1 STRAIGHT CONNECTOR The Push-fit straight connectors make splicing microduct fast and easy. Simply push the microduct into the center of the connector. No tools are required. The connector can be connected and disconnected 10 times and still maintain the high performance requirement for air-blown installation systems. Microduct connector operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 bar. For Tubing Type: PE, PU, Nylon, Polyurethane Burst Pressure: > 25bar Push-fit test: Pass Hydraulic pressure test: Pass(Resisting at 13 bar for 2 minutes)
2 END CAP To Keep Microduct networks free of debris, seal the system with Push-Fit Endcaps. With the same functionality as the Push-Fit Connectors, installation simply involves pushing the Microduct into the Endcap. It can be attached and removed 10 times while still maintaining the same high performance characteristics. Push-Fit Microduct endcap operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. quick Burst rating is 25 bar. Burst Pressure: BT MA 321 High Pressure Performance hydraulic pressure test: Pass(Resisting at 13.5kgf/ cm2 for 2 minutes.) Burst Pressure: > 25bar Water Immersion test: Pass (Water proof)
3 DBL CONNECTOR, END CAP The direct burial endcap is used in access network where the direct buried thick walled microduct is sealed to keep microduct networks free of debris and moisture. With the same functionality as the connectors, installation simply involves pushing the microduct into the endcap. Material: HDPE Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years
4 REDUCING CONNECTOR The Push-fit reducing connector make splicing microduct fast and easy. Simply push the microducts into the center of the connector. No tools are required. The reducers can be connected and disconnected 10 times and still maintain the high performance requirements for air blown installation systems. Microduct reducing connector operates at 15 BAR (218 psi) with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 BARS (363 psi). Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years hydraulic pressure test: Resisting at 13.5kgf/ cm2 for 2 minutes
5 GAS-BLOCK CONNECTOR Gas block microduct connectors normally used between indoor and outdoor environments to prevent air fow that may result in condensed water getting into in ducts. After cable installation, the connector can be gas sealed by Pushing the connector ends together. This version is intended for 7mm to 14mm thick walled ducts. Technical Specifications Material: Body PC, impact resistant Collect POM, Stainless steel teeth O-rings Nitrile rubber, Cable size(mm) 7mm ( 1-4.6mm cable) 10mm (5-8mm cable) 12mm (3-6mm cable) 12mm (5-8mm cable) 12mm (7-10mm cable 14mm ( 3-6mm cable) 14mm (7-10mm cable) 14 (9-12mm cable) 14mm GasBlock Connector Blowing Pressure: Between temperatures of -10 and +60, all connectors size can be used for blowing operations at pressures up to 16bar. Burst Pressure: > 26bar Gas Tightness: Leakage at 16 bar gas pressure: 1ml/minute approx Leakage at 0.7bar gas pressure: 0.1ml/minute approx Water ingress: The connectors shall seal against a 6m head of water. Insertion force: 50N max (5kg) Retention force: 55N min (5mm m/d) 135N min (12mm m/d) 155N min (14mm m/d) (collect not held in)
PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12
PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN
More informationC 0G 00 N/US
G, GP, G, GP In-line flow regulators (block form) Uni-directional Ø /... / inch, Ø 4... mm High flow performance In-line or panel mounting Adjustment can be locked aptive regulator needle will not blow
More informationThe Push-fit Solution for Blown Fibre & Cable Systems
The Push-fit Solution for Blown Fibre & Cable Systems January 2017 Quality Manufacture The John Guest Group has a long established reputation as a world leading manufacturer of push-fit fittings, tube
More informationIAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard
More informationP/N for 1.25" SDR P/N for 1.50" SDR P/N for 2.00" SDR
CABLE OVERBLOWING JUNCTION BOX OPERATION & MAINTENANCE MANUAL P/N 89066 for 1.25" SDR P/N 89067 for 1.50" SDR P/N 89068 for 2.00" SDR Copyright 2017 by All rights reserved. No part of this publication
More informationInstruments AQDC. Aluminium Quick Disconnects. Light-weight, quick and reliable method a making a number of pneumatic connections.
