1 INTRODUCTION Multiple port vessels. Hydraulic design of side-ported RO vessel arrangements (How to get the best out of the side-ported vessels) This document has the final target to show the best multiport hydraulic arrangement in skids. However, the reader has to bear in mind that the following document it is only a recommendation and every case must be studied in depth in order to reach the best configuration, and we cannot avoid the economical point of the issue. In every installation, we should bear in mind both terms Technical VS Economical in order to reach a point of optimization which let us be competitive in our bids. The reader must consider this document as an initial guideline to get the best technical solution, but normally the best technical solution implies a higher cost. Based on the experience of many years in this kind of applications, from our technical department BEL can offer our clients our support and our fully disposition to study the best configuration, considering the economical & technical terms, in order to give you the most attractive solution for your end users. HYDRAULIC DESIGN OF SIDE-PORTED RO VESSEL ARRANGEMENTS Generally any RO vessels arrangement has two primary elements: the vessel row and the pipe manifolds (Fig.1) Fig. 1 - Basic side-ported RO vessels arrangement elements Page 1 of 8

2 From hydraulics point of view the side-ported vessels and pipe manifolds may be connected in a number of ways (Fig.2) Fig.2 - Hydraulic classification of the side-ported vessels and pipe manifolds connections (in clockwise direction): 1. S-type row; 2. U-type row; 3. S-type manifold; 4. U-type manifold; In the S-type row of vessels the feed inlet and brine outlet for the row are in the opposite vessels. For U-type row the feed inlet and the brine outlet are in the same vessel. The former type is rarely used. The S-type and U-type manifold arrangements consider the feed and brine streams distribution to the vessel rows and collection from the rows. In the S-type manifold connection to the vessel rows the feed and brine streams in the dividing and collecting manifolds are in the same direction. In the U-type manifold connection the afore-mentioned streams are in opposite directions (Fig.2). In designing the vessel arrangement three hydraulic phenomena shall be taken into account: 1. Pressure losses in connections of vessels and manifolds, 2. The feed flow maldistribution between the vessels in the same row, 3. The feed flow maldistribution between the vessel rows connected to the same dividing and collecting manifolds. The pressure losses in the feed and brine streams have direct effect on the process energy consumption and productivity. They can t be neglected even at the preliminary design stage of the RO desalination unit as the loss in production may be surprisingly high up to 3 8%. The flow maldistribution may be measured by the ratio of minimum flow rate of the feed trough the vessel to the feed flow maximum value. For example, in the U-type row the first vessel accepts the maximum fed flow, while the vessel farthest from the manifold receives the minimum flow. In the U-type manifold the picture is quite the opposite: the row nearest to the inlet receives the minimum feed flow rate. This behavior is inherent and has a theory-grounded explanation. In a dividing manifold, the flow diverted to the vessel causes the main stream to decelerate and its static pressure to increase stepwise. Thus, the pressure drop across the vessel row increases progressively with its distance from the inlet. This results in hydraulic non-uniformity with the maximum flow in the row farthest from the manifold inlet. In a combining manifold, the velocity in the main stream increases as the branch streams from the vessel rows progressively merge into it. It causes the static pressure in the manifold to drop downstream, its minimum being at the manifold outlet. Minimum and maximum Page 2 of 8

3 pressure areas in both manifolds define extreme flows through the vessels. Generally the S-type manifolds perform better than the U-type ones. The feed flow maldistribution results in the recovery maldistribution working in the opposite direction; the higher the flow rate the lower the recovery. Fig. 3 gives fair indication of the predicted maldistribution effect in a row containing 6 vessels. Two cases are compared the 2-inch and 3-inch side ports for feed and brine. Fig.3 - The vessel feed flow rate and membrane recovery maldistribution in the U-type row for seawater of 62 Bar, at the maximum permeate flux of 27 l/(m2*h), recovery of 45%, and fouling of 80%. In hydraulically faulty designs the flow maldistribution may reach 15% (abs), the maximum recovery maldistribution being below 5%. It leads to a less effective usage of the RO membranes and shortens their life. To limit the extents of the in-row maldistribution phenomenon the maximum number of vessels in a row shall be limited to the figures given in Table 1 Table 1 - Maximum number of vessels in a single row* port size Sea Water Brackish Water NOTE*- These table shows theoretical values, but every single case should be study, mainly because the sizing of ports will depend on the flows of the systems. Page 3 of 8

