Technical Data - Pressure Losses profi-air Heat-recovery ventilation
|
|
- Claribel Scott
- 6 years ago
- Views:
Transcription
1 Technical Data - Pressure osses profi-air Heat-recovery ventilation DRAINAGE SYSTEMS EECTRICA SYSTEMS BUIDING TECHNOOGY INDUSTRIA PIPES
2 Table of Contents profi-air refreshingly easy... profi-air pipe types profi-air tunnel pipe 3 profi-air classic pipe 4 profi-air fittings profi-air tunnel fittings 5 13 profi-air distributors profi-air distributors / distributor accessories profi-air accessories profi-air iso pipe profi-air external wall grill 2 profi-air roof hood 21 profi-air valves / ventilation grills FRÄNKISCHE profi-air technical data
3 Technical data sheet profi-air tunnel pipe Tunnel-shaped, crush-resistant, double-walled corrugated pipe with antistatic and antibacterial inside coating, to be installed in the insulation layer, for routing cabels in suspended ceilings, installation walls, risers or frames. The smooth inner surface of the profi-air tunnel pipe allows for easy cleaning and enables high flow rates. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. Delivered coiled and sealed with pipe plugs. Admissible operating temperature: -25 to 6 C 2m W H n flat, flexible crush-resistant design n min. 6cm horizontal bend radius n smooth, antistatic and antibacterial inside coating n high flow rates of max. 45m³/h n air distribution system made entirely of PE profi-air tunnel pipe in coils W H Coil ø Coil height mm mm mm mm kg/coil x52 mm PE-HD m max 45 m 3 /h FRÄNKISCHE profi-air technical data 3
4 Technical data sheet profi-air classic pipe Highly flexible double-walled corrugated pipe with antistatic and antibacterial internal coating, to be installed in concrete ceilings, suspended ceilings, installation walls, risers or frames. The profi-air classic pipe with its smooth inner pipe surface allows easy cleaning. A profi-air profile sealing ring that is mounted onto the second rib of the corrugations of the profi-air classic pipe is used to connect to the profi-air classic pipe or a fitting. Admissible operating temperature: -25 to 6 C n highly flexible and durable D i D o n min. 15 cm horizontal bend radius 2m / 5m n antistatic and antibacterial inside coating n smooth inner surface for easy cleaning n air distribution system made entirely of PE n hygienic transport - end plug and individual packing profi-air classic pipe in coils D o / D i Coil ø Coil height mm mm mm kg/coil NW / PE-HD 6.8 2m NW / PE-HD 17. 5m NW 9 91 / PE-HD 9. 2m / max 3 m 3 /h max 45 m 3 /h FRÄNKISCHE profi-air technical data
5 Technical data sheet profi-air tunnel 9 vertical bend 9 degree bend to vertically redirect air flow without being obstructed by edges to easily, quickly and without tension connect the profi-air tunnel pipe system. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. H n flat design provides space-saving redirection n direct connection of two fittings possible n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing W profi-air tunnel 9 vertical bend W H mm mm mm kg/pc. pc x 52mm PE-HD * *Including profi-air sealing and connection element, Part. No FRÄNKISCHE profi-air technical data 5
6 Technical data sheet profi-air tunnel 9 horizontal bend 9 degree bend to horizontally redirect air flow without being obstructed by edges to easily, quickly and without tension connect the profi-air tunnel pipe system. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. H n flat design provides space-saving redirection n direct connection of two fittings possible n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing W profi-air tunnel 9 horizontal bend W H mm mm mm kg/pc. pc x 52mm PE-HD * *Including profi-air sealing and connection element, Part. No FRÄNKISCHE profi-air technical data
7 Technical data sheet profi-air tunnel 9 air outlet H 3 W H 2 9 degree air outlet housing to connect to a valve. Can be universally used for supply air or extract air. Optional filters for extract air are available. Can be installed in walls, floors or ceilings. Can be mounted by using fastening lugs. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. H H 1 n flexible use in walls, floors and ceilings n direct connection of two fittings possible n flow-optimised design n fastening lugs at the module D i n air distribution system made entirely of PE D o n hygienic individual packing profi-air tunnel 9 air outlet for valve Ø125mm D i D o W H / H 1 / H 2 / H 3 mm mm mm mm mm kg/pc. pc x 52mm , / 32 / 79 / 52 PE-HD * *Including profi-air sealing and connection element, Part. No FRÄNKISCHE profi-air technical data 7
