Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

Size: px
Start display at page:

Download "Endotracheal Tubes - VentiSeal (High Volume Low Pressure)"

Transcription

1 Endotracheal Tubes - VentiSeal (High Volume Low Pressure) VentiSeal reduces the risk of vocal cord injury and tracheal necrosis through an optimal volume cuff with ideal pressure distribution and effective sealing. The thin ultra-smooth cuff wall reduces abrasive creases and folds, conforms to the tracheal contours and provides an effective seal. The diagram demonstrates the difference between the surface area that is in contact with the trachea when using a VentiSeal Cuffed Tube and a conventional cuffed tube. The cuff shape and length of the VentiSeal Endotracheal Tube enables the pressure to be distributed over a larger surface area, minimising the pressure placed on the tracheal wall and reducing the risk of tracheal wall necrosis. VentiSeal Conventional Kink Resistant Ensures tube patency for patient safety, whilst softening at body temperature to conform to the patient s respiratory tract. Depth Guide The double line guide facilitates safe and accurate cuff placement below the vocal cords. Pilot Balloon In addition to providing a tactile check on cuff inflation, the pilot balloon clearly identifies the tube size. SIZE ID (mm) ORAL/NASAL CURVED (Oral) SOUTH CURVED (Oral) NORTH CURVED (Nasal) NORTH REINFORCED WITH STYLET PACK SIZE

2 Endotracheal Tubes - Standard (Low Pressure Cuff) The Standard range of Low Pressure Endotracheal Tubes are designed for short-term intubation. The cuff size and shape make the them ideal for emergency situations, as the slim-line shape facilitates quick and easy intubation to maintain an open airway. Kink Resistant Ensures tube patency for patient safety, whilst softening at body temperature to conform to the patient s respiratory tract. Depth Guide The double line guide facilitates safe and accurate cuff placement below the vocal cords. Pilot Balloon In addition to providing a tactile check on cuff inflation, the pilot balloon clearly identifies the tube size. High Resolution Radiopaque Line Guarantees easy and accurate identification of tube position and location during X-ray. SIZE ID (mm) ORAL/NASAL CURVED (Oral) CURVED (Nasal) PACK SIZE ET Tube Holder Securely retains the position of all sizes of ET Tube. Jaw Opener To be used with an ET Tube when the patient has Teeth Clench. ET Tube & Tracheostomy Straps Eliminates the need for taping and distributes pressure evenly ET Tube Holder Jaw Opener ET Tube Straps Tracheostomy Straps 10 AIRWAY MANAGEMENT 23

3 Endotracheal Tubes - Plain Tubes (without cuff) Our comprehensive range of Plain Endotracheal Tubes have unique features to ensure patients safety and comfort, allowing intubation with total confidence. Clear Positioning Guides The 2.0 to 5.0mm ID tubes feature a Depth Guide to identify correct placement beyond the vocal cords and an orientation guide to indicate the position of the Murphy s Eye and tube tip. Distance Markers start at 3cms for safe and accurate placement in the smallest patients. Smooth Bevelled Tip Rounded bevelled tip reduces risk of damage to vocal cords during intubation. High Resolution Radiopaque Line Guarantees easy and accurate identification of tube position and location during x-ray. Kink Resistant Ensures tube patency for patient safety, whilst softening at body temperature to conform to the patient s respiratory tract. Depth Guide For accurate placement below the vocal cords, the Plain Endotracheal Tubes sized 5.5mm ID and above (Adult) feature the same double line depth guide as Flexicare s Standard Endotracheal and VentiSeal Tubes. SIZE ID (mm) ORAL/NASAL PREFORMED ORAL PREFORMED NASAL REINFORCED WITH STYLET PACK SIZE

4 Bougies and Stylets Flexicare's single use Bougies and Stylets complement the range of Laryngoscopes and Endotracheal Tubes, providing clinicians with a comprehensive choice of airway management devices. Bougies Reduced Patient Trauma The rounded tip provides a smooth surface that allows the Bougie to be inserted without damaging the soft tissue. Coude Tip Facilitates correct placement by providing accurate feel of the tracheal wall C-Rings. The flexibility also allows for easy removal once an ET Tube is in situ. Clearly Graduated Marking Provides depth indication to guide correct placement. Eliminate the Risk of Cross Contamination Provided sterile, the single patient use Bougie eliminates the risk of cross-infection Bougie / Introducer OD 3.3mm (10CH) x 700mm Sterile Bougie / Introducer OD 5.0mm (15CH) x 700mm Sterile 10 Stylets The malleable stylets have an aluminium core and a soft touch outer casing in a range of outer diameters and lengths to meet specific patient needs. Range of Flexibility The stylets can be shaped into the required curvature to suit the intubation need. Smooth Tip Reduces the risk of damaging soft tissue. Single Patient Use Supplied sterile, eliminating the risk of cross-contamination. OD CH LENGTH USE Stylet (Sterile) 2.2mm 6 225mm Paediatric Stylet - Long (Sterile) 4.0mm mm Adult Stylet - Long (Sterile) 5.0mm mm Adult Stylet - Extra Long (Sterile) 4.0mm mm Adult Stylet - Extra Long (Sterile) 5.0mm mm Adult 10 AIRWAY MANAGEMENT 25

