Airfix Pressure expansion vessels for sanitary appliances and potable water systems
|
|
- Beverly Lamb
- 6 years ago
- Views:
Transcription
1 airfix expansion vessels Your reliable partner 4 Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E AIRFIX P Edition EXP 2009
2 Flamco offers you a wide choice in the field of The use of offers the user a number of important advantages. Airfix A and Airfix expansion vessels are through-flow vessels, meaning that they are specially constructed so that they regularly rinse themselves with fresh mains water. In this way, still, stagnant water, which is associated with the formation of detrimental bacteria, is eliminated from the equation. As a result, the quality of the potable water is preserved. As the interior of the vessel is coated there is no chance of the water coming into contact with untreated steel even in the event of damage to the internal diaphragm. Therefore, should the diaphragm become damaged the water will remain uncontaminated. By using the Airfix A and expansion vessels, you can also limit water wastage. AIRFIX A The Airfix A expansion vessel is supplied with a synthetic flow divider, suitable for T-pieces for pipes of max. 3 /4 (22 mm). This flow divider is placed in the standard T-piece (which is not included in the tank supply). The Airfix A expansion vessel and T-piece assembly must be fitted in the cold-water installation of the boiler and through-flow is established. USER AVANTAGES AIRFIX A AN AIRFIX u Very easy to fit. u Covered inside and out with an anti-corrosion coating, both in the water half and the nitrogen half. u Neither the diaphragm nor the coating give off any dye, smell or taste to the water; both have been approved by CE and the VGW (in Germany). u Can be used with any storage water heater. u Can also be used in pressure boosting systems. u Fitted with a butyl rubber membrane. Tables with types and technical information: page
3 expansion vessels for potable water installations Without an expansion vessel for sanitary appliances, the safety-valve (inlet combination) will leak water every time water is heated causing water wastage on each occasion. This significantly heightens the chance of lasting leakage as a result of pollution or calcium deposits building up in the area of the valve seat. This kind of serious water loss can now be stemmed by using an Airfix A or Airfix expansion vessel. AIRFIX All Airfix A and Airfix vessels are white in colour. Both butyl rubber diaphragm and vessel coating are internationally approved for use in combination with drinking water, meeting the CE standards (2002/16/EC). A reliable clamp construction which damages neither the vessel nor the diaphragm while allowing conservation of the entire vessel surface, something which is unthinkable in welded vessels without flanges. Airfix vessels use a special T-piece (supplied) which aids through-flow with its internal divider to ensure full through-flow in the vessel. An AirfixControl is fitted between the vessel and T-piece, enabling the Airfix vessel to be de-pressurized for maintenance work without the need for the installation to be put out of commission. The vessel pre-pressure must be 0.2 bar lower than the pressure behind the pressure-reducing valve in the cold water pipe in order to guarantee a proper flow. Internal coating prevents corrosion, even in case of a faulty membrane. irections on how to fit the Airfix pressure expansion vessel Airfix A or Airfix expansion vessels should always be used with a Prescor B boiler valve. The vessel must be mounted in the cold-water pipe, between the Prescor valve and boiler. Airfix A or with Prescor B boiler valve 4.3
