1 Head Cover BE-12 Series User Instructions for 3M Head Covers BE-12, BE-12L, BE-12B and BE-12LB (Keep these User Instructions for reference) This product helps protect against certain airborne contaminants. Misuse may result in sickness or death. For proper use, see supervisor or User Instructions, or call 3M in U.S.A., In Canada, call Technical Service at

2 TABLE OF CONTENTS GENERAL SAFETY INFORMATION...3 Intended Use...3 List of Warning and Cautions within these User Instructions...4 USE INSTRUCTIONS AND LIMITATIONS...5 Use For...5 Do Not Use For...5 Respirator Selection and Training...5 NIOSH Approval...6 NIOSH Cautions and Limitations...6 Eye and Face Protection...7 Assigned Protection Factors...7 SPECIFICATIONS...7 COMPONENTS AND REPLACEMENT PARTS...8 3M Head Cover BE-12 Series...8 NIOSH Approved Configurations for 3M BE-12 Series Head Covers...8 OPERATING INSTRUCTIONS...9 Connecting the Breathing Tube to the Head Cover...9 Connecting Breathing Tubes to the PAPR Unit...10 Inspect the Respirator Condition Thoroughly...10 Donning the Respirator...10 User Performance Check...10 INSPECTION, CLEANING AND STORAGE...11 Cleaning...11 Inspection...12 Storage...12 TROUBLESHOOTING...13 FOR MORE INFORMATION

3 GENERAL SAFETY INFORMATION Intended Use The 3 BE-12 Series Tychem QC Head Cover is a loose fitting, positive pressure respiratory inlet covering. These loose fitting facepieces, when combined with an appropriate powered air purifying blower unit (PAPR), are designed to provide respiratory protection against certain particulates, organic vapors, acid gases and other inorganic gases. (Fig. 1) The head cover features a wide-view faceshield and a Tychem QC faceseal. It is held in place on the head by a sewn-in, elastic headband. Breathing air is supplied from a breathing tube connected to a snap-in hose connector, which is sewn into the back of the head cover. Breathing air travels through the open space at the top of the head cover, down over the user s face and down through the holes in faceseal. The BE-12 Series head cover is available in polycoated Tychem QC material. Tychem QC offers splash protection against many inorganic acids, bases and other liquid chemicals such as pesticides. This fabric is made from Tychem that has been coated with 1.25 mil polyethylene. Note: This product contains no components made from natural rubber latex. Do not use the BE-12 Series head covers with facial hair that interferes with the faceseal. Users should be clean-shaven where the respirator s faceseal comes into contact with the user s face. Failure to do so may reduce the effectiveness of the respirator and result in sickness or death. Note: Inspect emergency use respirators on a monthly basis. Fig. 1 3

4 List of Warning and Cautions within these User Instructions This product helps protect against certain airborne contaminants. Misuse may result in sickness or death. For proper use, see supervisor or User Instructions, or call 3M in U.S.A., In Canada, call Technical Service at Do not use the BE-12 Series head covers with facial hair that interferes with the faceseal. Users should be clean-shaven where the respirator s faceseal comes into contact with the user s face. Failure to do so may reduce the effectiveness of the respirator and result in sickness or death. Each person using this respirator must read and understand the information in these User Instructions before use. Use of these respirators by untrained or unqualified persons, or use that is not in accordance with these User Instructions, may adversely affect respirator performance and result in sickness or death. These headpieces do not provide eye and face protection. When exposed to eye and face hazards, the respirator wearer must wear eye and/or face protectors appropriate to the hazard. Failure to do so may result in serious bodily injury or death. Do not use with parts or accessories other than those manufactured by 3M as described in these User Instructions or on the NIOSH approval label for this respirator. Do not attempt to repair or modify any component of the system except as described in these User Instructions. Failure to do so may adversely affect respirator performance and result in sickness or death. Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or death. Do not wear this respirator to enter areas where: Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH) Contaminant concentrations exceed 25 times the applicable exposure limit (the assigned protection factor for this respirator system) or the APF mandated by specific government standards, whichever is lower Contaminants that are dangerous to your health include those that you may not be able to see or smell. Leave the contaminated area immediately if any of the following conditions occur. Failure to do so may result in sickness or death. Any part of the system becomes damaged Airflow into the respirator decreases or stops Breathing becomes difficult You feel dizzy or your vision is impaired You taste or smell contaminants Your face, eyes, nose or mouth become(s) irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer provide adequate protection If this respirator fails any of the requirements of the user inspection and performance check, do not use the respirator until all necessary repairs have been made and the respirator passes the performance check. Failure to do so may adversely affect respirator performance and result in sickness or death. The exterior surface of the BE-12 Series head cover is polyethylene-coated Tychem QC and is liquid repellent. However, the material is not flame resistant and must not be used around heat, flames or sparks, or in explosive atmospheres. Consult a qualified industrial hygienist and the Permeation Guide for DuPont Fabrics to ensure that contaminant and/or liquid permeation through the uncoated seams does not occur, and for advice on the use of Tychem QC in your work environment. Failure to do so may lead to serious bodily injury or death. 4