5 Nasopharyngeal Airways NasoSafe is an innovative Nasopharyngeal Airway. The swivel safety grip eliminates the risk of the airway from being drawn down the nasal passage whilst providing maximum comfort for the patient. Patient Comfort The safety grip can be rotated through 360 to place the airway in the most convenient and comfortable position without blocking the free nostril. Allows Access NasoSafe is ideal when the oral passage is not accessible and allows for nasotracheal suctioning. Reduced Risk of Injury The rounded edge of the tip combined with the angle cut design helps reduce the risk of injury during intubation. Size Colour Coding Available in 11 sizes with colour coded swivel grips, that co-ordinate with suction catheter sizes. Swivel Safety Grip The NasoSafe swivel grip prevents the nasopharyngeal airway from being drawn into the nasal passage without the need for an additional fixation device, such as a safety pin. Better Tolerance NasoSafe is better tolerated by awake patients than oropharyngeal airways. NasoSafe is best inserted when the patient is in the supine position. The airway should be lubricated with a water soluble lubricant prior to insertion. The rounded bevelled tip reduces mucosal wall trauma and guides the airway along the floor of the nasal passage. When correctly in place the tip of the airway should be visible behind the uvula. mm fr ID OD NasoSafe Size 4 - Dark Green 4.0mm 20fr NasoSafe Size Dark Green 4.5mm 22fr NasoSafe Size 5 - Black 5.0mm 24fr NasoSafe Size Black 5.5mm 26fr NasoSafe Size 6 - Green 6.0mm 28fr NasoSafe Size Green 6.5mm 28fr NasoSafe Size 7 - Orange 7.0mm 30fr NasoSafe Size Orange 7.5mm 32fr NasoSafe Size 8 - Dark Red 8.0mm 34fr NasoSafe Size Dark Red 8.5mm 36fr NasoSafe Size 9 - Purple 9.0mm 38fr 10 26

6 Nasopharyngeal Airways NasoClear is a simple and effective airway adjunct designed for easy insertion and maximum patient compliance. In-Built Safety NasoClear has an integrated connector designed to prevent the tube from travelling down the nasal passage and removes the need to use a safety pin, eliminating the risk of needle stick injury. Clear Construction Provides visual confirmation before insertion that there are no blockages. Reduced Risk of Injury Rounded bevelled tip reduces mucosal wall trauma and guides the airway along the floor of the nasal passage. Patient Comfort NasoClear is better tolerated by awake patients than oropharyngeal airways. Flared Nasal Opening The large flared opening prevents the nasopharyngeal airway from physically travelling down the nasal passage and allows for comfortable positioning without obstructing the other nostril. Patient Fit Available in 11 sizes for optimal patient fit. Nasoharyngeal Airway Insertion Technique The length of the nasal airway can be estimated by the distance from the patient s nostril to the earlobe, or the angle of the jaw. The nasal airway is best inserted when the patient is in the supine position. Lubricate the airway prior to insertion with a water soluble lubricant C NasoClear Size 4 4.0mm 20fr C NasoClear Size mm 22fr C NasoClear Size 5 5.0mm 24fr C NasoClear Size mm 26fr C NasoClear Size 6 6.0mm 28fr C NasoClear Size mm 28fr C NasoClear Size 7 7.0mm 30fr C NasoClear Size mm 32fr C NasoClear Size 8 8.0mm 34fr C NasoClear Size mm 36fr C NasoClear Size 9 9.0mm 38fr 10 mm ID Insert with the curve facing the opposing direction and follow the nasal passage whilst turning the nasopharyngeal airway through 180 o fr OD AIRWAY MANAGEMENT 27

7 Airways Guedel Airways Guedel Airways provide free air flow whilst protecting the airway from occlusion. Williams Airways Opening on the distal half of the lingual surface, provides a conduit for fibre-optic guided intubation. Colour Coded Easy identification of the required size. Integrated Bite Block Prevents the patient from biting down and occluding airway. Smooth bevelled tip Allows for easy insertion and minimising the risk of causing patient trauma. Sterile Individually packaged and single use. Supplied sterile to reduce risk of crossinfection. Embossed Size Device size is embossed on airway providing easy identification of size even if the user is unfamiliar with colour coding. GUEDEL LENGTH (cm) SIZE COLOUR WILLIAMS LENGTH (cm) COLOUR Berman Oropharyngeal Airways Side channels enable the use of suction catheters without obstructing the airway, whilst allowing for additional air flow. BERMAN LENGTH (cm) SIZE Guedel Airways applicable standard BS EN ISO 5364:2011

IDEAL FOR SHORT- TO MEDIUM- TERM ANAESTHESIA OR VENTILATION. Anaesthesia Tracheal Tubes

IDEAL FOR SHORT- TO MEDIUM- TERM ANAESTHESIA OR VENTILATION. Anaesthesia Tracheal Tubes IDEAL FOR SHORT- TO MEDIUM- TERM ANAESTHESIA OR VENTILATION Anaesthesia Tracheal Tubes Common Features Clear tube material Allows visualisation of condensed exhaled air indicating tracheal intubation.

