Multiple port vessels.
|
|
- Cordelia Irene Reeves
- 6 years ago
- Views:
Transcription
1 INTRODUCTION Multiple port vessels. Hydraulic design of side-ported RO vessel arrangements (How to get the best out of the side-ported vessels) This document has the final target to show the best multiport hydraulic arrangement in skids. However, the reader has to bear in mind that the following document it is only a recommendation and every case must be studied in depth in order to reach the best configuration, and we cannot avoid the economical point of the issue. In every installation, we should bear in mind both terms Technical VS Economical in order to reach a point of optimization which let us be competitive in our bids. The reader must consider this document as an initial guideline to get the best technical solution, but normally the best technical solution implies a higher cost. Based on the experience of many years in this kind of applications, from our technical department BEL can offer our clients our support and our fully disposition to study the best configuration, considering the economical & technical terms, in order to give you the most attractive solution for your end users. HYDRAULIC DESIGN OF SIDE-PORTED RO VESSEL ARRANGEMENTS Generally any RO vessels arrangement has two primary elements: the vessel row and the pipe manifolds (Fig.1) Fig. 1 - Basic side-ported RO vessels arrangement elements Page 1 of 8
2 From hydraulics point of view the side-ported vessels and pipe manifolds may be connected in a number of ways (Fig.2) Fig.2 - Hydraulic classification of the side-ported vessels and pipe manifolds connections (in clockwise direction): 1. S-type row; 2. U-type row; 3. S-type manifold; 4. U-type manifold; In the S-type row of vessels the feed inlet and brine outlet for the row are in the opposite vessels. For U-type row the feed inlet and the brine outlet are in the same vessel. The former type is rarely used. The S-type and U-type manifold arrangements consider the feed and brine streams distribution to the vessel rows and collection from the rows. In the S-type manifold connection to the vessel rows the feed and brine streams in the dividing and collecting manifolds are in the same direction. In the U-type manifold connection the afore-mentioned streams are in opposite directions (Fig.2). In designing the vessel arrangement three hydraulic phenomena shall be taken into account: 1. Pressure losses in connections of vessels and manifolds, 2. The feed flow maldistribution between the vessels in the same row, 3. The feed flow maldistribution between the vessel rows connected to the same dividing and collecting manifolds. The pressure losses in the feed and brine streams have direct effect on the process energy consumption and productivity. They can t be neglected even at the preliminary design stage of the RO desalination unit as the loss in production may be surprisingly high up to 3 8%. The flow maldistribution may be measured by the ratio of minimum flow rate of the feed trough the vessel to the feed flow maximum value. For example, in the U-type row the first vessel accepts the maximum fed flow, while the vessel farthest from the manifold receives the minimum flow. In the U-type manifold the picture is quite the opposite: the row nearest to the inlet receives the minimum feed flow rate. This behavior is inherent and has a theory-grounded explanation. In a dividing manifold, the flow diverted to the vessel causes the main stream to decelerate and its static pressure to increase stepwise. Thus, the pressure drop across the vessel row increases progressively with its distance from the inlet. This results in hydraulic non-uniformity with the maximum flow in the row farthest from the manifold inlet. In a combining manifold, the velocity in the main stream increases as the branch streams from the vessel rows progressively merge into it. It causes the static pressure in the manifold to drop downstream, its minimum being at the manifold outlet. Minimum and maximum Page 2 of 8
