463XGW Gel Wrap PST Dome Closure
|
|
- Allison Barton
- 6 years ago
- Views:
Transcription
1 463XGW Gel Wrap PST Dome Closure Technical Report Tests Based Upon Bell System Pub Issue 1, Oct TA-TSY Issue 1, Feb And Others May 1996 Issue 1,
2 Table of Contents 1.0 Product Description Closure Kit Contents Closure Chart Test Program Overview Environmental Test Series Accelerated Aging/Insulation Resistance and Corrosion Resistance Temperature Cycling Flood Testing (Water Immersion) Freeze/Thaw Cycling in Water Water Head (Core Water) Corrosion Resistance Sealant Sealant Compatibility and Consistency Sealant Material Odor Corrosion of Copper 3.3 Fungus Growth UV Resistance Shock Resistance Impact Resistance Compression Drop Performance Verification/Test Procedure Design and Fabrication Testing Non-Metallic Chemical Resistance of Closure Material and Assembled Closure Tools Conclusions
3 1.0 Product Description The 3M 463XGW Gel Wrap PST Dome Closure is designed to be a protection device used in pedestal, hand hole, pole mount, wall mount to guard splice modules (e.g., 3M 4000D, AT&T 710 module) on filled or unfilled cables. A specially formulated encapsulant is not needed. The 3M MS 2 463XGW Gel Wrap PST Dome Closure is easy to install since no encapsulant mixing and curing is required and there is no need to use heat or special tools. The Gel Wrap PST is designed to maintain the integrity of the closure body against any water or moisture entering the closure from external and to maintain the high insulation resistance (IR) between all wire pairs. The closure is resistant to saltwater (3.5% sodium chloride), acid (3% sulfuric acid), base (0.2N sodium hydroxide), and cable filling compounds. The closure's sealing performance of Gel Wrap PST is compatible with encapsulant currently applied in the field condition. The user can feel at ease when replacing old encapsulated closures with 3M 463XGW Gel Wrap PST Dome Closure. The 3M 463XGW Gel Wrap PST Dome Closure will accommodate up to 600 pairs of service wire (using 3M MS 2 module connector) with a maximum bundle diameter of 5.3 in. (135 mm) in butt splice configuration. A closure capacity chart is shown on page Closure Kit Contents The 3M 463XGW Gel Wrap PST Dome Closure kit contents are as follows: (A) 4634GW and 4635GW Dome (A) Gel End Seal (B) Gel Wrap (C) PST (D) Sheath Scuff (E) (C) (F) (D) (E) (B) (A) 4636GW Dome (A) Gel End Seal Core (B) Gel Sealant Strip (C) Gel Wrap (D) PST (E) Sheath Scuff (F) (B) (D) (E) (C) (F) (B) Additional Materials Required: Vinyl Tape Shield Bond Connectors 3M E-Z Wrap or equivalent 3
4 1.2 Closure Chart The chart below shows closure dimensions, closure capacities and cable sizes for 3M 463XGW Gel Wrap PST Dome Closure. Closure (W x D) Outside Dim. Closure (H) Height Approx. Bundle Diameter Minimum Reliable CAD Pedestal Main Cables Terminal Cables Branch Cables Drop Cables *Approx. Splice Range 4634GW 4635GW 4636GW 2.77" x 2.5" (70 x 64 mm) 22.5" (572 mm) 2.5" (64 mm) 0.4" - 0.6" (10-15 mm) " max (9 mm) max 2 max 100 pr. - MS 2 50 pr. - UR 4.75" x 3.7" (121 x 94 mm) 22.5" (572 mm) 3.9" (99 mm) 0.4" - 0.6" (10-15 mm) 0.7" -1.0" (18-25 mm) 0.35" max (9 mm) max 2 max 300 pr. - MS pr. - UR 6.25" x 5.2" (159 x 132 mm) 23.5" (597 mm) 5.3" (135 mm) " - 1.1" (13-28 mm) 0.9" - 1.6" (23-41mm) 1.4" - 2.5" (36-64 mm) 0.4" - 0.8" (10-20 mm) 0.9" - 1.3" (23-33 mm) 0.35" max (9 mm) max 2 max 600 pr. - MS pr. - UR *Note: Based on two bank 3M MS DWP and 3M Scotchlok connectors installed per 3M practices. Examples: 100 pair means 100 pair IN and 100 pair OUT or 100 pair straight splice. W D H 4
5 2.0 Test Program Overview To assess the long term performance reliability of the 3M 463X PST/Gel Wrap Dome Closure, the closures were subjected to a number of tests which exposed them to conditions more severe than anticipated in actual field use. The following sections describe the specific tests that were performed on this product and report the results obtained. All tests, except the fungus test, were performed by 3M Telecom Systems Division s Network Apparatus Test Lab in Austin, TX. The fungus test was performed by an independent lab. The tests were mostly based upon the Bell System Technical Reference Pub 55004, Waterproof Splice Closures, Issue 1, October 1981, Technical Advisory TA-TSY , Pedestal Wire Work Enclosures, Issue 1, Feb. 1986, and other appropriate specifications commonly used in the telecommunications industry as a guideline. The report also points out if a deviation in the testing condition from the Bellcore specification was used in the test. In some situations, the deviation means that a more severe environmental testing condition than the Bellcore specification was adopted in the test, (i.e., such as more rapid transition and higher number of thermal shocks between the two extreme temperatures, using aged samples instead of new samples for the test, etc.) 3.0 Environmental Test Series Ten samples were prepared at normal room temperature, their description is listed below. Test Sample Description Sample Wire Size # of Service Wire Number (AWG #) Wire Pairs Connector * Two 3M MS Ds & Two AT&T 710s 7, Four 3M MS Ds 9, Eight 3M MS Ds *Note: All samples use AT&T Flexgel service wire cable 3.1 Accelerated Aging/Insulation Resistance and Corrosion Resistance To test the seal against water or moisture entry to prevent corrosion and degradation of insulation resistance, all samples went through three environmental tests in the following order: Temperature Cycling, Flood Testing, and Freeze/Thaw Cycling in Water. The above test procedure is different from the Bellcore specification. The aged samples instead of new raw samples were used in each subsequent test. This test is more severe than the Bellcore requirement. The insulation resistance of all samples was measured after each test and any reading under 1 x 10 9 ohms is considered a failure. The details of each test condition in the sequence and its test results are in the following sections to