8 Technical data sheet profi-air tunnel straight air outlet Straight air outlet housing to connect ti a valve. Can be universally used for supply air or extract air. Optional filters for extract air are available. Can be installed in walls or ceilings. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. n flexible use in walls or ceilings 1 2 n direct connection of two fittings possible n flow-optimised design H D o D i n air distribution system made entirely of PE n hygienic individual packing W profi-air tunnel straight air outlet for valve Ø125mm D i / D o W H / 1 / 2 mm mm mm mm kg/pc. pc x 52mm 125 / / 195 / 13 PE-HD * *Including profi-air sealing and connection element, Part. No FRÄNKISCHE profi-air technical data
9 Technical data sheet profi-air tunnel 9 air outlet 9 degree air outlet housing to cover grills. Can be universally used for supply air or extract air. Can be installed in walls or floors. Can be mounted by using fastening lugs. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. H W 1 H 2 n flexible use in walls and floors n direct connection of two fittings possible n flow-optimised design n fastening lugs at the module n air distribution system made entirely of PE n hygienic individual packing H 3 3 W 2 profi-air tunnel 9 air outlet for profi-air ventilation grills 78364/ / 2 / 3 W 1 / W 2 H 1 / H 2 / H 3 mm mm mm kg/pc. pc x 52mm 84.5 / 89 / / / 174 / 8 PE-HD * *Including profi-air sealing and connection element, Part. No FRÄNKISCHE profi-air technical data 9
10 Technical data sheet profi-air classic 9 air outlet H 2 W 9 degree air outlet housing to connect to a valve. Can be universally used for supply air or extract air. Optional filters for extract air are available. Can be installed in walls, floors or ceilings. Can be mounted by using fastening lugs. A profi-air profile sealing ring that is mounted onto the second rib of the corrugations of the profi-air classic pipe is used to connect to the profi-air classic pipe and for simultaneaous sealing. H 1 H n flexible use in walls, floors and ceilings n flow-optimised design n fastening lugs at the module n air distribution system made entirely of PE n hygienic individual packing D i D o profi-air classic 9 air outlet for one valve Ø125mm D i / D o W H / H 1 / H 2 mm mm mm mm kg/pc. pc x NW / / 285 / 95 PE-HD FRÄNKISCHE profi-air technical data
11 Technical data sheet profi-air straight adaptor Straight adaptor to quickly and easily connect profi-air tunnel pipes and fittings to profi-air classic fittings. A profi-air profile sealing ring is used to connect to the profi-air classic fitting. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. NW NW n direct connection of round pipes and tunnel pipes n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing W H profi-air straight adaptor profi-air classic to profi-air tunnel W H NW mm mm mm kg/pc. pc x 52mm NW PE-HD * *Including profi-air sealing and connection element, cat. no FRÄNKISCHE profi-air technical data 11
12 Technical data sheet profi-air straight adaptor Straight adaptor to quickly and easily connect profi-air tunnel pipes and fittings to profi-air classic fittings. A profi-air profile sealing ring is used to connect to the profi-air classic fitting. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. NW NW n direct connection of round pipes and tunnel pipes n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing B H profi-air straight adaptor profi-air classic to profi-air tunnel B H NW mm mm mm kg/pc. pc x 52 mm/nw PE-HD, *Including profi-air sealing and connection element, cat. no FRÄNKISCHE profi-air technical data
13 Technical data sheet profi-air 9 adaptor 9 degree adaptor to quickly and easily connect profi-air tunnel pipes and fittings to a profi-air classic pipe. A profi-air profile sealing ring is used to connect to the profi-air classic pipe. A profi-air sealing and connection element is used to connect to the profi-air tunnel pipe or a fitting. In addition, the connection can be secured by using a mounting clamp. H 2 NW H 2 n direct connection of round pipes and tunnel pipes n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing H 1 W profi-air 9 adaptor profi-air classic to profi-air tunnel W H 1 / H 2 NW mm mm mm kg/pc. pc x 52mm/NW / PE-HD x 52mm/NW / PE-HD [NW75] [NW9] * *Including profi-air sealing and connection element, cat. no FRÄNKISCHE profi-air technical data 13
