Heavy Duty Pocket Insets for the Oil & Gas Industry
|
|
- Marianna McLaughlin
- 6 years ago
- Views:
Transcription
1 ata sheet S/I N Rev. eavy uty Pocket Insets Spare connection heads, extensions and measuring insets for resistance thermometers and thermocouples Thermometers in this range have been designed for use with thermowells insertion allows for measuring element change without compromising the process Inbuilt technical features standardized design easily exchangeable during operation for insertion in thermowells of a wide range of design Large range of application chemistry petrochemistry process and power generation heating and ventilation engineering mechanical engineering
2 eavy uty Pocket Insets esign and Construction Mineral Insulated Cable (MIC) Compact filling between inner conductors and sheath with magnesium oxide powder which provides the sensor with high vibration resistance and flexibility as well as temperature loadability and electric insulation. Terminal lock Manufactured in ceramic with solder lugs for connecting the sensor, thus providing optimal contact for the low signal level. ase Plate Spring-loaded mounting of the base plate results in the measuring inset being pressed against the base of the thermowell, guaranteeing fast response times and reduction of resonance frequency as a result of bilateral fixing in the thermowell. Measuring lement The measuring element is fitted in a sleeve ensuring resistance to changes in temperature, with good heat transfer, and avoidance of resonance frequency. lso encapsulated against electrical, mechanical and corrosive influences by means of the metal sheath. S/I N Rev.
3 eavy uty Pocket Insets Connection eads Without isplay Without isplay With igital isplay Radial Mount GL luminium lloy poxy coating, 7µm GS stainless steel GL luminium lloy poxy coating, 7µm GS stainless steel poxy coating, 7µm GL luminium lloy GS stainless steel GLF luminium lloy poxy coating, 7µm GSF stainless steel UZ luminium lloy UZ luminium lloy KN luminium lloy KI Cast Iron Process xtensions Type WRM Sealing Ring Material: Nitrile Rubber S nipple & union x / in. NPT S nipple/union & oil seal x / in. NPT S nipple/union & spring x / in. NPT / in. SP M gland nut & ring / in. NPT S or S nipple / in. SP / in. NPT S or S nipple x / in. NPT S Gland nut & ring Mx / in. NPT Type WRM Sealing Ring Material: Nitrile Rubber Key = xtension length = xtension diameter 7S ex nipple & oil seal / in. SP / in. NPT S/I N Rev.
4 eavy uty Pocket Insets Ordering Information Code No. PRT eavy uty Temperature Inset/Connection ead Model No. V687/ X X X X X X X Inset Length U increment mm Inset Length U increment mm Inset Length U increment mm Inset Length U increment mm Sensor None x Pt, -wire sensor with sheath in stainless steel x Pt, -wire sensor with sheath in stainless steel x Pt, -wire sensor with sheath in stainless steel x Pt, -wire sensor with sheath in stainless steel x Pt, -wire sensor with sheath in stainless steel x Type K (Insulated ot Junction) sensor with sheath in stainless steel x Type K (Insulated ot Junction) sensor with sheath in stainless steel x Type K (Insulated ot Junction) sensor with sheath in Inconel x Type K (Insulated ot Junction) sensor with sheath in Inconel x Type J (Insulated ot Junction) sensor with sheath in stainless steel x Type J (Insulated ot Junction) sensor with sheath in stainless steel x Type T (Insulated ot Junction) sensor with sheath in stainless steel x Type T (Insulated ot Junction) sensor with sheath in stainless steel ccuracy No sensor Pt ohm, Class accuracy standard Pt ohm, Class accuracy specify range Thermocouple Class standard Thermocouple Class specify range Sensor iameter 6 mm standard mm (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) C F G S/I N Rev.