6 3.1.1 Temperature Cycling The samples (samples #1-6) were temperature cycled between -40 F (-40 C) and 140 F (60 C) for 50 cycles. The cycle time was four hours. The dwell time at each extreme temperature and the transition time between the two extreme temperatures were one hour each. At the conclusion of the test, all samples were examined for any deterioration of the external closure material. No sign of deterioration was found. The insulation resistance measurement was performed immediately after the temperature cycling test. The overall minimum insulation resistance value was 1.0 x ohms, one order of magnitude above the minimum requirement of 1 x 10 9 ohms. All samples passed the test. The Insulation Resistance Data After Temperature Cycling Test Sample Number Average (ohms)* Minimum (ohms) Pass/Fail x x Pass x x Pass x x Pass x x Pass x x Pass x x Pass *Note: The insulation resistance (IR) measurement includes IR between Tip to two adjacent Rings, IR between Ring to two adjacent Tips, and IR between wire to shield for each service wire pair. Average data is the overall average of all data measured for each sample. Minimum data is the lowest IR data obtained for each sample Flood Testing (Water Immersion) The temperature cycling tested samples (samples # 1-6) were submerged in tap water at a depth of 42 inches (107 cm) at a temperature of 76 F ± 2 F (24 C ± 1 C) for 30 days. During testing, 48 V DC of power from a current limited short tester was applied to all service wire pairs to simulate working pairs and to detect a possibility of an electrical short in each working pair. The IR was measured at 500 V DC after one day and every week thereafter. At the end of the test, the IR between any two wire pairs and all pairs to shield should be at least 1 x 10 9 ohms. All samples passed the test and the lowest IR was at least one order of magnitude above the requirement. The Insulation Resistance Data After Flood Testing Sample Number Average (ohms)* Minimum (ohms) Pass/Fail x x Pass x x Pass x x Pass x x Pass x x Pass x x Pass *Note: The insulation resistance (IR) measurement includes IR between Tip to two adjacent Rings, IR between Ring to two adjacent Tips, and IR between wire to shield for each service wire pair. Average data is the overall average of all data measured for each sample. Minimum data is the lowest IR data obtained for each sample 6
7 3.1.3 Freeze/Thaw Cycling in Water In this test, aged samples were used rather than preparing new samples. The test samples included all six samples (samples #1-6) that had gone through a series of accelerated aging tests as described in sections & The test was performed per US West PGF #N600M07, Issue 1, May 1992, section (both Bell System Pub and Bellcore TA-TSY do not call for this test). Samples were immersed in water to a depth of ten inches (25.4 cm) of water. The samples were cycled between -40 F (-40 C) and 158 F (70 C) for 50 cycles (59 days). The cycle time was 28 hours, ten hours at each extreme temperature and four hour transition time between the hot and cold temperature extremes. During aging, 48 V DC of power from a current limited short tester was applied to all service wire pairs to stimulate a working pair and to detect a possibility of an electrical short in each working pair. The IR was measured at 500 V DC after three days and every week thereafter. Again, there was no sign of deterioration of the closure material at the end of test and all samples had insulation resistance values greater than the minimum requirement of 1 x 10 9 ohms. The Insulation Resistance Data After Freeze/Thaw Cycling in Water Test Sample Number Average (ohms)* Minimum (ohms) Pass/Fail x x Pass x x Pass x x Pass x x Pass x x Pass x x Pass *Note 1: The insulation resistance (IR) measurement includes IR between Tip to two adjacent Rings, IR between Ring to two adjacent Tips, and IR between wire to shield for each service wire pair. Average data is the overall average of all data measured for each sample. Minimum data is the lowest IR data obtained for each sample Water Head (Core Water) Again, the sample (sample #1) that had gone through a series of accelerated aging tests as described in sections instead of using new sample as specified by the Bellcore was used for this test. One end of the service cable was cut one foot (30.5 cm) from the closure sample and a three foot (91.4 cm) water head was connected to the cut end of the service cable. The test was conducted at room temperature, approximately 72 F (22 C), for 14 days. This test was done in a condition that was per US West PGF #N600M07, Issue 1, May 1992, section After the test, the water head was removed from the sample and insulation resistance measured. It met the minimum requirement of 1 x 10 9 ohms. The sample was then dissected for examination with no rust or other degradation observed as described in section The test was done and the result is valid only for filled cable. The Insulation Resistance Data After Water Head Test Sample Number Average (ohms)* Minimum (ohms) Pass/Fail x x Pass *Note: The insulation resistance (IR) measurement includes IR between Tip to two adjacent Rings, IR between Ring to two adjacent Tips, and IR between wire to shield for each service wire pair. Average data is the overall average of all data measured for each sample. Minimum data is the lowest IR data obtained for each sample. 7
