ProMinent Price List. Gas Chlorination. ProMinent Fluid Controls Pty Ltd
|
|
- Cecily Garrison
- 6 years ago
- Views:
Transcription
1 28 Price List ProMinent Fluid Controls Pty Ltd Gas Chlorination Head Office: Unit 4, 4 Narabang Way BELROSE NSW 285 AUSTRALIA (PO Box 85, BELROSE WEST NSW 285) Phone: (2) Fax: (2) sales@prominentfluid.com.au Web: Brisbane Office: Beaudesert Road COOPERS PLAINS QLD 418 Phone: (7) Fax: (7) pfcqld@prominentfluid.com.au Melbourne Office: Unit 2, 88 Star Crescent HALLAM VIC 383 Phone: (3) Fax (3) pfcvic@prominentfluid.com.au We reserve the right to make pricing and technical changes. This PriceList supersedes all previous price lists. E. & O. E. All prices subject to the addition of GST. Sydney, 1st January 28 ProMinent
2 Revised: 1st January 28 ProMinent Chlorination Systems ProMinent offer Hydro Vacuum operated gas chlorinators with capacities available from a maximum of 75 gm/h through to a maximum 4 kg/h. Chlorinators are suitable for direct bottle or drum mounting or alternatively for header mounting. With header mounting systems, we offer our horizontal and vertical headers complete with heating, flexible connections and auxiliary cylinder or drum valves. Wherever possible, we recommend direct cylinder mounting to eliminate pressure lines and the costly replacement of flexibles and cylinder valves. Hydro body parts are machined from a solid block of PVC and are not injection moulded. Machining is more expensive, but eliminates the residual stresses from the moulding process that lead to cracking and warping. Hydro chlorinators therefore have thicker and more rigid walls and the bodies will not warp. The main diaphragm is double O-ring sealed. The rate valve is solid silver an alternative is PVDF. The Hydro inlet valve assembly is easy to dismantle and clean without special tools. Hydro use a yoke assembly for mounting the chlorinator which provides positive sealing. The ejector check valve has a self-centring seal and provides positive shut-off. Hydro s simple construction permits an operator to repair or replace parts, in most cases with only the need for a screwdriver. Spare parts are readily available and are not overpriced. In many cases it may be cheaper to buy a new Hydro chlorinator than to repair another brand. Systems available with Hydro chlorinators include remote ejectors, remote rate control valves, automatic changeover units and 4-2 ma servo control systems. Other accessories such as chlorine gas leak detectors and complete installation of systems are available. Please do not hesitate to contact one of our offices, should you require pricing or further details on this range of equipment.
3 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST 9 Series with ejector, remote meter & accessories Max. Capacity Part No: List Price Cylinder, Wall or Header Mounting - 9 series up to 2kg/hr systems (Note: header, heater, auxilary valves & flexibles extra) 75 g/h 1 x Vacuum Regulator, Remote Meter & Ejector 92C $ 2,48 2 g/h 1 x Vacuum Regulator, Remote Meter & Ejector 921C $ 2,48 5 g/h 1 x Vacuum Regulator, Remote Meter & Ejector 922C $ 2,48 1 g/h 1 x Vacuum Regulator, Remote Meter & Ejector 923C $ 2,48 2 g/h 1 x Vacuum Regulator, Remote Meter & Ejector 924C $ 2,48 Up to 4Kg/Hr Systems 1 x Vacuum Regulator, Remote Meter & Ejector 98C $ 2,674 Up to 1Kg/Hr Systems 1 x Vacuum Regulator, Remote Meter & Ejector 99C $ 3,19 Rotameter Rotameter Heater Water Supply Ejector Chlorine Solution Water Supply Ejector Chlorine Solution In-Built Auto Changeover System (max 2 Vacuum Regulators) - 9 series up to 2kg/hr systems (Note: header, heater, auxilary valves & flexibles extra) 75 g/h 2 x Vacuum Regulator, Remote Meter & Ejector 935C $ 3,738 2 g/h 2 x Vacuum Regulator, Remote Meter & Ejector 945C $ 3,738 5 g/h 2 x Vacuum Regulator, Remote Meter & Ejector 955C $ 3,738 1 g/h 2 x Vacuum Regulator, Remote Meter & Ejector 965C $ 3,738 2 g/h 2 x Vacuum Regulator, Remote Meter & Ejector 975C $ 3,738 Up to 4Kg/Hr Systems 2 x Vacuum Regulator, Remote Meter & Ejector 985C $ 4,26 Up to 1Kg/Hr Systems 2 x Vacuum Regulator, Remote Meter & Ejector 995C $ 4,457 Rotameter Flexible Rotameter Auxilary Cyl. Valve Heater Heater Water Supply Ejector Chlorine Solution Water Supply Ejector Chlorine Solution
