THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES

Size: px
Start display at page:

Download "THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES"

Transcription

1 THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES A Report for National Measurement System Department for Innovation, Universities and Skills Kingsgate House Victoria Street London SWE 6SW Project No: FFRE45 April 2008 Report No: XXXX/XXX MONTH YEAR Project No: XXXXXX Page of XX

2 The work described in this report was carried out by TUV NEL Ltd under contract to the Department for Innovation, Universities & Skills ( the Department ) as part of the National Measurement System s Engineering & Flow Programme. The Department has a free licence to copy, circulate and use the contents of this report within any United Kingdom Government Department, and to issue or copy the contents of the report to a supplier or potential supplier to the United Kingdom Government for a contract for the services of the Crown. For all other use, the prior written consent of TUV NEL Ltd shall be obtained before reproducing all or any part of this report. Applications for permission to publish should be made to: Contracts Manager TUV NEL Ltd Scottish Enterprise Technology Park East Kilbride G75 0QF jduff@tuvnel.com Tel: +44 (0) TUV NEL Ltd 2007

3 TUV NEL Ltd EAST KILBRIDE GLASGOW G75 0QF UK Tel: +44 (0) Fax: +44 (0) THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES A Report for National Measurement System Department for Innovation, Universities and Skills Kingsgate House Victoria Street London SWE 6SW Prepared by: Date: 2 st April 2008 Dr D Hodges Approved by: Date: 2 st April 2008 Dr M J Reader-Harris for M Valente Managing Director Project No: FFRE45 Page of 39 April 2008

4 SUMMARY Two 8-inch orifice plates of diameter ratio 0.4 and 0.6 (with the diameter ratio 0.4 plate modified to a value of 0.42 after initial testing) have been tested in the TUV NEL wet-gas test facility. The aim of the tests was to investigate the over-reading performance of the plates and to determine if the presence of a drain hole influenced the plate performance, in both dry and wet-gas operating conditions. Operating pressures of 20 and 60 bar gauge were used for the test programme, with gas flow rates over the range 00 to 200 Am 3 /hr and a Lockhart-Martinelli parameter range of 0 to 0.3. Dry-gas baseline tests were completed prior to performing the wet-gas tests to determine the discharge-coefficient performance of the plates. The diameter ratio 0.6 plate gave a discharge coefficient within the uncertainty band defined by ISO 567-2:2003; however, the results for the diameter ratio 0.4 plate were found to be outside its corresponding uncertainty band. To improve the performance of this plate it was re-machined to produce a larger diameter ratio of 0.42 with a sharper leading edge. When the plate was retested the discharge coefficient was found to have shifted to the expected range of values, indicating that the re-machining had been successful. The performance of the orifice plates in wet gas was found to be somewhat inconsistent. The diameter ratio 0.6 plate produced wet-gas over-readings that were all very similar, irrespective of the gas flow rate. This is consistent with the fact that below a gas densiometric Froude number of.5, the two-phase flow pattern in the pipe tends to be of the stratified type, with only a small amount of liquid entrained in the gas phase. As the flow pattern is fairly constant it is expected that the over-reading will also not change much. However, the wet-gas over-readings for the diameter ratio 0.4 (and 0.42) plate showed a large spread as a function of the gas flow rate/froude number. This is inconsistent with the results for the diameter ratio 0.6 plate. The reason or reasons for the differences in the orifice-plate performance is currently unresolved. The drain hole used on the diameter ratio 0.6 orifice plate was found to shift the dry-gas discharge coefficient by 2.4% and.4% for the two pairs of flange tappings used, which is consistent with test work conducted on 4-inch orifice plates with drain holes []. As indicated by the differences in the shifts, the discharge coefficient is sensitive to the relative location of the tappings and the drain hole. The presence of the drain hole was found to have only a small effect on the over-reading performance of the plate. Project No: FFRE45 Page 2 of 39 April 2008

5 C O N T E N T S Page INTRODUCTION THE TUV NEL WET-GAS TEST FACILITY ORIFICE PLATE INSTALLATION AND TEST CONDITIONS RESULTS AND DISCUSSION DRY-GAS BASELINE RESULTS WET-GAS RESULTS DENSITY RATIO, DIAMETER-RATIO AND DRAIN HOLE EFFECTS THE EFFECT OF THE DRAIN HOLE CONCLUSIONS REFERENCES Project No: FFRE45 Page 3 of 39 April 2008

6 NOTATION A D Upstream Pipe Area m 2 A d Orifice Bore Area m 2 C Chisholm Model Constant - C gas Discharge - D Upstream Pipe Diameter m d Orifice Plate Bore m E Velocity of Approach Factor - Fr gas Gas Densiometric Froude number - g Acceleration due to Gravity m/s 2 Flow - m gas Gas Mass Flowrate kg/s m liquid Liquid Mass Flowrate kg/s Re Pipe Reynolds Number - X Lockhart-Martinelli Parameter - β Orifice Plate Diameter ratio (= d/d) - p gas Differential Pressure if only Dry Gas is/were flowing Pa p wet-gas Differential Pressure in Wet Gas Pa ε gas Gas Expansibility Factor - ρ gas Gas Density kg/m 3 ρ liquid Liquid Density kg/m 3 φ Orifice Plate Wet-Gas Over-Reading - Project No: FFRE45 Page 4 of 39 April 2008

7 INTRODUCTION Despite recent advances in other flow metering technologies, the simplicity, reliability and capital cost of the orifice plate have ensured that it remains the instrument of choice for many applications. It is by far the most common flow meter in industrial service, accounting for over 40 per cent of the market, across a wide range of sectors including oil and gas, process, energy and chemical. However, where an orifice plate is used to meter a gas flow, the presence of small quantities of entrained liquid can present a problem as, if steps are not taken to allow the liquid to pass the plate, a pool will build up against the upstream face and undermine the metering accuracy. The most widely applied solution is to provide a liquid bypass in the form of a drain hole in the plate allowing liquids in a gas stream to pass through the plate. While drain-hole plates are a cost-effective way of measuring gas with a low liquid content, they are not as accurate as the standard design. As the extent of this inaccuracy is not well documented and as industry is sceptical of the existing formula, drain-hole plates are not as widely used as they might be: new data are therefore needed to give confidence in their use. Applications for the work include: gas off-take measurement where hydrocarbon liquids can be entrained, causing errors in inter-field allocation and impacting on company and tax revenues; gas-metering systems where water from compressor cleaning has to pass through the meter; and steam metering where condensate is present. Single-phase tests are described in []; wet-gas tests are described here. 2 THE TUV NEL WET-GAS TEST FACILITY The high-pressure wet-gas test facility at TUV NEL is based around a 6-inch (nominal bore) re-circulating loop and a 2 m 3 gas/liquid separator. A schematic diagram of the test facility arrangement is provided in Fig. (note, however, that only one test line is shown in this sketch). Although nominally 6-inch diameter, the two parallel test sections available can accommodate line sizes ranging from 4 inch to 8 inch. The natural gas/condensate simulant fluids used are oxygen-free nitrogen and a kerosene substitute (trade name Exxsol D80). At 20 o C the liquid phase has a density of kg/m 3 and a viscosity of cp. The facility operates at a nominal temperature of 8 C over a nominal pressure range of 5 to 63 bar gauge. This pressure range corresponds to a gas density range of 8.6 to 74.5 kg/m 3. Referring to the schematic diagram in Fig., gas is drawn from the top of the separator and is driven around the test loop by a 200 kw blower. The maximum achievable pressure-independent dry gas volumetric flow rate is 500 m 3 /hr when operating in wet gas mode (i.e. flowing through the separator), and at the minimum 6-inch test line resistance (i.e. no test meter installed). Liquid is injected using a 30 kw, -stage centrifugal pump through a specially designed spool over 60D upstream of the test section, up to a maximum flow rate of 80 m 3 /hr (minimum flow rate is 0.2 m 3 /hr). The gas and liquid phases mix at the injection point and pass through the test section in a form dictated by the gas velocity and pressure. The two-phase mixture then passes back into the separator for separation and recirculation. The gas and liquid stream temperatures are both maintained at a set level (to within ± 0. o C) using two chilled-water-controlled shell-and-tube heat exchangers. Project No: FFRE45 Page 5 of 39 April 2008

