Pressure relief valve DHV 716 set range: 0,5-10,0 bar
|
|
- Elvin McDaniel
- 6 years ago
- Views:
Transcription
1 Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of operating safety and long service life constant, low vibration control low-maintenance can be easily connected to the pipework by proven technologies - solvent or fusion welding metal inserts in the valve body allow the valves to be directly fitted to mounting sets, the movability of the union nuts remains unaffected reliable diaphragm fastening with standard stainless steel screws hermetically sealed by valve diaphragm with formed sealing rings short face-to-face dimension of the threaded variant Application chemical plants industrial plants water treatment Intended Use The pressure relief valve which is directly controlled by the medium, is used in technical processing plants for keeping preset working pressures constant on the primary side. The pressure relief valve can also be used as an overflow valve to prevent pressure peaks. In this case, the pressure relief valve is fitted in a bypass line. Valve Function When the valve is closed in the position of rest, the piston and/or valve seat is only impinged with the secondary pressure, when it is available. When the working or inlet pressure (primary side) rises above the set value, the diaphragm is lifted against the spring force. The valve opens and a pressure relief on the secondary side takes place. The ribbed diaphragm, dimensioned for full valve lift, separates the medium in the valve body from the bonnet and the atmosphere. The hermetic seal - especially in the higher temperature range - is ensured by formed sealing rings. Valve Setting Set or adjust the desired or permissible working pressure at the adjustment screw with the aid of pressure gauges (ASV diaphragm pressure gauge guard, type MDM 90) in the pipe system after removing the protection cap. The adjustment screw is secured by a counter nut and can be sealed against unauthorized adjustment, if necessary. Flow Media Technically pure, neutral and aggressive fluids, provided that the selected valve materials coming into contact with the media are resistant at the operating temperature according to the ASV-resistance guide. For nitric acid or sulfuric acid please specify the precise operating conditions of the application. Fluid Temperature see pressure-/temperature diagram Operating Pressure see pressure-/temperature diagram Set Range bar Nominal Pressure (H O, 0 C) PN 0 Working Pressure set pressure plus flow dependent pressure increase (see characteristic curves). Opening Pressure Difference ca. 0. bar Hysteresis Difference between opening and closing pressure approx. 0.3 bar Valve Body PVC-U PP PVDF Bonnet PP, glass fibre reinforced Diaphragm PTFE (EPDM diaphragm with PTFE coating on the surfaces coming into contact with the medium) Sealing FPM EPDM Screws stainless steel (.30) Actuation medium controlled (08) 9 00 (08) (03) (0) (07) /0
2 Connection union DIN 803 union socket end for solvent welding DIN ISO (PVC-U) union socket end for fusion welding DIN ISO (PP) union socket end for fusion welding DIN ISO (PVDF) spigot end for solvent welding DIN ISO (PVC-U) fusion spigot end DIN ISO (PP) fusion spigot end DIN ISO (PVDF) union socket end for fusion welding DIN ISO (PP) on request union socket end for fusion welding DIN ISO (PE) on request Flow Direction always in the direction of the arrow Mounting Position as required Fastening via threaded inserts (metal inserts) in the valve body Colour body: PVC-U, grey, RAL 70 body: PP, grey, RAL 703 body: PVDF, opaque, yellowish-white bonnet: orange, RAL 00 bottom section: PVC-U, grey, RAL 70 bottom section: PP, grey, RAL 703 bottom section: PVDF, opaque, yellowish-white Pressure Gauge Connection The pressure relief valve can be factory fitted with a pressure gauge for neutral media. The resistance of the pressure gauge material has to be taken into consideration for other media. The pressure gauge is normally connected to the primary side. (08) 9 00 (08) (03) (0) (07) /0
3 Pressure relief valves, Pressure relief valve DHV 7 Pressure/temperature diagram Pressure loss curve (standard values for H O, 0 C) P = pressure loss pressure loss and k v value The diagram shows the pressure loss P in relation to the flow Q. Conversion aid: c v = k v x 0.07; f v = k v x Units: k v [l/min]; c v [gal/min] US; f v [gal/min] GB Operating behaviour P = operating pressure T = temperature The pressure/temperature limits are applicable for the stated nominal pressures and a computed operating life factor of 5 years. These are standard values for harmless media (DIN 03), to which the valve material is resistant. For other media please refer to the ASV resistance guide. The durability of wear parts depends on the operating conditions of the application. For temperatures below 0 C (PP < +0 C) please specify the precise operating conditions of the application. The rated pressure depends on the valve size and material. For the corresponding rated pressure value of the valve, please refer to the»order table«. pe = set Pressure pö = opening pressure ps = closing pressure pö - ps = hystersis pe - pa = flow dependent pressure reduction (08) 9 00 (08) (03) (0) (07) /0