5 eavy uty Pocket Insets Code No. PRT PRT eavy uty Temperature Inset/Connection ead Model No. V687/ X X X X X X X X X X X X No inset fitted (Note ) ead Mounted Transmitters Without (Terminal lock fitted)... m Fixed Range Pt ohm only TR--co... m Fixed Range Pt ohm only TR--x (x ia Zone ) Programmable Range art Protocol &... m TT Programmable Range art Protocol &... m TT-x (x ia Zone ) Profibus P only (No indication) TF- Profibus P only (No indication) TF--x (x ia Zone ) Foundation Fieldbus only (No indication) TF- Foundation Fieldbus only (No indication) TF--x (x ia Zone ) Programmable Range art Protocol TT Programmable Range art Protocol TT-x (x ia Zone ) Fixed Transmitter Ranges No Transmitter Standard Fixed Range...6 ºC (... ºF) Standard Fixed Range... ºC (... ºF) Standard Fixed Range... ºC (... ºF) Standard Fixed Range...6 ºC (... ºF) Standard Fixed Range... ºC (... ºF) Standard Fixed Range... ºC (...8 ºF) Standard Fixed Range... ºC (... ºF) Standard Fixed Range... ºC (... ºF) Standard Fixed Range... ºC (...8 ºF) Standard Fixed Range... ºC (...7 ºF) Standard Fixed Range... ºC (...7 ºF) Standard Fixed Range...6 ºC (... ºF) Non-standard Range (Fixed) efault Factory Settings (Pt ohm,... ºC [... ºF] -wire) efined Flange (Specify from... to...) Certification x d x n x ia Safe Connection ead Not required UZ Connection ead in luminium lloy with M single cable entry IP6 UZ Connection ead in luminium lloy with M single cable entry IP6 KN Connection ead in luminium lloy with M single cable entry IP66 KI Connection ead in Cast Iron with single cable entry IP66 GL Connection ead in luminium lloy with single cable entry IP66 GL Connection ead in luminium lloy with single cable entry IP66 GLF (not with TF- transmitter) Radial mount Connection ead in luminium lloy with single cable entry IP66 with MI GLF (not with TF- transmitter) Radial mount Connection ead in luminium lloy with single cable entry IP66 with isplay GL (not with TF- transmitter) Radial mount Connection ead in luminium lloy with single cable entry IP66 with isplay GL (not with TF- transmitter) Radial mount Connection ead in luminium lloy with single cable entry IP66 with MI GS Connection ead in Stainless Steel with single cable entry IP66 GS Connection ead in Stainless Steel with single cable entry IP66 GSF (not with TF- transmitter) Radial mount Connection ead in Stainless Steel with single cable entry IP66 with MI GSF (not with TF- transmitter) Radial mount Connection ead in Stainless Steel with single cable entry IP66 with isplay GLS (not with TF- transmitter) Connection ead in Stainless Steel with single cable entry IP66 with isplay GLS (not with TF- transmitter) Connection ead in Stainless Steel with single cable entry IP66 with MI (Note 6) (Note 6) (Note 7) (Notes, ) (Note ) (Note ) (Notes, ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) (Note ) J K L M N P R C F G J K L M X O P N S C G V W K R L M Y Z N T S/I N Rev.
6 eavy uty Pocket Insets Code No. PRTS & PRT eavy uty Temperature Inset/Connection ead Model No. V687/ X X X X X X X X X X X X X X XX Cable ntry Thread/Glands Not required Standard (M x.) x M x. / in. NPT (by adaptor from M) x / in. NPT (by adaptor from M) Process ntry Connection ead (Note ) (Note ) Not required / in. SP Female Thread / in. NPT Female Thread M x. Female Thread (Note 6) xtension Type Not required S- Nipple & Union / in. NPT ead with / in. NPT Thermowell = mm stainless steel S- Nipple & Union (Oil seals fitted) / in. SP ead with / in. NPT Thermowell = mm stainless steel S Spring version / in. NPT ead with / in. NPT Thermowell = mm stainless steel S Nipple with locknut / in. SP ead with / in. NPT Thermowell = 7 mm stainless steel S Nipples with locknut / in. SP ead with / in. NPT Thermowell = mm stainless steel S Fabricated M x. head with / in. NPT Thermowell = mm stainless steel S Nipple with locknut / in. SP ead with / in. NPT Thermowell = mm stainless steel 7S exagon (Oil Seal fitted) / in. SP ead with / in. NPT Thermowell = mm stainless steel (Note 7) (Note 7) (Note ) C F J L M N T 6 S/I N Rev.
