CRYO. SuperVariTemp Magnet Inserts
|
|
- Carmel Hamilton
- 6 years ago
- Views:
Transcription
1 SuperVariTemp Magnet Inserts
2 Cryo Industries Sample in Vapor Variable Temperature Inserts (VTIs) fit into the bore of superconducting magnets and provide variable temperatures from <1.4 to 300 K. Samples are cooled by insertion into flowing helium gas exiting from the vaporizer (also known as the diffuser or heat exchanger). A small amount of liquid helium is drawn from the magnet s bath into the vaporizer located at the bottom of the sample tube. The liquid helium is vaporized and heated to your pre-selected temperature. The gas enters the sample zone and the sample is cooled to temperature of the flowing gas. Systems are available with choice of many standard sample tube sizes from 0.50 to greater than 4 or more inches. Inserts can be ordered to fit your existing magnet systems. The Super Variable Temperature (SVT) Inserts are available in three styles: Separate (top-loading) Insert Magnet Support Combo: variable temperature and magnet support. Combination Insert: Dynamic SuperVariTemp Insert and removeable Static Exchange Gas Insert: Two Inserts in One! All styles feature top-loading samples and high refrigeration capacity. All systems can be configured with vapor sheilding for extended high temperature operation. Helium-3 inserts are also available which install directly into or interchange with the VTI. Cryo Industries is able to offer the SuperVariTemp Magnet Insert alone or as part of a complete Superconducting Magnet System, that includes: High performance dewar SuperVariTemp Insert Standard Solenoids from 5 T to 17 T Liquid Helium Level Probe with electronic readout Integrated Superconducting Magnet Power System Temperature Sensors Temperature Controllers Superconducting Magnet System with Mossbauer, Magnetic Measurements, SuperVariTemp Magnet Insert Spectroscopy, Materials Research, Vibrating Sample Magnetometer, Scanning Tunneling Microscope or whatever your needs - CRYO has the capability to design and build superconducting magnet systems to meet your requirements.
3 LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. High Temperature Superconductor Testing High Current Leads Installed to Sample O.D O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) APPROX. O.D. CRUSHED INDIUM SEAL O.D (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT
4 SuperVariTemp Insert w/exchange Gas Insert LIFTING PROVISIONS (2) 10 PIN S ISO NW 40 SAFETY PRESSURE RELIEF SAFETY PRESSURE RELIEFS INSERT EVACUATION VALVE WITH NW 25 ISO NW DIA. 3-WAY EXCHANGE GAS VALVE (1) 10 PIN 5.50 (8) CLEARANCE HOLES FOR #10-32 SCREWS EQUALLY SPACED ON A 4.50 DIA. BOLT CIRCLE 4.00 (4) COPPER RADIATION BAFFLES WITH WIREWAYS 1.00 DIA. The exchange gas region is turbulent free and provides ultra stable temperatures. When the exchange gas insert is in use, helium vapor flows around (not in) the sample tube. The top-loading exchange gas insert easily removes for standard sample in vapor SuperVariTemp operation O.D O.D. (DYNAMIC FLOW SAMPLE TUBE) 1.00 O.D. AND COPPER (EXCHANGE GAS SAMPLE TUBE) APPROX. O.D. CRUSHED INDIUM SEAL O.D (OR GREATER) COPPER SAMPLE MOUNT WITH HEATER PROVISION FOR TEMPERATURE SENSOR AND (4) #4-40 TAPPED HOLES FOR FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH EXCHANGE GAS INSERT
5 SuperVariTemp Insert w/integral Magnet Support SAFETY QUENCH RELIEF WITH NW25 S (2) HIGH CURRENT LEADS (2) 10 PIN S SAFETY PRESSURE RELIEF 1.50 NOM. LADISH ISO NW (4) LIFTING PROVISIONS (1) 19 PIN INSERT EVACUATION VALVE WITH SAFETY PRESSURE RELIEF O.D. CUSTOMER SPECIFIED (1) 10 PIN HELIUM FILL WITH 3/8 QUICK CONNECT HELIUM VENT WITH 3/8 QUICK CONNECT 5.50 TOP BOLT CIRCLE CUSTOMER SPECIFIED (4) COPPER RADIATION BAFFLES WITH WIREWAYS BAFFLE O.D. CUSTOMER SPECIFIED (NOTE: O.D. OF BAFFLES ARE NORMALLY EQUAL TO OR LARGER THAN MAGNET O.D.) O.D. SAMPLE TUBE 1.50 O.D. Magnet Support and SuperVariTemp Insert Combo - single integral unit! O.D. MAGNET SUP RODS CRUSHED INDIUM SEAL 1.50 (RECOMENDED) 0.47 APPROX O.D. OUTER MAGNET TAIL MAGNET LENGTH TBD TOP OF MAGNET TO FIELD CENTER TBD 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND COPPER SAMPLE MOUNT WITH 50 OHM HEATER, PROVISION FOR TEMPERATURE SENSOR AND #4-40 TAPPED HOLES FOR SAMPLE MOUNTING PROPRIETARY INFORMATION TITLE: MAGNET INSERT WITH INTEGRAL MAGNET SUP
