DHR40 LED TECHNICAL MANUAL

Size: px
Start display at page:

Download "DHR40 LED TECHNICAL MANUAL"

Transcription

1 DHR0 LED TECHNICAL MANUAL SIN CE 9 Den Haan Rotterdam

2 TABLE OF CONTENTS Disclaimer Technical data Dimensions Available models Exploded view - base mounting Exploded view - side mounting Exploded view - retrofit Exploded view - hoistable Electrical specification Lifetime Control Positioning sidelights Positioning all-round lights Mounting Page Page Page Page Page Page Page Page 9 Page 0 Page 0 Page Page Page DISCLAIMER Den Haan Rotterdam B.V. is not responsible or liable for (in)direct or consequential damages from the use or application of this equipment and manual. All illustrations in this manual are for illustrative purposes only. This manual is not intended to cover every possible detail about the product and its maintenance. Den Haan Rotterdam B.V. does not assume responsibility or reliability for actual use based on the text, illustrations and diagrams. Copyright, Den Haan Rotterdam B.V. Version.0 December 0 This document contains proprietary information that is protected by copyright. All rights reserved.

3 TECHNICAL DATA Application: Ÿ For all sea-going vessels with a length of less than 0 metres Ÿ Rhine and European inland navigation Construction: Ÿ According to International Regulations for Preventing Collisons at Sea; COLREG and latest amendments Ÿ Conform Rhine and European inland navigation rules Ÿ In compliance with the Directives 9/9/EC and //EC, following the European standard: EN (00) AC(00), Inland navigation vessels and sea-going vessels navigation light Materials: Ÿ Housing: Seawater resistant aluminium, hard anodised, matt black Ÿ LED driver: epoxy potted Ÿ Screen: Seawater resistant aluminium, hard anodised Ÿ Lens: Borosilicate glass Ÿ Base: Delrin black Min. visibilty: Sector lights Starboard - bright Port - bright Masthead - bright Stern - bright Towing - bright NM NM NM NM NM All-round - bright - bright - bright - bright - bright Electrical insulation class: I, (grounded) / III Powersupply: VDC -0% +0% Protection class: IP X life time: 0,000 Hours Operation temperature: - C up to + C Mounting: Base, side or hoistable NM NM NM NM NM

4 DIMENSIONS Base mounting 9 0 Ø Ø PG9 Side mounting Ø0 0 Pg9 Ø Ø0 M Retrofit Ø The DHR0 Retrofit is designed to easily screw it in the original DHR mounting base with bajonet socket. This makes your navigation light the most easy upgrade ever done. The mounting base is not included, because it is already on the vessel. If not, then the DHR0 base mounted version is recommended. Hoistable 0 Appr. PG9 All dimensions in mm.

5 AVAILABLE MODELS Base Mounted Sector lights Min. Visibility Colour Power Art. Code Starboard Port Masthead Stern Towing NM All-round lights Min. Visibility Colour Sector lights Min. Visibility Colour Power Art. Code Starboard Port Masthead Stern Towing NM All-round lights Min. Visibility Colour All-round lights Min. Visibility Colour Art. Code Side Mounted Retrofit Art. Code Hoistable Art. Code

6 EXPLODED VIEW - BASE MOUNTING 9 0 Item Part Material Cover Gasket DHR0 Glass Tube Screen side lights masthead stern Heatsink triangle LED PCB (Starboard / ) (Port / red) (Masthead / Stern / ) (Towing / ) Housing Side and Base LED driver O-Ring DHR0 Base plate Cable gland Pg 9 Membrane Vent Neoprene - shore 0 Borosilicate glass Seawater resistant aluminium, hard anodized 9 0 Quantity Seawater resistant aluminium MC-PCB, aluminum. mm Led platinum dragon PCB - Potting matrial: Polyurethaan Neoprene - shore 0 Delrin black Body: Polyamide - Seal: Neoprene Body: Silicone rubber - Membrane: eptfe Number

