METERING PROFILE GAS WATER & ASSOCIATED CONTROLS
|
|
- Camilla Teresa Richard
- 6 years ago
- Views:
Transcription
1 ABN METERING PROFILE GAS WATER & ASSOCIATED CONTROLS Accutherm International is a specialist company supplying high quality gas control products, engineering services and support to all sectors of the gas market. Head Office (Melbourne) Sydney Brisbane (Distributor) 1/5 Samantha Court 2/14 Welder Road 17 Medway Street Knoxfield VIC 3180 Seven Hills NSW 2147 Rocklea QLD 4106 T: T: T: F: F: F: sales@accutherm.com.au sales@gascomponents.com.au
2 Rotary Gas Meters Turbine Gas Meters Diaphragm Gas Meters Turbine Gas Meters GAS Electronic Volume Correctors Dataloggers & Communication Hot & Cold Water Meters WATER Gas Control Equipment Regulators Filters Slam Shut & Relief Valves
3 FMG FLOW METER GROUP FMG specialises in the development and manufacture of energy and gas measurement systems. Located in the Netherlands, FMG produces a wide range of rotary and turbine gas meters, volume conversion devices, master meters and calibration benches. Unique product features include self-diagnosis and tamper prevention. Their wide range includes models from 25 m3/h up to 6500 m3/h flow rates. Pressures ratings range from atmospheric, up to 100 bar. All FMG meters comply with international safety and metrological standards. FMG FMR ROTARY GAS METER The FMR series of rotary gas meters are designed to meet the highest demands of reliable and accurate measurement of gas flow. There compact exchangeable aluminum cartridge allows local repair and on-site cleaning. Installation stresses caused by connecting piping are minimal due to the robust design and construction of the casing and cartridge. Range from 0.5 to 650 m³/h Connection sizes: DN40 to DN150 Connection type: BSP threaded, PN16, ANSI150 and ANSI600 flanged Maximum operating pressure: up to 30 Bar Low frequency pulse output standard High frequency pulse output optional FMG FMT-L TURBINE METER The FMT-L series turbine meters are designed to perform on the highest level of accuracy. The 3 x DN aluminum cartridge with integrated straightening vanes guarantees a high level of accuracy, even under sever flow conditions. The cartridge can be pre-calibrated, under both low and high pressure conditions then exchanged on-site. Range from 8 to 6,500m³/h Connection sizes: DN80 to DN300 Connection type: PN16,25,40,64,100, ANSI150,300,600 Low frequency pulse output standard High frequency pulse output optional
4 GA SERIES DIAPHRAGM GAS METERS GA Series diaphragm gas meters are suitable for cost effective sub metering domestic, commercial and industrial applications. Available with pulse output capable of linking with most data loggers or management systems. Standard sizes fit common connections Made of steel which is polyester powder plastic coated ideally suitable for outdoor applications Measures flow mediums of natural gas, LPG and air. Can be supplied with or without pulse output. Cost effective Each meter is fully tested for accuracy Simple connection to pressure regulators(also available from Accutherm) The performance and parameters comply with the following Standards: AS (Domestic diaphragm gas meters) EN (Gas meters. Diaphragm gas meters) Data sheets available on request. Model: Minimum Flow: m³/hr Nominal Flow: m³/hr Maximum Flow: m³/hr G G G G G G
5 GWF RADIAL BLADE TURBINE METERS GAS GWF srl manufacturer s high quality gas measurement equipment and is the daughter company to the renowned Swiss meter manufacturer GWF AG Luzern. High quality Standard range includes models from 25 to 650 m³/hr Connection sizes of DN50, DN80 and DN100 PN16 flange connection Rated to 6 Bar Low frequency pulse output standard High frequency optional ELGAS SRO Elgas sro specialises in the development, manufacture and supply of data collection equipment in the gas and energy industry. They have smart metering solutions such as volume converters, dataloggers and other communication systems. Elgas minielcor Electronic Volume Corrector The minielcor is battery powered EVC, it is suitable for hazardous areas applications as the device is available with an optional external intrinsically safe power supply. The system uses secure sealed switches to prevent unauthorised configuration changes and obtaining unauthorised data from the device. It comes equipped with a six button keyboard and backlit graphic LCD display. Users can easily check instant values, device parameters or archives.
