FLOW. Product Data Sheet Metal Tube VA Gas or Liquid. DS1220 Issue 5: 06. Page 1 of 4. DS1220/1221

Size: px
Start display at page:

Download "FLOW. Product Data Sheet Metal Tube VA Gas or Liquid. DS1220 Issue 5: 06. Page 1 of 4. DS1220/1221"

Transcription

1 FLOW Product Data Sheet Metal Tube VA Gas or Liquid DS1220/1221 METAL TUBE VA FLOWMETER TYPE GMT GMT metal tube flowmeters are variable area meters of totally welded stainless steel construction. Liquid or Gas flowing up the tapered flowtube lifts the float to an equilibrium position, dependent on flow rate, and a magnetically coupled pointer indicates this flow on an external scale. The large meter indication is easily visible at a distance, with the pointer moving over a 150 o scale. Each scale is produced specifically for the fluid involved and process conditions expected: several flow ranges are available for meters of each standard line size. All gas flow meters are supplied with an integral piston damper to smooth out flow pulsations. Installation is simple, in a vertical section of flow line: meters can be supplied with DIN, ANSI or other standard flanges, or BSP or NPT screwed connections. The robust construction with no glands or seals to leak means the meters are suitable for high pressure applications, or extremes of temperature. The standard GMT is totally self contained and needs no external power. Alternative materials are available to special order - for example Hastelloy or Monel wetted parts, PTFE lined versions. For lower cost, Brass or Stainless steel bodied meters ` - 2 in size are available with screwed connections. The indicator can be provided with one or two flow alarm sensors, adjustable over the meter operating range. Full electronic transmission and totalisation is also available, using the VAMPIRE electronic module. Metal tube meters are ideal for arduous industrial service as an alternative to large glass tube flowmeters. They have particular advantages, where fluids are opaque or staining, or to provide higher safety and security for dangerous or toxic fluids. FEATURES 15, 25, 50, 75 and 100mm 1/2" 1" 2" 3" & 4" line sizes No power required Clearly visible meter Scaled for process fluids Easy installation - flanged or screwed No glands or seals Robust, simple construction Pulsation damper on gas meter PRINCIPLE OF OPERATION The metering element consists of a precision machined tapered tube and a float. The height to which the float rises in taper is determined by the gap at which upward flow force and float weight are balanced. A permanent magnet encapsulated within the stainless steel float drives the external magnetically coupled pointer. Float movement is related to flow rate, and the indicator scale is marked in the correct units of flow for the process conditions. The standard unit requires no electrical power. Because the measuring element is a sharp edged disc, the meter is relatively insensitive to viscosity changes in the fluid, and to pipe bends in the external pipework. The only moving part in the flow is the float, which is retained in place by float guides at either end of the meter. LICO Electronics GmbH, A Kledering office@lico.at h.miksch@lico.at Tel DS1220 Issue 5: 06. Page 1 of 4

2 SPECIFICATION Flanged flow tube Flanges Line Sizes Pressure Screwed flow tube Connections Pressure Float Pulsation damper 316 Stainless steel, all welded construction DIN PN16 (BS4504) or ANSI 150 standard. Other flanges to order 15, 25, 50, 80, 100mm To flange rating, 100 bar max Brass or 316 Stainless Steel `,1 or 2 BSPP or NPT standard 75 bar max GMTB (Brass) 100 bar max GMTS (Stainless) 316 Stainless steel PVC float on low pressure drop option units All gas flowmeters have a dashpot damper built-in Indicator housing Protection Scale length Scales Turndown Typically 10:1 Accuracy ±2% FSD Hysteresis Fluid Temperature Response time Flow direction Surface Finish Polyester coated aluminium alloy,with UV stable polycarbonate face IP65 Typically 100mm, 150 degrees Produced to order to suit process fluid and conditions. Air and water flow ranges quoted opposite ±0.5% FSD 200 o C max (higher to special order) Less than 0.5 secs Vertically upwards 1.6µm ORDER CODE Model Number GMT G - (Example is 2 GMT,Flanged PN16, ranged m3/h Air) GMT family Model Type No digit Flanged stainless B Brass body screwed S Stainless body screwed Fluid G = Gas, max 2" L = Liquid, max 4" Digit to identify specified Flow Range (See Table on next page) Electronic outputs No digit standard indicator A Single flow alarm AA Dual flow alarm XA AC powered transmitter XD CENELEC Approved Looped powered transmitter Flow pipe size 1 15mm or ` 2 25mm or mm or mm or mm or 4 Note: Not all options available together. End Connections 1 Flanged DIN PN16 2 Flanged ANSI 150lb 3 Flanged DIN PN40 4 Flanged ANSI 300lb 5 Screwed BSPP female 6 Screwed NPT female TO ORDER Specify process conditions at measurement point (fluid type, density/sg, viscosity, temperature, and pressure) plus operational flow range and units LICO Electronics GmbH, A Kledering office@lico.at h.miksch@lico.at Tel DS1220 Issue 5: Page 2 of 4

