TF- & DM-Series. Turbine flowmeter

Size: px
Start display at page:

Download "TF- & DM-Series. Turbine flowmeter"

Transcription

1 Turbine flowmeter

2 Table of contents 1. General Safety guidelines Marking of important information General safety guidelines Description Design and measuring principle Technical data Pressure drop Dimensions Model numbering key Model numbering key TF- & DM-Series Model Numbering key Pickoff Installation / commissioning Flow meter Safety guidelines Checks after delivery Operating pressure, tightening torque Installation Piping Configuration Contamination / filter Commissioning Pickoff and amplifier Checking the signal pick-up Installation Connection of pickoff, amplifier, electronics Explosion protection (ATEX) Troubleshooting Maintenance Declaration of conformity Warranty Customer service TrigasDM GmbH

3 1. General Thank you for selecting a TrigasDM product for your flow measurement application. Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and gases. Made in Germany Our products are exclusively developed and manufactured in Neufahrn, 20 km north of Munich, ensuring world-class technical know-how for our customers. Contact We are proud of our high-quality products and friendly customer service and welcome you as a valued customer to our growing family. You can benefit from our long-standing experience and our comprehensive technical support. TrigasDM GmbH Tel.: Erdinger Str. 2b Fax: info@trigasdm.com Neufahrn, Germany This user manual contains information on the description, operation, commissioning and maintenance of the TrigasDM turbine flow meter. For special applications, repair or further information on this or other products, please contact TrigasDM directly. The manufacturer may modify this document without prior notice. Prior to use, request or enquire about valid documentation from the manufacturer if necessary. Warranty claims against the manufacturer may become void if invalid documentation is used. TrigasDM GmbH

4 2. Safety guidelines 2.1 Marking of important information Important information is specially highlighted in this user manual. CAUTION To avoid danger to persons, this information is marked with CAUTION. ATTENTION To avoid danger to equipment, this information is marked with ATTENTION. NOTE Special information for operation / commissioning and maintenance is marked with NOTE. 2.2 General safety guidelines Before using the TrigasDM flow meter, this user manual and all safety instructions must be carefully read in their entirety and understood. Take all necessary precautions to ensure the safety of personnel and equipment. These precautions include, but are NOT limited to, the following examples: Mechanical and electrical installations must only be carried out by qualified and authorized personnel. It must be ensured that the upper limit of the measuring range of the flow meter is not exceeded. Do not install measuring instruments and cables in the vicinity of strong magnetic sources, such as electrical cables, electric motors, transformers, welding equipment, relays or high-voltage cables. These sources can cause electrical noise, resulting in incorrect pulse signals. Flow meters which are designed for applications in liquids are not suitable for applications in gas. Applicable safety standards (for example the ones in accordance with the German Occupational Safety and Health Act) must be observed for the installation and/or operation of the flow meter. Non-observance can result in DANGER to personnel. A flow meter is a precision instrument. Do not use compressed air to clean the flow meter or check its function. TrigasDM GmbH

5 3. Description 3.1 Design and measuring principle Turbine flow meters are the ideal solution for measurement applications in liquids, where there is a requirement for high accuracy, very fast response times, compact design, high reliability in continuous operation and flow changes at fluctuating temperatures. The flow-sensitive element of this volumetric measuring instrument is a turbine rotor concentrically suspended on precision bearings. The flow of the medium imparts a rotational movement on the turbine wheel which is proportional to the velocity of the flowing fluid. The innovative helical design of the rotor blades guarantees improved linearity and reduced pressure loss. Because the flow passage is fixed, the rotation speed is also a real measure of the liquid volume flowing through the flow meter. The rotation of the turbine rotor generates electrical impulses in the Pickoff. Each of these impulses represents a minute and well defined volume of liquid. The turbine flow meter consists of 3 main components: Housing (1) Helical rotor & flow straightener (2) Pickoff with lock nut (3) TrigasDM GmbH

