STRAIGHT CONNECTOR 5 80 N N N N N N N. Copyright 2016 by K-net All Rights Reserved

Size: px
Start display at page:

Download "STRAIGHT CONNECTOR 5 80 N N N N N N N. Copyright 2016 by K-net All Rights Reserved"

Transcription

1 STRAIGHT CONNECTOR The Push-fit straight connectors make splicing microduct fast and easy. Simply push the microduct into the center of the connector. No tools are required. The connector can be connected and disconnected 10 times and still maintain the high performance requirement for air-blown installation systems. Microduct connector operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 bar. For Tubing Type: PE, PU, Nylon, Polyurethane Burst Pressure: > 25bar Push-fit test: Pass Hydraulic pressure test: Pass(Resisting at 13 bar for 2 minutes)

2 END CAP To Keep Microduct networks free of debris, seal the system with Push-Fit Endcaps. With the same functionality as the Push-Fit Connectors, installation simply involves pushing the Microduct into the Endcap. It can be attached and removed 10 times while still maintaining the same high performance characteristics. Push-Fit Microduct endcap operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. quick Burst rating is 25 bar. Burst Pressure: BT MA 321 High Pressure Performance hydraulic pressure test: Pass(Resisting at 13.5kgf/ cm2 for 2 minutes.) Burst Pressure: > 25bar Water Immersion test: Pass (Water proof)

3 DBL CONNECTOR, END CAP The direct burial endcap is used in access network where the direct buried thick walled microduct is sealed to keep microduct networks free of debris and moisture. With the same functionality as the connectors, installation simply involves pushing the microduct into the endcap. Material: HDPE Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years

4 REDUCING CONNECTOR The Push-fit reducing connector make splicing microduct fast and easy. Simply push the microducts into the center of the connector. No tools are required. The reducers can be connected and disconnected 10 times and still maintain the high performance requirements for air blown installation systems. Microduct reducing connector operates at 15 BAR (218 psi) with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 BARS (363 psi). Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years hydraulic pressure test: Resisting at 13.5kgf/ cm2 for 2 minutes

5 GAS-BLOCK CONNECTOR Gas block microduct connectors normally used between indoor and outdoor environments to prevent air fow that may result in condensed water getting into in ducts. After cable installation, the connector can be gas sealed by Pushing the connector ends together. This version is intended for 7mm to 14mm thick walled ducts. Technical Specifications Material: Body PC, impact resistant Collect POM, Stainless steel teeth O-rings Nitrile rubber, Cable size(mm) 7mm ( 1-4.6mm cable) 10mm (5-8mm cable) 12mm (3-6mm cable) 12mm (5-8mm cable) 12mm (7-10mm cable 14mm ( 3-6mm cable) 14mm (7-10mm cable) 14 (9-12mm cable) 14mm GasBlock Connector Blowing Pressure: Between temperatures of -10 and +60, all connectors size can be used for blowing operations at pressures up to 16bar. Burst Pressure: > 26bar Gas Tightness: Leakage at 16 bar gas pressure: 1ml/minute approx Leakage at 0.7bar gas pressure: 0.1ml/minute approx Water ingress: The connectors shall seal against a 6m head of water. Insertion force: 50N max (5kg) Retention force: 55N min (5mm m/d) 135N min (12mm m/d) 155N min (14mm m/d) (collect not held in)

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12 PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN

More information

C 0G 00 N/US

C 0G 00 N/US G, GP, G, GP In-line flow regulators (block form) Uni-directional Ø /... / inch, Ø 4... mm High flow performance In-line or panel mounting Adjustment can be locked aptive regulator needle will not blow

More information

The Push-fit Solution for Blown Fibre & Cable Systems

The Push-fit Solution for Blown Fibre & Cable Systems The Push-fit Solution for Blown Fibre & Cable Systems January 2017 Quality Manufacture The John Guest Group has a long established reputation as a world leading manufacturer of push-fit fittings, tube

