1 Hydraulic & Offshore Supplies Hip Air Operated s YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE
2 Air Operated s High Pressure Equipment Company offers five lines of air operators to accommodate remote operation of pressure valves up to 00,000 psi. Various models of diaphragm and piston operated valves are available in both normally open and normally closed models, and can be controlled by air regulator, electrical solenoid or low pressure manual valve. The Remetco line of air operated metering valves provides remote operation for fine metering applications. Index Page Mini-Hippo Piston Air Operators Hipco Diaphragm Air Operators Remarco Diaphragm Air Operators Hippo Piston Air Operators Remetco Piston Air Operated Fine Metering s R2 2/ 7.
3 Mini-Hippo Piston Air Operators for Remote Operation To 6,000 psi Mini-Hippo Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These piston air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. Air pressure requirement ranges from 0 to 0 psi. The Mini-Hippo air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Mini-Hippo 0- (normally closed) Mini-Hippo 0-2AF6 (normally open) Mini-Hippo 0-AF4 (normally open/ normally closed) " Diameter Piston Air Operators Open (Spring To Open / Air To Close) Maximum Operating Approximate AIr Pressure Pressure to Seat 0-**AF2 6,000 psi psi 0-**AF4 6,000 psi psi 0-**AF6 6,000 psi psi 0-** 6,000 psi psi 0-** 6,000 psi psi 0-**HF 6,000 psi psi Closed (Air To Open / Spring To Close) Maximum Operating Pressure ** Standard Patterns (reference Page.4) Minimum Approximate Approximate Adjusting Air Pressure Air Pressure Screw to Unseat to Fully Torque Open 0-**AF4 6,000 psi in. lb. 0 psi 0 psi 0-**AF6 6,000 psi in. lb. 0 psi 0 psi 0-** 6,000 psi in. lb. 0 psi 0 psi 0-** 6,000 psi in. lb. 0 psi 0 psi 0-**HF 6,000 psi in. lb. 0 psi 0 psi OPTIONS: Stems & Seats... Carbide (for cyclic service) (for cyclic service) Bodies..... Hastelloy C, Hastelloy B Inconel 600, Inconel Incoloy 800, Incoloy Titanium Grade 2, Titanium 6AL4V temperatures from -42 F to,200 F (medium and high Open Closed 7.. R4 2/02
4 Hipco Diaphragm Air Operators for Remote Operation To Hipco Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. The Hipco air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Hipco 0- (normally closed) Hipco 0-2NFB (normally open) Hipco 0-AF4 (normally open/normally closed) OPTIONS: Stems & Seats... Carbide (for cyclic service) (for cyclic service) Bodies..... Hastelloy C, Hastelloy B Inconel 600, Inconel Incoloy 800, Incoloy Titanium Grade 2, Titanium 6AL4V temperatures from -42 F to ,200 F (medium and high Open 6 7 Diameter Diaphragm Air Operators Closed Air Operated s Open (Spring To Open / Air To Close) Maximum Operating Approximate AIr Pressure Pressure to Seat 0-**AF4 0,000 psi psi 0-**AF6 0,000 psi psi 0-**NFA 0,000 psi psi 0-**NFB 0,000 psi psi 0-**NFC 0,000 psi psi F-**NFA,000 psi 8 psi F-**NFB,000 psi 8 psi F-**NFC 0,000 psi 00 psi F-**NFD 0,000 psi 00 psi 20-**LF4 20,000 psi 20-**LF6,000 psi 8 psi 20-**LF 0,000 psi 00 psi 0-** 0,000 psi 0-** 0,000 psi 8 psi 0-**HF 0,000 psi 8 psi 40-**HF 0,000 psi 8 psi 60-** 70 psi 60-** 70 psi 60-**HF 70 psi Closed (Air To Open / Spring To Close) Maximum Operating Pressure ** Standard Patterns (reference Page.4) Minimum Approximate Approximate Adjusting Air Pressure Air Pressure Screw to Unseat to Fully Torque Open 0-**AF4 0,000 psi 20 in. lb. 0 psi 4 psi 0-**AF6 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFA 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFB 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFC 0,000 psi 20 in. lb. 0 psi 4 psi F-**NFA,000 psi 60 in. lb. 80 psi 00 psi F-**NFB,000 psi 60 in. lb. 80 psi 00 psi F-**NFC 0,000 psi 7 in. lb. psi 00 psi F-**NFD 0,000 psi 7 in. lb. psi 00 psi 20-**LF4 20,000 psi 40 in. lb. psi 0 psi 20-**LF6,000 psi 60 in. lb. 80 psi 00 psi 20-**LF 0,000 psi 7 in. lb. psi 00 psi 0-** 0,000 psi 40 in. lb. psi 7 psi 0-** 0,000 psi 60 in. lb. 80 psi 00 psi 0-**HF 0,000 psi 60 in. lb. 80 psi 00 psi 40-**HF 0,000 psi 60 in. lb. 80 psi 00 psi 60-** 0 in. lb. 8 psi 60-** 0 in. lb. 8 psi 60-**HF 0 in. lb. 8 psi High Pressure Equipment Company R4 2/02 P.O. Box Linden Ave. Erie, PA 60 U.S.A. Phone: (84) Fax: (84) sales@highpressure.com 7.2
