Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing

Size: px
Start display at page:

Download "Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing"

Transcription

1 Development Report Walker Barrier 10 Ergoclean Gloveport Interface And Single Piece Gauntlet Performance Testing March 25, 2005 Revised August 21, 2007 Dynamic Design Pharma, Inc.

2 1. Walker Barrier Gloveport Interface The GIT-LC glove integrity tester must be capable of interfacing to all standard gloveport designs in the industry. One of these designs is Walker Barrier s Ergoclean standard 10 inch molded gloveport Gloveport part number: GPA-UL-10VL 10 inch molded Ergoclean gloveport assembly Sealing problems with standard design Although sealing very well from inside the isolator, the gloveport has a sealing issue when pressurized from the outside to inflate the glove. Figure 1 shows the leak path. Figure 1. Leak path in standard gloveport design Comments: The leak path shown clearly does not allow the simple attachment of a sealing plate to the outside of the gloveport The small O ring that schematically should yield the required seal, is not reliable enough to assure a good seal, particularly along the straight sides of the gloveport Solution of sealing problem with standard design A simple modification to the standard design gloveport corrects this sealing problem. Figure 2 shows the modification. Page 2 of 11

3 ADDED "O" RING Figure 2. - Leak path elimination with standard O ring The added O ring is a standard 6 mm cord diameter silicone seal and it is bonded to the gloveport outer ring using clear silicone RTV adhesive Simple tightening of the top and bottom clamping screws was found to be insufficient to assure a reliable seal Clamping force all around the circumference of the gloveport is necessary. See interface design for means of meeting such requirement Interface design Figure 3 shows a gloveport interface design that yields good clamping force all around the gloveport, only requires only the addition of the above mentioned O ring to the gloveport, making field retrofit of existing systems quite simple. Page 3 of 11

4 INTERFACE ASSEMBLY ADDED CLAMPING PLATE LOCKDOWN T-SCREWS SEAL ADDED "O" RING Figure 3. - Gloveport interface design The interface plate assembly clamps onto the outer body of the gloveport with six Tee-screws located around the circumference of the gloveport A stainless steel clamping plate is sandwiched between the isolator wall and the gloveport external ring. A silicone gasket may be required for those applications where the isolator wall is made of glass The tightening action of the Tee-screws compresses the added O ring and the interface plate O ring with a resulting reliable seal Description of mock up A mock up of the above interface was fabricated to prove the concept The gloveport was mounted on a ½ inch thick polycarbonate plate. Installed per manufacturer s instructions A 6mm O ring was bonded to the gloveport outer ring using clear silicone RTV adhesive The interface plate was fabricated of ½ thick clear polycarbonate and a 6mm O ring was bonded to its face to seal up against the gloveport outer ring Pneumatic connections were added to the interface plate to connect ot the GIT-LC tester. Page 4 of 11

5 To simulate the clamping plate, six each 3/8-16 studs were attached to the mounting plate. Cross bars between the studs were used to apply clamping force onto the interface plate. Page 5 of 11

6 2. Gloveport Interface Figure 4. - Mock up of interface Repeated testing of the mock up proved that the design described above is solid in that it will deliver a simple, consistent and reliable interface to the gloveport under test The mock up was attached to the gloveport numerous times and it never failed to produce predictable results after each connection Figure 5.0 shows the Ergoclean gloveport connected to the GIT-LCA glove integrity tester while in operation Figure 6.0 shows the gloveport as modified to accept the gloveport interface. Notice the blue clamping ring that is added to the assembly and features the threaded hole onto which the interface is attached Figure 7.0 shows the interface installed onto the gloveport. Visible are the pneumatic connections to the glove tester and the holding handle to facilitate interface installation. Page 6 of 11