7 EXPLODED VIEW - SIDE MOUNTING 9 0 Item Part Material Quantity Neoprene - shore 0 Borosilicate glass Seawater resistant aluminium, hard anodized Cover Gasket DHR0 Glass Tube Screen side lights masthead stern Heatsink triangle LED PCB Seawater resistant aluminium MC-PCB, aluminum. mm 9 0 (Starboard / ) (Port / red) (Masthead / Stern / ) (Towing / ) Housing Side and Base LED driver O-Ring DHR0 Cable gland Pg 9 Gasket DHR0 Side Side mounting piece Membrane Vent Led platinum dragon PCB - Potting matrial: Polyurethaan Neoprene - shore 0 Body: Polyamide - Seal: Neoprene Neoprene - shore 0 Delrin black Body: Silicone rubber - Membrane: eptfe Number

8 EXPLODED VIEW - RETROFIT Item Part Material Cover Gasket DHR0 Glass Tube Heatsink triangle LED PCB (Starboard / ) (Port / red) (Masthead / Stern / ) (Towing / ) Housing Retrofit (Only Retrofit) LED driver Gasket Retrofit (Only Retrofit) Neoprene - shore 0 Borosilicate glass Seawater resistant aluminium MC-PCB, aluminum. mm Led platinum dragon PCB - Potting matrial: Polyurethaan Neoprene Quantity Number

9 EXPLODED VIEW - HOISTABLE 9 0 Item Part Material Cover Gasket DHR0 Glass Tube Heatsink triangle LED PCB (Starboard / ) (Port / red) (Masthead / Stern / ) (Towing / ) Housing Side and Base LED driver O-Ring DHR0 Base plate hoistable Cable gland Pg 9 Membrane Vent Gasket suspension bracket suspension bracket Neoprene - shore 0 Borosilicate glass Seawater resistant aluminium MC-PCB, aluminum. mm Led platinum dragon PCB - Potting matrial: Polyurethaan Neoprene - shore 0 Body: Polyamide - Seal: Neoprene Body: Silicone rubber - Membrane: eptfe Neoprene - shore 0 Stainless steel 9 0 Quantity 9 Number

10 ELECTRICAL SPECIFICATION Power VDC Output LED DRIVER LEDS Flashing 0 P/min Retrofit + +VDC 0VDC PE - PE Close to Flash LED PCB LED driver Grounding (PE) is not required, but gives better ESD/EMI protection Navigation light Power supply Nomale voltage Typical wattige* Typical current* All types 0mA VDC ma Minimum operating current >0mA Error current Inrush current <0mA 0A * Depends on temperature, LED colour and LED production series LIFETIME CONTROL Measurements of the navigation light and specifications retrieved from the OEM, show a conformity with the minimum requirements of COLREG at an operational lifetime of hrs. To guarantee a proper use of the LED navigation lights, we as a manufacturer advise the following: Ÿ Use the navigation light in combination with a DHR-specified control system, which monitors the status and operational life time of each individual navigation light Ÿ Each navigation light needs to undergo a quality check at least every years of use to verify it still meets the requirements of COLREG 0

11 POSITIONING SIDE LIGHTS Power-driven vessels Paint the inside matt black Paint the inside matt black K Parallel to the keel line Parallel to the keel line K- 9,, J J H H L L Sailing vessels J L H K J J J [mm] L Disclaimer: Ÿ The minimum luminous intensity requirements in the forward direction are only guaranteed if the sidelights are mounted in accordance with this drawing and table. Ÿ This is an illustration to indicate the dimentions of the inboard screens, relative to the keel line of the vessel. By no means may this image be used to determine the position of the sidelights on the vessel. For positioning the lights at the vessel always check for compliance with COLREG or local rules.

12 POSITIONING ALL-ROUND LIGHTS S [mm] D [mm] D S Diagram for choosing the minimum distance between obstacle and mounting plate Disclaimer: This is an illustration to indicate the position of the all-round light so not to be obscured by mast, topmasts or structures within the angular sector of more than degrees. By no means may this image be used to determine the position of the all-round lights on the vessel. For positioning the lights on the vessel always check for compliance with COLREG or local rules.

13 MOUNTING Base mounting M x L L=+P Min. Ø0 Ø P Remarks: Ÿ The mounting plate for navigation lights should be at least mm Ÿ The permissible torque should be, Nm Ÿ Use only A-grade stainless steel fasteners Side mounting M x L M x L L=0+W L=0+W W W Ø 0 Ø, Remarks: Ÿ The permissible torque should be Nm for M and Nm for M Ÿ Use only A-grade stainless steel fasteners All dimensions in mm.