4 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST 9 Series with ejector, remote meter & accessories Max. Capacity Part No: List Price TON Mounting - 9 series up to 2kg/hr systems 75g/h 1 x Vacuum Regulator, Remote Meter & Ejector 925C $ 3,999 2g/h 1 x Vacuum Regulator, Remote Meter & Ejector 926C $ 3,999 5g/h 1 x Vacuum Regulator, Remote Meter & Ejector 927C $ 3,999 1g/h 1 x Vacuum Regulator, Remote Meter & Ejector 928C $ 3,999 2g/h 1 x Vacuum Regulator, Remote Meter & Ejector 929C $ 3,999 up to 4kg/hr systems 4kg/h 1 x Vacuum Regulator, Remote Meter & Ejector 981C $ 4,241 up to 1kg/hr systems 1kg/h 1 x Vacuum Regulator, Remote Meter & Ejector 991C $ 4,673 Rotameter Heater Water Supply Ejector Chlorine Solution In-Built Auto Changeover System (max 2 Vacuum Regulators) - 9 series up to 2kg/hr systems In-Built Auto Changeover System (1 drum per side) 75g/h 2 x Vacuum Regulator, Remote Meter & Ejector 936C $ 6,47 2g/h 2 x Vacuum Regulator, Remote Meter & Ejector 946C $ 6,47 5g/h 2 x Vacuum Regulator, Remote Meter & Ejector 956C $ 6,47 1g/h 2 x Vacuum Regulator, Remote Meter & Ejector 966C $ 6,47 2g/h 2 x Vacuum Regulator, Remote Meter & Ejector 976C $ 6,47 In-Built Auto Changeover System (1 drum per side) 4kg/h 2 x Vacuum Regulator, Remote Meter & Ejector 986C $ 6,829 In-Built Auto Changeover System (1 drum per side) 1kg/h 2 x Vacuum Regulator, Remote Meter & Ejector 996C $ 7,368 Rotameter Water Supply Heater Ejector Heater Chlorine Solution Note: All Ton mounting regulators, vertical & horizontal headers are fitted with 24V heaters. We suggest connection via a Residual Current Device (RCD) safety switch. As an option 24v heaters can be supplied with 24V/24V transformers in enclosure at an extra cost, (will handle two heaters). PA55246 $ 292
5 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST 9 Series with ejector, remote meter & accessories Max. PFC List Capacity Part No: Price TON Mounting - 9 series up to 2kg/hr systems Auto Changeover System (2 drum per side) 976C-2X2 2g/h 4 x Vacuum Regulator, 1 x Remote Meter, 1 x Auto Changeover & 1 x Ejector $ 13,2 up to 4kg/hr systems Auto Changeover System (2 drum per side) 986C-2X2 4kg/h 4 x Vacuum Regulator, 1 x Remote Meter, 1 x Auto Changeover & 1 x Ejector $ 13,578 up to 1kg/hr systems (2 drum per side) Auto Changeover System 996C-2X2 1kg/h 4 x Vacuum Regulator, 1 x Remote Meter, 1 x Auto Changeover & 1 x Ejector $ 14,256 Auto Changeover Rotameter Heater Heater Heater Heater Water Supply Ejector Chlorine Solution Note: For systems using more than 2 drums a side add the cost of extra vacuum regulators required. Note: If more than 1kg required use 2/4 kg Rotameter, Auto Changeover, Ejector or see High Capacity systems. Note: Multiple 9 series vacuum regulators can be drum mounted, however when more than 1kg/hr is required there may be unequal draw down thus leaving some Cl 2 in a drum at time of closedown. In this case use either; a) Header mounted vacuum regulator or b) Sequential change over. (see Sydney office for this). Note: All Ton mounting regulators, vertical & horizontal headers are fitted with 24V heaters. We suggest connection via a Residual Current Device (RCD) safety switch. As an option 24v heaters can be supplied with 24V/24V transformers in enclosure at an extra cost, (will handle two heaters). PA55246 $ 292
6 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST 9 Series Equipment Components Max. PFC List Capacity Part No: Price Bottle, Vertical Wall or Horizontal Header Mount - 9 series up to 2kg/hr systems Vacuum regulator SVR-1-CL2 $ 1,77 Ejector EJO-1-CL2 $ 71 Remote meter MPH-1-CL2 $ 692 Change Over Valve SO1 $ 89 up to 4kg/hr systems Vacuum regulator SVR-25-CL2 $ 1,77 Ejector EJO-25-CL2 $ 881 Remote meter MPH-25-CL2 $ 755 Change Over Valve SO2 $ 89 up to 1kg/hr systems Vacuum regulator SVR-5-CL2 $ 1,761 Ejector EJO-5-CL2 $ 944 Remote meter MPH-5-CL2 $ 1,69 Change Over Valve SO5 $ 89 TON Mount - 9 series up to 2kg/hr systems Vacuum regulator SVR-1T-CL2 $ 2,66 Ejector EJO-1-CL2 $ 71 Remote meter MPH-1-CL2 $ 692 Change Over Valve SO1 $ 89 up to 4kg/hr systems Vacuum regulator SVR-25T-CL2 $ 2,66 Ejector EJO-25-CL2 $ 881 Remote meter MPH-25-CL2 $ 755 Change Over Valve SO2 $ 89 up to 1kg/hr systems Vacuum regulator SVR-5T-CL2 $ 2,66 Ejector EJO-5-CL2 $ 944 Remote meter MPH-5-CL2 $ 1,69 Change Over Valve SO5 $ Vacuum Regulator VRH-2-CL2
7 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST 2kg & 4 Kg High Capacity Chlorination Max. PFC List Capacity Part No: Price NOTE: For up to 15 kg/hr 9 series vacuum regulators can be used. Components only Manifold Mount High Capacity Vacuum Regulator up to 4 kg Vacuum Regulator, No meter & No ejector. VRH-2-CL2 $ 5,392 Ejectors 2 kg High Capacity 2 Flanged Ejector. EJH-1-CL2 $ 4,471 4 kg High Capacity 2 Flanged Ejector. EJH-2-CL2 $ 4,471 Remote Meters 2 kg including flow tube and rate valve. RMH-1-CL2 $ 2,876 4 kg including flow tube and rate valve. RMH-2-CL2 $ 2,876 Switchover Modules 2 kg. SOH-2-CL2 $ 3,61 4 kg. SOH-4-CL2 $ 3,61 Note: header, heater, auxilary valves & flexibles extra see prices for this or complete header (manifold). Auxilary Cyl. Valve Auto Changeover Flexible Rotameter Heater Water Supply Ejector Chlorine Solution Note: All Ton mounting regulators, vertical & horizontal headers are fitted with 24V heaters. We suggest connection via a Residual Current Device (RCD) safety switch. As an option 24v heaters can be supplied with 24V/24V transformers in enclosure at an extra cost, (will handle two heaters). PA55246 $ 292
