Facilities Design Shift Horizontal Equipment in Oklahoma Scott King

Size: px
Start display at page:

Download "Facilities Design Shift Horizontal Equipment in Oklahoma Scott King"

Transcription

1 Facilities Design Shift Horizontal Equipment in Oklahoma Scott King

2 Facilities Review in Oklahoma Identified areas for improvement Design criteria is outdated for play types Vertical separation, cannot sustain a varied, nimble, and adaptable process flow Criteria for justifying vertical equipment What are we going to solve? Liquids rich plays demand alternative solutions Do we need to change? 2

3 Current Design: Vertical Separation Most commonly used in midcontinent Historically relevant in Mid Continent due to gas plays Footprint was of design importance Readily available with fabricators Sub-optimal with higher liquid volumes 3

4 Change in Design Horizontal Separation Increase liquid handling Efficient and longer retention time Sufficient gas handling with pressure control With proper controls and operation, rental flowback equipment can be minimalized Reduced separator sizing Horizontal Heater Treater Heating element in oil phase Efficient emulsion control 4

5 Basic Horizontal Separator Design Criteria Flowback Elimination 500 PSIG MAWP Mechanical Dumps Sand Pan Multiple Solid Drains Clean Out Ports Weir (18 height) Direct inlet 5

6 Basic Horizontal Heater Treater Design Criteria Mechanical Dump No adjustable water leg 125 PSIG MAWP Multi-stage separation capabilities Additional oil residence time Sales/Tank/VRU gas flow Volume specific 6

7 Flowback System Engineered Design Ideals Minimal fittings and elevation changes downstream of choke Utilize swab choke for repairs Minimal rental iron 7

8 Equipment Layout 10ft. 7ft. 50ft. 65ft. Perpendicular Layout Simplified piping Spacing requirements Construction Efficiencies in cost and time Meters 8

9 Change in Construction Horizontal Process Equipment Larger footprint All devices at ground level Spacing still important Need at least 15 psig to push fluids to storage Develop strategies of equipment placement Parallel or Perpendicular 9

10 Change in Flowback Chokes at equipment 30 days of flowback rental equipment Only utilize plug catcher, sand separator, frac tank, and minimal piping Multiple flow regimes through process equipment Frac tank hookup in swab line Ability to move all flow through either swab choke 10

11 Fra c T ank Fi tting Full Process Flow Diagram (PFD) Horizontal EQ (Flowback) Initial Process Flow Diagram (PFD) Move scrubber here to take advantage of pressure drop, cool gas, and possibly remove excess chemical? Straddle BPV? Install a P Trap? P trap with BPV Straddle If LP is low, can take gas from upstream of BPV 3/8" SS Tubing To SSV To Flare Supply ¼ NPT Piping To VRU Supply 1" Sch. 40 To Heat Trace 1" Sch. 40 To Heater Treater Scrubber 1" PSV 125 PSIG Blowdown 3" Sch. 40 Make 4" Sch. 40 for H2s Treating? Kimray 330 SGT- BP MRO Chk Meter Skid 3" BPV Midstream Meter Skid To Compressor From Compressor From VRU Custody Transfer 3/8" SS Tubing To LPS Oil Dump 1" Sch. 40 SSV 1-13/16" 10,000 PSIG 3" Sch. 160 Welded Flowline Buried Flowback Choke Swab Choke Which Valve? 3" Sch "x10' 500 MD (H)LPS Clean out flange 3" PSV 250 PSIG Kimray 850 HUTA Kimray Kimray CBA 250 CBA 250 SOA SOA Recirc line Fitting From Supply Can run line to sales with BPV set to open to tanks / 100 psig To VRT or Tanks 48"x20' 125 MD (H)HT Kimray 212 SGT- BP Blowdown 2" PSV 125 PSIG Kimray 850 HUTA From Supply Dump From From VRU Compressor Compressor Dump Dump Drain Kimray CBA 250 SOA Kimray CBA 250 SOA From VRT To VRT 4" Pressure (6 oz.) / Vacuum Relief (- 0.4 oz) Valve (Enardo) 8 oz./- 0.4 oz. 8 oz./- 0.4 oz. 8 oz./- 0.4 oz. 4" Sch. 40 Vent From Heater Treater / VRT 500 BBL Water Tank 500 BBL Oil Tank 500 BBL Oil Tank To Flare Inlets and gas outlets are planned to be 4" threaded couplings Liquid dumps/drains are 2" threaded couplings Dump controllers are planned to be mechanical Heater treater will be 125 psig to possibly sell gas if line pressure is low enough Move fuel scrubber to downstream of BPV? Or straddle BPV with two 1" fittings Flow- back operations: Utilize flow- back choke, divert through swab choke to repair flow- back choke, routinely drain LPS. 4" or 6" Clean out flanges will be placed in LPS to assist in cleaning potential solids from separator. Recirc line Fitting From Flare Dump Rev. 0: Create PFD 11