14 ADVANCED MARITIME SIGNALLING SOLUTIONS SIN C E 9 Den Haan Rotterdam Fascinatio Boulevard 909 VA Capelle a/d IJssel T + (0) 0 0 E Sales@dhr.nl

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam TECHNICAL MANUAL DHR80 LED SIN CE 922 Den Haan Rotterdam TABLE OF CONTENTS Disclaimer Technical data Product photos Dimensions Available models Exploded view - base mounting Electrical specification Electrical

More information

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC TECHNICAL MANUAL DHR40 LED MED96/98/EC SINCE 19 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete

More information

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC TECHNICAL MANUAL DHR80 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete

More information

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete

More information

TECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC TECHNICAL MANUAL DHR55N MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete

More information

TECHNICAL MANUAL DHR70N. Den Haan Rotterdam

TECHNICAL MANUAL DHR70N. Den Haan Rotterdam TECHNICAL MANUAL DHR70N SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete or incorrect.

More information

TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam

TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam TECHNICAL MANUAL DHR70N Polar SINCE 1922 Den Haan Rotterdam WARNING! - Turn power off before inspection, installation or removal - Keep combustible materials away from lamp - Allow lamp/fixture to cool

More information

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT Datasheet liniled Handrail 42.4 V1017 F RoHS IP40 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 42.4 Product information Technical specifications Product specifcations Required

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Datasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT

Datasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT Datasheet liniled Handrail 4 V1017 F RoHS IP40/IP65 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 4 Product information Technical specifications Product specifcations Required

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

T-CITY. Waterproof protection for LED lighting

T-CITY. Waterproof protection for LED lighting Waterproof protection for LED lighting The T-CITY series was designed as LED lighting device for CNC machines. Elegant and compact, the T-CITY has just 38 mm diameter, making it suitable to fit small spaces.

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm > Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Base set n

More information

liniled Handrail liniled Handrail Number of LEDs

liniled Handrail liniled Handrail Number of LEDs liniled Handrail liniled Handrail Number of LEDs Light output Beam angle Dimensions Protection Voltage Power Finish Material Warranty Notes 7 per section / 35 per metre (Deco) 7 per section / 35 per metre

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost

More information

Installation and Operating Instructions Bypass Flow Meter DST

Installation and Operating Instructions Bypass Flow Meter DST Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions

More information

a. On the centerline of the T-top b. On the aft starboard corner of the deck c. On the aft deck as close to centerline as possible

a. On the centerline of the T-top b. On the aft starboard corner of the deck c. On the aft deck as close to centerline as possible 1. A 22 fishing boat has separate side lights due to an anchor roller at the bow. Where should the all-round light be positioned for use in international waters? a. On the centerline of the T-top b. On

More information

LED Directionals Helios LED light bars

LED Directionals Helios LED light bars LED Directionals Helios LED light bars Xenon strobe beacons 2012 Catalogue SAFETY AND WARNING LIGHTING Brought to you by a team with long experience in the development, manufacture and sale of flashing

More information

Less power great performances

Less power great performances 148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

RAI-M series RUDDER ANGLE INDICATOR SYSTEM RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr GENERAL Seafirst Rudder

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

SEries 29 Hydrant valves installation, operation & maintenance manual

SEries 29 Hydrant valves installation, operation & maintenance manual Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

GEMS SENSORS & CONTROLS

GEMS SENSORS & CONTROLS GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Floodlight LED Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity

More information

Rule 21 - Definitions

Rule 21 - Definitions (a) "Masthead light" means a white light placed over the fore and aft centreline of the vessel showing an unbroken light over an arc of the horizon of 225 degrees and so fixed as to show the light from

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

Pressure Wave Switches. Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers

Pressure Wave Switches. Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers Pressure Wave Switches Profiles, push buttons, pressure cells and ground sensors for automatic doors, gates and barriers Maintenance free, robust, tried-and-tested Very fast closing Pressure wave technology

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Terminal Head Section User Guide

Terminal Head Section User Guide Example: Terminal Heads Terminal Head Section User Guide Ø100 105 Ø52 Process Conduit Entry Entry KNC 3/4 M20 x 1.5 4.25 5.53 62 34.5 IP6 200 o C Product Photograph 14 Technical Drawing (measurements in

