Continuous Oil Condition Monitoring
|
|
- Sophie Hudson
- 6 years ago
- Views:
Transcription
1 Continuous Oil Condition Monitoring LubCos H 2 O+ Lubrication Condition Sensor Application area Stationary screw-in sensor for the continuous determination of the oil condition in hydraulic and lubricating oils. Performance features Measurement and documentation of changes in hydraulic fluids and lubricants. Data is continuously documented and stored. In that way deterioration and changes in the oil (e.g. water inleakage, oil change,...) can be indicated. Through this, damage can be recognized or completely avoided at an early stage. This offers the opportunity to prevent machine failures as well as to prolong maintenance and oil change intervals by means of appropriate measures. Furthermore, by monitoring the lubricant, correctly performed maintenance work and the use of the required lubricant quality may be documented. LubCos H 2 O+ Design characteristics The sensor is provided with a ¾ thread and can be e.g. integrated in a return line or the tank. Optionally, with an integrated LED status indicator with 1 segments on the back side of the sensor which visualizes the oil condition. Sensor head LED status indicator The communication with the sensor takes place over a serial RS232 interface. Optionally, the signals are sent over two analog outputs (4...2 ma). In order to also enable a long-term record of data up to half a year, the sensor has a data storage unit which can be read out over the serial interface. Measuring principle The sensor records four different physical oil characteristics as well as its periodic change: Temperature, relative oil humidity and water activity, relative permittivity and conductivity of the fluid respectively. As especially the conductivity and the relative permittivity show a strong connection to the temperature, next to the characteristic values at current temperature the sensor also sends the data at reference temperature. Subject to change 4.6 1/2
2 Technical data / Example of use Example of use By using the sensor different changes of the oil condition can be detected. The following example shows a typical course of relative permittivity, conductivity and relative humidity during various changes of the condition in the system. By means of the characteristics, different oil types may be differed, oil refreshing and oil change can be detected and the relative humidity, free water as well as the deterioration and deterioration rate can be defined respectively. Relative permittivity ε at 4 ºC [-] Total acid number NZ [mg KOH /g oil ] Conductivity at 4 ºC [ps/m] Relative humidity r.h. [%] Conductivity G at 4 ºC [ps/m] 3,4 3,2 3, 2,8 2,6 2, Refill oil 1 5 l ε Refill oil 1 5 l Water penetration r.h. NZ Oil 1 11 l Oil change to Oil 2 11 l Time Oil 1 11 l Oil change to Oil 2 11 l Time Free water Drying 2, 1,6 1,2,8, Sensor data Size Unit Operating pressure Operating temperature Ambient conditions, operation: Temperature Humidity Ambient conditions, storing: Temperature Humidity Pressure fluids Wetted materials Sealing material Power supply Power input Output Power output (2x) Interface Optical indicator, optional Measuring range 1) rel. permittivity rel. humidity Conductivity Temperature Measuring resolution rel. permittivity rel. humidity Conductivity Temperature Measuring accuracy rel. permittivity 2) rel. humidity Conductivity Temperature 1) Additional display of temperature gradient and trend 2) Measured with n-pentan at 25 C Mineral and ester fluids (HLP, HEES) galvanized steel, FPM, polyurethane resin, epoxy resin NBR ,2 typ.,3 max RS232 1 segment LED *1-4,1,1,3 ±,15 ± 3 < 3 ±,3 bar C C % r.h. C % r.h. V A ma - % r.h. ps/m C - % r. H. ps/m K - % r. H. ps/m K Time G We produce fluid power solutions ARGO-HYTOS GMBH P.O. Box 116 D Kraichtal-Menzingen Phone Fax info.de@argo-hytos.com 2/2
3 Oil Diagnostic Systems Online and bottle measurement Mobile and stationary operation Lab quality accuracy
4 The new generation of oil diagnostics Mobile and stationary operation: Shop-air connector for laboratory measurement and gas bottle for field measurement Online and bottle measurement: Bottle adapter for batch sampling and minimess connector for online measurement 274
5 The new generation of oil diagnostics PODS Pro is the new generation of portable oil-diagnostic instruments for simple, quick and reliable monitoring of oil cleanliness. PODS Pro is based on many years of know how and represents the advanced version of PODS with newest technology. Many features were improved, thus PODS Pro is not only lighter than its predecessor, but also offers the classification according to SAE AS 459. Productive Online & Bottle sample analysis by one instrument. As before you can rely on PODS Pro even under severest operating conditions. The measurement results are reported simply, quickly and reliably. With PODS Pro you have the option to run online or bottle sample analysis with the same instrument. Profitable the PODS Pro Special: The all-inclusive delivery program includes a robust rollerbox with all necessary accessories. The ARGO-HYTOS software PODSWare sets new standards for service statistics and allows, for example, a detailed mapping of the machine life. Proving PODS Pro live We would be happy to show you PODS Pro live. Simply ask for a noncommittal demonstration. Rely on hightech oil diagnostic systems from ARGO-HYTOS. Certificate for measurements according to the different standards. These certificates can be issued with individual labels. 275