8 3.1.5 Corrosion Resistance Only two (samples # 5 & 6) of six samples which had gone through a series of different aging tests (see sections ) were inspected for any possibility of corrosion inside the samples right after the aging test. The remaining four samples (samples # 1-4) were not inspected until after the conclusion of the water head test (see section 3.1.4) & chemical immersion test (see section 4.1.2). An analysis was made of the tested samples for the degree of rust in accordance with ASTM D610. A rust grade of nine or better is required. All samples passed the test. The Rust Grade Data After Various Aging Tests Sample Number Sample History Rust Grade Pass/Fail 1 Aging Series + 3 ft. Water Head Better Than 9 Pass 2 Aging Series + 3% Sulfuric Acid Better Than 9 Pass 3 Aging Series +.2N Sodium Hydroxide Better Than 9 Pass 4 Aging Series + Kerosene Better Than 9 Pass 5 Aging Series Only Better Than 9 Pass 6 Aging Series Only Better Than 9 Pass Note: "Aging series" denotes a series of environmental aging tests discussed in sections from to Sealant Since encapsulant is not used in this product, the test results for the gel wrap material used are included Sealant Compatibility and Consistency The test of the sealant compatibility and its consistency was done on samples that went through the accelerated aging test (see sections to 3.1.3), water head test (see section 3.1.4), and chemical immersion test (see section 4.1.2). All closure samples were opened. The gel wrap was found to be compatible with the wire and connector materials and retained its sealing properties over the installed connector module based on visual inspection and insulation resistance measurement. Therefore, the gel wrap should maintain its compatibility and sealing consistency over the expected product s service life Sealant Material The material contains no toluene diisocyanate (TDI) Odor The PST material smells like rubber and gel wrap is odorless. 8
9 3.2.4 Corrosion of Copper This test was performed per Bellcore TA-TSY , Issue 1, 2/86, section 4.2. Current flow greater than one microampere or any visual evidence of copper corrosion is considered a failure. The boards were washed initially with pumice soap and a nylon brush. Each board was suspended above potassium sulfate covered with a saturated solution of saltwater. Each board was connected individually to a 50.9 V instead of a 45 V power source. Current readings were taken for each board at the beginning and at the end of the 14 day test. All samples showed a current reading less than 100 nanoamperes (1 x 10-7 amperes), which is one order of magnitude less than the maximum allowed current of 1 x 10-6 amperes. No evidence of copper corrosion was found. The Current Reading of 14 Day Corrosion of Copper Test Sample Number Initial Current (na)* Final (Day 14) Current (na)* Pass/Fail Pass Pass Pass Pass Pass Pass * Note: one nanoampere (na) = 1 x 10-3 microampere ((A) = 1 x 10-9 ampere (A) 3.3 Fungus Growth The splice closure material samples were tested in accordance with ASTM G for 28 days. A control sample, agar, was tested along with the subject test samples to verify the inoculation. A rating of zero, no visible fungus growth on the specimen, was required. Six samples of PST and two samples of the Gel Wrap were submitted to an independent outside lab. for testing. A rating of zero was obtained for all test samples except the control sample. The Rating of Fungus Growth Test Test Subject All Closure Material Samples Control Sample-Agar PST 0* 4* Gel 0 4 *Note: 0 = no visible fungus growth on the specimen, 4 = heavy growth (> 60%). 3.4 UV Resistance Ten test samples (including five control samples) of each material were exposed in a UV Weatherometer for 30 to 90 days. The source of UV is B type with a peak emission at 313 nm. The material should not have a reduction in tensile strength greater than 20% of their original value (measured with control samples), after being exposed to UV. The test results showed there was less than 2% variation from the control sample. Both materials meet the requirement. The Results of UV Resistance Test Test Subject Closure Material Samples Control Samples PST lb. (510 N) lb. (502 N) Polyethylene Dome lb. (1,158 N) lb. (1,170 N) *Notes: 1. The PST and polyethylene dome were exposed to UV for 90 & 30 days respectively. 2. The data shown is the average tensile strength of all five samples. 9