8 The gas flow rate is controlled by varying the speed of the blower, while the liquid injection flow rates are set manually at the injection point. The gas reference volumetric flow rate is measured using a 6-inch Daniel SeniorSonic ultrasonic meter, while the liquid reference flow rates are measured using traceable calibrated turbine meters. For the test work described in this report the expanded uncertainty on the gas reference volumetric flow rate is 0.5% and on the liquid reference volumetric flow rates measured is 0.2% (all at the 95% confidence level). All temperature, pressure and differential-pressure measurements are taken using traceable calibrated instrumentation. A modified sub-sea video camera can be used to monitor the two-phase flow in the test section. The camera allows the transition from stratified flow to annular-mist flow to be observed, although this is dependent upon the operating pressure and gas velocity. 3 ORIFICE PLATE INSTALLATION AND TEST CONDITIONS Figure A Schematic Representation Of The TUV NEL Wet-Gas Test Facility For this test programme two 8-inch orifice plates (note that one plate was tested on two occasions, one after modification, due to an insufficiently sharp edge causing a high discharge coefficient) were installed in a holder with two pairs of flange tapping holes, designated A2/A and B2/B. The designation 2 refers to the upstream pressure tap while the designation refers to the downstream pressure tap. The tapping holes were 6 mm in diameter. For the dry-gas and wet-gas tests conducted the tapping-hole pairs were used in the following spatial arrangements, with the locations being defined relative to the upstream face of the plate: Project No: FFRE45 Page 6 of 39 April 2008

9 For the initial dry-gas baseline test of the β = 0.6 plate, where β is the diameter ratio, the A2/A tapping-hole pair was located in the o clock position and the B2/B tapping-hole pair was located in the 8 o clock position. For the β = 0.4 plate dry-gas baseline test, and the β = 0.4 and 0.6 plate wet-gas tests, the A2/A tapping-hole pair was located in the o clock position and the B2/B tapping-hole pair was located in the 0 o clock position. For the β = 0.42 and 0.6 (with drain hole) plates dry-gas baseline and wet-gas tests, the A2/A tapping-hole pair was located in the 2 o clock position and the B2/B tapping-hole pair was located in the 9 o clock position. Although the above shows that a number of different orientations were used for the orifice-plate holder during the baseline and wet-gas tests, it should be noted that the specific orientation used was of greatest importance during the drain-hole baseline and wet-gas test work. The drain hole was directly opposite the A2/A tapping-hole pair (and consequently at 90 o to the B2/B tapping-hole pair). Since the drain hole had to be located at the 6 o clock location to allow liquid to pass through it (i.e. at the bottom of the pipe) during wet-gas testing the A2/A tappings were then at the 2 o clock location and the B2/B tappings at the 9 o clock location. Each orifice plate was installed with 3D of matching pipe upstream (to the upstream face of the plate), and 8D of matching pipe downstream. A temperature probe was installed 6D downstream of the downstream face of the plate. Representative photographs of the installation are given in Figures 2 and 3 below. The upstream pipe diameter was mm, while the diameter of the two original orifice plates was 8.8 mm and 22.2 mm respectively (β = 0.4 and 0.6). The new diameter of the modified β = 0.4 plate was mm, giving a new diameter ratio of Both the dry and wet-gas tests were conducted at two static pressures, 20 and 60 bar gauge. This was done to obtain both a reasonable pipe Reynolds number range for the dry-gas tests, and to check for any effect of changing the gas-liquid density ratio on the orifice-plate over-reading performance. The dry-gas tests were conducted primarily as a baseline for the subsequent wet-gas test programme, but also to check the performance of the plates against the ISO 567 standard. The baselines are needed to allow the determination of the over-reading response of the orifice plates in the presence of a wet-gas flow. All calculations performed for the wet-gas data analysis are detailed in section 3. The orifice-plate dry-gas baseline tests were conducted over a number of slightly different ranges, dependent mainly on the orifice-plate diameter ratio (there are limits on pressure drop and maximum differential pressure), but also on the anticipated range of gas flow rates achievable on the test facility, given the required range of liquid injection rates at the two operating pressures in wet gas. It should also be noted that, in general, the gas flow rates used for the wet-gas tests are a subset of those used for the dry-gas baseline tests. The following summarises the gas flow rates used for each plate for both the dry and wet-gas tests: Diameter Ratio 0.4: 00, 200, 400, 600 and 800 Am 3 /hr. Diameter Ratio 0.42: 00, 200, 400, 600 and 800 Am 3 /hr, additionally 900 and 000 Am 3 /hr at 20 bar gauge only in dry-gas. Diameter Ratio 0.6: 200, 400, 600, 800, 000 and 200 Am 3 /hr, with and without the drain hole. Project No: FFRE45 Page 7 of 39 April 2008

10 The liquid flow rates used for the wet-gas tests were defined using the Lockhart-Martinelli parameter, a dimensionless number used for representing the liquid loading in a flow line. For this test programme the Lockhart-Martinelli parameter was set at the following values: 0, 0.0, 0.025, 0.05, 0.0, 0.5, 0.20, 0.25 and Figure 2 An Overview Of The Test Line Installation Figure 3 The 9 and 2 O clock Pressure Tapping Arrangement At The Orifice Plate Project No: FFRE45 Page 8 of 39 April 2008

11 4 RESULTS AND DISCUSSION The dry and wet-gas test measurements have been used to determine the orifice plate over-reading performance. The dry-gas discharge coefficients have been calculated using equation (), while a flow coefficient (a combination parameter which brings together the discharge coefficient, velocity of approach factor and expansibility) has been calculated using equation (2). Discharge, Cgas mgas = Eεgas Ad 2ρgas pgas () Flow, K gas = A m 2ρ gas p d gas gas (2) m gas is the reference gas mass flow rate, E is the velocity of approach factor 4 ( E = β ), β is the orifice plate diameter ratio, ε gas is the gas expansibility factor, A d is the throat area of the orifice plate, ρ gas is the gas density at the plate and p gas the measured dry-gas differential pressure. The dry-gas flow coefficient is a useful parameter when testing a differential-pressure meter in wet gas, in that it can be used to estimate what the differential pressure would be under wet-gas operating conditions if the gas flowed alone in the pipe (given knowledge of the reference gas mass flow rate), via the simple rearrangement of equation (2). This estimated dry-gas differential pressure can then be used to determine the over-reading of the differential pressure meter when combined with the measured wet-gas differential pressure ( p wet-gas ), as given in equation (3). Orifice Plate Over-Reading, φ = pwet gas pgas (3) The over-reading is simply a parameter which represents the extent to which the liquid presence in the flow line causes the measured differential pressure to increase relative to that which would be obtained if the line were completely dry. Differential-pressure meter over-readings are usually presented as a function of the Lockhart-Martinelli parameter (X), calculated here as defined in equation (4), and additionally as a function of the gas densiometric Froude number (Fr gas ) at the orifice plate location (equation (5)). Lockhart-Martinelli Parameter, mliquid X = mgas ρ ρ gas liquid (4) Gas Densiometric Froude Number, Fr gas = ρ gas m A gas D gd ρ ρ liquid gas ρ gas (5) where m liquid is the reference liquid mass flowrate, ρ liquid is the reference liquid density and D is the upstream pipe diameter, with A D being the corresponding upstream pipe area. Project No: FFRE45 Page 9 of 39 April 2008