3 FLOW RANGES STANDARD UNITS Size/Model Flow Water(20oC) Air at ATP Max DP Flow Air (ATP) Natural Max DP Digit (m3/hr) (mbar) Digit m3/hr Gas (ATP) (mbar) (m3/hr) 15mm (GMT1) l/h A l/h B l/h C l/h D mm (GMT2) m 3 /h A m 3 /h B m 3 /h C m 3 /h D m 3 /h m 3 /h mm (GMT3) m 3 /h m 3 /h m 3 /h m 3 /h mm (GMT4) m 3 /h N/A m 3 /h N/A m 3 /h N/A mm (GMT5) m 3 /h N/A 440 LOW DP GAS UNITS NOTES 1. Units will be scaled and calibrated for customers specific process conditions, which may differ from those tabulated (See overleaf ). 2. Typical maximum liquid viscosity is 50cP, lower for the highest flow ranges and small sizes. 3. Screwed 1 units are not available for Flow Digit 6. OPTIONS 1. Oxygen Service Standard units cleaned to required specification. Special units available with Brass internal construction 2. Alarm Output Sensor NAMUR type SJ2-N to DIN Approval EEx ia IIC T6 Single or dual alarms can be fitted to a GMT flowmeter: the sensor requires a suitable control room interface. Please ask for suppliers separate data sheet. 3. Electrical Output All GMT flow tube sensors can be fitted with VAMPIRE mirco based electronic transmitter and flow indicator units. Please see Data Sheet DS Alternative body Materials/Designs The PTFE lined meter option is used for corrosive chemicals. Float, guides and flange raised face are PFTE or ceramic. The hygienic option with crevice free construction is polished to µm finish and fitted with Triclover connections. In addition Triclover, RJT, DIN 118, SMS connections can be fitted to Std flanged body. Refer to DS1221 for Screwed GMT datasheet LICO Electronics GmbH, A Kledering office@lico.at h.miksch@lico.at Tel DS1220 Issue 5: Page 3 of 4