AQDC Aluminium Quick Disconnects Instruments Light-weight, quick and reliable method a making a number of pneumatic connections. 8, 16, 24 and 32 port stainless steel quick disconnects. Available with
More informationDigital pressure gauge Model CPG500
Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationTECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS
TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications
More informationSEALED CONNECTORS FOR THE LIMIT SWITCHES
SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications
More informationSIMPLAIR PIPING TOOL. JXT Company
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationWater Fittings & Hose
Connector Plugs A d1 d R H Male Type Brass Part R Di H A Number Series BSPT CM251 1/8 9 17 22 25 200 CM252 Series 1/4 9 19 26 29 1/4 Flow CM253 3/8 9 19 30 30 CM351 1/8 13 25 26 35 CM352* 300 1/4 13 25
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationProtected Microducts, Overview and Current Trends
Draka Comteq Netherlands / Comparison of Microduct Types for optical cables installation Protected Microducts, Overview and Current Trends W. Griffioen 1, W. Greven 2 1 Draka Comteq Cable Solutions, Amsterdam,
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationTECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS
ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION The Scott Safety ELSA Muster is a positive pressure escape set providing air on demand for situations where the escape route may require a lot of physical
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationMODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT
MODEL 862-000-200 ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT DOCUMENT NO. 430-007H September 20, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY
More informationPosition locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to
RV* FH1 G G B FH Specifications Descriptions Cylinder bore size Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke length Rod diameter Capacity of
More informationTEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL
Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter
More informationOverflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................
More informationCoiling Tube with Twist-Proof Fitting
http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem
More informationDigital pressure gauge Model CPG500
Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality
More informationSirocco Equipment Spares & Accessories
Sirocco Equipment Spares & Accessories Prysmian Part Number: See Individual Descriptions 2 & 4 Fibre Guide Part No. XBFSC00056 Used in the Sirocco Blowing Head when installing either 2 or 4 fibre units.
More informationMODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT
MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875
More informationAIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB
Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More informationPressure Injection Cell Operator s Manual
Pressure Injection Cell Operator s Manual Operator s Manual Pressure Injection Cell CONGRATULATIONS! Congratulations on your purchase of a Next Advance Pressure Injection Cell. Please read this operator
More informationCKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications
RV* FH1 G B FH G A S Specifications Descriptions Size Cylinder bore size mm Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationSERIES A24 RAISED RIB
SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance
More informationPLT LINE THROWER RESTECH NORWAY AS USERS MANUAL RESCUE 230
USERS MANUAL RESCUE 230 COMPLIES WITH SOLAS 74/83 0575/05 RESTECH NORWAY AS P.O.Box 624, N-8001 Bodø, Norway +47 7554 2440 +47 7554 2441 E-mail: restech@restech.no Web: www.restech.no 1 !! WARNINGS!! THIS
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More information/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651
/ Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply
More informationAquashield to Mitigate Water Ingress of Gas Pipes
IGEM Young Persons Paper Competition 2017 Aquashield to Mitigate Water Ingress of Gas Pipes Assistant Engineer Technical Development Section, Distribution Operation Department The Hong Kong and China Gas
More informationClean Speed Controller with One-touch Fitting
Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.
More informationBourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling
Pressure Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling WIKA data sheet PM 02.22 for further approvals see page 3 Applications
More informationBaseline Two-Wire Technology
Baseline Two-Wire Technology Baseline s bicoders work with Baseline s biline two-wire technology to create the only true bi-direc onal two-wire devices in the industry. Baseline s bicoders not only receive
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationFTC130 Transmitter. Operating Manual
Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationRS5 & RS6 Rescue Sled. Product Manual
RS5 & RS6 Rescue Sled Product Manual 1 Index Technical data / Capacity Parts List Materials List Operational Instructions Packing Storage Maintenance & Test Procedures Repairs 3 4 5 6 9 9 10 11 WARNING:
More informationThe second stage cannot begin until the first stage is complete.
Addendum to Pneumatic Corker (August 12, 2002) Please read the Operating Instructions before using the pneumatic corker. The purpose of this addendum is three-fold. 1) Describe in more detail how the corker
More informationShut-off ball valve Type GBC
Data sheet Shut-off ball valve GBC shut-off ball valves, type GBC, are manually operated shut-off valves suitable for bi-directional flow. The GBC valves are used in liquid, suction and hotgas lines in
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationCompact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT
Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationProduct Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060
Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationTable of Contents Want full page pictures with most important parts labeled in the beginning.