8 Revised: 1st January 28 hydro Flow proportioning C77 Gas Chlorination Systems 9 Series Each System includes a standard chlorinator unit (complete with rate valves and ejector), an Omni-Valve (automatic flow control valve) complete with standard fitting kit. The Omni-Valve and remote meter are fitted on a backboard pre-piped ready to mount on the wall. Max. Regulator Mounting Method PFC List Capacity Part No: Price 2 kg/hr Cyl. or wall mounting (.2,.5, 1 or 2 kg/hr capacity) PA24-FP92 (92C+OV-11) $ 7,425 one 9 series vacuum regulator 2 kg/hr Cyl. or wall mounting & in-built auto changeover PA24-FP965 (965C+OV-11) $ 8,784 two 9 series vacuum regulators 4 kg/hr Wall or Manifold mounting PA24-FP98 (98C+OV-11) $ 7,576 one 9 series vacuum regulator 4 kg/hr Wall mounting & in-built auto changeover. PA24-FP985 (985C+OV-11) $ 1,114 two 9 series vacuum regulators 4 kg/hr Ton mounting PA24-FPT981 (981C+OV-11) $ 9,143 one 9 series vacuum regulator 4 kg/hr Ton mounting & in-built auto changeover. PA24-FPT986 (986C+OV-11) $ 11,731 two 9 series vacuum regulators 1 kg/hr Ton mounting (1 kg/hr capacity) PA24-FP991 (991C+OV-11) $ 9,574 one 9 series vacuum regulator 1 kg/hr Ton mounting & in-built auto changeover. PA24-FP996 (996C+OV-11) $ 12,27 two 9 series vacuum regulators OMNI-VALVE FOR AUTOMATIC FEED OF CHLORINE GAS Linear drive design eliminates rotary motion - means minimal wear. Max Capacity: 4kg per hr. 2 line x 2 character display. Control Modes: Manual, Flow Pacing, Proportional, Residual, ORP, Compound Loop (PID) and Step-Feed. Contact alarm output and offers standard 4-2 ma output. Ten point linearization process for accurate control. Includes delays, filters and threshold adjustment. OMNI-VALVE SELECTION CHART g/hr Part No: 2 OV-11-1-C $ 4,452 5 OV-11-1-C $ 4,452 1 OV-11-1-C $ 4,452 2 OV-11-1-C $ 4,452 kg/hr Part No: 5 OV-11-1-C $ 4,452 1 OV-11-1-C $ 4,452 2 OV-11-1-C $ 5,29 4 OV-11-1-C $ 5,29
9 Revised: 1st January 28 ProMinent ProGuard series 3 Chlorinator Shut Off Control Package for Drums or Cylinders (Bottles) Part A Wall mounted Master control cabinet for activation of one or multiple pneumatic auto valve close ratchets. Power required, 24 volt. Bottled air or nitrogen required plus regulator. Features, Fail safe pneumatic operation with low pressure alarm. 24 volt operation with over 8 hours battery back-up. Operates from alarm contact on chlorine leak detector, (Separate supply). For up to 4 cyl/drums Part A PA $ 3,636 For more than 4 cyl/drums Part A PA $ 4,761 Part B Bottle Mounting 1 x Pneumatic cylinder and ratchet assembly with special bracket for mounting on each vacuum regulator. Part B PA $ 43 TON Mounting 1 x Pneumatic cylinder and ratchet assembly with special bracket for mounting on each vacuum regulator. Part B PA $ 43 Pressure Header 1 x Pneumatic cylinder and ratchet assembly with special bracket for mounting on each auxiliary valve. Part B PA $ 43 Extras: auxiliary valve Part No: IVH-1-5 (Price on page 11), plus copper flexibles with 3/4 unions (Price and P/N on page 11), or complete horizontal or vertical header if required (Price and P/N on page 11). Quantity required: For one drum or cylinder add 1 x Part A + 1 x Part B For up to 8 drums, cylinders or header add 1 x Part A + Part B x number of drums or cylinders required. Note: Vacuum systems Both Part B above, Bottle & Ton, are suitable for Hydro 9 series Vacuum Regulators. (For retro fitting to Hydro 5, 2 and 7 series consult Sydney office). Air or Nitrogen Regulator available from BOC Gasses approx $156 ORICA Both Hydro bottle mount and Ton mount vacuum regulators can be fitted with an extension arm to allow fitting of ORICA auto valve closing. Extra Price per Cylinder $ 249 Extra Price per Ton mount $ 249 Note: the above will also fit Acromet and W & T (with appropriate adaptor) $ POA Chlorine Leak Detector Gas Chlorination Accessories Chlorine Leak Detector, with single Digital Sensor & Battery Back-up. GA $ 3,376 Chlorine Leak Detector, with dual Digital Sensors & Battery Back-up. GA $ 4, mA Output Note: Outputs for each sensor (up to 4) for one price only GA-17-1-X $ 258 Remote Acknowledge $ 215 Replacement Sensor Element only -1 ppm GA-SEO-CL2-1 $ 699 Replacement Sensor -1 ppm GA-CRS-CL2-1 $ 1,183 Features Up to 4 Digital Sensors User friendly key pad interface for easy calibration and operation. Up to 1 contact relays available. Backlit Liquid Crystal Display (LCD) for easy reading, 2 line, 16 spaces. Built-in 9 db audible alarm and danger/warning LED s 24 Hour Battery Back-Up included RS232 Output Option 4-2 ma Output Option Remote Acknowledge Option Password Protection