4 ALTERNATIVE FLUIDS Approximate flow ranges for alternative process fluids and gas pressures can be calculated using the following formulae. For a full calculation please contact our Sales Team. 1. Gases at pressure or temperature For Air or gas flows where the pressure in the line on the discharge side of the flowmeter is not atmospheric (1.013 bar), multiply the flow range at ATP quoted in the table by a factor calculated as the square root of the pressure (in bar abs) divided by Air flow in process = For temperature changes P (abs) x Air flow in table Air flow at T = 293 T (K) x Air flow in table 2. Alternative gases For gases other than Air, find the Relative Density (RD) of the gas compared to Air, and divide the flow range quoted for Air in the table by the square root of the Relative Density. Gas flow range = Air flow in table x Examples of RD figures for some gases are as follows: Acetylene Carbon dioxide Nitrogen Argon Hydrogen Oxygen Butane Natural Glass Propane RD 3. Alternative Liquids For non vicious liquids other than water, the main correction arises from the density/sg. For the process liquid flow range multiply the Water flow range from the table by a factor D from below. SG D For a liquid of 1.2 SG, the GMT411L flowmeter would have a full scale flow of 25 x 0.9 ie. 22 m3/hr: the scale would be drawn 2-23 typically. Actual scale used would be rounded up, for example 2-23 in this case. B D E DIMENSIONS C 126 A 106 INSTALLATION C F (AF) Pipe Bore A BC 1. All VA meters are designed for vertical installations, with flow upwards. It is necessary to have 5 straight pipe diameters upstream and 2 straight pipe diameters downstream. Bends in two planes should be avoided. 2. The upstream and downstream pipe bores should suit the normal size of the instrument, if possible. 3. Ensure that no ferromagnetic material is situated within 100mm of the indicator. 4. Before installing the meter, the pipeline should be flushed to remove any foreign matter, or swarf, likely to collect on the float unit and magnet. 5. For ultimate protection a filter should be fitted upstream of the meter to remove large particles. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.. D EF N/A N/A N/A N/A LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria office@lico.at Tel DS1220 Issue 5: Page 4 of 4

5 FLOW Product Data Sheet Platon Screwed Metal Tube VA Flowmeter DS1221 PLATON GMTB & S SERIES Part of the Platon GMT Variable Area flowmeter family, models GMTB and GMTS are brass or Stainless Steel tube flowmeters with female screwed connections. With 1/2, 1 and 2 BSP/NPT threaded fittings standard, the meters are ideal for arduous industrial service as an alternative to large glass tube flowmeters. They have particular advantages for gas or liquid flow measurement at high pressures and temperatures, where the fluids are opaque or dark coloured or to provide higher operational security for dangerous or toxic materials. The VA meter principle used in the Platon GMT flowmeter measures the position of a float in a precision-machined tapered tube. The float rises with the flow up the taper until the upthrust from the flow balances with the weight of the float. A magnet, electron beam welded into the float casing, drives the external meter indication over a 100mm scale typically displaying a 10:1 flow range. FEATURES Economic construction BSP/NPT screwed end fittings Brass or Stainless Steel Wide flow ranges Sizes 15, 25, 50mm. 1/2, 1, 2 bore Integral damping on gas flow lines Local indication Calibration for wide range of gases and liquids Optional electronic outputs Options available on the GMTB/GMTS include (GMTA) flow alarm outputs for high or low adjustable set points and electronic 4-20mA flow transmitter (GMTX) outputs. All of these are available with CENELEC intrinsically safe approval. For low-pressure Natural gas flow measurement, models are available with minimal line pressure loss. Special versions are available for Oxygen service. All units are available calibrated for the specific line conditions or fluid involved. LICO Electronics GmbH, A Kledering office@lico.at h.miksch@lico.at Tel DS1221 Page 1 of 2