More information

SAFE SOLUTIONS TO THE PROBLEMS OF SPECIALITY ANAESTHETIC AND SURGICAL PROCEDURES. Speciality Anaesthesia Tubes

SAFE SOLUTIONS TO THE PROBLEMS OF SPECIALITY ANAESTHETIC AND SURGICAL PROCEDURES. Speciality Anaesthesia Tubes SAFE SOLUTIONS TO THE PROBLEMS OF SPECIALITY ANAESTHETIC AND SURGICAL PROCEDURES Speciality Anaesthesia Tubes Common Features Clear tube material Allows visualisation of condensed exhaled air indicating

More information

throat/pharyngeal pack

throat/pharyngeal pack DESCRIPTION IFU for Pat Tube endotracheal tube with integrated throat/pharyngeal pack The PAT Tube is supplied sterile with standard 15 mm connectors. The pharyngeal pack can be positioned above the laryngeal

More information

RESPIRATORY HEALTH PRODUCTS

RESPIRATORY HEALTH PRODUCTS RESPIRATORY HEALTH PRODUCTS CONTENTS ADULT ENDOTRACHEAL TUBES HALYARD* MICROCUFF* ENDOTRACHEAL TUBES Oral/Nasal Magill page 4 HALYARD* MICROCUFF* SUBGLOTTIC SECRETION DRAINAGE ENDOTRACHEAL TUBE Subglottic

More information

LarySeal - Laryngeal Mask Airways

LarySeal - Laryngeal Mask Airways LarySeal - Laryngeal Mask Airways The LarySeal range of Laryngeal Mask Airways have the following common benefits, which are incorporated into the Clear, Blue, Multiple, MRI and Flexi. Reduced risk of

More information

Great products available through ROI!

Great products available through ROI! Great products available through ROI! AGREEMENT NUMBER Through May 31, 2019 DISP. FIBER OPTIC LARYNGOSCOPES Blades and handles completely disposable Blades constructed of surgical stainless steel, and

More information

(3) isolates the airway preventing aspiration; (4) prevents gastric insufflation during positive

(3) isolates the airway preventing aspiration; (4) prevents gastric insufflation during positive I. Subject: Endotracheal Intubation II. Policy: Respiratory Therapists certified in endotracheal intubation will intubate in cases of emergency including: A. Respiratory arrest B. Overt respiratory failure

More information

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama Airways and Resuscitators CRC 330 Cardiorespiratory Care University of South Alabama Causes of Upper Airway Obstruction CNS depressionanesthesia, drug overdose Cardiac arrest Loss of consciousness Foreign

More information

Caring for our most delicate patients

Caring for our most delicate patients Caring for our most delicate patients Neonatal Catalogue ITU BREATHING SYSTEMS OXYGEN & AEROSOL THERAPY ANAESTHESIA LARYNGOSCOPES ENDOTRACHEAL TUBES RESUSCITATION Introduction to Flexicare Managing Director,

More information

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

VividTrac R. Video Intubation Device.  INSTRUCTIONS FOR USE. English VividTrac R Video Intubation Device INSTRUCTIONS FOR USE English www.vividmed.com Manufactured in the USA by: Vivid Medical, Inc. 1023 Corporation Way Palo Alto, CA. 94303, U.S.A. Phone 650-618-5725 www.vividmed.com

More information

Solutions for Oxygen Therapy & Airway Management

Solutions for Oxygen Therapy & Airway Management Solutions for Oxygen Therapy & Airway Management Designed to ensure optimal performance, safety and patient comfort Thermo Fisher Scientifi c is pleased to provide Healthcare Professionals with our comprehensive

More information

PRODUCT CATALOGUE OF

PRODUCT CATALOGUE OF PRODUCT CATALOGUE OF INTERVENTIONAL CARDIOLOGY AND GENERAL MEDICAL DISPOSABLES Table of Contents INFLATION DEVICE... 4 GUIDE WIRE (PTFE)... 5 MANIFOLD... 6 PTCA Y Connector... 7 INTRODUCER SHEATH (Femoral/

More information

SPEMS SKILLS PROFICIENCY CRITERIA Paramedic

SPEMS SKILLS PROFICIENCY CRITERIA Paramedic SPEMS SKILLS PROFICIENCY CRITERIA Paramedic The following skills are required at the Paramedic Level: 1. King Airway 2. IV 3. Endotracheal Intubation 4. Adult EZ IO 5. Pedi EZ IO 6. Pleural Decompression

More information

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System PneuX P.Y. Endotracheal Tube Designed exclusively for use with the Venner PneuX P.Y. System CONTENTS 1 Device description 01 2 Features 01 3 Warning and Cautions 01 4 Precautions 02 5 Adverse reactions

More information

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System

PneuX P.Y. Endotracheal Tube. Designed exclusively for use with the Venner PneuX P.Y. System PneuX P.Y. Endotracheal Tube Designed exclusively for use with the Venner PneuX P.Y. System CONTENTS 1 Device description 01 2 Features 01 3 Warning and Cautions 01 4 Precautions 02 5 Adverse reactions

More information

RESPIRATORY HEALTH PRODUCTS

RESPIRATORY HEALTH PRODUCTS RESPIRATORY HEALTH PRODUCTS CONTENTS ADULT CLOSED SUCTION SYSTEMS HALYARD* CLOSED SUCTION SYSTEMS Double Swivel Elbows page 54 WET PAK* Double Swivel Elbows page 54 T-Pieces page 65 WET PAK* T-Pieces page