4 For brackish water desalination at the recovery above 65% the brine discharge connection size may be reduced as compared to the feed connection size. Fewer vessels in a row for brackish water is explained by much higher permeate fluxes in membranes and feed flow rates to each membrane. To keep at bay the in-manifold maldistribution phenomenon (in practice less than 5%), the manifold design with multiple rows should meet the following conditions: rows 0.6 d * D port manifold 1.5, if row 20, Where d port, D manifold - the port and manifold inner diameters, rows total number of rows (on both sides of the pipe manifold if symmetrically located). From equation (1) it follows, that at the total number of rows equal 30 the manifold diameter should be at least 5 times bigger than the port size. (1) If the above hydraulic design criteria (of table 1 and equation 1) are met, the only issue to be tackled with is the pressure loss calculation in a vessel row. Two approaches may be used for pressure loss calculation in a vessel row. One is based on successive step-by-step calculation of all the vessels starting from the vessel farthest from the pipe manifold. It uses the membrane data and the pressure loss curves given in Fig.4 Fig.4 - Pressure loss in the vessel-vessel or manifold-vessel connection This procedure requires special numeric algorithms and a sure choice for software programs. The other approach considers the vessel row as some black box without internal pressure losses. The hydraulic model suggested for quick pressure loss prediction in the U-type rows is shown in Fig.5. In Page 4 of 8

5 this model all pressure losses are applied to only 2 points the feed inlet and the brine outlet. The equivalent hydraulic resistances are depicted below as valves. As known, pressure loss in a valve is described by the flow coefficient Kv (or Cv in the British units). Fig.5 - Hydraulic model for pressure loss prediction in the U-type rows The total pressure loss (in meters of water) is: P loss Feed Kv f 2 Brine Kv b 2,(2) Where P loss total pressure loss in the vessels connections, meters of water, Feed, Brine total flow rates of feed and brine in the row, m 3 /hour; Kv f, Kv b flow coefficients for feed manifold-to-vessel connection and the brine vessel-to-manifold one. The Kv f and Kv b values are read from the graph below (Fig.6) built for ANSI schedule 80 ports). For the 60 and 40 schedules the Kv values are bigger by 5 10%. Page 5 of 8

6 Fig.6 - The Kv value as a function of vessel number in row and the port size. The pressure loss calculation procedure may be summarized as following: 1. Define the feed and brine flow rates and pressures 2. Select the number of vessels in a row 3. Select the port sizes for brine and feed connections from table 1 4. From graph in Fig.6 read the Kv coefficients for feed and brine connections 5. Using equation (1) calculate pressure losses Page 6 of 8

7 Example Let s define the pressure loss for the vessel arrangement shown in Fig.1 containing 2 x 16 rows, three vessels in a row. The feed flow rate to a row is 25 m 3 /h and the brine flow rate is 13.8 m 3 /h. For 2.5 port and 3 vessels in a row the Kv value is Therefore the pressure loss is: P loss m The required manifold minimum inner diameter can be derived from the equation (1). 0.6 inner _ port _ diameter mm D manifold rows * 32 * 315mm As per ANSI B36.10 the nominal pipe size of 14 inch has inner diameter of 319mm. This size is a good choice for the manifold construction. Specifying Multiple-Port vessels Use normal codes to identify the side port vessel, including the diameter, pressure rating and Membrane capacity Ports may be oriented at 0 / 90 / 180 or 270. (in accordance with point 5.5) Ports are available in three diameters, 1½, 2, 2 ½,3 and 4 all with grooved ends for connection to Victaulic or equivalent couplings The diameter required for each port should be notified against the orientation of the port Up to three ports may be specified at each end of a pressure vessel, except when using 2 ½ or higher diameter ports, at which time the number of ports allowed at each end of a vessel is limited to two and only in the configuration of having between them The possible locations of up to 8 ports positions are indicated on the schema on the following page by marking in the right location the code according to the following key: A for 1.5 diameter port B for 2 diameter port C for 2.5 diameter port D for 3 diameter port E for 4 diameter port Page 7 of 8