6 ELGAS SRO Cont. One channel Electronic Volume Converter (EVC) Designed to be used for installation in hazardous area Zones 0, 1 and 2 Battery lifetime more than 5 years Fully configurable device (Telves PC Software included) Graphical backlit LCD display 128 x 64 pixels Possibility to connect 3rd pressure or temperature sensor Possibility to connect second EVC as subsystem Typical error under reference conditions < 0.15 % from measured value (<0.5 % - MID) Certificate FTZU 08 ATEX 0324X Protection class IP 66 Working temperature -25 C to +70 C Communication: Serial interface: RS232 / RS485, Optical interface: IEC Four digital inputs/outputs Optional Accessories: Infrared USB Head HIE-04 Current Output Module CL-1 (4-20 ma) 240V External Power Supply GWF WATER METERS WATER GWF MessSysteme AG is the market leader in Switzerland and proven measuring instrument manufacturer. GWF has developed modern data technology and innovative measuring systems. GWF have been setting standards in measuring data acquisition. Their high-precision measuring instruments are combined with developed and globally installed GWFcoder technology, in addition to advanced and reliable ICT. They guarantee intelligent smart metering system solutions with enhancing energy efficiency
7 GWF WATER METERS Cont. UNICO Single Jet Water Meter WATER GWF UNICO Single Jet water meter is suitable for cold water application up to 30 C, warm water applications up to 90 and hot water applications up to 120 C. The UNICO Meter is available in DN15 and DN20. It is suitable for measurement of low flow rates up to 2.5 m 3 /hr nominal flow rate. It is a robust design with high grade wear resistant materials and has an excellent measuring stability and reliability. Single jet dry-dial meter with magnetic coupling Register can be turned for best readout position Maximum operating pressure PN 16 bar Maximum operating temperature: 30 C, 90 C, 120 C Horizontal or vertical installation 5 dial resolution High grade wear resistant and corrosion proof materials Inlet strainer Reconditionable and recyclable execution Conformity to EEC Standard Available with IP14 Pulse Generator. UNICOcoder models with Modbus interface EN /3 MT Multi Jet Water Meter GWF MT Multi Jet water meter range is available in the MTK cold water models, suitable for applications up to 30 C. The MTW warm water models are suitable for applications to 90 C and the MTH hot water models, suitable for applications up to 130 C. Sizes are available in DN15 to DN50 in threaded and flanged models are available in sizes from DN20 to DN50. The horizontal models are suitable for nominal flow rates up to 15 m 3 /h and 10 m 3 /hr nominal flow for vertical models. It is a robust meter with a long service life and high grade wear resistant materials. It has an excellent measuring stability and reliability.
8 GWF WATER METERS Cont. WATER Horizontal or vertical installation (Vertical riser/down pipe) Register can be turned through 360 Maximum operation pressure PN 16 bar (Flanged PN 25 bar) Maximum operating temperature: 30 C, 90 C or 130 C SVGW Certification, Conformity according to EEC Standard Available with IP14 Pulse Generator MT_coder models with Modbus interface EN /3 Woltman Water Meter GWF Woltman water meter range is available in the WPDK cold water meter models are suitable for applications up to 50 C. The WPDH hot water meter models are suitable for applications up to 130 C. Sizes are available in flanged connection from DN50 to DN300. The WPDK cold water meter range is suitable for nominal flow rates up to 1400 m³/hr. The WPDH hot water range is suitable for nominal flow rates up to 600 m³/h. The Woltman range is a robust design with high grade wear resistant materials, it has an excellent measuring stability and reliability. It has a removable measuring insert which is easily replaceable and retrofitted. Universal installation position Straight flow section 3xDN Register can be turned through 355 Maximum operating pressure PN16 bar Maximum operating temperature: 50 C or 130 C SVGW certification Flood proof standard pulser register (IP68) with ports for two Reed-RD-Pulsers and one Opto-OD- Pulser
