Focus Area Campaign for November 2014 SCBA

Size: px
Start display at page:

Download "Focus Area Campaign for November 2014 SCBA"

Transcription

1 Focus Area Campaign for November 2014 SCBA SMS Reference SBP FTM FM 13 FM ANX 1,2 &3 and APP 1 H&S H&S ECM ECM ECM MTM Guidance for the FOCUS area Drill Planner - Use of SCBA and EEBD and precautions Fireman s Outfit - Ensure that the details of the ship specifc equipment is entered in the section for SCBA. Breathing Apparatus - Deals with the Maintenance and checks of SCBA Various IMO and Flag state Circulars dealing with maintenance and checks of various FFA equipment. Entry Into Enclosed Space - Approved SCBA equipment should be ready at the entrance SCBA and EEBD Responsibilities/ Duties - Extra SCBA cylinders. Deck / Accommodation / Cargo Space Fires - Use of the SCBA Rescue from Hold / Tank /Engine Room - Use of the SCBA SCBA Compressor - Maintenance and checks of SCBA Compressor MTM ANX1A Check Lists Proc D/109 Proc E/120 CL D/24 CL E / 008 CL E / 009 CL D/32A ~ 37 E/17 ~ 23 Guidelines On Planned Maintenance Schedules - Maintenance and checks of SCBA and the SCBA Compressor SCBA checks before use - Ensure these are ship specific Procedure for filling SCBA bottles - Ensure these are ship specific Master s S.E.P. Checklist - Point Number, condition and position of fireman outfit Weekly Test of SCBA Compressor Weekly Test of SCBA Compressor Checklist for Familiarization Of New Joining - Location, operation and use of SCBA CL 2013 Training Material TM 16 TM 23 TM 118 Miscellaneous SQ/MSG/086AS/14 Firefighting Tactics And Techniques USCG State Boarding Emergency Drill Guidance A Lecture On Ship Fires, Causes, Prevention And Extinguishment Amendments to SOLAS Regulations in force on 1st July Charging of breathing apparatus

2 Four basic assembly components: Backpack and harness Cylinder Regulator Face piece assembly Head Harness Head Straps Voice Emitter Nose Cone Head Straps Regulator Adapter Port

3 SCBA must only be used in an emergency situation and only by trained personnel Breathe normally Be comfortable Visually inspect equipment before use; Check condition of mask (face piece, head harness for cuts, scratches, missing buckles), backpack (straps & buckles for cuts, tears), cylinder (dents, gouges), hoses (cuts, cracks, bulges). After Visual inspection carry out the following checks before use; Check for full cylinder (minimum 90% - refer manufacturer s guidance) Check face piece Connect regulator to face piece, take 1-2 breaths Close cylinder valve and open by-pass to bleed air Check that low pressure alarm activates at proper pressure Close by-pass valve Perform the positive and negative tests before use. Report any obvious damage that would prevent safe and proper use of the SCBA

4 General safety conditions Use SCBA in accordance with manufacturer s recommendations Know the SCBA protection limits and safety features Ensure air bottles for all SCBA sets are interchangeable Know air supply duration Calculate a point of no return. Vacate space immediately if low air pressure alarm sounds Ensure proper face piece fit Follow basic safety guidelines Know your own physical limitations Before entering hazardous atmosphere, don and check unit for operation Always work in pairs Stay in contact with a wall, hose line, lifeline or partner Work to control breathing Protect the SCBA from damage Inspect and maintain SCBA, in accordance with SOLAS, manufacturer s and company requirements and should be always ready for use

5 Methods of Donning SCBA Over the head Open cylinder valve Hold back plate with both hands Lift SCBA over your head Slide SCBA down your back Tighten waist and shoulder straps Don face piece and check for seal Position protective hood / don helmet Connect regulator to the face piece

6 Coat Method Open cylinder valve Place dominant hand on opposite shoulder strap Lift SCBA and swing it over your dominant shoulder Slide other hand through corresponding shoulder strap Tighten waist and shoulder straps Don face piece and check for seal Position protective hood / don helmet Connect regulator to the face piece

7 Seat Mounted SCBA Sit in seat and place arms through shoulder straps When apparatus stops, release SCBA from mounting bracket Tighten waist and shoulder straps Open main cylinder valve Don face piece and check for seal Position protective hood / don helmet Connect regulator to the face piece