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

P/N for 1.25" SDR P/N for 1.50" SDR P/N for 2.00" SDR

P/N for 1.25 SDR P/N for 1.50 SDR P/N for 2.00 SDR CABLE OVERBLOWING JUNCTION BOX OPERATION & MAINTENANCE MANUAL P/N 89066 for 1.25" SDR P/N 89067 for 1.50" SDR P/N 89068 for 2.00" SDR Copyright 2017 by All rights reserved. No part of this publication

More information

Instruments AQDC. Aluminium Quick Disconnects. Light-weight, quick and reliable method a making a number of pneumatic connections.

Instruments AQDC. Aluminium Quick Disconnects. Light-weight, quick and reliable method a making a number of pneumatic connections. AQDC Aluminium Quick Disconnects Instruments Light-weight, quick and reliable method a making a number of pneumatic connections. 8, 16, 24 and 32 port stainless steel quick disconnects. Available with

More information

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500 Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications

More information

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SEALED CONNECTORS FOR THE LIMIT SWITCHES SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

Water Fittings & Hose

Water Fittings & Hose Connector Plugs A d1 d R H Male Type Brass Part R Di H A Number Series BSPT CM251 1/8 9 17 22 25 200 CM252 Series 1/4 9 19 26 29 1/4 Flow CM253 3/8 9 19 30 30 CM351 1/8 13 25 26 35 CM352* 300 1/4 13 25

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Protected Microducts, Overview and Current Trends

Protected Microducts, Overview and Current Trends Draka Comteq Netherlands / Comparison of Microduct Types for optical cables installation Protected Microducts, Overview and Current Trends W. Griffioen 1, W. Greven 2 1 Draka Comteq Cable Solutions, Amsterdam,

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION The Scott Safety ELSA Muster is a positive pressure escape set providing air on demand for situations where the escape route may require a lot of physical

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT MODEL 862-000-200 ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT DOCUMENT NO. 430-007H September 20, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY

More information

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to RV* FH1 G G B FH Specifications Descriptions Cylinder bore size Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke length Rod diameter Capacity of

More information

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

TEK-SUB 4800B. Submersible Level Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter

More information

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................

More information

Coiling Tube with Twist-Proof Fitting

Coiling Tube with Twist-Proof Fitting http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem

More information

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500 Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality

More information

Sirocco Equipment Spares & Accessories

Sirocco Equipment Spares & Accessories Sirocco Equipment Spares & Accessories Prysmian Part Number: See Individual Descriptions 2 & 4 Fibre Guide Part No. XBFSC00056 Used in the Sirocco Blowing Head when installing either 2 or 4 fibre units.

More information

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875

More information

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of

More information

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET

More information

Pressure Injection Cell Operator s Manual

Pressure Injection Cell Operator s Manual Pressure Injection Cell Operator s Manual Operator s Manual Pressure Injection Cell CONGRATULATIONS! Congratulations on your purchase of a Next Advance Pressure Injection Cell. Please read this operator

More information

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications RV* FH1 G B FH G A S Specifications Descriptions Size Cylinder bore size mm Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

SERIES A24 RAISED RIB

SERIES A24 RAISED RIB SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance

More information

PLT LINE THROWER RESTECH NORWAY AS USERS MANUAL RESCUE 230

PLT LINE THROWER RESTECH NORWAY AS USERS MANUAL RESCUE 230 USERS MANUAL RESCUE 230 COMPLIES WITH SOLAS 74/83 0575/05 RESTECH NORWAY AS P.O.Box 624, N-8001 Bodø, Norway +47 7554 2440 +47 7554 2441 E-mail: restech@restech.no Web: www.restech.no 1 !! WARNINGS!! THIS

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 / Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply

More information

Aquashield to Mitigate Water Ingress of Gas Pipes

Aquashield to Mitigate Water Ingress of Gas Pipes IGEM Young Persons Paper Competition 2017 Aquashield to Mitigate Water Ingress of Gas Pipes Assistant Engineer Technical Development Section, Distribution Operation Department The Hong Kong and China Gas

More information

Clean Speed Controller with One-touch Fitting

Clean Speed Controller with One-touch Fitting Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.