12 The over-reading from the orifice plate can also be determined (for comparative purposes here) using a published model, such as that of Murdock [2] or Chisholm [3, 4]. The two models are given as equations (6) and (7, 8). Murdock Model Over-Reading, φ = +.26X (6) Chisholm Model Over-Reading, 2 φ = + CX + X (7) where ρgas ρliquid C = + when X ρ gas ρ liquid (8) 5 DRY-GAS BASELINE RESULTS The calculated dry-gas orifice-plate discharge and flow coefficients for each of the plates tested (both with and without drain holes), required for the subsequent wet-gas data analysis, are presented in Tables to 8. The flow coefficients presented in these tables have been used in the current analysis of the wet-gas data by obtaining a curve-fit to the values as a function of the pipe Reynolds number (also provided in the tables) calculated using the orifice plate upstream pipe diameter at the two test pressures used, i.e. 20 and 60 bar gauge. Other approaches can be used for estimating the flow coefficient (e.g. averaging the values), which would give slightly different over-reading results if used in the analysis. The Reynolds-number-based functions obtained from each orifice-plate dry-gas test are given in equations 9 to 24. These are presented in the same sequence as for the tables, with pairs of equations (e.g. 9 and 0) relating to the data taken at 20 and 60 bar gauge respectively for a given orifice plate and tapping-hole pair, A2/A first and B2/B second. Test Point No TABLE DIAMETER RATIO 0.4 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR A2/A Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar,.883e E E E E E E E E E E E E E E E E E E E Project No: FFRE45 Page 0 of 39 April 2008

13 TABLE 2 β = 0.4 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR B2/B Test Point No Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar,.883e E E E E E E E E E E E E E E E E E E E TABLE 3 β = 0.6 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR A2/A Test Point No Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 4.872E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.363e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.358e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.359e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.356e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.358e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.359e Project No: FFRE45 Page of 39 April 2008

14 TABLE 4 β = 0.6 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR B2/B Test Point No Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 4.872E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.363e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.358e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.359e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.356e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.358e xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx.359e TABLE 5 β = 0.42 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR A2/A Test Point No Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 2.454E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx Project No: FFRE45 Page 2 of 39 April 2008

15 TABLE 6 β = 0.42 ORIFICE-PLATE DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR B2/B Test Point No Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 2.454E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx Test Point No TABLE 7 β = 0.6 ORIFICE-PLATE (WITH DRAIN HOLE) DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR A2/A Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 2.949E E E E E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx Project No: FFRE45 Page 3 of 39 April 2008

16 Test Point No TABLE 8 β = 0.6 ORIFICE-PLATE (WITH DRAIN HOLE) DRY-GAS DISCHARGE AND FLOW COEFFICIENTS FOR TAPPING-HOLE PAIR B2/B Pipe Reynolds 20 bar 20 bar, C gas 20 bar, Pipe Reynolds 60 bar 60 bar, C gas 60 bar, 2.949E E E E E E E E E E E E E E E E E E E E E E E E E xxxxxxxxxx xxxxxxxxxx xxxxxxxxxx 3 2 = E 2.Re E 4.Re E 8.Re (9) 2 = E 6.Re E 0.Re (0) 3 2 = E 2.Re E 4.Re E 8.Re () 2 = E 6.Re E 0.Re (2) 2 = E 6.Re E 9.Re (3) 2 = E 7.Re E.Re (4) 2 = E 6.Re E 9.Re (5) 2 = E 7.Re E.Re (6) 3 2 = E 2.Re E 5.Re E 8.Re (7) 3 2 = E 23.Re E 6.Re E 9.Re (8) 3 2 = E 2.Re E 5.Re E 8.Re (9) 3 2 = E 23.Re E 6.Re E 9.Re (20) Project No: FFRE45 Page 4 of 39 April 2008

17 2 = 34505E 6.Re E 9.Re (2) 2 = E 7.Re E 0.Re (22) 2 = E 6.Re E 9.Re (23) 2 = E 7.Re E 2.Re (24) Figures 4 and 5 show the dry-gas discharge-coefficient results for the β = 0.4 orifice plate for the A2/A and B2/B tapping-hole pairs respectively. It is clear that both sets of coefficients lie outside the plotted ISO 567 uncertainty band. This indicated some problem with the manufacture of the orifice plate. Visual inspection of the plate showed that the orifice edge was insufficiently sharp; therefore this plate was modified to produce a slightly larger diameter ratio of 0.42, but with a much sharper edge. The results for the modified plate are presented in Figures 8 and 9. The discharge coefficient now lies on the ISO 567 calculated discharge coefficient, well within the acceptable uncertainty band. The discharge coefficient results for the β = 0.6 plate are given in Figures 6 and 7. The experimentally derived discharge coefficients lie between the lower ISO 567 uncertainty limit and the ISO calculated discharge coefficient value. Figures 0 and provide the dry-gas discharge coefficients for the β = 0.6 plate with the drain hole of diameter d h = 0.d. It is clear that the discharge coefficient has shifted in a positive direction relative to the non-drain-hole baseline tests, but by different extents for the A2/A and B2/B tapping-hole pairs. The shift is greater for the A2/A tapping-hole pair, with a mean shift relative to the baseline coefficient of 2.4%. For the B2/B tapping-hole pair this shift is of the order of.4% at the same pipe Reynolds number. The performance of the tapping-hole pairs is clearly sensitive to the relative location of the drain hole, with the largest effect seen when the tapping-hole pair is located at 80 o to the drain hole (i.e. the A2/A pair). At only 90 o to the drain hole position, the B2/B tapping-hole pair shows only 60% of the shift obtained from the A2/A tapping-hole pair. Project No: FFRE45 Page 5 of 39 April 2008

18 bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E+06 Pipe Reynolds Number Figure 4 β = 0.4 Orifice Plate Discharge Tapping-Hole Pair A2/A bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E+06 Pipe Reynolds Number Figure 5 β = 0.4 Orifice Plate Discharge Tapping-Hole Pair B2/B Project No: FFRE45 Page 6 of 39 April 2008

19 bar 60 bar 60 bar repeats ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E E E E+06 Pipe Reynolds Number Figure 6 β = 0.6 Orifice Plate Discharge Tapping-Hole Pair A2/A bar 60 bar 60 bar repeats ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E E E E+06 Pipe Reynolds Number Figure 7 β = 0.6 Orifice Plate Discharge Tapping-Hole Pair B2/B Project No: FFRE45 Page 7 of 39 April 2008

20 bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E+06 Pipe Reynolds No Figure 8 β = 0.42 Orifice Plate Discharge Tapping-Hole Pair A2/A bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E+06 Pipe Reynolds No Figure 9 β = 0.42 Orifice Plate Discharge Tapping-Hole Pair B2/B Project No: FFRE45 Page 8 of 39 April 2008

21 bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E E E E+06 Pipe Reynolds Number Figure 0 β = 0.6 Orifice Plate with Drain Hole Discharge Tapping-Hole Pair A2/A bar 60 bar ISO 567 Cd ISO 567 Uncertainty Discharge E+00.0E E E E E E E E E+06 Pipe Reynolds Number Figure β = 0.6 Orifice Plate with Drain Hole Discharge Tapping-Hole Pair B2/B Project No: FFRE45 Page 9 of 39 April 2008