7 Figure 5.0 Page 7 of 11

8 Figure 6.0 Page 8 of 11

9 Figure 7.0 Page 9 of 11

10 3. Gauntlet testing Positive pressure Testing of the single piece gauntlet under positive pressure, meaning that the isolator is under negative pressure for containment applications Two different gauntlet types were tested Hypolon 10 inch gauntlet, color white. Somewhat stiff gauntlet that seems to easily take set, for example folds, pleats. Somewhat smooth outer and inner surfaces Neoprene 10 inch gauntlet, color black. Rubbery material, dull on hand side and shiny and sticky on the isolator side. Very pliable, does not crease easily Issues found Because of the geometry, the main body of the gauntlet continues to expand (stretch) once pressure is applied. As a result, leak testing can only be performed at low pressure values Confining the body of the gauntlet resolves this problem but is not reasonable for positive pressure testing (gauntlet located inside the isolator). On the other hand, it is possible to achieve that in negative pressure mode (gauntlet outside the isolator inside a vacuum chamber). See note on this subject later Because of the low test pressure, the gauntlet s is slow in taking the required stable shape that is necessary for a reliable leak test. A stabilization pressure sequence, at a higher pressure than the leak test pressure, was added to take place before the leak test sequence Process parameters Test Pressure: 350 pa Stabilization Pressure: 420 pa (20% higher than leak test pressure) Leak test flow rate: 50 Sccm Inflation time: 60 seconds approx. (see note 1) Pressure stabilization time: 60 seconds Leak test time: 240 seconds Total leak test time: 360 seconds (6 minutes) Note 1: This time indicates starting from a totally deflated gauntlet. This time can also be greatly reduced by adding an inflating ring to the gloveport interface hardware Performance testing results Claimed orifice size detection capability: 250 um (0.010inch) diameter Confidence level of no false positives: > 3 sigma (99%) Confidence level of hole detection: > 4 sigma (100%) Page 10 of 11

11 Note: The above confidence levels and claimed detection capability are very conservative. The process parameters can be adjusted to slightly reduce the confidence level and achieve either a shorter cycle time or a reduction of the size of the orifice that the system will reliably detect. 4. Gauntlet testing Negative pressure Testing the gauntlet under negative pressure, for aseptic applications that have positive pressure inside the isolator, offers the possibility of drastically improving the system s performance The gauntlet is reversed to the outside of the isolator and placed inside a vacuum chamber The vacuum chamber includes restraining surfaces that conform to the gauntlet body (cone) Restraining surfaces must be of porous material Preliminary testing confirms that much higher pressure levels can be applied to a restrained gauntlet Performance capability should approach that of a standard glove in a cuff/sleeve/glove system 4.6. For reference, such performance is: Orifice detection size: 100 um (0.004 ) diameter Pressurization time: 60 seconds Leak test time: 120 seconds Total leak test cycle time: 120 seconds (3 minutes) 4.7. Development of this type of interface has not been completed at this time. 5. Summary Based on the above, the following points can be made A reliable interface to Carlisle Ergoclean gloveports has been developed and the concept proven Gauntlet testing under positive pressure (isolator negative) can be reliably conducted by the system, given the performance and parameter specification listed above. Page 11 of 11

FlexAct BT (Bag Tester) Validation November, 2015

FlexAct BT (Bag Tester) Validation November, 2015 FlexAct BT (Bag Tester) Validation November, 2015 Agenda 1 Validation Approach and Method 2 Development Case Study 3 Materials Scope of the Validation Point-of-use leak test for Flexboy 2D bags from 50mL

More information

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface Pressure Hulls and Canisters 2 Cornerstone Electronics Technology and Robotics III (Notes primarily from Underwater Robotics Science Design and Fabrication, an excellent book for the design, fabrication,

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

HYGIENIC SIGHT FLOW INDICATORS

HYGIENIC SIGHT FLOW INDICATORS Section: T500 Bulletin: T500.3 Date: 03/16/15 Supersedes: NEW HYGIENIC SIGHT FLOW INDICATORS Installation, Operation, and Maintenance Manual Table of Contents 1. Introduction... 2 1.1. Specification...

More information

tel: fax: web:

tel: fax: web: Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

VINAYAK PHARMA TECHNOLOGY

VINAYAK PHARMA TECHNOLOGY Page 1 Page 2 GENERAL DESCRIPTION Vinayak, Glove Leak Tester is designed for testing integrity of gloves and its sealing with glove port used in various applications. The Gloves are leak tested under the

More information

Electron Microscopy Sciences

Electron Microscopy Sciences Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT 62057-10 Frigimat Cub Dry Ice Maker sgkcck@aolcom PO Box 550, 1560 Industry Road, Hatfield, PA 19440 Safety Symbols Used in this Instruction Manual

More information

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification A Mating Ring B Mating Ring/ Retaining Ring C Mating Ring/ Clamp Ring D Mating Ring Adapter E Primary Ring F Primary Ring/ Retaining Ring G Finger Springs H Spring Retainer I Gland O-ring J Flat Gasket

More information

ANTARES. User Manual ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH. Photo: Jonas Andersson, Lysekil

ANTARES.   User Manual ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH. Photo: Jonas Andersson, Lysekil ANTARES User Manual Photo: Jonas Andersson, Lysekil ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH ANTARES - User manual We want to congratulate you on your purchase of the ANTARES, a Dry Glove System developed

More information

Gluing Guide QCS Oval & Quick Cuff

Gluing Guide QCS Oval & Quick Cuff Gluing Guide QCS Oval & Quick Cuff General information SI TECH has an extensive background and history in the development and design of premium drysuit components that dates back to the early 1960 s. This

