1 multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

2 Table of Contents Introduction... Health & Safety Health. Safety. Designs & Dimensions.. Delivery.. Offloading. Payment.... Scope of Supply.. Installation Guide Introduction... General.. Installation. Features Benefits.. Options Available Appendix A: Top Multi - II. Appendix B: Pedrollo NKm Pump.. Appendix C: Pressure Vessels... Appendix D: DG Flow Pressflo Controller Appendix C: DG Flow Steady Press Controller.. Appendix F: Sterilight UV Unit

3 Introduction This Installation, Operation and Maintenance ( O&M ) manual includes descriptive literature, specifications and drawings relating to the principal mechanical and electrical equipment incorporated in the unit. It is the responsibility of the installer and owner to read and fully understand these instructions before installing, commissioning or operating the unit. In the unlikely event of problems occurring with your unit you may either refer to this manual, additional manuals provided with your particular unit or contact your equipment supplier/eps directly. The unit is designed to well proven processes with our engineering expertise to produce high quality system which are robust and reliable. The unit will provide long and trouble free operation providing the simple maintenance procedures laid out in this manual or additional manuals provided with your particular unit are regularly carried out. Your attention is drawn to the Health and Safety section at the beginning of this manual. It is IMPERATIVE that you read these instructions BEFORE working on or using this unit. The unit is designed for a pumped feed, from a mains or private water supply This unit is for drinking water only and is not suitable for pumping chemicals strong acids or alkalis, oil and grease, pesticides or photographic chemicals of any kind If you have any further questions, please contact EPS

4 Health & Safety ( I mportant - Please Read This Before Starting Any Work on the Unit. ) Safety, Health and Welfare at Work Act Section 16.1 ( a ) of this Act requires manufacturers to advise their customers on the safety and the handling precautions to be observed when installing, operating, maintaining and servicing their products. The user s attention is there drawn to the following: 1. The appropriate sections of this manual must be read before working on the equipment. 2. Suitably trained or qualified personnel must carry out installation and servicing. 3. Normal safety precautions must be taken and appropriate procedures observed to avoid accidents. Refer to EPS or your local supplier for technical advice or product information. HEALTH Only potable water is to be connected to your Multi-Boost system. SAFETY As with all site work the dangers of working with water and electricity pose severe threats to health if obvious and fundamental precautions are not taken, therefore, if you are in any doubt with any of the following, please do not hesitate to contact us. All site work should be undertaken by qualified personnel only.

5 Design & Dimensions Dimensions of Standard Multi-Boost 250 Ltr 300 Ltr (Slim-line) 500 Ltr 750 Ltr O/A Diameter (mm) A O/A Height (mm) B Height of inlet from base (mm) C Standard Unit Approx Weight empty (kg)* *Weight shown for standard unit pump and controllers but can vary according to customer requirements. B C A

6 Delivery Offloading The purchaser has overall responsibility for offloading the unit and any accessories. Do not lift the unit if it contains any water. Maintain control over the unit if lifting by use of guide ropes. Do not allow the unit to impact against other objects. If the unit is stored on site prior to installation, it must be upright on a flat and level ground where it cannot be punctured or otherwise damaged. Payment EPS require payment in full for the system prior to delivery, unless other credit terms have been agreed. Scope of Supply EPS will deliver complete Multi-Boost system as ordered.

7 Installation Guide INSTALLATION Step 1 Access & connect 1¼ overflow to waste drain by suitably qualified plumber. Note: As this overflow is gravity operated a minimum fall of 1:50 is recommended. Step 2 Remove inspection hatch / access & fit ( internally ) the black quick stop ball cock to the to the black inlet unit. Note: The quick stop ball cock is supplied loose for transport purposes and should only take a few seconds to fit. Step 3 Only then connect mains water supply externally to the inlet connection using provided ¾ BSP connection. Step 4 Access and connect dwelling pipework to 1 BSP outlet to supply pipe work. Note: This is to be carried out by suitably qualified plumber. Step 5 Turn on mains water and check all connections for leaks. Turn off water again once checked. Note: Ensure electrical power is off/isolated before continuing to next step. Step 6 Connect electrical supply cable ( pre-wired pump control cable ) to a suitability rated fore spur or plug-top with safety earthing connection ( 2 20v 13A single phase ). Note: Wiring of supply cable should only be carried out by a suitably qualified electrician. Electronic control 1 Drain / optional connection to parallel tank Submersible Pump c/w float switch Quick stop ball cock ( s upplied loose ) ¾ BSP inlet