10 1 Revised: 1st January 28 hydro Gas Chlorinator Accessories Part No: List Price Bottle & Drum Scales Single Bottle Scale & Control Unit (Digital) with alarm (Note:1) PA $ 2,819 nett Single Bottle Scale & Control Unit (Digital) with alarm & retransmit 4-2mA signal (Note: 2) PA242453A $ 3,82 nett Twin Bottle Scale & Control Unit (Digital) with alarm (Note: 1) PA $ 3,688 nett Twin Bottle Scale & Control Unit (Digital) with alarm & retransmit 4-2mA signal (Note: 2) PA242454A $ 3,948 nett Single Drum Scale & Control Unit (Digital) with alarm & retransmit 4-2mA signal (Note: 2) PA $ 4,399 nett Twin Drum Scale & Control Unit (Digital) with alarm & retransmit 4-2mA signal (Note: 2) PA $ 6,984 nett Trolley & Single Drum Scale & Control Unit (Digital) with alarm & retransmit 4-2mA signal (Note: 2) P.O.A. Trolley only for Single Drum P.O.A. Note: 1. The above Bottle & Drum Scales each have one (1) Control Unit (Digital) with one (1) single point alarm. 2. The above Bottle & Drum Scales each have one (1) Control Unit (Digital) with one (1) single point alarm, and one (1) retransmit 4-2 ma signal. The alarm (and 4-2mA option) signal is from the bottle or drum selected on the control unit. For other options contact Sydney Office. Safety Chains Safety Chains & Brackets single bottle PA $ 78 nett Safety Chains & Brackets dual bottles PA $ 99 nett Twin Bottle Scale & Control Unit Twin Scale & Control Unit
11 Revised: 1st January hydro Gas Chlorinator Accessories Part No: Pressure Connections: Auxiliary Cylinder Valve, 3/4 inlet and outlet. IVH-1-5 $ 354 Flexible Connection cad. plated anealed copper with 3/4" unions, (W & T type drum connection). 1.8m length... TON A24217 $ m length... Bottle A $ 97 Superior Chlorine Valve, for horizontal header mounting B1 $ 269 Flexible Connection 1. m long nickel plated anealed copper. 5/8" UNF male ends. (W & T Spare) A $ 74 List Price Vertical Headers: Vertical Wall Header, painted steel c/w drip leg with 3/4 flat face connections NB: top connection for optional presure gauge, suitable for: 1 x Cylinder A $ x Cylinder PA $ x Cylinder PA $ 313 Adaptor 3/4 BSPP male to 5/8 UNF male, plated brass. A $ 59 Horizontal Header: Each header (manifold) comes complete with header valve for vacuum regulator, drip leg & heater, and for EACH connection 1 x header valve, 1 x auxillary valve & 1 x flexible connection. 2 x drums HM-122 $ 2,358 3 x drums HM-123 $ 3,86 4 x drums HM-124 $ 3,813 Chlorine Manifold Y-Strainer (weight 7 kg) Carbon Steel Body, Monel Screen, Lead Gasket Sealed Cover RH-6786 $ 1,167 Chlorine Manifold Filter (weight 2 kg) 25, lb. tensile strength grey iron casting rated at 56 psi (38 bar), and comes with removeable filter cartridge. Acts as a filter and condensate trap. C-282 $ 2,554 Heater for header mounting, 24V AC, 3W NB: Use RCD Safety Switch A $ 176 Optional heater for header mounting, 24V AC, 25W c/w 24v transformer PA $ 388 Note: for second 24v heater add $ 189 (max. 2 heaters per transformer). For extra ton units Power Supply: 2 x 24V6Va 24V Supply PA55246 $ 191 Heater for ton mounting drip leg, 24V AC, 25W, (75 x 5 pad) 84A24V $ 19 Universal TON mounting Drip Leg c/w heater PA-TUY-1 $ 895 Injection Systems: Withdrawable * PVC Injection lance, with 2mm hose tail, inc. SS valve & nipple PA $ 171 Withdrawable * PVC injection lance, with 25mm hose tail, inc. SS valve & nipple PA $ 171 * Note: Suitable for maximum of 2 kg/h chlorine. Non Withdrawable PVC Injection/Diffuser tube c/w 1" BSPF PVC valve & 25mm Hose Tail. Note: Suitable for maximum of 2 kg/h chlorine. PA $ 121 Non Withdrawable PVC Injection/Diffuser tube c/w 1 1/2" BSPF PVC valve & 4mm Hose Tail. Note: Suitable for maximum of 1 kg/h chlorine. PA $ 269 Flexible Tubing: E.V.A. Chlorine vacuum tubing 12 x 8mm. A $ 3 /metre E.V.A. Chlorine vacuum tubing 17 x 12mm. A $ 6 /metre Indicators Auto vacuum change over Left/Right cylinder bank indicator, PA $ 1,214 mounted in 175 x 125 PVC enclosure. Note: Requires auto changeover valve or extra remote meter High/Low vacuum indicator fitted to remote meter, PA $ 1,214 mounted in 175 x 125 PVC enclosure. Note: Requires remote meter Note: if both PA24218 and 219 are used together total price can be reduced by $435 Special lubricant for O-Rings MOLYKOTE 1gm tube FS 3452 $ 98 Twisted Spanner $ 36