8 ORDER FORM - 8 SIDE PORT PRESSURE VESSELS Please fill and fax it to your contact at BEL P.O. Number: Customer name: 1.- NEW SYSTEM / EXISTING SYSTEM or replacement. Please provide details: 2. F/C PORTS CONFIGURATION: Please indicate side port requirement on each side of the vessel (Mark the letter indicating port diameter in the box at each required port location) A Ø 1.5 B Ø 2 C Ø 2.5 D Ø 3 E- Ø 4 (Ø 2.5, Ø 3 & Ø 4 ports cannot be mounted in 90 o from each other) 2. NUMBER OF VESSELS: (Please use separate forms for each type in case of multi-type orders) 3. WORKING PRESSURE RATE (PSI): 300 / 450 / 600 / 1,000 / 1,200 / 1, NUMBER OF MEMBRANE ELEMENTS IN EACH VESSEL: (1,,,,,,8) 5. MEMBRANE BRAND AND TYPE: 6. CONFIRM TYPE: BEL8 - S X ) - - M # of ports Ø of port pressure # of membranes (Example: BEL8 - S(4 X 2.5 ) 1,000-7M) 7. PERMEATE PORTS OUTLET: 1.5 NPT male / 1.5 Victaulic grooved / 1 BSP Female 8. ASME code SEC. X, RP stamped vessel: NO / YES (please contact us for pricing) 9. ADAPTERS OPTIONS: two standard adapters / standard & solid (blind) adapter 10. COLOR: STANDARD (white, RAL 9010) / RAL number: (contact for pricing) Customer signature: Date: FOR DETAILS PLEASE VICIT OUR WEBSITE : Page 8 of 8 January 2011

SKID DESIGNS WITH MULTIPORT SYSTEMS PRACTICE CASE

SKID DESIGNS WITH MULTIPORT SYSTEMS PRACTICE CASE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 SKID DESIGNS WITH MULTIPORT SYSTEMS PRACTICE CASE INTRODUCTION There are well known advantages of the multiport design

More information

Equivalent Length of Fittings

Equivalent Length of Fittings Equivalent Length of Fittings This section provides the equivalent length of piping pressure loss for several ProPEX fittings. The equivalent length is used to approximate the impact the fittings have

More information

TECHNICAL MANUAL 4'' END PORT PRESSURE VESSEL. Lenntech. Tel Fax.

TECHNICAL MANUAL 4'' END PORT PRESSURE VESSEL. Lenntech. Tel Fax. 4'' END PORT PRESSURE VESSEL TECHNICAL MANUAL Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 1 Introduction BEL, founded in 1966, specializes in the design and manufacture

More information

09 - Choosing /sizing a cylinder and valve

09 - Choosing /sizing a cylinder and valve - Choosing /sizing a cylinder and valve - Pipe flow resistence - Valve sizing - Cylinder sizing LII PIPE FLOW RESISTENCE Flow rate Qn Flow rate is calculated as the volume at normal conditions ( atmospheric

More information

Modeling a Pressure Safety Valve

Modeling a Pressure Safety Valve Modeling a Pressure Safety Valve Pressure Safety Valves (PSV), Pressure Relief Valves (PRV), and other pressure relieving devices offer protection against overpressure in many types of hydraulic systems.

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory

More information

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their

More information

icon i150 / i350 Installation / Operation Manual

icon i150 / i350 Installation / Operation Manual i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider

More information

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes. Piping Tutorial A piping network represents the flow of fluids through several pieces of equipment. If sufficient variables (flow rate and pressure) are specified on the piping network, CHEMCAD calculates

More information

ENGINEERING DRAWING PACKET

ENGINEERING DRAWING PACKET Dwg. No. 10100 Rev. G/ ENGINEERING DRAWING PACKET MODEL PRO-8-300-SP 300 PSI SIDE PORT DESIGN PRESSURE at 10ºF 300 PSI MINIMUM OPERATING TEMP.* 0ºF MAXIMUM OPERATING TEMP. 10ºF FACTORY TEST PRESSURE 330

More information

REFERENCE GUIDE. Rev. 0 15/09/2016

REFERENCE GUIDE. Rev. 0 15/09/2016 VALVE SIZING CALCULATOR REFERENCE GUIDE Rev. 0 15/09/2016 Copyright HIT VALVE S.p.A. 2016 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

STANDARD FOR CONTROL VALVE SEAT LEAKAGE 11-3 STANDARD FOR CONTROL VALVE SEAT LEAKAGE 1. PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures. 2. SCOPE & LIMITATIONS 2.1 Selection