14 Technical data sheet profi-air classic 9 bend 9 degree bend to horizontally/vertically redirect air flow to easily, quickly and without tension connect the profiair classic pipe system. A profi-air profile sealing ring that is mounted onto the second rib of the corrugations of the profi-air classic pipe is used to seal. NW n fittings to directly connect to the profi-air classic pipe n small 6 mm radius n flow-optimised design n air distribution system made entirely of PE n hygienic individual packing NW profi-air classic 9 bend NW mm kg/pc. pc NW PE-HD NW PE-HD [NW75] [NW9] FRÄNKISCHE profi-air technical data
15 Technical data sheet profi-air classic distributor 2 NW W Distribution box, can be used for supply air or extract air, including four mounting angles. Distribution plate can be mounted flexibly, for straight or 9 distribution, inside sound insulation coating and two lateral inspection openings for inspection and cleaning. Constant airflow regulators can be optionnally used in the distributor outlets. 1 D W n flexible use, low height n no cross talk sound attenuation needed thanks to star-shaped installation and sound insulation n two wide inspection openings n constant airflow regulators can be used profi-air classic distributor NW W 1 2 D mm mm mm mm mm kg/pc. pc Distributor, 5-fold DN steel Distributor, 1-fold DN steel Distributor, 15-fold DN steel Straight *Inclusive profi-air manifold coupling FRÄNKISCHE profi-air technical data 15
16 Technical data sheet profi-air classic constant airflow regulator Self-regulating, constant airflow regulator for the profi-air classic distributor, with a wear-free control element in a plastic housing, silicone membrane and a recoil spring to be directly installed in the profi-air classic distributor connection coupling. Automatic, maintenance-free airflow regulation independent from the position, no auxiliary energy needed. Applicable in: / D n self-acting regulating element n reduces start-up time n suited for all profi-air classic distributors n optional self-intensifing element for intensive ventilation profi-air constant airflow regulator D mm mm kg/pc. pc m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone m 3 /h 8 75 PP/silicone FRÄNKISCHE profi-air technical data
17 Technical data sheet profi-air classic self-intensifying element Self-intensifying element for the profiair classic distributor with variable flow rate. Applicable in: / n suited for all profi-air classic distributors n intensive ventilation possible in spite of constant airflow regulator D profi-air self-intensifying element D mm mm kg/pc. pc Ø 8mm 8 54 PP FRÄNKISCHE profi-air technical data 17
18 Technical data sheet profi-air tunnel regulating element Regulating element to compensate for the pressure loss in the air distribution system. Regulated through various clear cross sections. The regulating element can be installed in any profiair tunnel sealing and connecting element. W n suited for any profi-air sealing and connecting element n flexible use n hygienic individual packing H W profi-air tunnel regulating element W H mm mm mm kg/pc. pc x 52mm ,4 2 PP a 3a 2a 1a 1 opening 1 or 1a 1 opening 4 or 4a 2 openings 1 and 1a 2 openings 2 and 2a 2 openings 3 and 3a 4 openings 1, 2 and 1a, 2a 4 openings 3, 4 and 3a, 4a 6 openings 1, 2, 3 and 1a, 2a, 3a 6 openings 2, 3, 4 and 2a, 3a, 4a all open FRÄNKISCHE profi-air technical data
19 Technical data sheet profi-air iso pipe 2 Iso pipe as a completely insulated and vapour-tight pipe made of extremely light-weight EPP including an iso pipe coupling for quick and easy connection. Profi-air iso pipes are suited for external, exhaust, supply and extraction air. The elements are push-fit, the iso pipe can be cut to custom length. Admissible operating temperature: -25 to 8 C Heat conduction:.42w/mk D 2 D 1 D 3 D 2 D 1 D 3 n completely insulated vapour-tight pipe system n easy and quick installation 1 n standard diameter DN 16 / DN 18 allows for connecting devices to the element without using adaptors n low weight profi-air iso pipe with coupling D 1 D 2 D 3 1 / 2 mm mm mm mm kg/pc. pc Iso pipe DN 16 x 1mm / 8 EPP Iso pipe DN 18 x 1mm / 8 EPP FRÄNKISCHE profi-air technical data 19