5 The user must read and follow all User Instructions supplied with the PAPR blower unit. Incorrect operation of the PAPR motor blower could result in reduced airflow, interruption of airflow to the headpiece or contamination of breathing air and may result in sickness or death. Always don the respirator in an area where the air is clean. Failure to properly don this respirator before entering a hazardous atmosphere may result in sickness or death. Before you enter a hazardous atmosphere wearing this respirator, you must inspect the respirator, complete a user performance check, and don the respirator according to the instructions in these User Instructions and the User Instructions provided with the components of the system you are using. Failure to do so may affect respirator performance and result in sickness or death. Do not remove the respirator while you are in a hazardous atmosphere. Do not reach your hand into the facepiece in areas where the air is contaminated. Leave the contaminated area and clean contaminants from your hands before reaching inside the head cover. Failure to do so may result in sickness or death. - If excessive wear and/or damage to the respirator or its components is observed at any time, do not use the respirator until all necessary repairs have been made and the wearer has successfully completed the User Performance Check described in the Operating Instructions section of these User Instructions. Failure to do so may result in sickness or death. Do not clean head covers with detergents that contain lanolin or other oils since they may soften or distort the faceshield. Do not wipe the faceshield with strong solvents such as MEK, acetone or toluene, as those may damage or distort the faceshield. Do not soak head covers or components in cleaning solutions or solvents. Misuse may adversely affect respirator performance and may result in sickness or death. If you discover any of the wear and damage described below, discard the component and replace it with a new one. Failure to do so may adversely affect respirator performance and result in sickness or death. USE INSTRUCTIONS AND LIMITATIONS Important Before use, the wearer must read and understand these User Instructions. Keep these instructions for reference. Use For Respiratory protection against certain airborne contaminants including particulates (dusts, fumes, mists, radionuclides and asbestos); organic vapors; acid gases; and other inorganic gases Do Not Use For Atmospheres where oxygen concentration is below 19.5%. Concentrations of contaminants that are unknown; immediately dangerous to life or health (IDLH); exceeds applicable maximum use limitations under local standards or OSHA standards, whichever is lower. Refer to additional limitations and cautions under NIOSH Cautions and Limitations. Respirator Selection and Training Use of these respirators must be in accordance with applicable health and safety standards, respirator selection tables contained in such publications as American National Standards Institute (ANSI) Z , Canadian Standards Association (CSA) Standard Z94.4 or pursuant to the recommendations of an industrial hygienist. The employer must have a written respirator program in place that complies with the Occupational Safety and Health Administration (OSHA) respiratory protection standard found in 29 CFR prior to using any respirator. In Canada, follow CSA standard Z94.4 or the requirements of the authority having jurisdiction in your region. Before use, the employer must assure that each respirator user has been trained by a qualified person in the proper use and maintenance of the respirator according to the instructions contained in these User Instructions and other applicable User Instructions. 5

6 Each person using this respirator must read and understand the information in these User Instructions before use. Use of these respirators by untrained or unqualified persons, or use that is not in accordance with these User Instructions, may adversely affect respirator performance and result in sickness or death. NIOSH Approval For a listing of the components of NIOSH approved 3M TM Respirator Systems using 3M BE-Series Head Covers, refer to the NIOSH approval label, which accompanies the 3M PAPR Blower Unit. NIOSH Cautions and Limitations A Not for use in atmospheres containing less than 19.5 percent oxygen. B Not for use in atmospheres immediately dangerous to life or health. C Do not exceed maximum use concentrations established by regulatory standards. F Do not use powered air-purifying respirators if airflow is less than four cfm (115 lpm ) for tight fitting facepieces or six cfm (170 lpm) for head covers and/or helmets. H Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and canisters are replaced before breakthrough occurs. I Contains electrical parts which have not been evaluated as an ignition source in flammable or explosive atmospheres by MSHA/NIOSH. J Failure to properly use and maintain this product could result in injury or death. K The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this respirator when used against formaldehyde. L Follow the manufacturer's User s Instructions for changing cartridges, canister and/or filters. M All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O Refer to User s Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P NIOSH does not evaluate respirators for use as surgical masks. 6

7 Eye and Face Protection These head covers do not provide eye and face protection. When exposed to eye and face hazards, the respirator wearer must wear eye and/or face protectors appropriate to the hazard. Failure to do so may result in serious bodily injury or death. Assigned Protection Factors 3M recommends an assigned protection factor (APF) of 25 for powered air purifying respirators with loose fitting headpieces. In Canada, follow CSA Z94.4 or the requirements of the authority having jurisdiction in your region. SPECIFICATIONS Weight BE-12 Head Cover: Approx lb (77 g) Airflow range Faceshield Head protection Noise level Head cover fabric 6 to 15 cfm (170 to 425 lpm) Clear acetate, 80 in 2 (516 cm 2 ) viewing area None Less than 80 dba (Excluding external noise) Tychem QC: Tychem fabric with 1.25 mil polyethylene coating Temperature Range 0 to 120 degrees F (-18 to 48 degrees C) Heat and flame resistance Tychem QC head covers are not flame resistant and must not be used around heat, flames, sparks or in potentially explosive atmospheres. 7

8 COMPONENTS AND REPLACEMENT PARTS Do not use with parts or accessories other than those manufactured by 3M as described in these User Instructions or on the NIOSH approval label for this respirator. Do not attempt to repair or modify any component of the system except as described in these User Instructions. Failure to do so may adversely affect respirator performance and result in sickness or death. 3M Head Cover BE-12 Series Product Name/Description Current BE-12 Series Product Number Formerly R-Series Product Number Head Cover, White, Regular, Tychem QC (3/pk) BE R03 Head Cover, White, Regular, Tychem QC BE R50 (50/pk) Head Cover, White, Large, Tychem QC (3/pk) BE-12L R03 Head Cover, White, Large, Tychem QC (50/pk) BE-12L R50 Head Cover, Blue, Regular, Tychem QC (3/pk) BE-12B R03 Head Cover, Blue, Regular, Tychem QC (50/pk) BE-12B R50 Head Cover, Blue, Large, Tychem QC (3/pk) BE-12LB R03 Head Cover, Blue, Large, Tychem QC (50/pk) BE-12LB R50 Protective Overlay (for faceshield) (10/pack) R R10 Note: 3M R-Series to BE-Series denotes a product number change only no change to product. NIOSH Approved Configurations for 3M BE-12 Series Head Covers BE-12 Tychem QC Head Covers (BE-12-3, BE-12-50, BE-12L-3, BE-12L-50, BE-12LB-3 and BE- 12LB-50) 3M PAPR / Air Supply Device Air-Mate Belt-Mounted PAPR Breathe Easy Belt-Mounted PAPR Breathing Tube Options BE-224, Polyurethane, 38 in long (formerly R01) R01, 33 in long R01, 25 in long 8