22 6 WET-GAS RESULTS The calculated wet-gas over-readings for the tests conducted on the various orifice plates used here are presented in Figures 2 to 27 for both tapping-hole pairs, A2/A and B2/B. The figures provide the over-readings obtained as functions of the Lockhart-Martinelli parameter and the gas densiometric Froude number. It should be noted, however, that the gas test flow conditions were specified in terms of the actual volumetric flow rate. The figures also include the predictions of the Murdock [2] and Chisholm [3] models, as described in section 3, and these curves can be seen highlighted in red and blue respectively. The gas Froude number range presented on the graphs was from 0. to 5 for the β = 0.4 and 0.42 plates over the operating pressure range of the tests. For the β = 0.6 plate the gas Froude number range was 0.45 to.94. Previous data has suggested that below an upstream gas Froude number of.5, the over-reading will not change very much because the gas-liquid flow pattern is relatively unchanging, being either stratified or stratified-wavy with only minimal entrainment of the liquid in the gas flow. In the case of this test programme, most of the upstream gas Froude numbers used were below the.5 limiting value, with only two flow rates giving gas Froude numbers above.5 for the β = 0.6 orifice plate tests. It is, therefore, somewhat surprising that for both the β = 0.4 and 0.42 orifice plate results (Figures 2-5 and 20-23) there is such a strong gas Froude number effect, with over-readings at the limiting Lockhart-Martinelli parameter value of 0.3 in the approximate range.32 to.4 over a gas Froude number range of 0. to 0.65 at 20 bar gauge, and approximately.3 to.35 over a gas Froude number range of 0.9 to 5 at 60 bar gauge. The reason for the spread in the over-reading with gas Froude number is unknown. Small gas Froude numbers (and small steps in the gas Froude number) are producing significant spreads in the over-reading value at a given Lockhart-Martinelli parameter, where none would be expected. It may be that because of the damming effect of the orifice plate the over-reading continues to change as the gas Froude number reduces from.5. For the β = 0.6 plate tests (both with and without the drain hole: Figures 6-9 and 24-27) there is almost no observable gas Froude number effect. This behaviour is more consistent with expectations based on previously published data and the upstream gas Froude number range used. The difference between the data obtained using the β = 0.4 and 0.42 plates and those obtained using the β = 0.6 plate obviously requires some explanation. Tests at different diameter ratios may well need to be performed to determine the interpretation of the current data sets. Visualisation tests could prove useful in determining what is happening. On all of the figures the Chisholm model predictions tend to track the higher gas Froude number over-reading curves, while also accounting for the change in the gas-liquid density ratio. Murdock is a fixed over-reading function (only dependent on the Lockhart-Martinelli parameter), and so while the over-reading data set encompasses the Murdock model prediction at 20 bar gauge, it does not do so at 60 bar gauge. Based on this data set, using the Murdock model at high pressure (i.e. high gas-liquid density ratio) would therefore produce a significant overcorrection of the gas flow rate over the range of gas Froude numbers tested. Project No: FFRE45 Page 20 of 39 April 2008

23 .45.4 Orifice Plate Over-Reading Fr(gas)=0. Fr(gas)=0.2 Fr(gas)=0.43 Fr(gas)=0.54 Fr(gas)=0.65 Murdock Chisholm Lockhart-Martinelli Parameter Figure 2 β = 0.4 Orifice Plate, Tapping-Hole Pair A2/A Over-Reading Curves at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0. Fr(gas)=0.2 Fr(gas)=0.43 Fr(gas)=0.54 Fr(gas)=0.65 Murdock Chisholm Lockhart-Martinelli Parameter Figure 3 β = 0.4 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 20 Bar Gauge Project No: FFRE45 Page 2 of 39 April 2008

24 .45.4 Orifice Plate Over-Reading Fr(gas)=0.9 Fr(gas)=0.38 Fr(gas)=0.76 Fr(gas)=5 Murdock Chisholm Lockhart-Martinelli Parameter Figure 4 β = 0.4 Orifice Plate, Tapping-Hole Pair A2/A, Over-Reading Curves at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.9 Fr(gas)=0.38 Fr(gas)=0.76 Fr(gas)=5 Murdock Chisholm Lockhart-Martinelli Parameter Figure 5 β = 0.4 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 60 Bar Gauge Project No: FFRE45 Page 22 of 39 April 2008

25 .45.4 Orifice Plate Over-Reading Fr(gas)=0.45 Fr(gas)=0.67 Fr(gas)=0.89 Fr(gas)=2 Murdock Chisholm Lockhart-Martinelli Parameter Figure 6 β = 0.6 Orifice Plate, Tapping-Hole Pair A2/A, Over-Reading Curves at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.45 Fr(gas)=0.67 Fr(gas)=0.89 Fr(gas)=2 Murdock Chisholm Lockhart-Martinelli Parameter Figure 7 β = 0.6 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 20 Bar Gauge Project No: FFRE45 Page 23 of 39 April 2008

26 .45.4 Orifice Plate Over-Reading Fr(gas)=0.77 Fr(gas)=6 Fr(gas)=.55 Fr(gas)=.94 Murdock Chisholm Lockhart-Martinelli Parameter Figure 8 β = 0.6 Orifice Plate, Tapping-Hole Pair A2/A, Over-Reading Curves at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.77 Fr(gas)=6 Fr(gas)=.55 Fr(gas)=.95 Murdock Chisholm Lockhart-Martinelli Parameter Figure 9 β = 0.6 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 60 Bar Gauge Project No: FFRE45 Page 24 of 39 April 2008

27 .45.4 Orifice Plate Over-Reading Fr(gas)=0. Fr(gas)=0.22 Fr(gas)=0.44 Fr(gas)=0.66 Murdock Chisholm Lockhart-Martinelli Parameter Figure 20 β = 0.42 Orifice Plate, Tapping-Hole Pair A2/A, Over-Reading Curves at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0. Fr(gas)=0.22 Fr(gas)=0.44 Fr(gas)=0.66 Murdock Chisholm Lockhart-Martinelli Parameter Figure 2 β = 0.42 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 20 Bar Gauge Project No: FFRE45 Page 25 of 39 April 2008

28 .45.4 Orifice Plate Over-Reading Fr(gas)=0.9 Fr(gas)=0.38 Fr(gas)=0.77 Fr(gas)=7 Murdock Chisholm Lockhart-Martinelli Parameter Figure 22 β = 0.42 Orifice Plate, Tapping-Hole Pair A2/A, Over-Reading Curves at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.9 Fr(gas)=0.38 Fr(gas)=0.77 Fr(gas)=7 Murdock Chisholm Lockhart-Martinelli Parameter Figure 23 β = 0.42 Orifice Plate, Tapping-Hole Pair B2/B, Over-Reading Curves at 60 Bar Gauge Project No: FFRE45 Page 26 of 39 April 2008

29 .45.4 Orifice Plate Over-Reading Fr(gas)=0.43 Fr(gas)=0.65 Fr(gas)=0.87 Fr(gas)=.09 Murdock Chisholm Lockhart-Martinelli Parameter Figure 24 β = 0.6 Orifice Plate with Drain Hole, Tapping-Hole Pair A2/A, Over-Reading Curves at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.43 Fr(gas)=0.65 Fr(gas)=0.87 Fr(gas)=.09 Murdock Chisholm Lockhart-Martinelli Parameter Figure 25 β = 0.6 Orifice Plate with Drain Hole, Tapping-Hole Pair B2/B, Over-Reading Curves at 20 Bar Gauge Project No: FFRE45 Page 27 of 39 April 2008

30 .45.4 Orifice Plate Over-Reading Fr(gas)=0.76 Fr(gas)=5 Fr(gas)=.54 Fr(gas)=.93 Murdock Chisholm Lockhart-Martinelli Parameter Figure 26 β = 0.6 Orifice Plate with Drain Hole, Tapping-Hole Pair A2/A, Over-Reading Curves at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Fr(gas)=0.76 Fr(gas)=5 Fr(gas)=.54 Fr(gas)=.93 Murdock Chisholm Lockhart-Martinelli Parameter Figure 27 β = 0.6 Orifice Plate with Drain Hole, Tapping-Hole Pair B2/B, Over-Reading Curves at 60 Bar Gauge Project No: FFRE45 Page 28 of 39 April 2008