10 3.5 Shock Resistance Three physical tests were used to test the 3M 463X PST/Gel Wrap Dome Closure s ability to withstand physical handling and abuse anticipated with normal field application. The tests include impact resistance test, compression test, and drop test Impact Resistance Four samples (samples # 7-10) were preconditioned at 0 F (-17.8 C) at least two hours before test. The impact was positioned at the approximate mid-point & bottom of the dome body and the PST-dome interface. The impact consists of a 10 lb. (4.5 kg) weight with a 1 in. (2.54 cm) spherical radius head and a 20 lb. (9.1 kg) weight with a 2 in. (5.08 cm) spherical radius head, dropped from a height of 5 ft. (1.52 m) for 50 ft-lbs. & 100 ft-lbs. respectively. The test was repeated for all samples at 100 F (37.8 C). There should be no cracking or breaking of any of the samples. All samples passed with no visible damages on the closure body. In addition, no discontinuity in shield bond connection was observed for all samples tested Compression The sample preconditioning was done the same as for impact test (see section 3.5.1). The sample (samples # 7-10) was placed between a pair of flat, rigid surface of 2 ft. 2 (0.19 m 2 ). A 300 lb. (136 kg) compression load was applied on the platform for 15 min. The dimension of the closure was measured before applying the compression load, after applying the load for 15 min., and after the closure s temperature reached the normal room temperature with the load removed. The changes in the closure s dimension should be less than 10%. All samples met the requirement Drop Six closure kits were individually packaged as they will be received from the manufacturer. The sample packages were preconditioned at 15 F (- 9.4 C) overnight before being dropped from a height of six ft. (183 cm) onto a hard brick surface. Each package was dropped with a different part of the package making contact with a hard brick surface. There should be no cracking or breaking of any of the components or parts in the sample package. All samples passed with no visible damages on all components or parts in all sample packages. 10
11 4.0 Performance Verification/Test Procedures 4.1 Design and Fabrication Testing Non-Metallic Chemical Resistance of Closure Material and Assembled Closure The requirements are that all materials should be spray and solvent resistant and should resist chemical pollutants and not develop any stress cracks, stripping, molting, texture or color change when exposed to the chemicals such as 3% sulfuric acid,.2n sodium hydroxide, Kerosene, and 10% Igepal CO-630. Test of closure materials was performed in the above mentioned four different chemicals. In addition, three assembled closure samples which went through accelerated aging test before (see sections ) were immersed in base, acid and Kerosene (one in each chemical) for a period of one week. The PST showed no sign of degradation except it showed expansion and gained weight in Kerosene. The closure samples were then submerged in 5 ft. (152 cm) of water for one week to test the closure s sealing ability after chemical immersion. All three samples showed no insulation resistance below the minimum requirement of 1 x 10 9 ohms. The water did get into the dome closure sample which was immersed in Kerosene, but the gel wrap was able to block the water from contacting with the splice module. Therefore, the insulation resistance of all wire pairs was not affected. The Insulation Resistance Data After Chemical Immersion Plus 5 ft. Water Immersion Test Sample Number Average (ohms)* Minimum (ohms) Pass/Fail #2 (3% sulfuric acid) 1.2 x x 10 9 Pass #3 (0.2N sodium hydroxide) 1.2 x x 10 9 Pass #4 (Kerosene) 1.2 x x 10 9 Pass Tools The use of specialized tools or equipment not normally at the craftsperson's disposal should be avoided. This was confirmed by a review of installation instructions that this requirement was met, no special tools are required to install these closures. 5.0 Conclusions The 3M 463X PST/Gel Wrap Dome Closures were subjected to a variety of environmental, corrosion resistance, shock resistance, and chemical resistance tests. The tests are based upon Bell System Pub 55004, TA-TSY , and other appropriate specifications commonly used in the telecommunications industry. In some tests, the tests were performed in a much harsher environmental testing condition than the Bellcore requirement to test the product to its limit. This was done by using the same samples that had gone through a series of the accelerated aging tests before, rather than preparing new samples and added additional aging tests. In all insulation resistance measurements carried out at different stages of the accelerated aging test, the test results indicate the minimum value is one order of magnitude higher than the minimum requirement of 1 x 10 9 ohms. The tests showed that the 3M 463XGW Gel Wrap PST Dome Closure provides an excellent seal against water or moisture entry to the closure protecting the splice module of the service wire cable. In addition, the closure was shown to be corrosion, shock, and chemical resistive. Based on these results, the long term durability of the splice protection is assured. The advantage of using the gel wrap to replace the encapsulant is to greatly speed up the closure installation time. The product is also easy to install since there is no need of using heat or any special tools for installation. These are important features need to be taken into account for the applications of emergency repair, the existing network rehab & reroute, etc. The test results documented in this report also assure that the performance of the closure is not compromised by replacing the encapsulant with the gel wrap. For further information regarding specific agency approvals please contact your 3M Telecom Systems Division representative. 11