9 PIETRO FIORENTINI Pietro Fiorentini, have over 60 years experience in the design, manufacture and supply of components, systems and services to the transmission, distribution and domestic gas markets. GOVERNER Regulators Fiorentini Minireg spring-loaded governors are designed and built to comply with UNI EN 88 class A group 2 specifications and can be used for all types of natural gas, LPG or non-corrosive gases. These regulators are widely used in supply lines for mixed and combined burners and in the piped distribution of methane gas and LPG in both industrial and non-industrial applications. Compact models: DN15, DN20, DN25 Low pressure OPSO models: DN20 & DN25 Full capacity models: DN15 to DN100 Spring loaded Self-acting with balanced stem and seat Double safety diaphragm Enables internal use without connecting an external vent pipe Supplied with internal sensing line and inlet/outlet pressure test points Limited venting to atmosphere Easy installation Recyclable Aluminium body Compact lightweight design Inbuilt filter available External test points
10 PIETRO FIORENTINI Cont. FE Series OPSO Regulator The FE series of two stage self-driven spring loaded regulators are widely used in installations using natural gas, LPG and other non-corrosive gases. They are designed for either direct installation to a gas meter or used in general pipeline work. Balanced double stage (2 stage) Includes Over Pressure Shut Off (OPSO) Rated 8.6 Bar Available in: 25m³, 50m³, 75m³ and 100m³ models Self Driven High accuracy High operating reliability Simple installation procedure Limited venting Option to have a double main diaphragm for extra safety Multiple connections to suit most installations External test points Perfect complement for Accutherm meters Inbuilt filter 100 micron Underground models available Model FE25 Model FEX Model: Capacity Outlet Range: mbar Inlet Connection: BSP Outlet Connection: BSP FE25-BP 25 m³ mm 25mm FE25-TR 25 m³ mm 25mm FES-BP 50 m³ mm 25mm FES-TR 50 m³ mm 25mm FEX-BP 75 m³ mm 40mm FEX-MP 75 m³ mm 40mm FEXS-BP 100 m³ mm 40mm FEXS-MP 100 m³ mm 40mm
11 PIETRO FIORENTINI Cont. HP100 First Stage LPG Regulator The HP100 series of spring loaded, diaphragm controlled balanced plug regulators are suitable for medium and high pressures. They are widely used in the distribution of Natural Gas, and LPG where good performance of regulation and fast response to flow rate variations are required. Most commonly used as 1st stage reduction for domestic, commercial and industrial LPG applications. It has a 25mm NPT connections and includes over pressure shut off (OPSO). DIVAL 500 Regulator The Dival 500 series of spring loaded, diaphragm controlled balanced plug regulators are suitable for low, medium, and high pressure. Divals and shut-off device series regulators are supplied with internal sensing lines. Both the regulator and the shut-off device can be set for suitable pressure ranges. DIVAL 600 Regulator The Dival 600 series of direct acting regulators are suitable for low and medium pressure applications controlled by a diaphragm and counter spring. Modular design of this series allows the installation of an incorporated slam shut or device for use as in line monitor on the same body without changing the face-to-face dimension. It has an open top entry design, allowing easy periodical maintenance without removing body from the line. 106 Gas Filter The 106 series of gas filters are designed to filter non-corrosive dry gases at 50 microns. Rated to 10 bar, they are available in BSP threaded models from DN15 to DN50. Flanged models are available in DN50 to DN100 which universal flange suiting ANSI150 and PN16. Model DN150 is 2 Bar rated.
12 ACCU-TEST GAS SAFETY SHUT OFF SYSTEM The ACCU-TEST is an emergency shut off system which is purposely designed to prevent gas being restored to open unsafe downstream piping, appliances and outlets after loss of power or in the case of an emergency. Assembled ready to install Simple Installation Available in 24V AC or DC and 240VAC AGA Approved Gas Valves Key lockable Isolator Can be wired into fire alarm and/or an emergency stop Standard Low Pressure 240V Systems: Acc Part Number: Size: NG LPG MJ/hr m³/h MJ/hr m³/h LS FS 015 ACCU 240V 15mm LS FS 025 ACCU 240V 25mm LS FS 040 ACCU 240V 40mm LS FS 050 ACCU 240V 50mm LS FS 065 ACCU 240V 65mm LS FS 080 ACCU 240V 80mm *Flow rates based on 2 mbar pressure drop For different voltages, sizes or pressures please call S:\SALES & MARKETING\ADVERTISING & MARKETING\ACCUTHERM PROFILES\ACCUTHERM METERING PROFILE MAY 2014.DOC
1800C and 1800C-HC Service Regulators
SB 855.9 800C and 800C-HC Service Regulators Maximum Pressure 5 Table of Contents 800C Regulator Information...................... 800C-HC Regulator Information.................. 800C and 8C Service Regulators...............