4 Logical Airfix technology offers the user significant advantages The Airfix -E expansion tank can be used in pressure boosting systems, on either the intake or compression sides of the pumps. These installations are intended to prevent excessively low feeding pressure and help prevent excessive pressure changes at low flow speeds. At the same time, they reduce the number of times the pressure-water assembly needs to be switched. The Airfix -E expansion tank offers the precise solution for this. Airfix -E Pressure expansion tanks with exchangeable diaphragms, suitable for use in hot-water, pressure boosting and water-management systems. The Airfix -E is a solid, stable tank which is easy to fit. It is a through-flow tank with two flange connections which has an exchangeable butyl diaphragm. The high-quality material of which the diaphragm is constructed is your guarantee of low permeability (which means that your gas will not leak away) and if used correctly, renders permeability negligible. Airfix -E tanks are fitted standard with an electronic diaphragm-rupture sensor and an internally-coated steel through-flow flange. USER AVANTAGES AIRFIX -E u Very easy to fit. u Covered inside and out with an anti-corrosion coating, both in the water half and the nitrogen half. u Neither the diaphragm nor the coating give off any dye, smell or taste to the water; both have been approved by CE and the VGW (in Germany). u Can be used with any storage water heater. u Can also be used in pressure boosting systems. ON TE FLAMCO C you will find: This brochure as a PF file. Mounting instructions. WF files. CA symbols. Ensure that the double system connection is directly connected with the main flow in the potable water installation. Tables with types and technical information: page
5 AIRFIX -E AIRFIX -E-B AIRFIX -E-L Inspection port (from 600 litres above and below). Pressure gauge with self-sealing valve case and an Rp 3 /80 IN connection to the tank itself. iaphragm-rupture sensor, basic appliance, display with red LE indicating diaphragm rupture. Maximum permissible gas prepressure on delivery: 6 bars. Maximum working pressures 10 and 16 bar. Airfix -E tanks are coated green. iaphragm-rupture sensor including signal cable. The Airfix -E diaphragm expansion tank has a gas space between the tank wall and the exterior of the membrane, and a water space within the diaphragm. The configuration of the gas space depends on the operating characteristics and the required pressure. A pressure boost in the water space will compress the gas volume and fill the diaphragm, while a reduction in pressure will lead to draining of water. Should the pressure in the gas space reach the set water pressure in the installation, water will be drained from the connection pipe. In all operating conditions, water flows through the tank with a very low loss of pressure. See the pressure loss diagrams that are available as PF files on the C. Airfix -E-B For pressure boosting, potable household, processing or fire-extinguishing installations. Single steel threaded connection (without through-flow function) and without electronic membrane-rupture sensor. All materials used in this tank are potable water quality. Airfix -E ouble system connection the link with the connection pipe. Airfix -E-L ouble system connection with through-flow function. For use in hotwater, pressure boosting and watermanagement systems. 4.5
6 Airfix P: the series of expansion vessels for pressure boosting installations Airfix P expansion vessels are suitable for potable water, processing water and fire fighting water installations in the event that oxygen-rich water is used, and are available in contents between 2 litres and 5,000 litres, partially available in horizontal models. Airfix P tanks comply with the requirements of European Pressure Equipment irective 97/23/EC. AIRFIX P AIRFIX P AIRFIX P Male thread connection. Bladder made of butyl rubber. Steel tank in RAL System connection. The maximum operating pressure is 10 bar. Maximum continuous operating temperature at the bladder is 70 C. All tanks are fitted with an exchangeable bladder. The tank connection is not a flow-through type. Airfix P models 750 up to 5000 are fitted with a pressure gauge. AVANTAGES OF TE AIRFIX P: u Wide range of products suitable for many applications. u Available as both vertical and horizontal configurations. u as WRc and ACS approval. Tables with types and technical information: page