12 Important Notice All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed. SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS THAT WERE DEFECTIVE. Telecom Systems Division 6801 River Place Blvd. Austin, TX / Recycled paper 40% pre-consumer 10% post-consumer 12 Litho in USA 3M
Fiber Optic Splice Closures
Fiber Optic Splice Closures . Products Descriptions of Optical Closure and Splice Tray FOCSS FOCS FOCM Splice Tray-2C Splice Tray-24C Dimensions (mm): 225(l) 08(w) 2(h) Dimensions (mm): 68(l) 9(w) 9(h)
More informationFeatures Forward facing doors which allow expansions to the side of existing cabinets.*
The Network of Networks 3M Add-on Terminal 4220P Family The 3M Add-on Terminal 4220P Family provides a flexible expansion alternative for adding up to 900 additional pair to either the left or right end
More informationTechnical Data Sheet. R&M Closures
R&M Closures About this data sheet Edition 3.0 This document has been drafted with utmost care and reflects the products July, 2013 engineering level at the time of publication. Amendments or corrections
More informationPSR-4000 HFX Series (UL Name: PSR-4000DE / CA-40HF)
PSR-4000 HFX Series (UL Name: PSR-4000DE / CA-40HF) LIQUID PHOTOIMAGEABLE SOLDER MASK Application by Screen Printing Dark Green Satin Available in DI version Halogen-Free RoHS Compliant Compatible with
More informationOPERATION AND INSTRUCTION MANUAL
OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWS100N-316-CTS Patent US # 8,424,638 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationThe Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.
The Sealing Compound encapsulates the electrical splices, provides a strain relief for the conductors, acts as a water block, eliminates air voids which tend to act as pumps to draw in water during pressure
More informationOPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS
OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS (Patent Pending) WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT
More informationElectrical Tapes Selection Guide. 3Innovation
Electrical Tapes Selection Guide Innovation M Electrical Tape Chart PRODUCT NAME PRODUCT TAPE SIZES TEMPERATURE TYPICAL DESCRIPTION THICKNESS AVAILABLE RATING APPLICATIONS Vinyl Electrical Tapes Scotch
More informationTECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS
TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications
More informationMay08 Rev B
Qualification Test Report 0.64 mm Generation Y Terminal 501-657 20May08 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on the Tyco Electronics 0.64 mm Generation Y Terminal to determine its conformance
More informationOPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT
OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More informationPULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING
PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering
More informationOPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N
OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.
More informationTDUX Inflatable Duct Sealing System 1.0 General Product Information
TDUX I N S T A L L A T I O N I N S T R U C T I O N Inflatable Duct Sealing System 1.0 General Product Information The TDUX inflatable duct sealing system is a wraparound, inflatable, mastic-lined bladder
More informationCOOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions
Voltage Regulators MN800013EN Effective February 2016 Supersedes S800-70-1 August 2012 COOPER POWER SERIES 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles
More informationpvc well casing & drop pipe
C e r t a i nte e d pvc well casing & drop pipe P V C We l l P r o d u c t s Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due
More informationDT400/436 Tee Connector Installation Instructions
Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION
More informationK&B Vault and Riser Closures
K&B Vault and Riser Closures K&B Vault Closures K&B Closures are strong, lightweight, and protect a wide variety of vault splice configurations with an air and water tight seal. K&B closures offer a full
More informationRescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)
Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m) Patent # US 9,677,333 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More informationOPERATION AND INSTRUCTION MANUAL
OPERATION AND INSTRUCTION MANUAL Dual Extension Swivel Anchor Model: SWD100N-036 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More informationPLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000
More informationSterile Visual Flow Indicator
Sterile Visual Flow Indicator Sanitary Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com Web
More informationOPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N
OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.