20 Technical data sheet profi-air iso pipe 9 bend 1 2 Iso pipe bend as a completely insulated and vapour-tight pipe made of extremely light-weight EPP including iso pipe coupling for quick and easy connections. Profi-air iso pipes are suited for external, exhaust, supply and extraction air. All elements are push-fit, the iso pripe bend can be divided into 2 x 45. Admissible operating temperature: -25 to 8 C Heat conduction:.42w/mk D 2 D 1 D 3 D 1 D 2 D 3 n completely insulated vapour-tight pipe system n easy and quick installation n standard diameter DN 16 / DN 18 allows for connecting devices to the element without using adaptors n low weight profi-air iso pipe 9 bend with coupling D 1 D 2 D 3 1 / 2 mm mm mm mm kg/pc. pc Iso pipe 9 bend DN / 8 EPP Iso pipe 9 bend DN / 8 EPP FRÄNKISCHE profi-air technical data
21 Technical data sheet profi-air exterior wall grill External wall grill made of stainless steel to be installed in walls with pipe connection, including fastening material. Can be used for incoming outside air or outgoing air. Easy fastening thanks to integrated drill holes in the grill frame. H DN n exterior wall grill, made entirely of stainless steel n standard diameter, no adpator necessary B profi-air exterior wall grill W H DN mm mm mm kg/pc. pc DN 16 max. 3m 3 /h stainless steel DN 18 max. 4m 3 /h stainless steel FRÄNKISCHE profi-air technical data 21
22 Technical data sheet profi-air roof hood 2 D 1 D 2 Roof hood as a completely insulated and vapour-tight roof lead-through with pipe connection, including connection element. Can be used for incoming outside air or outgoing air. Easy installation with the respective profi-air flat-roof lead-through or profi-air lead pan for different roof inclinations. 1 n completely insulated roof leadthrough element n including connecting material between roof hood and iso pipe D 3 3 DN profi-air roof hood, insulated 1 / 2 / 3 D 1 / D 2 / D 3 DN mm mm kg/pc. pc DN 16 max. 3m 3 /h 14 / 365 / / 219 / 2 16 steel DN 18 max. 4m 3 /h 14 / 365 / / 219 / 2 18 steel / FRÄNKISCHE profi-air technical data
23 Technical data sheet profi-air extract air poppet valve Position s (mm) Extract air poppet valve made of metal, including fitting frame to be installed in any profi-air tunnel and profi-air classic air valve DN 125. Suited for wall and ceiling installations. Regulating device to individually and progressively set the amount of air. T 1 D D 1 D 2 T 1 T T 2 profi-air extract air poppet valve Including fitting frame D / D 1 / D 2 T / T 1 / T 2 mm mm kg/pc. pc DN / 124 / / 18 / 5 white steel Position s [mm] db(a) ΔP t [Pa] db(a) 3 db(a) q v [m 3 /h] FRÄNKISCHE profi-air technical data 23
24 Technical data sheet profi-air supply air poppet valve Position s (mm) Supply air poppet valve made of metal, including fitting frame to be installed in any profi-air tunnel and profi-air classic air valve DN 125. Suited for wall and ceiling installations. Regulating device to individually and progressively set the amount of air. D D 1 D 2 n pre-installed sector plate for any valve n sector plate can be uninstalled easily T 1 T T 2 profi-air supply poppet valve Including fitting frame D / D 1 / D 2 T / T 1 / T 2 mm mm kg/pc. pc DN / 124 / / 18 / 5 white steel.55 1 without Sector plate with Sector plate ΔP t [Pa] Position s [mm].2 (m) db(a) 3 db(a) 25 db(a) ΔP t [Pa] Position s [mm].2 (m) db(a) 3 db(a) 25 db(a) p1a p1a q v [l/s] q v [l/s] q v [m 3 /h] q v [m 3 /h] 24 FRÄNKISCHE profi-air technical data
25 Technical data sheet profi-air supply/extract air poppet valve Supply or extract air poppet valve made of metal, including fitting frame to be installed in any profi-air tunnel and profi-air classic air valve DN 125. Suited for wall and ceiling installations. Regulating device to individually and progressively set the amount of air. D T 1 T profi-air supply/extract air poppet valve D T / T 1 mm mm kg/pc. pc DN / 18 PP white.14 1 Supply air Extraction air q s [m 3 /h] q e [m 3 /h] a = a = ΔP t [Pa] A db(a) ΔP t [Pa] A db(a) q s [l/s] q e [l/s] FRÄNKISCHE profi-air technical data 25
26 Technical data sheet profi-air supply/extract air wall passage H Wall passage for supply or extract air, made of stainless steel, to be used in any profi-air tunnel and profi-air classic air valve DN 125, inlcuding expanded metal filter insert and fastening material. Suited for wall installations. D i W profi-air wall air valve W H D i mm mm mm mm kg/pc. pc DN 125 supply/extract air white steel Without filter Regulator 1% open With pure filter Regulator 1% open With pure filter Regulator 5% open 26 FRÄNKISCHE profi-air technical data