7 Airfix A and Airfix expansion vessels u As long as the flow divider is not used, the Airfix A expansion vessel will function as a non-through-flow vessel. u If the Airfix T piece is not used, the Airfix expansion vessel functions as a nonthrough-flow vessel. u The pressure expansion vessels, when used in boiler systems, must always meet the requirements of the water board. u The maximum temperature in Airfix vessels is 70 C. Versions and dimensions Airfix A Prepressure Capacity Max. operating pressure Connection (male thread) imensions in mm Weight in bar in litres in bar Ø A in kg Code number Airfix A / Airfix A / Airfix A / Airfix A / Airfix A / airfix a Versions and dimensions Airfix and AirfixControl Prepressure Capacity Max. operating pressure Connection (male thread) imensions in mm Weight Code number in bar in litres in bar Ø A in kg Airfix / Airfix / Airfix / Airfix / Airfix / AirfixControl A airfix Selection table for pressure expansion vessels if for boiler applications * ifferent pre-pressures available on request. Water contents boiler Cold water supply pressure in bar Set pressure Prescor B valve, Prescor inlet combination in litres 6,0 bar 7,0 bar 8,0 bar 10,0 bar Airfix 8/3 Airfix 8/3 Airfix 8/3 Airfix 8/ Airfix 12/4 Airfix 8/4 Airfix 8/4 Airfix 8/ Airfix 12/3 Airfix 12/3 Airfix 12/3 Airfix 8/ Airfix 18/4 Airfix 12/4 Airfix 12/4 Airfix 12/ Airfix 18/3 Airfix 12/3 Airfix 12/3 Airfix 12/ Airfix 25/4 Airfix 18/4 Airfix 18/4 Airfix 12/ Airfix 18/3 Airfix 18/3 Airfix 18/3 Airfix 12/ Airfix 25/4 Airfix 25/4 Airfix 18/4 Airfix 18/ Airfix 25/3 Airfix 18/3 Airfix 18/3 Airfix 18/ x Airfix 18/4 Airfix 25/4 Airfix 25/4 Airfix 18/4 A airfixcontrol 4.7
8 Airfix -E, -E-B and -E-L expansion tanks u Airfix -E and -E-B tanks from litres with a maximum operating pressure of 10 or 16 bars (-E-B also 25 bars) and a maximum temperature of 70 C. u Airfix -E-L tanks from litres with a maximum operating pressure of 10 bar. u Tanks with model approval in compliance with Council irective 97/23/EC. u iaphragm-rupture sensor, Council irective 89/336/EC-compliant. u Special execution (available on request) stainless steel through-flow flange (mat ) or a stainless steel mono-connection. If a mono-connection is fitted, the tank is no longer equipped with through-flow. Versions and dimensions Airfix -E Capacity in imensions in mm Flanges Weight in kg Code number litres Ø a e PN bar 16 bar 10 bar 16 bar Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N airfix d-e Versions and dimensions -E-B Capacity in imensions in mm Female-thread connection Weight in kg Code number litres Ø e ISO bar 16 bar 25 bar 10 bar 16 bar 25 bar Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G Airfix -E-B G Airfix -E-B G Airfix -E-B G 2 1 / Airfix -E-B G 2 1 / Airfix -E-B G 2 1 / a e airfix d-e-b Versions and dimensions Airfix -E-L Capacity in imensions in mm Female-thread connection Weight in kg Code number litres Ø e a ISO bar Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 2 1 / e airfix d-e-l Accessories Airfix -E Code number Remote reading diaphragm-rupture NOTE: When selecting the pre-pressure and after-pressure, please ensure that the maximum efficiency is not exceeded (60%). e 4.8
9 Loose connections for Airfix -E and Airfix -E-B expansion vessels Versions of mono connections For vessel content For vessel content Code number litres Mono small stainless steel G 1 1 / Mono medium stainless steel G Mono large stainless steel G 2 1 / Mono small coated G 1 1 / Mono medium coated G Mono large coated G 2 1 / Versions of duo connections For vessel content For vessel content Code number liter uo small stainless steel G 1 1 / uo medium stainless steel G uo large stainless steel G 2 1 /