5 Remarco Diaphragm Operated s for Remote Operation To 00,000 psi Remarco air operated valves are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm operated valves provide remote operation up to 00,000 psi by means of an air input supply ranging from 2 to 0 psi to the air actuator. An electrical solenoid valve for the air supply is provided with all Remarco valves and is mounted directly to the valve. The standard solenoid is 20 volt, 60 cycle, watts with NPT air inlet. (Other voltages available at additional charge consult factory). The solenoid is normally closed and when energized allows air into the diaphragm casing to activate the valve. In the event of an electrical or air line failure, the valve will return to its normal position. The Remarco valve features removable stem seats. bodies are 6 stainless steel. stems are hardened 7-4PH stainless steel. Standard packing on the 0,000 psi and Remarco valves is Teflon O-ring with Buna-N, Viton, or Silicone, available at no additional cost. Open 7 Diameter Diaphragm Air Operators Closed Open (Spring To Open / Air To Close) D0R2LFR D20R2LFR D0R2R D0R2R D0R2HFR D0R2HFR D60R2R D60R2R D60R2HFR D00R2XF4R D00R2XF6R Maximum Operating Pressure 0,000 psi 20,000 psi 0,000 psi 0,000 psi 0,000 psi 0,000 psi 00,000 psi 00,000 psi 7 psi psi psi psi 0 psi 0 psi Closed (Air To Open / Spring To Close) SD0R2LFR SD20R2LFR SD0R2R SD0R2R SD0R2HFR SD0R2HFR SD60R2R SD60R2R SD60R2HFR SD00R2XF4R SD00R2XF6R 0,000 psi 20,000 psi 0,000 psi 0,000 psi 0,000 psi 0,000 psi 00,000 psi 00,000 psi 40 ft. lb. 0 ft. lb. 0 ft. lb. psi 70 psi psi 0 psi 0 psi 0 psi 8 psi 8 psi 0 psi 0 psi 7 psi 7 psi 7 psi 0 psi 00 psi 00 psi /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" LF LF HF HF HF XF4 XF6 LF LF HF HF HF XF4 XF6 /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6".08" Tubing Approximate Connections Size Air Pressure Orifice to Seat O.D. I.D. Approximate Approximate Tubing Maximum Lock Nut Air Pressure Air Pressure Connections Size Operating Torque to Unseat to Fully Orifice Pressure Setting Open O.D. I.D. OPTIONS: /6" /6" /6" /6" /6" /6" /6" /6".08" /6" /6" /6" /6" /6" /6" Stems & Seats... Carbide (for cyclic service) Bodies..... Hastelloy C, Hastelloy B Inconel 600, Inconel Incoloy 800, Incoloy Titanium Grade 2, Titanium 6AL4V temperatures from -42 F to,200 F (medium and high 7. R4 2/02
6
7 Remetco Piston Operated Fine Metering s For Liquids or Gases Precise control with fast response is possible in fine metering applications to with Remetco s. Pinpoint accuracy and repeatability are assured by a unique stem travel control device working in concert with a Conoflow operator, which is actuated by an input air pressure on only psi. Body material is Type 6 stainless steel, with both stem and removable seat of 7-4PH. The stem tip is ground to a included taper, with orifice sizes as listed in the ordering table. Installation requires only connection to an air supply of 20 to 00 psi. This is connected both to the supply air connection and to the instrument air inlet. The latter is regulated between and psi to actuate the valve to the desired position. Regulation is effected by the user s instrument or by the optional instrument panel at lower left. Thus the valve is in its full open position with a psi air input and in the closed position with a psi air input. Failsafe operation. In standard configuration, the valve OPENS upon failure of the air supply. It may also be supplied to close upon air failure, to open upon an increase in air signal, or any combination of these specifications. Remote Positioner RVP. Optional instrument panel shown at bottom can be ordered as an accessory. It is a manually operated remote air signal valve positioner which permits positioning the stem at any desired point within the travel of the stem. The dial indicator is graduated into 00 increments; thus each dial increment moves the stem 0.02". Standard inlet and outlet connections to the Remetco are for /6" OD coned and threaded tubing. Adapters may be supplied for other tubing sizes upon request. Shutoff not recommended. While this valve is capable of on-off operation, it is designed as a fine metering instrument. To assure maximum stem life, a manual on-off valve should be used in the line upstream of the Remetco. To order, use assembly number in table and specify if operation is to be other than the standard closure upon air failure. Add RVP as suffix if remote air signal valve positioner is desired. Ordering Table Assembly Pressure Orifice Number Rating Size 0M-2HFR 0,000 psi 0M-2HFR 0,000 psi 60M-2HFR /6" OPTIONS: Stems & Seats... Carbide (for cyclic service) Bodies..... Hastelloy-C, Hastelloy B Inconel 600, Inconel Incoloy 800, Incoloy Titanium Grade 2, Titanium GAL4V temperatures from -42 F to,200 F (medium and high 7" 22" Remote Stem Positioner RVP above permits remote positioning of valve stem in increments of 0.02". To order, add suffix RVP to base order number. 7.4 R2 2/
Index 7.1. Page R2 12/99
High Equipment Air Operated s High Equipment Company offers five lines of air operators to accommodate remote operation of pressure valves up to 00,000 psi. Various models of diaphragm and piston operated
