CASE STUDIES IN BOILER VIBRATIONS AND BFP CAVITATION

Size: px
Start display at page:

Download "CASE STUDIES IN BOILER VIBRATIONS AND BFP CAVITATION"

Transcription

1 CASE STUDIES IN BOILER VIBRATIONS AND BFP CAVITATION By K.K.Parthiban, B.Tech ( IIT-M), M.E Thermal Engineering- RECT Trichy In this paper two case studies are presented, which are relevant to boiler operating and design engineers. One is a vibration problems experienced in CFBC boilers and other is about a repeated BFP failure in a power plant. VIBRATION OF SECOND PASS AT AIRPREHEATER There were three cases which had come to us in this subject. Two cases were about the vibration experienced in the APH casing of CFBC boilers. One case is the vibration of the steam cooled second pass housing the primary superheater & economiser. Vibration of boiler is not a rare phenomenon and many readers would have come across it. Vibrations of tube bundles / casing / panels are due to a scientific phenomenon known as flow induced vibration. Some of us may doubt whether fluid flow can cause vibration. Here is a famous example. The two photos below show the collapse of a bridge named Tacoma Narrows Bridge in USA in the year Within three months Photo 1 & 2 : Collapse of Tacoma narrows bridge of construction, the bridge collapsed due to aero-elastic flutter due to wind at a speed of 68 kmph. This phenomenon is due to flow of wind around the bridge. The subject is unique and such situations occur in boilers too. Vibration and noise problems may be encountered as the air / gas / water / steam flow over tube bundles in a power plant. Fig 1: Von korman street- is a repeating pattern of swirling vortices caused by the unsteady separation of flow over bluff bodies Vortices are formed and shed beyond the wake of the tubes, resulting in harmonically varying forces on the tubes perpendicular to the flow direction. It is a self-excited vibration. If the frequency of vibration of the Von-Karman vortices, as they are called, coincide with the natural frequency of vibration of the tube bank, resonance occurs which leads to tube vibration. Another phenomenon that is relevant for discussion here is acoustic vibration, leading to noise. The duct or the waterwall / steam cooled panels vibrate when the acoustic frequency coincides with the natural frequency of tubes. The acoustic oscillation is normal to both

2 The casing vibration can lead to supporting structure and hand rails. It becomes Figure 2: Picture of standing wave in a duct / enclosure, due to air / gas necessary to column. identify the source of acoustics. In boiler and duct systems the source of acoustics can be from fans, improper ducts, and abrupt transitions, to list a few. Case study 1: vibration of APH casing in a CFBC boiler This is a 76 TPH CFBC boiler designed to fire 45% ash Indian coal. The boiler general arrangement can be seen in figure 3 below. The 2 nd pass APH casing was seen to vibrate heavily once the load crossed 65 TPH. The APH casing started cracking on the heavy vibration. The boiler was inspected during operation. Plant engineers had stiffened the duct casing, thinking that the duct stiffeners are inadequate. Even after the additional stiffening of the casing, the casing was cracking. See photo 3 & 4 below. On shut down inspection, it became clear that the cause for vibration was the acoustics created by the air leak from air side to gas side. Heavy air leak could be seen from the lifting holes of APH blocks. See photo 5 & 6. Figure 3: CFBC boiler Case study 1 Photo 3 & 4: APH casing cracks.

3 Photo 5 & 6: APH casing cracks can be seen due to acoustic vibration. The source of vibration was the high pressure air leak from air side to casing side through the lifting lugs. Photo 7 at top left shows the excessive gap between the casing and the end tube. Photos 8 shows the incomplete seal welding around the APH blocks. Figures 4 & 5 below show the erection welds. In shut down, more leakages were seen between the APH base and the structural supports. The vibration possibilities due to vortex shedding and standing waves were checked, by calculations. The procedure for checking the vortex induced vibration and the acoustic vibration is well written by Mr.V.Ganapathy, expert in heat transfer. There was no possibility of APH tube vibration. Readers could refer his article in internet. The spread sheet calculations is presented in this article for reader s interest. Another observation was that the tube to casing gap was much higher than the tube to tube clear gap. This can lead preferential gas flow along the casing and cause casing vibration. Perforated plates were installed at these locations, so that ash would not bridge and the gas flow would be retarded. The vibration stopped once all the actions were taken as per the recommendations.