10 Airfix P expansion vessels u For potable water, processing water and fire fighting water installations in cases where oxygen-rich water is used. u Fitted with a galvanized steel single thread connection (no flow-through function). u With WRc and ACS approval. u Standard pre-pressure of 2.7 bar. Versions and dimensions of the upright Airfix P expansion vessels Prepressure Capacity Max. operating pressure Connection (male thread) imensions in mm Weight in bar litres in bar Ø A in kg Code number Airfix P / Airfix P / Airfix P / Airfix P / Airfix P / Airfix P / Airfix P / Airfix P / Airfix P airfix P Airfix P Airfix P Airfix P Airfix P Airfix P Airfix P / Airfix P / A Airfix P / Airfix P / Airfix P Airfix P / Airfix P / Airfix P / Airfix P / Airfix P / Versions and dimensions of the horizontal Airfix P expansion vessels Prepressure Capacity Max. operating pressure Connection (male thread) imensions in mm Weight in bar litres in bar Ø A in kg Code number Airfix P / Airfix P Airfix P Airfix P Airfix P Airfix P Airfix P / Airfix P / Airfix P / A A airfix P horizontal 4.10
11 Your reliable partner worldwide u Flamco is renowned worldwide for its quality and service. It has 7 production facilities and 12 sales outlets under its own management. Reliable distributors represent Flamco in other countries. Australia Austria Belgium Cyprus Czech Republic enmark Estonia Finland France Germany Greece ungary Iceland Italy Japan Kuwait Latvia Lebanon Lithuania Netherlands New Zealand Norway Oman People s Republic of China Poland Portugal Qatar Romania Russia Saudi Arabia Slovakia South Africa Spain Sweden Switzerland Taiwan Turkey United Arab Emirates United Kingdom United States 4.11
12 AIRFIX A airfix expansion vessels TABLE OF CONTENTS page AIRFIX Airfix A and Airfix 4.2/4.3 Airfix -E, -E-B and -E-L 4.4/4.5 Airfix P 4.6 Tables 4.7/4.10 Flamco b.v. P.O. Box AC Gouda - olland Industriestraat AC Gouda - olland Telephone: (+ 31) Fax: (+ 31) info@flamco.nl AIRFIX -E On the Flamco C you will find all available information of the Flamco products. Copyright Flamco b.v., Gouda, olland. No part of this publication may be reproduced or published in any way without explicit mention of the source. The data listed are solely applicable to Flamco products. Flamco b.v. shall accept no liability whatsoever for incorrect use, application or interpretation of the technical information. Flamco b.v. reserves the right to make technical alterations. AIRFIX P Flamco b.v. refers you further to its international sales and delivery conditions as drawn up by Orgalime
Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E
AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice
More informationExpansion Vessels for Potable Installations
4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm
More informationMedium-sized vessels water connection. White paper
Medium-sized vessels water connection White paper Flamco B.V. January 2017 Medium-sized vessels water connection In practice you will find expansion vessels with the water connection on bottom, and with
More informationAirfix D-E-B Installation and operating instructions
www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel
More informationFlexcon. Flamco. Flamco. Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE FLEXCON M FLEXCON V-B FLEXCON EXPANSION VESSELS
FLEXCON EXPANSION VESSELS Flexcon Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE 110 1000 FLEXCON M FLEXCON V-B 2005 edition / EXP Choose quality choose a Flexcon the choice of a satisfied
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationAccessories for Sanitary Installations
5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the
More informationMax Sort Sortation Option - Letters
Max Sort Sortation Option - Letters Western Europe Prices Product Code PS5 PS6 Austria* 0.330 7.550 0.330 7.400 Belgium* 0.370 3.700 0.370 3.540 Denmark* 0.620 5.350 0.620 4.215 Finland* 0.385 4.400 0.385
More informationHydroCOM: High energy savings and excellent controllability
HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,
More informationDiaphragm Accumulators
1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.