More informationIndex 7.1. Page R2 12/99
High Equipment Air Operated s High Equipment Company offers five lines of air operators to accommodate remote operation of pressure valves up to 00,000 psi. Various models of diaphragm and piston operated
More informationGeneral Information valve design valve selector guide catalog numbering system warranty terms
CERTIFIED High Equipment Table of Contents 2 eneral Information valve design valve selector guide catalog numbering system warranty terms Low Valves, Fittings and Tubing - 0,000 and 5,000 psi service Taper
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More informationHigh Pressure Equipment Medium Pressure Valves, Fittings and Tubing
igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationSpecialty Products. Specialty Products Index
Specialty Products MAXIMATOR has been designing and manufacturing specialty products to serve the high pressure market for over thirty years and has a worldwide reputation for quality and reliability.
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationHigh Pressure Equipment Pressure Vessels and Reactors Index
Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard
More informationCVI Valve Line. Exceeds the industry s highest standards for reliability and performance
CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI
More informationGo to Table of Contents. Ball and Plug Valves
Ball and Plug s July 2014 Series s Parker series manually, pneumatically and electrically actuated two-way and three-way ball valves are designed for 1/4 and 1/2 turn media shutoff or switching applications
More informationBall Valves Subsea Series
Ball Valves Subsea Series Internal Pressures to 20,000 psi (1379 bar) Water Depths to 12,500 ft (3810 meters) Autoclave Engineers subsea ball valves have been designed to fulfill the ever growing demand
More informationHigh Pressure Equipment 2 - Medium Pressure Valves, Fittings and Tubing 20,000 psi service
Solutions de régulation des fluides High Pressure Equipment 2 - Medium Pressure Valves, Fittings and Tubing 20,000 psi service Petrometalic SA 2, rue de l Ermitage 78000 VERSAILLES www.petrometalic.com
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-150
Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationChlorinator. MODEL C-731 (Floor Mounted)
Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationControl Valve : The Final Control Element. Nimish Shah
Control Valve : The Final Control Element Nimish Shah VALVES How to select Control Valve??? selection parameters for the valve : size, material of construction, pressure and temperature ratings, and End
More informationBULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.
BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately
More informationChoosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
More information1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG
A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationCASH VALVE TYPE KP BACK PRESSURE VALVES
A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or
More informationModel 1800 PFM Series Regulator. Technical Bulletin
Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane
More informationBrooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900
Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900 Model FC 8800 Flow Controller Model 1350/55 with FC 8900
More informationTHE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691
THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationMANUAL BE SERIES Test Benches
The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES
More informationHigh Pressure Check Valves
High Pressure heck Valves Pressures to 60,000 psi (4137 bar) O-Ring heck Valves Minimum operating temperature for standard o-ring check valves 0 F (-17.8 ). For low temperature option to -423 F (-252 )
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More information36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
More informationPressure Sensing Valve - Model 4023
Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge
More informationMEGR-1627 Instruction Manual
MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm
More informationSafety Blocks Brochure
Hydraulic & Offshore Supplies Safety Blocks Brochure YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE FAWCETT CHRI STI E Safety Block s Carbon
More informationCFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)
MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control
More informationBuying more than 11 gauges? Call Lesman for additional discounts.
Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationPneumatic Powered - Plunger Pumps
Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationMEGR-1912 Instruction Manual
MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More information1800CPB2 Service Regulators
SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,
More informationInstructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.
027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782
More informationTotal Pressure Regulator Solutions.
Total Pressure Regulator Solutions www.pressure-tech.com Working with customers to support their exact needs A pressure regulator is a critical component in any fluid control system. At Pressure Tech,
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More information1800CPB2 Pilot-Loaded Service Regulators
1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................
More informationSeries 100 Slam Shut Valve. Technical Bulletin
Series 100 Slam Shut Valve Technical Bulletin 02 Elster The Series 100 Slam Shut protects gas installations against overpressure conditions by automatically shutting off the gas flow. General Information
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationBrooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900
Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Features and Benefits Flow controllers for high pressure
More informationOperation Manual Piston Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:
More informationProportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves
More informationSolenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationSeries 2G Diaphragm Actuators
Series 2G Diaphragm Actuators Precise Control: Operates valves in on/off, throttling or proportioning systems Series 2G diaphragm actuators are designed for on/off or throttling control of Norris angle-disc
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationType 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls
Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationGeneral. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes
DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay
More informationOperation Manual. Diaphragm Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationHydrogen Valves, Fittings and Tubing
Hydrogen Valves, Fittings and Tubing utech is a leading brand of high-pressure valves, fittings and tubing designed to meet the critical requirements of today s most severe applications. We prove our commitment
More informationSchroeder Check Test Point System
Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000
More informationModels: C62/63/64-A/D
Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationPressure Equalising Valves Model , for Differential Pressure Gauges
Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to
More informationSuggested Installation & Operating Instructions for Sidewinder Pumps
Model 164 C P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pump Suggested Installation & Operating Instructions for Sidewinder
More informationINSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator
INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As
More informationPetro-Chemical & Analyzer Sampling Systems
Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer
More informationINSTRUMENTATION VALVES
INSTRUMENTATION VALVES INSTRUMENTATION BALL VALVES INTEGRAL-BONNET NEEDLE VALVES TOGGLE VALVES (TG Series) CHECK VALVES (CHV Series: For General Industry) RELIEF VALVES (RVL/RVH Series) INSTRUMENTATION
More informationProduct Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction
Product Manual CVS Type 1301F and CVS Type 1301G Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationPetro-Chemical & Analyzer Sampling Systems
Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More informationSG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)
TECHNICAL INFORMATION BuTech designs all pressure-containing equipment to meet or exceed the applicable requirements of Section VIII, Division1 or Division 2 of the ASME Boiler and Pressure Vessel Code
More informationJR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE
JR Series Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE The LowFlow JR Series line of high pressure regulators have the ability to handle very high pressures and very low flows. These valves
More informationType 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator
January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity
More informationModels 461-S, 461-8S and S Regulators. R-1330 Rev. 7
Models 461-S, 461-8S and 461-12S Regulators R-1330 Rev. 7 461-S, 461-8S and 461-12S Regulators The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationModel 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG
A C E D SB 8551.3 Model 1800 PFM Series Regulator For Constant Precise Fixed Factor Measurement From 0.5 to 30 G AMC Quality System QMI is Accredited by: C R E D I T ISO 900 Registered R E ANSI RAB G I
More informationINDUSTRIAL EXCESS ESS FLOW VALVES
INDUSTRIAL EXCESS ESS FLOW VALVES H-911 SERIES FEATURES n Stainless Steel Construction n MAWP 6000 psi (413 bar) n MAWT 400 F (204 C) n Variable connection sizes (1/8 to 1/2'' & 6 to 12mm) n Cv = 0.5 ;
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationType ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002
Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact
More informationInstruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869
Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869-1 - 115.6020.15 These instructions describe the installation, operation and maintenance of the subject equipment.
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationSection 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index
Section 3000 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR...36 Versatile type of lubrication able to feed liquid to elevated, distant or inaccessible points. CONVEYOR CHAIN LUBRICATION SCHEMATIC...39
More informationGILMONT ACCUCAL FLOWMETERS
OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationPressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
More informationPropor tional Re lief Valve s
www.swagelok.com Propor tional Re lief Valve s R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections Proportional Relief Valves
More informationVESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES
VS Series VESSEL & REACTOR VALVES SPRAY & RINSE VALVES PROCESS VALVES CLEANING VESSELS OR REACTORS WITHOUT OPENING TO ATMOSPHERE Spray & Rinse Valves Code: VRR-VRS Automatic models use an electric or air
More information