31 7 DENSITY RATIO, DIAMETER-RATIO AND DRAIN HOLE EFFECTS As has been seen with other differential pressure meters, there is a small but clear effect of the gas-liquid density ratio on the over-reading obtained from an orifice plate. Figures show the orifice plate over-reading data rearranged to compare any effect of the gas-liquid density ratio that may be present. For both the β = 0.4 and 0.42 orifice plate tests (Figures 28, 29, 32 and 33) the spread in the over-reading data obscures the effect of the density ratio to some extent, but there is definitely a small effect present, showing itself as a reduction in the over-reading as the density ratio increases. For the β = 0.6 plate results (both with and without the drain hole; Figures 30, 3, 34 and 35), there is a clearer effect of the density ratio on the over-reading performance of the orifice plate, primarily due to the lack of an observed gas Froude number effect on the over-reading. There is also a noticeable effect of the tapping-hole pair location for the β = 0.6 plate. The A2/A tapping-hole pair has larger over-readings (particularly at 20 bar gauge) than the B2/B tapping pair at the same Lockhart-Martinelli parameter value. Figures 36 to 39 were created to help to determine if there is a clear effect of the orifice-plate diameter ratio on the observed over-readings. The data for all four wet-gas test runs have been included on the figures, and the individual data sets have had quadratic functions fitted through them to allow comparisons of the means of the data sets. However, comparison is still not that straightforward as for the nominally two diameter ratios used the gas Froude number ranges are different. A cursory examination of the figures shows that there is a diameter-ratio effect in evidence, but it is small and not particularly consistent. Looking at the data in more detail, in Figure 36 there is a noticeable separation at 20 bar gauge between the fitted curves for the β = 0.6 orifice plate, with and without the drain hole for the A2/A tapping-hole pair. There is also a separation between the β = 0.6 and 0.4/0.42 fitted curves, with the β = 0.6 plate curves having larger over-readings than the 0.4/0.42 plate curves. It should be noted, however, that this conclusion might be different if it were possible to test the 0.4/0.42 and 0.6 orifice plates over the same gas Froude number range. It is also noticeable that the β = 0.4/0.42 fits are almost identical. For the equivalent results for the B2/B tapping-hole pair (Figure 37), there does not appear to be much of an effect observable; however, this seems to be partly due to the fact that the results with the drain hole are much closer to those without a drain hole for the B2/B tapping-hole pair than for the A2/A tapping-hole pair. Differences between the fitted over-reading curves (and by inference the diameter ratio effect) are seen to reduce further at 60 bar gauge (Figures 38 and 39), mainly highlighting how the gas-liquid density ratio effect is causing the over-reading data both to both reduce in value and to converge, indicating a diminishing influence of diameter ratio as the gas-liquid density ratio increases. Although the effect is reducing, it is clear that an effect of diameter ratio appears to be present, particularly for the A2/A tapping-hole pair data sets. Again, the convergence of the data is partly due to the fact that the results with the drain hole are much closer to those without a drain hole for the B2/B tapping-hole pair than for the A2/A tapping hole. Project No: FFRE45 Page 29 of 39 April 2008

32 .45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 28 Effect of Gas-Liquid Density Ratio for the β = 0.4 Orifice Plate and the A2/A Tapping-Hole Pair.45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 29 Effect of Gas-Liquid Density Ratio for the β = 0.4 Orifice Plate and the B2/B Tapping-Hole Pair Project No: FFRE45 Page 30 of 39 April 2008

33 .45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 30 Effect of Gas-Liquid Density Ratio for the β = 0.6 Orifice Plate and the A2/A Tapping-Hole Pair.45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 3 Effect of Gas-Liquid Density Ratio for the β = 0.6 Orifice Plate and the B2/B Tapping-Hole Pair Project No: FFRE45 Page 3 of 39 April 2008

34 .45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 32 Effect of Gas-Liquid Density Ratio for the β = 0.42 Orifice Plate and the A2/A Tapping-Hole Pair.45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 33 Effect of Gas-Liquid Density Ratio for the β = 0.42 Orifice Plate and the B2/B Tapping-Hole Pair Project No: FFRE45 Page 32 of 39 April 2008

35 .45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 34 Effect of Gas-Liquid Density Ratio for the β = 0.6 Orifice Plate with a Drain Hole and the A2/A Tapping-Hole Pair.45.4 Orifice Plate Over-Reading bar gauge 60 bar gauge Lockhart-Martinelli Parameter Figure 35 Effect of Gas-Liquid Density Ratio for the β = 0.6 Orifice Plate with a Drain Hole and the B2/B Tapping-Hole Pair Project No: FFRE45 Page 33 of 39 April 2008

36 .45.4 Orifice Plate Over-Reading Beta 0.4 Beta 0.6 Beta 0.42 Beta 0.6 Drain Hole Lockhart-Martinelli Parameter Figure 36 Effect of Diameter Ratio for the Four Plates Tested for Tapping-Hole Pair A2/A at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Beta 0.4 Beta 0.6 Beta 0.42 Beta 0.6 Drain Hole Lockhart-Martinelli Parameter Figure 37 Effect of Diameter Ratio for the Four Plates Tested for Tapping-Hole Pair B2/B at 20 Bar Gauge Project No: FFRE45 Page 34 of 39 April 2008

37 .45.4 Orifice Plate Over-Reading Beta 0.4 Beta 0.6 Beta 0.42 Beta 0.6 Drain Hole Lockhart-Martinelli Parameter Figure 38 Effect of Diameter Ratio for the Four Plates Tested for Tapping-Hole Pair A2/A at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Beta 0.4 Beta 0.6 Beta 0.42 Beta 0.6 Drain Hole Lockhart-Martinelli Parameter Figure 39 Effect of Diameter Ratio for the Four Plates Tested for Tapping-Hole Pair B2/B at 60 Bar Gauge Project No: FFRE45 Page 35 of 39 April 2008

38 8 THE EFFECT OF THE DRAIN HOLE The effect of the presence of the drain hole is shown in Figures 40 to 43, which present the over-reading data for the β = 0.6 plate. On the whole, for a given tapping-hole pair the effect can be seen to be quite small, with the A2/A tapping-hole pair showing the larger differences in over-reading. Reviewing the figures, it is debatable whether or not a maximum average relative error of.2% can be considered to constitute a significant and real shift in the performance of the plate due to the drain hole, since the over-readings with pairs of tappings in only slightly different orientations without a drain hole can differ by a similar magnitude. Project No: FFRE45 Page 36 of 39 April 2008

39 .45.4 Orifice Plate Over-Reading Baseline Drain Hole Lockhart-Martinelli Parameter Figure 40 Comparison of the Baseline and Drain Hole Over-Readings for Tapping-Hole Pair A2/A at 20 Bar Gauge.45.4 Orifice Plate Over-Reading Baseline Drain Hole Lockhart-Martinelli Parameter Figure 4 Comparison of the Baseline and Drain Hole Over-Readings for Tapping-Hole Pair B2/B at 20 Bar Gauge Project No: FFRE45 Page 37 of 39 April 2008

40 .45.4 Orifice Plate Over-Reading Baseline Drain Hole Lockhart-Martinelli Parameter Figure 42 Comparison of the Baseline and Drain Hole Over-Readings for Tapping-Hole Pair A2/A at 60 Bar Gauge.45.4 Orifice Plate Over-Reading Baseline Drain Hole Lockhart-Martinelli Parameter Figure 43 Comparison of the Baseline and Drain Hole Over-Readings for Tapping-Hole Pair B2/B at 60 Bar Gauge Project No: FFRE45 Page 38 of 39 April 2008