More informationTHE WORLD COMPETITIVENESS SCOREBOARD 2011
THE WORLD COMPETITIVENESS SCOREBOARD 2011 98.557 94.063 92.588 92.011 90.782 90.219 89.259 87.824 86.475 86.418 86.313 85.707 84.380 84.120 81.629 81.619 81.100 80.278 79.799 78.499 77.599 77.101 76.827
More informationNITROGEN CHARGING KIT type PC 11.1 E 04-11
NITROGEN CHARGING KIT type PC 11.1 E 04-11 11.1.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 600 BAR PRESSURE TEST (PT): 1.43 PS SCALE OF PRESSURE GAUGE: 4-10 - 16-25 - 60-100 - 250 (std.) - 400-600 bar
More informationNITROGEN CHARGING KIT type PC 11.1 E 01-12
NITROGEN CHARGING KIT type PC 11.1 E 01-12 11.1.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 600 BAR PRESSURE TEST (PT): 1.43 PS SCALE OF PRESSURE GAUGE: 4-10 - 16-25 - 60-100 - 250 (std.) - 400-600 bar
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 15281 May 2006 ICS 13.230 English Version Guidance on Inerting for the Prevention of Explosions Atmosphères explosibles - Guide de l'inertage
More informationVESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure :
operating limits Temperature range : -10 to + C* Operating pressure : to 20 bar* * according to models. VESSES IAPHRAGM OR BAER TANKS For expansion and pressure boosting applications AdVANTAGES APPICATIONS
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationIntroductions, Middle East, Israel, Jordan, Yemen, Oman Week 1: Aug Sept. 1
Introductions, Middle East, Israel, Jordan, Yemen, Oman Week 1: Aug. 28 - Sept. 1 ASSIGNMENT Monday Tuesday Wednesday Thursday Friday Due Wednesday pgs. 6-11 Do not start the workbook or study sheet assignments
More informationAREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.
Reference series Composite leading indicators OECD Composite Leading Indicators AREA TOTALS 7-03- 19 OECD Total 19 OECD + Major 6 Non Member Countries 19 Major Seven 19 Major Five Asia 19 Euro area 19
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationJanuary Deadline Analysis: Domicile
January Deadline Analysis: Domicile Applicants by domicile at the 15 January deadline D.1.1 Applicants by domicile group UK EU (excluding UK) Not EU All domiciles 20% 10% -0% -10% -20% -30% -40% -50% 2009
More informationINDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS
IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate
More informationJune Deadline Analysis: Domicile
June Deadline Analysis: Domicile Applicants by domicile at the 30 June deadline I.1.1 Applicants by domicile group Difference between cycle and 2017 cycle UK EU (excluding UK) Not EU All domiciles 10%
More information24 November 2017, Nyon, Switzerland. 2017/18 UEFA European Women s Under-17 and Women s Under-19 Championships. Elite round draws
November 07, Nyon, Switzerland 07/8 UEFA European Women s Under-7 and Women s Under-9 Championships Elite round draws DRAW PROCEDURE Elite rounds th UEFA European Women s Under-7 and 7th UEFA Women s Under-9
More informationEuropean Values Study & World Values Study - Participating Countries ( )
GESIS Data Archive for the Social Sciences http://www.gesis.org/en/home/ ASEP/JD Data Archive http://www.jdsurvey.net/jds/jdsurvey.jsp European Values Study & World Values Study - Participating Countries
More informationAuxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003
Auxiliary Valve Pressure Reducing Valve June 2003 General Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue
More information2-port and 3-port seat valves, PN16
s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections
More informationSelection statistics
Selection statistics ERASMUS+ Sport Call for proposals EAC-A03-2016 Selection year 2017 Collaborative Partnerships Small Collaborative Partnerships Not-for-profit European Sport Events Erasmus+ Applications
More informationGas Pressure Regulator HON 502
Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas
More information3-port seat valves with externally threaded connection, PN 16