6 SuperVariTemp Insert w/pita Shielding (2) 10 PIN S 10 PIN (8).209 DIAMETER CLEARANCE HOLES FOR M5 SCREWS EQ. SP. ON A 5.71" DIA. B.C. SAFETY PRESSURE RELIEF ISO NW-50 EVACUATION VALVE WITH SAFETY PRESSURE RELIEF AND ISO NW-25 ISO NW O.D FLOW VALVE OPERATOR (4) M5 TAPPED HOLES FOR LIFTING AS SHOWN ON A 5.71" DIA. B.C (4) RADIATION BAFFLES O.D. O.D. (SAMPLE TUBE) INTERMEDIATE RADIATION SHIELD When insert is run at higher temperatures, Intermediate Radiation Shielding decreases amount of heat that escapes into the helium bath, resulting in reduced helium boil off O.D. O.D COPPER SAMPLE MOUNT WITH HEATER, PROVISION FOR TEMPERATURE SENSORS AND (8) #4-40 HOLES FOR SAMPLE MOUNTING HEATER, PROVISION FOR TEMPERATURE SENSORS AND 6.25 O.D. PROPRIETARY INFORMATION TITLE: MAGNET INSERT
Variable Temperature Storage Dewar Mount Inserts
Variable Temperature Storage Dewar Mount Inserts All inserts are available for either Liquid Helium or Liquid Nitrogen Dewars! DStat - External cryostat with insert leg DStatMag - Super Conducting Magnet
More informationCRYO INDUSTRIES. Liquid Helium Research Dewars
Liquid Helium Research Dewars Liquid Helium Research Dewars Cryo Industries Liquid Helium Research Dewars are finely designed and manufactured using the highest quality materials. A Liquid Helium reservoir
More informationRC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats
RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats www.cryoindustries.com INDUSTRIES RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats Designed
More informationMicroscopy Cryogenic WORKSTATION. Performance by Design
CRYO Microscopy Cryogenic WORKSTATION Optical cryostat for use in microscopy and spectroscopy Performance by Design RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, excellent temperature
More informationJANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS
OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS INTRODUCTION The Janis Research Company's Superconducting Magnet/Cryostat System is one of the most versatile tools available to the scientist
More informationSPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM
SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM Prepared by:- Magnex Scientific Limited The Magnet Technology Centre 6 Mead Road Oxford Industrial Park Yarnton, Oxford OX5 1QU, UK
More informationattoliquid Liquid Research Cryostats
WITTENSTEIN Group WITTENSTEIN Group 2018, attocube systems AG - Germany. attocube systems and the logo are trademarks of attocube systems AG. Registered and/or otherwise protected in various countries
More informationMagnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017
Magnet and RF Cavity Test Stand Design, SLAC Outline Test dewars and test stands Saturated bath test dewars Double bath test dewars SRF test cryostats SRF cryomodule test stands Horizontal magnet test
More informationCurrent Leads for Cryogenic Systems
Current Leads for Cryogenic Systems American Magnetics Inc. s (AMI) Vapor Cooled Current Leads provide reliable and consistent electrical current transfer from room temperature (300K) to a Liquid Helium
More informationBaffles and Traps Cryotrap
Baffles and Traps 362-6 Cryotrap Varian Low-Profile Water-Cooled Baffles combine 100% optical density with high conductance and unusually low overall height. They are especially useful in applications
More informationSuperconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)
Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS) Sensitivity: 1x10 11 A m 2 Applied DC fields: 0 T to 5 T Applied AC fields: 0 G to 3 G (zero-to-peak), 0.01 Hz to 1000 Hz Temperatures
More informationTable of Contents Want full page pictures with most important parts labeled in the beginning.
