Possibilities to inspect seed treatment equipment

Size: px
Start display at page:

Download "Possibilities to inspect seed treatment equipment"

Transcription

1 Possibilities to inspect seed treatment equipment SPISE 6th European Workshop Barcelona Hans-Jürgen Osteroth (Schriftgröße mindestens 16, besser 1 Institute for Application Technique in Plant Protection, Messeweg 11-12, Braunschweig

2 Actual Situation (in Germany) Which kind of Seed Treatment Equipment (STE) we find currently on the market How to inspect seed treatment equipment and what is needed Established certification system in Germany for dust-free seeds Next steps Some suggestions for requirements

3 Actual situation (in Germany) The inspection for seed treatment equipment (STE) must be indroduced before the end of the year 2020 German ArtikelVerordnung from 27 June 2013 based on the plant protection act from 13 February 2012 The discussion of how to implement the inspection of the equipment is just starting For the moment we don t have any standards neither for brand new STE nor for STE in use Both mobile STE (rarely) and stationary equipment (mostly) can be found The equipment can be located -on farms, -on the field (mobile), -at contractors, -in warehouses

4 The discussion of how to implement the inspection of the equipment is just starting! Many questions: Inspection staff is not yet available and must be trained first Most of the inspections are carried out on farms, at contractors or on company ground inspectors must travel overland Inspection equipment must be transportable Which equipment is needed? For the inspection sufficient quantities of seed are needed must the farmer/contractor provide it? For checking and calibration often Plant Protection Products (PPP) are necessary work safety must be considered

5 No standards for STE in the moment CEN already announced not to draw up new standards for STE JKI guideline for for new equipment for the JKI approval exist (these requirements are valid until 2011 in the declaration procedure) Requirements for STE in use are needed soon

6 Which devices can be found at the moment? Mobile STE - for potatoes - for cereals

7 Which devices can be found at the moment? Problem of the definition: Mobile seed treatment equipment? or Sprayer for field crops on a potatoe planter? In Germany inspection as a row sprayer for field crops (inspection since this year)

8 Which devices can be found at the moment? STE on farms STE for potatoes Inspection? Out of the internet: Tractor mounted mixing unit for -feed mixing, -mixing granules and -seed treatment! From Old concrete the museum mixer into as STE internet seccond auction life Picture: Eskil Nilsson

9 Which devices can be found at the moment? STE at contractors Seed treatment equipment Seed cleaning device Mobile STE - seed treatment with electrons! Inspection?

10 Which devices can be found at the moment? STE for laboratories or chemical industry STE in industry often work with more than 20 t/h. The seed treatment equipment is often located over more than one floor! Work safety is important but is not often used! Picture: Bayer Picture: Eskil Nilsson

11 How to inspect seed treatment equipment and what is needed - inspection stuff must be trained in STE - inspection take place on company ground / farms / contractors = Inspection stuff and equipment must be transportable - which equipment is needed? easy: balance, flowmeter, stopwatch, measuring cylinders more complicated: Photometer, if chemical evaluation of treated seed is needed -> mobile equipment available and practicable?

12 What to inspect every three years? A) Dosage accuracy - Pump: function test, leakages - Controls: Pressure gauge if present - Flow meter: function test and accuracy - Balance: accuracy by using calibrated weights - Nozzles (if present): Flowrate measurements (if possible General problem: Often seed and PPP are needed. The test with water is not sufficient!

13 What to inspect every three years? B) Tightness and safety of equipment - Hoses and lines: leakages - Container lid: leakages - Dust extraction (if present): damages, leakages - Dust disposal: container? - Safety of drives: drives guarded?