8 Donning the Face piece Grasp the harness with the thumbs through the straps from the inside, and spread the straps Rest your chin in the chin pocket at the bottom of the mask Fit the face piece to your face, bringing the straps or webbing over your head Pull the lower harness straps evenly and simultaneously to the rear to tighten them Pull the temple harness straps evenly and simultaneously to the rear to tighten them Check for proper seal. Pull the protective hood up so that it covers all bare skin Don your helmet and tighten the chin strap

9 Method of Removing the SCBA Remove the regulator from the face piece. Shut off the air supply valve Remove your helmet and pull your protective hood down around your neck Loosen the straps on your face piece Remove your face piece Release your waist strap Loosen the shoulder straps and remove the SCBA Bleed the air pressure from the regulator by opening the purge valve. Place the SCBA in a safe location

Course Firefighter I. Unit II Safety and Orientation

Course Firefighter I. Unit II Safety and Orientation Course Firefighter I Unit II Safety and Orientation Essential Question Why is proficiency donning and doffing SCBA important for firefighters? TEKS 130.299(c) (2)(C), (10)(B), (11)(A)(C)(E), (14)(A)(B)

More information

Donning Personal Protective Equipment

Donning Personal Protective Equipment Donning Personal Protective Equipment AFC & PSC Basic SCBA The ability to don personal protective clothing NFPA 1001, Standard for Fire Fighter Professional Qualifications 5.1.2, 5.3.1, 5.3.2, 5.3.3, 2013

More information

Performance Examination 4100 Sub JAC Handbook

Performance Examination 4100 Sub JAC Handbook TOPIC: CATEGORY: JAC PERFORMANCE EXAM 24 Extension Ladder POINTS POSSIBLE: 100 TIME ALLOWED: 6 Minutes BEHAVIORAL OBJECTIVE: Condition: Behavior: Standard: An engine with a MMR SCBA mounted in a breathing

More information

Checklist for care of Respirators

Checklist for care of Respirators Checklist for care of Respirators Inspect the respirator before and after each use and during cleaning. Inspect equipment designated for "emergency use" at least monthly, and after each use. Replace all

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE SCBA PAGE 1 OF 14 Maintenance Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE SCBA PAGE 1 OF 14 Maintenance Revised SCBA 10-07-16 PAGE 1 OF 14 The California Occupational Safety and Health Administration requires that: Respirators shall be regularly cleaned after each use or more often if necessary. Those used by more

More information

MMR Air Mask With. with Quick-Connect Hose

MMR Air Mask With. with Quick-Connect Hose MMR Air Mask With with Quick-Connect Hose Upgrade Kits P/N 10025120 Slide to Connect P/N 10050038 Slide to Connect w/ Solid Cover P/N 10038666 Push To Connect P/N 10050037 Push To Connect w/ Solid Cover

More information

Training. Level of training on the Scott 4.5 SCBA air pack must be completed in the order stated on the pages below.

Training. Level of training on the Scott 4.5 SCBA air pack must be completed in the order stated on the pages below. Training Employee training is an important part of the respiratory protection program and is essential for correct respirator use. The OSHA respiratory protection standard requires Rio Hondo Fire Academy

More information

( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel.

( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel. KIRBY MORGAN SUPERLITE DEEP SEA DIVING HELMET MODELS 17 A/B, 17C, 17K, & KM 37, KM 47, KM 57, KM 77 & KM 97 MONTHLY INSPECTION AND MAINTENANCE CHECKLIST Appendix A2.2 (10-2-2016 SC) This inspection is

More information

DRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

DRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 12-17-03 THIS INSPECTION AND MAINTENANCE MUST BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING

More information

Product Information News

Product Information News Product Information News MMR SECOND STAGE REGULATOR VALVE CORE MSA has changed its recommended rebuilding of the MMR Second Stage Regulator s bypass sleeve assembly during the annual inspection. Based

More information

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional JPR Verification Sheet is to be used in conjunction with the Alabama Fire

More information

Alabama Smoke Diver Policies

Alabama Smoke Diver Policies Policies Class will begin at 8:00 a.m. Tardiness will not be tolerated! First instance of Tardiness will result in positive physical reinforcement (PT). If a candidate has a second tardy, he or she will