12 12 Revised: 1st January 28 hydro Gas Chlorinator Accessories Horizontal Manifolds with 1214-B1 Chlorine Valves IVH-1-5 Auxillary Cylinder Valve 1214-B1 Chlorine Valve for Horizontal Header PA-TUY-1 Universal Ton Drip Leg Vertical Header Filter C-282 A Adaptor for use with 1.8m A24217 & 1.m A Flexible connections Adaptors 15mm PVC Solvent Weld to 12 x 8 Tube 15mm PVC Solvent Weld to 17 x 12 Tube 15mm PVC Solvent Weld to 1/2 NPT PA PA2411 PA HTS-1 Twisted Spanner 1/4 NPT O-Ring to 12 x 8 Tube PA /8 NPT O-Ring to 12 x 8 Tube PA /8 NPT O-Ring to 17 x 12 Tube PA /2 NPT O-Ring to 17 x 12 Tube PA m A24217 & 1.m A Flexible connections for Drums & Cylinders, Tested.
13 Revised: 1st January hydro Gas Chlorinators PRICE LIST Standard Accessories supplied with series 9 Chlorinators PA Bottle / Manifold Mount up to 2kg Consisting of: 1 x Cable Tie CT-2-4C 1 x Insect Screen A x O-Rings - Ejector OH-BUN x Lead Cylinder Gaskets LG-1 1 x Squeeze Bottle for Amonia A x Cylinder Spanner A x Filter - Teflon VRH x Replacement Filter VRH meters Vacuum Tubing 12 x 8 A Ton Mount from 2 to 1kg PA24278 Consisting of: 1 x Cable Tie CT-2-4C 1 x Insect Screen A x O-Rings - Ejector OH-BUN x Lead Cylinder Gaskets LG-1 3 x Lead Gasket G x Squeeze Bottle for Amonia A x Cylinder Spanner A x Replacement Filter VRH meters Vacuum Tubing 12 x 8 A Note: 1kg uses 17x12 vacuum tube
14 14 Revised: 1st January 28 hydro Gas Chlorinator Service Kits 9 series 2kg Vacuum Regulator PA $ 86 Item Part No Description Qty 9 OH-VIT-114 O-Ring 1 15 OH-VIT-212 O-Ring 1 19 OH-VIT-112 O-Ring 1 22 VRH Filter 1 26 OH-VIT-11 O-Ring 1 31 OH-VIT-332 O-Ring 1 35 OH-VIT-28 O-Ring PS-112 O-Ring 2 9 series 4kg Vacuum Regulator PA $ 81 Item Part No Description Qty 9 OH-VIT-114 O-Ring 1 15 OH-VIT-212 O-Ring 1 19 OH-VIT-112 O-Ring 1 22 VRH-11-5 Inlet Screen 1 23 VRH Filter Floss 1 26 OH-VIT-11 O-Ring 1 31 OH-VIT-332 O-Ring 1 35 OH-VIT-28 O-Ring PS-112 O-Ring 2 9 series 1kg Vacuum Regulator PA $ 79 Item Part No Description Qty 9 OH-VIT-114 O-Ring 1 15 OH-VIT-212 O-Ring 1 19 OH-VIT-112 O-Ring 1 22 VRH-11-5 Inlet Screen 1 23 VRH Filter Floss 1 26 OH-VIT-11 O-Ring 1 31 OH-VIT-332 O-Ring 1 35 OH-VIT-28 O-Ring PS-112 O-Ring O-Ring 1 9 series 2-4kg Ejector PA $ 129 Item Part No Description Qty 4 OH-CEM-21 O-Ring 1 6 DIH-14-5 Diaphragm 1 7 DIH-15-5 Diaphragm Support 1 8 EJH Diaphragm Nut 1 11 OH-BUN-121 O-Ring PS-112 O-Ring 1
15 Revised: 1st January hydro Gas Chlorinator Service Kits 9 series 1kg Ejector PA $ 133 Item Part No Description Qty 4 OH-CEM-21 O-Ring 1 6 DIH-14-5 Diaphragm 1 7 DIH-15-5 Diaphragm Support 1 8 EJH Diaphragm Nut 1 13 OH-BUN-121 O-Ring RS-116 O-Ring 1 9 series 75-2 g/hr Remote Meter PA24286 $ 53 Item Part No Description Qty 3 OH-VIT-6 O-Ring 2 6 OH-VIT-1 O-Ring 1 7 OH-VIT-11 O-Ring 1 9 GAH-VIT-11 Meter Gasket 2 g/hr 2 9 GAH-VIT-12 Meter Gasket 5 g/hr 2 9 GAH-VIT-13 Meter Gasket 2 g/hr 2 13 OH-VIT-112 O-Ring 2 16 OH-VIT-12 O-Ring PS-112 O-Ring 2 9 series 4 kg/hr Remote Meter PA $ 53 Item Part No Description Qty 3 OH-VIT-6 O-Ring 2 6 OH-VIT-1 O-Ring 1 7 OH-VIT-11 O-Ring 1 9 GAH-VIT-14 Meter Gasket 4 kg/hr 2 13 OH-VIT-112 O-Ring 2 16 OH-VIT-12 O-Ring PS-112 O-Ring 2 9 series 1 kg/hr Remote Meter PA $ 66 Item Part No Description Qty 4 OH-VIT-1 O-Ring 2 5 OH-VIT-112 O-Ring 1 6 GAH-VIT-116 Meter Gasket Top 1 8 OH-VIT-12 O-Ring 2 11 GAH-VIT-115 Meter Gasket Bottom 1 12 OH-VIT-212 O-Ring RS-116 O-Ring 2 Seal Kit for Omni-Valve for up to 1 kg for 2 to 4 kg O-Ring and Valve Seat Seal Kit PA24292 $ 16 O-Ring and Valve Seat Seal Kit PA $ 143
16 16 Revised: 1st January 28 hydro Gas Chlorinators PRICE LIST Service Kits Part No: List Price Service kit for Hydro HGC-5 and 2 2 kg/h and 4 kg/h Vacuum Regulator PA $ 215 Consisting of: 2 x O-Ring 3PS-29 1 x O-Ring 3PS-16 2 x O-Ring 3PS-11 2 x O-Ring 3PS x O-Ring 3PS x O-Ring 3PS x O-Ring 3RS-6 1 x O-Ring 3RS-9 1 x O-Ring 3RS-1 2 x O-Ring 3RS-12 1 x O-Ring 3RS-14 1 x O-Ring 3RS-16 1 x Gasket (Lead) LG-1 4 x Gasket MG-1 *** 1 x Seat YP-11A 2 x Filter T-21 (Note: for 2 series S-275 Filter) *** Note: Please advise Flow Meter capacity. Service kit for Hydro HGC-7 1 kg/h Vacuum Regulator PA $ 194 Consisting of: 1 x O-Ring 3PS x O-Ring 3PS x O-Ring 3PS x O-Ring 3PS-29 1 x O-Ring 3RS-6 1 x O-Ring 3RS-9 1 x O-Ring 3RS-1 1 x O-Ring 3RS-12 1 x O-Ring 3RS-14 1 x O-Ring 3RS x O-Ring 3RS-23 2 x O-Ring 3RS x O-Ring 3PS x Gasket (Lead) LG-1 1 x Gasket (Lead) LG x Seat YP-11A 1 x Filter S x Filter Pad FG-4 NOTE: Recommended grease - Molykote FS3452 $ 98