6 Advantages at a glance Online and bottle sample analysis With two turns of your hand, using the two fluid adapters in the allinclusive delivery, PODS Pro is converted from a "Monitor" to a "Lab analyzer". In the online mode PODS Pro is connected directly to the hydraulic circuit via Minimess tubing and allows specific and continuous monitoring of the oil cleanliness. 2. Flexibility Due to its lower weight PODS Pro can be easily carried to each location. For longer distance transport the rollerbox is used All-included delivery PODS Pro is supplied with a very robust rollerbox, which is air- and water tight and contains all necessary accessories such as gas cartridges, power adapter, fluid adapters for online and bottle mode, handpump for oil sampling as well as clean sample bottles. The box is lockable and can be used for safe shipping to the ARGO-HYTOS Service Center, for instance for calibration. 4. Pressure range up to 69 psi By direct measurement at system pressures up to 69 psi without bypassing, the risk of outgasing and bubble counting is drastically reduced. 5. High viscosity and high contamination PODS Pro can measure particle contamination up to code 24 according to ISO 446:1999. This is achieved by a sensor with a limit concentration of 9. particles/ml at 1% optical coincidence and avoids time consuming and complicated dilution procedures. Another important advantage is its ability to measure oils with a viscosity up to 394 SUS. 6. Variable flow rate PODS Pro automatically regulates the flow rate to an appropriate value between 15 and 5 ml/min, depending on the oil pressure and the viscosity. This feature makes it insensitive to variations in the hydraulic system during the measurement. 7. Controlled cleaning with ECOLINE The oil service filter unit ECOLINE cleans oils up to a selected cleanliness class with PODS Pro. For this purpose ECOLINE pumps the oil over a filter. At the same time PODS Pro measures the cleanliness of the oil in front of the filter online and turns off ECOLINE when the target cleanliness class is reached. The cleanliness class is documented on a printout. 276
7 Software PODSWare A powerful software! PODSWare as supplement to PODS Pro is a tool to record and evaluate the measured data in a comfortable manner. Apart from this PODS Pro may be completely controlled from the control window of the software. The PODSWare includes the following languages: German, English, French, Italian Starting and stopping measurements. Setting parameters and downloading stored data. Graphical tracking of online measurements by time graphics. Build-up of a data bank and linking of measurements to machines. Historic review of the oil cleanliness. Particle concentration-size distribution. Chronological review of the particle concentration. 277
8 Technical information Detection Sensitivity Size ranges Size channels Flow rate Light extinction complies with Japanese Industry Standard (JIS-B-9925:1997) 4 1 µm(c) (ISO-MTD); ~1-1 µm (ACFTD) 4 1 µm(c) (ISO-MTD); ~1-1 µm (ACFTD) 8 channels ISO-MTD sizes [µm (c)] ACFTD sizes [µm] ~1 2 ~5 1 ~15 25 ~ ml/min automatic regulation Calibration ISO-MTD in oil (ISO 11171:1999) Cleanliness classification ISO 446; NAS 1638; MIL-STD-1246C; NAVAIR 1-1A17, SAE AS 459 Cleanliness classes ISO 446 code 1 to 24 Concentration limit Measurement results Light source Counting efficiency Wetted materials Fluid pressure Temperature Relative humidity Viscosity Material compatibility Pressure medium Sample bottles System properties Operating modes Software (optional) Weight Dimensions 9. 1% optical coincidence Oil cleanliness classes (according to standard), concentration (particles/ml), viscosity (mm 2 /s, cst or SUS), temperature Laser diode By JIS-B-9925:1997 Stainless steel, sapphire, aluminium, Aflaz, PTFE psi F oil at 77 F ambient; F ambient; F housing 2 85% non-condensing, up to 98% when stored SUS particle counting with viscosity measurement, SUS particle counting only Mineral oils, Skydrol, environmentally compatible pressure fluids and phosphate esters CO 2 liquid (1 cartridge for about 6 oil samples), or pressurized shop air 1 ml Metal housing / Carry handle and shoulder strap / Universal power adapter/charger (9 24 VAC) Built-in thermal printer / LCD-display and keyboard / Memory for 5 samples / RS232C-interface Tube connector for filtered and dry pressurized shop air / Exchangeable CO 2 -gas cartridges, refillable, 1 g filling NiMH-battery, computer controlled recharging for extended battery life Digitaloutput -5VDC / < 2 ma, potential-free output -5VDC / Online-adapter with Minimess tubing M16x2 Bottle sample analysis (58 12 psi); online-analysis ( psi); Monitoring of ECOLINE UMP-45 by ARGO-HYTOS PODSWare for download, storage and management of PODS Pro data under Windows 9X/Me/2 and XP 18.7 lbs (B x H x T) 13 x 13.8 x 7.9 inches We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 4342 USA Tel: Fax: info.us@argo-hytos.com Subject to change us