3 pressure areas in both manifolds define extreme flows through the vessels. Generally the S-type manifolds perform better than the U-type ones. The feed flow maldistribution results in the recovery maldistribution working in the opposite direction; the higher the flow rate the lower the recovery. Fig. 3 gives fair indication of the predicted maldistribution effect in a row containing 6 vessels. Two cases are compared the 2-inch and 3-inch side ports for feed and brine. Fig.3 - The vessel feed flow rate and membrane recovery maldistribution in the U-type row for seawater of 62 Bar, at the maximum permeate flux of 27 l/(m2*h), recovery of 45%, and fouling of 80%. In hydraulically faulty designs the flow maldistribution may reach 15% (abs), the maximum recovery maldistribution being below 5%. It leads to a less effective usage of the RO membranes and shortens their life. To limit the extents of the in-row maldistribution phenomenon the maximum number of vessels in a row shall be limited to the figures given in Table 1 Table 1 - Maximum number of vessels in a single row* port size Sea Water Brackish Water NOTE*- These table shows theoretical values, but every single case should be study, mainly because the sizing of ports will depend on the flows of the systems. Page 3 of 8
4 For brackish water desalination at the recovery above 65% the brine discharge connection size may be reduced as compared to the feed connection size. Fewer vessels in a row for brackish water is explained by much higher permeate fluxes in membranes and feed flow rates to each membrane. To keep at bay the in-manifold maldistribution phenomenon (in practice less than 5%), the manifold design with multiple rows should meet the following conditions: rows 0.6 d * D port manifold 1.5, if row 20, Where d port, D manifold - the port and manifold inner diameters, rows total number of rows (on both sides of the pipe manifold if symmetrically located). From equation (1) it follows, that at the total number of rows equal 30 the manifold diameter should be at least 5 times bigger than the port size. (1) If the above hydraulic design criteria (of table 1 and equation 1) are met, the only issue to be tackled with is the pressure loss calculation in a vessel row. Two approaches may be used for pressure loss calculation in a vessel row. One is based on successive step-by-step calculation of all the vessels starting from the vessel farthest from the pipe manifold. It uses the membrane data and the pressure loss curves given in Fig.4 Fig.4 - Pressure loss in the vessel-vessel or manifold-vessel connection This procedure requires special numeric algorithms and a sure choice for software programs. The other approach considers the vessel row as some black box without internal pressure losses. The hydraulic model suggested for quick pressure loss prediction in the U-type rows is shown in Fig.5. In Page 4 of 8
5 this model all pressure losses are applied to only 2 points the feed inlet and the brine outlet. The equivalent hydraulic resistances are depicted below as valves. As known, pressure loss in a valve is described by the flow coefficient Kv (or Cv in the British units). Fig.5 - Hydraulic model for pressure loss prediction in the U-type rows The total pressure loss (in meters of water) is: P loss Feed Kv f 2 Brine Kv b 2,(2) Where P loss total pressure loss in the vessels connections, meters of water, Feed, Brine total flow rates of feed and brine in the row, m 3 /hour; Kv f, Kv b flow coefficients for feed manifold-to-vessel connection and the brine vessel-to-manifold one. The Kv f and Kv b values are read from the graph below (Fig.6) built for ANSI schedule 80 ports). For the 60 and 40 schedules the Kv values are bigger by 5 10%. Page 5 of 8
6 Fig.6 - The Kv value as a function of vessel number in row and the port size. The pressure loss calculation procedure may be summarized as following: 1. Define the feed and brine flow rates and pressures 2. Select the number of vessels in a row 3. Select the port sizes for brine and feed connections from table 1 4. From graph in Fig.6 read the Kv coefficients for feed and brine connections 5. Using equation (1) calculate pressure losses Page 6 of 8