6 3.2 Technical data Flow range: Response time: see "Measuring ranges" table <3 ms Temperature range: TF-Series -270 C up to 150 C DM-Series -270 C up to 400 C Operating pressure: Viscosity: Calibration accuracy: Repeatability: Linearity: Standard material: up to 540 bar depending on connection AN: up to 540 bar HS: up to 34 bar Tri-Clamp: up to 50 bar Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. (Standard viscosity: 1.3 mm²/s) ±0.03% of reading ±0.05% of reading ±0.5% of reading value in the linear flow range ±0.1% with linearization electronics Stainless steel TrigasDM GmbH

7 3.2.1 Measuring ranges TF- & DM-Series Linear Range Extended Flowrange K-Faktor 1) max. Frequency 1) [l/min] [l/min] [Pulse/l] [Hz] RF 2) und Mag 3) RF 2) Mag 3) Alle Model min. max. min. min. max. DM2-8 0,5 4) 5 4) 0,05 0,8 5, TF/DM4-8 0, ,1 0, TF/DM6-8 1,9 20 0,2 0, TF/DM8-8 2,8 33 0,3 0, TF/DM-08 3,0 40 0,4 0, TF/DM-10 4,5 60 0,6 1, TF/DM-12 7,6 90 0,9 1, TF/DM ,2 3, TF/DM ,8 6, DM , DM DM ) The K-factors and frequency data are average values. Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. 2) RF = Frequency-modulated pickoff 3) Mag = Magnetic pickoff 4) DM2-8 ±2% of reading TrigasDM GmbH

8 3.2.2 Pressure drop Subsequently, the pressure losses at different flow rates are listed. TF- & DM-Serie Pressure drop [bar] % of the max. linear flow Model 10% 25% 40% 55% 70% 85% 100% DM2-8 0,00 0,01 0,03 0,05 0,08 0,11 0,15 TF/DM4-8 0,01 0,03 0,06 0,16 0,19 0,27 0,35 TF/DM6-8 0,01 0,02 0,06 0,11 0,16 0,23 0,32 TF/DM8-8 0,01 0,05 0,11 0,20 0,30 0,46 0,61 TF/DM-08 0,01 0,03 0,08 0,14 0,21 0,29 0,36 TF/DM-10 0,06 0,12 0,23 0,41 0,61 0,92 1,22 TF/DM-12 0,06 0,13 0,24 0,42 0,64 0,93 1,22 TF/DM-16 0,06 0,09 0,16 0,27 0,39 0,57 0,74 TF/DM-20 0,06 0,13 0,24 0,43 0,62 0,96 1,31 DM-24 0,07 0,16 0,32 0,60 0,89 1,32 1,74 DM-32 0,07 0,08 0,14 0,24 0,34 0,51 0,66 DM-40 0,03 0,06 0,13 0,21 0,40 0,45 0,61 TrigasDM GmbH

9 3.2.3 Dimensions TF- & DM-Series AN-Housing Inner Tube Ø Housing [mm] Connection Ø AN-Size Pickoff Model [mm] A B C ["] t [mm] Thread DM2-8 7,6 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7,7 TF/DM4-8 7,6 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7,7 TF/DM6-8 9,4 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7 TF/DM8-8 10,2 62,2 25 / 25 ¾ -16UNJF-3A 1/2 6,7 TF/DM-08 11,2 62,2 25 / 25 ¾ -16UNJF-3A 1/2 6,2 TF/DM-10 12,8 69,1 SW 36 7/8-14UNJF-3A 5/8 10,6 TF/DM-12 14,3 82,6 SW /16-12UNJ-3A 3/4 9,5 TF/DM-16 21,9 90,4 SW /16-12UNJ-3A 1 8,1 TF/DM-20 25,4 103 SW /8-12UNJ-3A 1 1/4 10,3 DM-24 33,4 116,6 SW /8-12UNJ-3A 1 1/2 8,9 DM-32 44,5 154,0 SW /2-12UNJ-3A 2 10,4 TF- & DM-Series HS-Gehäuse Inner Ø Housing [mm] Connection Pickoff Model [mm] A B C t [mm] Thread DM2-8 7,6 62,2 22 / 17 9,5 7,2 TF/DM4-8 7,6 62,2 22 / 17 9,5 7,2 TF/DM6-8 9,4 62,2 25 / 25 12,7 6,6 TF/DM8-8 10,2 62,2 25 / 25 12,7 6,2 TF/DM-08 11,2 62,2 25 / 25 12,7 5,7 TF/DM-10 12,8 69,1 26 / 22 15,9 10,1 TFDM-12 14,3 82,6 26 / 22 19,1 7,0 TF/DM-16 21,9 90,4 33 / 25 25,4 5,7 TF/DM-20 25,4 103,0 43 / 27 31,8 10,4 DM-24 33,4 116,6 50 / 24 38,1 8,9 DM-32 44,5 154,0 63 / 24 50,8 10,4 DM-40 59,7 128,0 Ø 85 64,0 8,1 The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth (t). DM-Serie 5/8-18UNF-2B DM-Serie 5/8-18UNF-2B TF-Serie 11/16-24NEF-2B TF-Serie11/16-24NEF-2B TrigasDM GmbH