More information

PPE Refresher Using your SCBA

PPE Refresher Using your SCBA PPE Refresher Using your SCBA Time Requirement: 2-3 hours total (depending on number of participants) Number of Instructors: Minimum of 2 Materials Student materials (participant guide, worksheets) Whiteboard,

More information

The Airfield Volunteer Fire Service

The Airfield Volunteer Fire Service The Airfield Volunteer Fire Service Breathing Apparatus Deployment Policy Policy Number: P23 Origin: KP Date: 25/06/2015 1 Contents Breathing Apparatus Deployment Policy Page Contents 3 Introduction 3

More information

5.3.2 Respond to an incident, correctly mounting and dismounting an apparatus. FFI -1 Revised 6/9/ Don appropriate PPE.

5.3.2 Respond to an incident, correctly mounting and dismounting an apparatus. FFI -1 Revised 6/9/ Don appropriate PPE. 5.3.2 Respond to an incident, correctly mounting and dismounting an apparatus. FFI -1 STANDARD: 5.3.2 TASK: Safely mount and dismount fire department apparatus PERFORMANCE OUTCOME: The candidate will correctly

More information

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 INSTRUCTION MANUAL FOR THE EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 Manual Number: NH24053 Revision: A, ECN 3590 December 14, 2015 Page 1 of 13 CONTENTS PAGE INTRODUCTION... 3 GENERAL

More information

031-COM-1004 Protect Yourself From Chemical And Biological (CB) Contamination Using Your Assigned Protective Mask Status: Approved

031-COM-1004 Protect Yourself From Chemical And Biological (CB) Contamination Using Your Assigned Protective Mask Status: Approved Report Date: 09 May 2017 031-COM-1004 Protect Yourself From Chemical And Biological (CB) Contamination Using Your Assigned Protective Mask Status: Approved Distribution Restriction: Approved for public

More information

Preparation OVERVIEW: Protective Clothing and Equipment Safety Protective clothing Self-contained breathing apparatus

Preparation OVERVIEW: Protective Clothing and Equipment Safety Protective clothing Self-contained breathing apparatus INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 2 TOPIC: PROTECTIVE CLOTHING AND EQUIPMENT LEVEL OF INSTRUCTION: 3.0 TIMRE REQUIRED: 3 HOURS MATERIALS: Personal Protective Clothing Self-Contained

More information

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001 INSTRUCTION MANUAL FOR EBA 6.5 60 MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001 Page 1 of 20 CONTENTS PAGE INTRODUCTION 3 GENERAL INFORMATION..3

More information

CIRCULAR LETTER. Subject: Riyadh MoU - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry

CIRCULAR LETTER. Subject: Riyadh MoU - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry CIRCULAR LETTER Piraeus, 28 August 2017 Subject: Riyadh MoU - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry The Riyadh MoU on Port State Control (PSC) have announced

More information

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage 1. Purpose This Work Instruction is to be used for the proper inspection, cleaning, maintenance, repair and storage of respirators. 2. Procedure 2.1. General All respirators used in routine situations

More information

Guidance on the maintenance and inspection of fixed CO 2 fire-extinguishing systems

Guidance on the maintenance and inspection of fixed CO 2 fire-extinguishing systems Translation. Only the Danish document has legal validity. Guidance no. 9514 of 9 July 2014 issued by the Danish Maritime Authority Guidance on the maintenance and inspection of fixed CO 2 fire-extinguishing

More information

CIRCULAR LETTER. Subject: Paris and Tokyo MoUs - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry

CIRCULAR LETTER. Subject: Paris and Tokyo MoUs - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry CIRCULAR LETTER Piraeus, 28 August 2015 Subject: Paris and Tokyo MoUs - Concentrated Inspection Campaign (CIC) on Crew Familiarization for Enclosed Space Entry The Paris and Tokyo MoUs on Port State Control

More information

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 01-31-17 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING

More information

KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A

KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A2.2 08-01-17 This inspection is the minimum recommended maintenance and should be performed at least ONCE A MONTH with Mask(s) in continuous use (used

More information

TABLE OF CONTENTS PART 11 - FIREFIGHTING

TABLE OF CONTENTS PART 11 - FIREFIGHTING TABLE OF CONTENTS PART 11 - FIREFIGHTING Page DEFINITIONS...11-1 APPLICATION...11-1 GENERAL REQUIREMENTS...11-2 PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT FOR FIREFIGHTERS...11-2 SELF-CONTAINED BREATHING