4

5 Case study 2: vibration of second pass in a 270 TPH CFBC boiler The case is a CFBC boiler of 270 TPH with Indonesian coal as the fuel. See figure 6 showing the boiler layout. As the steam generation was increased around 80% MCR, the second pass began to vibrate. The boiler maker suggested dividing the gas path thinking that there is superheater coil vibration due to acoustics. When the visit was made, we found there could be other causes which needed to be attended first before implementing the gas side partitioning proposed by the boiler maker. Our observations included the following. Air was seen gushing in the soot blower stuffing box making a whistle noise. This was later attended by the plant engineers. The oxygen levels were also high. The CFBC operation was not stabilized with adequate dust in the upper furnace. There would be combustion pulsations which lead to vibration. Vibration was experienced at another plant, when O 2 level was at 12% in flue gas. We did notice that there was air ingress in the fabric joint flange, wherein sealing rope was used. The flange was not rigid too. We advised the flange be seal welded. Internal bracings were added at the flange frame. The boiler operation was corrected by proper loop seal parameters and adequate upper furnace dust. Vibration was gone after the modifications.

6 Figure 6: General arrangement of the 270 TPH CFBC boiler which had developed vibration in the second pass.

7 A clip from literature on vortex induced vibration and acoustic vibration modes. Gas flows / air flows in a heat exchanger bank can generate a loud noise called acoustic resonance. The noise can occur when the frequency of flow periodicity generated in the array resonates with one of the natural transverse acoustic standing waves of the duct. The relevant standing waves are oriented in a direction normal to both the tube axis and the flow direction. When resonance occurs an intense pure tone noise is usually produces that can cause damage to the HX internals by fatigue and will be harmful to plant personnel. The loudness of the noise can reach up to 175 db, depending upon the pressure drop of the tube array and the damping capacity of the tube bundle and the duct. The most common remedy is to install one or more anti-resonant baffles within the tube bundle to distort and suppress the resonance acoustic waves. Photo 9 & 10 show the position of the large fabric joint just below the economiser, which deflected inside and created air ingress. The internal tie pipes were added to prevent the caving of the flange. The flanges were seal welded. When the unit was put back on line, there was vibration. Acoustic disturbances can be in many forms. Air ingress also seem to create more problem in CFBC as the negative draft is high in the second pass as compared to other stoker / AFBC or even PF boilers. In fact the doors in the second pass had to be sealed well. Incidentally this boiler is provided with perforated baffles to prevent the preferential flow of the gases close to the casing / steam cooled wall.

8 CASE STUDY 3: FEED PUMP CAVITATION In this case, the BFP had been subject to cavitation damage during turbine trip / load throw occasions. The deaerator is given steam from the turbine extraction in order to maintain the feed water temperature at 160 deg C. This corresponds to operating pressure of 5.2 kg/cm2 g. When a load throw occurred in the turbine, the deaerator pressure comes down. During this period the NPSH is upset. The pump supplier had informed the plant engineers that the suction piping pressure drop is too high and hence the cavitation has been occurring. Plant engineers had made arrangements are to inject cold condensate from the CEP. But the basic problem remained. The various data for every second was available with plant engineers as this problem had been a seven year old problem for the plant. Why should there be a cavitation when the pressure drops at deaerator? During a transient condition the volume of water trapped in the suction piping is at a higher temperature as compared to the deaerator tank water temperature. The temperature of water at deaerator storage tank would be at the saturation temperature corresponding to current pressure above water level. In the event of turbine trip, the deaerator tank pressure will drop. The hot water at storage tank will produce flash steam in case of pressure drop and adjust its temperature. But the temperature sensors would indicate slow change. It is the trapped water in suction piping that can cause cavitation. It can be about 60 seconds for the water to be replaced, with the feed water flow rate present after the load reduction. It is within this period that the cavitation damage could occur. Any vibration in BFP should be in this period only. Once the water inside the suction piping is replaced, there should not be any continuity of cavitation or vibration. Our diagnosis points First thing was the pressure drop calculation for the suction piping. The pressure drop in suction piping with boiler MCR flow was calculated to be only 0.23 mwc. The truth was that the pump maker did not make a calculation or measured the pressure drop with calibrated pressure gauge. The pump suction strainer DP was seen to be 750 mmwc normally. This is considered to be high in a stabilized plant operation. The DP transmitter was calibrated to 5000 mmwc. The set pressure for alarm as per BFP supplier document was 0.35 kg/cm2. Trip was to be set at 0.5 kg/cm2. Plant engineers had set the trip at 1200 mmwc. Perhaps this was done after the failures were experienced in the BFP. The strainer DP was seen to increase at every load throw in the past. Whenever there was reduction in boiler feed water flow, there was an increase in DP. See photo 11 to 14. This indicates there is ARC passing. The DP rise had been instant, that this was not due to flashing. The ARC may be passing more flow than the stipulated minimum. ARC is designed to relieve 33 m3/h and act at a pressure of kg/cm2 as the FCV starts closing. In the past instances the pressure had never touched the kg/cm2 value, but there is sufficient rise in the strainer DP. This indicates there is passing of ARC at a lower pressure itself. More flow will call for higher NPSH. The available NPSH declines as the turbine load reduces, due to reduction of deaerator pressure. ARC was seen to be passing at the time of visit. The ARC outlet piping temperature at turbine hall was seen to be 138 deg C as measured by the IR camera. This was seen when the feed water

