THERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit
|
|
- Candice Bruce
- 6 years ago
- Views:
Transcription
1 THERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit Protection by intrinsic safety and by enclosures «i» and «t» For zone 0 (explosive atmospheres due to the presence of gas) For zone 20 (explosive atmospheres due to the presence of dust) Type B Operating manual /
2 Please read these Operating Instructions before commissioning the instrument. Keep the manual in a place that is accessible to all users at all times. Please assist us to improve these operating instructions, where necessary. Your comments will be appreciated. Phone : Fax : info.fr@jumo.net Service hotline : (0,337 /min) All necessary settings and possible adjustments inside the instrument are described in these operating instructions. If any problems should still arise during start-up, you are asked not to carry out any unauthorized manipulations on the unit. You could endanger your rights under the instrument warranty! Please contact the nearest subsidiary or the head office in such a case. 2
3 Contents Page 1 Introduction Use Special conditions for safe use Operating Conditions Description Designation Safety 6 2 Instrument identification Marking ATEX/IECEx Marking Marine 7 3 Mounting Dimensions Construction Capillary/Thermostatic element/thermowell General Thermowell Load limits of the protective sheaths depending on the diameters Opening of thermostat Fixing the thermostat Material of capillary and of bulb (probe) 11 4 Installation Regulation and notes Electrical connection Connection diagrams 13 5 Settings Adjusting the limit Conduct in case of failure 14 6 Specifications Switching function Electrical specifications Electrical connection to intrinsically safe, protection mode Ex «i» Use in explosive atmospheres due to the presence of dust 16 7 Maintenance 17 8 Appendix 18 EC type examination certificate EC declaration of conformity 20 Type approval certificate : BV IECEx Certificate
4 4
5 1 Introduction 1.1 Use Following execution, the thermostat with protection intrinsically safe «i» and protection by enclosure «t» type AMTXs-Ex can be used as : - TW Temperature controller - TB Temperature limiter It regulates and supervises thermal processes. Gas zone, they can only be connected to certified intrinsically safe equipment and which can be used in Zone 0, Zone 1 and Zone 2. Dust zone, protection mode "t" allows the use of material zones 20, 21 and 22. If this thermostat is used on a hazardous area, must be respected a provisions mounting and the functioning of devices in this type of area. The severing or buckling of capillary of thermostat with shaped mounting AMTXs-Exf (only capillary) cause permanent device failure! 1.2 Special conditions for safe use For storage and until mounting, the devices must remain in their original packaging in order to be protected from dust and other external attacks. They must be stored in a dry and clean environment. It s essential to put carefully the device in its original packaging. Storage temperature range : -50 et +50 C. Above or below these limits, the device could be damaged. The surface temperature must not exceed the value indicated on the product. Avoid falls and the locations where the material can undergo mechanical shock. Avoid vibrations, or by fixing the housing on a stable walled, or using a damper assembly (silents blocs ). The minimum radius of curvature of the capillary is of 5 mm. Avoid installation near sources of heat or excessive sunlight, to limit the effects of condensation night. 1.3 Operating conditions Position : indifferent Type : permanent Temperature range of housing : -40 C Temperature of utilisation of the thermostatic element with or without reinforcement : - Copper capillary and et copper bulb : -50 to +200 C - Copper capillary and stainless steel bulb : -50 to +300 C - Stainless steel capillary and stainless steel bulb : -50 to +300 C 5
6 1.5 Description These thermostats function on the principle of fluid expansion. The variation of temperature causes a variation of volume in the measuring system (consisting of a probe, and a capillary membrane) which acts on the switch by a transmission lever mechanical. 1.6 Designation EN (2009) / IEC (2011) EN (2007) / IEC (2011) EN (2009) / IEC (2008) 1.7 Safety In case of breaking of the measuring system, the filling liquid can escape. Currently, there is no restrictive statement from the health services in case of temporary emanation or low concentration, for example due to a breakage of the measuring system. Physical, and toxicological properties of the substances that may escape in case of failure of the measuring system Final scale value Hazardous reactions Risk of fire and explosion Ignition Explosive temperature limit C Vol. % Risk for water Irritant Toxicology Hazardous for health < +200 C C 0,6 8 V X X X C +350 C C - X X X - > 350 C C = no X = yes Toxic 6