1 Table of Contents Want full page pictures with most important parts labeled in the beginning. Precool Procedures (Perform before cooling down): 1. Check N2 and 4He gas tanks to be sure that there is
More informationLiquid Helium Bath Cryostat
Liquid Helium Bath Cryostat Operating Manual Model TK1865M CONTENTS First A Word of Warning Lifting and Handling the Cryostat Using Cryogens Introduction The liquid helium cryostat. Type TK1865M Serial
More informationFirst Experimental Data of the Cryogenic Safety Test Facility PICARD
First Experimental Data of the Cryogenic Safety Test Facility PICARD C. Heidt, A. Henriques, M. Stamm and S. Grohmann 26 th International Cryogenic Engineering Conference 2016 in New Delhi, India KIT,
More informationProduct Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.
Product Report Solon, Ohio 44139 U.S.A. Page 1 of 7 TITLE Fugitive and Seat Leakage Performance Type of Swagelok VB05 Block and Bleed Process Interface Valves Witnessed by a Third Party PRODUCT TESTED
More informationHeliox TM. He systems to suit all applications
Heliox TM He systems to suit all applications heliox eliox Which Heliox is right for you? When choosing a Heliox system, there are technical parameters that you need to consider in order to achieve the
More informationHigh Pressure Equipment Pressure Vessels and Reactors Index
Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard
More informationProcedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1
Project: Novel Electron Bubble Particle Detector Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat Version 5.1 (Using side filling line) Hand Processed Changes HPC No. Date
More informationPressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
More informationVacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation
Cryogenics Vacuum Dry Turbo Pumping Stations Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators Hermetically Sealed Pumps for He3 Recirculation Oils, Filters and Traps Valves, Fittings and Adaptors
More informationfrom Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010
from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010 Dewar vessel noun. A container with an evacuated space between two walls, capable of maintaining its contents at a
More informationAn Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler
An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler Mahesh N 1, S A Mohan Krishna 2 1 PG Student, Vidyavardhaka College of Engineering, Mysore,
More informationStorage and transfer of cryofluids
Storage and transfer of cryofluids Christian Gianese Guilty 1: Arsène d Arsonval (1851-1940) He invented a glass container with double wall, the vacuum being done in the space between the outer and inner
More informationCryogenics of SRF Spoke Cavity Development at SMTF
Cryogenics of SRF Spoke Cavity Development at SMTF Michael White SRF Development Technical Division Fermi National Accelerator Laboratory May 11, 2006 Overview of Topics SMTF Overview CTF Cryogen Supply
More informationAN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER
P P P International Journal of Scientific Engineering and Applied Science (IJSEAS) - Volume-1, Issue-6, September 2015 AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON
More informationRHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.
RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge
More informationHelium-Liquefaction by Cryocooler for High-Field Magnet Cooling
Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling Y.S. Choi 1,,.A. Painter 3, D.L. Kim, B.S. Lee, H.S. Yang, H.W. Weijers 3, G.E. Miller 3 and J.R. Miller 3 1. KBSI-NHMFL Collaboration Center
More informationCalculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.