9 flow was 80% of MCR and the BFP discharge pressure was 125 kg/cm2. We suggested adding a pressure gauge near the TG floor in the ARC discharge line to know the passing of ARC. Power consumption is also an issue with passing ARC. We looked in to the details of strainers provided by the pump supplier as the normal DP itself was high. Strainer flow area was seen to be 1.5 times the cross sectional area of piping. We compared the area with strainer design by a well known pump supplier. Their BFPs are provided with 3 times the flow area of piping. We went in to further details of mesh selection. The mesh opening was mm square. The usual strainer openings by another pump supplier used to be 0.5 mm sq. Small mesh openings can also be reason for cavitation. We looked in to the suction piping arrangement taken by plant engineers in the previous occasions. The feed pumps suction tapping at deaerator storage tank was found located near the ring stiffener. This could affect the flow. See photo 16 & 17. We advised to trim the part of stiffener which could obstruct the flow. We recommended that the wire mesh area at inlet shall also be equal to thrice the flow area of the piping. It was advised that the wire mesh openings should be made bigger as it was required only to trap the spray nozzle components. We made this suggestion by comparing with another deaerator in the same plant. Review of the transient curves given by the plant engineers With the latest DCS control system in place, nice transient curves were taken out by the plant engineers in the past. These curves are presented in this paper for readers interest. Such data could help the plant engineers to improve the analytical skills. The transient curve on TG load, deaerator pressure, BFP suction pressure, BFP vibration on 31/8/ AM was reviewed. The curve is attached in photo 11. The load throw (from 25 MW to 15 MW) occurred at about 5.46 AM. Both deaerator pressure and BFP suction pressure had come down and recovered after the pegging steam supply was commenced. In 30 seconds the difference between the suction pressure and deaerator pressure was re-established. The deaerator pressure change had been only 0.7 kg/cm2. But the vibration level had gone up and remained for a longer duration. It seemed to follow the frequency / rpm rise in the drive. The transient curve on TG load, deaerator pressure, BFP suction pressure, BFP vibration on 30/8/ PM was reviewed. The curve is attached in photo 12. The load throw (from 22 MW to 11 MW) occurred at about PM. Both deaerator pressure and BFP suction pressure had come down and recovered after the pegging steam supply was commenced. In 90 seconds the difference between the suction pressure and deaerator pressure was re-established. The deaerator pressure change had been only kg/cm2. But the vibration level had gone up and remained for a longer duration. It followed the frequency / rpm rise in the drive. In this case the suction pressure came below the deaerator pressure and lasted for 1.5 minutes. This is the case of cavitation. In both the above cases, there is a small change in deaerator pressure. The change is about 3 to 7 mwc in head. The NPSH available excluding the strainer DP is mwc. If the pressure decay is too fast then there will be flashing of steam in suction piping. If we assume 1 kg/cm2 is the decay, the flash steam percentage is 1.4%.

10 Photo 11: Both BFP suction pressure and deaerator pressure declined during the load throw. The BFP suction pressure to deaerator pressure difference is maintained.

11 Photo 12: The BFP suction pressure had gone down below that of deaerator pressure. This can happen due to high DP across strainer / ARC acting or due to momentary frequency raise.

12 Photo 13: The DP had gone to 1325 mmwc instantly, even when the water flow is 90 TPH. There is a load throw of 24 to 20 MW. In one minute the deaerator pressure had come down by 0.7 kg/cm2.