More information

U.S. Patent No. 7,922,246. Patents Pending

U.S. Patent No. 7,922,246. Patents Pending U.S. Patent No. 7,922,246 Patents Pending 2 Table of Contents Page General Information... 3 Warnings and Cautions... 4 Tools... 6 SmartDock Parts... 6 Initial Set-Up and Adjustment... 7 Select Valve Retaining

More information

2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION

2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION 2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION Friday, August 17, 2018 Dalton, Georgia OFFICIAL RULES & REGULATIONS Please review the following rules and regulations for the Georgia Fire

More information

SECRETARY OF THE AIR FORCE 1 JUNE 2000 LOADMASTER PROCEDURES

SECRETARY OF THE AIR FORCE 1 JUNE 2000 LOADMASTER PROCEDURES BY ORDER OF THE AFI 11-2C-141V3 CL-2 SECRETARY OF THE AIR FORCE 1 JUNE 2000 LOADMASTER PROCEDURES Flying Operations LOADMASTER PASSENGER BRIEFINGS This checklist establishes procedures for the operation

More information

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE SCBA MAINTENANCE SCOPE Stoney Point Fire Department Self-contained breathing apparatus provides respiratory protection under conditions of oxygen deficiency or in concentrations of toxic gases immediately

More information

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM SELF CONTAINED BREATHING APPARATUS

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM SELF CONTAINED BREATHING APPARATUS LOS ANGELES COUNTY FIRE DEPARTMENT SELF CONTAINED BREATHING APPARATUS 14 L0S ANGELES COUNTY FIRE DEPARTMENT 15 SELF CONTAINED BREATHING APPARATUS 1. General Information BREATHING APPARATUS SURVIVAIR PANTHER

More information

RESOLUTION A.855(20) adopted on 27 November 1997 STANDARDS FOR ON-BOARD HELICOPTER FACILITIES

RESOLUTION A.855(20) adopted on 27 November 1997 STANDARDS FOR ON-BOARD HELICOPTER FACILITIES A 20/Res.855 17 December 1997 Original: ENGLISH ASSEMBLY 20th session Agenda item 9 RESOLUTION A.855(20) adopted on 27 November 1997 THE ASSEMBLY, STANDARDS FOR ON-BOARD HELICOPTER FACILITIES RECALLING

More information

Button style shirt and firefighting gloves are not required. (This will be a requirement in 2019.)

Button style shirt and firefighting gloves are not required. (This will be a requirement in 2019.) Firefighting (FF) Public Safety Skilled and Technical Sciences Contests Contest Information State Qualifying Exam: Yes National Contest: Yes Participation: Individual Update April 2, 2018 Contest Description

More information

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL 1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL

More information

Air Mask Low/High Pressure

Air Mask Low/High Pressure Air Mask Low/High Pressure USERS MAINTENANCE INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS AIR MASK. This

More information

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by INSTRUCTION MANUAL EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H Mat. No 10020357 / 04 Safety by EEC DECLARATION OF CONFORMITY ISSUED IN RESPECT OF THE DIRECTIVE 96/98

More information

1.4 Lift up one of the distressed members legs and place it on your shoulder.

1.4 Lift up one of the distressed members legs and place it on your shoulder. MANAGING MEMBERS IN DISTRESS CHAPTER 3, ADDENDUM 1 November 1, 2011 1. THROUGH THE LEG METHOD 1.1 Locate the waist strap of the SCBA. 1.2 Fully loosen both halves of the waist belt. 1.3 Unbuckle the waist

More information

Combination Breathing Apparatus

Combination Breathing Apparatus and Combination Breathing Apparatus ULTRAVUE FACEPIECE TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064385 Doc. 10064385 ULTRAVUE FACEPIECE COMPONENTS Item Part No. Description 800509

More information

Chapter 2 Operating Instructions

Chapter 2 Operating Instructions Chapter 2 Operating Instructions 2.1 Introduction This section provides the manufacturer s recommendations on how to use the three EXO Full-face Masks. The use of these diving masks will vary with the

More information

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask Page: 1 of 15 Operating instruction APR SR 200 full face mask Page: 2 of 15 General information The SR 200 full face mask can be used in two configurations: Together with filters/cartridges from the Sundström