More information

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0 Version 1.0 September 21, 2017 WaterSense Specification for Spray Sprinkler Bodies 1.0 Scope and Objective This specification establishes the criteria for labeling bodies of spray sprinklers 1 under the

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-PV ASV-PV ASV-PV ASV-BD ASV-M DN 15-40 DN 50 DN 65-100 DN 15-50 DN 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating

More information

Series 58 SAFETY VALVES 312

Series 58 SAFETY VALVES 312 312 Series ASME AIR BRASS SAFETY SOLUTION FEATURES AND BENEFITS High quality, corrosion-resistant safety valves Optimum high flow discharge rates CRN OG-3724 S Manufactured under the regulations of the

More information

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE Proceedings of the 37 th International & 4 th National Conference on Fluid Mechanics and Fluid Power FMFP2010 December 16-18, 2010, IIT Madras, Chennai, India FMFP2010 341 MODELING AND SIMULATION OF VALVE

More information

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati Module - 4 Hydraulic Jumps Lecture - 1 Rapidly Varied Flow- Introduction Welcome

More information

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts Application These application notes allow the variables (nominal valve size, steam flow rate) for self-operated

More information

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH BC ****** * EX * ****** DWN W.W.POWELL 4-17-75 CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA 4-17-75 AND DISCHARGE HEADERS ASSOCIATED WITH APPR APPR SAFETY RELIEF VALVES SIZE REV APPR A 02.0175.128 L

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Bladder Tank Installation & System Design Information

Bladder Tank Installation & System Design Information Bladder Tank Installation & System Design Information The Chemguard Bladder Tank is one component in a balanced pressure foam proportioning fire protection system. It requires no external power other than

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

indd indd

indd indd 122 Safety silencers 3 124-125 introduction 126-127 overview of our products 128-129 dimensioning guidelines 130-131 sizes 1/8 1/2 132-133 sizes 1 2 134-135 special silencers, accessories 136-137 applications

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Experiment 8: Minor Losses

Experiment 8: Minor Losses Experiment 8: Minor Losses Purpose: To determine the loss factors for flow through a range of pipe fittings including bends, a contraction, an enlargement and a gate-valve. Introduction: Energy losses

More information

Interface Devices, Inc. Hydraulic Mini Mule

Interface Devices, Inc. Hydraulic Mini Mule Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER

More information

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems. Applications/ Features: Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems. STV valves provide a high level of balancing accuracy

More information

WatMan WATER RO SYSTEMS FOR DESALINATION

WatMan WATER RO SYSTEMS FOR DESALINATION WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general

More information

Ball Valves Subsea Series

Ball Valves Subsea Series Ball Valves Subsea Series Internal Pressures to 20,000 psi (1379 bar) Water Depths to 12,500 ft (3810 meters) Autoclave Engineers subsea ball valves have been designed to fulfill the ever growing demand

More information

HYDRAULIC CONTROL VALVES

HYDRAULIC CONTROL VALVES HYDRAULIC CONTROL VALVES INC. VALVES, INC HYDRAULIC CONTROL VALVES WORKING PRINCIPALS It is automatic hydraulic control valve designed for make desired modulation processes in main valve network line as

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING SIZING AND CAPACITIES OF GAS PIPING A.1 General piping considerations. The first goal of determining the pipe sizing for a fuel gas piping system is to make sure that there is sufficient gas pressure at

More information

4" SIDE PORT PRESSURE VESSEL TECHNICAL MANUAL. Lenntech. Tel Fax.

4 SIDE PORT PRESSURE VESSEL TECHNICAL MANUAL. Lenntech. Tel Fax. 4" SIDE PORT PRESSURE VESSEL TECHNICAL MANUAL Lenntech info@lenntech.com Tel. +31-15-610-900 www.lenntech.com Fax. +31-15-616-89 January 013 Introduction BEL, founded in 1966, specializes in the design

More information

Homework of Chapter (4.2,4.3)

Homework of Chapter (4.2,4.3) Dead Line: Saturday (24/3/2018) The Islamic University of Gaza, Instructors: Dr. Khalil M. Al Astal Civil Engineering Department, Hydraulics -Discussion, Second semester, 2018. T.A: Eng. Mohammed AbuRahma