More information

Day-to-day management of Tracheostomies & Laryngectomies

Day-to-day management of Tracheostomies & Laryngectomies Suctioning Suctioning the airway is an essential part of routine care of the tracheostomy and laryngectomy patient. Sputum is continually produced in health and our native airways deal with this load without

More information

Emergency Products Difficult Airway

Emergency Products Difficult Airway Emergency Products Difficult Airway VBM Medizintechnik GmbH VBM 1 Summary Laryngeal Tube... 4-5 Cricothyrotomy-Set Quicktrach... 6 Jet Ventilation... 7 Tube Exchanger and Introducer... 8 Endoscopy Mask

More information

Product Catalog

Product Catalog Product Catalog Ventlab Ethox Airway Management Resuscitation/Ventilation Anesthesia Respiratory Emergency Oxygen Delivery Diagnostics Surgical www.sun-med.com 800-433-2797 SURGICAL Welcome! Core Values

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 5366 First edition 2016-10-01 Anaesthetic and respiratory equipment Tracheostomy tubes and connectors Matériel d anesthésie et de réanimation respiratoire Raccords et tubes de

More information

Anesthesia Products & Circuits

Anesthesia Products & Circuits Anesthesia Products & Circuits Anesthesia Products & Circuits The world of anesthesia is the mysterious interplay of machinery, medicine and humanity, and the suspension of consciousness that allows the

More information

HOSPITAL: Date: Date: Date: Date:

HOSPITAL: Date: Date: Date: Date: HOSPITAL: Respiratory Care Services Policy and Procedure Manual Policy and Procedure Area: Respiratory Care Services Policy Number: Current Effective Date Review Date Revised Date StabilTube Performed

More information

Summary Report for Individual Task Perform Oral Suctioning Status: Approved

Summary Report for Individual Task Perform Oral Suctioning Status: Approved Report Date: 27 Jun 2012 Summary Report for Individual Task 081-833-0099 Perform Oral Suctioning Status: Approved DISTRIBUTION RESTRICTION: Approved for public release; distribution is unlimited. DESTRUCTION

More information

AT Kelly Torso. Directions for Use

AT Kelly Torso. Directions for Use AT Kelly Torso Directions for Use Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway Management

More information

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula Chapter 12 Respiratory Procedures Procedure 81 Checking Capillary Refill Procedure 82 Using A Pulse Oximeter Procedure 83 Preparing Wall-Outlet Oxygen Procedure 84 Preparing The Oxygen Cylinder Procedure

More information

PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT

PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT This Practice Guideline sets out the minimum recommended equipment for an Emergency Centre. It should be read in conjunction with Practice Guideline

More information

Ambu Aura40. Key Benefits

Ambu Aura40. Key Benefits Ambu Aura40 Key Benefits Built-in anatomically correct curve for fast and easy insertion Reinforced tip resists folding over during insertion and plugs the upper esophageal sphincter Cuff and airway tube

More information

Venner PneuX ETT/TT INSTRUCTIONS FOR USE

Venner PneuX ETT/TT INSTRUCTIONS FOR USE Venner PneuX ETT/TT EN (UK) INSTRUCTIONS FOR USE Manufactured for: Venner Medical (Singapore) Pte Ltd 35 Joo Koon Circle, Singapore 629110 www.vennermedical.com EU Authorised Representative: Advena Ltd

More information

Using the laryngeal mask airway to manage the difficult airway

Using the laryngeal mask airway to manage the difficult airway Anesthesiology Clin N Am 20 (2002) 863 870 Using the laryngeal mask airway to manage the difficult airway Martin S. Bogetz, MD Department of Anesthesia and Perioperative Care, University of California

More information

Anesthesia Intensive Care

Anesthesia Intensive Care Anesthesia Intensive Care VBM Medizintechnik GmbH VBM 1 Summary Manujet III, Jet Ventilation Catheters... Cricothyrotomy Sets Quicktrach, Cricothyrotomy Trainer... Tube Exchangers and Introducers... Laryngeal

More information

TUBINGS / CONNECTION PIECES

TUBINGS / CONNECTION PIECES SILICONE TUBINGS, smooth autoclavable, Color: transparent O.D. I.D. I.D. x C O.D. REF Box (mm) (mm) 0.5 x 0.4 1.3 68-005-04 25 m 1.0 x 0.5 2.0 68-010-05 25 m 1.0 x 1.0 3.0 68-010-10 25 m 1,5 x 0.75 3.0

More information

Fields of Excellence. Ambu. Ambu 75 years past, present and future. Ambu's commitment to quality. Anaesthesia. Emergency Care

Fields of Excellence. Ambu. Ambu 75 years past, present and future. Ambu's commitment to quality. Anaesthesia. Emergency Care Ambu Airway Ambu Fields of Excellence Ambu's company philosophy has always been the desire to make life easier for doctors and to find innovative products that can save lives. Innovation and entrepreneurship

More information

Assessment & Placement GUIDE

Assessment & Placement GUIDE Assessment & Placement GUIDE Quick Tips for Application of the Passy Muir Valve All Passy Muir Valves Have the patented closed position no-leak design, which means the valve is always closed until the

More information

AT Kelly Torso. Directions for Use

AT Kelly Torso. Directions for Use AT Kelly Torso Directions for Use 260-00001 2 Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway

More information

Emergency Products Difficult Airway

Emergency Products Difficult Airway Emergency Products Difficult Airway VBM Medizintechnik GmbH VBM 1 Summary Laryngeal Tubes... Cricothyrotomy-Sets Quicktrach... Jet Ventilation... Tube Exchangers and Introducers... Endoscopy Mask and Accessories...