41 9 CONCLUSIONS In dry gas, the presence of a drain hole shifted the orifice plate discharge coefficient in a positive direction by 2.4% for the A2/A tapping-hole pair and.4% for the B2/B tapping-hole pair. This is consistent with the shifts determined from tests both in water (on 8-inch orifice plates) and on a series of 4-inch orifice plates also tested in water and in dry gas []. In wet gas, the orifice plate over-readings corresponded more closely with the Chisholm model than the Murdock model, with the Chisholm model tracking the gas-liquid density ratio effect on the over-reading, particularly at the high end of the gas Froude number ranges tested. For the β = 0.6 plate no effect of the gas Froude number on the over-reading was found, which is consistent with the concept that below a gas Froude number of.5, the upstream gas-liquid flow pattern is of the stratified type, which should not vary significantly as the Froude number decreases below.5. However, this behaviour was not obtained from the β = 0.42 (and 0.4) plates, where larger spreads in over-reading were measured, particularly at the lower gas-liquid density ratio tested, over an upstream gas Froude number range smaller than that for the β = 0.6 plate. The reason for the behaviour of the smaller diameter-ratio plate is unknown. Further work is required. Differences in the β = 0.6 orifice-plate over-reading were also found between the A2/A and B2/B tapping-hole pairs, of the order of 2.4% at 20 bar gauge and within % at 60 bar gauge. No differences were obtained from the β = 0.4 (and 0.42) plate. It has also been found that the presence of a drain hole causes a small increase in over-reading relative to a plate with no drain hole. REFERENCES READER-HARRIS, M. J., and BARTON, N. The effect of drain holes in orifice plates on the discharge coefficient. TUV NEL Report No on Project No FFRE45. East Kilbride, Glasgow: NEL, MURDOCK, J. W. Two-Phase Flow Measurement with Orifices. Journal of Basic Engineering, pp , CHISHOLM, D. Flow of Incompressible Two-Phase Mixtures through Sharp- Edged Orifices. Journal of Mechanical Engineering Science, 9, No., CHISHOLM, D. Research Note: Two-Phase Flow through Sharp-Edged Orifices. Journal of Mechanical Engineering Science, 9, No. 3, 977. Project No: FFRE45 Page 39 of 39 April 2008

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE Acadiana Flow Measurement Society Gerald L. Morrison Presented by: Mechanical Engineering Department Daniel J. Rudroff 323 Texas A&M University Flowline Meters

More information

Measurement & Analytics Wet gas monitoring

Measurement & Analytics Wet gas monitoring Product guide PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring Economical wet gas metering using non-proprietary correlations Measurement made easy Introduction With many of the most economically

More information

The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for

The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for National Measurement System Directorate Department of Trade & Industry 151 Buckingham Palace Road London, SW1W 9SS Report No: 2002/100

More information

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration Paper 2.2 Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration Mr William Freund, Daniel Measurement and Control Mr Klaus Zanker, Daniel Measurement and Control Mr Dale Goodson,

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

Wet Gas Flowmetering Guideline

Wet Gas Flowmetering Guideline Wet Gas Flowmetering Guideline ASME MFC-19G 2008 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS Three Park Avenue New York, New York 10016-5990 CONTENTS Foreword... v Standards Committee Roster... vi 1 Introduction...

More information

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Rubens Silva Telles 1, Kazuto Kawakita 2 1 IPT Instituto de Pesquisas Tecnológicas, São Paulo, Brazil, rtelles@ipt.br

More information

Wet Gas Measurement Using an etube Flow Meter

Wet Gas Measurement Using an etube Flow Meter Wet Gas Measurement Using an etube Flow Meter Brian Zerb, Zedi Inc. Edmonton, AB Introduction Wet metering of natural gas has been increasing in demand. As well productions decline and flow rates of new

More information

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller. Centrifugal pump How centrifugal pumps work A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller. In centrifugal pump, liquid is forced

More information

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES: SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids

More information

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE Proceedings of the 37 th International & 4 th National Conference on Fluid Mechanics and Fluid Power FMFP2010 December 16-18, 2010, IIT Madras, Chennai, India FMFP2010 341 MODELING AND SIMULATION OF VALVE

More information

OIL AND GAS INDUSTRY

OIL AND GAS INDUSTRY This case study discusses the sizing of a coalescer filter and demonstrates its fouling life cycle analysis using a Flownex model which implements two new pressure loss components: - A rated pressure loss

More information

Micro Motion Pressure Drop Testing

Micro Motion Pressure Drop Testing 12/2018 Micro Motion Pressure Drop Testing www.emerson.com/micromotion Introduction Micro Motion has traditionally taken a very conservative approach to pressure drop, with single pressure measurements

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility Jos G.M. van der Grinten, NMi EuroLoop Bart van der Stap, Flowways Dick van Driel, Krohne Abstract The operational experiences

More information

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 143/AGA REPORT NO 3 - PART2 Paul J LaNasa CPL & Associates PO Box 801304, Houston, TX 77280-1304 ABSTRACT Periodically, natural gas measurement standards

More information

Experiment 8: Minor Losses

Experiment 8: Minor Losses Experiment 8: Minor Losses Purpose: To determine the loss factors for flow through a range of pipe fittings including bends, a contraction, an enlargement and a gate-valve. Introduction: Energy losses

More information

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics Large Hadron Collider Project LHC Project Report 684 SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG

More information

EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS

EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS Alistair Collins, Dr. Mark Tudge, Carol Wade (Solartron ISA) [we are] dwarfs perched on the shoulders of giants...we see more

More information

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes. Piping Tutorial A piping network represents the flow of fluids through several pieces of equipment. If sufficient variables (flow rate and pressure) are specified on the piping network, CHEMCAD calculates

More information

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

International Journal of Technical Research and Applications e-issn: ,  Volume 4, Issue 3 (May-June, 2016), PP. DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008

More information

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow Aidan O'Donoghue, Pipeline Research Limited, Glasgow, UK This paper sets out to provide an initial method of assessing the bypass requirements

More information

Oil And Gas Office Houston Fax Test Separator / Off-Shore Metering

Oil And Gas Office Houston Fax Test Separator / Off-Shore Metering Oil And Gas Office Houston 281 361 0708 Fax 201 361 0708 Test Separator / Off-Shore Metering Prepared By : Mr. Phil Lawrence A. M. Inst Mech E. Sales Manager (Oil and Gas Industry) 2.0 Philosophy for Test

More information

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory 1 MEMORANDUM TO: FROM: Prof. Davis Hubbard Prof. Faith A. Morrison DATE: 22 April 2014 RE: Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory Introduction

More information

Drilling Efficiency Utilizing Coriolis Flow Technology

Drilling Efficiency Utilizing Coriolis Flow Technology Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities

More information

Gerald D. Anderson. Education Technical Specialist

Gerald D. Anderson. Education Technical Specialist Gerald D. Anderson Education Technical Specialist The factors which influence selection of equipment for a liquid level control loop interact significantly. Analyses of these factors and their interactions

More information

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,

More information

Pressure is defined as force per unit area. Any fluid can exert a force

Pressure is defined as force per unit area. Any fluid can exert a force Physics Notes Chapter 9 Fluid Mechanics Fluids Fluids are materials that flow, which include both liquids and gases. Liquids have a definite volume but gases do not. In our analysis of fluids it is necessary