9 Portable Particle Monitor OPCom portable Particle Counting The Easy Way Easy Compact Cost-Efficient
10 OPCom Portable Particle Counting The Easy Way Particle Counting Compact, Easy and Beneficial OPCom portable is a Plug and Play - Instrument with which the oil cleanliness of hydraulic and hydrostatic lubrication systems can be measured quickly and easily. It is simply connected to the sample port, switched on and gives results regularly. There is no easier way for particle monitoring. OPCom portable displays the cleanliness class according to ISO 446:1999. A computer can be connected to display curves graphically, to archive data and to display how the cleanliness in the system changes over the time. A lot of arising damages can be recognized and prevented. By setting up a database and observing over a longer period of time, the progress of cleanliness in a system at different operating states can be noticed. These insights could enable operators and engineers to optimize the machine and process. With this instrument everybody is easily able get a picture of the cleanliness of his hydraulic system. Technical Data Voltage: Pressure Range: Viscosity Range: 1 24 VDC Internal battery 12 VDC psi (see diagram) 1 2 cst (see diagram) Display: ISO-Classes according to ISO 446:1999 Size Channels: 4, 6, 14, 21 µm (c) Operating Conditions: Oil Temperature: F (viscosity has to be in the specified range) Ambient temperature: F Relative humidity: 1 9 % (non condensing) Interface: Weight: Dimensions L x W x H: Standard accessories: RS lbs 11.6 x 15.4 x 5.7 inches 2 minimess tubes, power cable, RS 232 data cable, software for data recording, manual Pressure and viscosity range Viscosity in SUS psi Permitted operating range 29 psi 3625 psi 116 SUS Pressure in psi Dimensions 11.6 inches 5.7 inches 15.4 inches We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 4342 USA Tel: Fax: info.us@argo-hytos.com Subject to change us
11 OPCom AS Particle Monitor for aerated lubricating fluids Eliminates Air Bubbles Compact Assembly Continuous monitoring Field of Application: Monitoring of Hydraulic Fluids or Lubricants such as Gear Oil that suffers from aeration. Design Description: The OPCom AS system consists of a pump, an OPCom particle monitor and a pressure relief valve. The pump delivers the oil to the OPCom particle monitor and the pressure relief valve which is set to a high pressure. Any air bubbles are compressed so that they either are solved by the oil or so small that they are not detected by the particle counter. A typical application is particle monitoring in aerated gear oil. NEW! Optionally with LubCos H 2 O+ Function Principle: Particle size and concentration is determined using the ISO recommended light extinction principle. The oil flows through the sensor at between 5 and 5 ml/min. A laser beam shines through the oil and is detected by a photo diode. A particle in the beam will decrease the detected intensity. The rate of decrease corresponds to the particle size. This optical principle detects everything which differs optically from the surrounding medium, such as air bubbles. Until now, it has been impossible to monitor gear oil using a particle counter for this very reason. The OPCom AS now allows Continuous Particle Monitoring for applications in this important field. Subject to change /2
12 Technical Data Power Supply Power Flow Rate Viscosity Range Weight Dimensions Connections Max. Inlet Pressure Media Size Channels Display Temperature Range Interface Data Memory 4 VAC,9 KW ca.,3 L/min mm 2 /s ca. 12,5 kg 32 x 383 x 135 inlet: G 1/8 outlet: G 3/8,5 Bar Mineral Oil and Biodegradable Hydraulic Liquids (HETG, HEES...) 4, 6, 14, 21µm(c) Cleanliness Classes acc.iso 446: C C RS 232 > 5 measurements We produce fluid power solutions ARGO-HYTOS GMBH Postfach 116 D Kraichtal-Menzingen Tel Fax info.de@argo-hytos.com 2/2
13 Pa r t i c l e M o n i t o r OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 725 psi 1.1-1us
14 D e s c r i p t i o n Application As stationary particle monitor in hydraulic and hydrostatic lubrication systems. Performance features Protection: By continous controlling of the oil cleanliness, damage can already be recognized in the early stage. This offers the possibility of avoiding machine faults by suitable measures and of extending maintenance and oil change intervals. Special design features Modular Construction: The particle monitor consists of a sensor module and a communication module. The sensor module is selected according to the pressure and viscosity conditions in the working range, the communication module is chosen according to the requirements for data processing. Each sensor module is optionally also availabe with a display, from which the degrees of purity can be read off according to ISO 446:1999. Measurement principle: Standard Accessories DDE-Software Optical fibre optic cable, 19.7 ft Operating instructions The particle monitor operates according to the light extinction principle. The oil flows through the sensor with system pressure and approx ml/min. It is analyzed by a laser. Opposite of the laser a