More information

INSTRUCTIONS FOR USE KING LT 2

INSTRUCTIONS FOR USE KING LT 2 2 Caution: Federal law restricts this device to sale by or on the order of a physician. Instructions for Use In order to use the safely, the user must first be familiar with the following instructions,

More information

Product Catalogue. Emergency Medicine

Product Catalogue. Emergency Medicine VBM Product Catalogue Emergency Medicine Table of Contents Laryngeal Tube Laryngeal Tube Laryngeal Tube LTS-D 4 intubating Laryngeal Tube ilts-d 5 Cuff Pressure Gauges Cuff Pressure Gauges Cuff Manometer

More information

Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic

Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic New Hampshire Division of Fire Standards & Training and Emergency Medical Services Introduction The LMA was invented

More information

INSTRUCTION MANUAL S SIMON AIRWAY TRAINER. Gaumard Scientific Company, Inc SW 136 Street Miami, FL

INSTRUCTION MANUAL S SIMON AIRWAY TRAINER. Gaumard Scientific Company, Inc SW 136 Street Miami, FL INSTRUCTION MANUAL S315.100 SIMON AIRWAY TRAINER Gaumard Scientific Company, Inc. 14700 SW 136 Street Miami, FL 33196-5691 email: sima@gaumard.com 2005 Gaumard Scientific All Rights Reserved Revised: August

More information

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm 1 Chapter 9 Airway 2 Respirations Every cell of the body requires to survive Oxygen must come in and carbon must go out 3 Metabolism Metabolism--Process where the body s cells convert food to Adequate

More information

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego Fiberoptic Intubation Made Easi(er) Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego Know Your Scope Check before use: if it won t work during check out, it won t work during intubation

More information

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia ANAPOD TM Heated Humidification System for Anesthesia The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature Improve Patient Comfort Minimize PONV Westmed_Anapod_prod_sht_133941.9.indd

More information

SECTION 2. Advanced Airway Management

SECTION 2. Advanced Airway Management CAMPMS02_0131194372.qxd 7/20/05 9:52 PM Page 161 SECTION 2 Advanced Airway Management Fabulous Factoids Skill Sheets Bag-Valve-Mask Ventilation Adult Ventilatory Management Endotracheal Intubation with

More information

Emergency Products Difficult Airway

Emergency Products Difficult Airway Emergency Products Difficult Airway VBM Medizintechnik GmbH VBM 1 VBM 2 Summary Laryngeal Tubes... Cricothyrotomy-Sets Quicktrach... Jet Ventilation... Stylets, Tube Exchangers and Introducers... Laryngobloc...

More information

Laryngectomy Tubes. Severn Healthcare technologies are proud to introduce new solutions for Laryngectomy care from Fahl.

Laryngectomy Tubes. Severn Healthcare technologies are proud to introduce new solutions for Laryngectomy care from Fahl. Laryngectomy Tubes Severn Healthcare technologies are proud to introduce new solutions for Laryngectomy care from Fahl. The LARYNGOTEC laryngectomy tubes, made of soft, flexible silicone, are designed

More information

Canine Endotracheal Intubation

Canine Endotracheal Intubation Canine Endotracheal Intubation Year Group: BVSc3 + Document Number:CSL_A05 Equipment list: Equipment for this station: Soft dog model Laryngoscope with appropriate size head Appropriate size of endotracheal

More information

Sterile product catalogue

Sterile product catalogue Sterile product catalogue S Respiratory products and systems Quality, innovation and choice product catalogue sterile product range For over twenty five years Intersurgical has been supplying a wide range

More information

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE TITLE: ISSUED FOR: ENDO TRACHEAL SUCTIONING OF THE ADULT PATIENT (suc03) Nursing, Respiratory DATE: REVIEWED: PAGES: 11/82 12/18 1 of 5 RESPONSIBILITY: RN,

More information

Pediatric. VBM Medizintechnik GmbH. Products VBM 1

Pediatric. VBM Medizintechnik GmbH. Products VBM 1 Pediatric Products VBM Medizintechnik GmbH VBM 1 Treatment of children, especially of newborns, requires the highest level of medical care. VBM fulfils these requirements and produces almost all products

More information

General Anaethesia Airway

General Anaethesia Airway General Anaethesia Airway Breathing Systems Catalogue Breathing Circuits Face Masks Circuit Accessories Contents I Expandable Length Dual-Limb Circuits... 4 I Fixed Length Dual-Limb Circuits... 7 I Fixed

More information

AIRWAY Management. How to manage an airway on the battlefield TRAININGGROUNDS

AIRWAY Management. How to manage an airway on the battlefield TRAININGGROUNDS TRAININGGROUNDS How to manage an airway on the battlefield CRAWL TRAININGGROUNDS What is Airway? A Compromised airway is one of the three leading cause of preventable death on the battlefield Airway management