14 What to inspect every three years? C) Work quality - grain distribution µg/corn: not possible, because of the needed intruments (Photometer) - grain degree (ml/100 kg seed): not possible, because of the needed instruments - automatic functions: + machine stops automatically when seed is missing + machine stops automatically when PPP container is empty But: Not all devices have this feature (esp. devices at farms) Can be visually checked

15 The Established certification system in Germany for dust-free seeds (voluntary) observe the complete process from grain deliverey to filling of the finshed seed! Investigate as part of the certification process also pickling units It is conceivable to inspect the devices during certification The experience shows, that calibration of the equipment must be regularly checked and documented by the user! Adjustment of the dosage has to be checked by the user for each new batch of seed! If documents are available, further analysis of the dosage could be omitted thereby

16 The Established certification system in Germany for dust-free seeds (voluntary) observe the complete process from grain deliverey to filling of the finished seed! Experience of the certification up to now: The certification process often shows - Leakages at the pickling units - Poorly cleaned devices -Encrustations of seed and PPP that complicate proper operation of the machine and makes the inspection of the device for the stuff difficult and may cause health problems when handling with PPP. Inspection of STE with the use of PPP is a no go! The use of water for funktion tests produce inconclusive results especially with beet and rape seed.

17 Next steps: The inspectable devices must be determined Requirements for STE in use must be worked out Inspection stuff must be trained In relation to the (not yet worked out) requirements appropriate test equipment is needed It is proposed for this purpose to draw up an SPISE Advice paper! Please find in the full paper of my presentation the proposed requirements as a basis for further discussions.

18 Possible requirements for STE in use Filtering Pipes and / Atomizer hoses / Other a) Emptying Equipment 2. Filling Fittings There shall Seed and and / Cleaning treatment: PPP Controls be no leakages by Containers: 1. a) 4. It a) Safety: No All pipes If Dosage: filters shall devices or be are hoses possible Storage splashing Drive for installed container elements back measuring, while tor testing collect lines, large such switching the the enough, as a) remaining b) b) drive Container maximum filter Dose and inserts rate Calibration shaft, off obtainable PPP lid and of shall PPP chain, must free adjustinf simply be must working without be from sprockets, flow be possible rates tools, possible belts, reliably gears, deformations shall pressure changeable. to read work and at for = collecting etc. reliably a without the easy system. need of and seed to holes with accessible spillage be and checked. no leakages place PPP c) b) b) Complete PPP must easily and completely For Level Hoses The separately equipment manual filter(s) shall emptying shall be of liquid controls positioned be of in must with electric be which containers good determined are drive, must collected be possible separately for one from person the seed c) STE make by necessary such condition a way, and a stopped scale sure for that the that the there mesh automatically the application are size no electrical shall c) c) The The cleaning dosage device setting for must crop be when clearly d) connections Agitation be sharp correspond mounted bends to seed flow (if stopped present): in and the (connectors, such nozzle(s) a abrasion There way, cables) that must they protection visible (clearly product recognizable) containers, if FDi d) STE are be can which fitted a free be in makes stopped good easily the STE. the of visible bruises, reached woven automatically agitation cracks, and fabric c) provided, shall work reliably when e) deformations Pressure readjusted visible. Atomizer(s) PPP flow compensation (if for necessary) PPP shall stopped or exposed must during not be wires. be the e) Adjusting ensured application affected in their function, for of the volume weight of c) Other example, measuring by encrustations devices, / dirt. d) seed especially Other equipment flow meters must used be for the f) Hoses, lines, pumpes free from dosage functional. shall measure within a leaks maximum error of 5 % of the real g) Means for removing dust must data work properly

19 Not to be inspected with the proposed requirements: Quality of treated seed PPP on the single corn (µg/corn) PPP on a sample (mg / 50 g seed) The amaount of dust in the seed Dosage with PPP / Water / Seed Proper storage of PPP

20 A lot to do Thank you for your attention! Mail: Tel.:

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

Laboratory Mortar Mixer (Testing)

Laboratory Mortar Mixer (Testing) TomTom-Tools GmbH Zelgli 20 8905 Arni info@tomtom-tools.com Switzerland www.tomtom-tools.com User Manual Version February 22, 2015 Laboratory Mortar Mixer (Testing) 1 Introduction The Laboratory Mortar