4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1
More informationFlamco. Flamco. Flamco. Accessories for heating systems PRESCOR PRESCOR S FLEXCON THERMO-PRESSURE GAUGE FLEXFAST FLEXCONSOLE
HETING SYSTEM ESSORIES ccessories for heating systems PRESOR PRESOR S FLEXON THERMO-PRESSURE GUGE FLEXFST FLEXONSOLE 2005 Edition / EXP complete programme for the protection of Prescor safety valves are
More informationFirearms & parts firearms & parts firearms & parts rocket launcher components
Table 3 Exports of Military Goods by Component Categories Export Period 01 January to 31 December 1997 Destination ECL Andorra 2001 5 434 2 058 Firearms & parts Argentina 2001 54 498 468 firearms & parts
More informationOECD employment rate increases to 68.4% in the third quarter of 2018
Paris, 17th January 2019 News Release: 3rd Quarter 2018 OECD employment rate increases to 68.4% in the third quarter of 2018 The OECD area employment rate the share of the working-age population with jobs
More informationSelection statistics
Selection statistics ERASMUS+ Sport Call for proposals EAC-A05-2017 Selection year 2018 Collaborative Partnerships Small Collaborative Partnerships Not-for-profit European Sport Events Applications received
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationPortuguese, English, and. Bulgarian, English, French, or
Country Language Fiber Content Algeria Arabic Angola Portuguese, English, and French (optional) Optional Argentina Spanish Armenia Armenian Optional Australia English Austria German Bahrain Arabic or English
More informationStudent Nationality Mix for BAT Bath
Student Nationality Mix for BAT Bath Country Total Saudi Arabia 16. Oman 11.8% Spain 10. China 10. Libya 7. Thailand 6. Korea (South) 6. France 3.9% Venezuela 3. Italy 2.9% Brazil 2. Turkey 2. Switzerland
More informationI. World trade in Overview
I. Table I.1 Growth in the volume of world merchandise exports and production by major product group, 1995-3 ( change) 1995-21 22 23 World merchandise exports 7. -.5 3. 4.5 Agricultural products 3.5 2.5
More informationNEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. July and August 2017
PRESS EMBARGO: NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 July and August 2017 Next press release: Tuesday 24 October 2017 1 Data for Malta unavailable Page 1 of 12 Commercial vehicle registrations:
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationHigh Precision Regulators R210 / R220 / R230 Series
High Precision Regulators R210 / R220 / R230 Series Catalogue no. PDE2542TCUK-ca WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationConfidence through experience. Track record as of 30 June 2012
Confidence through experience Track record as of 30 June 2012 Harvesting the full potential of wind Confidence is built through experience. During more than 30 years in the wind industry we have installed
More informationSealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide
1.25 Sealed Systems Sealed Systems Sealed primary central heating systems are the most commonly used form of heating system throughout Europe and the rest of the developed world. Sealed central heating
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationTwo-port valves, male threaded, PN25
4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...
More informationSTAUFF Accumulators Accessories
Local Solutions For Individual Customers Worldwide STUFF ccumulators Clamps & Supports 28 Safety Blocks 30 Burst Discs 34 Fuse Discs 35 Replacement Back-up Bottles 36 Clamps & Supports ccumulator Clamps
More informationUEFA Nations League 2018/19 League Phase Draw Procedure
Date and time: Wednesday, 24 January 2018 Place: Duration: Regulations: Participants: Objective: Seeding: Lausanne, Switzerland approx. 40 minutes for technical part Art. 12-13 of the competition regulations
More informationDifferential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting
Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.