4 Pressure relief valves, Pressure relief valve DHV 7 Sectional drawing DHV 7 DHV 7 with pressure gauge A = primary side B = secondary side = protection cap = adjustment screw 3 = counter nut = piston 5= diaphragm = flat sealing ring 7 = valve seat The pressure relief valve can be factory fitted with a pressure gauge for neutral media. The resistance of the pressure gauge material has to be taken into consideration for other media.. (08) 9 00 (08) (03) (0) (07) /0
5 Pressure relief valves, Pressure relief valve DHV 7 Applications for Pressure Relief Valve Example : Constant system pressure Applications for Pressure Relief Valve Example 3: Pressure relief valve as backflow preventer X = valve opens Y = valve closed pp = pump pressure pö = opening pressure Applications for Pressure Relief Valve Example : Consumer and/or opens, pressure relief valve closes X = valve opens Y = valve closed pmax = max. pressure pp = pump pressure pö = opening pressure Applications for Pressure Relief Valve Example : Pressure relief valve as overflow valve:the container pressure or system must not exceed the max. pressure value X = valve opens Y = valve closed pp = pump pressure pö = opening pressure X = valve opens Y = valve closed pp = pump pressure pö = opening pressure (08) 9 00 (08) (03) (0) (07) /0
6 Pressure relief valves, Pressure relief valve DHV 7 Malfunctions, possible causes, rectification Maintenance note Screw tightening torque (Nm) The specified values apply to lubricated screws. Check the tightening torque of the body screws at certain intervals in case of setting of the diaphragms and/or temperature fluctuations. Operating note Safe operation of the valve can only be ensured if it is properly installed, operated, serviced or repaired by qualified personnel according to its intended use while observing the accident prevention regulations, safety regulations, relevant standards, directives/technical regulations or codes of practice such as e.g. DIN, DIN EN, DIN ISO and DVS*. *DVS = German Welding Society The intended use includes adhering to specified limit values for pressure and temperature, as well as checking the resistance. This requires all components coming into contact with the medium to be "resistant" in accordance with the ASV resistance guide. Pressure gauge version If the valve body is equipped with a pressure gauge, do not tighten the pressure gauge with more than max. 3 Nm. Please take into account that the material PTFE is classified as resistant against many media, however, PTFE is not diffusion tight when used as a film, e.g. for the ASV membranes. Please contact us for limit cases (nitric acid or sulfuric acid). (08) 9 00 (08) (03) (0) (07) /0
7 Pressure relief valves, Pressure relief valve DHV 7 body PVC-U size d(mm) pressure range DN(mm) DN(inch) 3/8 / 3/ / / PN(bar) setting range (bar) Connection sealing ident No. PVC-U EPDM socket end DIN ISO FPM weight kg kg kg 905. kg kg kg kg PVC-U EPDM spigot end DIN ISO FPM weight kg kg kg kg kg kg kg body PP size d(mm) pressure range DN(mm) DN(inch) 3/8 / 3/ / / PN(bar) setting range (bar) Connection sealing ident No. PP EPDM socket end DIN ISO FPM weight kg kg 905. kg 90.5 kg kg kg kg PP EPDM spigot end DIN ISO FPM weight kg kg kg 988. kg kg kg 99.8 kg (08) 9 00 (08) (03) (0) (07) /0
8 Pressure relief valves, Pressure relief valve DHV 7 body PVDF size d(mm) pressure range DN(mm) DN(inch) 3/8 / 3/ / / PN(bar) setting range (bar) Connection sealing ident No. PVDF socket end DIN ISO PVDF spigot end DIN ISO FPM weight FPM kg kg kg kg kg kg kg 005 (08) 9 00 (08) (03) (0) (07) /0
9 Pressure relief valves, Pressure relief valve DHV 7 dimensions d(mm) DN(mm) DN(inch) 0 3/8 0 5 / 5 0 3/ / 50 0 / 3 50 dimensions(mm) PP/PVC-U PVDF PP/PVC-U PVDF PP/PVC-U PVDF d h h L L L L3 L3 t H N V (08) 9 00 (08) (03) (0) (07) /0
10 Pressure relief valves, Pressure relief valve DHV 7 Item Overview position quantity designation valve body bonnet separating disc pressure disc diaphragm pressure plate spring plate pressure spring steel ball piston piston point disc steel ball hexagon nut O-ring protection cap hexagon nut disc union end union nut protection cap protection cap disc Plug position quantity designation valve body bonnet separating disc pressure disc diaphragm pressure plate spring plate pressure spring steel ball piston piston point disc steel ball hexagon nut O-ring protection cap hexagon nut disc union end union nut protection cap protection cap disc Plug (08) 9 00 (08) (03) (0) (07) /0
11 Pressure relief valves, Pressure relief valve DHV 7 Characteristic curves Configuration example The valve is set tight at 5 bar. A flow of approx. 000 l/h is reached at a pressure increase of bar. According to the curve, this results in the following values: set pressure pe: 5 bar; working pressure pa: bar; opening pressure pö: 5. bar; closing pressure ps: 5. bar DN 0 DN 0 DN 5 DN 5 (08) 9 00 (08) (03) (0) (07) /0
12 Pressure relief valves, Pressure relief valve DHV 7 DN 3 DN 0 DN 50 (08) 9 00 (08) (03) (0) (07) /0
Pressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationPressure relief valve DHV 718
Pressure relief valve DHV 78 Benefits diaphragm controlled pressure relief valve with piston guidance simple design, reliable function particularly suitable for oscillating pumps constant, frictionless
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More informationPressure Relief Valve DHV 718
Pressure Relief Valve DHV 718 Nominal size DN 8 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 0.5 to 10 bar diaphragm controlled pressure relief valve simple design,