9 OPERATING INSTRUCTIONS Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or death. Do not wear this respirator to enter areas where: Atmospheres are oxygen deficient Contaminant concentrations are unknown Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH) Contaminant concentrations exceed 25 times the applicable exposure limit (the assigned protection factor for this respirator system) or the APF mandated by specific government standards, whichever is lower Contaminants that are dangerous to your health include those that you may not be able to see or smell. Leave the contaminated area immediately if any of the following conditions occur. Failure to do so may result in sickness or death. Any part of the system becomes damaged Airflow into the respirator decreases or stops Breathing becomes difficult You feel dizzy or your vision is impaired You taste or smell contaminants Your face, eyes, nose or mouth become(s) irritated You suspect that the concentration of contaminants may have reached levels at which this respirator may no longer provide adequate protection If this respirator fails any of the requirements of the user inspection and performance check, do not use the respirator until all necessary repairs have been made and the respirator passes the performance check. Failure to do so may adversely affect respirator performance and result in sickness or death. If you have any doubts about the applicability of the equipment to your job situation, consult an industrial hygienist or call the technical service department of 3M OH&ESD at In Canada, call Technical Service at Connecting the Breathing Tube to the Head Cover Push the end of the breathing tube with the slotted hose connector into the rear of the head cover until it snaps into place. The exterior surface of the BE-12 Series head cover is polyethylene-coated Tychem QC and is liquid repellent. However, the material is not flame resistant and must not be used around heat, flames or sparks, or in explosive atmospheres. Consult a qualified industrial hygienist and the Permeation Guide for DuPont Fabrics to ensure that contaminant and/or liquid permeation through the uncoated seams does not occur, and for advice on the use of Tychem QC in your work environment. Failure to do so may lead to serious bodily injury or death. 9

10 Connecting Breathing Tubes to the PAPR Unit Refer to the NIOSH Approved System Configurations table for a list of approved powered air purifying respirator (PAPR) belt-mounted units and breathing tubes needed to form a complete positive pressure respirator system. The user must read and follow all User Instructions supplied with the PAPR blower unit. Incorrect operation of the PAPR motor blower could result in reduced airflow, interruption of airflow to the headpiece or contamination of breathing air and may result in sickness or death. Check that the rubber o-ring gasket is in place at the end of the breathing tube connector. Position the breathing tube connector so that its two locking studs are aligned with the openings of the two L-shaped slots on the PAPR or SAR valve outlet fitting. Press in straight and twist so that the locking studs are engaged at the end of the L-shaped slots. Inspect the Respirator Condition Thoroughly Each time the respirator is used, you must complete the inspection procedures recommended in the Inspection, Cleaning and Storage section. Inspect PAPR components according to the instructions in the User Instructions provided with the applicable components. Donning the Respirator Always don the respirator in an area where the air is clean. Failure to properly don this respirator before entering a hazardous atmosphere may result in sickness or death. The 3M BE-12 Series head cover system is made from polycoated Tychem QC material in regular (for head sizes 6 1/2 to 7 3/8) and large (for head sizes 7 to 8). Since the sizing guidelines are general, the best fitting size of head cover for you may depend on your facial size and shape. Select the size that fits most comfortably and matches your head size. Remove the protective covering from the faceshield. To achieve the best fit, the head cover should be worn with the headband around your forehead and the straps in the top of the head cover in contact with the top of your head. The elasticized edge of the faceseal should come in contact with your face under the chin and along the cheeks. It is important to ensure the breathing tube is not twisted after the complete system has been donned. Turn on the battery pack to draw ambient air through the filter/cartridge. With the respirator in operation, enter the contaminated area, breathing normally. Keep the air supply hose or PAPR assembly away from equipment, vehicles and other physical and chemical hazards. User Performance Check 1. Prior to connecting the breathing tube to the head cover, complete the performance check and verify that the airflow is adequate according to the User Instructions provided with the 3M beltmounted powered air purifying respirator. 2. Observe the condition of the breathing tube in the air inlet at the back of the head cover. Verify that the air inlet is not twisted or obstructed in any way. 3. Place your hand inside the head cover, in the area above the faceshield. You should feel the air entering the head cover. 10