More informationGlobal Construction Outlook: Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009
Global Construction Outlook: Short-term term Pain, Long-term Gain Laura Hanlon Product Manager, Global Construction Outlook May 21, 2009 What This Means for You The world is set to be hit this year with
More informationGCE CENTRAL GAS SYSTEMS THE DRINKS DISPENSE INDUSTRY EQUIPMENT FOR GAS SUPPLIER SYSTEMS
THE DRINKS DISPENSE INDUSTRY EQUIPMENT FOR GAS SUPPLIER SYSTEMS THE GCE BUSINESS GCE has almost 100 years of experience in the manufacture and supply of high pressure gas equipment. During this time the
More information2016/17 UEFA European Under-17 and Under-19 Championships Qualifying round draws. 3 December 2015, Nyon, Switzerland
2016/17 UEFA European Under-17 and Under-19 Championships Qualifying round draws 3 December 2015, Nyon, Switzerland DRAW PROCEDURE Qualifying rounds 16th UEFA European Under-17 and Under-19 Championships,
More informationHEXAGON RAGASCO A BETTER SHAPE FOR YOUR BUSINESS NIELS FREDERIKSEN, TECHNICAL SUPPORT MANAGER JAKARTA, INDONESIA,
HEXAGON RAGASCO A BETTER SHAPE FOR YOUR BUSINESS NIELS FREDERIKSEN, TECHNICAL SUPPORT MANAGER JAKARTA, INDONESIA, 03-12-2014 NIELS FREDERIKSEN NIELS FREDERIKSEN Joined Hexagon Ragasco in 2013. 25+ years
More informationValue Exported (CDN$) Support Systems ,165 firearms ,389 firearms ,465 firearms ,500 rocket launchers
Table 3 Exports of Military Goods by Component Categories Export Period 01 January to 31 December 1998 Value Exported (CDN$) Andorra Argentina Australia Austria Bahrain 2001 2,165 firearms 2001 137,389
More informationDesalination From theory to practice People, Papers, Publications. Miriam Balaban EDS Secretary General
Desalination From theory to practice People, Papers, Publications Gulf WSTA Europe EDS Miriam Balaban EDS Secretary General Europe and the Gulf Region The collaboration between our regions has had significant
More informationASB Accumulator Safety Blocks
ASB Accumulator Safety Blocks For working pressures up to 350 bar Catalogue HY07-1241/UK Note: In line with our policy of continuing product improvement, specifications in this catalogue are subject to
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More information2015/16 UEFA European Women s Under-17 and Women s Under-19 Championships Elite round draws
2015/16 UEFA European Women s Under-17 and Women s Under-19 Championships Elite round draws 13 November 2015, Nyon, Switzerland DRAW PROCEDURE Elite rounds UEFA European Women s Under-17 and Women s Under-19
More information23 November 2018, Nyon, Switzerland. 2019/20 UEFA European Women s Under-17 and Women s Under-19 Championships. Qualifying round draws
23 November 208, Nyon, Switzerland 209/20 UEFA European Women s Under-7 and Women s Under-9 Championships Qualifying round draws DRAW PROCEDURE Qualifying rounds 3th UEFA European Women s Under-7 and 9th
More informationUpgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software
Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software For technical support, call your local Bio-Rad office, or in the US, call 1-800-424-6723. Bio-Rad Laboratories, Inc.,
More informationKINGDOM OF CAMBODIA NATION RELIGION KING 3
KINGDOM OF CAMBODIA NATION RELIGION KING 3 TOURISM STATISTICS REPORT February 2018 MINISTRY OF TOURISM Statistics and Tourism Information Department No. A3, Street 169, Sangkat Veal Vong, Khan 7 Makara,
More information2016/17 UEFA European Women s Under 17 and Women s Under 19 Championships Qualifying draws
2016/17 UEFA European Women s Under 17 and Women s Under 19 Championships Qualifying draws 13 November 2015, Nyon, Switzerland DRAW PROCEDURE Qualifying rounds UEFA European Women s Under-17 and Women
More informationGRUNDFOS DATA BOOKLET. GT tanks. For cold-water and heating applications
GRUNFOS ATA BOOKLET For cold-water and heating applications ontents General data Applications 3 Type key 3 Tank range 3 Overview of tank types 3 Approvals and markings 3 Tank colours 3 Operating conditions
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing
More informationICS Will supersede EN :1997. English Version
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM DRAFT pren 1176-7 January 2006 ICS Will supersede EN 1176-7:1997 English Version Playground equipment and surfacing - Part 7: Guidance on installation,
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationTable 34 Production of heat by type Terajoules
Table 34 Production of heat by type Table Notes geo represents heat used directly for district heating, agriculture etc. without a commercial transaction taking place. represents heat used for the production
More informationMasoneilan* 78 Model Air Filter Regulator
GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE
More informationMasoneilan* Model 78-80H & 08-80H Transfer Valves