More information

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS NPTC Registered Charity No. 1096429 ABBEY PARK, STARETON, WARWICKSHIRE, CV8 2LY Tel: 024 7685 7300 Fax: 024 7669 6128 Email: information@nptc.org.uk NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF)

More information

Risk Management Resources

Risk Management Resources Risk Management Resources Machine Guarding Name: Notes: Electrical Systems: Fire Prevention Are circuit breakers accessible to personnel, protected from physical damage, and located away from ignitable

More information

User Manual for the Application of Hose Assemblies for High-Pressure Water Jet Machines

User Manual for the Application of Hose Assemblies for High-Pressure Water Jet Machines User Manual for the Application of Hose Assemblies for High-Pressure Water Jet Machines Germany GmbH & Co. KG polyflex Division An der Tuchbleiche 4 68623 Lampertheim (Hüttenfeld) Tel.: +49 (0)6256 81-0

More information

RH800 & 2000 BASIC OPERATIONS

RH800 & 2000 BASIC OPERATIONS RH800 & 2000 BASIC OPERATIONS 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding

More information

Four common PRESSURE CALIBRATION PAIN POINTS

Four common PRESSURE CALIBRATION PAIN POINTS Four common PRESSURE CALIBRATION PAIN POINTS Pressure calibration is often critical to process control systems, helping to optimize operations and ensure plant safety. While pressure instrumentation can

More information

General maintenance engineering applications

General maintenance engineering applications Unit 868 General maintenance engineering applications UAN: J/600/6007 Level: Level 2 Credit value: 12 GLH: 55 Relationship to NOS: Endorsement by a sector or regulatory body: Aim: This unit has been derived

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. Specialty gases in small cylinders Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. 02 Specialty gases in small cylinders Our specialty gases guarantee precision.

More information

General maintenance engineering applications

General maintenance engineering applications Unit 068 General maintenance engineering applications Level: 2 Credit value: 12 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

Operating instruction

Operating instruction Operating instruction MV, XV, HG, HP, RKO, D2G, TV, BV, WB & SLV 1 Introduction 2 2 Stafsjö s knife gate valves 2 3 Technical information 2 3.1 Pressure test 2 3.2 Labelling 2 4 Storage 3 5 Transportation

More information

THE UNIVENTOR 400 ANAESTHESIA UNIT

THE UNIVENTOR 400 ANAESTHESIA UNIT THE UNIVENTOR 400 ANAESTHESIA UNIT TABLE OF CONTENTS EDITION 3 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section

More information

USER MANUAL. MACMAG magnetic separator MHK MHF

USER MANUAL. MACMAG magnetic separator MHK MHF USER MANUAL MACMAG magnetic separator MHK MHF Important Read the safety precautions before use. Thank you for your purchase. This user manual contains important information on avoiding damage and personal

More information

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW INSTRUCTION MANUAL FOR Chlorinator M 3600 C 2014 Controlmatik ABW 1 CONTENTS 1. General... 3 2. Operation... 4 2.1 Automatic control... 6 2.2 Manual control - 1... 6 2.3 Manual control - 2... 6 3. Motor

More information

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6 COMMON PRECAUTIONS Page 1 of 6 These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution",

More information

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE www.helantec.de Gas filling - visibly better! 2 Managing partners Jochen Weiß and Gregor Witrofsky Advantage for you Worldwide, HELANTEC is the

More information

Western Sydney University Safety Inspection Checklist - Laboratory Environments

Western Sydney University Safety Inspection Checklist - Laboratory Environments Western Sydney University Safety Inspection Checklist - Laboratory Environments Useful Hint: To maximise the benefits that can be gained from a workplace inspection activity read the Western Sydney University

More information

VACCUPERM Vacuum chlorine gas dosing systems

VACCUPERM Vacuum chlorine gas dosing systems VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,

More information

VITLAB micropipette. Standard Operating Procedure (SOP)

VITLAB micropipette. Standard Operating Procedure (SOP) VITLAB micropipette Standard Operating Procedure (SOP) VITLAB GmbH Linus-Pauling-Str.1 63762 Grossostheim Germany tel: +49 6026 97799-0 fax: +49 6026 97799-30 info@vitlab.com www.vitlab.com Table of contents

More information

PRIME TURF (MAPP 14617) Contains 255 g/l (25% w/w) iprodione as a suspension concentrate.