7 Example Let s define the pressure loss for the vessel arrangement shown in Fig.1 containing 2 x 16 rows, three vessels in a row. The feed flow rate to a row is 25 m 3 /h and the brine flow rate is 13.8 m 3 /h. For 2.5 port and 3 vessels in a row the Kv value is Therefore the pressure loss is: P loss m The required manifold minimum inner diameter can be derived from the equation (1). 0.6 inner _ port _ diameter mm D manifold rows * 32 * 315mm As per ANSI B36.10 the nominal pipe size of 14 inch has inner diameter of 319mm. This size is a good choice for the manifold construction. Specifying Multiple-Port vessels Use normal codes to identify the side port vessel, including the diameter, pressure rating and Membrane capacity Ports may be oriented at 0 / 90 / 180 or 270. (in accordance with point 5.5) Ports are available in three diameters, 1½, 2, 2 ½,3 and 4 all with grooved ends for connection to Victaulic or equivalent couplings The diameter required for each port should be notified against the orientation of the port Up to three ports may be specified at each end of a pressure vessel, except when using 2 ½ or higher diameter ports, at which time the number of ports allowed at each end of a vessel is limited to two and only in the configuration of having between them The possible locations of up to 8 ports positions are indicated on the schema on the following page by marking in the right location the code according to the following key: A for 1.5 diameter port B for 2 diameter port C for 2.5 diameter port D for 3 diameter port E for 4 diameter port Page 7 of 8
8 ORDER FORM - 8 SIDE PORT PRESSURE VESSELS Please fill and fax it to your contact at BEL P.O. Number: Customer name: 1.- NEW SYSTEM / EXISTING SYSTEM or replacement. Please provide details: 2. F/C PORTS CONFIGURATION: Please indicate side port requirement on each side of the vessel (Mark the letter indicating port diameter in the box at each required port location) A Ø 1.5 B Ø 2 C Ø 2.5 D Ø 3 E- Ø 4 (Ø 2.5, Ø 3 & Ø 4 ports cannot be mounted in 90 o from each other) 2. NUMBER OF VESSELS: (Please use separate forms for each type in case of multi-type orders) 3. WORKING PRESSURE RATE (PSI): 300 / 450 / 600 / 1,000 / 1,200 / 1, NUMBER OF MEMBRANE ELEMENTS IN EACH VESSEL: (1,,,,,,8) 5. MEMBRANE BRAND AND TYPE: 6. CONFIRM TYPE: BEL8 - S X ) - - M # of ports Ø of port pressure # of membranes (Example: BEL8 - S(4 X 2.5 ) 1,000-7M) 7. PERMEATE PORTS OUTLET: 1.5 NPT male / 1.5 Victaulic grooved / 1 BSP Female 8. ASME code SEC. X, RP stamped vessel: NO / YES (please contact us for pricing) 9. ADAPTERS OPTIONS: two standard adapters / standard & solid (blind) adapter 10. COLOR: STANDARD (white, RAL 9010) / RAL number: (contact for pricing) Customer signature: Date: FOR DETAILS PLEASE VICIT OUR WEBSITE : Page 8 of 8 January 2011
SKID DESIGNS WITH MULTIPORT SYSTEMS PRACTICE CASE
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 SKID DESIGNS WITH MULTIPORT SYSTEMS PRACTICE CASE INTRODUCTION There are well known advantages of the multiport design
More informationEquivalent Length of Fittings
Equivalent Length of Fittings This section provides the equivalent length of piping pressure loss for several ProPEX fittings. The equivalent length is used to approximate the impact the fittings have
More informationTECHNICAL MANUAL 4'' END PORT PRESSURE VESSEL. Lenntech. Tel Fax.
4'' END PORT PRESSURE VESSEL TECHNICAL MANUAL Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 1 Introduction BEL, founded in 1966, specializes in the design and manufacture
More information09 - Choosing /sizing a cylinder and valve
- Choosing /sizing a cylinder and valve - Pipe flow resistence - Valve sizing - Cylinder sizing LII PIPE FLOW RESISTENCE Flow rate Qn Flow rate is calculated as the volume at normal conditions ( atmospheric
More informationModeling a Pressure Safety Valve
Modeling a Pressure Safety Valve Pressure Safety Valves (PSV), Pressure Relief Valves (PRV), and other pressure relieving devices offer protection against overpressure in many types of hydraulic systems.
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory
More informationRestriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate
Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their
More informationicon i150 / i350 Installation / Operation Manual
i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider
More informationThis portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.