More informationDival 600. Pressure Regulators
Dival 600 Pressure Regulators Pressure regulators Dival 600 Dival 600 series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter
More informationEDUCATION DEPARTMENT ACCU-TEST
ABN 17 100 208 964 EDUCATION DEPARTMENT ACCU-TEST GAS SAFETY SHUT OFF SYSTEM Operating & Installation Manual Head Office (Melbourne) Sydney Brisbane (Distributor) 1/5 Samantha Court 2/14 Welder Road 17
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationModel 1800 PFM Series Regulator. Technical Bulletin
Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane
More information1800CPB2 Service Regulators
SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,
More informationNorval Pressure Regulators
Pressure Regulators Pressure regulators NORVAL pressure regulators are balanced direct acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These regulators
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationUltrasonic Flowmeter USZ 08
Ultrasonic Flowmeter USZ 08 PRODUCT INFORMATION Reliable Measurement of Gas Fields of application, method of operation and construction 2 Fields of application The ultrasonic flowmeter is an advanced measuring
More informatione G) GOVERNOR t,5 ii:i! Line Pressure Regulators
Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informatione G) GOVERNOR t,5 ii:i! Line Pressure Regulators
Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationApplications. Features AWWA ULTRASONIC WATER METER
MEASURE TODAY. ENSURE TOMORROW wprime Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential
More informationPressure regulators. Introduction. TR Head. 3 ways body Dival
Pressure Regulators > Pressure regulators Introduction series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These
More informationDival 500 Pressure Regulators
Dival 500 Pressure Regulators Dival 500 Classification and Range of use The DIVAL 500 is a downstream direct-acting pressure regulator with balanced plug, for low, medium and high pressures. Suitable for
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationSR100 Series Service Regulators. Technical Bulletin
SR00 Series Service Regulators Technical Bulletin Model SR00 Series Regulator 0 Elster American Meter The compact, high capacity SR service regulator is designed for residential or light commercial/industrial
More informationG4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER
Gas Meters content G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER G4S G4S Residential Diaphragm Type
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationRR 16 Commercial & Industrial Regulator
Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations
More informationProduct information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution
Product information FLOWSIC500 Ultrasonic Gas Meter Custody Transfer Measurement in Natural Gas Distribution FLOWSIC500 Ultrasonic Gas Meter Custody transfer measurement in natural gas distribution Product
More informationWATER METERS.
WATER METERS Can be installed Pulse output with both plug & play system horizontal and vertical No straight Higher sections accuracy required U0 D0 Water engineering High resistance Its operation is based
More informationOnline data sheet FLOWSIC500 GAS FLOW METERS
Online data sheet FLOWSI500 FLOWSI500 A F H I J K L M N O P Q R S T US Ordering information Type FLOWSI500 Part no. On request The exact device specifications and performance data of the product may deviate
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationPaul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS
Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS Agenda 1 What do we sell? Flagship Products HON 5020 HON R100 NG HON 512, class 150 Q&A Where Do Honeywell
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationAperval Pressure Regulators
Pressure Regulators Pressure regulators is pilot-controlled pressure regulator for medium and low pressure applications. is normally a fail to open regulator and specificaly will open under the following
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More information1800CPB2 Pilot-Loaded Service Regulators
1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More information1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG
A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council
More informationKMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N
Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :
More informationFAS-W. Features. Applications. Automatic condensation hygrometer
FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature
More informationDigital Mass Flow Meters and Controllers for Gases
Digital Mass Flow Meters and Controllers for Gases A Bronkhorst company. M+W Instruments. Your specialists for inline measurement WORTH KNOWING M+W Instruments was founded in 1988 and has always specialised
More informationReduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Features General application The RP03 provides protection from both backsiphonage and backpressure
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationNorval Pressure regulator
Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable
More informationSafety Shut-off Valve SSV
Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.