More informationA N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions
A N C H O R T A B S N O R T H W E S T www.anchortabs.com ANCHOR TAB VF Patented User Instructions National standards, and state, provincial, and federal laws, require installer/user of this product to
More informationNorrsken Family Booklet
Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation
More informationInstallation and Operation Manual
Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com
More informationSplice Protection Products
Copper Outside Plant Products 3 Splice Protection Products How to Search this Catalog This digital catalog provides you with two quick ways to find the products and information you re looking for. Just
More informationPRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A
SFP+ Cage and Cage Assembly 1 of 8 A 1.0 Objective This specification defines the performance, test, quality and reliability requirements of the _Small Form-factor Pluggage (SFP+) product. 2.0 Scope This
More informationRescue Ladder Model: CTB LDR-RSC 18ft (5.48m)
Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m) IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationINSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)
INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT) - WARNING- IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS.
More informationPSR-4000 LDI (US) (UL Name: PSR-4000 JA / CA-40 JA)
PSR-4000 LDI (US) (UL Name: PSR-4000 JA / CA-40 JA) LASER DIRECT IMAGING SOLDER MASK For LDI Exposing Available in Green, Blue, Black, Clear and Red Satin Finish Halogen-Free RoHS Compliant Compatible
More informationCylinder Adhesive for Geotextile Seaming
3M Scotch-Weld Holdfast Cylinder Adhesive 70 Technical Bulletin June, 2011 Product Description Construction grade, versatile cylinder spray adhesive formulated for a wide variety of Geotextiles. Application
More informationFibre Optic Closure 2179-CS
Fibre Optic Closure 2179-CS The Fibre Optic Closure 2179-CS is designed and developed based on the proven 3M sealing technology. It is made of plastic molded parts and mastic sealing materials. Closing
More informationKATRADIS MARINE ROPES INDUSTRY S.A.
KATRADIS MARINE ROPES INDUSTRY S.A. USER S MANUAL MOORING TAILS -NIKA-Nylon -NIKA-Polyester -Mixed Polyester/Nikasteel REV 1.0 Page 1 USER S MANUAL The use of mooring tails is highly recommended with low
More informationRescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)
Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m) IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
More informationPERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY, M-169A/AIC
PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-26542/12C 12 September 2012 SUPERSEDING MIL-PRF-26542/12B 11 February 1999 MICROPHONE ASSEMBLY, M-169A/AIC This specification sheet is approved for use
More informationREACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI
REACH 2500 WEIGEL STREET CADILLAC, MI 49601 Phone: 800-250-5132 Local: (231) 779-4390 Fax: (231) 779-4399 E-Mail: sales@piranhahose.com Web Site: www.piranhahose.com sales@piranhahose.com www.piranhahose.com
More informationSIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information
SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate
More informationCRC-EVANS SADDLE BAG WEIGHT SYSTEM
CRC-EVANS SADDLE BAG WEIGHT SYSTEM The Saddle Bag is a modern way of pipline bouyancy control, designed especially for use in wetlands and environmentally sensitive areas. Saddle Bags are a more effective
More information3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor
Membrane Contactors 3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety Information 3 II. Required Materials 4
More informationHuiyuan Communication Technologies Co.,Ltd.
6.1 Picture of HY-10-D-002 External Dimension (mm):φ260 465 Weight (kg):5.15~5.8one unit 6.2 Structure of HY-10-D-002 Bilateral spare fiber tray The cover Multi-angle splice tray The cover of splice tray
More informationMETEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions
METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical
More informationproduct use, care, & inspection Document Released: January, 10, 2012 Approved By: Bryce Merrick
product use, care, & inspection Document Released: January, 10, 01 Approved By: Bryce Merrick product use, care, & inspection Contents product use 03 product warning 03 tuff bucket ANATomy 04 how to properly
More informationTechnical Data Package
Technical Data Package DuPont Tychem CPF3 Coveralls C3198T & C3199T Compliant with NFPA 1992, 2012 Edition Consult the DuPont Tychem User Manual for Instructions on Use Revised December 2013 This information
More informationOPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N
OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N Patent # US 8,424,638 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More informationOPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248
OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.