13 Photo 14: The BFP strainer DP went up when the steam flow was dropped. Photo 15: The ARC back pressure considered is 12 bar. This may be checked by installing a pressure gauge downstream of ARC. ARC should operate only at kg/cm2 as per the data sheet. The minimum flow for ARC is 33 m3/h.

14 Photo 16 & 17: The photo on the left shows the suction pipe location in the deaerator. The stiffener should be trimmed. The coarse mesh flow area shall be 3 times that of pipe c/s area. Photo on the right shows the coarse strainer in another deaerator of the same plant. Photo 18 & 19: The photos above show passing of ARC valve. The heat is seen in the piping. Photo 20 & 21: The photo on the left shows the strainer DP in another plant and the photo on the right shows the DP in the affected pumps. It implied the strainer flow area is less as compared to other installation.

15 Conclusions The ARC passing, small mesh in strainer, less flow area in strainer could reduce the NPSH available during transients. We recommended two important points for immediate implementations. Pressure decay can be reduced in the make up from CEP is stopped at the deaerator for one minute, the flashing of steam in the water entrapped in suction piping can be reduced. The deaerator vent pipes at this plant were 2 nos of 40 nb lines. We recommended adding 1 x 15 nb parallel vents to reduce the loss of steam and to reduce the rate of decay. M/S Venus energy audit system Trouble shooting of boiler failures and operational issues. Company carries out design audit, construction audit, shut down audit and operational audit. M/S Sri Devi engineering consultancy and agency engaged in non pressure parts spares supply for FBC boilers. K.K.Parthiban M/S Sri Devi boiler equipment and spares engaged in supply of pressure part spares for all type of boilers

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators SMART Explosion Efficient Boiler Cleaning with Explosion Generators Problem and Solution The use of solid fuels, such as coal, waste or biomass, is liable to intense fouling of the steam generator heating

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Pressure Reducing & Desuperheating (PRDS) Station Pressure Reducing (PRS) Station Desuperheating (DSH) Station. Ver. 1.1 (2016)

Pressure Reducing & Desuperheating (PRDS) Station Pressure Reducing (PRS) Station Desuperheating (DSH) Station. Ver. 1.1 (2016) Pressure Reducing & Desuperheating (PRDS) Station Pressure Reducing (PRS) Station Desuperheating (DSH) Station Ver. 1.1 (2016) Pressure Reducing & Desuperheating (PRDS) Station Modular Ready-to-Fit Conditioning

More information

Operating Instructions

Operating Instructions Operating Instructions Before operating the thin film evaporator, please be aware of all safety concerns associated with this experiment: Burn hazard from the column and steam lines, Chemical hazards associated

More information

SGA REDUCTION OF PA & ID FAN LOADING

SGA REDUCTION OF PA & ID FAN LOADING SGA REDUCTION OF PA & ID FAN LOADING Project: Reduction of PA and ID fan loading Baseline: 1. PA Fan 1265 KW 2.ID Fan 1844 KW Target: 1. PA Fan 1215 KW 2.ID Fan 1800 KW Resources - Team Members Name Role

More information

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC!

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC! OUTLINE TACOMA NARROWS BRIDGE FLOW REGIME PAST A CYLINDER VORTEX SHEDDING MODES OF VORTEX SHEDDING PARALLEL & OBLIQUE FLOW PAST A SPHERE AND A CUBE SUMMARY TACOMA NARROWS BRIDGE, USA THE BRIDGE COLLAPSED

More information

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their

More information

DF1 and DF2 Diffusers

DF1 and DF2 Diffusers 1550650/4 IM-P155-07 ST Issue 4 and Diffusers Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance

More information

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers The PRB Coal Users Group plans to develop a Design Guide for Mill Inerting as an aid to users when designing a mill inerting system.

More information

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 6250250/1 IM-P625-03 ST Issue 1 USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 1. General safety information 2. General product information

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) IB-77 Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) These installation, operation and technical instructions should be used by experienced personnel as a

More information

TSS21 Sealed Thermostatic Steam Tracer Trap

TSS21 Sealed Thermostatic Steam Tracer Trap 1255050/4 IM-P125-10 ST Issue 4 TSS21 Sealed Thermostatic Steam Tracer Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Fisher DVI Desuperheater Venturi Inline

Fisher DVI Desuperheater Venturi Inline Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...