More information

Protective Envelope and Foam

Protective Envelope and Foam Note Taking Guide Protective Envelope and Foam Maryland Fire and Rescue Institute University of Maryland Steven T. Edwards Fall 2011 Copyright 2011 by the Maryland Fire and Rescue Institute. All rights

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

Installation Manual. Version 12-10

Installation Manual. Version 12-10 Installation Manual The products and parts shown herein are to be installed and used adjusted in accordance with these instructions. Any deviation by the buyer, installer, or user from these instructions

More information

Operating Manual. PremAire Combination. Self-Contained Breathing Apparatus for Escape. Order No /01. MSAsafety.com

Operating Manual. PremAire Combination. Self-Contained Breathing Apparatus for Escape. Order No /01. MSAsafety.com Operating Manual Self-Contained Breathing Apparatus for Escape Order No. 10154060/01 MSAsafety.com MSA AUER GmbH Thiemannstrasse 1 D-12059 Berlin Germany MSA AUER GmbH. All rights reserved Contents Contents

More information

Chapter 6 Test. Directions: Write the correct letter on the blank before each question.

Chapter 6 Test. Directions: Write the correct letter on the blank before each question. Chapter 6 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe the purpose of personal protective equipment. Objective 2: Describe characteristics

More information

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS ExtendAire TM II Intermediate Pressure Accessory Kit USER INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS

More information

To: Vessel Owners, Managers, Masters, Officers, Deputy Registrars, Surveyors and Other Interested Parties

To: Vessel Owners, Managers, Masters, Officers, Deputy Registrars, Surveyors and Other Interested Parties Circular 109 / 2015 To: Vessel Owners, Managers, Masters, Officers, Deputy Registrars, Surveyors and Other Interested Parties Subject: Paris, Tokyo MoU Concentrated Inspection Campaign Enclosed Spaces

More information

CITY OF VANCOUVER ADMINISTRATIVE REPORT

CITY OF VANCOUVER ADMINISTRATIVE REPORT A5 CITY OF VANCOUVER ADMINISTRATIVE REPORT Report Date: July 03, 2008 Author: Daniel Hilton Phone No.: 604.665.6082 RTS No.: 07407 VanRIMS No.: 08-2000-20 Meeting Date: July 22, 2008 TO: FROM: SUBJECT:

More information

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the

More information

About us. We supply Industrial gases, calibration gases, Medical gas Fireman protection and equipment

About us. We supply Industrial gases, calibration gases, Medical gas Fireman protection and equipment About us AIRGAS TECHNOLOGY Sdn Bhd, We specialize in supply of all range of industrial gases, gas cylinder, valve, regulator, hoses, personal protection equipment s for fireman and industrial, firefighting

More information

RAPID INTERVENTION CREW (RIC) Bag

RAPID INTERVENTION CREW (RIC) Bag RAPID INTERVENTION CREW (RIC) Bag Objectives Identify the components of the Rapid Intervention Crew (RIC) Bag. Identify the apparatus that will carry the RIC bags. Demonstrate each of the RIC Bag rescue

More information

Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technic

Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technic Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technical Information No. TEC-0869 Date 14 October 2011 The

More information

Guidance on Enclosed Space Entry and Rescue

Guidance on Enclosed Space Entry and Rescue Guidance on Enclosed Space Entry and Rescue Preparation for the 2015 Concentrated Inspection Campaign (CIC) by the Paris MoU and Tokyo MoU Crew Familiarization for Enclosed Space Entry The Paris MoU and

More information

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01 Fit Testing Once all three steps are complete, the mask must be fit tested. This is done using the TSI Portacount Test System Before either of the tests begin, the mask must be set up properly. Fit and

More information

2017 GSFA / GAFC FIREFIGHTER S COMPETITION

2017 GSFA / GAFC FIREFIGHTER S COMPETITION 2017 GSFA / GAFC FIREFIGHTER S COMPETITION Friday, August 25, 2017 400 Foundry Pavilion Athens, Georgia (Located behind the Classic Center) OFFICIAL RULES & REGULATIONS Please review the following rules

More information

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks Operating Manual 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask AirElite - Full Face Masks Order No.: 10065505/05 MSA AUER GmbH D-12059 Berlin Thiemannstraße

More information

Operating Manual. PremAire Escape. Self-Contained Compressed Air Breathing Apparatus for Escape. Order No. D /00. MSAsafety.