10 3.3 Model numbering key The type number describes the properties of the measuring instrument Model numbering key TF- & DM-Series (f.e. DM-16AN-BC-1-S) DM -16 AN -BC -1 -S Configuration -S = Standard -L = Lightweight construction -K = Lightweight short version Construction Material -1 = Stainless Steel Bearing -BA = Ball Bearing, Standard -BC = Ball Bearing, Ceramic End Fitting AN = AN thread connection HS = Hose Barb NE = NPT thread connection T1 = Tri-Clamp ½ ¾ T2 = Tri-Clamp 1" - 1 ½ T3 = Tri-Clamp 2 T4 = Tri-Clamp 2 1/2" Base Model 2-8 = iø 7,6 mm 4-8 = iø 7,6 mm 6-8 = iø 9,4 mm 8-8 = iø 10,2 mm -08 = iø 11,2 mm -10 = iø 12,8 mm -12 = iø 14,3 mm -16 = iø 21,9 mm -20 = iø 25,4 mm -24 = iø 33,4 mm -32 = iø 44,5 mm -40 = iø 59,7 mm Model DM = DM-Series TF = TF-Series TrigasDM GmbH

11 3.3.2 Model numbering key Pickoff (f.e. R07C3T) R 01 C3 O Temperature Sensor T = Integrated in Pickoff 0 = without Connector C2 = MS Connector 2 Pins C3 = MS Connector 3 Pins C4 = MS Connector 4 Pins L1 = 1m cable outlet L3 = 3m cable outlet L5 = 5m cable outlet Thread 01 = 5/8-16, High Profile 02 = 5/8-16, Low Profile 03 = 5/8-16, High Profile, Explosion Proof 04 = 5/8-16, High Profile, High Temp. 06 = 11/16-24, High Profile 07 = 11/16-24, Low Profile 08 = 11/16-24, High Profile, Explosion Proof 09 = 11/16-24, High Profile, High Temp. Model R = Modulated Carrier (RF) M = Magnetic (Mag) L = Lysis SMART-RF A = Amplified (TTL) TrigasDM GmbH

12 4. Installation / commissioning 4.1 Flow meter Safety guidelines Mechanical and electrical installations must only be carried out by qualified and authorized personnel. The maximum measuring range of the flow meter must not be exceeded. The flow meter operates under pressure. Only carry out work on the flow meter when it is depressurised. If toxic, explosive or other dangerous liquids are used, they must be drained off into a safe area. The system must be completely drained and rinsed before commencing work. The metals utilised in construction are slightly porous at a microscopic level, and traces of liquids that are used during calibration may be retained. The mixture of two relatively safe fluids can potentially lead to an unstable and unpredictable reaction, even in case of trace residues, which may remain in the pores. Establish the system pressure slowly during commissioning, to avoid possible damage to the rotor from over-speeding. Flow meters which are designed for applications in liquids are not suitable for applications in gas Checks after delivery Carefully unpack the flow meter and check for cleanliness (e.g. packaging residues). Check the condition of the flow meter and look for visible damage. Check the rotor for ease of movement. TrigasDM GmbH