11 Enter the Contaminated Area Before you enter a hazardous atmosphere wearing this respirator, you must inspect the respirator, complete a user performance check, and don the respirator according to the instructions in these User Instructions and the User Instructions provided with the components of the system you are using. Failure to do so may affect respirator performance and may result in sickness or death. With the respirator in operation, enter the contaminated area, breathing normally. Keep the air supply hose or PAPR assembly away from equipment, vehicles and other physical and chemical hazards. Do not remove the respirator while you are in a hazardous atmosphere. Do not reach your hand into the facepiece in areas where the air is contaminated. Leave the contaminated area and clean contaminants from your hands before reaching inside the head cover. Failure to do so may result in sickness or death. Remove the Respirator in a Clean Area Clean your hands of any contaminants before reaching inside the head cover for any reason. Refer to the Inspection, Cleaning and Storage section of these User Instructions for cleaning, inspection and storage information. INSPECTION, CLEANING AND STORAGE After each use, inspect the head cover assembly to identify signs of damage or wear that may affect performance of the respirator and reduce the degree of protection provided. For a list of replacement parts, refer to the Components and Replacement Parts section. The Troubleshooting section contains a troubleshooting guide to help you identify the proper action to take for specific problems that may be detected. If excessive wear and/or damage to the respirator or its components is observed at any time, do not use the respirator until all necessary repairs have been made and the wearer has successfully completed the User Performance Check described in the Operating Instructions section of these User Instructions. Failure to do so may result in sickness or death. Cleaning Follow the hygiene practices established by your employer for the specific contaminants to which you have been exposed. To remove paint or other coatings from the faceshield, you may wipe the faceshield with mineral spirits. 11

12 Do not clean head covers with detergents that contain lanolin or other oils since they may soften or distort the faceshield. Do not wipe the faceshield with strong solvents such as MEK, acetone or toluene, as those may damage or distort the faceshield. Do not soak head covers or components in cleaning solutions or solvents. Misuse may adversely affect respirator performance and may result in sickness or death. Inspection Visually examine the condition of the head cover shell, head suspension, faceshield and breathing tube after each use. If you discover any of the wear and damage described below, discard the component and replace it with a new one. Failure to do so may adversely affect respirator performance and result in sickness or death. Head Cover Check that there are no dents or cracks in the head cover assembly. Look closely at the stitching. There should be no tears that could permit contaminated air to enter the head cover. Faceshield Look for scratches or other visual distortions that make it difficult to see through the faceshield. Breathing Tube Carefully examine the entire breathing tube. Look for tears, holes or cracks. Bend the tube to verify that it is flexible. Storage Store your head cover at room temperature in a dry area that is protected from exposure to hazardous contaminants. 12

13 TROUBLESHOOTING Use the table below to help identify possible causes and corrective action for problems you may experience. Problem Possible Cause Corrective Action Poor visibility through Faceshield cover is scratched or Remove cover and replace face shield coated with debris Wipe off debris Breathing tube pulls head cover out of comfortable position Faceshield is scratched or coated with debris Breathing tube too long Breathing tube too short Dispose of head cover and replace it with a new head cover Consider using face shield covers Wipe off debris Select appropriate length breathing tube (26 inch and 33 inch lengths are available) Head cover noisy Twisted breathing tube inlet Assure that the breathing tube is not twisting the inlet opening Low airflow Breathing tube disconnected at head cover Reattach tube Battery needs charging, PAPR filter is loaded. See User Instructions for 3M beltmounted PAPR for guidance FOR MORE INFORMATION In United States, contact: Internet: Technical Assistance: For other 3M products: M-HELPS or M Occupational Health and Environmental Safety Division 3M Center, Building W-70 St. Paul, MN Tychem QC is a registered trademark of DuPont. 3M

Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR

Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR (Keep these User Instructions for reference) This product helps protect against certain airborne contaminants. Misuse may

More information

Hoods R-Series User Instructions for 3M TM Hoods and and 3M TM Hood , Butyl Rubber

Hoods R-Series User Instructions for 3M TM Hoods and and 3M TM Hood , Butyl Rubber Hoods R-Series User Instructions for 3M TM Hoods 522-01-11 and 522-02-17 and 3M TM Hood 522-02-23, Butyl Rubber (Keep these User Instructions for reference) This product helps protect against certain airborne

More information

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable User Instructions for 3M Organic Vapor Respirator, P95 Assembly 51P71/52P71/53P71 Important: Keep these User

More information

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable User Instructions for 3M Organic Vapor Respirator Assembly 5101/5201/5301; 3M Organic Vapor/Acid Gas Respirator Assembly 5103/5203/5303;

More information

Powerflow TM Face-Mounted Powered Air Purifying Respirator User Instructions for 3M TM Powerflow TM PAPR

Powerflow TM Face-Mounted Powered Air Purifying Respirator User Instructions for 3M TM Powerflow TM PAPR Powerflow TM Face-Mounted Powered Air Purifying Respirator User Instructions for 3M TM Powerflow TM PAPR Important: Before use, the wearer must read and understand these User Instructions. Keep these User

More information

Phalanx Alpha Phalanx Beta and Ultra Elite

Phalanx Alpha Phalanx Beta and Ultra Elite Phalanx Alpha Phalanx Beta and Ultra Elite riot control agent gas masks instructions parts list NIOSH approved for respiratory protection in atmospheres containing CN and CS and particulates under the

More information

3 Versaflo S-Series Hoods and Headcovers

3 Versaflo S-Series Hoods and Headcovers 3 Versaflo S-Series Hoods and Headcovers User Instructions for: S-103S S-103L S-133S S-133L S-133SB S-133LB S-333S S-333L S-403S S-403L S-433S S-433L S-533S S-533L S-605 S-607 S-707 S-805 S-807 Important:

More information

(Keep these User Instructions for reference)

(Keep these User Instructions for reference) GVP Series Belt-Mounted Powered Air Purifying Respirator Assembly User Instructions for 3M Belt-Mounted PAPR Assembly GVP-1NiMH, GVP-1UNiMH, GVP-CBNiMH, GVP-1, GVP- 1U, GVP-CB and 3M PAPR Unit GVP-100

More information

Important: Keep these instructions for reference.