More information

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling Pressure Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling WIKA data sheet PM 02.22 for further approvals see page 3 Applications

More information

Baseline Two-Wire Technology

Baseline Two-Wire Technology Baseline Two-Wire Technology Baseline s bicoders work with Baseline s biline two-wire technology to create the only true bi-direc onal two-wire devices in the industry. Baseline s bicoders not only receive

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

Pressure switch and Thermostat CAS

Pressure switch and Thermostat CAS Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to

More information

RS5 & RS6 Rescue Sled. Product Manual

RS5 & RS6 Rescue Sled. Product Manual RS5 & RS6 Rescue Sled Product Manual 1 Index Technical data / Capacity Parts List Materials List Operational Instructions Packing Storage Maintenance & Test Procedures Repairs 3 4 5 6 9 9 10 11 WARNING:

More information

The second stage cannot begin until the first stage is complete.

The second stage cannot begin until the first stage is complete. Addendum to Pneumatic Corker (August 12, 2002) Please read the Operating Instructions before using the pneumatic corker. The purpose of this addendum is three-fold. 1) Describe in more detail how the corker

More information

Shut-off ball valve Type GBC

Shut-off ball valve Type GBC Data sheet Shut-off ball valve GBC shut-off ball valves, type GBC, are manually operated shut-off valves suitable for bi-directional flow. The GBC valves are used in liquid, suction and hotgas lines in

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060 Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Table of Contents Want full page pictures with most important parts labeled in the beginning. 1 Table of Contents Want full page pictures with most important parts labeled in the beginning. Precool Procedures (Perform before cooling down): 1. Check N2 and 4He gas tanks to be sure that there is

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Push-In Fitting Type with Stop Valve

Push-In Fitting Type with Stop Valve http://www.pisco.co.jp Push-In Fitting Type with Stop Valve 278 Push-In Fitting Type with Stop Valve for General Pneumatic Piping. Air Stop by Tube Disconnection. Easy Insertion and Disconnection by Double-passage

More information

AIR STAPLER MODEL: CSG1C Part No

AIR STAPLER MODEL: CSG1C Part No AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm

More information

User s Guide. CO2 & O2 Controller for miniature incubators

User s Guide. CO2 & O2 Controller for miniature incubators CO2 O2 Control User s Guide CO2 & O2 Controller for miniature incubators Precise CO2 & O2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for

More information

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 Pressure Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 WIKA data sheet DS 95.18 Applications Chemical/petrochemical industry, oil/gas industries

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TBV-CM. Combined control & balancing valves for small terminal units For modulating control TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the

More information

VEP Series VEP-BOP Series. canada.dixonvalve.com Customer Service:

VEP Series VEP-BOP Series. canada.dixonvalve.com Customer Service: UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFAC VEP Series VEP-BOP Series Customer Service: 877.963.4966 Body Technical Specifications Pressure Rating Burst

More information

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use CAT.ES20-19 A Speed Controller with One-touch Fitting for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ Speed controllers for clean room use AS-FPQ: Brass (electroless nickel plated) and

More information

Data Sheet. Vacuum generators

Data Sheet. Vacuum generators Data Pack G Issued March 1997 1502323721 Data Sheet Vacuum generators Specifications Fluid Air perating pressure range 2.5~6kgf/cm 2 Max. operating pressure 7kgf/cm 2 perating temperature range 5~60 C

More information

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Picture. Minimum cable bending radius 100 mm [4] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables) Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure The flow-shut mechanism will operate to stop the air flow when the tube is disconnected and will allow air flow when the tube is connected. The double-passage structure facilitates easy connection and

More information

Push-in fittings QB, NPT

Push-in fittings QB, NPT General technical data Connecting thread UNF NPT Size Standard Design Push-pull principle Mounting position An Tpe of seal on threaded plug Sealing ring Coating Operating and environmental conditions Operating

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Experiment 13: Make-Up Lab for 1408/1420

Experiment 13: Make-Up Lab for 1408/1420 Experiment 13: Make-Up Lab for 1408/1420 This is only for those that have approval. Students without approval will not be allowed to perform the lab. The pre-lab must be turned in at the beginning of lab.