More informationProducts for Cryogenic Applications
Products for Cryogenic Applications Cryogenic valves, self-operated regulators, differential pressure meters SMART IN FLOW CONTROL. Designed for cryogenic service Industry, medicine, supply engineering
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationTRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.
TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationT EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions
Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type
More informationPressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG
C US Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve All-purpose servo regulator for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationSHANGHAI FIORENTINI GAS EQUIPMENT CO.LTD.
SHANGHAI FIORENTINI GAS EQUIPMENT O.LTD. Headquarter Beijing Office Nanjing Fiorentini Gas Equipment o.,ltd. Lanzhou Office Xinjiang Office Guangzhou Office 8 Wuhan Office Shenzhen Office Hangzhou Office
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationVortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres
Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate
More informationThe affordable consumption counter for compressed air and gases R 3 /4 (DN 20)
VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More information1800C & 1800C-HC Service Regulators
SB-855.8 800 & 800-H Service Regulators Maximum Pressure 5 PSIG 800 Regulator Information General Information The merican Meter Series 800 pressure regulators are designed for natural gas applications
More informationModulating Valves for Atmospheric, Infrared, and Direct Fired Burners
BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationOnline data sheet FLOWSIC30 GAS FLOW METERS
Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information LTRASONIC GAS FLOW METER FOR CTION Type Part no. On request The exact device specifications and performance data of the product
More informationGovernor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG
Governor with solenoid valve Air/gas ratio control with solenoid valve VAG All-purpose servo-governor for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500 mbar Outlet
More informationFlow and Energy Measurement F-5400 THERMAL MASS FLOW METER
THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air
More informationMicro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationRR 16 Commercial & Industrial Regulator
RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate
More informationRB 4700 Commercial & Industrial Regulator
RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.
More informationDN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1
www.apq.com.es EU Product / Spain DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 Cod. RISUT5000A1 Cod. RISUT5000D1 DESCRIPTION The Suton 50001 Regulator is designed for use in distribution networks
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationLevel, Pressure, and Density Instrumentation for the Petrochemical Industry
Level, Pressure, and Density Instrumentation for the Petrochemical Industry Application Examples and Products Measurement technology for the petrochemical industry This brochure presents examples of applied
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationFlow metering in gases Introduction to COMBIMASS family
Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,
More informationsafety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
More information1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG
SB-8506. B Service Regulators Maximum Inlet Pressure 5 PSIG Measurement Engineers Since 86 www.americanmeter.com B Service Regulators General Information The American Meter Series B pressure regulator
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationVariable Area Flow Meters. VS Series
Variable Area Flow Meters VS Series Precise measuring in water flow Design and function VS series fl ow meters operate with the fl oat principle. A fl oat is located in a conical plastic tube. The fl oat
More informationReduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections
VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both
More informationSlam Shut Valves SCN
Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever
More informationSafety Shut-Off Valve HON 720
Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable
More informationTransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationProduct Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12
Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationSize : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic
More informationVortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing
Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual
More informationMODEL 273PL GAS PRESSURE REGULATOR
Edition GD273PL.06.USA BRYAN DONKIN RMG USA Serving the Gas Industry WORLDWIDE Applications Primarily utilized for commercial, industrial and multi-installation applications For natural gas and all non-corrosive
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationRMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations
RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry has a growing demand for operational excellence. Pilot-operated
More informationRegulator from 1800 B series
Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationERZ 2000-NG Flow Computer
ERZ 2000-NG Flow Computer With decades of natural gas measurement experience, RMG has developed the ERZ 2000-NG an approved and best-in-class gas flow measurement solution for all areas of gas volume conversion.
More informationElectronic Volume Correctors
Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute
More information