safety Thank you for purchasing this Clements Oxygen Regulator. For your safety it is imperative that this unit

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

ACRYLIC FLOW METERS 0-30, 0-70 & LPM ACRYLIC FLOW METERS 0-30, 0-70 & 0-120 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P86 (0-120LPM) R219P87 (0-70LPM) R219P88 (0-30 LPM) R138P11 Rev. D TABLE OF CONTENTS: 1.0 PRODUCT OVERVIEW...1

More information

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

AIR/OXYGEN BLENDER INSTRUCTION MANUAL BIO-MED DEVICES AIR/OXYGEN BLENDER INSTRUCTION MANUAL CATALOG #2120 REV 042203 BIO-MED DEVICES INC. 1445 BOSTON POST ROAD, GUILFORD, CT 06437 (203) 458-0202 FAX (203) 458-0440 www.biomeddevices.com TABLE

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Dialflow Regulator. Instructions for Use

Dialflow Regulator. Instructions for Use Dialflow Regulator Instructions for Use 702-0030.11 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

PRESSURISED PAINT CONTAINER

PRESSURISED PAINT CONTAINER PRESSURISED PAINT CONTAINER MODEL NO: CPP2B PART NO: 3082115 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE Pressurised Paint Container. Before attempting

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS TM controlled ventilation Equinox II NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E USER TABLE OF CONTENTS CHAPTER TITLE PAGE 1 INTRODUCTION 1.1 Equinox II Administration

More information

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC. MANUFACTURERS AND DISTRIBUTORS OF: O-Two eseries Electronic Transport Ventilators O-Two Single Use Open CPAP Systems O-Two CAREvent Range of Automatic Transport Ventilators O-Two CAREvent Range of Automatic

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS 1. INTRODUCTION An anaesthesia delivery system includes any machine, equipment or apparatus which supplies gases, vapours, local anaesthesia and/or

More information

Pressure Regulators. Instructions for Use

Pressure Regulators. Instructions for Use Pressure Regulators Instructions for Use 702-0032.11 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to

More information

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the Anesthesia Machine The Anesthesia Machine You are the master of the machine You are responsible for checking the machine prior to each case 1 The Anesthesia Machine (con t) The primary cause of machine

More information

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No Operator s Manual with Maintenance Schedule Fourth Edition Second Printing Part No. 82297 Operator s Manual Fourth Edition Second Printing Important Read, understand and obey these safety rules and operating

More information

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators Genstar Technologies Co., Inc. 4525 Edison Avenue Chino, CA 91710 USA TEL 909-0-272 FAX 909-0-485

More information

Portable Compressed CO 2 Regulator

Portable Compressed CO 2 Regulator Portable Compressed CO 2 Regulator 99901 Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR OXYLATOR FR-300 RESUSCITATOR Symbols used in the Operating Manual for the Oxylator FR-300 and/or on the Oxylator FR-300 unit: WARNING! Do not use grease or

More information

NARKOVET ANAESTHETIC UNIT

NARKOVET ANAESTHETIC UNIT NARKOVET ANAESTHETIC UNIT MANUAL Art. No. 213062 TELEPHONE +49 7461 96 580 0 www.eickemeyer.com Table of Contents 1 Description...4 2 Overview of the Device...4 3 Startup Procedure...5 4 Operation of

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

Keeping anaesthetic pollution to minimum in theatre environment

Keeping anaesthetic pollution to minimum in theatre environment Vet Times The website for the veterinary profession https://www.vettimes.co.uk Keeping anaesthetic pollution to minimum in theatre environment Author : Gianluca Bini Categories : General, Vets Date : September

More information

Operation and Maintenance of the EPV200 Portable Ventilator

Operation and Maintenance of the EPV200 Portable Ventilator Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll

More information

Installation of Your SprayMaster System

Installation of Your SprayMaster System Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each

More information

Pressure Regulators. Operating Instructions. Instrumentation

Pressure Regulators. Operating Instructions. Instrumentation Pressure Regulators Operating Instructions FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Micro Dial-Flowmeter. Instructions for Use

Micro Dial-Flowmeter. Instructions for Use Micro Dial-Flowmeter Instructions for Use 702-0082.8 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

Recommendations on Checking Anaesthesia Delivery Systems

Recommendations on Checking Anaesthesia Delivery Systems Page 1 of 11 Recommendations on Checking Anaesthesia Delivery Version Effective Date 1 Oct 1992 (reviewed Feb 07, Feb 02) 2 2004 3 Nov 2011 4 Dec 2016 Document No. HKCA T1 v4 Prepared by College Guidelines

More information

CS150 CAP STAPLER OWNER S MANUAL

CS150 CAP STAPLER OWNER S MANUAL Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER

More information

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) 0-3, 0-15, 0-30 & 0-70 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P87-400 (0-70 LPM) R219P88-400 (0-30 LPM) R219P79-400 (0-15 LPM) R219P99-400

More information

Advanced Fluid Handling Cart Owner s Manual

Advanced Fluid Handling Cart Owner s Manual Advanced Fluid Handling Cart IMPORTANT Please read this carefully and thoroughly before installing and operating your Advanced Fluid Handling Cart. Please retain this owner s manual for future reference

More information

CPR MEDICAL DEVICES INC. OPERATING MANUAL

CPR MEDICAL DEVICES INC. OPERATING MANUAL CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR OXYLATOR EMX RESUSCITATION AND INHALATION SYSTEM Symbols used in the Operating Manual for the OXYLATOR EMX and/or on the OXYLATOR EMX unit: WARNING! Do not

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the

More information

WARNING: FOR OUTDOOR USE ONLY

WARNING: FOR OUTDOOR USE ONLY Certified to CSA International 4.96 US For Outdoor Gas Fireplaces A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND BEAUTIFUL OUTDOOR LARGO FIRE PIT FOR PROPANE AND *NATURAL GAS OWNER S MANUAL WARNING:

More information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model

More information

Welcome to the Specialized Medical Services Respiratory training webinar series!

Welcome to the Specialized Medical Services Respiratory training webinar series! Welcome to the Specialized Medical Services Respiratory training webinar series! SMS is your Long Term Care (LTC) facility single source for oxygen, medical equipment, respiratory care services and supplies

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

Instructions for Cleaning & Maintaining Air Compressor

Instructions for Cleaning & Maintaining Air Compressor Instructions for Cleaning & Maintaining Air Compressor 1. The air compressor should be kept at least 6-8 inches away from the wall for ventilation and to keep the compressor from overheating. 2. The compressor

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET

More information

Our technical information is based on Tip: calls attention to special information.

Our technical information is based on Tip: calls attention to special information. SUPPLY TANKS (CBP) 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding to install

More information

User Guide and Operating Manual

User Guide and Operating Manual User Guide and Operating Manual Table Top Laboratory Animal Anesthesia System 901806 & Mobile Laboratory Animal Anesthesia System 901807 / 901809 VetEquip, Inc. - Pleasanton, California USA - 800-466-6463

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 405-282-8105 www.autoquip.com Item # 830ABS Version 1.0 07/2001

More information