PRIME TURF (MAPP 14617) Contains 255 g/l (25% w/w) iprodione as a suspension concentrate. PRIME TURF (MAPP 14617) Contains 255 g/l (25% w/w) iprodione as a suspension concentrate. PRIME TURF is a protectant dicarboximide fungicide with protectant and some eradicant activity for control of Fusarium

More information

Touch on the New button to create the new implement.

Touch on the New button to create the new implement. When you need to set up a new implement, touch on the Run Screen and the usual page will open. Touch on the Switch button for you implement & see if the required implement is there, if not, you will have

More information

Our technical information is based on Tip: calls attention to special information.

Our technical information is based on Tip: calls attention to special information. SUPPLY TANKS (CBP) 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding to install

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual EMISSION CHAMBERS Bulk and Surface Emission Detection for the RAD7 User Manual TABLE OF CONTENTS INTRODUCTION 3 1 SYSTEM CONFIGURATION 4 1.1 Closed Loop Configuration 4 Fig. 1 Emission Chamber Closed Loop

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

Corning Step-R. Repeating Pipettor. Instruction Manual

Corning Step-R. Repeating Pipettor. Instruction Manual Corning Step-R Repeating Pipettor Instruction Manual Table of Contents 1. Introduction... 1 2. Using the Step-R Repeating Pipettor... 1 3. Corning Syringe Tips... 4 4. Recommendations... 5 5. Recalibration...

More information

Smart Water Application Technologies (SWAT) TM

Smart Water Application Technologies (SWAT) TM Smart Water Application Technologies (SWAT) TM Equipment Functionality Test Protocol Version 2.3 June 2014 SWAT Committee 8280 Willow Oaks Corporate Drive Suite 400 Fairfax, VA 22031 www.irrigation.org

More information

PAPR Flow Tester. instructions. part no WARNING

PAPR Flow Tester. instructions. part no WARNING PAPR Flow Tester part no. 488903 instructions WARNING This manual, including warnings and cautions inside, must be carefully read and followed by all persons who use or maintain the product, including

More information

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) MODULE PA4S PESTICIDE SLUG PELLET APPLICATOR

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) MODULE PA4S PESTICIDE SLUG PELLET APPLICATOR NPTC Registered Charity No. 1096429 BUILD 500, ABBEY PARK, STARETON, WARWICKSHIRE CV8 2LY Tel: 024 7685 7300 Fax: 024 7669 6128 Email: information@nptc.org.uk NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES

More information

Transferpette -8/-12

Transferpette -8/-12 Transferpette -8/-12 Testing Instructions (SOP) May 2009 1. Introduction The standard DIN EN ISO 8655 describes both the design and the testing of the piston operated pipette Transferpette 8/ 12. The following

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting

More information

FABRICATED ROTARY AIRLOCK

FABRICATED ROTARY AIRLOCK FABRICATED ROTARY AIRLOCK INSTRUCTION, OPERATIONS & MAINTENANCE MANUAL CLEAN AIR MANAGEMENT COMPANY, INC. 8224 Nieman Road i Lenexa, Kansas 66214 Phone: 913-831-0740 Fax: 913-831-9271 TABLE OF CONTENTS

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009 Transferpette Testing Instructions (SOP) May 2009 1. Introduction The standards DIN EN ISO 8655 describe both the design and the testing of the piston operated pipette Transferpette. The following Testing