More information

World Area Differences Technical Information

World Area Differences Technical Information World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National

More information

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS AIR STAPLER MODEL: CSG3KC Part No. 3110380 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.4 cfm

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

APTUM AB PRICELIST. Prisliste ekster. Undergruppe. Name and description

APTUM AB PRICELIST. Prisliste ekster. Undergruppe. Name and description Produktgruppe Undergruppe Strukturvare 1000 PLT Launching unit without air cylinder and cover 22 475,00 Launching Unit without air cylinder and cover. 1005 PLT Launching unit 33 378,00 Launching Unit with

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

MPM426W/436W Submersible Level Transmitter

MPM426W/436W Submersible Level Transmitter /436W Submersible Level Transmitter Features Full sealed stainless steel construction for submersible part; sensor and amplifier circuit are all in the sealed housing; protection class IP68; Aluminum-alloy

More information

WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468

WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468 Hull Picture Art.. (pipe) or combination Splash guard Stream resistance * Wind tolerance Temperature level of mounting surface Size and hight (mm) Sealable WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467,,

More information

Pressure Sensing Valve - Model 4023

Pressure Sensing Valve - Model 4023 Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

K&B Vault and Riser Closures

K&B Vault and Riser Closures K&B Vault and Riser Closures K&B Vault Closures K&B Closures are strong, lightweight, and protect a wide variety of vault splice configurations with an air and water tight seal. K&B closures offer a full

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

G7S Hand Pump Owner s Manual

G7S Hand Pump Owner s Manual G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure

More information

Push-in fittings CQ, for push-fit piping systems

Push-in fittings CQ, for push-fit piping systems Key features General information Suitable for polyamide pipes PQ-PA and aluminium pipes PQ-AL O.D. 12, 15, 18, 22 and 28 mm Internet: pq Suitable for polyamide tubing PAN and polyurethane tubing PUN O.D.

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

aeration and mixing systems

aeration and mixing systems 1 air diffusers The Zenit range includes both disc and tube membrane air diffusers. Both models are fitted with high-quality membranes with perforation ensuring high oxygen transfer with low headloss.

More information

Pressure regulating valves Types OFV, OFV-SS

Pressure regulating valves Types OFV, OFV-SS Data sheet Pressure regulating valves Types OFV, OFV-SS OFV are angle-way pressure regulating valves, which have ajustable opening pressure and cover the differential pressure range ( P): 2-8 bar (29 116

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection

More information

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09 PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,

More information

with self-sealing gas valve system

with self-sealing gas valve system with self-sealing gas valve system R DUCTILE PVC POLSAFE GAS DISTRIBUTION SYSTEM INTRODUCTION POLSAFE is a programme of fittings for low pressure gas distribution systems. POLSAFE is designed for 25 up

More information

Prestolok PLS Stainless Steel Push-to-Connect Fittings

Prestolok PLS Stainless Steel Push-to-Connect Fittings Prestolok PS Stainless Steel Push-to-Connect ittings Parker s Prestolok PS fittings are ideal for conveying corrosive fluids in aggressive environments. Prestolok PS fittings provide corrosion resistance

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style Finger Valve eriesvhk Large effective area: to mm 2 mall knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Pneumatic retractable fitting for simple commercially available control units or process applications

Pneumatic retractable fitting for simple commercially available control units or process applications Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced

More information