13 4.1.3 Operating pressure, tightening torque TF- & DM-Series max.operating pressure Max.operating pressure [bar] Model AN HS DM TF/DM TF/DM TF/DM TFDM TF/DM TF/DM TF/DM TF/DM DM DM DM-40 N/A 34 TF- & DM-Series tightening torque Tightening torque [Nm] Aluminium pipe Steel pipe Modell Min. Max. Min. Max. DM TF/DM TF/DM TF/DM TFDM TF/DM TF/DM TF/DM TF/DM DM DM TrigasDM GmbH

14 4.1.4 Installation The flow meter must be installed according to the marking that indicates the direction of flow (on the housing). Turbine flow meters function correctly in any installation position. To optimize the accuracy of flow measurement at low flow rates, the flow meter should be installed in the same position in which it was calibrated. The default installation configuration for the flowmeter during calibration is horizontal with the pickoff in vertical position, pointing up Piping Configuration Turbine flow meters can be affected by the velocity profile of the fluid being measured. Installation with proper pipe runs will reduce or completely eliminate flow profile induced measurement errors during calibration and operation. Inlet section and outlet section, schematic diagram A straight run of pipe of at least 10 times the pipe diameter in an upstream direction, and 5 times the pipe diameter in a downstream direction are recommended (see figure and table). The upstream section should be fitted with flow straightening vane. Appropriate flow straightening sets (up- and downstream) are available on request. TrigasDM GmbH

15 Inner Ø Minimum lenght for Up- & Downstream [mm] Upstream Standard Downstream Standard Upstream Flowstraightener TrigasDM Downstream Flowstraightener TrigasDM Model DM2-8 7, TF/DM4-8 7, TF/DM6-8 9, TF/DM8-8 10, TFDM-08 11, TF/DM-10 12, TF/DM-12 14, TF/DM-16 21, TF/DM-20 25, DM-24 33, DM-32 44, DM-40 59, N/A N/A Longer straight sections may be required if there are devices that significantly disturb the volume flow upstream of the installation location of the flow meter. Pumps, valves, elbows, etc. may cause strong velocity profile distortions or swirl in the pipe making the installation of flow straighteners necessary. Connecting mating pipes and fittings to the housing of the flow meter should be implemented with appropriate supports, to avoid undue strain on the flow meter. The flow meter should not be exposed to excessive vibrations, as they have a negative impact on the precision of the measurements and may cause damage to the bearing. The inner diameters of the pipe connections and the turbine must be matched. If they cannot be identical, it is preferable that the inner diameter of the pipe connection is slightly smaller than the inner diameter of the turbine rather than the other way around. Flow metering sections must be designed in such a way as to prevent the introduction of pressure surges onto the flow meter. Pressure surges can cause the instrument to display a flow rate that is too high, and in extreme cases, can damage the flow meter. At the installation location of the flow meter, pressure surges must be kept below 10% of the current flow rate. Control valves should be installed downstream of the flow meter. Opening a valve upstream of the flowmeter when the meter section is drained can result in a hard impact of the liquid striking the rotor (Water Hammer), possibly resulting in damage to the rotor. This can also have a negative effect on calibration. Installing a bypass section parallel to the flow meter makes it possible to clean the pipe when a measuring instrument is installed, or to repair or replace the flow meter without interrupting system operation. TrigasDM GmbH

16 Liquid flow meters should be installed so that liquid remains in the area of the flow meter when flow in the system is interrupted Contamination / filter All pipe sections and components in the metering line must be cleaned prior to the installation of the flow meter. Pipe Sealants, metal shavings and slag can damage the flow meter. If the cleanliness of the fluid cannot be guaranteed, a filter should be installed upstream of the flow meter, subject to the diameter of the flow meter. Model Inner Ø [mm] Filter mesh width DM2-8 7,6 10 Mikrometer TF/DM4-8 7,6 10 Mikrometer TF/DM6-8 9,4 10 Mikrometer TF/DM8-8 10,2 10 Mikrometer TFDM-08 11,2 10 Mikrometer TF/DM-10 12,8 10 Mikrometer TF/DM-12 14,3 10 Mikrometer TF/DM-16 21,9 20 Mikrometer TF/DM-20 25,4 20 Mikrometer DM-24 34,4 50 Mikrometer DM-32 44,5 50 Mikrometer DM-40 59,8 50 Mikrometer TrigasDM GmbH