Important: Keep these instructions for reference. V-Series Air Control Devices User Instructions for 3M TM Vortex Cooling Assembly V-100 and V-100SS (Stainless Steel), 3M TM Vortemp TM Heating Assembly V-200 and V-200SS (Stainless Steel), 3M TM Air Regulating

More information

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care 818188_b.qxd 2/20/01 7:38 AM Page 1 UltraFilter respirator with Ultravue or Ultra Elite Facepiece instructions for use and care This booklet, including the warnings and cautions inside, must be read and

More information

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters UNITED STATES Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters This information is about the respirator fit testing requirements for any worker

More information

Respiratory Protection. Program

Respiratory Protection. Program Respiratory Protection Program Respiratory Protection Program Table of Contents A. General B. Selection of Respirators C. Medical Screening D. Fit Testing E. Respirator Use Instructions F. Respirator Inspection

More information

3 Choosing the Right Respirator

3 Choosing the Right Respirator 3 By: Jeanne Bidwell 3M Occupational Health and Environmental Safety Division Originally published February, 1997 for Plant Engineering Magazine Selecting respirators to help protect workers from airborne

More information

Dual Airline Supplied Air Respirators User Instructions

Dual Airline Supplied Air Respirators User Instructions Dual Airline Supplied Air Respirators User Instructions Important: Keep these User Instructions for reference This product helps protect against certain airborne contaminants. Misuse may result in sickness

More information

BREATHE SAFELY: The Proper Use of Respiratory Protection

BREATHE SAFELY: The Proper Use of Respiratory Protection BREATHE SAFELY: The Proper Use of Respiratory Protection This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of

More information

8200/07023 Particulate Respirator N95

8200/07023 Particulate Respirator N95 8200/07023 Particulate Respirator N95 User Instructions (Keep these User Instructions for reference) 07023 is a catalog number only. NIOSH approved as 3M TM 8200 Particulate Respirator N95. See insert

More information

A. APPLICATIONS 1. WARNING TO USER

A. APPLICATIONS 1. WARNING TO USER IV. MOLDEX INDUSTRIAL 42 CFR 84 DISPOSABLE RESPIRATOR USER INSTRUCTIONS Each specific model may contain additional warnings and instructions. You MUST refer to the packaging for specific instructions.

More information

Particulate Respirator N95

Particulate Respirator N95 Particulate Respirator N95 9210+/*37192, 9211+/37193* User Instructions IMPORTANT: Keep User Instructions for reference *37192 and 37193 are catalog numbers only. NIOSH approved as 3M Particulate Respirator

More information

VFlex 9105/9105S Particulate Respirator N95

VFlex 9105/9105S Particulate Respirator N95 VFlex 9105/9105S Particulate Respirator N95 User Instructions IMPORTANT: Keep these User Instructions for reference 3M and VFlex are trademarks of 3M Company, used under license in Canada 98-0060-0156-8/2

More information

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference) 8515/07189 Respirator N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference) 07189 is a catalog number only. NIOSH approved as 3MTM

More information

8214/8514/07187 Respirator N95 Particulate

8214/8514/07187 Respirator N95 Particulate 8214/8514/07187 Respirator N95 Particulate 3M recommended for welding on stainless steel, aluminum, galvanized steel, and other applications where ozone and nuisance organic vapors* may be present. User

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

Comfort. Versatility. Simplicity. 3M Versaflo Respirator Systems. Highly Versatile Systems for Respiratory Protection

Comfort. Versatility. Simplicity. 3M Versaflo Respirator Systems. Highly Versatile Systems for Respiratory Protection 3M Versaflo Respirator Systems Comfort Simplicity Versatility Highly Versatile Systems for Respiratory Protection 3M Versaflo Respirator Systems are a comfortable, comprehensive approach to worker protection.

More information

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING Leader s Guide 2007 ERI Safety Videos THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist

More information

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference) 8516 Respirator N95 Particulate 3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference) *3M recommended for relief

More information

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating 8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating User Instructions (Keep these instructions for reference) 1 This respirator helps

More information

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

Nuisance level organic vapor relief* User Instructions (Keep insert for reference) 8577 Respirator P95 Particulate Nuisance level organic vapor relief* User Instructions (Keep insert for reference) *3M recommended for relief against nuisance levels of organic vapor. (Nuisance level organic

More information

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference)

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference) DO-IT-YOURSELF / HOMEOWNER USER INSTRUCTIONS 3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference) This respirator contains no components made from natural

More information

9210/37021, 9211/37022* Particulate Respirator N95

9210/37021, 9211/37022* Particulate Respirator N95 9210/37021, 9211/37022* Particulate Respirator N95 User Instructions (Keep insert for reference) *37021 and 37022 are catalog numbers only. NIOSH approved as 3M 9210 N95 Particulate Respirator and 3M 9211

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM A P P E N D I X 14 RESPIRATORY PROTECTION PROGRAM AP14.1. Purpose. AP14.2. Policy. To establish a written Respiratory Protection Program for CBP. The purpose of an effective respirator program is to provide

More information

How to Make a Respirator Program and Calculating the Cost

How to Make a Respirator Program and Calculating the Cost How to Make a Respirator Program and Calculating the Cost Dan Curts CIH,ROH,CRSP Goals Understand how to develop a respiratory protection program Understand regulatory requirements Understand the costs

More information

3M Occupational Health and Environmental Safety Division. Options

3M Occupational Health and Environmental Safety Division. Options 3M Occupational Health and Environmental Safety Division 3M Respiratory Options During times of global and/or localized influenza outbreaks, available supplies of certain respirators can become constrained.