More information

ULTRAMED HEALTHCARE DISPOSABLES

ULTRAMED HEALTHCARE DISPOSABLES ULTRAMED HEALTHCARE DISPOSABLES The Quality You Wish Content 1- PRODUCTS INFUSION THERAPY P.2 1. I.V. CANNULA.P.2 2. I.V. INFUSION SET P.3 3. MICRO DRIP I.V.SET......P.4 4. I.V. INFUSION SET WITH FLOW

More information

DIAGNOSTIC CARDIOLOGY

DIAGNOSTIC CARDIOLOGY DIAGNOSTIC CARDIOLOGY For Your Procedural Needs Manufactured to the Highest Standards, Customised to Your Specific Needs MEDLINE PROCEDURE PACKS The items contained within this brochure are perfect for

More information

Medicina nasogastric feeding tubes

Medicina nasogastric feeding tubes Medicina nasogastric feeding tubes Medicina nasogastric feeding tubes are fully NPSA compliant and have all of the physical characteristics required for feeding, flushing and delivering medication. The

More information

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN : Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION : 10/18/12 INITIAL RE-EVALUATION ANNUAL (if required) PRN 1. Verifies physician order. 2. Gathers equipment and supplies. 3. Knocks on door

More information

Understanding Tracheostomy Care

Understanding Tracheostomy Care Understanding Tracheostomy Care Inside this guide: This guide will help you learn how to take care of your tracheostomy (trach). It is important to ask questions. You will be given time to learn. Working

More information

VBM. Product Catalogue. Accessories for Anaesthesia & Intensive Care

VBM. Product Catalogue. Accessories for Anaesthesia & Intensive Care VBM Product Catalogue Accessories for Anaesthesia & Intensive Care Table of Contents Tube Fixations Endotape 4 Tube Holder 4 Biteblock 4 Tube Fixations Tracheostomy Tracheostomy Necktapes 5 Tracheostomy

More information

Trach Tubes/Accessories

Trach Tubes/Accessories NASAL E.T. TAPE Kit #FP-11050 50/Box Overall Length: 4.75 inches (12.1 cm) Adhesive: Hypo-Allergenic Acrylate Width: 1.45 inches (3.68 cm) Material: Wet-proof Arcare Hypo-allergenic acrylate adhesive that

More information

Section 2.9 Decannulation

Section 2.9 Decannulation Bite- sized training from the GTC Section 2.9 Decannulation This is one of a series of bite- sized chunks of educational material developed by the Global Tracheostomy Collaborative. The GTC has developed

More information

LMA Airway portfolio. 3,000 published references. 300 million patient uses. Every 3 seconds an LMA airway is used somewhere in the world.

LMA Airway portfolio. 3,000 published references. 300 million patient uses. Every 3 seconds an LMA airway is used somewhere in the world. LMA Airway portfolio 3,000 published references. 300 million patient uses. Every 3 seconds an LMA airway is used somewhere in the world. Second generation SADs come highly recommended The NAP4 report 1

More information

STANDARDIZED PROCEDURE NEONATAL INTUBATION (Neonatal)

STANDARDIZED PROCEDURE NEONATAL INTUBATION (Neonatal) I. Definition This procedure is done in order to establish access to the airway in order to assist ventilation by the use of either endotracheal tube (ET tube) and bag, ET tube and continuous positive

More information

ARROW EZ-IO SYSTEM PROXIMAL HUMERUS LANDMARKING

ARROW EZ-IO SYSTEM PROXIMAL HUMERUS LANDMARKING EMS Pocket Guide ARROW EZ-IO SYSTEM PROXIMAL HUMERUS LANDMARKING A A: Place the patient s hand over the abdomen (elbow adducted and humerus internally rotated). Place your palm on the patient s shoulder

More information

INSTRUCTIONS FOR USE LMA Unique (Silicone Cuff) & LMA Unique (Silicone Cuff) Cuff Pilot

INSTRUCTIONS FOR USE LMA Unique (Silicone Cuff) & LMA Unique (Silicone Cuff) Cuff Pilot EN English Figure 1: The LMA Unique (Silicon Cuff) components INSTRUCTIONS FOR USE LMA Unique (Silicone Cuff) & LMA Unique (Silicone Cuff) Cuff Pilot CAUTION: Federal (USA) law restricts this device to

More information

Ambu AuraGain Single Use Laryngeal Mask - Sterile

Ambu AuraGain Single Use Laryngeal Mask - Sterile Product Information Ambu AuraGain Single Use Laryngeal Mask - Sterile For use by medical professionals trained in airway management only 1 Product information This product information may be updated without

More information

BALLOON. 1. PTA Balloon Catheter 1.1 ALLUNGA Description Technical Data Materials used Compliance Chart

BALLOON. 1. PTA Balloon Catheter 1.1 ALLUNGA Description Technical Data Materials used Compliance Chart BALLOON 1. PTA Balloon Catheter 1.1 ALLUNGA 1.1.1. Description 1.1.2. Technical Data 1.1.3. Materials used 1.1.4. Compliance Chart 1.1.5. Graph 1.1.6. Side by Side Comparison amg International GmbH Löhnfeld

More information

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator VariSource High Dose Rate Afterloader Procedures For Performing Breast Brachytherapy with The SAVI TM Applicator Contents I. CT Evaluation (~1 week prior to insertion) II. SAVI Applicator Implantation

More information

Breathing Process: Inhalation

Breathing Process: Inhalation Airway Chapter 6 Breathing Process: Inhalation Active part of breathing Diaphragm and intercostal muscles contract, allowing the lungs to expand. The decrease in pressure allows lungs to fill with air.