17 4.1.7 Commissioning ATTENTION Increase the pressure slowly during commissioning, to avoid possible damage to the rotor from over-speeding. ATTENTION Avoid dry running! Liquid flow meters must not remain in pipes in the system that have been partially or completely emptied. This may lead to corrosion and damage to the bearings. The type of measuring fluid, the bearing type used in the flow meter, and the period during which the metering section is decommissioned and therefore dry, can reduce the service life and negatively affect the operation of the flow meter. If it is economically viable and possible in the specific operating conditions, the flow meter should be always removed from the line, cleaned and stored, if there is any doubt about the level of the liquid in the pipe during the decommissioning period. TrigasDM GmbH

18 4.2 Pickoff and amplifier CAUTION Mechanical and electrical installations must only be carried out by qualified and authorized personnel. NOTE The standard pickoff is an R01C20 with a two-pin MS connector. A wide variety of pickoffs are available, with customer-specific connectors. Please contact TrigasDM for a detailed consultation Checking the signal pick-up Measure the resistance between pin A and pin B: 1. Target value for magnetic measuring element: 2200 Ohm +/-10%, 2. Target value for modulated carrier frequency (RF) measuring elements: 10 Ohm +/-15%, 3. Resistance between each pin and housing: >1 MOhm at 500 V. If one of these values is outside the tolerance, the pickoff must be replaced Installation ATTENTION Tighten the pickoff manually without using force, to prevent the housing from being deformed. 1. Hand-tighten the Pickoff Do not use tools. 2. Tighten the lock nut securely. 3. The measuring element is removed from the housing by loosening the lock nut. TrigasDM GmbH

19 4.2.3 Connection of pickoff, amplifier, electronics The pickoff produces a relatively weak output signal. An amplifier is required to convert the signals from the measuring element into a signal that is suitable for evaluation electronics. In addition, a flow computer or similar signal receiver is required to convert the flow meter signals into a visual display on a display, or to provide control signals. TrigasDM offers a complete range of electronic devices for flow meters. Do not install measuring instruments and cables in the vicinity of strong magnetic sources, such as electrical cables, electric motors, transformers, welding equipment, relays or high-voltage cables. These sources can cause electrical noise, resulting in incorrect pulse signals. A shielded cable (preferably with braided shielding) must be used for the connections between pickoff, amplifier, electronics and display instrument. The amplifier should be installed as close as possible to the flowmeter pickoff. Pickoff cables may not be installed together with other cables (no shared cable protection). A ground cable with a cross-section of 2.5 mm² (see #14 AWG or larger diameter) between the amplifier ground and measuring element housing or the cable protection can reduce electrical noise. A ground connection with the amplifier ground can also reduce electrical noise. ATTENTION The cable shield may only be grounded in accordance with the operating manual of the electronics used Explosion protection (ATEX) Pickoffs and electronics can be supplied in explosion proof versions (ATEX) on request. With explosion proof electronics, TrigasDM turbine flow meters can be used in environments as severe as Ex-Zone 1. TrigasDM GmbH

20 4.3 Troubleshooting The following Steps for error detection or error correction can be taken if the turbine emits no signal or a faulty signal: Check the power supply of the electronics Turbine check for proper operation and true running. If necessary, clean the turbine. Check Pickoff (see Chap ): RF Pickoff: 10 Ohm ± 15% Magnetic Pickoff: 2200 Ohm ± 10% More details and values for other Pickoffs are available on demand. Check wiring. Check cable shield. 5. Maintenance The TrigasDM turbine flow meters do not require any user performed maintenance. Depending on, e.g.: Type, System design, Environmental or operating conditions, Measuring liquid and Age, these flow meters need to be periodically recalibrated and if damaged, repaired or replaced. NOTE Independent consulting and calibration as well as repair services are available through TrigasFI. TrigasFI maintains a flow calibration laboratory which is certified to the highest ISO levels and maintains traceability to German and other international standards. Calibration history is maintained for all flowmeters and which forms the basis for the determination of customer-specific and application-specific recalibration intervals. ATTENTION A flow meter is a precision instrument. Do not use compressed air to clean the flow meter or check its function. TrigasDM GmbH