8 Installation Guide INTRODUCTION Though every care has been taken to ensure that your Multi-Boost Water System has arrived complete. Please visually check to ensure that no damage has occurred during transport. GENERAL Before Installation please turn off water at point of entry to property/dwelling and please do not connect electrical supply until advised later in this guide as this could result in an electrical shock. Wiring of supply cable ( pre-wired pump control cable ) should only be carried out by a suitably qualified electrician. Pre-wired pump control cable 1 Outlet to supply pipe work Inspection / Access Hatch Electronic supply cable ¾ BSP inlet connection 1 ¼ BSP overflow connection to waste Before installation begins choose an area with a flat solid concrete base where your Multi-Boost Water System is protected from both frost/ vandalism ( p referably indoors as the unit is not supplied with tamper proof equipment or insulation. We recommend that this area be near to all services as this reduces the need for extra plumbing and electrical requirements. Position the unit so that all connections and the inspection cover is easily accessible. A few minutes of planning will save you time and energy.

9 Installation Guide FEATURES Non-corrosive holding tank Protection lid enclosure as standard Ball cock to control water flow to tank Pressure pump ( fully submerged in water ) Electronic controller - stops and starts pump Dry run protection included 1 drain off valve Connections: Inlet ¾ Outlet 1 Overflow 1 ¼ BENEFITS Ideal if mains pressure is low or inconsistent Good storage capacity in dust/vermin proof container Pump is submerged in water - no problems with leaks or priming Very silent operation Minimal installation requirements Multiple tanks inter-connection option available OPTIONS AVAILABLE Multi-Boost Presflo Multi-Boost Intelli Multi-Boost VSD Multi-Boost UV - Presflo Controller - Intelli Pressure System - Steadypress Variable - 5 Micron Filter - Pedrollo Top Multi Pump - 12 litre Vessel Speed Drive Controller - UV Disinfection System Volume Code 250 ltr ltr ltr Pedrollo Top Multi Pump Volume Code 250 ltr ltr Pedrollo NKm 2/3 pump Volume Code 250 ltr ltr ( 4 5 I/m ) Code ltr ltr

10 Appendix A: TOP Multi - Ⅱ

11

12

13

14 Appendix B: Pedrollo NKm pump

15

16

17

18

19

20 Appendix C: Pressure Vessel

21

22 Appendix D: DG Flow Pressflo Controller

23

24 Appendix E: DG Flow Steady Press Controller

25

26 Appendix F: Sterlight UV Unit

27

28 let us make your environment a better place to be demand special treatment Borehole Pumps Multi-Boost Water Pumps Filter Housing For product enquiries, specification advice, project assessments or further information, please contact the EPS team on: Booster Sets UV Disinfection info@epswater.ie Mallow, Co. Cork Ballyhaunis, Co.. Mayo Pressure Vessels Tel: Fax: Tel: Fax: Filtration Mountrath, Co. Laois Tel: Naas, Co. Kildare Tel: Fax: Sewerage Pumps Water Softeners

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Airfix D-E-B Installation and operating instructions

Airfix D-E-B Installation and operating instructions www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel

More information

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation

More information

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal 2 C Lite CAD SERIES Patented CAD-2 diaphragm technology Unique 3 piece construction Reinforced Plastic Connection Durable continuous strand fiberglass sealed with epoxy resin NSF Standard 61, CE/PED, WRAS,

More information

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007 Operation and Maintenance manual Document Title: Purewater CWST O&M Issue No: 1 Issue Date: 4th September 2007 This manual is to be used in conjunction with the following products manufactured by Purewater

More information

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats FLOMAX-SYSTEM DOC532/11 Installation, Operating, Maintenance and Safety Instructions for FLOMAX-SYSTEM Pressurised water systems for boats CW343A FloMax System 12 volt d.c. CW344A FloMax System 24 volt

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Micro-S / Micro-S Digital Wall Hung Unit Please fulfil all listed requirements prior to and during