More information

HAZWOPER 8-Hr Refresher Aug. 20, 2012

HAZWOPER 8-Hr Refresher Aug. 20, 2012 Institute for Tribal Environmental Professionals Tribal Lands and Environment: A National Forum on Solid Waste, Emergency Response, Contaminated Sites and USTs August 20-23, 2012 Coos Bay, Oregon HAZWOPER

More information

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower. 1 Star Mask paint spray respirator CHARACTERISTICS Star Mask is a respirator with exchangeable pre-filters and gas-filters. Star Mask protects against mist of paint, lacquer, enamel, pesticide, organic

More information

Respiratory Protection for Producers

Respiratory Protection for Producers March 2005 Agdex 086-8 Respiratory Protection for Producers Dust and harmful gases can cause immediate and long-term respiratory problems. Wearing protective equipment is vitally important when working

More information

Respiratory Protection

Respiratory Protection Respiratory Protection University of Tennessee Safety Program IH-003 Document Contact: EHS-General Safety Date effective: January 1, 2006 Revision Date: March 1, 2014 Purpose It shall be the policy of

More information

University of Dayton Respiratory Protection Program 29 CFR

University of Dayton Respiratory Protection Program 29 CFR University of Dayton Respiratory Protection Program 29 CFR 1910.134 What to expect from this training: Employees who are required to use respirators must be trained such that they can demonstrate knowledge

More information

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11 PURPOSE This policy provides requirements on the selection, use, care, and maintenance of respiratory protection. Also included is information and guidelines on training, medical evaluations, recordkeeping

More information

Checklist for care of Respirators

Checklist for care of Respirators Checklist for care of Respirators Inspect the respirator before and after each use and during cleaning. Inspect equipment designated for "emergency use" at least monthly, and after each use. Replace all

More information

RESPIRATORY PROTECTION

RESPIRATORY PROTECTION RESPIRATORY PROTECTION OSHA 29 CFR 1910.134 PPT-042-01 1 Respiratory Protection Respirators shall be provided when necessary to protect the health of employees from breathable hazards (should be used as

More information

Supplied Air Respirators

Supplied Air Respirators Supplied Air Respirators Supplied Air Respirators (SAR) are designed to deliver clean air to the worker. The air* can be supplied from a high pressure compressor (breathable plant air). This clean air

More information

Standards of Practice Respiratory Protection: Appendix C

Standards of Practice Respiratory Protection: Appendix C Document Authority: EHS Coordinator Standards of Practice Respiratory Protection: Appendix C Document Custodian: EH&S Coordinator Effective Date: 09.01.15 Issuing Dept: College of Agriculture EH&S Next

More information

(MPV-625) 8 AIR SUPPLIED RESPIRATOR

(MPV-625) 8 AIR SUPPLIED RESPIRATOR SERVICE BULLETIN Replaces SB-25-050 165013 (MPV-625) 8 AIR SUPPLIED RESPIRATOR IMPORTANT: Read and follow this service literature before you use the respirator. The literature explains the proper use,

More information

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets 3M Versaflo TR-300-HIK Heavy Industry PAPR Kit 1/Case 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets Comfort Simplicity Versatility 3M Versaflo M-Series Headgear for Powered and Supplied Air

More information

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision 1.0 Intent: 2.0 Scope: It is the intention of the University at Albany to provide a

More information

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS H E A LT H & S A F E T Y AT WO R K HSWA AC T FACT SHEET RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS Respiratory protective equipment (RPE) is a type of personal protective equipment (PPE) that

More information

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training University of Alabama Office of Environmental Health and Safety Respirator Protection Training Medical Reasons That Could Prohibit the Use of a Respirator A history of pulmonary or lung problems such as:

More information

Respiratory Protection

Respiratory Protection Respiratory Protection Everything You Wanted to Know About Respiratory Protection and Probably a Bit More. Instructor: Mary Schlagel Northern Illinois University Environmental Health & Safety Dept. 815-753-0404

More information

Respiratory Protection Basics

Respiratory Protection Basics Michigan Safety Conference Respiratory Protection Basics Date: April 17, 2018 0 16 April 3M 2018. All Rights Reserved. Presenter Don Rust, CIH, CSP Technical Service Specialist 3M Personal Safety Division

More information

Personal Protective Equipment 29 CFR 1926

Personal Protective Equipment 29 CFR 1926 Personal Protective Equipment 29 CFR 1926 OSHA- PPE http://www.osha.gov/publications/osha31 51.html NIOSH s Protective Clothing Web Page http://www.cdc.gov/niosh/npptl/topics/prot clothing/ 1926.95 PPE

More information

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451. Calvin College Respiratory Protection Program Prepared by: Date: Heather Chapman 10/7/10 Approved by: Cabinet Revision 2 Date: 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory

More information

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres Working in an area with insufficient oxygen Situations where harmful dusts,

More information

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets Comfort Simplicity Versatility 3M Versaflo M-Series Headgear for Powered and Supplied Air Respirators 3M.com/Versaflo 3M Versaflo M-Series Respiratory

More information

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module PRES0389 7/05-1 Powered Air Purifying Respirators (PAPR) Reduce the risk of transmission of infectious agents spread

More information

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM Risk Management Department August, 2008 ALBUQUERQUE PUBLIC SCHOOLS RISK MANAGEMENT DEPARTMENT RESPIRATORY PROTECTION PROGRAM TABLE OF CONTENTS