More information

Farm Chlor Chlorinator Instruction Manual

Farm Chlor Chlorinator Instruction Manual Farm Chlor Chlorinator Instruction Manual 1 2 GEA FIL FARM CHLOR CHLORINATOR INSTRUCTION MANUAL Content Welcome to improved water quality 3 Key Features and Benefits Chlorine Use What s included? 4 Installation

More information

MES Flowmeter Sizes - Specifications. ManuFlo (c) Manu Electronics 2015

MES Flowmeter Sizes - Specifications. ManuFlo (c) Manu Electronics 2015 MES Flowmeter Sizes - Specifications 75 112 185 * 1 MES20 Flowmeter How it Measures Is a Positive Displacement type o Measures volume of liquid flowing by counting repeatedly the filling and discharging

More information

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010) (Ref. SOP QMS-080; EHS-010) Form-445 Inspected by: Date of inspection Date of Report Report # Pages Area Manager: Area Inspected: General This EHS Workplace Inspection was conducted by: Scope of the Inspection:

More information

Best Practice for Calibrating LTH Conductivity Instruments

Best Practice for Calibrating LTH Conductivity Instruments Application Note Best Practice for Calibrating LTH Conductivity Instruments As accurate process measurement becomes an everyday requirement it is vital to be able to calibrate conductivity instruments

More information

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES GAS SAFETY ENGINEERING GAS MANIFOLD SYSTEMS AUTOGENOUS ENGINEERING FLAME SPRAYING GAS MIXERS IBEDA GAS MIXERS FOR MANY AREAS OF

More information

COLSTAR Fungicide MAPP 12175

COLSTAR Fungicide MAPP 12175 F d COLSTAR Fungicide MAPP 12175 An emulsifiable concentrate containing 160 g/l (16.4% w/w) flusilazole and 375 g/l (38.5% w/w) fenpropimorph and for broad-spectrum disease control in barley and winter

More information

Surface exploration drilling

Surface exploration drilling Checklist Surface exploration drilling This checklist is intended to assist employers to identify common hazards and manage risks associated with surface exploration drilling. June 2017 Background In surface

More information

DRILL MAINTENANCE ADJUSTMENTS BEFORE GOING TO THE FIELD

DRILL MAINTENANCE ADJUSTMENTS BEFORE GOING TO THE FIELD FOLDING NO-TILL Air DRILL 3N-4010HDA 3-SECTION DRILL MAINTENANCE Proper servicing and adjustment is key to the long life of all farm equipment. With careful and systematic inspection of your grain drill,

More information

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

Module No. # 01 Lecture No. # 6.2 HAZOP (continued) Health, Safety and Environmental Management in Petroleum and Offshore Engineering Prof. Srinivasan Chandrasekaran Department of Ocean Engineering Indian Institute Of Technology, Madras Module No. # 01

More information

Ritter AquaBottleSystem

Ritter AquaBottleSystem J1174, V02.00.00 J1174, V02.00.00 Page 0 Concept GmbH Table of Contents 1 General guidelines 2 2 Reference for the disinfection of the dental unit 3 3 Filling of the bottle 4 4 Execution of disinfection

More information

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. SAFETY GUIDELINES

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection WHITE PAPER In today s protective coating industry, there is a growing demand to proportion and

More information

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements

More information

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Page 1 of 6 TPS Australia - Quality hand-made instruments since 1968. Nothing's as cool, as a freshwater pool easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Automatic

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

SAUTER FK Version /2016 GB

SAUTER FK Version /2016 GB Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Tel: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Digital Force Gauge SAUTER FK Version 1.4 12/2016

More information

icon i150 / i350 Installation / Operation Manual

icon i150 / i350 Installation / Operation Manual i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

Transferring and Storage

Transferring and Storage Organometallics Transferring and Storage A dip tube is available for Container 2 which can be screwed into the neck to permit safe transfer of product. Small quantities of metal alkyl can be withdrawn

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL CO2 MANUAL Page 1 of 10 General This control equipment has been designed to add CO2 (carbon dioxide) to a swimming pool to control the ph level downwards.