27 Technical data sheet profi-air ventilation grill - supply/extract air Ventilation grill for supply or extract air, made of stainless steel, including fastening clamps, to be used in profiair tunnel 9 air valve for covering grills. Suited for floor and wall installations. H W 1 H 1 n flexible use in walls and floors n fastening in the exhaust box by using clamps, no screws needed n crush-resistant thanks to integrated braces n hygienic individual packing W profi-air ventilation grill Supply/extraction W / W 1 H / H 1 mm mm kg/pc. pc x 13mm 345 / / 8 stainless steel x 13mm 345 / / 8 white steel FRÄNKISCHE profi-air technical data 27
28 Notes 4.6 Brandschutz FRÄNKISCHE profi-air technical data 28
29 Rooted in Königsberg globally successful! Our facilities in Europe: Königsberg, Germany (headquarters) Bückeburg, Germay Schwarzheide, Germany Okrisky, Czech Republic St.-eonards-on-Sea, UK Moscow, Russia Yeles/Toledo, Spain Rebstein, Switzerland Torcy-le-Grand, France Ebersbach/Fils, Germany Hermsdorf, Germany Our facilities in Asia: Anting/Shanghai, China Pune, India Our facilities in Africa: Ben Arous, Tunesia Our facilities in North America and Mexico: Anderson, USA Guanajuato, Mexico FRÄNKISCHE is an innovative, growth oriented, medium-sized family-owned enterprise and industry leader in the design, manufacturing and marketing of technically superior corrugated pipe systems for drainage, electrical, building technology and industrial applications. We currently employ about 2,2 people worldwide. Both our many years of experience and expertise in plastics processing, our consulting services and the large array of products are highly valued by our customers. FRÄNKISCHE is a third generation family owned business that was established in 196 and is now run by Otto Kirchner. Today, we are globally represented with production facilities and sales offices. The proximity to our customers enables us to develop products and solutions that are perfectly tailored to our customers needs. Our action and business philosophy focus on our customers and their needs and requirements for our products. FRÄNKISCHE Your partner for sophisticated and technologically advanced solutions. Fränkische Rohrwerke Gebr. Kirchner GmbH & Co. KG Königsberg/Germany Tel Fax info.gb_h@fraenkische.de E.2235/ HT Subject to change without notice Cat. no
104 Chamber System Ostendorf. Ostendorf. Chamber System ISO RV-Systém OSMA
104 Chamber System Ostendorf Ostendorf Chamber System ISO 9001 RV-Systém OSMA Ostendorf Chamber System 105 Ostendorf Chamber System The Ostendorf Chamber System is multifunctional enough to offer suitable
More informationCost effective. Smooth. Reliable. LOG Internal Hole Gripper
LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications
More informationGAS SYSTEM HYDRA GS. The gas installation system that sets new standards. Witzenmann GmbH
GAS SYSTEM The gas installation system that sets new standards. Witzenmann GmbH Östliche Karl-Friedrich-Str. 134 75175 Pforzheim, Germany Phone +49 7231 581-0 Fax +49 7231 581-820 wi@witzenmann.com www.witzenmann.com
More informationSystem 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9
British Manufacturing since 1986 Contents Page About Us 4 System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7 System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9 System 150: 180 x 95mm
More informationINNOVATIVE & COMPLETE GAS SUPPLY SYSTEM FOR MEDICAL AND HOSPITAL APPLICATIONS
INNOVATIVE & COMPLETE GAS SUPPLY SYSTEM FOR MEDICAL AND HOSPITAL APPLICATIONS ALPI-LINE THE ADAPTED SOLUTION FOR MEDICAL GAS SUPPLY IN HOSPITALS Ceodeux Meditec is the medical range of the Rotarex Group
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48
More informationConnecting hoses. Type FS. Connecting hoses for the water-side connection of air- water systems and decentralised ventilation units PD FS 1
X X testregistrierung Connecting hoses Type G½" external thread and flat seal G½" union nut and flat seal Connecting hoses for the water-side connection of air- water systems and decentralised ventilation
More informationInstructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO
Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5
More informationSit to Stand Umbilical Solutions