More information

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors 1130050/4 IM-P113-02 ST Issue 4 UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap 1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng.  January 2003 THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. www.lightmypump.com January 2003 Synopsis The objective of this article is to explain how a siphon works. The difference between low pressure, atmospheric

More information

FAULT DIAGNOSIS IN DEAERATOR USING FUZZY LOGIC

FAULT DIAGNOSIS IN DEAERATOR USING FUZZY LOGIC Fault diagnosis in deaerator using fuzzy logic 19 FAULT DIAGNOSIS IN DEAERATOR USING FUZZY LOGIC S.Srinivasan 1), P.Kanagasabapathy 1), N.Selvaganesan 2) 1) Department of Instrumentation Engineering, MIT

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Vibration and Pulsation Analysis and Solutions

Vibration and Pulsation Analysis and Solutions 1 Vibration and Pulsation Analysis and Solutions Brian Howes, M.Sc., P.Eng. Beta Machinery Analysis Ltd. Problems created by excessive vibration in machinery can have serious economic impact. Frequently

More information

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

IFTGS14 Ball Float Steam Trap ½ and ¾ with Integral Spiratec Sensor 6150350/3 IM-P615-12 ST Issue 3 IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex

More information

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

FTGS14 Ball Float Steam Trap DN15 (½) to DN25 (1) 1458050/5 IM-P145-12 ST Issue 5 FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1") Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

QuickHeat TM Packaged Heat Exchanger Solutions

QuickHeat TM Packaged Heat Exchanger Solutions 4831999/1 IM-P483-03 CH Issue 1 QuickHeat TM Packaged Heat Exchanger Solutions Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web   Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 981-4500 Facsimile (805) 981-4501 I. Installation Instructions Installation And Operating

More information

THE INFLOW OF UNWANTED AIR

THE INFLOW OF UNWANTED AIR IN PRESSURIZED PIPES The main reason for the inflow of air in public water distribution systems is excessive water velocity. Air traveling with water in pressurized pipes can result in high turbulence

More information

THE TACOMA NARROWS BRIDGE FAILURE Revision A

THE TACOMA NARROWS BRIDGE FAILURE Revision A By Tom Irvine Email: tomirvine@aol.com December 29, 1999 THE TACOMA NARROWS BRIDGE FAILURE Revision A Introduction The original Tacoma Narrows Bridge was opened to traffic on July 1, 1940. It was located

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Operating Instructions

Operating Instructions Operating Instructions Note: 1. Never let the centrifugal pump run dry. 2. Make sure that there is at least one open path for water flow in the pipe network before turning the pump on. Never run the pump

More information

SRI Jigger Tubes System

SRI Jigger Tubes System SRI Jigger Tubes System Design, Installation and Commissioning Manual (Abbreviated Version) INDEX This manual details how the SRI Jigger Tubes System can be tailored to suit the needs of a variety of vacuum

More information

Proper Pump Installation Practices

Proper Pump Installation Practices Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment

More information

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats 0686550/4 IM-P068-58 ST Issue 4 TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions 1234150/3 IM-P123-17 ST Issue 3 AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4.

More information

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

On-Stream Tightness Testing of Vacuum Process Installations

On-Stream Tightness Testing of Vacuum Process Installations ECNDT 2006 - Tu.2.6.3 On-Stream Tightness Testing of Vacuum Process Installations André de JONGE, Leak Detection Group, DCI Meettechniek B.V., Kapelle, The Netherlands DCI Meettechniek. -DCI was founded

More information

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions 0670350/4 IM-S03-11 ST Issue 4 HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information HM Series 3. Installation 4. Commissioning

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels A complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves 4059051/1 IM-P405-48 AB Issue 1 KBV21i and KBV40i Air Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. 17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower

More information

Design DSA Steam-Atomized Desuperheater

Design DSA Steam-Atomized Desuperheater Instruction Manual DSA Desuperheater Design DSA Steam-Atomized Desuperheater Contents Introduction............................... 1 Scope of Manual......................... 1 Description..............................