More informationQUALIFICATION TESTS FOR A TYPE B (U) PACKAGE
14th International Symposium on the Packaging and Paper # 028 Transportation of Radioactive Materials (PATRAM 2004), Berlin, Germany, September 20-24, 2004 QUALIFICATION TESTS FOR A TYPE B (U) PACKAGE
More informationSUPER SLIDER BEAM ANCHOR ADJUSTABLE FROM Model # BWA030N
SUPER SLIDER BEAM ANCHOR ADJUSTABLE FROM 12-30 Model # BWA030N IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR
More informationUSER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR
Instructions for the following series products: Concrete Bolt Connector Models: 2100041, 2100066, 2104560, 2104561, 2104562 USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR This manual is intended
More informationULTRA-LIGHT DUTY ONBOARD AIR SYSTEM
ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM PART NO. 10000 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
More informationWATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity
WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationRESISTORS, HEATERS, FLEXIBLE, SINGLE AND DOUBLE LAYER. ESCC Detail Specification No. 4009/002
Page 1 of 16 RESISTORS, HEATERS, FLEXIBLE, SINGLE AND DOUBLE LAYER ESCC Detail Specification Issue 8 February 2018 Document Custodian: European Space Agency see https://escies.org PAGE 2 LEGAL DISCLAIMER
More informationDeep Submersible Level Transducer Series 300DS
KPSI Transducers Deep Submersible Level Transducer Series 300DS FEATURES! Custom Level Ranges up to 4614 ft (1408 m) H 2 O! Accuracy of ±0.5% FS! Analog Outputs of 4-20 ma or 0-5 VDC! Welded 316 SS Construction!
More informationPLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000
More informationCOOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN
Deadbreak Apparatus Connectors MN650042EN Effective February 2017 Supersedes December 2009 (S550-10-1) 200 A 15/25 kv class elbow installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES
More informationCOOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN
Deadbreak Apparatus Connectors MN650043EN Effective February 2017 Supersedes October 2004 (S550-12-1) 200 A 15/25 kv class deadbreak straight connector installation instructions COOPER POWER SERIES DISCLAIMER
More informationPSR-4000BN DI Colors (UL Name: PSR-4000BN / CA-40 BN)
PSR-4000BN DI Colors (UL Name: PSR-4000BN / CA-40 BN) LIQUID PHOTOIMAGEABLE SOLDER MASK Screen or Spray Application Designed for the latest DI Technology Available in Black, Blue, White, Clear, Red, Yellow,
More informationGENERAL GUIDELINES FOR PROPER RIGGING PRACTICES AND INSPECTION & REMOVAL CRITERIA FOR SLINGS PER OSHA
GENERAL GUIDELINES FOR PROPER RIGGING PRACTICES AND INSPECTION & REMOVAL CRITERIA FOR SLINGS PER OSHA 1910.184 SAFE OPERATING PRACTICES -.Whenever any sling is used, the following practices shall be observed:
More informationASAHI/AMERICA EFFECTIVE: 12/01/08. Dimensional Guide. Halar (E-CTFE) Piping & Valves
ASAHI/AMERICA EFFECTIVE: 12/01/08 al Guide Halar (E-CTFE) Piping & Valves Halar al Guide Pipe 5 meter-16.4 length da(od) s Asahi in in part# 1/2" 20 SDR 21 0.79 0.07 5501005 3/4" 25 SDR 21 0.99 0.07 5501007
More informationS-200W LP WHITE THERMAL CURE LEGEND INK
S-200W LP WHITE THERMAL CURE LEGEND INK Screen Print Application Longer Pot Life (minimum of 14 days) Meets NASA Outgas Requirement RoHS Compliant Excellent Heat Resistance in HASL Low Odor 1 P a g e Revised
More informationINSTRUCTIONS warranty watch care
INSTRUCTIONS warranty watch care Congratulations on the purchase of your Szanto timepiece! Please read and follow the watch care instructions carefully to ensure that you are able to enjoy your timepiece
More informationPSR-4000BN Series (UL Name: PSR-4000BN / CA-40 BN)
PSR-4000BN Series (UL Name: PSR-4000BN / CA-40 BN) LIQUID PHOTOIMAGEABLE SOLDER MASK Screen or Spray Application Available in Green or Dark Green Semi- Gloss Finish RoHS Compliant High Viscosity version
More informationPSR-4000 MP (UL Name: PSR-4000MP / CA-40MP)
PSR-4000 MP (UL Name: PSR-4000MP / CA-40MP) LIQUID PHOTOIMAGEABLE SOLDER MASK Screen or Spray Application Dark Green, Matte Finish RoHS Compliant Excellent Solder Ball Resistance Compatible with Lead-Free
More informationVERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # VBC014N
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # VBC014N WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More informationFall Protection Checklist. Guardrail System
Fall Protection Checklist Location/Department: Date of Inspection: Inspectors: Corrective Actions: Work order/memos were issued: Yes No Date issued: In accordance with the MIOSHA and OSHA standards the
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More information[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX
173.300 [Reserved] 173.301 General requirements for shipment of compressed gases and other hazardous materials in cylinders, UN pressure receptacles and spherical pressure vessels. (a) General qualifications
More informationPrimary Terminals & Connectors
Primary & Pure electrolytic copper with electro-tin plating for corrosion resistance Deep internal serrations promote firm wire grip for maximum strength Insulation (where applicable) is color coded to
More informationMODELS (2 foot Version) (4 foot Version)
INSTALLATION AND MAINTENANCE MANUAL DUROSITE LED LINEAR FIXTURE Document No: 9100-127-2571-99 Rev A April, 2016 MODELS (2 foot Version) (4 foot Version) ALL LAE ALL LBE These instructions contain important
More informationUser s Guide Temperature Sensor Converter TSC-599
User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405
More informationCOOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN
Connectors MN650027EN Effective November 2016 Supersedes January 2014 (IS550-11-1) DS250 deadbreak straight connector installation instructions interface A COOPER POWER SERIES DISCLAIMER OF WARRANTIES
More informationCOOPER POWER. SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions. Surge Arresters MN235022EN 0.