Piping Tutorial A piping network represents the flow of fluids through several pieces of equipment. If sufficient variables (flow rate and pressure) are specified on the piping network, CHEMCAD calculates
More informationENGINEERING DRAWING PACKET
Dwg. No. 10100 Rev. G/ ENGINEERING DRAWING PACKET MODEL PRO-8-300-SP 300 PSI SIDE PORT DESIGN PRESSURE at 10ºF 300 PSI MINIMUM OPERATING TEMP.* 0ºF MAXIMUM OPERATING TEMP. 10ºF FACTORY TEST PRESSURE 330
More informationREFERENCE GUIDE. Rev. 0 15/09/2016
VALVE SIZING CALCULATOR REFERENCE GUIDE Rev. 0 15/09/2016 Copyright HIT VALVE S.p.A. 2016 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
More informationSTANDARD FOR CONTROL VALVE SEAT LEAKAGE
11-3 STANDARD FOR CONTROL VALVE SEAT LEAKAGE 1. PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures. 2. SCOPE & LIMITATIONS 2.1 Selection
More informationWaterSense Specification for Spray Sprinkler Bodies. Version 1.0
Version 1.0 September 21, 2017 WaterSense Specification for Spray Sprinkler Bodies 1.0 Scope and Objective This specification establishes the criteria for labeling bodies of spray sprinklers 1 under the
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-PV ASV-PV ASV-PV ASV-BD ASV-M DN 15-40 DN 50 DN 65-100 DN 15-50 DN 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating
More informationSeries 58 SAFETY VALVES 312
312 Series ASME AIR BRASS SAFETY SOLUTION FEATURES AND BENEFITS High quality, corrosion-resistant safety valves Optimum high flow discharge rates CRN OG-3724 S Manufactured under the regulations of the
More informationMODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE
Proceedings of the 37 th International & 4 th National Conference on Fluid Mechanics and Fluid Power FMFP2010 December 16-18, 2010, IIT Madras, Chennai, India FMFP2010 341 MODELING AND SIMULATION OF VALVE
More informationAdvanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati
Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati Module - 4 Hydraulic Jumps Lecture - 1 Rapidly Varied Flow- Introduction Welcome
More informationApplication Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts
Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts Application These application notes allow the variables (nominal valve size, steam flow rate) for self-operated
More information****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH
BC ****** * EX * ****** DWN W.W.POWELL 4-17-75 CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA 4-17-75 AND DISCHARGE HEADERS ASSOCIATED WITH APPR APPR SAFETY RELIEF VALVES SIZE REV APPR A 02.0175.128 L
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationT208VR Series Tank Blanketing Vacuum Regulator
February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease
More informationBladder Tank Installation & System Design Information
Bladder Tank Installation & System Design Information The Chemguard Bladder Tank is one component in a balanced pressure foam proportioning fire protection system. It requires no external power other than
More informationHANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1
HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2
More informationindd indd
122 Safety silencers 3 124-125 introduction 126-127 overview of our products 128-129 dimensioning guidelines 130-131 sizes 1/8 1/2 132-133 sizes 1 2 134-135 special silencers, accessories 136-137 applications
More informationThe Shand & Jurs Model Vapor Guard Tank Blanketing Valve
Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationExperiment 8: Minor Losses
Experiment 8: Minor Losses Purpose: To determine the loss factors for flow through a range of pipe fittings including bends, a contraction, an enlargement and a gate-valve. Introduction: Energy losses
More informationInterface Devices, Inc. Hydraulic Mini Mule
Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER
More informationSTV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.
Applications/ Features: Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems. STV valves provide a high level of balancing accuracy
More informationWatMan WATER RO SYSTEMS FOR DESALINATION
WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general
More informationBall Valves Subsea Series
Ball Valves Subsea Series Internal Pressures to 20,000 psi (1379 bar) Water Depths to 12,500 ft (3810 meters) Autoclave Engineers subsea ball valves have been designed to fulfill the ever growing demand
More informationHYDRAULIC CONTROL VALVES
HYDRAULIC CONTROL VALVES INC. VALVES, INC HYDRAULIC CONTROL VALVES WORKING PRINCIPALS It is automatic hydraulic control valve designed for make desired modulation processes in main valve network line as
More informationSIZING AND CAPACITIES OF GAS PIPING
SIZING AND CAPACITIES OF GAS PIPING A.1 General piping considerations. The first goal of determining the pipe sizing for a fuel gas piping system is to make sure that there is sufficient gas pressure at
More information4" SIDE PORT PRESSURE VESSEL TECHNICAL MANUAL. Lenntech. Tel Fax.