21 6. Declaration of conformity TrigasDM flow meters are not subject to the WEEE directive and comply with the RoHS directive. TrigasDM flow meters comply with the valid EU directives (EU Declaration of Conformity). 7. Warranty TrigasDM GmbH (supplier) guarantees that all the equipment supplied hereunder is flawless with regard to materials and workmanship, provided that the equipment was selected in accordance with its intended purpose, installed properly and not operated incorrectly. Only the current "General Terms and Conditions" of TrigasDM apply. You can either request a copy of the terms and conditions by calling , or visit our website at for information. 8. Customer service If you should require customer service for your TrigasDM products, please contact our customer service department. All requests for information concerning a specific flowmeter must include the model and serial number of the measuring instrument. We will provide you with all possible assistance over the phone. If your equipment has to be examined or repaired at our plant, whether within the warranty period or after its expiration, our customer service department will issue an authorisation number, which is used to initiate our quick and efficient customer service processing. On receipt at our plant, your equipment will be repaired or replaced without delay, calibrated and returned to you within the shortest period possible. Please do not return any products without an authorisation number. TrigasDM GmbH Tel.: Erdinger Str. 2b Fax: info@trigasdm.com Neufahrn, Germany TrigasDM GmbH

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Gas Applications Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because

More information

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Gas Applications Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because

More information

Flow metering in gases Introduction to COMBIMASS family

Flow metering in gases Introduction to COMBIMASS family Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,

More information

KOBOLD KSM FLOWMETER. User Instructions

KOBOLD KSM FLOWMETER. User Instructions KOBOLD KSM FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSM_manual_08-10 Table

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

Turbine Flowmeters for Liquid Applications

Turbine Flowmeters for Liquid Applications Turbine Flowmeters for Liquid Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

Turbine Flowmeters for Gas Applications (Metric)

Turbine Flowmeters for Gas Applications (Metric) Turbine Flowmeters for Gas pplications (Metric) Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs.

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media www.kem-kueppers.com Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001 9001 2

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes. Centrifugal Gas Separator ZGA Operating Manual Am Neuen Rheinhafen 4 - D-67346 Speyer Postfach 1709 - D-67327 Speyer Phone: +49 (6232) 657-0 Fax: +49 (6232) 657-505 Internet: http://www.burmt.de Email:

More information

Turbine Flowmeters for Liquid Applications (Metric)

Turbine Flowmeters for Liquid Applications (Metric) Turbine Flowmeters for Liquid pplications (Metric) Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs.

More information

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids www.kem-kueppers.com Technical Datasheet ZHM ST Series Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Operating Instructions of BROSA tension load cells, types 0111, 0113

Operating Instructions of BROSA tension load cells, types 0111, 0113 Operating Instructions of BROSA tension load cells, types 0, 03. Description of BROSA tension load cells. Structure and function The BROSA type 0 and 03 tension load cells transmit and measure the tensile

More information

DTG - LCD Digital Temperature Gauge USER MANUAL

DTG - LCD Digital Temperature Gauge USER MANUAL DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

user leaflet GAUGING TRANSDUCERS

user leaflet GAUGING TRANSDUCERS user leaflet Solartron Metrology Gauging Transducers are high precision measurement probes intended for all gauging applications demanding high accuracy and a high degree of repeatability. The one piece

More information

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas Vortex Flow Meter Wafer or Flange Connection - Steam - Liquid - Gas Working Principle & Circuit Diagram Working Principle When a column body placed in flowing fluids in pipe, a series of vortices will

More information

Operating Instructions DB41

Operating Instructions DB41 PKP Process Instruments Inc. 10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax:

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

P900. P900, Datenblatt Seite 1 DESCRIPTION

P900. P900, Datenblatt Seite 1 DESCRIPTION , Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and