photodiode measures the weakening of the light with presence of a particle and calculates from it the particle size and number. For the tuning of the monitor on different pressure and viscosity ranges different variations of the sensor are selectable. For the installation of the particle monitor particularly lines are suitable in which no large pressure fluctuations and pressure peaks occur, like e. g. pilot oil lines. Under the designation OPCom portable a portable on-line monitor is available, with which by connection to a computer the measuring data can also be plotted and filed. For dimensions and technical data see brochure OPCom portable. Te c h n i c a l D a t a Size channels 4, 6, 14, 21 µm(c) Display Cleanliness classes according to ISO 446:1999 with additional decimal Concentration limit Class 29 according to ISO 446:1999 Operating pressure VDC at approx. 15 ma charging rate Fluid pressure max. 725 psi Temperature range -4 F F Viscosity range > 9 SUS Ambient conditions operation -4 F F, % rel. humidity, non condensing Ambient conditions storing -4 F F, < 98% rel. humidity, non condensing Dimensions System with display LxWxH: 3.7 x 3.4 x 1.8 inches System without display LxWxH: 3.7 x 3.4 x 1.4 inches Weight System with display 2.82 lbs System without display 2.78 lbs Hydraulic fluids Mineral oils and biodegradable fluids (HEES, HETG...) On request: Phosphate ester (e.g. Skydrol) Wetted materials SAE 12 steel, spring steel, synthetic sapphire, chrome, zinc, bronze, aflas, Buna-N Attention: Sensors for Skydrol do not contain Buna-N 268
15 D i a g ra m s Viscosity diagrams / permitted ranges for different sensor versions (see order terms) Viscosity as a function of the pressure (within working range) High pressure ( psi) 14 Medium pressure ( psi) ν [SUS] ν [SUS] p [psi] p [psi] Low pressure ( psi) 14 Without orifice ( psi) ν [SUS] ν [SUS] p [psi] p [psi] C o m m u n i c a t i o n I n t e r f a c e D e s c r i p t i o n Configuration only possible by infrared interface (IrDA). Data recording by computer or data logger over the following interfaces: RS-232 standard RS-232 DTE for serial printers or PDA connections Data logger or PLC systems: 8 channels with in each case - 5 VDC analog output RS-485 with MODBUS record for operation in the network Separate indication with programmable alarm limit and floating contact 269
16 O rder Te r m s The selection of the suitable OPCom takes place in two steps: OPCom 1. Definition of the sensor module and the indication 2. Selection of the communication version For the selection of the sensor module viscosity and pressure in the work area must be known. By means of these parameters the suitable version can be selected on the basis of the permissible ranges in the diagrams. High pressure with display 4 High pressure without display 1 Medium pressure with display 8 Medium pressure without display 7 Low pressure with display 9 Low pressure without display Without orifice with display 6 Without orifice without display 3 High flow with display 5 High flow without display 2 Standard RS RS-232 with DTE-configuration 2 Analog output -5 Volt and RS Separate display and alarm contact 4 Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 91 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to assist you with questions concerning filter application, selection and cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 4342 USA Tel: Fax: info.us@argo-hytos.com Subject to change us 26 27
OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar
Pa r t i c l e M o n i t o r OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar 100.10-1e D e s c r i p t i o n Application As stationary particle monitor in
More informationOil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e
Oil Diagnostic Systems Online and bottle measurement Mobile and stationary operation Lab quality accuracy 100.90-1e The new generation of oil diagnostics Mobile and stationary operation: Compressed air
More informationE 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d
R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationD 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min
Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance
More informationE 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min
Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationE 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm
Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:
More informationPressure reducing valve, pilot operated, Model 3DR
RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features
More informationE 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm
Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationSPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-18F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 05083-5E 18-01 Printed in Japan Outline The KS-18F is a sensor which uses the light scattering method
More informationE 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min
Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:
More informationChange-Over Pressure Filter DFDK
Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationPressure Calibrators. Series PC..., PM...
Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure
More informationSPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-19F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 13012-3E 17-06 Printed in Japan Outline The KS-19F is a sensor which uses the light scattering method
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationD62 - D63 Directional Control Valve l/min
D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4
More informationGAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2
GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationBenefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations
OXYBABY 6.0 for O 2 or O 2 /CO 2 Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationWSTM 01 - Set Water Saturation Temperature - Monitor CE 2004
WSTM 01 - Set Water Saturation Temperature - Monitor CE 2004 - Manual and maintenance instructions Version 1.2 Serial-No.:... Version-/Ref.-Date: 27.05.2005 INTERNORMEN Technology GmbH Friedensstraße 41
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min
More informationDigital pressure gauge Model CPG500
Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance
More informationReal-time gas analysis and software for the management of bioprocessing
Understanding bioprocesses from the lab to the production understanding bioprocesses Real-time gas analysis and software for the management of bioprocessing Understanding bioprocesses for more than 15
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationPneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationADT 761 Automated Pressure Calibrator
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com With a built-in high performance electronic pump and precision pressure controller,
More informationHUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0
High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationDräger X-act 5000 Automatic Dräger Tube Pump
Dräger X-act 5000 Automatic Dräger Tube Pump The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationMEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet
Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97
More informationUser Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S
User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S About this manual. The structure of the manual This user manual is aimed at users
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More informationPressure reducing valve, pilot operated
Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content
More informationCO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype
(R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic
More informationFixed Displacement Pump KFA for commercial vehicles in open circuits
RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationD e s c r i p t i o n
MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and
More informationPneumatic dead-weight tester Model CPB3500
Calibration technology Pneumatic dead-weight tester Model CPB3500 WIKA data sheet CT 31.22 Applications Primary standard for calibrating the scale in a pneumatic range from -1... 120 bar / -14.5... 1,600
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationDigital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN
Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,
More informationHUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationDigital pressure gauge Model CPG500
Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationCMS Contamination Monitoring System User Guide
CMS Contamination Monitoring System User Guide 200.085-EN Covers All CMS Models except -AZ2 (ATEX) Safety Warning Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation,
More informationTHE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED
THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary
More informationPlasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling
SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic
More informationGA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300
Technical Note GA-300 Overview The GA-300 CO2 and O2 Gas Analyzer is easy to use, robust, and adaptable to human, animal, and plant applications. The GA-300 has two analog outputs to allow recording and
More informationMobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)
Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More information...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com
...makes sense! Combined CO 2 /O 2 analyzers Monitor your process in real-time: BlueSens.com OUR CER RQ ...makes sense! The BlueInOne sensor BlueSens is providing modern and inexpensive measuring solutions
More informationRecirculating Coolers
(Chillers) - Basic type Low Temp. - General Type Low Temp. - Intelligent type Selection Guide Recirculating Cooler Basic type General type (Low temp.) Intelligent type (Low temp.) Working Temp. Range (
More information2-way flow control valve Model 2FRM 6
R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D
More informationMPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min
MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationTechnical Information Conducal CLY421
TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationhyprofiltration.com/fsw
A compact, dedicated off-line contamination solution ideal for small reservoirs, gearboxes and diesel engine crankcase conditioning. Element media options for every application including particulate removal,
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationWe measure it. For gas and water installers. testo hpa. bar
Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationThis multi-functional device allows the determination of up to six quality parameters with only one measurement:
Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More information