More information

Pressure Reducing Valve for Steam Type 2333 A

Pressure Reducing Valve for Steam Type 2333 A Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1270750/7 IM-P127-02 ST Issue 7 UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1 General safety information 2 General

More information

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions 1430050/1 IM-P143-04 ST Issue 1 FT16 Ball Float Steam Trap Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation ½" and ¾" shown 4 Commissioning

More information

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam Instruction Manual B&O 0-4-0 WITH SLOPE BACK TENDER Live Steam AML is proud to offer the famous B&O 0-4-0 of the Baltimore Waterfront. Four switchers were built in 1912 by Baldwin for the B&O. Initially

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) WYE Type Strainers. To ensure efficient and safe operation of Titan FCI

More information

Similarly to elastic waves, sound and other propagated waves are graphically shown by the graph:

Similarly to elastic waves, sound and other propagated waves are graphically shown by the graph: Phys 300/301 Physics: Algebra/Trig Eugene Hecht, 3e. Prepared 01/24/06 11.0 Waves & Sounds There are two fundamental waves of transporting energy and momentum: particles and waves. While they seem opposites,

More information

DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA. Ujjwal Chowdhury KD Yadav LD Sahoo

DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA. Ujjwal Chowdhury KD Yadav LD Sahoo DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA Ujjwal Chowdhury KD Yadav LD Sahoo Typical Ash Distribution In a Boiler Typical Dry Fly Ash Handling Arrangement at a Power

More information

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators 0231150/8 IM-P023-55 ST Issue 8 S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

NORMAL OPERATING PROCEDURES Operating Parameter Information

NORMAL OPERATING PROCEDURES Operating Parameter Information Operating Parameter Information Each operator performing the normal operating procedures (routine checks) of the facility should be familiar with the current normal operating parameters of all systems

More information

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions 0685255/1 IM-P068-47 ST Issue 1 TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation

More information

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants Proceedings World Geothermal Congress 2015 Melbourne, Australia, 19-25 April 2015 Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants Kevin Koorey, Kim Harwood and Norman Lawgun

More information

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps... Table of Contents Lesson One Lesson Two Basic Pumping Concepts...3 Maintaining Packing and Seals...19 Lesson Three Maintaining Centrifugal Pumps...37 Lesson Four Overhauling Centrifugal Pumps...53 Lesson

More information

Design process to evaluate potential of wind noise at façade elements

Design process to evaluate potential of wind noise at façade elements Design process to evaluate potential of wind noise at façade elements Dr.Cristina Paduano 1, Dr.Jennifer Keenahan 1, Réamonn Mac Réamoinn 1 1 Arup, 50 Ringsend Road, Dublin 4, Ireland email: cristina.paduano@arup.com,

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Page 1 of 5 Tudor House Tudor Industrial Estate Ashton Street Dukinfield Cheshire SK16 4RN Telephone: 0845 519 2116 Email: enquiries@worldheat.co.uk Web: www.worldheat.co.uk Reg. In England Number 6744323

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions 3500032/2 IM-P350-02 CH Issue 2 TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

PV4 and PV6 Piston Valves

PV4 and PV6 Piston Valves 1181250/1 IM-P118-05 ST Issue 1 PV4 and PV6 Piston Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6.

More information

MFP14-PPU (Vented) Automatic Packaged Pump Units

MFP14-PPU (Vented) Automatic Packaged Pump Units 681060/2 IM-P681-02 ST Issue 2 MFP14-PPU (ented) Automatic Packaged Pump Units Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Single MFP14 - PPU installation

More information

Paper #: POWER

Paper #: POWER Proceedings of POWER2008 ASME Power 2008 July 22-24, 2008, Orlando, Florida, USA Paper #: POWER2008-60061 THE USE OF AN EDDY CURRENT INSPECTION OF BRASS TUBES IN A SURFACE CONDENSER TO PROVIDE A CONDITION

More information

Vibration Related Failures of Small-Bore Attachments

Vibration Related Failures of Small-Bore Attachments Vibration Related Failures of Small-Bore Attachments Brian C. Howes, M.Sc., P.Eng Chief Engineer bhowes@betamachinery.com Chris B. Harper, P.Eng Project Engineer charper@betamachinery.com Beta Machinery

More information

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications 1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General

More information

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions 1870050/7 IM-P187-05 CMGT Issue 7 TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions TDC46M and TDS46M UTDS46M 1. Safety information 2.