More information

New AQF Filter Polymer Filtration System

New AQF Filter Polymer Filtration System New AQF Filter Polymer Filtration System Operator Manual Covering Serial Number 20002001 onwards February 2011 Index Disclaimer notice...3 Introduction...4 Important safety notices...5 Getting started...6

More information

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE

More information

03/07/2014 V

03/07/2014 V 03/07/2014 V1-03072014 General safety This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge

More information

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats MAXI-SYSTEM DOC50/ Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats CW CW Maxi-System.9+ volt d.c. Maxi-System.9+ volt d.c. CW99A Maxi-System

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by POOL BACKWASH SYSTEM Installation manual Proudly manufactured by Content 1. 2. 3. 4. 4.1 4.2 4.3 4.4 4.5 5. 5.1 5.2 5.3 Backwashing your pool Background Description ecogator component description (bill

More information

In Vessel Composter Installation & Commissioning Manual

In Vessel Composter Installation & Commissioning Manual In Vessel Composter Installation & Commissioning Manual Contents Customer responsibilities Transportation Lifting Delivery Pre-installation requirements Installation Drainage Ventilation Levelling Unpacking

More information

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual Topline Electronics Limited 2105 This publication may not be copied, in full or in part, without prior written consent

More information

Duplex Commercial Softeners

Duplex Commercial Softeners Duplex Commercial Softeners Installation, Operation & Maintenance Guide Manual 003.1 Contents Page 1. Unpacking Instructions 3 2. Installation 4 Pre-installation checks Fitting the bottom distribution

More information

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Dri-Line Mk3 Monnier Compressed Air Drain Trap 5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation

More information

DECLARATION OF INCORPORATION

DECLARATION OF INCORPORATION AESSEAL (MCK) Ltd. Systems Division 139a Hillsborough Old Road Lisburn Northern Ireland BT27 5QE Tel +44 (0) 2892 669966 Fax +44 (0) 2892 669977 When selecting and installing suitable Barrier Fluid System

More information

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall

More information

building the future Rainwater Harvesting System Installation and Operation Manual MDPE Systems PVC-UE Roofline, Window & Cladding Systems

building the future Rainwater Harvesting System Installation and Operation Manual MDPE Systems PVC-UE Roofline, Window & Cladding Systems Rainwater Harvesting System Installation and Operation Manual PVC-UE Roofline, Window & Cladding Systems Rainwater Systems Soil & Waste Systems Underground Drainage Systems MDPE Systems Hot & Cold Plumbing

More information

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2015. All rights reserved. No part of this publication may be reproduced by

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160

More information

The ultimate in water softening

The ultimate in water softening Calming troubled waters Metered Water Softener Specification MODEL: CALSOFT M The ultimate in water softening Due to Calmag s commitment to new product development the photographs contained within these

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pretreatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

OPERATION AND MAINTENANCE

OPERATION AND MAINTENANCE Chapter 11 OPERATION AND MAINTENANCE General Considerations The nature and scope of the operation and maintenance required will vary with the design and elements of water-supply systems. Depending upon

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Water Hygiene Chlorination Water Treatment Legionella Control

Water Hygiene Chlorination Water Treatment Legionella Control www.whs-ltd.com Water Hygiene Chlorination Water Treatment Legionella Control WATER STORAGE TANK DISINFECTION Cleaning and Chlorination Procedure A clean and chlorination has recently been carried out

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

6800 Maintenance Instruction System Flush Procedure

6800 Maintenance Instruction System Flush Procedure Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves

More information

Quantum Contract Pressurisation Unit Operation & Maintenance Manual. Model: QC-35

Quantum Contract Pressurisation Unit Operation & Maintenance Manual. Model: QC-35 Quantum Contract Pressurisation Unit Operation & Maintenance Manual Model: QC-35 1: nstallation Location The following should be considered when choosing the position of the pump set: The area should be

More information

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

Product Range. High performance and economic high pressure solutions Made in Germany

Product Range.  High performance and economic high pressure solutions Made in Germany Product Range Purification Storage Filling Panels Nitrox/Trimix High performance and economic high pressure solutions Made in Germany www.lw-compressors.com 2 Lenhardt & Wagner Solid Growth Lenhardt &

More information

Vertex VP Operation and Maintenance

Vertex VP Operation and Maintenance AIRBENCH LTD Vertex VP Operation and Maintenance This Edition: 2 October 2018 AirBench Ltd, 14 Grange Farm Road, Colchester CO2 8JW www.airbench.com +44 (0) 1206 791191 Copyright AirBench Ltd 2016 Page