Beamex Calibration White Paper info@beamex.com Calculating Total Uncertainty of Temperature Calibration with a Dry Block World-class calibration solutions Calculating Total Uncertainty of Temperature Calibration
More informationShort Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.
Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV
More informationBIMA cryogenics (Dick Plambeck, 18jan2007)
BIMA cryogenics (Dick Plambeck, 18jan2007) Normal operation. Monitor from the antennas > 6-meter > receivers multiple> cryo rtd page. Troubleshooting. sensor what is it? normal range stage1 outer dewar
More informationPilot Assembly Replacement Manual Parts Needed: Phillips head screwdriver #2 Two Adjustable Crescent Wrenches Replacement Pilot Assembly
Pilot Assembly Replacement Manual Parts Needed: Phillips head screwdriver #2 Two Adjustable Crescent Wrenches Replacement Pilot Assembly Nexgrill Industries Inc. 800-913-8999 customerservice@grillservices.com
More informationAscend Aeon. User Manual. Innovation with Integrity. Version NMR
500 89 Ascend Aeon User Manual Version 00 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
More informationResidual Gas Analysis Systems for Industry
HIDEN RC SYSTEMS QUADRUPOLE MASS SPECTROMETERS FOR RGA, GAS ANALYSIS AND PROCESS MONITORING The HAL RC systems are designed for RGA, gas analysis and process monitoring applications including leak detection,
More informationTransition your department towards more productive helium-free MR operations 1
BlueSeal magnet BlueSeal magnet Transition your department towards more productive helium-free MR operations 1 Based on a decade of innovation, Philips BlueSeal is a fully sealed magnet designed to simplify
More informationAscend. User Manual. Innovation with Integrity. Version NMR
400 54 Ascend User Manual Version 04 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
More informationAscend DNP. User Manual. Innovation with Integrity. Version NMR
300 154 Ascend DNP User Manual Version 01 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationThanks for choosing EJAI SOLAR product
SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2
More informationDean Pump Self-Priming Chemical Process Pumps
Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL
More informationHigh Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units
High Va High Vacuum Pumps COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units 2 Leybold Full Line Catalog 2018 - High Vacuum Pumps leybold Contents High Vacuum Pumps Turbomolecular Pumps TURBOVAC
More informationDetector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane
Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,
More informationValves. Controllers. Valves Two Types
Hydraulics Taking the Irritation out of Irrigation My plants are getting irrigated, so I m all set, right? Marcus Duck Academic Advisor, Instructor & Program Coordinator MSU s 2-year Horticulture Programs
More informationHeliox Sorption Pumped 3 He Refrigerator Systems
Heliox Sorption Pumped 3 He Refrigerator Systems Principles of Operation and Control October 14, 2013 1 Contents 1 Introduction 4 1.1 Properties of 3 He................................ 4 1.2 Sorption Pumped
More informationCryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.
CRYOGENICS SAFETY Introduction Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases. The gases which are most widely used in industry and research
More informationL 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions
L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6
More informationPump out insert (condenser and still lines) overnight with turbo pump
Running the Dilution Fridge Before starting a run: Pump out insert (condenser and still lines) overnight with turbo pump Make sure LN and LHe traps are clean pump out with He4 rotary pump Start He3 rotary
More informationOxford Instruments Austin, Inc.
User's User s Manual Issue 01 / March 2013 / OIAI Cryo-Plex 10 Oxford Instruments Austin, Inc. Issue 01 / March 2013 / Original Instructions Oxford Instruments Austin, Inc. is a wholly-owned subsidiary
More informationThe Helium Leak Detector
The Helium Leak Detector Helium Leak Detector Main Components The main components of a helium leak detector are: 1. The analyzed, which enables to separate the tracer gas from other gases inside leak detector.
More informationVacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No
Rev. ECO Description Checked Approval Date 01 32- Release M. Smith Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System Dwg. No. 32-06003.05 Revision 01 June 18, 2007 1 1. Introduction 1.1.