More information

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100 Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027 Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3

More information

NivuBar Plus II

NivuBar Plus II NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

SCHMIDT Flow Sensor SS Instructions for Use

SCHMIDT Flow Sensor SS Instructions for Use SCHMIDT Flow Sensor SS 25.60 Instructions for Use SCHMIDT Flow Sensor SS 25.60 Table of Contents 1 Important Information... 3 2 Safety instructions... 3 2.1 Use of oxygen (O 2 )... 3 2.2 Information concerning

More information

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions *09005184* BA_EN_ME11 Rev.B 09/15 *09005184* d e v e l o p i n g s o l u t i o n s ME11 Operating Manual Pressure Transmitter Table of Content 1 Safety Guidelines 2 Application Purpose 3 Description of

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A. Coriolis Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

DEUTSCH. Flüssigkeits- Mengenmesser FMO. Seite Flow Meter FMO. Page Compteur volumétrique. Page 43-63

DEUTSCH. Flüssigkeits- Mengenmesser FMO. Seite Flow Meter FMO. Page Compteur volumétrique. Page 43-63 Originalbetriebsanleitung Original main operating instructions Notice d instructions générale originale Flüssigkeits- Mengenmesser FMO Seite 2-22 Flow Meter FMO DEUTSCH Page 23-42 Compteur volumétrique

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp-, p- and T-Sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Gas Massflowmeter Venturi- and Probe Type Precise

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

DK48 - DK800. Quick Start. Variable area flowmeter

DK48 - DK800. Quick Start. Variable area flowmeter Quick Start Variable area flowmeter General safety notes You can find the newest and/or additional information in the handbook, the datasheet, special manuals, certificates and the download center at www.krohne.com.

More information

FPD20 Series. Gear wheel flow sensor

FPD20 Series. Gear wheel flow sensor . FPD20 Series Gear wheel flow sensor Series FPD20-2 - M-5455/0315 Series FPD20 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.2 Exclusion of

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TFS SERIES FLOW METERS. FAILURE

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

PRAHER PLC-MP AQUASTAR MANAUL 2009

PRAHER PLC-MP AQUASTAR MANAUL 2009 PRAHER PLC-MP AQUASTAR MANAUL 2009 1. Copyrights This Operating Manual contains copyright-protected information. All rights reserved to Praher Kunststofftechnik GmbH. This Operating Manual is designed

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version Target disk flowmeter Series DP Instructions manual DP65 DP500 R-MI-DP Rev.: 4 English version PREFACE Thank you for choosing the flowmeter series DP from Tecfluid S.A. This instruction manual allows the

More information

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter Malema Sensors M-2700 Integrated Ultrasonic Flow Meter Operating Instructions TABLE OF CONTENTS Introduction............... 3 Storage and Handling........... 4 Installation Instructions........... 4 Start

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Instruction Manual SB02, SB03, SB04 All metal flow limiter Instruction Manual SB02, SB03, SB04 All metal flow limiter PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden-Nordenstadt Tel.: ++49-(0)6122-7055-0 Fax: ++49-(0)6122-7055-50 Email: info@pkp.de

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC Supplementary Installation and Operating Instructions Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex Category: II 2G Ex IIC II 3G Ex IIC Contents 1 General safety directions...3 2 Main safety features...4

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR Operating instructions for variable area flow meter with needle valve Model: UVR/UTR 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument inspection... 3 4. Regulation use... 3 5. Operating principle...

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

PURA. Pure Gas Dewpoint Transmitter. Users Guide

PURA. Pure Gas Dewpoint Transmitter. Users Guide PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP or NPT, Socket Welding - 29 C + 425 C Max Pressure : 136 Bars (Class 800) Specifications : With draining

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

_ pressure transducers. User Manual

_ pressure transducers. User Manual _ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference! Z11.0.1X.6C-18 Mounting and Operating Manual Atmospheric Oxygen Sensor Element GOEL 370, GOEL 381 Please read these instructions carefully before use! Please consider the safety instructions! Please keep

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information