More information

Instructions/Procedure for Use of the Speaking Valve

Instructions/Procedure for Use of the Speaking Valve Instructions/Procedure for Use of the Speaking Valve Notes on the use of the speaking valve for ventilator-dependent and non-ventilator dependent patients The speaking valve is a one-way valve that allows

More information

Figure 1: LMA Unique (S) components. Figure 2: LMA Unique (S) Cuff Pilot components

Figure 1: LMA Unique (S) components. Figure 2: LMA Unique (S) Cuff Pilot components EN English INSTRUCTIONS FOR USE LMA Unique (S) & LMA Unique (S) Cuff Pilot Figure 1: LMA Unique (S) components CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

More information

Understanding Tracheostomy Care for your Child

Understanding Tracheostomy Care for your Child Understanding Tracheostomy Care for your Child 2 Inside this guide: This guide will help you learn how to take care of your child s tracheostomy (trach). It is important to ask questions. You will be given

More information

ASAHI Neurovascular Guide Wire

ASAHI Neurovascular Guide Wire ASAHI Neurovascular Guide Wire AMK-DT244 Ver.1.00 / 11TS073 Legal manufacturer Consult instructions for use Do not use if package is damaged RX ONLY Caution: Federal (USA) Law restricts this device to

More information

Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to:

Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: A H E A D O F T H E C U R V E C R A F T E D F O R P R E C I S I O N Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: Respect the thoracic

More information

Endotracheal Suctioning: In Line ETT

Endotracheal Suctioning: In Line ETT Approved by: Endotracheal Suctioning: In Line ETT Gail Cameron Senior Director Operations, Maternal, Neonatal & Child Health Programs Dr. Paul Byrne Medical Director, Neonatology Neonatal Policy & Procedures

More information

Military VBM. Medizintechnik GmbH VBM 1

Military VBM. Medizintechnik GmbH VBM 1 Military VBM Medizintechnik GmbH VBM 1 Summary Emergency Products Laryngeal Tubes... Cricothyrotomy-Sets Quicktrach... Jet-Ventilation... Cuff Pressure Gauges... Stylets, Introducers and Tube Exchangers...

More information

AirSim User's Guide. Version 2.1. True anatomy True training True to life

AirSim User's Guide. Version 2.1. True anatomy True training True to life AirSim User's Guide Version 2.1 True anatomy True training True to life Contents Contents 2 Orientation 3 Introducing AirSim 3 System 4 Materials and safety 4 Features 5 Supraglottic airway devices 7 Laryngeal

More information

The Art of. Flow Restoration. Raiden3. Non-Compliant PTCA Balloon

The Art of. Flow Restoration. Raiden3. Non-Compliant PTCA Balloon The Art of Flow Restoration Raiden3 Japan s Recognized PCI Technology Raiden3 For Both Everyday and Complex Cases Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional

More information

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient Ballard* Trach Care* Technology Instructions for Use Use this space to keep all important telephone numbers in one place. Important

More information

Oxygen Delivery Systems:

Oxygen Delivery Systems: Oxygen Delivery Systems: Oxygen Flow Meters with Heyer (SANS 1409) Connection: Stock Image X0038 O2 Flow Meter Single with Heyer connection, ball and tube type (0-15 Litre) (Brass Base) X0039 O2 Flow Meter

More information

RESUSCITATION. If baby very floppy and heart rate slow, assist breathing immediately. If baby not breathing adequately by 90 sec, assist breathing

RESUSCITATION. If baby very floppy and heart rate slow, assist breathing immediately. If baby not breathing adequately by 90 sec, assist breathing RESUSCITATION Check equipment daily, and before resuscitation Follow Resuscitation Council UK Guidelines www.resus.org.uk DRY AND COVER Cord clamping see Cord clamping below >28 weeks gestation, dry baby,

More information

Making Life Easier Easypump II

Making Life Easier Easypump II Making Life Easier Easypump II The elastomeric pump system for short- and long-term infusion therapy Elastomeric Infusion Systems Technical Guide Easypump II Disposable Elastomeric Infusion Pump System

More information

ELMED BRONCHIAL AND ESOPHAGEAL INSTRUMENTATION

ELMED BRONCHIAL AND ESOPHAGEAL INSTRUMENTATION ELMED = Surgical Cost Reduction: Quality, Reusable, Economically-priced instruments made in the U.S.A. ELMED BRONCHIAL AND ESOPHAGEAL INSTRUMENTATION The Elmed Bronchial and Esophageal instruments have

More information

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1 (19) United States (12) Patent Application Publication (10) Pub. No.: US 2008/0011304 A1 Stewart US 20080011304A1 (43) Pub. Date: Jan. 17, 2008 (54) (76) (21) (22) (60) ENDOTRACHEALTUBE WITH SUCTION ATTACHMENT