More information

Materials: Rigid PVC body, PVC end plugs, PVC reinforcement cuff, Stainless steel cuff bands

Materials: Rigid PVC body, PVC end plugs, PVC reinforcement cuff, Stainless steel cuff bands PVC PRESSURE VESSELS AMI.5 DIAMETER, 00 PSI, U-PIN STYLE Attractive.5 PVC pressure vessels available for 14, 1 & 40 length membranes. This style is designed for direct connection to /Applied Membranes

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

pvc well casing & drop pipe

pvc well casing & drop pipe C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due

More information

1 Exam Prep. Tabs and Highlights

1 Exam Prep. Tabs and Highlights 1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,

More information

SUMMARY PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS.

SUMMARY PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS. Page 1 of 11 SUMMARY There are many problems derived from a reverse flow in a piping system. A solution presented in this paper is the WaStop inline check valve. The paper aims to explain some of the important

More information

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and

More information

Concentration and diafiltration of viral antigens with SmartFlow TFF

Concentration and diafiltration of viral antigens with SmartFlow TFF The SmartFlow filter Concentration and diafiltration of viral antigens WORKS from NCSRT is intended for concentrating viral antigens from both clarified and non-clarified sources. The subsequent diafiltration

More information

System design configurations RO system design LPT 2016

System design configurations RO system design LPT 2016 System design configurations RO system design LPT 2016 System design - configuration Topic 1. Standard system configurations Topic 2. Seawater system configurations Topic 4. Something you should know using

More information

GW C300 FLUID CONTROL VALVE PRESSURE REDUCING

GW C300 FLUID CONTROL VALVE PRESSURE REDUCING Ni Al Bronze PART NUMBER Super Duplex Titanium 3 64.515.14FM 64.515.16FM 64.515.17FM 4 64.516.14FM 64.516.16FM 64.516.17FM 6 64.517.14FM 64.517.16FM 64.517.17FM 8 64.518.14FM 64.518.16FM 64.518.17FM 10

More information

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS Nanofiltration nanofiltration lab experiments Framework This module explains the lab experiment on nanofiltration. Contents This module has the following

More information

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

International Journal of Technical Research and Applications e-issn: ,  Volume 4, Issue 3 (May-June, 2016), PP. DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008

More information

Instruction Manual No. 742, 8/98

Instruction Manual No. 742, 8/98 Instruction Manual No. 742, 8/98 Eclipse Ratio Regulators ES Series COPYRIGHT Copyright I997 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure Matthew Gray 1 * and Steve Kestel 1 1 BioChem Technology, King of Prussia, PA *Email: mgray@biochemtech.com ABSTRACT

More information

SINGER MODEL 106/206-RPS-L&H

SINGER MODEL 106/206-RPS-L&H DESCRIPTION: Model 106/206-RPS-L&H dissipates surges caused by power failure to pumps. The valve anticipates the surge by opening on low line pressure associated with sudden stopping of pumps. This assures

More information

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1 Instruction Manual 742 5/1/2009 Eclipse Ratio Regulators ES Series Version 1 Copyright Copyright 1997 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer ASSE International Product (Seal) Listing Program ASSE 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer Manufacturer: Contact Person: E-mail: Address: Laboratory: Laboratory File

More information

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through

More information

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES LAST REVIEW DATE: REVIEW CYCLE: 6/22/11 5 Years SPECIFICATION: TITLE: VOLUME: G-2040-9 REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED 4 and Gas Blue Book REVISIONS: (See

More information

CONTROL VALVE SEAT LEAKAGE

CONTROL VALVE SEAT LEAKAGE ANSIIFCI 70-2-2006 AMERICAN NATIONAL STANDARD CONTROL VALVE SEAT LEAKAGE \D o N I N I o ~ H U ~ H [/) ~ Fluid Controls Institute, Inc. Spo~sor: Fluid Controls institute, inc. 1300 Sumner Ave Cleveland,

More information

Combination Air Valve Model

Combination Air Valve Model Combination Air Valve Model Model C10 /C11 Installation, Operation and Maintenance Manual (IOM) Table of Contents General...Page 2 Safety...Page 2 Operational Data...Page 3 Materials and Connections...Page

More information

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Lab # 03: Visualization of Shock Waves by using Schlieren Technique AerE545 Lab # 03: Visualization of Shock Waves by using Schlieren Technique Objectives: 1. To get hands-on experiences about Schlieren technique for flow visualization. 2. To learn how to do the optics