6 SPECIFICATION Body Materials GMTB: Brass GMTS: 316 Stainless Steel Float & Float Guides 316 Stainless Steel Indicator Housing Aluminium alloy LM25M polyester coated, weather-proofed to IP65 Connections BSP or NPT female thread sizes 1/2,1,2 Scale Length 100mm, 150 degrees. Air or water. Standard scales. Custom scales available to order Turndown Typically 10:1 Accuracy ±2% FSD Hysteresis Less than 0.5% Pressure GMTB: 75 bar GMTS: 100 bar Temperature Max 200 o C Min -50 o C (Based on Ambient of 20o C) Dashpot Damper To smooth out flow fluctuations and noise on gas flows, a dashpot damper is built in. This is suitable for clean gases where particulate matter is less than 50 microns. Natural Gas Std variants available for low pressure drop applications, using PVC float assemblies See catalogue for full details. Specify line pressure and flow range when enquirying. Approvals CRN (Contact sales for details) OPTIONS AVAILABLE Calibration for different liquids or gases or for nonstandard operating process conditions Flow alarm outputs (GMTA) or analogue 4-20mA (GMTX, DS1225) outputs, with CENELEC approval if required Higher pressure or temperature models Alternative materials Flanged and hygienic connections Hygienically polished PTFE lined flanged units Special models for Oxygen service, including all brass designs. Stainless Steel flanged versions of the GMT flowmeter are described in Roxspur data DS1220 H I G J E INSTALLATION NOTES 1. The instrument should be installed vertically in the pipework with the direction of flow vertically upwards. A F 2. Ensure that any ferromagnetic material is clear of the body and indicator case by 100mm minimum. 3. The upstream and downstream pipe bores should be the same nominal size as the instrument. Straight pipe lengths of 5 diameters upstream and 2 diameters downstream should be provided if possible. 4. Before the meter is installed, the pipeline should be checked, cleaned and flushed to eliminate any foreign matter. An appropriate filter should be fitted upstream if any particle present is likely to be greater than 50 microns. 5. Solenoid valves should not be used where they act directly on the instrument B A 126 C B C 106 D E F 250 G 49 H 1/2 1 2 D I 34 J Size Model Max Water Flow Max Air Flow Pressure Drop L/h 20 o C m 3 /h at 20 o C, bar abs At Max Flow (mbar) 15mm GMT* GMT* GMT* GMT* mm GMT* GMT* GMT* GMT* GMT* mm GMT* GMT* GMT* GMT* * In the model code, GMTB represents Brass and GMTS Stainless Steel flow tube construction. The final suffix is L for Liquid and G for Gas operation. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However,we do not accept liability for damage,injury,loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria office@lico.at Tel HWAR DS1221 Page 2 of 2

7 FLOW Product Data Sheet Vampire - Electronic Indicator DS1225 TYPE GMTX OPERATING PRINCIPLE The GMTX electronic indicator with microprocessor enhanced performance and LCD panel display of flow rate and total, designed for use with a metal tube variable area flowmeter for liquid, gas or steam measurement, Suitable for use with body options, the VAMPIRE (Variable Area Micro Proc-essor Indicator Readout Electronics) has a totally solid state measurement system, eliminating mechanical hysteresis errors. Microprocessor interpolation between flow data points, stored in factory calibrated look-up tables, gives an improvement to ±1% accuracy for this technique. The loop powered 4-20mA transmitter is certified intrinsically safe to CENELEC standards, for use in a potentially haz-ardous area. Both loop powered and AC mains powered units have separate high and low flow alarm outputs. The VAMPIRE is a metal tube variable area flowmeter: as the flow up through the precision machined tapered tube increases, the float rises, reaching an equilibrium position. Electron beam welded within the float casing is a magnet. Two Hall effect magnetic field sensors measure both the vertical and horizontal components on this field. The angle of the magnetic field defines the position of the float in the tapered tube. This solid state measurement eliminates the problems of mechanical hysteresis associated with conventional magnetic pointers. Field angle is also independent of the absolute value of magnet strength, and sensor sensitivity. ask for maintainance & operations manual OMM1033 FEATURES 4-20mA Transmitter Intrinsically safe approval Liquid or Gas Flow Calibration Built-in Flow Totaliser Operator adjustable High and Low Alarms 1% Accuracy VA meter reliability Program setting password protection office@lico.at DS1225 Issue 3: Page 1 of 3