7 eavy uty Pocket Insets Notes.. Not available with Sensor code. Not available with Sensor code,,,,,,, C,,, F, G,. Not available with Sensor code,,, C,,, F, G,. Not available with Sensor code,,,,,. Not available with Sensor code, 6. Not available with Sensor code,, C,,, F, G, 7. Not available with ead Mounted Transmitter code,, 6, F,, J, K, L, M, N 8. Not available with ead Mounted Tranmitter code, 6, F,, J, K, L, M,N. Not available with ead Mounted Transmitter code,,. Not available with Sensor code,,,,,,, C,,, F, G,. Not available with ead Mounted Transmitter code,, 6,, K, M. Not available with Certification code. Not available with ead Mounted Transmitter code K, L. Not available with ead Mounted Transmitter code K, L, M, N. Not available with Connection ead code.,, C,, V, W, Y, Z 6. Not available with Connection code C, 7. Not available with Process ntry Connection ead code, C 8. Not available with Process ntry Connection ead code, C. Not available with Process ntry Connection ead code, S/I N Rev. 7
8 Contact us Limited Process utomation Salterbeck Trading state Workington, Cumbria C S UK Tel: + ()6 8 6 Fax: + () Inc. Process utomation. County Line Road Warminster P 87 US Tel: Fax: Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of. Copyright ll rights reserved KXTR S/I N Rev..
ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More information9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs
Data sheet DS/9408 EN Rev. M 9408 Series Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling design minimizes operational costs Low maintenance,
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems
ABB MEASUREMENT & ANALYTICS DATA SHEET 9408 series Dissolved oxygen systems Measurement made easy Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationEndura AZ40 Sensor assembly High temperature filter assembly kit
Instruction replacement procedure INS/ANAINST/026 EN Endura AZ40 Sensor assembly High temperature filter assembly kit Kit reference: AZ400-761, -771, -772 Measurement made easy 1 Introduction This publication
More informationFebruary Cable glands For general industry and hazardous areas
February 2017 Cable glands For general industry and hazardous areas Introduction When safety matters, there is only one choice The Nicote and Kopex range of cable glands come to ABB through the acquisition
More information9408 series Dissolved oxygen systems
ABB MEASUREMENT & ANALYTICS INSTRUCTION MANUAL IM/908 REV. K 908 series Dissolved oxygen systems Measurement made easy 908 series Dissolved oxygen systems Introduction The 908 Series dissolved oxygen system
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAA0000123 This is to certify: That the Pressure Transmitter with type designation(s) SITRANS P series DS III, P310, P410 Issued to Siemens AG - Process Industries
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationAP100 series ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS INSTRUCTION MANUAL IM/AP100 REV. D AP100 series ph/redox (ORP) cartridge sensors with water-wash option Measurement made easy AP100 series ph/redox (ORP) cartridge sensors For
More informationUKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide
ABB MEASUREMENT & ANALYTICS PRODUCT GUIDE PG/SMD140 EN REV. B UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide Measurement made easy UKAS calibration laboratory
More informationPositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible
Change from one to two columns Technical Information TI/EDP300_ED-EN Rev. A PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationRTD Temperature sensor TH11
RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationCLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction
www.clarksol.com LRK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe s, Rugged Molded PP onstruction DESRIPTION The series 200 vortex flow transmitters are designed with equipment
More informationFPD175 Compact orifice carrier assembly
ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION FPD175 Compact orifice carrier assembly The smart solution for remote applications. Measurement made easy Installation, commissioning and operating / maintenance
More informationEndura AZ40 Sensor assembly Smart electronics PCB
Instruction replacement procedure INS/ANAINST/023 EN Endura AZ40 Sensor assembly Smart electronics PCB Kit reference: AZ400-769 Measurement made easy 1 Introduction This publication details replacement
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationFlow Measurement SITRANS F C
Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationDTG - LCD Digital Temperature Gauge USER MANUAL
DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More information2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications
Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity
More informationLevel transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids
Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).
More informationS261 Remote seals with capillary tube
Contents Data Sheet SS/S261EN Rev. 0 S261 2600T Series Pressure Transmitters Engineered solutions for all applications Measurement made easy Wide range of remote seal types llows optimum design for each
More informationCable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.
Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationMicro Motion 7812 Fiscal Gas Density Meter
Product Data Sheet PS-001162, Rev. B April 2009 Micro Motion 7812 Fiscal Gas Density Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers
ABB measurement & analytics data sheet JAA, JAF and JAG Pneumatic indicating controllers 2 JA A, JAF an d JAG P N EUMATI C I ndicating cont rollers DS/JAx_DBT_DTE-EN Rev. H Measurement made easy Engineered
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationFlow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationPURA. Pure Gas Dewpoint Transmitter. Users Guide
PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter
More informationL (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:
Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II
More informationPlok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation
- Plok Rapid Mating Multi-Pin Industrial onnector mphenol Industrial Sine Systems * Pyle onnectors orporation eatures and enefits Rapid mate spring loaded, push to mate, pull to unmate coupling system
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationSEALED CONNECTORS FOR THE LIMIT SWITCHES
SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications
More informationCertificate of Conformity
Certificate of Conformity Certificate Holder: CCG Cable Terminations (PTY) LTD 33 37 Forge Road Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA Electrical Apparatus: A2F, A2FX, and A2FCG Cable
More informationUltrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN
Ultrasonic Continuous level measurement Overview Page 64 VEGASON series 60 Page 66 6 VEGASON Non-contact measurement with ultrasonics Measuring principle Short ultrasonic pulses in the range of 5 to 70
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationSeries 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use
Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationMeasurement & Analytics Wet gas monitoring
Product guide PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring Economical wet gas metering using non-proprietary correlations Measurement made easy Introduction With many of the most economically
More informationSmart performance with innovative and ever-strong coil drive even under harsh working environments
Smart Valve Positioner SS2 inear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationCable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories
able Glands RoHS ompliance Plastic & Metal able Glands dapters Reducers & Enlargers Grommets & ccessories L File #: E363825 cable gland is a device that allows the user to pass a cable, wire or tube into
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationService Calibration are you doing it properly?
ABB MEASUREMENT & ANALYTICS ARTICLE Service Calibration are you doing it properly? A variety of factors, including wear and tear and non-ideal installation conditions, can cause the performance of an instrument
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationTerminal Head Section User Guide
Example: Terminal Heads Terminal Head Section User Guide Ø100 105 Ø52 Process Conduit Entry Entry KNC 3/4 M20 x 1.5 4.25 5.53 62 34.5 IP6 200 o C Product Photograph 14 Technical Drawing (measurements in
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More information3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
More informationRR 16 Commercial & Industrial Regulator
RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate
More information1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG
A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationNivuBar Plus II
NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard
More informationL3 Pressure and Level transmitter
SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes
More informationHEAVY DUTY PNEUMATIC
HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More information44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES
WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø
More informationRadiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224
Detectors Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224 213 FIBERTRAC, SOLITRAC, MINITRAC, POINTRAC, WEIGHTRAC Radiation-based
More informationDiaphragm pressure switches, 42 V
0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationSanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.
Sanitary RTD Temperature sensor TH17 Compact Instructions Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. The single element RTD is specifi cally designed
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationY:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1
1.0 PIECE PARTS - parts listing 1 5311-0710 Nut 1 2 5443-2820 Hose Stem 1 3 6362-3950 O-Ring Seal 14.0x1.78 1 4 6414-2820 Strainer 1 5 6313-0030 Spring 2 6 5321-1980 Handhold 1 7 5066-2120 Cover 1 8 5363-1350
More informationINDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable
INDUSTRIAL Pressure Transmitters Product Guide Low cost to high accuracy portfolio Ranges from 70 mbar to 1400 bar Flexible, rugged and reliable Fixed and rangeable 4-20mA outputs Electrical/pressure connection
More informationMPM416W/WK/WRK Submersible Level Transmitter
/WK/WRK Submersible Level Transmitter /WK/WRK Submersible Level Transmitter Features Separate construction; full sealed stainless steel construction for submersible/inserted sensor; aluminum-alloy electric
More informationIP 69 Protection against water under pressure
44 he European echnical Standard DIN EN 50 262 Metric cable glands for electric installations - the end of the PG Cable glands threads. he technical standards Cable Glands for cables and conductors with
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More information