More information

Respiratory Protection Self-Inspection Checklist

Respiratory Protection Self-Inspection Checklist Respiratory Protection Self-Inspection Checklist Guidelines: This checklist applies to the use of either atmosphere-supplying or air-purifying respirators being worn, voluntarily or otherwise, for comfort

More information

Respiratory Protection Program 29CFR

Respiratory Protection Program 29CFR Respiratory Protection Program 29CFR1910.134 Program Objectives OSHA requires employers to establish and implement procedures for the proper use of respirators by doing the following: Verify the need for

More information

User Advisory Notice BE-10BR Hood Immediate Action Required

User Advisory Notice BE-10BR Hood Immediate Action Required User Advisory Notice BE-10BR Hood Immediate Action Required September 30, 2016 Dear Valued Customer, The purpose of this document is to communicate a valve replacement notice as well as new use and storage

More information

Respiratory Protection Self Inspection Checklist

Respiratory Protection Self Inspection Checklist Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Respiratory Protection Self Inspection Checklist Guidelines: This checklist covers some

More information

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE From the April 26, 2018 Webinar- Respiratory Protection and Medical Surveillance for Silica? OSHA s Hierarchy

More information

CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference.

CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3 RESPIRATORY COMPONENT CONCEPT 4 WARNINGS 5 RESPIRATOR OPERATION

More information

3 Dual Airline Supplied Air Respirators User Instructions. Respirateurs à adduction d air à deux arrivées d air Directives d utilisation

3 Dual Airline Supplied Air Respirators User Instructions. Respirateurs à adduction d air à deux arrivées d air Directives d utilisation 3 Dual Airline Supplied Air Respirators User Instructions Respirateurs à adduction d air à deux arrivées d air Directives d utilisation Respiradores con Suminsitro de Linea de Aire Dual Instrucciones de

More information

SUPPLIED-AIR RESPIRATOR 9650 Series LOW PRESSURE, CONTINUOUS FLOW CLASS OPERATION MANUAL

SUPPLIED-AIR RESPIRATOR 9650 Series LOW PRESSURE, CONTINUOUS FLOW CLASS OPERATION MANUAL SUPPLIED-AIR RESPIRATOR 9650 Series LOW PRESSURE, CONTINUOUS FLOW CLASS OPERATION MANUAL DO NOT USE this respirator until you completely read and understand this Operation Manual. You are required to inspect

More information

ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D

ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D U S E R M A N U A L ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D Read and understand all instructions before using

More information

"RESPIRATORY PROTECTION AND SAFETY"

RESPIRATORY PROTECTION AND SAFETY PRESENTER'S GUIDE "RESPIRATORY PROTECTION AND SAFETY" Training for the OSHA RESPIRATORY PROTECTION STANDARD Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS

More information

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06) Texas Department of Insurance Respiratory Protection Provided by Workers Health & Safety HS01-027B (1-06) Contents Introduction... 3 Definitions... 3 Approved Respirators... 3-4 New Respirator Selection

More information

RMM 311 Respiratory Protection Program Page 2 March 2013

RMM 311 Respiratory Protection Program Page 2 March 2013 RMM 311 Respiratory Protection Program Page 2 Z180.1-00 Compressed Breathing Air and Systems. 3.3 NIOSH Standard 42 CFR 84 (1995) for Non Powered Particulate Filtering Respirators 3.4 McMaster University

More information

RESPIRATORY PROTECTION PROCEDURE

RESPIRATORY PROTECTION PROCEDURE RESPIRATORY PROTECTION PROCEDURE 1. PURPOSE The purpose of this procedure is to protect the health and safety of University faculty and staff who work in areas that may have irritating or hazardous atmospheres.

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Purpose In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to glutaraldehyde. Applicability This policy is applicable to all Temple University

More information

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding 3M Disposable and Reusable Respirators for Welding Breathe easily. Weld safely. Comfortable, low-profile disposable and reusable respirators compatible with 3M Speedglas welding helmets.* * Since head

More information

EP30g, Respiratory Protection.pdf

EP30g, Respiratory Protection.pdf Respiratory Protection University of California Irvine Medical Center Environmental Health and Safety Procedures Section: Safety Reviewed/Revised: 05/10 1. Introduction Good health depends on breathing

More information

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection RESPIRATORY PROTECTION PROGRAM 1910.134 OSHA Respiratory Protection Table of Contents Introduction... 3 Scope... 3 Definitions... 3 Responsibilities... 5 Voluntary Use... 6 Use Requirements... 6 Program

More information

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of. 3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems Work in a World of Comfort 3M TM Versaflo TM AP-600 Series Air Filtration Panels (AFP)

More information

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield Page: 1 of 23 Operating instruction SR 540 Face Shield Page: 2 of 23 General information The SR 540 Face Shield can be used together with the SR 500 Powered Air-Purifying Respirator system of components

More information

Respiratory Protection Training

Respiratory Protection Training Respiratory Protection Training Disclaimer IMPORTANT NOTICE: This risk control training program provided by PMA Companies is intended to help support your loss prevention efforts. It is not intended to

More information

Respiratory Protection

Respiratory Protection Respiratory Protection Purpose The purpose is to establish a set of guidelines for the selection of respiratory protection equipment, situations for its use, and training in the use of the respirator required.

More information

3M Select Software United Kingdom and Ireland

3M Select Software United Kingdom and Ireland 3M Select Software United Kingdom and Ireland Introduction to Select and Service Life Software 3M Select Software is designed to help you choose the appropriate 3M respirator for your work environment.