8 The measurements are compared with a look-up table of field and flow data, stored in the VAMPIRE microprocessor memory on factory flow rig calibration. Flow rate is deduced accurately by interpolation between data points. The micro-processor converts the flow rate to correct Engineering units for the digital display on the LCD, adjusts the display meter pointer and 4-20mA output, sets the Alarm status and increments the totaliser as necessary. Keypads on the VAMPIRE front panel are used to set flow alarm levels, zero the totaliser and select the digital display as rate or total. Via a password entry procedure, the site engineer can reset the display units or even rescale the flowmeter to allow for changes to process conditions. This programme also has selections to define what functions are accessible to the operator (without password), plus zero, span and time constant adjustments. FLOW RANGES Model Flow Digit Water Air Max P Digit (L/hr) (m 3 /hr) (mbar) GMTX 1 (15mm/1/2 Ø 250 Long) GMTX (25mm/1 Ø 250 Long) , GMTX (50mm/2 Ø 250 Long) GMTX (80mm/3 Ø 300 Long) GMTX (100mm/4 Ø 400 Long) NB Ranges are quoted for Water at 20 o C, Air at ATP (1.013 Bar and 20 o C). Flow ranges for other fluids or process conditions on application. Units will be calibrated for customers specific conditions. Normally, scales offer 10:1 operating turndown. Pressure drops quoted are at maximum flow rates. SPECIFICATION Temperature Ambient GMTX: 50 o C GMTA: 70 o C Fluid 300 o C Housing Polyester coated aluminium. Weatherproof to IP65 Glands 4 off suitable for 2-5mm cable. Earth Stud External M6 stud fitted. GMTXA V, 50-60Hz, 0-2A max - current consumption GMTXD 24Vdc loop powered (12V min, 30V max Display LCD 0-100% analogue scale 90mm long. Digital Display, 4/5 digits 10mm high. Selectable for Flow Rate or Total. Calibration ±1% FSD Analogue output GMTXA 20mA into 600Ω max. GMTXD 4-20mA, 2 wire transmitter. Resolution 0.5%on current output, 80mA Alarm output GMTXA: 2 x 8A SPCO 230V ac max 100mA, max switched 30V, Internal Impedance 100Ω. GMTXD: 2 x open collector transistors. Totaliser Display 1-19,999. Pulse output selectable instead of flow alarm output. 50msec pulse length. Max pulse rate 2/sec (GMTXD). Approvals GMTXD is intrinsically safe approvded to CENELEC EExia IIBT4. CRN (Contact Sales for details). Zener Barriers 28V, 300W for 20mA line. 10V, 50W for alarm signals. DISPLAY Liquid Crystal Display Panel KEYPADS High Alarm Value Flow Rate Meter (% Scale) Alarm Messages Flash (when tripped) Programme Prompts Low Alarm Value Reset Totaliser (if programme allows) Select Rate or Total Display Enter Programme via Password Engineering Units Selected for Digital Display Digital Display - Flow Rate or Flow Total office@lico.at DS1225 Issue 3: Page 2 of 3

9 METAL TUBE FLOWMETER FAMILY VAMPIRE flow measurement electronics can be supplied with any of the Platon metal tube variable area flowmeters in the GMT family (see leaflet DS1221 Screwed and DS1220 Flanged). INSTALLATION 1. Ensure that no ferromagnetic material is situated within 100mm of the indicator. 2. Model GMTXA has output relays de-energised for alarm conditions. 3. Model GMTXD transistor outputs are off for alarm conditions. The negative line is common to the transistor outputs and the loop supply. 4. Intrinsically safe installations of Model GMTXD should be in accordance with BS5345 Part 4. The 4-20mA loop should be protected by an approved standard 28 Volt 300W shunt diode safety barrier. If required, the alarm outputs should be connected via approved 10 Volt 50W safety barriers. 5. It is recommended that the VAMPIRE LCD display is protected from both extremes of freezing and direct sunlight. FEATURES IP65 Keypad Microprocessor Computation and Calibration look-up tables Liquid Crystal Display Panel Solid State Magnetic Field Sensors Separate Terminal Box Tapered Flow Tube Float Magnet Inside Electron Beam Welded Casing Pulsation Damper on Gas Flow Meters Flanged or Screwed Connections Stainless Steel, Brass or Ptfe Lined Tube Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.. LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria Tel DS1225 Issue 3: Page 3 of 3

Glass Variable Area Flowmeters

Glass Variable Area Flowmeters FLOW Product Data Sheet DS1112 Glass Variable Area Flowmeters GAPMETER TYPES LG/NG Easy to Use, high visibility scale Simple and reliable Gas or Liquid flow measurement Operator confidence from float rotation