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information Read this manual carefully

More information

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG PUNE TECHTROL PVT LTD Instruction and Maintenance Manual for and Tape Gauge FTG INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FLOAT AND TAPE GAUGE FTG 1 Introduction : It is used to measure and indicate

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS WASTE WATER Solutions ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS Reliable and well-proven inlet screen for municipal sewage treatment plants and industrial wastewater and process water screening with

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

O&M Receiving and Inspection. Storage of Water Treatment Media

O&M Receiving and Inspection. Storage of Water Treatment Media O&M 105.1 Receiving and Inspection 1. Equipment should be checked against the Bill of Lading to verify that the number of pieces received matches those shipped. 2. Equipment should be carefully inspected

More information

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR WASTE WATER Solutions HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR Reliable and well-proven inlet screen for municipal sewage treatment plants and industrial wastewater and process water screening

More information

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Please read these instructions before assembling your BioSieve * This unit is heavy and should be moved by two people * To remove the BioSieve from its box, lay the box on its

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

Operating instruction

Operating instruction Operating instruction MV, XV, HG, HP, RKO, D2G, TV, BV, WB & SLV 1 Introduction 2 2 Stafsjö s knife gate valves 2 3 Technical information 2 3.1 Pressure test 2 3.2 Labelling 2 4 Storage 3 5 Transportation

More information

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering Manual Bypass Feeder Chemical Addition and Filtering Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 918-686-6211 Fax: 918-686-6212 www.advantagecontrols.com

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools Feeder specifications hth EASIFLO To ensure you know which feeder is best suited for your swimming pool, our dedicated team of technical account managers will recommend the correct feeder is specified.

More information

SPA WORLD. Pre- delivery Guide

SPA WORLD. Pre- delivery Guide SPA WORLD Pre- delivery Guide HELLO! This document is designed to provide all the information you need to ensure the smooth delivery and installation of your spa or swim spa. Please read it carefully and

More information

Potable Water Truck Safe Work Procedure PTES_HSE_SWP_041. Name Date Signature. Author Geoff Selfe 25/01/2016. Reviewed Solomon Site 25/01/

Potable Water Truck Safe Work Procedure PTES_HSE_SWP_041. Name Date Signature. Author Geoff Selfe 25/01/2016. Reviewed Solomon Site 25/01/ Potable Water Truck Safe Work Procedure PTES_HSE_SWP_041 Name Date Signature Author Geoff Selfe 25/01/2016 Reviewed Solomon Site 25/01/2016 ----- Approved Michael Garkaklis 25/01/2016 Key Safety Acts Complete

More information

80 Litre Suction Oil Drainer

80 Litre Suction Oil Drainer 80 Litre Suction Oil Drainer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity

More information

Residential Pressure Booster Systems

Residential Pressure Booster Systems Residential Pressure Booster Systems HOW IT WORKS When the pressure available is insuffi cient it is necessary to install a boosting system. FLUX BOOSTING SYSTEM starts and stops according to the user

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice

More information

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1 Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

You are now the proud new owner of an Alpine Swim Spa!

You are now the proud new owner of an Alpine Swim Spa! Congratulations! You are now the proud new owner of an Alpine Swim Spa! Your Swim Spa will soon be ready and waiting for the whole family to enjoy. This Pre-Delivery guide is designed to ensure that the

More information

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL PRODUCT CATALOGUE State of the Art * Electronic starters * Inverters * Protection devices For * Stable Pressure Control * Dry Run Protection * Energy Saving * Water Saving YOURWATER UNDER CONTROL DPI Trading

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

JET Mini Mechanical Pressurisation Equipment

JET Mini Mechanical Pressurisation Equipment JET Mini Mechanical Pressurisation Equipment Mini Models (130HL, 230HL) Operation & Maintenance Manual Rev 2.2 We reserve the right to change designs and technical specifications of our products. Rev 2.2

More information

FV Flash Vessel Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions 4041050/5 IM-P404-10 EMM Issue 5 FV Flash Vessel Installation and Maintenance Instructions 1. Safety information 2. Specific product safety information 3. Product information 4. Installation 5. Commissioning