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

FL200 Monochromatic Architectural Spot and Floodlight

FL200 Monochromatic Architectural Spot and Floodlight DATE: TYPE: COMPANY: PROJECT: 360 375mm 14.7in 463mm 18.2in 269mm 10.7in 421mm 16.6in 77mm 3.0in *SM bracket mounting option shown. See page 2 for more mounting options. FEATURES: OPTIONS: Over 16,500

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

Mörth Marine Austria / / Tel.: 0043 (0) Mörth Marine Slovenia

Mörth Marine Austria   / / Tel.: 0043 (0) Mörth Marine Slovenia 136 B* 111177 12,31 B* 111799 12,31 B* 111800 12,31 B* 111801 12,31 Cyclic lights B* 111802 12,31 B* 111803 12,31 B* 111805 12,31 B* 111804 12,31... 111177 111799 111800 111801 Description...Starboard

More information

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments

More information

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions ,, CD, and PD Membrane level indicator for solids Operating Instructions Index Page Safety instructions................................................................................... 02 Operating instructions

More information

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the COLREG

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the COLREG INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the COLREG CONTENTS COLREG1 Interpretation to COLREG 1972 Annex 1, Section 9 (b) Corr.1 Feb 2013 COLREG2 Interpretation to COLREG

More information

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X Erection, maintenance and disposal Inverted installation Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X 1 Important information The following instruction is valid for PEXLIM R-X, PEXLIM

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel The Yacht Group - 4545 Ponce de Leon Blvd. Coral Gables FL 33146 Tel. 305.667.5811 - Fax. 305.663.5551

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical

More information

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

DS MB, MBF THREE PORT VALVES

DS MB, MBF THREE PORT VALVES DS 4.501 04/96, F THREE PORT VALVES Specification No. 617-X-XXX* F 618-X-XXX* and F valves are of the 3-port rotary-shoe type. They are characterised for use as mixing or diverting valves, with hot or

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Pressure switch and Thermostat CAS

Pressure switch and Thermostat CAS Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications

More information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to RV* FH1 G G B FH Specifications Descriptions Cylinder bore size Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke length Rod diameter Capacity of

More information

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating

More information

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp. ASME and PED Requirements for Drum Level Instrumentation 2017 Presented by: Amir Hedayatnia Clark-Reliance Corp. Topics Gage Glasses and Remote Reading Instruments ASME Code Section I Requirements for

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,

More information

CERTIFICATION TEST REPORT

CERTIFICATION TEST REPORT CERTIFICATION TEST REPORT 515 Gus Hipp Blvd. Rockledge, Florida 32955 Telephone (321) 632-2008 http://www.imanna.com Post Office Box 560933 Rockledge, Florida 32956-0933 FAX (321) 690-3360 CERTIFICATION

More information

zkratka označení: PAL* technický list výrobku vytvořeno :13 1/6 pneumatický pohon série RE > tvrdý anodizovaný hliník NBR

zkratka označení: PAL* technický list výrobku vytvořeno :13 1/6 pneumatický pohon série RE > tvrdý anodizovaný hliník NBR pneumatický pohon série RE > tvrdý anodizovaný hliník zkratka označení: PAL* technický list výrobku Ausf Feder Modell Nm Port DW L B H kg RE161 RE1 RE043 RE6 RE161 RE1,1 bei 6 bar 35,5 bei 6 bar 70,6 bei

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

User Manual V14.1 IP68 LED FLEX NEON

User Manual V14.1 IP68 LED FLEX NEON User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating

More information

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications RV* FH1 G B FH G A S Specifications Descriptions Size Cylinder bore size mm Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09 Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL Instruction for use Thank you for selecting an AVK product. With correct use, the product is guaranteed to deliver a long and reliable service. This manual has been prepared to assist you with the installation,

More information

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

FH500 Series. Open and close angle: 20 at open, -5 at closed. FH510-D FH512-D FH516-D FH520-D FH510-O FH512-O FH516-O FH520-O Actuation.

FH500 Series. Open and close angle: 20 at open, -5 at closed. FH510-D FH512-D FH516-D FH520-D FH510-O FH512-O FH516-O FH520-O Actuation. RV* FH G G FH G N/ S/F Specifications Double acting/single acting FH Series Open and close angle: at open, - at closed FH FH-D FH-D FH-D FH-D FH-O FH-O FH-O FH-O Actuation Double acting Single acting Working

More information