More informationNational Accelerator Laboratory
Fermi National Accelerator Laboratory FERMILAB-Conf-97/268 A 1400 Liter 1.8K Test Facility T.J. Peterson, R.J. Rabehl and C.D. Sylvester Fermi National Accelerator Laboratory P.O. Box 500, Batavia, Illinois
More informationDesign of a Solid Wall Transonic Wind Tunnel
Design of a Solid Wall Transonic Wind Tunnel David Wall * Auburn University, Auburn, Alabama, 36849 A solid wall transonic wind tunnel was designed with optical access from three sides to allow for flow
More informationALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD
Operating Manual ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD 50 und ALU-CD 60 KGW - ISOTHERM Gablonzer Straße 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com
More informationSHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1
SHMS Dan Young Ext 5255 Downstream Beamline Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) 1/26/2015 1 10 14.5 SHMS Beam Line Large SHMS/HMS Angles (Configuration-1) SHMS minimum
More informationSprocket Selection Guidelines
Sprocket Selection Guidelines Table 1 Information Necessary to Order Sprockets 1. Chain Size Number, type, or drawing number of the chain to be used on the sprocket. (The suitability of a sprocket depends
More informationChange Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.
http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Three-way Changeover Valve Change Valve Changeover Air Direction by 90 Lightweight and Compact Design. Fine Operability and
More informationREPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID
PART REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID 0203 WHL 0250 WHL WHEEL HUB 0251 WHL AXLE 0252 WHL DUST CAPS 0253 WHL TIRE - 210 SP 0204 WHL 0211 WHL TIRE & WHEEL - SP 0250
More informationSafety in Cryogenic Operations at RHIC *
Safety in Cryogenic Operations at RHIC * Anthony Nicoletti, Dewey Lederle, Ahmed Sidi-Yehklef, Tom Tallerico, Roberto Than, Joe Tuozzolo Collider-Accelerator Department Brookhaven National Laboratory Upton,
More information(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure
This type of tube fitting comes in eight lengths to suit your applications. The tube fitting, provided with a hexagonal hole, can be easily installed using an Allen wrench, even in a narrow or limited
More informationThermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.
Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1 Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationOperating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100
Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100 KGW - ISOTHERM Gablonzer Str. 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com
More informationEXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics Large Hadron Collider Project LHC Project Report 388 EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC
More informationEXERCISE 2: THE VACUUM SYSTEM
EXERCISE 2: THE VACUUM SYSTEM Because vacuum system techniques are important to all of experimental physics, every undergraduate student should have had some experience in them. This exercise ensures that
More informationWater. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912
Water VAG DUOJET Automatic Air Valve Single-chamber type Product characteristics and benefits Resilient seated With flange end acc. to EN 1092-2 Single chamber air valve in compact design Very high discharge
More informationCryogenic System for a Large Superconducting Magnet in Space
4LL04 1 Cryogenic System for a Large Superconducting Magnet in Space Stephen M. Harrison, Erich Ettlinger, Gunter Kaiser, Bertrand Blau, Hans Hofer, Istvan L. Horvath, Samuel C. C. Ting, Jürgen Ulbricht
More informationA Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)
UN-GTR PART A INSERTION Stand 09.02.2011, 17:20 Uhr A.3.3 HYDROGEN STORAGE SYSTEM The hydrogen storage system consists of all components that form the primary pressure boundary of the stored hydrogen in
More informationAC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW
AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi
More informationParallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL!
Parallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL! This SOP describes the basic procedure for using the HEL Cat-24 parallel reactor,
More informationHighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off
Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar]
More informationFor use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY
For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest
More informationSeries Environmental Chambers
3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationCryomodule Maintenance Workshop Maintenance, Repair Strategies, and Fault Scenarios. J. Ozelis Senior SRF Coordinator
Cryomodule Maintenance Workshop Maintenance, Repair Strategies, and Fault Scenarios J. Ozelis Senior SRF Coordinator Outline for Discussions Maintenance - routine/preventative maintenance Schedules Specific
More informationInstalling a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assemblies
More informationUpdated: Variable Temperature
Updated: 2016-11-02 Variable Temperature Sample Preparation Make sure the probe is rated for the ultimate/final temperature Fully degas the sample, particularly if going to low temperature Be aware of
More informationDirectional Controls
Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................