Operating Manual. PremAire Escape. Self-Contained Compressed Air Breathing Apparatus for Escape. Order No. D /00. MSAsafety. Operating Manual Self-Contained Compressed Air Breathing Apparatus for Escape Order No. D4088228/00 MSAsafety.com MSA AUER GmbH Thiemannstrasse 1 D-12059 Berlin Germany MSA AUER GmbH. All rights reserved

More information

User Information Sheet 013

User Information Sheet 013 User Information Sheet 013 Formerly LPGA Technical Memorandum NO.81 Issue 2 September 2007 ACME threaded couplings 1 INTRODUCTION ACME threaded couplings/end fittings are widely used for LPG transfer operations

More information

PINE HILL FIRE DEPARTMENT

PINE HILL FIRE DEPARTMENT PINE HILL FIRE DEPARTMENT STANDARD OPERATIONAL GUIDELINES Operations-22 Subject: PPE (Turnout Gear) Effective Date: 3/1/2008 Revised 11/11/2014 Pages: 1 of 5 The environments in which firefighters perform

More information

SIDE 16 Sidemount System User Manual

SIDE 16 Sidemount System User Manual SIDE 16 Sidemount System User Manual Version 1.1, April 15, 2014 Disclaimer This document is proprietary to Scubatech Sp. z o. o. ("Scubatech") and no ownership rights are hereby transferred. No part of

More information

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL

More information

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL

More information

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE Government of Bermuda Department of Maritime Administration 2015 027 BERMUDA SHIPPING NOTICE Maintenance and Inspection of Fixed Carbon Dioxide Fire Extinguishing Systems Ref: SOLAS 74/88 as amended, Regulation

More information

REQUEST FOR PROPOSAL RFP FD SCBA. Closing Time: August 23rd, 2018 at 2:00pm Local time

REQUEST FOR PROPOSAL RFP FD SCBA. Closing Time: August 23rd, 2018 at 2:00pm Local time REQUEST FOR PROPOSAL RFP2018-001FD SCBA Closing Time: August 23rd, 2018 at 2:00pm Local time Village of Sundridge 110 Main Street, PO Box 129 Sundridge, ON P0A 1Z0 Phone: 705-384-5316 Fax: 705-384-7874

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

SAR/SCBA SS600-AN-MMA-010

SAR/SCBA SS600-AN-MMA-010 SAR/SCBA SS600-AN-MMA-010 Chapter 2 CHAPTER 2 OPERATION 2.1 INTRODUCTION. Chapter 2 provides a description of the controls, indicators, and operating procedures for the Primary Air Supply Pack (PASP),

More information

Florida Public Service Association, Inc.

Florida Public Service Association, Inc. Revised 07/2017 Purpose: To encourage public service students to develop the skills to don firefighter protective gear. Description of Event: Competitors will simulate being awakened and prepare for a

More information

ST53SD. Self Contained Breathing Apparatus. User Manual

ST53SD. Self Contained Breathing Apparatus. User Manual Self Contained Breathing Apparatus User Manual User Manual for the (Short Duration) Self Contained Breathing Apparatus WARNING Disassembly of the components beyond the procedures described herein shall

More information

BREATHE SAFELY: The Proper Use of Respiratory Protection

BREATHE SAFELY: The Proper Use of Respiratory Protection BREATHE SAFELY: The Proper Use of Respiratory Protection This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of

More information

BMR Low/High Pressure USERS MAINTENANCE INSTRUCTIONS

BMR Low/High Pressure USERS MAINTENANCE INSTRUCTIONS BMR Low/High Pressure USERS MAINTENANCE INSTRUCTIONS THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THE PRODUCT. Like any complex piece

More information

City of Minot Specifications SCBA

City of Minot Specifications SCBA January 2018 City of Minot Specifications SCBA The unit described under these specifications shall be the manufacturer s latest SCBA and meet the following minimum specifications. Any deviations from the

More information

APPENDIX D. On-Site Fatality Investigation Checklists. Steven M. Barsky Marine Marketing & Consulting 2419 E. Harbor Blvd. #149 Ventura, CA USA

APPENDIX D. On-Site Fatality Investigation Checklists. Steven M. Barsky Marine Marketing & Consulting 2419 E. Harbor Blvd. #149 Ventura, CA USA APPENDIX D On-Site Fatality Investigation Checklists Steven M. Barsky Marine Marketing & Consulting 2419 E. Harbor Blvd. #149 Ventura, CA 93001 USA Diving Accident Equipment Inspection Victim s name: Location

More information

Ocean County Fire Academy. Fall 2018 Course Listings

Ocean County Fire Academy. Fall 2018 Course Listings Ocean County Fire Academy Fall 2018 Course Listings Fall 2018 Class Schedule September Stand Pipe Operations September 19 Stand pipes are being found more often in many types of buildings and special locations.