1 Table of Contents Want full page pictures with most important parts labeled in the beginning. Precool Procedures (Perform before cooling down): 1. Check N2 and 4He gas tanks to be sure that there is
More informationPegas 4000 MF Gas Mixer InstructionManual Columbus Instruments
Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads
TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationPush-In Fitting Type with Stop Valve
http://www.pisco.co.jp Push-In Fitting Type with Stop Valve 278 Push-In Fitting Type with Stop Valve for General Pneumatic Piping. Air Stop by Tube Disconnection. Easy Insertion and Disconnection by Double-passage
More informationAIR STAPLER MODEL: CSG1C Part No
AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm
More informationUser s Guide. CO2 & O2 Controller for miniature incubators
CO2 O2 Control User s Guide CO2 & O2 Controller for miniature incubators Precise CO2 & O2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for
More informationDiaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34
Pressure Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 WIKA data sheet DS 95.18 Applications Chemical/petrochemical industry, oil/gas industries
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationVEP Series VEP-BOP Series. canada.dixonvalve.com Customer Service:
UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFAC VEP Series VEP-BOP Series Customer Service: 877.963.4966 Body Technical Specifications Pressure Rating Burst
More informationSeries AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use
CAT.ES20-19 A Speed Controller with One-touch Fitting for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ Speed controllers for clean room use AS-FPQ: Brass (electroless nickel plated) and
More informationData Sheet. Vacuum generators
Data Pack G Issued March 1997 1502323721 Data Sheet Vacuum generators Specifications Fluid Air perating pressure range 2.5~6kgf/cm 2 Max. operating pressure 7kgf/cm 2 perating temperature range 5~60 C
More informationPicture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
More informationOverflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationCautions : 1. Be careful when you release the Stop Fitting with some internal pressure
The flow-shut mechanism will operate to stop the air flow when the tube is disconnected and will allow air flow when the tube is connected. The double-passage structure facilitates easy connection and
More informationPush-in fittings QB, NPT
General technical data Connecting thread UNF NPT Size Standard Design Push-pull principle Mounting position An Tpe of seal on threaded plug Sealing ring Coating Operating and environmental conditions Operating
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationExperiment 13: Make-Up Lab for 1408/1420
Experiment 13: Make-Up Lab for 1408/1420 This is only for those that have approval. Students without approval will not be allowed to perform the lab. The pre-lab must be turned in at the beginning of lab.
More informationWorld Area Differences Technical Information
World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National
More informationAIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS
AIR STAPLER MODEL: CSG3KC Part No. 3110380 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.4 cfm
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationAPTUM AB PRICELIST. Prisliste ekster. Undergruppe. Name and description
Produktgruppe Undergruppe Strukturvare 1000 PLT Launching unit without air cylinder and cover 22 475,00 Launching Unit without air cylinder and cover. 1005 PLT Launching unit 33 378,00 Launching Unit with
More informationCV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.
DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,
More informationO.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA
HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationMPM426W/436W Submersible Level Transmitter
/436W Submersible Level Transmitter Features Full sealed stainless steel construction for submersible part; sensor and amplifier circuit are all in the sealed housing; protection class IP68; Aluminum-alloy
More informationWALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468
Hull Picture Art.. (pipe) or combination Splash guard Stream resistance * Wind tolerance Temperature level of mounting surface Size and hight (mm) Sealable WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467,,
More informationPressure Sensing Valve - Model 4023
Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationK&B Vault and Riser Closures
K&B Vault and Riser Closures K&B Vault Closures K&B Closures are strong, lightweight, and protect a wide variety of vault splice configurations with an air and water tight seal. K&B closures offer a full
More informationOPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS
OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:
More informationG7S Hand Pump Owner s Manual
G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure
More informationPush-in fittings CQ, for push-fit piping systems
Key features General information Suitable for polyamide pipes PQ-PA and aluminium pipes PQ-AL O.D. 12, 15, 18, 22 and 28 mm Internet: pq Suitable for polyamide tubing PAN and polyurethane tubing PUN O.D.
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationLMU100/200 Series. Standard Specifications
Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient
More informationaeration and mixing systems
1 air diffusers The Zenit range includes both disc and tube membrane air diffusers. Both models are fitted with high-quality membranes with perforation ensuring high oxygen transfer with low headloss.
More informationPressure regulating valves Types OFV, OFV-SS
Data sheet Pressure regulating valves Types OFV, OFV-SS OFV are angle-way pressure regulating valves, which have ajustable opening pressure and cover the differential pressure range ( P): 2-8 bar (29 116
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style
Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection
More informationPRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09
PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,
More informationwith self-sealing gas valve system
with self-sealing gas valve system R DUCTILE PVC POLSAFE GAS DISTRIBUTION SYSTEM INTRODUCTION POLSAFE is a programme of fittings for low pressure gas distribution systems. POLSAFE is designed for 25 up
More informationPrestolok PLS Stainless Steel Push-to-Connect Fittings
Prestolok PS Stainless Steel Push-to-Connect ittings Parker s Prestolok PS fittings are ideal for conveying corrosive fluids in aggressive environments. Prestolok PS fittings provide corrosion resistance
More informationWK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION
2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style
Finger Valve eriesvhk Large effective area: to mm 2 mall knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationPneumatic retractable fitting for simple commercially available control units or process applications
Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced
More information