7 2 Instrument identification 2.1 ATEX/IECEx marquing JUMO REGULATION METZ (1) Type: AMTXs-Ex (2) N of manufacturing.: (3) Years of manuf..: 2011 CE 0359 II 1GD (4) (5) Ex ia IIC T6 Ga (6) Ex t IIIC T80 C Da IP6X (7) -40 C < Tamb < C LCIE 11 ATEX 3039 X (8) IECEx LCIE X (9) Ui <= 30 Vdc; Ii <= 50mA; Pi <= 0,75 W, Ci = 0, Li = 0. (1) Address of the manufacturer (2) Sensor type (3) Serial number: Order number + position (4) Notified Body: 0359 = Intertek (5) Ex marking group and category (6) Ex marking for Gas zone (7) Ex marking for dust zone (IIIC conductive dust) (8) Number Ex Certification (9) Number IECEx Certificate of Conformity 2.2 Marine marking in option (BV) Type /25-01 Type Approval Certificate N : 32252/A0 BV AMTXs-Ex C 7
8 3 Mounting 3.1 Dimensions Thermowell version 8
9 Capillary exit version 9
10 3.2 Construction Epoxy coated aluminum case IP65 mini, or case stainless steel IP65 mini or case certificated ATEX «i», «t», complies with the standards EN (2009), EN (2007) and/or EN (2009). 3.3 Capillary/Thermostatic element/thermowell General Severing or buckling of capillary of thermostat for saillie mounting cause permanent device failure! The minimum allowable radius of curvature is 5 mm. The installation of the thermostatic element in JUMO thermowell is imperative otherwise the homologation of the thermostat mounting is no longer valid. The bulb must be completely immersed in the environment sample to avoid excessive variations of the contact point Thermowell For sheath, mounting, JUMO recommande a bolting torque : 80 Nm G 3/8 connection 140 Nm G ½ connection 180 Nm G ¾ connection Protective reinforcement steel, stainless steel, brass or nickel alloy. D 7 to 30 mm L 5 to 200 mm. Mounting Connection, Clamp, other next process If the thermowell is used as a passage of zone 1, the wall thickness must be greater than 1 mm. 10
11 3.3.3 Load limits of the protective sheaths depending on the diameters 3.4 Opening of thermostat - Unscrew the 4 cover screws - Remove cover with seal (not visible) Note: care must be taken to place correctly the seal during reassembly! 3.5 Fixing the thermostat - Using the template, drill the mounting holes - Attach the lower housing part with 4 screws 3.6 Material of capillary and of bulb (probe) End value of scale Up to 200 C Capillary Temperature probe Notes Copper (Cu) Ø 1,5 mm Num. Material Cu-DHP Copper (Cu) Num. Material Cu-DHP brazed Probe and capillary also achievable in AISI 316TI 11
12 4 Installation 4.1 Regulation and notes Please to respect, when making electrical connections in an explosive atmosphere, the requirements are : - The electrical connection must only be carried out by qualified personnel. - The choice of cable, for installation or electrical connection of the device, must respected regulation in force. - Connect the device to the ground terminal on the ground, with the protective conductor. The driver must have the same section as the supply line. Put the lines of grounded star, to a point of common connected to the supply voltage by the protective conductor. Do not loop the ground, that is to say not to them from one instrument to another. - Incorrect settings on the thermostat can affect the proper operation of the process or cause damage. That is why the adjustment should only be performed by qualified personnel. So please observe the relevant safety rules. - Accessories mounted on the walls of the shells such as cable glands, plugs fitted by you must be of a type certified or compatible with material certification. - A installation must verify that the hardware is suitable for operating conditions: degree of sealing envelopes. - In the case of particularly corrosive atmosphere, provide additional protection. Any operation is not performed in accordance with manufacturers instructions, it emerges from any responsibility. 4.2 Electrical connection - Prepare the cables using the appropriate tools. - Pass the connecting cable through the cable gland. - Make the connection according to the diagram engraved in the cover. - The cable must be installed in a fixed manner (cable gland tight on cable). 12
13 4.3 Connection diagrams 13
14 5 Settings 5.1 Adjusting the limit - Open the case. - Set the limit value with the setpoint button (5). 5.2 Comportement in case of failure Temperature controller: in case of failure of the measuring system (leakage), the electrical circuit is open. 6 Specifications 6.1 Switching function Temperature controller TW If the temperature at the probe exceeds the setpoint, the transmission mechanism actuates the microswitch which causes the opening or closing of the electrical circuit. When the temperature is again lower than the set point (less switching differential), the microswitch returns to its resting position. Temperature limiter TB When the temperature exceeds the setpoint, the electrical circuit is open and the microswitch is mechanically locked. When the temperature is lower than the set temperature less approximately 10% of calibrated span, it is possible to unlock manually after removal of the cover. 14