More information

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION WARNING This manual must be read carefully by all persons who have who will have the responsibility

More information

Respiratory Protection Programs Policy

Respiratory Protection Programs Policy Applicable Legislation: Occupational Health and Safety Act (OHSA), R.S.O. 1990, Sections 25 to 28 O. Reg. 851, R.R.O. 1990, Industrial Establishments, 79, 127, 128(2)(b), 130, 137, 138 O. Reg. 833/90 Control

More information

low maintenance respirator

low maintenance respirator low maintenance respirator instructions This booklet, including the warnings and cautions inside, must be read and followed carefully by all persons who use or maintain this product, including those who

More information

Personnel Protective Equipment

Personnel Protective Equipment Personal Protective Equipment For Law Enforcement Personnel Protective Equipment Course Objectives 1. The participant will be able to choose which respiratory protection should be used for a given hazard.

More information

National Personal Protective Technology Laboratory

National Personal Protective Technology Laboratory National Personal Protective Technology Laboratory Robert Stein CV&SDB/NPPTL/NIOSH Respiratory Protection Let s Clear the Air Quality Partnerships Enhance Worker Safety and Health DISCLAIMER: The findings

More information

Respiratory Protection in Agriculture

Respiratory Protection in Agriculture Respiratory Protection in Agriculture Glen H. Hetzel, Extension Agricultural Engineer Virginia Tech Introduction Who Needs Respiratory Protection? THOSE working in dusty fields and buildings THOSE handling

More information

AIRFED 2100 Full Face Breathing Mask

AIRFED 2100 Full Face Breathing Mask AIRFED 2100 Full Face Breathing Mask Instruction Manual IMPORTANT Before use, adjustment or maintenance, it is important to read this instruction manual very carefully. Failure to follow these instructions

More information

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE SCBA MAINTENANCE SCOPE Stoney Point Fire Department Self-contained breathing apparatus provides respiratory protection under conditions of oxygen deficiency or in concentrations of toxic gases immediately

More information

Respiratory Protection Program

Respiratory Protection Program California State University, Chico Department of Environmental Health and Safety Table of Contents Section 1.0 Introduction... 1-1 2.0 Responsibilities... 2-1 2.1 Environmental Health and Safety Responsibilities...

More information

The Following information is based on material prepared by the American Lung Association

The Following information is based on material prepared by the American Lung Association The Following information is based on material prepared by the American Lung Association RESPIRATORY PROTECTION FROM INHALATION HAZARDS The inhalation of harmful dusts, toxic gases and vapors at fire and

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM RESPIRATORY PROTECTION PROGRAM A. Introduction: Due to the potential risks involved from exposure to hazardous substances and atmospheres, UNE has developed a Respiratory Protection Program to protect

More information

Helping protect people At work, at home, for life

Helping protect people At work, at home, for life Helping protect people At work, at home, for life DIOSH Days: Respiratory Protection-General Overview February 29, 2012 3M 2010. All Rights Reserved. Agenda: Introduction General Overview Types of Hazards

More information

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Entry to these spaces must be rigorously controlled to prevent serious injury or death. Chapter 6 - Confined Spaces Chapter 6 Confined Spaces Definitions A confined space is defined as any structure that must be entered and that has or may contain dangerous concentrations of hazardous gases

More information

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY Introduction This document sets out the Health & Safety arrangements we have established for BGC Holdings Ltd, and all subsidiary and associated

More information

Ontario Operations PMP - Daily Safety Message. Respirator Safety

Ontario Operations PMP - Daily Safety Message. Respirator Safety Ontario Operations 2017 PMP - Daily Safety Message Respirator Safety Context: Respirators only work when they are selected, maintained, and used properly. Respirator Types, Fit and Maintenance: There are

More information

City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015

City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015 A. Executive Summary and Introduction City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015 1. Annual fit test is required for all employees who will be required to wear a respirator as a part

More information

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

RPE with a UK Standard Assigned Protection Factor 10 (APF10) Health and Safety Executive R COSHH essentials: Supplementary advice RPE with a UK Standard Assigned Protection Factor 10 (APF10) Control approach R Respiratory protective equipment (RPE) The Control of

More information

North RU8500 Series Half Masks

North RU8500 Series Half Masks North RU8500 Series Half Masks The RU8500 Series is a silicone half mask compatible with the North N-Series cartridges and filters. The half mask has a speech diaphragm for improved voice clarity and is

More information

Vanguard and Vanguard II Helmets

Vanguard and Vanguard II Helmets Vanguard and Vanguard II Helmets WARNINGS, CAUTIONS, AND INSTRUCTIONS THIS BOOKLET MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO WEAR OR MAINTAIN THIS HELMET, INCLUDING THOSE WHO HAVE ANY RESPONSI- BILITY

More information

NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT CONCEPT 5 !WARNINGS! 6 RESPIRATOR OPERATION 8

NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT CONCEPT 5 !WARNINGS! 6 RESPIRATOR OPERATION 8 INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT

More information

Respiratory Protection Program

Respiratory Protection Program Respiratory Protection Program General It is necessary to protect persons who may be exposed to harmful mists, smoke, vapors, aerosols, pathogens, etc. or to an oxygen deficient atmosphere. Whenever possible,

More information

UCSF. Respiratory Protection Manual

UCSF. Respiratory Protection Manual UCSF Respiratory Protection Manual 2013 Office of Environmental Health and Safety University of California, San Francisco 50 Medical Center Way, San Francisco 94143-0942 Table of Contents I. INTRODUCTION...

More information