Sit to Stand Umbilical Solutions Professional Cable Management New New New New Cable-Snake Cube Easy-Connect E-MAG, E-MAG-2B New New New New Cable-Snake Cube MX Easy-Outlet Easy-Desk-3G, Easy-Steel Easy-Floor
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationFlexible & Intelligent
Flexible & Intelligent The flexible copper tube cuprotherm CTX tubes are copper tubes with a firmly adherent coating. Due to their structure they can be easily processed and are characterized by a flexibility
More informationDräger PAS AirPack 1 Compressed Air Breathing Apparatus
Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing
More informationAir distribution systems Circular displacement outlet with adjustable damper VA-ZD...
Air distribution systems Circular displacement outlet with adjustable damper VA-ZD... DS 059 E 05.010/1 Construction design and function Preliminary remarks Displacement air outlets enable to extract pollutants
More informationTHE ULTIMATE IN MODULAR SYSTEM DESIGN
ROOFSAFE ANCHOR AND CABLE SYSTEM THE ULTIMATE IN MODULAR SYSTEM DESIGN FLEXIBLE COST-EFFECTIVE VERSATILE THE ULTIMATE IN FALL PROTECTION Product BROCHURE ROOFSAFE ANCHOR AND CABLE SYSTEM MEETING THE NEEDS
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationBall valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany
Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free
More informationAdjustable swirl diffuser ODZA TECHNICAL DATA
Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high
More informationAutomatic extractor outlet
L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions
More informationCOMPACT NITROGEN DIE SYSTEMS
COMPACT NITROGEN DIE SYSTEMS CONTENTSENTS 3 2 Compact Die Systems Fundamentals 3 Spring rates and scales 45 Standard cylinders Type CDS (3.3 100 kn) 6 Pad mounted cylinders Type CDSP (3.3 200 kn) 7 Low
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationAutomatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN
Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationFloat operated valve TYPE (SWDS)
Float operated valve TYPE (SWDS) Assembly and Operating Instructions for all models Float operated valve Type SWDS Assembly and Operating Instructions Rev.0 Page 1 of 12 Table of Contents 1 General 3 2
More informationMOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)
MOBILAIR M 235 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min (640 825 cfm) www.kaeser.com MOBILAIR M 235 Efficient and durable The powerful combination of the
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationSTAP. Differential pressure controller DN 15-50
Differential pressure controller 15-50 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE is a high-performing differential pressure controller that keeps the
More informationUpgradable balancing valves USV
Upgradable balancing valves USV Application / Description USV-I USV-M USV valves are designed for manual hydronic balancing of heating and cooling systems. USV-I (red knob) is used together with USV-M
More information1000/13.02 KOBSERT. Thread inserts for metals
1000/13.02 KOBSERT Thread inserts for metals Contents KOBSERT Thread inserts for metals Page The principle 3 The benefits 3 Product types 3 Applications in the Automotive and General industry 4 Technical
More informationMOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS
COMPRESSORS MOBILAIR M 210 / M 235 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min (640 825 cfm) www.kaeser.com MOBILAIR M 210 / M 235 The powerful combination of
More informationActuator HON 670 / 671
Actuator HON 670 / 67 Product information serving the gas industry worldwide Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationDI-DRO ADVANCED FORMING SYSTEMS
DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured
More informationTHE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT
THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT SPORTS INDUSTRY & SAFETY 2 THE NEW SP SERIES BAUER KOMPRESSOREN BAUER KOMPRESSOREN THE NEW SP SERIES 3 JOINT INNOVATION THE CONCEPT BEHIND THE NEW SP
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationWALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468
Hull Picture Art.. (pipe) or combination Splash guard Stream resistance * Wind tolerance Temperature level of mounting surface Size and hight (mm) Sealable WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467,,
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationViega Advantix Vario. Millimetre precision. Unlimited flexibility.