17 Revised: 1st January hydro Gas Chlorinators PRICE LIST Part No SERVICE KITS List Price Auto Changeover for 5, 2 and 7 series SO1 2kg, SO2 4kg, SO5 1kg PA $ 18 Consisting of: 2 x Rolling Diaphragm SM x O-Ring 3RS-23 2 x O-Ring 3RS-23 2 x Diaphragm Nut SM-111 EJ-1 2 kg Ejector 5 series PA $ 98 Consisting of: 1 x O-Ring 3RS-23 2 x O-Rings 3PS x Rolling Diaphragm SM x Check Assembly Nut E-552 EJ-2 2 series 4 kg & EJ-5 7 series 1 kg Ejector PA $ 98 Consisting of: 1 x O-Ring 3RS-23 2 x Gasket 3PS x Rolling Diaphragm SM x Check Assembly Nut E-552 Vacuum Regulator Diaphragm Assy for 5, 2 and 7 series 2-1kg PA $ 369 Consisting of: 1 x Front Plate DP1A 1 x Rear Plate DP11A 1 x Bolt DP-12A 2 x Diaphragm DP-13 2 x O-Rings 3PS-29 Ejector Diaphragm Assembly for 5, 2 and 7 series PA $ 148 Consisting of: 1 x Rolling Diaphragm SM x Nut E x Check Assembly Bolt E-553 Change Over Unit Diaphragm Assy for 5, 2 and 7 series 2-1 kg PA $ 463 Consisting of: 2 x Diaphragm bolt SM-11 2 x Diaphragm Nut SM x Rolling Diaphragm SM-112
18 18 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Description Inch mm Part No.2 kg/hr = No 16 nozzle, orifice CHN kg/hr = No 13 nozzle, orifice CHN kg/hr = No 15 nozzle, orifice CHN kg/hr = No 12 nozzle, orifice CHN Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro-Ejector selection chart EJO-1-CL2
19 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Description Inch mm Part No.2 kg/hr = No 16 nozzle, orifice CHN kg/hr = No 13 nozzle, orifice CHN kg/hr = No 15 nozzle, orifice CHN kg/hr = No 12 nozzle, orifice CHN Hydro-Ejector selection chart EJO-1-CL2
20 2 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Description Inch mm Part No.2 kg/hr = No 16 nozzle, orifice CHN kg/hr = No 13 nozzle, orifice CHN kg/hr = No 15 nozzle, orifice CHN kg/hr = No 12 nozzle, orifice CHN Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro-Ejector selection chart EJO-1-CL2
21 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Description Inch mm Part No.2 kg/hr = No 16 nozzle, orifice CHN kg/hr = No 13 nozzle, orifice CHN kg/hr = No 15 nozzle, orifice CHN kg/hr = No 12 nozzle, orifice CHN Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Conversion US GPM to LPM x Hydro Ejector selection chart EJO-1-CL2
22 22 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro Ejector selection chart EJO-25-CL2 Conversion US GPM to LPM x
23 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro Ejector selection chart EJO-5-CL2
24 24 Revised: 1st January PSI BAR Conversion US GPM to LPS x.2271 US GPM to LPM x Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro Ejector selection chart EJH-1-CL2
25 Revised: 1st January PSI BAR Conversion US GPM to LPM x Ensure maximum case pressure of booster pump is OK. 2. All pressures shown in PSI. 3. For clean water use only. 4. Solution lines longer than 3m, step up to next size to reduce friction loss. 5. Pump suction pressure must be equal to ejector back pressure. 6. For conditions not shown, contact ProMinent office. Hydro-Ejector selection chart EJH-2-CL2
26 26 Revised: 1st January 28
ProMinent Gas Chlorination
ProMinent Gas Chlorination ProMinent Australia Head Office - Sydney Unit 4, 4 Narabang Way BELROSE NSW 2085 PO Box 85, BELROSE WEST NSW 2085 Ph: (02) 9450 0995 Fax: (02) 9450 0996 Fax (02) 9450 0994 -
More informationHighest Quality. Gas Chlorination Systems
Highest Quality Gas Chlorination Systems Application: Gas chlorination systems are used for water disinfection and other purposes in a variety of applications. Compared to other disinfection methods, chlorine
More informationHGC-200 Hydro Gas Chlorinator
HGC-200 Hydro Gas Chlorinator ProMinent Fluid Controls Pty Ltd Head Office: Unit 4, 4 Narabang Way BELROSE NSW 2085 AUSTRALIA (PO Box 85, BELROSE WEST NSW 2085) Phone: (02) 9450 0995 Fax: (02) 9450 0996
More informationChlorinator. MODEL C-731 (Floor Mounted)
Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive
More informationPART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:
PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and
More informationChemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200
Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed
More informationCAPITAL CONTROLS SERIES NXT3000
CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing
More informationCapital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.
Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationAutomatic Switchover Gas Chlorination Systems Series 900