15 Setting ranges and characteristic of the probe Setting ranges/ thresholds C -20 à à à à à à à +200 Setting ranges/ thresholds C Switching differential % 1 2, , , , , , ,5 Switching differential % Max. probe temperature C Max. temperature of the probe C Max temperature of the case C Max temperature of the case C Probe length «L» in mm, Ø of the probe «d» in mm Material Cu Minimum length of the plunger (connection out) Ø 6 1) Ø 8 Probe Ø 6 Probe Ø Probe length «L» in mm, Ø of the probe «d» in mm Stainless material Minimum length of the plunger (connection out) -40 à +100 C Operating data Switching point accuracy in % of control range/limit value range Mid ambient temperature influence Admissible storage temperature Admissible ambient temperature for use Nominale position (NL) Switching differential 1 %, 2,5 % 5 % 7 % In the upper third of th escale or limit value ± 1,5 % ± 3 % ± 4 % Deviation of the ambient.temperature at the switching head and/or capillary from the 22 C calibration ambient temperature produces a switching point offset. Higher ambient temperatures = lower switching point Lower ambient temperature = higher switching point Switching difference in % 1/2,5 5 7 Ambient temperature influence on the switching head in %/K 0,15 0,26 0,34 Ambient temperature influence on the capillary in %/m 0,05<K<m 0,09<K<m -50 to +50 C -40 to C Any 6.2 Electrical specifications Ui < 30 V, li < 50 ma, Pi < 0,75 W, Ci = 0, Li = 0 Contacts or 15
16 6.3 Electrical connection to intrinsically safe, protection mode Ex «i» The equipment used in hazardous areas contains only intrinsically safe circuits. In a normal situation and in case of failure due to a short circuit, no flammable spark occurs or when devices do not heat at the surface beyond the class defined temperature (see also EN ). For an electric circuit can be defined as intrinsically safe must all devices that are in the circuit are designed with intrinsically safe and certified. Then check that the interconnection of intrinsically safe devices also meets the requirements of an electrical circuit intrinsically safe. Interconnection itself does not guarantee a intrinsically safe circuit. It must make a calculation of the intrinsic safety loop. To prove of intrinsic safety, electrical limits must conform to certificates for equipment. Conditions are verified by comparing the permissible limits of electrical equipment : Electrical equipment «i» Tension (U) Ui Cuurrent (I) li Power (W) Pi Inductance (mh) Li (+Lc câble) Capacity (µf) Ci (+Lc câble) Associated equipement Uo Io So Lo Co 6.4 Use in explosive atmospheres due to the presence of dust Consider the following values for use in explosive atmosphere due to the presence of dust: For all area : The surface temperature of the electronic equipment must not increase shall not increase so that the dust as cloud or layer, can be ignited. This is possible when the following conditions are respected : Dust as cloud For the prevention of inflammation of dust atmospheres, must limit the maximum temperature of the surface. It must be less than the lower of the two values whether 2/3 on the temperature auto-inflammation of dust cloud considered. Dust layer Surface on which it is not possible to avoid dangerous incandescent dust deposition, the surface temperature must not exceed the incandescent temperature under 75K. In case of upper layer to 5 mm, a reduction greater of the temperature is necessary. If the dust is present in both the cloud and the layer, as is often the case, the most unfavourable case. Remark : for the term we use area, the casing containing electrical equipment. 16
17 7 Maintenance Our thermostats require no operation of maintenance or repair In case of dysfunction, the device must be dismantled and send to our factory in order to be repaired or replaced. The degree of protection of the envelope must be permanently filled for this purpose, the packing seals must be maintained in good condition. Before working on equipment, must scrupulously follow the instructions on safety. Equipment for explosive atmospheres ATEX must be implemented only by qualified personnel in the field. 17
18 8 Appendix 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 JUMO GmbH & Co. KG Adresse : Moritz-Juchheim-Straße Fulda, Allemagne Adresse de livraison : Mackenrodtstraße Fulda, Allemagne Adresse postale : Fulda, Allemagne Téléphone : Télécopieur : mail@jumo.net Internet : JUMO Régulation SAS Actipôle Borny 7 rue des Drapiers B.P Metz Cedex 3, France Téléphone : Télécopieur : info.fr@jumo.net Internet : 28
ATH-EXx. B Operating Instructions
ATH-EXx Explosion-protected surface-mounted thermostat for potentially explosive gas atmosphere Zone 1 and potentially explosive dust atmosphere Zone 21 B 605051.0 Operating Instructions 2011-04-01/00379556
More informationNote: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-60 E-mail: mail@jumo.net Internet: www.jumo.net
More informationATH-EXx. B Operating Instructions
ATH-EXx Explosion-protected surface-mounted thermostat for potentially explosive gas atmosphere Zone 1 and potentially explosive dust atmosphere Zone 21 B 60.5051.0 Operating Instructions 05.08/00379556
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationRTD temperature probes
RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationAir Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery
More informationDK46 - DK800 Supplementary instructions
DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationTemperature gauge Installation Guide