More information

Glass Variable Area Flowmeters

Glass Variable Area Flowmeters FLOW www.platon-direct.eu Product Data Sheet DS1115 Glass Variable Area Flowmeters FLOWMETERS LGX/NGX Improved industrialised construction Easy to use, high visibility scale Rear blow out safety vent Ergonomic

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

200A Series ELECTRONIC LEVEL TRANSMITTER

200A Series ELECTRONIC LEVEL TRANSMITTER MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC

More information

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering

More information

Variable Area Flow Meters

Variable Area Flow Meters PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

VA40 - VA45 Technical Datasheet

VA40 - VA45 Technical Datasheet VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range INSTRUCTION MANUAL process TM Ultrasonic Flowmeter Range process TM CONTENTS Page No 1 General 4 2 Order Codes 4 3 Installation 5 & 6 4 Specifications 7 & 8 1 General 3 Installation The Process Atrato

More information

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :

More information

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you? Technical Datasheet Pressure Transmitter: Analogue Series 387 387 ISSUE G High Accuracy ± 0.15%. Ranges from 1 bar to 1000 bar. 4 : 1 turndown. 4-20mA analogue with digital communications. 316 stainless

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators Data sheet DS/AK EN Rev. J AK Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators Superior technology and quality from the world leader in hydrogen measurement ATEX compliant intrinsically

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

Flow metering in gases Introduction to COMBIMASS family

Flow metering in gases Introduction to COMBIMASS family Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

analytical bulk flow distance FLOW level pressure temperature industrial communication

analytical bulk flow distance FLOW level pressure temperature industrial communication analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

Pro-V Multivariable Flowmeter

Pro-V Multivariable Flowmeter Pro-V Multivariable Flowmeter Model M23 Insertion Meter M23-V flowmeter provides cost-effective volumetric flow monitoring solution for most liquids M23-VT incorporates temperature sensing to provide a

More information

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual

More information

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators ABB MEASUREMENT & ANALYTICS DATA SHEET AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators AK100 S E RIE S ATEX COMP LI AN T GAS ANALY ZE R SYSTE M DS/AK100-E N RE V. O Measurement

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Variable area flowmeter F VA 250

Variable area flowmeter F VA 250 Fig. variable area flow meter pplication The V 5 variable area flowmeters with a standard length of 5 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits

More information

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure

More information

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER TFE-Lined Varea-Meter PVC-Tube Varea-Meter USFilter s Wallace & Tiernan Products offers a choice of two straight-through rotameters for metering difficult fluids and gases. The TFE-lined Varea-Meter is

More information

Gas Pressure Regulator HON 200

Gas Pressure Regulator HON 200 Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue Catalogue and Performance Literature for J48 Gas Pressure Regulators 2½ 6 Sizes Catalogue General Information CS4807C Regulating Capacity Flow Capacity Figures 2½ & 3 DS4819A Flow Capacity Figures 4 &

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Ultra High Purity Model 780S

Ultra High Purity Model 780S Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Technical Manual. Liquid Level Transmitter CT801-LB/S

Technical Manual. Liquid Level Transmitter CT801-LB/S CT801-LB/S Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CT801-LB/S 1 st Edition Released

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

IGTM Gas Turbine Meter. with electronic outputs and mechanical counter. Documentation and Technical Specifications

IGTM Gas Turbine Meter. with electronic outputs and mechanical counter. Documentation and Technical Specifications IGTM Gas Turbine Meter with electronic outputs and mechanical counter Documentation and Technical Specifications Gas - Measurement New size available: DN 400 (16 ) G 6500 Please inquire! General The vemm

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20) VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent

More information

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex

More information

Ultrasonic level transmitter and indicator

Ultrasonic level transmitter and indicator Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive

More information

TH-1800-T TRX-700-CNG Converter

TH-1800-T TRX-700-CNG Converter TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information