More information

1 PIPESYS Application

1 PIPESYS Application PIPESYS Application 1-1 1 PIPESYS Application 1.1 Gas Condensate Gathering System In this PIPESYS Application, the performance of a small gascondensate gathering system is modelled. Figure 1.1 shows the

More information

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5. Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø

More information

CentriFlow Meter Integrated Air Entrainment System

CentriFlow Meter Integrated Air Entrainment System CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 143/AGA REPORT NO 3 - PART2 Paul J LaNasa CPL & Associates PO Box 801304, Houston, TX 77280-1304 ABSTRACT Periodically, natural gas measurement standards

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

North American 7339 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Process Dynamics, Operations, and Control Lecture Notes - 20

Process Dynamics, Operations, and Control Lecture Notes - 20 Lesson 0. Control valves 0.0 Context Controller output is a signal that varies between 0 and 100%. Putting this signal to use requires a final control element, a device that responds to the controller

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve. Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

F l o w c o n T R o l v a l v E S

F l o w c o n T R o l v a l v E S Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,

More information

GAS SUPPLY APPLICATION GUIDE

GAS SUPPLY APPLICATION GUIDE GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers

More information

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES M. R. Marshall* and P. L. Stewart-Darling* A simple mathematical model for the buoyancy driven ventilation of an enclosed space, using a two-pipe

More information

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21

NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab Torque Calculation & Actuator Mounting Data tab... 21 NORDCALC User Guide Table of Contents NORDCALC Introduction... 2 Registration... 2 Flow Calculations tab... 5 Calculating the gas flow rate for gaseous medium... 6 Calculating the pressure drop for gaseous

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION 01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The

More information

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS. Membrane modules for nitrogen and oxygen generator systems Technology Overview ENGINEERING YOUR SUCCESS. Parker modules the heart of OEM tailor-made nitrogen generators OEM (Original Equipment Manufacturer)

More information

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING CSC-2000 SERIES Reset Volume Controllers MADE IN U.S.A. DESCRIPTION The CSC-2000 series are designed for use on VAV terminal units in HVAC systems. These are submaster air velocity controllers whose velocity

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 1 CHAPTER 5 SELECTION CRITERIA FOR SAFETY VALVES CALCULATION OF THE DISCHARGE CAPACITY (Ref. EN 13136:2013) The evaluation of the minimum required discharge capacity of safety valves

More information

Automatic balancing valves

Automatic balancing valves Automatic balancing valves ASV DN 15-50 (4th gen.) ASV-PV ASV-BD ASV-M DN 15-50 DN 15-50 DN 15-50 Description ASV whiteboard animation ASV valves are automatic balancing valves. Together with Danfoss presetting

More information

Smart Water Application Technologies (SWAT) TM

Smart Water Application Technologies (SWAT) TM Smart Water Application Technologies (SWAT) TM Equipment Functionality Test Protocol Version 2.3 June 2014 SWAT Committee 8280 Willow Oaks Corporate Drive Suite 400 Fairfax, VA 22031 www.irrigation.org

More information

ENERGY BLADE 3K4. Energy Blade Installation Instructions

ENERGY BLADE 3K4. Energy Blade Installation Instructions ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and

More information

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration inshare By Steve Kestel and Tilo Stahl (BioChem Technology) and Matthew Gray (Keystone Engineering Group) Introduction

More information

SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS

SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS 1 SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS DESCRIPTION OF A PULSATION DAMPENER AND HOW IT WORKS A pulsation dampener is a vessel

More information

Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw.

Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw. GAS PRESSURE REDUCING BALANCED APPLICATIONS: Regulation of inlet pressure to gas compressors and control of supply or distribution system pressures where the pressure to the regulator varies significantly

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

Smart Water Application Technologies (SWAT)

Smart Water Application Technologies (SWAT) Smart Water Application Technologies (SWAT) Turf and Landscape Irrigation Equipment PRESSURE REGULATING SPRAY HEAD SPRINKLERS Equipment Functionality Test Testing Protocol Version 3.0 (May 2012) Developed

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

Introduction. Part one: Identify the Hydraulic Trainer Components

Introduction. Part one: Identify the Hydraulic Trainer Components The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify

More information

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information