More information

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTION ARCHON Industries, Inc Liquid Level Gauges Models: BT-LLG ND-LLG INSTALLATION & MAINTENANCE INSTRUCTION Instruction No.: 1014.2 Revision Issued: 3/01/03 Approved: Engineering Manager Warning ONLY QUALIFIED

More information

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,

More information

PNEUMATIC PRESSURE CONTROLLERS

PNEUMATIC PRESSURE CONTROLLERS PNEUMATIC PRESSURE CONTROLLERS VARIABLE VOLUME PRESSURE CONTROLLER MODELS: V-1 R AND V-2R The 3D Variable Volume Pressure Controller is available for requirements of 0-1,000 psi and 0-6,000 psi in absolute

More information

TURBINE SEAL: AXIAL TYPE DESIGN

TURBINE SEAL: AXIAL TYPE DESIGN TURBINE SEAL: AXIAL TYPE DESIGN Our axial type seals are specifically designed for application to hydroelectric turbines and large water pumps for sewage handling, filtration, irrigation, and more. Our

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

SIMULATED PROOF TESTING OF MORTAR BASEPLATES

SIMULATED PROOF TESTING OF MORTAR BASEPLATES SIMULATED PROOF TESTING OF MORTAR BASEPLATES Andrew G. Littlefield* and Joseph Sibilia US Army RDECOM-ARDEC Benét Laboratories Watervliet, NY 12180 USA Abstract In the current environment there is a need

More information

Portlight Construction

Portlight Construction Portlight Construction Version 2, dated 28 th June 2012 Contents Opening Portlights - Requirements... 2 Opening Portlights Design Parameters... 2 An Opening Portlight Design... 3 Making the Opening Portlight

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC. Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.

More information

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies Tire Inflation Cage Kit 85608214 For servicing only single piece automotive, and most light truck tire/wheel assemblies This is a supplement to your operating manual and covers the setup and use of the

More information

Tightening Evaluation of New 400A Size Metal Gasket

Tightening Evaluation of New 400A Size Metal Gasket Proceedings of the 8th International Conference on Innovation & Management 307 Tightening Evaluation of New 400A Size Metal Gasket Moch. Agus Choiron 1, Shigeyuki Haruyama 2, Ken Kaminishi 3 1 Doctoral

More information

Float valves Types SV 4, SV 5 and SV 6

Float valves Types SV 4, SV 5 and SV 6 Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Brass One-touch Fittings

Brass One-touch Fittings Brass One-touch Fittings Series KQB Fluid temperature: 5 to 0 C Grease-free material: FEP PF Nylon Soft nylon Polyurethane Polyolefin Electroless nickel plated (Brass parts): ade to Order (-X2) K D S Q

More information

Proof of concept of a Bio-Containment System for Mars Sample Return Mission

Proof of concept of a Bio-Containment System for Mars Sample Return Mission Proof of concept of a Bio-Containment System for Mars Sample Return Mission S. Senese (I), P. Magnani (I), A. Fumagalli (I), M. Colomba (I) A. Pedrini (II), D. Indrigo (II), A. Terribile (II), R. Ferrario

More information

VIC offers a variety of Calibrated Gas Leaks

VIC offers a variety of Calibrated Gas Leaks CALIBRATED GAS LEAKS VIC offers a high quality line of calibrated gas leaks traceable to National Institute of Standards Technology (NIST). Calibrated gas leaks are used to provide a controlled delivery

More information

Technical Service Bulletin 10001

Technical Service Bulletin 10001 Technical Service Bulletin 10001 THIS APPLIES TO ALL AIR SPRINGS USED IN USSC LLC AIR SUSPENSIONS Issue: USSC has made a change to the air spring used in operator seat suspensions. This bulletin will identify

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

Model year 2014 USER MANUAL

Model year 2014 USER MANUAL Model year 2014 USER MANUAL WARRANTY Terms and conditions BOS MTB offers warranty on its products on the following terms : BOS MTB guarantees to the original purchaser that the BOS product for which they

More information

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors Journal of Physics: Conference Series Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors To cite this article: D N Prasad et al 2008 J. Phys.: Conf.

More information

Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH.

Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH. Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH www.sitech.se The Oval revolution We want to congratulate you on your purchase of the ANTARES Modular Dry Glove System. The oval design and quick

More information

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing Training for Proofmaster M/S/Automat Functional principle for airtightness testing July 2017 Airtightness measurement 1. Measuring principle 2. Behaviour of the watch under vacuum 3. Behaviour of the watch

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification Low Temperature Design A Spacer Ring B Compression Ring C Retaining Ring D Wave Spring E O-ring F ent/drain Connection G Seat/Mating Ring H Insert I Bellows Assembly J Housing A K Spacer B F G H I C D

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9 Estimated kerf width compensation The widths in the chart below are for reference. Differences between installations and material composition may cause the specific user results to vary from those shown

More information

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M LIQUID LEVEL GAUGE FOR WELDING ZGAU 7 O&M, 77 O&M, 78 O&M, 79 O&M Edition: 07/0 Date: 0.07.0 GO WITH OUR FLOW SPIS TREŚCI. Introduction. Construction. Installation. Installation of liquid level gauge of

More information

Smooth Vent Valve XVD. Series

Smooth Vent Valve XVD. Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

LEAK TROUBLESHOOTING

LEAK TROUBLESHOOTING LEAK TROUBLESHOOTING If you suspect that your TMC isolation system is leaking (most often evidenced by going through air/nitrogen tanks too quickly), this guide will help you to find and fix the problem.

More information

The X-11 Molding Chamber

The X-11 Molding Chamber The User Guide to The X-11 Molding Chamber Table of Contents Overview of Features & Specifications... 3 Features... 4-5 Safety & Maintenance... 6 Initial Startup Procedure... 7 Using the X-11... 8-9 Using

More information

Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids

Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids Maureen Perry, Steve Smalley Northrop Grumman Electronic Systems 7323 Aviation Blvd Baltimore, MD 21240 USA Ph: 410-765-4498

More information

UNIVERSAL MASK TEST SYSTEM

UNIVERSAL MASK TEST SYSTEM f UNIVERSAL MASK TEST SYSTEM Quotation #110811 Automated Motion Inc. 225 NW Victoria Drive Lee s Summit, Missouri 64086-4709 www.automatedmotion.com SYSTEM OVERVIEW AMI s Universal Mask Test System is

More information

Smooth Vent Valve. XVD Series

Smooth Vent Valve. XVD Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION XA9846601 R.S. HART Sheridan Park Research Community, Atomic Energy of Canada Ltd, Mississauga, Ontario D.B. RHODES Chalk River Laboratories, Atomic Energy

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE Prepared by: Pathway Piping Solutions Daniel L. Edgar, PE Pine Valley, Ca 91962 Phone: (619) 473-8248 FAX: (619) 473-8148 Pathway

More information

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport.   «EMIS», CJSC Russia, Chelyabinsk EMIS-VEKTA 1200.UM.PS 27.11.2012 v1.0.5 FLOW CONDITIONER User manual Passport www.emis-kip.ru «EMIS», CJSC Russia, Chelyabinsk Disclaimer "EMIS", CJSC reserves the right to make changes in the design and

More information

Figure 1 Schematic of opposing air bearing concept

Figure 1 Schematic of opposing air bearing concept Theoretical Analysis of Opposing Air Bearing Concept This concept utilizes air bearings to constrain five degrees of freedom of the optic as shown in the figure below. Three pairs of inherently compensated

More information

Homestead Series 820 AWWA Butterfly Valves

Homestead Series 820 AWWA Butterfly Valves Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

UTEX INDUSTRIES, INC.

UTEX INDUSTRIES, INC. UTEX INDUSTRIES, INC. C A R T R I D G E S E A L Externally located springs are virtually non-clogging Visible drive disc indicates face wear Setting clip removal unnecessary saving installation time Single-piece

More information

BPS-2, Rev TABLE OF CONTENTS

BPS-2, Rev TABLE OF CONTENTS BPS-2, Rev. 050404 Bilayer Perfusion System Model BPS-2 125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 fax www.warneronline.com BPS-2, Rev. 050404 TABLE OF CONTENTS

More information

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION ISOLATORS OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION Aseptic Isolators Extract Technology is a leading supplier of containment and aseptic systems for the pharmaceutical and biotech markets. We have

More information

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION ISOLATORS OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION Aseptic Isolators Extract Technology is a leading supplier of containment and aseptic systems for the pharmaceutical and biotech markets. We have

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:... 1 2.1 Regulator

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric

More information

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments

More information

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010 UNITY 2 Uni-DAAMS Manual Version 1.3 (Changes to Section 1.1) March 2010 1. Introduction...2 1.1. Installing the DAAMS tube ovens...2 1.2. Swapping between tube types...5 1.3. Changing tube oven o-rings...6

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements. TIGHTNESS Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements. ODU has the necessary expertise for developing and manufacturing connectors

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS WIDDER TOOLS HPIC-10000-D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS Description: The WIDDER Hydrostatic Test Systems C Series is a portable, selfcontained, air driven hydrostatic

More information

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7 Models 461-S, 461-8S and 461-12S Regulators R-1330 Rev. 7 461-S, 461-8S and 461-12S Regulators The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

CAPILLARY FLOW POROMETER CFP-1500AL. Not just products... solutions.