Viega Advantix Vario Millimetre precision. Unlimited flexibility. Viega Advantix Vario Individuality in its most beautiful form. Demanding design and high-quality materials have long since been par for
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationTB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options
TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance
More informationSelf-operated Pressure Regulators Type Universal Pressure Reducing Valve
Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve JIS version Application Pressure regulators for set points from 5 to 2800 kpa/0.05 to 28 bar Valve sizes ½B/15A to 4B/100A
More informationSERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER
Man500e 09/2006 Installation Operation and Maintenance Instructions SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER INDEX 1. INSTALLATION 2. COMPRESSED AIR SUPPLY 3. FLOW MEASURE
More informationCalculation tables for thermal expansion.
Calculation tables for thermal expansion www.sanha.com 2 Contents Subject Page 1 THERMALLY INDUCED CHANGES IN LENGTH 5 1.1 Thermal expansion 6 1.1.1 NiroSan -, NiroSan -ECO system pipes and copper pipes
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationGAS PRESSURE CONTROL UNIT TYPE 132
GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant
More informationFlat roof drainage 1
Flat roof drainage 1 F Ü R D I E ZU K U N FT G E DAC HT. alwitra waterproofing system Flat roof drainage systems are part of the proven alwitra waterproofing system. This system comprises: 1 Waterproofing
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationSERIES A24 RAISED RIB
SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance
More informationCompressed Air Conditioning Catalog Chapter I
Compressed Air Conditioning Catalog Chapter I 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened
More informationSmooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More informationATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1
ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar
More informationCHILLED BEAM FLEXICOOL IQID
CHILLED BEAM FLEXICOOL IQID TECHNICAL CATALOGUE 2 Flexicool IQID Chilled beam - Technical catalogue CHILLED BEAM FLEXICOOL IQID The chilled beam Flexicool IQID is an integrated system for ventilation,
More informationDifferential pressure controller (PN 16) AVPL return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AVPL return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family
More informationPressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More informationDräger OCEANUS 140 Mobile Compressor
Dräger OCEANUS 140 Mobile Compressor The Dräger OCEANUS 140 mobile compressor is designed for operations at sea. Tank Filling tube with filling valve Exhaust Safety valve Air filter Filter system P21 Petrol
More informationKLINGER CONAXE Double Offset High Performance Butterfly Valve DN
KLINGER CONAXE Double Offset High Performance Butterfly Valve DN 50-1300 www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has
More informationELEGANT AND SECURE MODERN BICYCLE PARKING SYSTEMS
ELEGANT AND SECURE MODERN BICYCLE PARKING SYSTEMS MOBILE ROOM SYSTEMS I SHELTER SYSTEMS I BICYCLE PARKING SYSTEMS I INFORMATION SYSTEMS SPACE SAVING WITH STYLE Clever ideas for order and a secure stand
More informationBERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.
Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction
More informationT208VR Series Tank Blanketing Vacuum Regulator
February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease
More informationINDUSTRIAL HOSE REEL suitable also for out-door workplaces. Made in Italy
technology, functionality, safety FLUIDS AND LUBRICATION EQUIPMENT in painted steel or in AISI 304 stainless steel ABS shock proof drum Made in Italy INDUSTRIAL HOSE REEL suitable also for out-door workplaces
More informationCasing Spacer Technology Leaders
Casing Spacer Technology Leaders Benefit today. Save down the line. www.racispacers.com NORTH AMERICA Why Raci Raci has been the global leader in casing spacer technology since 1952. Our uniquely designed,
More informationVibration isolation system 1VIS10W. User manual
Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.