Surge Arresters MN235022EN Effective November 2016 Supersedes July 2011 (S235-87-1) COOPER POWER SERIES VariSTAR type AZE station class surge arresters installation and maintenance instructions 0.5 0.866
More informationMethod of Making and Curing Concrete Specimens in the Field for Compression and Flexural Tests
Method of Making and Curing Concrete Specimens in the Field for Compression and Flexural Tests 1. Scope: This is the procedure for making and curing concrete specimens to be used for compression and flexural
More informationOperating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL
Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents
More informationSASK-A-POLE OWNERS AND USERS MANUAL
SASK-A-POLE OWNERS AND USERS MANUAL GENERAL INFORMATION The Saskatchewan Abilities Council s Sask-a-Pole accessibility and transfer aid is designed to help provide safe and easy access to chairs, beds,
More informationTechnical Data Sheet PART A & PART B
Technical Data Sheet PART A & PART B NuPool Epoxy 2 Pack System PART A Product Description NuPool Epoxy Features: NuPool Epoxy is an isocyanate free, high build gloss epoxy coating that is impervious to
More informationSDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual
SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com
More informationA hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.
CONTENTS Introduction Pressure Pressure Drop Temperature Rating Bend Radius Conclusion Additional Information SIDEBAR: Understanding Hydraulic Hose Reinforcement INTRODUCTION Hydraulic hose has a finite
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationGASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a
More informationIAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More informationDEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA
SeaLite Six DEEPSEA POWER & LIGHT Record product serial number below as it appears on the nameplate. Serial # Pin-out Postive = Pin Negative = Pin Ground = Pin Dimming (if applicable) = Pin T: (858) 576-1261
More informationFast Rope / F.R.I.E.S. Specifications. Mil-F-44422
Fast Rope / F.R.I.E.S. Specifications Mil-F-44422 HELI-VAC FAST ROPE SYSTEMS provide safe and efficient methods for infiltrating and extracting personnel to and from target locations. A special low stretch,
More informationMoai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes
Submittal Sheet Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Galvanized An after fabrication hot dipped galvanized finish is available. Powder Coat Our powder coat finish assures a high level of
More informationRescue Ladder Model: KT ft (5.48m)
Rescue Ladder Model: KT36164 18ft (5.48m) IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE
More informationOperator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)
Operator s Manual 71 Test Kit for Static Control Surfaces (Megohmmeter) INTENDED USE The 3M Model 71 Megohmmeter is designed to measure the resistance of static control work surfaces and flooring. This
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationWorld Area Differences Technical Information
World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National
More informationTD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual
Relied on Worldwide in the Most Extreme Conditions TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490
More informationINSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr
INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION
More informationRoofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP
Roofing Primer Primer-610 Spray Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP PRODUCT DESCRIPTION TESTS PRODUCT DATA FORM Solvent-based synthetic-rubber bonding agent in a pressurized
More informationAIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.
2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
More informationTranslation of the original Operating Instructions for HKS rubber compensators
Because of their flexible elements and mechanisms, HKS rubber compensators are susceptible to damage of all types and adverse loads in operation. For reliable operation of a compensator and, thus, the
More informationTechnical Standard Order
Department of Transportation Federal Aviation Administration Aircraft Certification Service Washington, DC TSO-C75 Date: 9/4/63 Technical Standard Order Subject: TSO-C75, HYDRAULIC HOSE ASSEMBLIES Technical
More information