More informationPressure Reducing Valve DMV 750
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction
More informationBody Material: PVC, PP, PVDF Bonnet Material: Glass Filled PP Size: ½ - 2 Pressure Rating: 150 psi Set Pressure: 4 to 150psi Seals:
Pressure Relief Valve Body Material: PVC, PP, PVDF Bonnet Material: Glass Filled PP Size: ½ - Pressure Rating: 50 psi Set Pressure: to 50psi Seals: EPDM, FPM, PTFE Piston: PVC, PP, PVDF, PTFE Diaphragm:
More informationAeration and vent valve BE 891
Aeration and vent valve BE 89 Advantage high level of operating safety and long service life low-maintenance can be easily connected to the pipework by proven technologies - solvent or fusion welding Application
More informationPressure Reducing Valve
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Advantages high reproducibility of setting pressure
More informationpressure reducing valves
pressure reducing valves The function of a pressure reducing valve A pressure reducing valve is installed in-line. It is responsible for maintaining the downstream line pressure to the pressure set at
More informationDiaphragm pressure gauge guard MDM 902
Diaphragm pressure gauge guard MDM 90 Nominal size DN 0 5 Pressure PN 10 bar Features Pressure measurement up to 10 bar EPDM diaphragm with PTFE coating on the side in contact with the medium Reliable
More informationPressure relief valve
Pressure relief valve Operating manual Series DHV 718 Version BA-2016.01.11 EN Print-No. 300 524 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationPressure relief valve
Pressure relief valve Operating manual Series DHV 712 R Version BA-2016.01.19 EN Print-No. 300 472 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationInstruction presentation Special valves
Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and
More informationSTAINLESS STEEL OVERFLOW VALVE TYPE 417
MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence
More informationTechnical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3
Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling
More informationModular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001
Modular valve block Operating manual Series MVB 100/200 Version BA-2016.04.20 EN Print-No. 300 627 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationType overview. R B2 en-gb subject to changes 1
Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationInstallation and Operating Instructions Bypass Flow Meter DST
Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationMounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)
Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Type 42-10 RS Check Valve (backflow protection) Mounting and Operating Instructions EB 3009 EN Edition December 2015 Definition
More informationFlowmeter. Original operating manual DFM
Flowmeter Original operating manual Series DFM 165 350 Version BA-2016.08.09 EN Print-No. 300 458 TR MA DE Rev002 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationDifferential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN
Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationSeries 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve
Series Self-operated Pressure Regulators Type -6 B Excess Pressure Valve Application Set points from 0.2 to 20 bar with valves G ½, G ¾, and G as well as DN, DN 2, DN 0, and DN 0 Nominal pressure PN 2
More informationProducts no longer available
Technical data sheet R2.. Characterized control valves, 2-way, with internal thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationSafety Relief Valve HON 832
Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class
More informationDiaphragm relief valve
Product: Diaphragm relief valve Type: 620.10 622.10 623.10 624.10 625.10 626.10 627.10 Please state here the exact type and serial number of your diaphragm relief valve. (can be read off the type plate
More informationRp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]
Technical data sheet C2..QP-.. For closed cold and warm water systems For modulating control of airhandling and heating systems on the water side Snap-assembly of the actuator overview DN [ ] Vnom [ l/h]
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationDiaphragm Pressure Keeping Valve
Product: Diaphragm pressure keeping valve Type: 620.D 622.D 623.D 624.D 625.D 626.D 627.D Please state here the exact type and serial number of your diaphragm pressure keeping valve. (can be read off the
More informationITT RICHTER CHEMIE-TECHNIK
ITT RICHTER CHEMIE-TECHNIK The Answer to Corrosion Series MV/MVP Operating Manual for Diaphragm Valves Contents 1 General 2 Safety 3 Transport and storage 4 Product description 5 Installation 6 Operation
More informationDifferential pressure controller (PN 16) AHP - return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use
More informationAVP-F. p setting range (bar) Code No. 003H6200
Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator
More informationSeries 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version
Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure
More informationAutomatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN
Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined
More informationOverflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.
Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationSteam Trap BK 15 (DN40, DN 50) Original Installation Instructions English
Steam Trap BK 15 (DN40, DN 50) EN English Original Installation Instructions 810682-03 1 Contents Page Important Notes Usage for the intended purpose... 4 Safety note... 4 Danger... 4 Attention... 4 Application
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationNeotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions
Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious
More informationPressure independent control valve (PICV) FLOWMATIC
Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationTwo-port valves, male threaded, PN25
4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationSTAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves
STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance
More informationPrecision pressure regulators LRP/LRPS
Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement
More informationInstallation, operation & maintenance manual - original version
Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018
More informationOverview of types. Technical data. Safety notes
Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and
More informationSeries 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version
Series 44 Self-operated Pressure Regulators Type 44-1 B Pressure Reducing Valve Type 44-6 B Excess Pressure Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)
Self-operated Pressure Regulators Type 42-20 Type 42-25 Differential Pressure Regulators (opening) Translation of original instructions Type 42-20 Differential Pressure Regulator Type 42-25 Differential
More informationDiaphragm Valve, Metal
Diaphragm Valve, Metal Construction The EMÜ pneumatically operated 2/2-way diaphragm valve has a low maintenance membrane actuator which can be controlled by inert gaseous media. Features Suitable for
More informationTECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS
TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS THE COMPANY ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationOverflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationTECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS
TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48
More informationSteam Trap BK BK 212-ASME. Original Installation Instructions English
Steam Trap BK 212.. BK 212-ASME EN English Original Installation Instructions 810609-02 1 Contents Page Important Notes Usage for the intended purpose... 3 Safety note... 3 Danger... 3 Attention... 3 Application
More informationRegulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Regulating valves Type REG 6-65 Type REG-SS 15-40 REFRIGERATION AND AIR CONDITIONING Technical leaflet Content Page Introduction........................................................................................3
More informationInstallation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E
Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified
More informationBladder Damper PP/PVC
Operating instructions Bladder Damper PP/PVC EN Please carefully read these operating instructions before use. Do not discard. The operator shall be liable for any damage caused by installation or operating
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationBall Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
More informationPressure Reducing Valve for Steam Type 2333 A
Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with
More informationHAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings
More informationSelf Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)
Serial No. H-V063-E-9 Self Control Valves Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186) Contents 1. Be sure to read the following warranty clauses of our
More informationMAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.
MAKING MODERN LIVING POSSIBLE Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION Technical leaflet Contents Page Introduction...3 Features...3 Design...4 Technical
More informationMeasurement of Low GAS & Liquid Flows
Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More information3-port seat valves with externally threaded connection, PN 16
4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1
More informationMounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6
Series 43 Temperature Regulators Type 43-5 and Type 43-7 Type 43-6 Type 43-6 Type 43-7 with flanged valve body, DN 32 to 50 Type 43-5 Type 43-7 with welding ends Mounting and Operating Instructions EB
More informationUniversal Charging and Testing Unit FPU-1
1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose
More informationSerie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY
Swing wafer check valve BRANDONI made in E U R O P E Application fields WATER CONDITIONING INDUSTRY HEATING 38 www.brandoni.it The valves in series 06 are swing wafer check valves, manufactured in accordance
More informationTA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics
TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative
More informationInstruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X
Standard Surge Eliminator Standard 104052 - X Flushable 104053 - X - X Page 2 of 16 Issue: 2.3 Index Section 1.1 General Description 1.2 Operating Principle 1.3 Specification 1.4 Fitting Selection - Standard
More informationTA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)
Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) IMI TA / Control valves / The pressure independent balancing and control valve ensures
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationHigh Performance BSP Dial Up Pattern Pressure Reducing Valve
See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed
More informationBTV. Internally threaded 2-way control valve. Flow characteristics. Function
Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationBall valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001
Ball valve Operating instructions for series Version BA-2016.02.05 Print-No. 300 587 TR MA DE Rev001 We reserve the right to make technical changes. Read carefully before use. Save for future use. ASV
More informationControl Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English
Control Valve with ZK Radial Stage Nozzle ZK 210 EN English Original Installation Instructions 810691-00 Contents Important Notes Page Usage for the Intended Purpose... 3 Safety Note... 3 Warning... 4
More informationOPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More information2-port and 3-port seat valves, PN16
s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More information