More information

Heat Pump Connections and Interior Piping

Heat Pump Connections and Interior Piping Job Sheet 3 Heat Pump Connections and Interior Piping OBJECTIVES In this job sheet, you will observe how the presence of air in the ground loop affects the geothermal heat pump performance. You will also

More information

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler C. Becnel, J. Lagrone, and K. Kelly Mezzo Technologies Baton Rouge, LA USA 70806 ABSTRACT The Missile Defense Agency has supported a research

More information

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK ABSTRACT Ventilation stacks are becoming increasingly common in the design of naturally

More information

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS - 56 - CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS Gloth O., Rudolf A. ILF Consulting Engineers Zürich, Switzerland ABSTRACT This article investigates the

More information

485 Annubar Primary Flow Element Installation Effects

485 Annubar Primary Flow Element Installation Effects ROSEMOUNT 485 ANNUBAR 485 Annubar Primary Flow Element Installation Effects CONTENTS Mounting hole diameter Alignment error Piping Geometry Induced Flow Disturbances Pipe reducers and expansions Control

More information

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models RESEARCH ARTICLE Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models M. SREENIVASULU REDDY 1 DR Y. RAMALINGA REDDY 2 Assistant Professor, School of

More information

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Application of Computational Fluid Dynamics to Compressor Efficiency Improvement J.

More information

An Investigation of Liquid Injection in Refrigeration Screw Compressors

An Investigation of Liquid Injection in Refrigeration Screw Compressors An Investigation of Liquid Injection in Refrigeration Screw Compressors Nikola Stosic, Ahmed Kovacevic and Ian K. Smith Centre for Positive Displacement Compressor Technology, City University, London EC1V

More information

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007 Overview ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007 ProSoft Technology s Gas and Liquid Flow Computer (AFC) products will comply with the requirements

More information

Experiment Instructions. Circulating Pumps Training Panel

Experiment Instructions. Circulating Pumps Training Panel Experiment Instructions Circulating Pumps Training Panel Experiment Instructions This manual must be kept by the unit. Before operating the unit: - Read this manual. - All participants must be instructed

More information

Aberdeen Significant Error Review ITE Independent Report. Eur Ing Keith Vugler CEng FInstMC

Aberdeen Significant Error Review ITE Independent Report. Eur Ing Keith Vugler CEng FInstMC 1 Aberdeen Significant Error Review ITE Independent Report 331 Eur Ing Keith Vugler CEng FInstMC 2 Previous Presentation Summary My previous presentation (16 th July 2012) provided; an introduction to

More information

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B By Kimbal A. Hall, PE Submitted to: WESTFALL MANUFACTURING COMPANY September 2009 ALDEN RESEARCH LABORATORY, INC.

More information

Hours / 100 Marks Seat No.

Hours / 100 Marks Seat No. 17421 15116 3 Hours / 100 Seat No. Instructions (1) All Questions are Compulsory. (2) Answer each next main Question on a new page. (3) Illustrate your answers with neat sketches wherever necessary. (4)

More information

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES M. R. Marshall* and P. L. Stewart-Darling* A simple mathematical model for the buoyancy driven ventilation of an enclosed space, using a two-pipe

More information

Test on a Twin-Screw Compressor

Test on a Twin-Screw Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1996 Test on a Twin-Screw Compressor C. Ducruet Electricite de France B. Hivet Electricite

More information

Tutorial. BOSfluids. Relief valve

Tutorial. BOSfluids. Relief valve Tutorial Relief valve The Relief valve tutorial describes the theory and modeling process of a pressure relief valve or safety valve. It covers the algorithm BOSfluids uses to model the valve and a worked

More information

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that: University Physics (Prof. David Flory) Chapt_15 Thursday, November 15, 2007 Page 1 Name: Date: 1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that: A) pressure is the same

More information

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12 LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/ This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the rates with which selected

More information

FAQs about Directive 017

FAQs about Directive 017 FAQs about Directive 017 General What measurement points are covered in this directive? The requirements in this directive cover all measurement points required by the Oil and Gas Conservation Regulations

More information

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler To cite this article: Jinglong Liu et al 2018

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 5167-5 First edition 2016-03-01 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 5: Cone meters

More information

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Cover Page for Lab Report Group Portion. Head Losses in Pipes Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section

More information

H16 Losses in Piping Systems

H16 Losses in Piping Systems H16 Losses in Piping Systems The equipment described in this manual is manufactured and distributed by TECQUIPMENT LIMITED Suppliers of technological laboratory equipment designed for teaching. BONSALL

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 1 CHAPTER 5 SELECTION CRITERIA FOR SAFETY VALVES CALCULATION OF THE DISCHARGE CAPACITY (Ref. EN 13136:2013) The evaluation of the minimum required discharge capacity of safety valves

More information

Operational Settings:

Operational Settings: instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of

More information

An innovative technology for Coriolis metering under entrained gas conditions

An innovative technology for Coriolis metering under entrained gas conditions An innovative technology for Coriolis metering under entrained gas conditions Coriolis mass flowmeters are usually only used for single-phase fluids, i.e. either liquids or gases, since it has been found

More information

MODELLING OF FUME EXTRACTORS C. R.

MODELLING OF FUME EXTRACTORS C. R. LD8 19th International Symposium of Ballistics, 7 11 May 21, Interlaken, Switzerland MODELLING OF FUME EXTRACTORS C. R. Woodley WS4 Guns and Warheads Department, Defence Evaluation and Research Agency,

More information

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Sophie

More information

EDUCTOR. principle of operation

EDUCTOR. principle of operation EDUCTOR principle of operation condensate and mixing eductor s are designed to mix two liquids intimately in various proportions in operations where the pressure liquid is the greater proportion of the

More information

Process Dynamics, Operations, and Control Lecture Notes - 20

Process Dynamics, Operations, and Control Lecture Notes - 20 Lesson 0. Control valves 0.0 Context Controller output is a signal that varies between 0 and 100%. Putting this signal to use requires a final control element, a device that responds to the controller

More information

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018 ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018 Section 1.2 Example. The discharge in a channel with bottom width 3 m is 12 m 3 s 1. If Manning s n is 0.013 m -1/3 s and the streamwise slope is 1 in 200,

More information

Traceable calibration of automatic weighing instruments in dynamic operation

Traceable calibration of automatic weighing instruments in dynamic operation Traceable calibration of automatic weighing instruments in dynamic operation Matej Grum* Metrology Institute of the Republic of Slovenia, Grudnovo nabrežje 17, 1000 Ljubljana, Slovenia Abstract. The article

More information

Two-phase Flow Across Small Diameter Split U-type Junctions

Two-phase Flow Across Small Diameter Split U-type Junctions Proceedings of Fifth International Conference on Enhanced, Compact and Ultra-Compact Heat Echangers: Science, Engineering and Technology, Eds. R.K. Shah, M. Ishizuka, T.M. Rudy, and V.V. Wadekar, Engineering

More information

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain A New iston Gauge to Improve the Definition of High Gas ressure and to Facilitate the Gas to Oil Transition in a ressure Calibration Chain ierre Delajoud, Martin Girard DH Instruments, Inc. 4765 East Beautiful

More information

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water Hong Xu, Chokri Guetari ANSYS INC. Abstract Transient numerical simulations of the rise of a train of gas bubbles in a liquid

More information

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow A model to examine pigging and inspection of gas networks with multiple pipelines, connections and

More information

Experiment (13): Flow channel

Experiment (13): Flow channel Experiment (13): Flow channel Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface

More information

Part 6: Critical flow orifices

Part 6: Critical flow orifices Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6145-6 Third edition 2017-07 Gas analysis Preparation of calibration gas mixtures using dynamic methods Part 6: Critical flow orifices Analyse