More informationUHP - UHV APPLICATIONS
UHP - UHV APPLICATIONS High Performance Seals and Sealing Systems FOREWARD Today s sealing requirements for Ultra-High Purity and Ultra-High Vacuum are more demanding than ever before: Ultra-low Leak Rates
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationVacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01
INAOE. Tonantzintla, Mexico. 2010-06-23. June 23 rd, 2010 Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 Joel Molina INAOE Microelectronics Group jmolina@inaoep.mx 1 Vacuum
More informationFermilab MTF Cryogenic System & Vertical RF Cavity Test Facility. Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006
Fermilab MTF Cryogenic System & Vertical RF Cavity Test Facility Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006 1 Magnet Test Facility (MTF) Tevatron magnet test stands Testing temperature range
More informationOxygen Contamination
MPMS Application Note 1014-210 Oxygen Contamination This application note describes potential sources for oxygen contamination in the sample chamber and discusses its possible effects. Molecular oxygen,
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationWorld Area Differences Technical Information
World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National
More informationOrbital Motors Type OMP X and OMR X
Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2
More informationInsert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.
http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Protection Ring from Deformation Insert Ring 668 Protect tubes from deformation. Ultra soft tube is connectable to Fitting. Necessary for the connection
More informationASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.
90 O ELBOW LONG RADIUS Standard weight Extra strong Schedule 160 Double extra strong ASTM A-234 ASME / ANSI B16.9 Carbon and ferritic alloy steel Produced from X-rayed, stress-relieve welded pipe. Welds
More informationMASSIVE GAS INJECTION SYSTEMS FOR DISRUPTION MITIGATION ON THE DIII-D TOKAMAK
MASSIVE GAS INJECTION SYSTEMS FOR DISRUPTION MITIGATION ON THE DIII-D TOKAMAK T. C. Jernigan, L. A. Baylor, and S. K. Combs Oak Ridge National Laboratory D. A. Humphreys, P. B. Parks, and J. C. Wesley
More informationPrecision Liquid Settlement Array Manual
Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationOsborne Engineering Limited. OEJ Equalised thrust bearing internals
Osborne Engineering Limited OEJ Equalised thrust bearing internals General Description The Osborne Equalised J style thrust bearing assembly operates by generating and maintaining a substantial oil film
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More informationPROCESS MONITORING AND CONTROL
Chemical Engineering Process Design PROCESS MONITORING AND CONTROL Keith Marchildon David Mody Monitoring means Measurement 1. There is no Control without Monitoring 2. Monitoring should not be done without
More informationTo be published in the proceeding of ICEC-22, Seoul Korea, July 2008 MICE Note 231 1
270 mm o be published in the proceeding of ICEC-22, Seoul Korea, 21-25 July 2008 MICE Note 231 1 180 mm ests of Four P-415 Coolers Installed in the Drop-in Mode Green a, M. A., and Wang b, S.. a) Lawrence
More informationCoiling Tube with Twist-Proof Fitting
http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem
More informationGeneral Information Gravity roller conveyors are available in many sizes and configurations as shown on the following pages. There are many factors to consider when selecting a gravity conveyor. The following
More informationATOC Meteorological Tower (6 meter-4 level) Guide
ATOC Meteorological Tower (6 meter-4 level) Guide SETUP Outline 1. Siting 2. Components 3. Transportation 4. The Tower 5. The Cables and Data Logger Siting Selecting an appropriate site for the weather
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationSafety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow
Safety Aspects and Design of the Vent Isolation Chamber Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow 1. Scope This document addresses the safety aspects and design of the vent isolation chamber
More informationBruker Sample Transport
Bruker BioSpin Bruker Sample Transport BST Installation and Technical Manual Version 002 think forward NMR Spectroscopy Copyright by Bruker BioSpin NMR GmbH All rights reserved. No part of this publication
More information