Automatic Switchover Gas Chlorination Systems Series 900 Instruction Manual All Hydro Instruments Chlorination systems are carefully designed and tested for years of safe, accurate field service. All Hydro
More informationVacuum Operated Liquid Chemical Feed Systems
Vacuum Operated Liquid Chemical Feed Systems Instruction Manual All HYDRO Chemical Feed systems are carefully designed and tested for years of safe, accurate field service. All HYDRO systems are tested
More informationGRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide
GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting
More informationModel VR6 System. Installation, Operation & Maintenance
Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments
More informationChemical Injection Technologies Installation/Service Bulletin
Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS
More informationVACCUPERM Vacuum chlorine gas dosing systems
VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationChlorine Supply Containers And Piping
Chlorine Supply Containers And Piping Containers Chlorine is packaged in containers as a liquefied gas under pressure, resulting in the container having both a liquid phase and a gas phase. When removing
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationChlorinator MODEL MK-I
Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable
More informationFull-Vacuum Chlorinator C 2212 MB / 1
MB 2 04 12 / 1 Purpose of full-vacuum chlorinators Chlorine gas is important for the disinfection of potable and swimming pool water but also represents a source of danger as far as handling, transportation
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationTaking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System
Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System OVERVIEW V10k - THE NATURAL EVOLUTION OF THE WORLD S BEST CHLORINATOR The V10k is a remote vacuum solution feeder for use
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationV10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS
V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS V10K SYSTEM: PROVEN TECHNOLOGY WORLDWIDE IN USE Since Charles F. Wallace and Martin F. Tiernan discovered the first chlorine gas feed system in 1913 the
More informationGas Chlorination Systems Series E5000 Up to 100ppd Instruction Manual
Gas Chlorination Systems Series E5000 Up to 100ppd Instruction Manual All ENCHLOR Chlorination systems are carefully designed and tested for years of safe, accurate field service. All ENCHLOR Chlorination
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationFOAM TANK (1/2) DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationVaccuperm accessories
GRUNDFOS DATA BOOKLET Vaccuperm accessories for chlorine gas dosing systems Vaccuperm accessories Table of contents 1. General 3 Principle of vacuum chlorine gas dosing systems 3 2. 4 Installation accessories
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationPLUMBING WATER & GAS TRADE CATALOGUE
PLUMBING WATER & GAS TRADE CATALOGUE 2015 Index Plumbing, Water & Gas Hoses & Fillers P-04 Tanks Containers Accessories P-07 PumpsP-11 Water is our most precious resource and a necessity when camping and
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%
More informationTECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE
Page 1 of 10 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm and flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge
More informationSection GAS CHLORINATION SYSTEM
PART 1 GENERAL 1.01 SUMMARY Section 11260 This Section includes the furnishing and subsequent installation, complete and in place, of a functioning gas chlorination disinfection system for water as shown
More informationVaporizer Piping Liquid Chlorine Manifolds
T #1 = 1234 1 1 Vaporizer Piping iquid Chlorine anifolds Vaporizers are used for high capacity chemical feed applications when direct gas withdrawal systems are impractical. This document will provide
More informationMEDICAL EQUIPMENT CATALOG
THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationTECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:
February 11, 2005 Deluge Valves 218 a 1. PRODUCT NAME Viking Model F-1 Deluge Valve 8" - Manufactured since 2002 4" & 6" - Manufactured since 2003 2-1/2" & 3" - Manufactured since 2004 2. MANUFACTURER
More informationNothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump
Page 1 of 6 TPS Australia - Quality hand-made instruments since 1968. Nothing's as cool, as a freshwater pool easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Automatic
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationAbout. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.