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

Westbrook Fire & Rescue Department Standard Operating Procedure

Westbrook Fire & Rescue Department Standard Operating Procedure 2017-103 Respiratory Protection Program Westbrook Fire & Rescue Department Standard Operating Procedure Section: Administrative TOPIC: Respiratory Protection Program NUMBER: 2017-103 ISSUE DATE: December

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

GSFA FIREFIGHTER S COMPETITION 2012 OFFICIAL RULES & REGULATIONS

GSFA FIREFIGHTER S COMPETITION 2012 OFFICIAL RULES & REGULATIONS GSFA FIREFIGHTER S COMPETITION 2012 OFFICIAL RULES & REGULATIONS 1530 HOURS RAPID DRESS QUALIFYING ROUND 1700 HOURS COACHES MEETING 1800 HOURS FIREFIGHTER S COMPETITION BEGINS RULES & REGULATIONS - RAPID

More information

STANDARD OPERATING GUIDELINE

STANDARD OPERATING GUIDELINE DATE ISSUED: Purpose The purpose of this guideline is to establish procedures for when it becomes necessary to provide emergency assistance to a firefighter(s) that is/are lost, incapacitated or unable

More information

Sperian Warrior SCBA

Sperian Warrior SCBA Sperian Warrior SCBA Air Cylinder Carbon fiber wrapped aluminum bottle with epoxy overlay. Hydrostatically tested Every 5 years When damaged Suspected to be unsafe (heat exposure, dropped, etc.) Valve

More information

Based on NFPA 1081: Standard for Industrial Fire Brigade Member Qualifications.

Based on NFPA 1081: Standard for Industrial Fire Brigade Member Qualifications. Based on NFPA 1081: Standard for Industrial Fire Brigade Member Qualifications. Donning Personal Protective Clothing 2007 Edition, NFPA 1081 Chapter 6.2.1b, 7.1.2.1b AFC & PSC Industrial Fire Brigade Skill

More information

TESTING SKILLS SAFETY

TESTING SKILLS SAFETY SAFETY #1 Techniques for Actions When Trapped or Disoriented Subject: Fireground Operations Section 101 NFPA 1001 5.3.5 Firefighter I OBJECTIVE Exit a hazardous area as a team, given vision obscured conditions,

More information

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell Separating the Side Block Assembly from the Helmet Shell Contents SSB-1 SSB-3 SSB-5 SSB-5 SSB-7 1.1 Separating the Side Block Assembly from the Helmet Shell 1.2 Side Block Assembly Replacement 1.3 Defogger

More information

Commonwealth of Dominica. Office of the Maritime Administrator

Commonwealth of Dominica. Office of the Maritime Administrator Commonwealth of Dominica Office of the Maritime Administrator TO: ALL SHIPOWNERS, OPERATORS, MASTERS, AND SEAFARERS OF MERCHANT SHIPS, AND RECOGNIZED ORGANIZATIONS SUBJECT: REFERENCE: EMERGENCY TRAINING

More information

FRS 105. Firefighters Intermediate Skills II. 45 clock hours 3 credit hours

FRS 105. Firefighters Intermediate Skills II. 45 clock hours 3 credit hours FRS 105 Firefighters Intermediate Skills II 45 clock hours 3 credit hours Course Title Lecture/Skill Total Fractional FRS 1051 Fire Department Organization II 4 0 4 0.3 FRS 1052 Fire Behavior II 6 0 6

More information

Operating Manual. Models PAK-4 & PAK-4R Manual No. PAK002 (Rev 6 February 1999)

Operating Manual. Models PAK-4 & PAK-4R Manual No. PAK002 (Rev 6 February 1999) Models PAK-4 & PAK-4R Manual No. PAK002 (Rev 6 February 1999) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100