More information

NIV EAU MATIC ST User Manual Made in Canada

NIV EAU MATIC ST User Manual Made in Canada NIV EAU MATIC ST User Manual Made in Canada www.niveaumatic.com info@niveaumatic.com -2- Table of contents Introduction Section 1 Page 4 Installation Section 2 Pages 5 to 10 2.1 Control box 2.2 Sensor

More information

Valve test benches. Systems overview

Valve test benches. Systems overview Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Shade Sails - Installation Tips

Shade Sails - Installation Tips Shade Sails - Installation Tips Shade Sails Installation Suggestions Design and Layout: Shade Sails can be mounted in a variety of ways. Sails can be mounted flat or with high and low points. A flat sail

More information

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1 Serial No. H-V066-E-3 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

Z5160 Load adapter Mounting instructions (1.2 EN)

Z5160 Load adapter Mounting instructions (1.2 EN) Z560 Load adapter Mounting instructions (. EN) WARNING! CAUTION! IMPORTANT! Note: References in the manual This refers to a potentially dangerous situation which may lead to personal injury. This refers

More information

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment Overview This standard covers a broad range of basic fluid power maintenance competences which will prepare you for entry into the engineering or manufacturing sectors, creating a progression between education

More information

No-Till Drill Use Agreement

No-Till Drill Use Agreement No-Till Drill Use Agreement (Landowner), will rent the 606NT Drill on (date) and will return the drill by (date). The drill will be picked up and returned at the Johnson County Public Works Department

More information

1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT

1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT This symbol means: ATTENTION - BECOME ALERT YOUR SAFETY IS INVOLVED. When you see this symbol

More information

Associated Hazard (outcome) Control Measures. Reduction of water supply

Associated Hazard (outcome) Control Measures. Reduction of water supply Raw water Intake Low lift pumphouse Structural failure of intake Source water Inability to pump-all 4 pumps (loss of power, etc.), structural failure, fire Loss of the 2 larger capacity pumps Structural

More information

Technical Service Bulletin March 2015 TSB142.01

Technical Service Bulletin March 2015 TSB142.01 Technical Service Bulletin March 2015 TSB142.01 Commissioning Procedure for HYDRAcap This Technical Service Bulletin provides information for commissioning of a HYDRAcap membrane system in a water treatment

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

We measure it. For gas and water installers. testo hpa. bar

We measure it. For gas and water installers. testo hpa. bar Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine

More information

MAPP PCS No Syngenta UK Limited CPC 4, Capital Park, Fulbourn, Cambridge CB21 5XE Tel: Cambridge (01223)

MAPP PCS No Syngenta UK Limited CPC 4, Capital Park, Fulbourn, Cambridge CB21 5XE Tel: Cambridge (01223) L1042628 GBRI/05W PPE 4095335 1257/17 BANNER MAXX ll is an emulsifiable concentrate formulation containing 162 g/l propiconazole A broad spectrum foliar fungicide with systemic properties for control of

More information

ACCESSORIES CATALOGUE. Guarany offers a complete line of accessories to optimize many spraying applications, assuring the best cost-benefit.

ACCESSORIES CATALOGUE. Guarany offers a complete line of accessories to optimize many spraying applications, assuring the best cost-benefit. ACCESSORIES CATALOGUE Guarany offers a complete line of accessories to optimize many spraying applications, assuring the best cost-benefit. 2 BOOMS HORIZONTAL REAR BOOM (6 NOZZLES) U9888.00.00 VERTICAL

More information

TRAINING ON ANTAM STANDARD CODE For TESTING OF KNAPSACK MISTERS CUM DUSTERS

TRAINING ON ANTAM STANDARD CODE For TESTING OF KNAPSACK MISTERS CUM DUSTERS TRAINING ON ANTAM STANDARD CODE For TESTING OF KNAPSACK MISTERS CUM DUSTERS PART - 8: TESTS & CHECKS FOR PERFORMANCE 2 16-28 October2016, Nanjing China 2nd Training of Trainers on ANTAM Codes Organized