More information

respiratory care aerosol therapy

respiratory care aerosol therapy ISSUE 2.0 respiratory care aerosol therapy & manual silicone resuscitators resuscitation sets disposable resuscitators cpr pocket resuscitator silicone masks guedel airways AEROSOL, OXYGEN & HI-OXYGEN

More information

Disclosure to Promote the Right To Information

Disclosure to Promote the Right To Information इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information

More information

Pittsburgh EMS Pre-Hospital Care Monograph

Pittsburgh EMS Pre-Hospital Care Monograph Pittsburgh EMS Pre-Hospital Care Monograph COMBITUBE Center for Emergenc Medicine OF WESTERN PENNSYLVANIA DEDICATION This monograph is dedicated to the men and women of the Cit of Pittsburgh EMS Sstem

More information

HAL S User Guide

HAL S User Guide HAL S315.400 User Guide HAL is an interactive educational system developed to assist a certified instructor. It is not a substitute for a comprehensive understanding of the subject matter and not intended

More information

TruMan Trauma. User Manual Version 1:4

TruMan Trauma. User Manual Version 1:4 TruMan Trauma User Manual Version 1:4 1 Contents Page Introduction Introducing the Truman Trauma 3 Quick Set up guide Preparing the TruMan Trauma for use Tension pneumothorax Needle Decompression replacement

More information

INTERVENTIONAL CARDIOLOGY

INTERVENTIONAL CARDIOLOGY Y-Connector Newtech Y connector it is easy, fast and accurate single handed intra vascular device insertion. Perfect insertion device respecting the integrity of the coated surface with Combination of

More information

Difficult Airway Management Simulator

Difficult Airway Management Simulator MW13 Difficult Airway Management Simulator Training Model Caution Do not mark on the model and other components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot

More information

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007 Proceedings of the World Small Animal Sydney, Australia 2007 Hosted by: Next WSAVA Congress NURSES SETTING UP FOR ANAESTHESIA HOW TO PLAN FOR A SAFE ANAESTHETIC Sandra Forysth, BVSc DipACVA Institute of

More information

Diacan and Diacan S. The safe and gentle vascular access for dialysis

Diacan and Diacan S. The safe and gentle vascular access for dialysis Diacan and Diacan S The safe and gentle vascular access for dialysis Diacan Design meets function For patients & users Transparent, deformation-resistant Luer-Lock connection with optimised grip design

More information

Respiratory. Products by Galemed

Respiratory. Products by Galemed Respiratory Products by Galemed MANUAL SILICONE RESUSCITATORS RESUSCITATION SETS DISPOSABLE RESUSCITATORS CPR POCKET RESUSCITATOR SILICONE MASKS GUEDEL AIRWAYS AEROSOL MASKS OXYGEN AND HI-OXYGEN OXYGEN

More information

Huber needle EZ Huber JetCan. Quality and Experience

Huber needle EZ Huber JetCan. Quality and Experience Quality and Experience Port systems TitaJet light II Contrast Jet Port Plus II Contrast DualPort Contrast TitaJet light Low Profile Contrast T-Port Contrast T-Port Low Profile Contrast TitaJet light Jet

More information

Ambu Airway Management

Ambu Airway Management Ambu Airway Management Ambu Fields of Excellence Ambu's company philosophy has always been the desire to make life easier for doctors and to find innovative products that can save lives. Innovation and

More information

TrapLiner Catheter. Guide Extension Plus Wire Trapping

TrapLiner Catheter. Guide Extension Plus Wire Trapping TrapLiner Catheter Guide Extension Plus Wire Trapping 2-in-1 Device Guide Extension Catheter With Trapping Capabilities The TrapLiner Catheter is a rapid exchange guide extension catheter that combines

More information

Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites

Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites Page 1 of 11 Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites Version Effective Date 1 OCT 1992 2 FEB 2002 3 NOV 2011 4 DEC 2016 Document No. HKCA T2 v4 Prepared by College

More information

Material Handling Hose

Material Handling Hose Novaflex 5000 Slurry King Hose Pure Gum Liner Tough, versatile alternative to inflexible, cumbersome steel tubing. The easy handling and reusable quick-fastening flange system make installation a snap.

More information

MyoSure Tissue Removal System. For you and your patients.

MyoSure Tissue Removal System. For you and your patients. Tissue Removal System All-in-one Solution. For you and your patients. One solution for hysteroscopic tissue removal. Now there s a fast, convenient way to remove intrauterine pathology with two powerful

More information

Satisfaction. For you and your patients.

Satisfaction. For you and your patients. WOMEN S HEALTH SOLUTIONS Satisfaction. For you and your patients. Tissue Removal System & Aquilex Tissue of One solution for hysteroscopic tissue removal. Operative O.D. of 6 mm minimizes the risk of perforation

More information

McLean County Area EMS System

McLean County Area EMS System McLean County Area EMS System Procedure Guidelines EMS Medical Directors: Dr. Joel Nilles Dr. Doug Ward TABLE OF CONTENTS Preface 3 Definitions & Considerations 4 Patient Assessment 5-9 Oxygen Administration

More information