REGULATORS 1 About Bromic Plumbing & Gas provide a wide variety of regulators to suit applications from recreational to professional, in both Natural Gas & LPG (propane). Our range of regulators includes
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationFITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI
Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationPipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3
Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection
More informationWIDDER TOOLS. HPICAL Calibration Station 1 (203)
WIDDER TOOLS HPICAL-15000 Calibration Station WWW.WIDDERTOOLS.COM 1 1. TEST SET-UP a. Be sure air and water supply lines are installed per basic set-up & installation instructions supplied with calibration
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationPressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
More informationHYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6
INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationModulating liquid level regulators, servo-controlled PMFL / PMFH and SV
MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,
More informationStandard Grout Header. Protected Pressure Gauge. High Pressure Gauge. In-Line Grout Header. Inline Protected Pressure Gauge
G A U G E S G R O U T H E A D E R S Protected Pressure Gauge In-line mounting accurately measures grout discharge pressure. Gauge is equipped with quick disconnect fittings that easily snaps into grout
More informationINSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW
INSTRUCTION MANUAL FOR Chlorinator M 3600 C 2014 Controlmatik ABW 1 CONTENTS 1. General... 3 2. Operation... 4 2.1 Automatic control... 6 2.2 Manual control - 1... 6 2.3 Manual control - 2... 6 3. Motor
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationJet Swim Installation instruction
Jet Swim 2000 Jet Swim 2000 Liner pool 1. Remove the stainless steel front plate and cut out the pool wall according to the hole pattern. The center of the Jet Swim housing must be a minimum of 170 mm
More informationFOAM TANK (1/2) DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS
More informationSection 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index
Section 3000 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR...36 Versatile type of lubrication able to feed liquid to elevated, distant or inaccessible points. CONVEYOR CHAIN LUBRICATION SCHEMATIC...39
More informationLiquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
More informationInstruction Manual ADVANCE Series 480 Vacuum Regulator
Instruction Manual ADVANCE Series 480 Vacuum Regulator 80 60 40 20 R - 1-100.6001.15 These instructions describe the installation, operation and maintenance of the subject equipment. Failure to strictly
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationFloat valves Types SV 4, SV 5 and SV 6
Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationTECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)
Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge
More informationTECHNICAL DATA. Pressure Regulation 531a. April 24, 2009
April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationSeries OV-110 Omni-Valve
Series OV-110 Omni-Valve Instruction Manual The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on our
More informationMAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump
A. PARTS MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump Assembly & Operating Instructions Parts for liquid chlorine pump head 1pc. 1/4 poly delivery tubing, 4 meters 1pc. drum
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationTECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)
November 30, 2007 Deluge Valves 218a DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm and fl ood valve with one moving mechanism. The Deluge Valve is used to control
More informationInstruction Manual Series 200 ADVANCE Cylinder or Ton Container Mounted Vacuum Regulators
Instruction Manual Series 200 ADVANCE Cylinder or Ton Container Mounted Vacuum Regulators 100 & 250 PPD (2 & 5 kg/h) Cylinder Mounted 500 PPD (10 kg/h) Cylinder Mounted 500 PPD (10 kg/h) Ton Container
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationAIR FOAM CHAMBER DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET AIR FOAM CHAMBER DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationUniversal Charging and Testing Unit FPU-1
1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose
More informationLP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957
LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957 Enerco, based in Cleveland Ohio, has been at the forefront of infrared technology since 1957. This market leading technology has allowed Enerco to build
More informationTECHNICAL DATA OBSOLETE
August 2, 2006 Foam 70a 1. DESCRIPTION A Hi-Expansion Foam System is a standard deluge system capable of discharging a foam/water solution automatically through open Hi-Ex Generators. A Hi-Expansion Foam
More informationElectro Controls. Pressure WattsIndustries.co.uk
Electro Controls Pressure - 07 WattsIndustries.co.uk PRESSURE AIR DIFFERENTIAL PRESSURE SWITCHES EDA.. EFS.. To monitor air flow, dirty filters, flue draught, frost on coils & level. For positive, negative,
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationValve Closure Systems for Plug-Type Angle Valves or Ball-Type Angle Valves
Powell Valve Closure Systems for Plug-Type Angle Valves or Ball-Type Angle Valves UniPro Pneumatic Valve Closure System UniPro R Pneumatic Valve Closure System UniPro LT Pneumatic Valve Closure System
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationSanitizers. Sanitizers. Sanitizers for Pools & Spas
for Pools & Spas 207 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely,
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationSeries OV-110 Omni-Valve
Series OV-110 Omni-Valve Instruction Manual The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on our
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More information