More informationPiloted Non-Return Valves
ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product
More informationDifferential pressure controller (PN 16) AVPL - return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family
More informationAutomatic balancing valves
Automatic balancing valves ASV DN 15-50 (4th gen.) ASV-PV ASV-BD ASV-M DN 15-50 DN 15-50 DN 15-50 Description ASV whiteboard animation ASV valves are automatic balancing valves. Together with Danfoss presetting
More informationWorkshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only by using
More informationBIO GAS STORAGE TANKS. for each Plant Design. Long service life. Maintenance free set-up. Permanently gas-tight. Quickly installed
Long service life Maintenance free set-up BIO GAS STORAGE TANKS for each Plant Design Permanently gas-tight Quickly installed High operational reliability Suitable for heavy wind and snow loads Volume
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationTA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control
TA-Modulator Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control IMI TA / Control valves / TA-Modulator TA-Modulator The
More informationTHE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT
THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT SPORTS INDUSTRY & SAFETY 2 THE NEW SP SERIES BAUER KOMPRESSOREN JOINT INNOVATION THE CONCEPT BEHIND THE NEW SP SERIES PISTON AND AIR END COMBINED IN
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More informationSTAD. Balancing valves DN (MD60, MD61, MD62)
STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited
More informationGas Cylinder Cabinets
The fire resistant Maximum safety. Temperature increase of less than 50 K on the cylinder after 90 minutes according to EN 14470-2. G90 EN 14470-2 90 minutes max. 50 k increase of temperature FIRE CHAMBER
More informationCOMPACT NITROGEN DIE SYSTEMS
COMPACT NITROGEN DIE SYSTEMS CONTENTSENTS 3 2 Compact Die Systems Fundamentals 3 Spring rates and scales 45 Standard cylinders Type CDS (3.3 100 kn) 6 Pad mounted cylinders Type CDSP (3.3 200 kn) 7 Low
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationRapidmain Installation Guide
Rapidmain Installation Guide Aluminium Compressed Air Pipe Work Installation Guide Trafalgar Court, Waterloo Ind Estate, Widnes Cheshire. UK. Ref: Rapidmain installation guide 4b Index 1. Rapidmain fittings:
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationSupratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY
OXYFLEX - M T 2 3 5 / M T 3 0 0 M E M B R A N E D I S C D I F F U S ER UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION TECHNOLOGY von-drais-straße 7 D-55469 Simmern / Hunsrück Tel.: +49 6761
More informationDraw-wire system SZG165
Draw-wire system SZG165 www.wachendorff-automation.com Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions
More informationVibration isolated tables. Individually tailored to your requirements.
68 Vibration isolated tables Individually tailored to your requirements. LTH laboratory table Particularly robust and resistant n Adjustable leveling mounts n Rigid, welded steel subframe n BiAir membrane
More informationDifferential Pressure Control Valve (DPCV)
Differential Pressure Control Valve (DPCV) PATENTED Technical Data and Installation Instructions Page 1 V2 The modulating valves ART 241 balance and control the differential pressure (DPCV) automatically
More informationerc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany
Compart Umwelttechnik GmbH erc-o 2 -tech Ò innovative gas systems Markwerbener Str. 24 06667 Weißenfels Germany Phone: 0049 (0) 3443/2901-0 Fax: 0049 (0) 3443/2901-12 Mail: compart-weissenfels@t-online.de
More informationAVP-F. p setting range (bar) Code No. 003H6200
Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator
More informationBelt strength. Available the belt. (kg/m) PP - Polypropylene 2, to [B] PE - Polyethylene 1, to [B]
SERIES E20 FLAT TOP Eurobelt Series E20 Flat Top, due to a closed surface configuration, is the suitable conveyor belt for those applications in which it is not necessary any drainage through the belt
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationCable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.
Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationValves. Diaphragm shut-off valves, kidney-type
Valves Diaphragm shut-off valves, kidney-type Application When leakage of even the smallest quantities must be avoided with certainty For maximum requirements to operating safety For maximum requirements
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More information1305 Series Pressure Reducing Regulators
Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,
More information