Temperature gauge Installation Guide improper functioning, or damage. Additional information can be found at: CAUTION: Read this installation guide carefully before unpacking the temperature gauge. Improper
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationActuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationPressure control, differental pressure control and thermostat Type RT
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationType 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation
Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions
More information* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.
*09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationMechanical pressure switches
18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint
More informationSupplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC
Supplementary Installation and Operating Instructions Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex Category: II 2G Ex IIC II 3G Ex IIC Contents 1 General safety directions...3 2 Main safety features...4
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationVS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions
VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures
More informationPressure & Temperature Switches
Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase
More informationII 2G EEx ia IIC T6. Ignition protection class
ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationPart I - Installation
120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, F120; 820E, 822E UNITED ELECTRIC CONTROLS Installation
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More information1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS
1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationIA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom
Certificate Number: MASC MS/11-358X Issued: 22 September 2014 Expire: 22 September 2015 Page: 1 of 5 IA CERTIFICATE (Revision 3 Revised for Annual Review) IN TERMS OF REGULATION 21.17.2 OF THE MINERALS
More informationI/P Transducer Positioner Module
I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationAir Sensor. FCS Ex. Manual. AQ Elteknik AB
Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationBA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9
BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationArran LED Floodlight Luminaire
Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3
More informationTarget disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version
Target disk flowmeter Series DP Instructions manual DP65 DP500 R-MI-DP Rev.: 4 English version PREFACE Thank you for choosing the flowmeter series DP from Tecfluid S.A. This instruction manual allows the
More informationIA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)
Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional
More informationFlow controller Type ED/CCB311 Instruction manual
Flow measurement Flow controller Type ED/CCB311 1. GENERAL DESCRIPTION page 4 2. DETAILED DESCRIPTION page 4 3. PIPE - EXPLOITATION page 5 4. PREVENTIVE MAINTENANCE page 5 5. REPLACEMENT OF THE CONTACT
More informationINSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA
COMPACT PRESS. SWITCHES SERIES PCS & PCA WEATHERPROOF SERIES PCS SERIES PCA EXPLOSIONPROOF B B A A B = Cable entry A = Pressure connection WEIGHT 1kg dimensions in mm B = Cable entry A = Pressure connection
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K, H122P U N I T E D E L E C T R I C C O N T R O L S Installation and Maintenance Instructions
More information120 Series Explosion-Proof Pressure and Differential Pressure Switches
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationModel range*1) Switching pressure difference
Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationMounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6
Series 43 Temperature Regulators Type 43-5 and Type 43-7 Type 43-6 Type 43-6 Type 43-7 with flanged valve body, DN 32 to 50 Type 43-5 Type 43-7 with welding ends Mounting and Operating Instructions EB
More informationPressure maintenance valve SDV-P / SDV-P-E
Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted
More informationHafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range
Hafner-Pneumatik presents: Including Pneumatic Valves General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range General information - 1 A product that is supposed
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No
ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR
More informationType Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.
2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationOperating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry
Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationTechnical Data Sheet T 2025
Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationRTD Temperature sensor TH11
RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed
More informationInstruction Manual Contact Pressure Vacuum Gauge
MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More information