4" SIDE PORT PRESSURE VESSEL TECHNICAL MANUAL Lenntech info@lenntech.com Tel. +31-15-610-900 www.lenntech.com Fax. +31-15-616-89 January 013 Introduction BEL, founded in 1966, specializes in the design
More informationHomework of Chapter (4.2,4.3)
Dead Line: Saturday (24/3/2018) The Islamic University of Gaza, Instructors: Dr. Khalil M. Al Astal Civil Engineering Department, Hydraulics -Discussion, Second semester, 2018. T.A: Eng. Mohammed AbuRahma
More informationMaterials: Rigid PVC body, PVC end plugs, PVC reinforcement cuff, Stainless steel cuff bands
PVC PRESSURE VESSELS AMI.5 DIAMETER, 00 PSI, U-PIN STYLE Attractive.5 PVC pressure vessels available for 14, 1 & 40 length membranes. This style is designed for direct connection to /Applied Membranes
More informationFM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate
December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder
More informationpvc well casing & drop pipe
C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due
More information1 Exam Prep. Tabs and Highlights
1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,
More informationSUMMARY PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS.
Page 1 of 11 SUMMARY There are many problems derived from a reverse flow in a piping system. A solution presented in this paper is the WaStop inline check valve. The paper aims to explain some of the important
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and
More informationConcentration and diafiltration of viral antigens with SmartFlow TFF
The SmartFlow filter Concentration and diafiltration of viral antigens WORKS from NCSRT is intended for concentrating viral antigens from both clarified and non-clarified sources. The subsequent diafiltration
More informationSystem design configurations RO system design LPT 2016
System design configurations RO system design LPT 2016 System design - configuration Topic 1. Standard system configurations Topic 2. Seawater system configurations Topic 4. Something you should know using
More informationGW C300 FLUID CONTROL VALVE PRESSURE REDUCING
Ni Al Bronze PART NUMBER Super Duplex Titanium 3 64.515.14FM 64.515.16FM 64.515.17FM 4 64.516.14FM 64.516.16FM 64.516.17FM 6 64.517.14FM 64.517.16FM 64.517.17FM 8 64.518.14FM 64.518.16FM 64.518.17FM 10
More informationDRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration
DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS Nanofiltration nanofiltration lab experiments Framework This module explains the lab experiment on nanofiltration. Contents This module has the following
More informationInternational Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.
DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008
More informationInstruction Manual No. 742, 8/98
Instruction Manual No. 742, 8/98 Eclipse Ratio Regulators ES Series COPYRIGHT Copyright I997 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationThe Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure
The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure Matthew Gray 1 * and Steve Kestel 1 1 BioChem Technology, King of Prussia, PA *Email: mgray@biochemtech.com ABSTRACT
More informationSINGER MODEL 106/206-RPS-L&H
DESCRIPTION: Model 106/206-RPS-L&H dissipates surges caused by power failure to pumps. The valve anticipates the surge by opening on low line pressure associated with sudden stopping of pumps. This assures
More informationInstruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1
Instruction Manual 742 5/1/2009 Eclipse Ratio Regulators ES Series Version 1 Copyright Copyright 1997 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation
More informationASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer
ASSE International Product (Seal) Listing Program ASSE 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer Manufacturer: Contact Person: E-mail: Address: Laboratory: Laboratory File
More informationThe Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through
More informationG REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES
LAST REVIEW DATE: REVIEW CYCLE: 6/22/11 5 Years SPECIFICATION: TITLE: VOLUME: G-2040-9 REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED 4 and Gas Blue Book REVISIONS: (See
More informationCONTROL VALVE SEAT LEAKAGE
ANSIIFCI 70-2-2006 AMERICAN NATIONAL STANDARD CONTROL VALVE SEAT LEAKAGE \D o N I N I o ~ H U ~ H [/) ~ Fluid Controls Institute, Inc. Spo~sor: Fluid Controls institute, inc. 1300 Sumner Ave Cleveland,
More informationCombination Air Valve Model
Combination Air Valve Model Model C10 /C11 Installation, Operation and Maintenance Manual (IOM) Table of Contents General...Page 2 Safety...Page 2 Operational Data...Page 3 Materials and Connections...Page
More informationLab # 03: Visualization of Shock Waves by using Schlieren Technique
AerE545 Lab # 03: Visualization of Shock Waves by using Schlieren Technique Objectives: 1. To get hands-on experiences about Schlieren technique for flow visualization. 2. To learn how to do the optics
More information1 PIPESYS Application
PIPESYS Application 1-1 1 PIPESYS Application 1.1 Gas Condensate Gathering System In this PIPESYS Application, the performance of a small gascondensate gathering system is modelled. Figure 1.1 shows the
More informationPressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.
Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø
More informationCentriFlow Meter Integrated Air Entrainment System
CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationA REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates
A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 143/AGA REPORT NO 3 - PART2 Paul J LaNasa CPL & Associates PO Box 801304, Houston, TX 77280-1304 ABSTRACT Periodically, natural gas measurement standards
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationNorth American 7339 High Pressure Gas Regulators
Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationProcess Dynamics, Operations, and Control Lecture Notes - 20
Lesson 0. Control valves 0.0 Context Controller output is a signal that varies between 0 and 100%. Putting this signal to use requires a final control element, a device that responds to the controller
More informationFILTER TYPE PRESSURE SNUBBER
FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure
More informationBERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.
Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationF l o w c o n T R o l v a l v E S
Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,
More informationGAS SUPPLY APPLICATION GUIDE
GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers
More informationI.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES
BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES M. R. Marshall* and P. L. Stewart-Darling* A simple mathematical model for the buoyancy driven ventilation of an enclosed space, using a two-pipe
More informationNORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21
NORDCALC User Guide Table of Contents NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab... 5 Calculating the gas flow rate for gaseous medium... 6 Calculating the pressure drop for gaseous
More informationIndustrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR
More informationS300 Series. Valve Link. Features. Fisher Controls
S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a
More informationMZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION
01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The
More informationMembrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.
Membrane modules for nitrogen and oxygen generator systems Technology Overview ENGINEERING YOUR SUCCESS. Parker modules the heart of OEM tailor-made nitrogen generators OEM (Original Equipment Manufacturer)
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationdirectional control valve series cv691
directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages
More informationCSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING
CSC-2000 SERIES Reset Volume Controllers MADE IN U.S.A. DESCRIPTION The CSC-2000 series are designed for use on VAV terminal units in HVAC systems. These are submaster air velocity controllers whose velocity
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationHANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1
HANDBOOK Ed. 2017 1 CHAPTER 5 SELECTION CRITERIA FOR SAFETY VALVES CALCULATION OF THE DISCHARGE CAPACITY (Ref. EN 13136:2013) The evaluation of the minimum required discharge capacity of safety valves
More informationAutomatic balancing valves
Automatic balancing valves ASV DN 15-50 (4th gen.) ASV-PV ASV-BD ASV-M DN 15-50 DN 15-50 DN 15-50 Description ASV whiteboard animation ASV valves are automatic balancing valves. Together with Danfoss presetting
More informationSmart Water Application Technologies (SWAT) TM
Smart Water Application Technologies (SWAT) TM Equipment Functionality Test Protocol Version 2.3 June 2014 SWAT Committee 8280 Willow Oaks Corporate Drive Suite 400 Fairfax, VA 22031 www.irrigation.org
More informationENERGY BLADE 3K4. Energy Blade Installation Instructions
ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and
More informationProcess Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration
Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration inshare By Steve Kestel and Tilo Stahl (BioChem Technology) and Matthew Gray (Keystone Engineering Group) Introduction
More informationSOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS
1 SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS DESCRIPTION OF A PULSATION DAMPENER AND HOW IT WORKS A pulsation dampener is a vessel
More informationPilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw.
GAS PRESSURE REDUCING BALANCED APPLICATIONS: Regulation of inlet pressure to gas compressors and control of supply or distribution system pressures where the pressure to the regulator varies significantly
More informationThe Discussion of this exercise covers the following points:
Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop
More informationPTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationSmart Water Application Technologies (SWAT)
Smart Water Application Technologies (SWAT) Turf and Landscape Irrigation Equipment PRESSURE REGULATING SPRAY HEAD SPRINKLERS Equipment Functionality Test Testing Protocol Version 3.0 (May 2012) Developed
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationIntroduction. Part one: Identify the Hydraulic Trainer Components
The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More information