More information

Standbys. (Owner: Risk Management Section Supervisor)

Standbys. (Owner: Risk Management Section Supervisor) BTCP/BTRF Standbys (Owner: Risk Management Section Supervisor) Site Safety Standard 5500 Introduction Scope The purpose of this standard is to specify detailed roles and responsibilities of Standby personnel

More information

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 9-22-15 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED

More information

NIOSH Task Number 18388

NIOSH Task Number 18388 National Personal Protective Technology Laboratory Technology Evaluation Branch Certified Product Investigation Program Report of Self-Contained Breathing Apparatus Second Stage Regulators Submitted by

More information

PRE-JUMP FOR FORT BRAGG UNITS OCTOBER 2016

PRE-JUMP FOR FORT BRAGG UNITS OCTOBER 2016 The first items I will discuss are the five points of performance. The first point of performance is proper exit, check body position, and count. Jumpers hit it. Upon exiting the aircraft, snap into a

More information

Dive Rescue International Terms & Conditions

Dive Rescue International Terms & Conditions Dive Rescue International Terms & Conditions Contact Us: Phone: (800) 248-3483 Fax: (970) 482-0893 Website: www.diverescueintl.com E-mail: sales@diverescueintl.com Mail: 201 North Link Lane Fort Collins,

More information

REVISED ATTACHMENT 2 BID PRICING FORM

REVISED ATTACHMENT 2 BID PRICING FORM REVISED ATTACHMENT 2 BID PRICING FORM 1. The low price determination shall be the base bid amount as indicated in Row 8. 2. Do not include sales tax in your bid. Prior to award of contract, the City will

More information

TABLE OF CONTENTS PART 2 - CONFINED SPACES

TABLE OF CONTENTS PART 2 - CONFINED SPACES May 11, 2006 TABLE OF CONTENTS PART 2 - CONFINED SPACES Page DEFINITIONS... 2-1 GENERAL... 2-2 RESPONSIBILITIES... 2-2 HAZARD ASSESSMENT AND WORK PROCEDURES... 2-3 IDENTIFICATION AND ENTRY PERMITS... 2-3

More information

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES Page 1 o Page 1 of 12 RESPIRATORY PROTECTION POLICY Issued by: Fire Chief Policy No. 26-06AM Authority: Code Section 21-2.(d)(4) Effective Date: April 15, 2005 SUMMARY: ADDRESS: STAFF: BACKGROUND: This

More information

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL SAFE -14 Page 1 of 8 U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL FUNCTION Safety TOPIC Hotwork Permit Program OBJECTIVE(S): GENERAL POLICY: To provide a work atmosphere that is conducive to

More information

r (bar) Air Volume(L) Approval Service Life TPED 15

r (bar) Air Volume(L) Approval Service Life TPED 15 INSTRUCTION MANUAL FOR THE DEVICE Emergency Escape Breathing Device JIANGSU HUAYAN MARINE EQUIPMENT CO., LTD. 1. Introduction 1.1 Preface Compressed air emergency escape breathing apparatus TH15B (shorten

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 4 Guidelines for Equipment on Fire Fighting Ships Edition 2008 The following Guidelines come into

More information

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION 1 MFRI Drill of the Month INSTRUCTOR GUIDE TOPIC: EVALUATING FIREFIGHTER PROFICIENCY LEVEL OF INSTRUCTION: TIME REQUIRED: SIX HOURS MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

More information

Tremont Volunteer Fire Department Respiratory Protection Plan

Tremont Volunteer Fire Department Respiratory Protection Plan Tremont Volunteer Fire Department Respiratory Protection Plan PURPOSE: This respiratory protection program is designed to provide a standard operating policy for the Tremont Volunteer Fire Department (TVFD).

More information

Author in a 7mm Semi-Dry Suit

Author in a 7mm Semi-Dry Suit Diving a Drysuit Mike Ault, Copyright: 5 July, 2006 I am sure almost everyone has heard of a wetsuit. A wetsuit is basically a skintight neoprene rubber suit that divers wear to shield them from heat loss.

More information

Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung. U.S. Patent No. 7,922,246. Patent Pending

Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung. U.S. Patent No. 7,922,246. Patent Pending Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung For International Markets U.S. Patent No. 7,922,246 Patent Pending 2 Table of Contents Page General Information... 3

More information