CAPILLARY FLOW POROMETER CFP-1500AL. Not just products... solutions. CAPILLARY FLOW POROMETER CFP-1500AL Not just products... solutions. PRINCIPLE OF POROMETRY A wetting liquid is allowed to spontaneously fill the pores in the sample and a nonreacting gas is allowed to

More information

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS COMPACT TRIPLE WALL OUTLET STATION MODEL 6255-1 INSTALLATION AND OPERATING INSTRUCTIONS To assure safe operation and conformation to local fire codes, all Porter Outlet Stations are designed to be used

More information

High Altitude Deployment Article By Jim Jarvis Rockets Magazine, June 2011 Edited May 2013

High Altitude Deployment Article By Jim Jarvis Rockets Magazine, June 2011 Edited May 2013 High Altitude Deployment Article By Jim Jarvis Rockets Magazine, June 2011 Edited May 2013 I usually use a CO 2 device for high altitude deployment and it works pretty well. However, in the interest of

More information

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

1. A proper preparation of the cone and other material is inevitable prior to a CPTU test. PREPARATION FOR CPTU Procedure for saturation of a piezocone for CPTU 1. A proper preparation of the cone and other material is inevitable prior to a CPTU test. 2. GeoMil Equipment recommends to saturate

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots SECTION F Introduction ACCESSORIES Switch Guar d s Prevent accidental operation of switches Switch operation limited to selected functions Adaptable to one, two and four pole config u r a t i o n s One

More information

Piloted Non-Return Valves

Piloted Non-Return Valves ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

NP-1 SETUP GUIDE V. 1.1, 11-17

NP-1 SETUP GUIDE V. 1.1, 11-17 SETUP GUIDE V. 1.1, 11-17 SETUP INSTRUCTIONS FOR THE pneupod NP-1 ISOLATION FEET: Thank you for purchasing a pneupod NP-1 pneumatic isolation device. Below is a list of what's in the box along with a description

More information

DL 8 Dome Port. Product Registration. Product Number 75340

DL 8 Dome Port. Product Registration. Product Number 75340 DL 8 Dome Port Product Number 75340 Product Registration Please register your product at ikelite.com within 15 days of purchase. Our product registration database is the best way for us to get a hold of

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

MSA Confined Space Entry Equipment

MSA Confined Space Entry Equipment MSA Confined Space Entry Equipment Because every life has a purpose... MSA Confined Space Entry Equipment MSA XTIRPA Manhole Guard System Use for confined space vertical entry and fall protection when

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Inserta Products, Inc.

Inserta Products, Inc. CODE 6 & 6 -BOLT SPLIT TYPE The INSERTA CODE 6 and CODE 6 -Bolt, Split Flange Type, Modular Connectors, are used in integrated hydraulic systems in place of welded and threaded pipe fittings. These are

More information

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (. 434 Lift-off In-line Zinc can also be 31.5 19.1 (.750) For Lift-Off For on Lift-Off 1300 (300 lbf) 2200 (500 lbf) 56 T.P.I. (2.21) 31.5 19.1 (.750) Tapped hole Ø 9.5 (.375) ultimate 3300 (750 lbf) 9300

More information

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS

More information

Tex-616-J, Construction Fabrics

Tex-616-J, Construction Fabrics Contents: Section 1 Overview... Section s...3 Section 3 Archived Versions...10 Texas Department of Transportation 1 06/00 1/07 Section 1 Overview Effective dates: June 000 December 007. Section 1 Overview

More information

CORESTA RECOMMENDED METHOD N 6

CORESTA RECOMMENDED METHOD N 6 CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination

More information

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS CONTROL VALVES INSTALLATION MANUAL TABLE OF CONTENTS Receiving & Handling 3 Basic Handling Continued 4 Approved Lifting Methods 5 Installing Pressure

More information

OWNER S MANUAL AirTop Large and AirTop Small

OWNER S MANUAL AirTop Large and AirTop Small It is the owner s responsibility to read and understand the material presented in this manual and to instruct all users or operators on how to use product safely. By inflating the product, you hereby agree

More information

Diaphragm pop-pop engine

Diaphragm pop-pop engine Diaphragm pop-pop engine By Jean-Yves Based on some knowledge got from previous engines we decided to build a new one in order to test various diaphragms. Therefore, where the diaphragm is usually pinched

More information