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

HYDRAULIC MOBILE LIFTING TABLE

HYDRAULIC MOBILE LIFTING TABLE HYDRAULIC MOBILE LIFTING TABLE MODEL NO: HTL300 & HTL500 PART NO: 7610148 & 76210152 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1116 INTRODUCTION Thank you for purchasing this CLARKE

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

TJF-Q180V Cleaning and Disinfection Checklist

TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed

More information

CrimpFlex Crimping Guidelines

CrimpFlex Crimping Guidelines The following guidelines are suggestions to the design engineer and quality control personnel on proven methods of incorporating the CrimpFlex? contact into their designs and into their manufacturing and

More information

Read where you love to read the pool, the tub, or the beach with the waterproof Guardian Case for Kindle!

Read where you love to read the pool, the tub, or the beach with the waterproof Guardian Case for Kindle! INSTRUCTIONS AND WARRANTIES GUARDIAN CASE FOR AMAZON KINDLE LATEST GENERATION M-EDGE E-READING. E-NHANCED. TABLE OF CONTENTS STEPS AND PROCEDURES FOR PROPER CASE FUNCTION.................. Section I STEPS

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

SNOW PICKETS` Climbing and Mountaineering Equipment. Foreword

SNOW PICKETS` Climbing and Mountaineering Equipment. Foreword SNOW PICKETS` Climbing and Mountaineering Equipment UIAA 155 Foreword This UIAA Standard is only published in the English language version, which is the master text. For any validations in translation,

More information

Risk Analysis and Hazard Reduction Report V1.0

Risk Analysis and Hazard Reduction Report V1.0 Risk Analysis and Hazard Reduction Report V1.0 2 Contents 1. Definitions and Risk Classifications 3 2. Risk and Hazard reduction associated with Personnel 4-5 3. Risk and Hazard reduction associated with

More information

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual OxyCheq Expedition-X Oxygen Analyzer Operator s Manual OxyCheq 3528 Russell Road Marianna, Florida 32446 USA Tel: 850.482.0385 Email: oxy@oxycheq.com Web: http://oxycheq.com CONTENTS 1.0 Introduction..

More information

Air Tractor Preventative Maintenance Manual And Troubleshooting

Air Tractor Preventative Maintenance Manual And Troubleshooting 1.0 Overview This maintenance schedule will assist in the maintenance and troubleshooting procedures for the Unified Industries Air Tractor. The first portion of this section details the general maintenance

More information

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD Operating Manual ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD 50 und ALU-CD 60 KGW - ISOTHERM Gablonzer Straße 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com

More information

Transport of gas tanks for motor vehicles

Transport of gas tanks for motor vehicles United Nations Secretariat ST/SG/AC.10/C.3/2016/51 Distr.: General 30 August 2016 Original: English Committee of Experts on the Transport of Dangerous Goods and on the Globally Harmonized System of Classification

More information

Airbrush Diaphragm Compressor AS06

Airbrush Diaphragm Compressor AS06 Operation Manual Airbrush Diaphragm Compressor AS06 ARTICEL 34200 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further

More information

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight

More information

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

Operation Manual Airbrush Compressor AS196A ARTICLE 34207 Operation Manual Airbrush Compressor AS196A ARTICLE 34207 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Measurement And Control Appreciation

Measurement And Control Appreciation Measurement And Control Appreciation Course Content Aim To provide an appreciation of the operation and application of process plant instrumentation used for the measurement and display of the main process

More information

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use

More information

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST Release Date: January 7, 2014 Sampling Coarse Aggregate PERFORMANCE CHECKLIST AASHTO T-2 Sampling of Aggregates Sampling From A Stockpile 1 When

More information