More information

Third measurement MEASUREMENT OF PRESSURE

Third measurement MEASUREMENT OF PRESSURE 1. Pressure gauges using liquids Third measurement MEASUREMENT OF PRESSURE U tube manometers are the simplest instruments to measure pressure with. In Fig.22 there can be seen three kinds of U tube manometers

More information

BY THOMAS M. WALSKI, BRIAN LUBENOW, AND JEFFREY SPAIDE. When they install a branch from a water distribution main,

BY THOMAS M. WALSKI, BRIAN LUBENOW, AND JEFFREY SPAIDE. When they install a branch from a water distribution main, BY THOMAS M. WALSKI, BRIAN LUBENOW, AND JEFFREY SPAIDE When they install a branch from a water distribution main, water utility managers often debate the benefits of using a tap as opposed to shutting

More information

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

More information

Accurate Measurement Guidelines

Accurate Measurement Guidelines Introduction This standard is designed to provide production operations personnel with detail information concerning Fieldwood's Measurement Standard Operating Procedures. Included are the following: Meter

More information

Bioreactor System ERT 314. Sidang /2011

Bioreactor System ERT 314. Sidang /2011 Bioreactor System ERT 314 Sidang 1 2010/2011 Chapter 2:Types of Bioreactors Week 4 Flow Patterns in Agitated Tanks The flow pattern in an agitated tank depends on the impeller design, the properties of

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their

More information

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1

A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1 A Computational Assessment of Gas Jets in a Bubbly Co-Flow 1 Melissa Fronzeo*, 1 Michael Kinzel 1 The Pennsylvania State University, University Park, PA, USA Abstract In this effort, Computational Fluid

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary ADH 1/7/014 LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the

More information

Accurate Measurement of Steam Flow Properties

Accurate Measurement of Steam Flow Properties Accurate Measurement of Steam Flow Properties Kewen Li and Roland N. Horne Stanford Geothermal Program, Stanford University (Proceedings of 1999 GRC Annual Meeting on October 17-20, Reno, California, USA)

More information

44 (0) E:

44 (0) E: FluidFlow Relief Valve Sizing Handbook Flite Software 2016 Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd, Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 E: sales@fluidflowinfo.com

More information

GOOD PRACTICE GUIDE AN INTRODUCTION TO FLOW METER INSTALLATION EFFECTS

GOOD PRACTICE GUIDE AN INTRODUCTION TO FLOW METER INSTALLATION EFFECTS GOOD PRACTICE GUIDE AN INTRODUCTION TO FLOW METER INSTALLATION EFFECTS www.tuvnel.com An Introductory Guide to Flow Meter Installation Effects The aim of this Good Practice Guide is to introduce the subject

More information

Instruction Manual. Pipe Friction Training Panel

Instruction Manual. Pipe Friction Training Panel Instruction Manual HL 102 Pipe Friction Training Panel 100 90 80 70 60 50 40 30 20 10 HL 102 Instruction Manual This manual must be kept by the unit. Before operating the unit: - Read this manual. - All

More information

THE WAY THE VENTURI AND ORIFICES WORK

THE WAY THE VENTURI AND ORIFICES WORK Manual M000 rev0 03/00 THE WAY THE VENTURI AND ORIFICES WORK CHAPTER All industrial combustion systems are made up of 3 main parts: ) The mixer which mixes fuel gas with combustion air in the correct ratio

More information

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL OIML R 32 RECOMMENDATION Edition 1989 (E) Rotary piston gas meters and turbine gas meters Compteurs de volume de gaz à pistons rotatifs et compteurs de volume de gaz à turbine OIML R 32 Edition

More information

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter Kjell-Eivind Frøysa, Christian Michelsen Research AS, Bergen, Norway Henning Ekerhovd, StatoilHydro ASA, Kollsnes, Norway

More information

DNVGL-CP-0187 Edition March 2016

DNVGL-CP-0187 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0187 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Gas Gathering System Modeling The Pipeline Pressure Loss Match

Gas Gathering System Modeling The Pipeline Pressure Loss Match PETROLEUM SOCIETY CANADIAN INSTITUTE OF MINING, METALLURGY & PETROLEUM PAPER 2005-230 Gas Gathering System Modeling The Pipeline Pressure Loss Match R.G. MCNEIL, P.ENG. Fekete Associates Inc. D.R. LILLICO,

More information

Smoke and heat Ventilator Testing

Smoke and heat Ventilator Testing Instituut vir Termodinamika en Meganika Institute for Thermodynamics and Mechanics Smoke and heat Ventilator Testing by CJ Zietsman and GR Smith November 2005 Departement Meganiese Ingenieurswese Privaat

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

International Journal of Research in Advent Technology Available Online at:

International Journal of Research in Advent Technology Available Online at: Volume, Issue 5, December 23 AN APPROACH TO DEVELOPMENT OF AIR LEAKAGE TEST RIG FOR AIR HANDLING UNITS HOUSING. Deepak Singh Asst. Professor, Department of Mechanical Engineering Kautilya Institute of

More information

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION Engineering MECHANICS, Vol. 20, 2013, No. 3/4, p. 213 220 213 AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION Václav Dvořák* The article deals with axial-symmetric subsonic air-to-air

More information

Equation 1: F spring = kx. Where F is the force of the spring, k is the spring constant and x is the displacement of the spring. Equation 2: F = mg

Equation 1: F spring = kx. Where F is the force of the spring, k is the spring constant and x is the displacement of the spring. Equation 2: F = mg 1 Introduction Relationship between Spring Constant and Length of Bungee Cord In this experiment, we aimed to model the behavior of the bungee cord that will be used in the Bungee Challenge. Specifically,

More information

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE 22 CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE 2.1 EXPERIMENTAL COLUMN All the experiments were carried out in an internal loop airlift fluidized bed and combined loop fluidized bed (an external down comer

More information

3 1 PRESSURE. This is illustrated in Fig. 3 3.

3 1 PRESSURE. This is illustrated in Fig. 3 3. P = 3 psi 66 FLUID MECHANICS 150 pounds A feet = 50 in P = 6 psi P = s W 150 lbf n = = 50 in = 3 psi A feet FIGURE 3 1 The normal stress (or pressure ) on the feet of a chubby person is much greater than

More information

FAQs about Directive PNG017: Measurement Requirements for Oil and Gas Operations

FAQs about Directive PNG017: Measurement Requirements for Oil and Gas Operations FAQs about Directive PNG017: Measurement Requirements for Oil and Gas Operations General Is it acceptable to report no gas production? All associated gas (gas produced from an oil well) or non-associated

More information

General Accreditation Guidance. User checks and maintenance of laboratory balances

General Accreditation Guidance. User checks and maintenance of laboratory balances General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in

More information

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment

More information

"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group "BS7965 2013 - An overview of updates to the previous ( 2009 ) edition Andrew Wrath & BS7965 Working Group BS7965:2013 Guide to the selection, installation, operation and calibration of diagonal path transit

More information

Gas measurement for the real world

Gas measurement for the real world V-Cone meter : Gas measurement for the real world Maron J. Dahlstrøm Phillips Petroleum Company Norway Summary This paper describes the performance of the V-Cone meters used for Embla test separator gas

More information

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION S. Pindado, J. Meseguer, J. M. Perales, A. Sanz-Andres and A. Martinez Key words: Wind loads, bridge construction, yawing moment. Abstract.

More information

3. GRADUALLY-VARIED FLOW (GVF) AUTUMN 2018

3. GRADUALLY-VARIED FLOW (GVF) AUTUMN 2018 3. GRADUALLY-VARIED FLOW (GVF) AUTUMN 2018 3.1 Normal Flow vs Gradually-Varied Flow V 2 /2g EGL (energy grade line) Friction slope S f h Geometric slope S 0 In flow the downslope component of weight balances

More information