More information

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group Pressure C. ASSEMBLIES Guideline C-03 Guideline related to: Article 4 paragraph 2 The effect of the derogation in Article 4 paragraph 2 from the introductory paragraph in the same article is not clear. In the circumstances,

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

SPECIFYING MOTIONLESS MIXERS

SPECIFYING MOTIONLESS MIXERS SPECIFYING MOTIONLESS MIXERS The operating cost for the energy necessary to mix fluids with a motionless mixer is usually far lower than for any competitive mixing technique. An extruder which melts, mixes

More information

Case study. Rotating Equipment Engineer Qatargas Operating Company. Sr. Rotating Equipment Engineer

Case study. Rotating Equipment Engineer Qatargas Operating Company. Sr. Rotating Equipment Engineer Case study Fluctuation of Seal Gas Supply Differential Pressure of Dry Gas Seals Rotating Equipment Engineer Qatargas Operating Company Sr. Rotating Equipment Engineer Qatargas Operating Company Outline

More information

S and SF Inverted Bucket Steam Traps

S and SF Inverted Bucket Steam Traps 0772150/6 IM-P077-02 ST Issue 6 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation

More information

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers 16355/11 IM-S6-17 ST Issue 11 Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating

More information

Experimental Study of Water Hammer Pressure in a Commercial Pipe

Experimental Study of Water Hammer Pressure in a Commercial Pipe IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) Experimental Study of Water Hammer Pressure in a Commercial Pipe Ashish Kumar Patel 1 1 (School of Mechanical Engineering, Lovely Professional

More information

CA44, CA44S, CA46 and CA46S Air and Gas Traps

CA44, CA44S, CA46 and CA46S Air and Gas Traps 1484450/3 IM-P148-37 ST Issue 3 CA44, CA44S, CA46 and CA46S Air and Gas Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

GAS SUPPLY APPLICATION GUIDE

GAS SUPPLY APPLICATION GUIDE GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers

More information

Digester Processes. 1. Raw Sludge Pumping System

Digester Processes. 1. Raw Sludge Pumping System Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters

More information

GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH ALL RIGHTS RESERVED -

GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH ALL RIGHTS RESERVED - GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH 2010 - ALL RIGHTS RESERVED - Part II page 2 of 10 ABSORBING SILENCER A any vent or blow-down application boiler

More information

TROUBLESHOOTING GUIDELINES

TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range

More information

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors 0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.

More information

TP1 and TP2 Temporary Cone Shaped Strainers

TP1 and TP2 Temporary Cone Shaped Strainers 1698051/2 IM-P169-07 ST Issue 2 TP1 and TP2 Temporary Cone Shaped Strainers Installation and Maintenance Instructions TP1 1. Safety information 2. General product information 3. Installation and commissioning

More information

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Dri-Line Mk3 Monnier Compressed Air Drain Trap 5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller CHEMICAL ENGINEERING LABORATORY CHEG 239W Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller Objective The experiment involves tuning a commercial process controller for temperature

More information

(Refer Slide Time: 2:16)

(Refer Slide Time: 2:16) Fluid Machines. Professor Sankar Kumar Som. Department Of Mechanical Engineering. Indian Institute Of Technology Kharagpur. Lecture-23. Diffuser and Cavitation. Good morning and welcome you all to this

More information

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving

More information

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps 1801050/10 IM-P180-05 ST Issue 10 BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3.

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats MAXI-SYSTEM DOC50/ Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats CW CW Maxi-System.9+ volt d.c. Maxi-System.9+ volt d.c. CW99A Maxi-System

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

Structure of Mechanically Agitated Gas-Liquid Contactors

Structure of Mechanically Agitated Gas-Liquid Contactors Structure of Mechanically Agitated Gas-Liquid Contactors 5 2 Structure of Mechanically Agitated Gas-Liquid Contactors 2.1 The vessel geometry The most commonly adopted geometry of a stirred gas-liquid

More information

FV Flash Vessel Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions 4041050/5 IM-P404-10 EMM Issue 5 FV Flash Vessel Installation and Maintenance Instructions 1. Safety information 2. Specific product safety information 3. Product information 4. Installation 5. Commissioning

More information

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers 16355/8 IM-S6-17 ST Issue 8 Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

SV60 Safety valves. for use with steam, gas and liquids

SV60 Safety valves. for use with steam, gas and liquids SV60 Safety valves for use with steam, gas and liquids Spirax Sarco safety valves - protecting people, plant and profit The SV60 spring loaded full lift safety valve range from Spirax Sarco has been designed

More information