GE Oil & Gas Masoneilan* Model 78-80H & 08-80H Transfer Valves Instruction Manual GE Data Classification: Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE
More informationGrundfos GT TANK Keep it safe
GRUNDFOS GT TANK Grundfos GT TANK Keep it safe Long-life tanks for all needs Grundfos pressure tanks are all ideally suited and approved for use with drinking water. The material used ensures that there
More informationILNAS-EN :2005
Respiratory protective devices - Compressed air line breathing apparatus with demand valve - Part 2: Apparatus with a half mask at positive pressure - Requirements, testing, marking Atemschutzgeräte -
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationInstallation, Operation and Maintenance Instructions Buffer Vessel OM006
Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More information2014/15 UEFA European Under-17 and Under-19 Championships Elite round draws. 3 December 2014, Nyon, Switzerland
0/5 UEFA European Under-7 and Under-9 Championships Elite round draws December 0, Nyon, Switzerland DRAW PROCEDURE Elite rounds th UEFA European Under-7 and Under-9 Championships, 0/5 TEAMS QUALIFYING
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More informationStockholm s tourism industry. November 2016
Stockholm s tourism dustry. November 2016 Durg the month of November ca 1.1 million guest were recorded at commercial accommodations the county of Stockholm. This was an crease of 5 compared to November
More informationWorkshop Compressors CLASSIC Series
www.hpccompressors.co.uk Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only
More informationPressure regulator for water
Pressure regulator for water rass version with VGW and international drinking water approvals Stainless steel version with VGW approval Compact plastic version Manometer port at pressure output The water
More informationRemote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004
Remote Control Pneumatic Proportional Remote Control Valve zrc02 Catalogue HY17-8356/UK December, 2004 Catalogue Information Catalogue layout This catalogue has been designed to give a brief overview of
More informationMeasurement accessories METPOINT OCV for the measurement in systems up to 40 bar
EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationSafety shut-off valve S 100. Product information
Safety shut-off valve S 100 Product information 03.2017 Subject to modifications! Reprint prohibited! Table of Contents Application, Characteristics, Technical Data 4 Application 4 Characteristics 4 Type
More informationAVP-F. p setting range (bar) Code No. 003H6200
Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator
More informationStockholm s tourism industry. December 2016
Stockholm s tourism dustry. December 2016 Durg the month of December ca 0.9 million guest were recorded at commercial accommodations the county of Stockholm. This was an crease of 12 compared to December
More informationMainsboost Installation, Operation & Maintenance Instructions
mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information
More informationGE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public
GE Oil & Gas 77-6 Model Masoneilan* Air Lock-up Valve Instruction Manual GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION
More informationTABLE 1: NET OFFICIAL DEVELOPMENT ASSISTANCE FROM DAC AND OTHER DONORS IN 2012 Preliminary data for 2012
TABLE 1: NET OFFICIAL DEVELOPMENT ASSISTANCE FROM DAC AND OTHER DONORS IN 2012 DAC countries: 2012 2011 2012 ODA ODA/GNI ODA ODA/GNI ODA Percent change USD million % USD million % USD million (1) 2011
More informationDemography Series: China
Demography Series: China April 9, 212 Dr. Edward Yardeni 16-972-7683 eyardeni@ Sailesh S Radha 83-786-1368 sradha@ Please visit our sites at www. blog. thinking outside the box Table Of Contents Table
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More informationAir Reservoirs. 1st edition. This publication is not subject to any update service. New versions are available in INFORM at
1st edition This publication is not subject to any update service. New versions are available in INFORM at www.wabco-auto.com 815 000 490 3 8150004903 c Copyright WABCO 2005 Vehicle Control Systems An
More information94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?
94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank
More informationGas Pressure Regulator R 51
Gas Pressure Regulator R 51 Product Information Subject to technical modifications! Reprint prohibited! Table of Contents Application, Features, Technical Data 4 Application 4 Features 4 Type of model
More informationOperating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001
Operating Instructions Charging & Gauging Kit Effective: 01 July 2001 For use with Piston, Bladder & Diaphragm Accumulators Warning FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More information