More information

Summary of the MRA LPG Codes of Practice

Summary of the MRA LPG Codes of Practice Summary of the MRA LPG Codes of Practice COP A1 DESIGN and INSTALLATION Code COP A1 deals with above ground installations where LPG is stored under pressure at ambient temperatures in fixed vessels larger

More information

Swimming Pool Winterizing

Swimming Pool Winterizing Swimming Pool Winterizing 1. Remove Solar Cover During the closed season, when the pool is not in use, a solar cover must be cleaned and hosed down with fresh tap water, folded or rolled, and stored in

More information

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap 0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and

More information

PRESSURISED PAINT CONTAINER

PRESSURISED PAINT CONTAINER PRESSURISED PAINT CONTAINER MODEL NO: CPP2B PART NO: 3082115 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE Pressurised Paint Container. Before attempting

More information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall

More information

Technical Service Bulletin March 2015 TSB142.01

Technical Service Bulletin March 2015 TSB142.01 Technical Service Bulletin March 2015 TSB142.01 Commissioning Procedure for HYDRAcap This Technical Service Bulletin provides information for commissioning of a HYDRAcap membrane system in a water treatment

More information

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry Article Takeaways: Chris Doerschlag President ALB Klein Technology Group www.albkleinco.com 1. Troubleshooting Guide

More information

OPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E

OPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E OPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E P O BOX 5413, JOHANNESBURG 2000 TEL: (011) 493-8209 FAX: (011) 493-1459 E.MAIL : info@adceng.co.za P O BOX 37208, CHEMPET

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

ENERGY BLADE 3K4. Energy Blade Installation Instructions

ENERGY BLADE 3K4. Energy Blade Installation Instructions ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and

More information

Flamco Flamco-Fill STA Flamco-Fill STM

Flamco Flamco-Fill STA Flamco-Fill STM STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744

More information

CUT OFF TOOL MODEL: CAT113

CUT OFF TOOL MODEL: CAT113 CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you

More information

User's Manual. MixRite TF 10. Edition 05.08

User's Manual. MixRite TF 10. Edition 05.08 User's Manual MixRite TF 10 Edition 05.08 1 Tefen MixRite TF 10 fertilizer and chemicals Injector Congratulations on your purchase of one of Tefen s high quality products. To get the best results from

More information

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER Installation, Operating & Maintenance Instructions EW1050 I00232_Mar 2016 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER INSTALLATION

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

Safety instructions and operating manual

Safety instructions and operating manual 5-Master Safety instructions and operating manual TBF-PyroTec GmbH Lichterfelder Str. 5 A 21502 Geesthacht Tel.: + 49 (0)4152 157 9950 Fax: + 49 (0)4152 157 9951 Flame projector 5-Master Safety instructions

More information

Compact Transfer Pump

Compact Transfer Pump Munster Simms Engineering, better known under the product brand name Whale, is an independent company engaged in the design, manufacture, marketing and selling of pumps, valves, faucets and plumbing (water

More information

VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)

VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V) VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V) UCY series, CY series, CE/V series, OP series Conical vortex regulator Type WAB-UCY (wet installation) Vertical vortex regulator Type WAB- CE/V (wet installation)

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Reverse Osmosis System Installation Guide and Operation Manual.

Reverse Osmosis System Installation Guide and Operation Manual. Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Skum Bladder Tank Type Vertical. Table of Contents Page General Description 2 1. Installation 1.1 Safety 2 1.2 Transporting 2 1.3 Inspection 2 1.4 Filling Instruction 3-7

More information

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors 0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

Chapter 10 SWIMMING POOLS

Chapter 10 SWIMMING POOLS 4-10-1: COMPLIANCE REQUIRED: Chapter 10 SWIMMING POOLS It shall be unlawful to construct, maintain, install or enlarge any swimming pool in the City except in compliance with the provisions of this Chapter.

More information

FLOWMETERING STORAGE TANKS FROM THE INSIDE

FLOWMETERING STORAGE TANKS FROM THE INSIDE FLOWMETERING STORAGE TANKS FROM THE INSIDE Peter Duzevich 1, David Barry 2 1 Commercial Diver, Ass. Project Manager, Rope Access Technician 4 Helsal Crt. Coomera, QLD 4209 Ph: (07)55019505 Fax: (07)55019506

More information

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance

More information