12 Initial Layout and Piping 12

13 Flowback - Current Set Up Flowback Setup (A) Equipment Requirements (1) 2" Double Buster Flowback Tank (245') 2" 1502 Piping Sand Separator Hookups Choke Manifold 1 (27) 2" Plug Valves (2) 15K Choke Manifolds (65) Hobbles Piping Legend 3" " 1502 Plug Catcher Choke Manifold PSIG Test Separator Safety Valve GB GB 2" Double Buster Flowback Tank (30 ) 3" 1502 Piping (1) 3" Double Plug Catcher w/ screen (15K; ¼ holes) (1) Safety Valve (1) 1440 PSGI 3-Phase Test Separator MRO Owned Spill Mats (Separate Bid) 13

14 Flowback - New Set Up Equipment Requirements (50') 2" 1502 Piping (12) 2" Plug Valves Piping Legend 3" " 1502 MRO Owned 3" Sch. 160 Flowback Choke Plumb to Swab Line 500 psig MD Horizontal Sep. (50) Hobbles (30 ) 3" 1502 Piping (1) 3" Double Plug Catcher w/ screen (15K; ¼ holes) (2) 3" Gate or Plug Valves (1) 2 Double Buster Flowback Tank Plumb to Frac Tank Plug Catcher Swab Choke 2" Double Buster Flowback Tank 14

15 Questions? 15

CHE Well Testing Package/Service:

CHE Well Testing Package/Service: CHE Well Testing Package/Service: CHE delivers well testing package And services, trailer mounted well testing package and offshore/onshore well testing services with over 10 years experience. Our testing

More information

W E L L S I T E S E R V I C E S

W E L L S I T E S E R V I C E S WELL SITE SERVICES TABLE OF CONTENTS OF CONTENTS WELLTESTING Well Testing Locations...WT-1 VAMP System...WT-2 Combination Test Unit...WT-3 Jumbo Test Unit...WT-4 500 psi Test Separator...WT-5 1,400 psi

More information

In addition to this SOP, the policies and procedures of each operating company will be strictly observed by Rockwater personnel.

In addition to this SOP, the policies and procedures of each operating company will be strictly observed by Rockwater personnel. SOP FB-10 (Revised MAR 2014) STANDARD OPERATING PROCEDURES-FLOWBACK Test Separator Operations Section 1.0 Introduction and Background Rockwater Energy Solutions, Inc. (and all its affiliated and subsidiary

More information

SECTION P4 SEPARATION SYSTEMS

SECTION P4 SEPARATION SYSTEMS SEPARATION SYSTEMS The H.P. Separation System begins with the H.P. Production Header (GAY-1000). This header directs flow to the H.P. Production Separator (MBD-1000). Gases from the H.P. Production Separator

More information

Improving Performance of Gas Lift Compressors in Liquids-Rich Gas Service

Improving Performance of Gas Lift Compressors in Liquids-Rich Gas Service 2019 Artificial Lift Strategies for Unconventional Wells Workshop Cox Convention Center, February 11-14, 2019 Improving Performance of Gas Lift Compressors in Liquids-Rich Gas Service Will Nelle Bill Elmer,

More information

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson OGA SEMINAR DECEMBER 3, 2012 OGA Seminar 2012 2 Regulators Meters Valves Flanges

More information

SHOP WELDED TANKS STANDARD CONNECTIONS

SHOP WELDED TANKS STANDARD CONNECTIONS STEEL WELDED TANKS Tanks are constructed using 3/16 and ¼ inch A36 material. Welding and testing are performed according to API 12F specifications. Shop welded tanks are also available in special sizes

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

Digester Processes. 1. Raw Sludge Pumping System

Digester Processes. 1. Raw Sludge Pumping System Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters

More information

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES Lamar Jones Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 INTRODUCTION The purpose of this paper will be to compare a plug

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

New Developments and Special Experiences in Geoinform s Well Testing Services

New Developments and Special Experiences in Geoinform s Well Testing Services New Developments and Special Experiences in Geoinform s Well Testing Services Peter Baranyi Chief Engineer, GEOINFORM Ltd. Services provided by Geoinform, Well Testing Technologies Surface WT: standard

More information

OIL AND GAS SEPARATION DESIGN MANUAL

OIL AND GAS SEPARATION DESIGN MANUAL OIL AND GAS SEPARATION DESIGN MANUAL BY C. RICHARD SIVALLS, P.E. SIVALLS, INC. BOX 2792 ODESSA, TEXAS 79760 All rights reserved. This publication is fully protected by copyright and nothing that appears

More information

FRAC FLUIDS AND WATER USAGE Evaluating The Commercial Viability and Success In Using Water-Free Fracs

FRAC FLUIDS AND WATER USAGE Evaluating The Commercial Viability and Success In Using Water-Free Fracs FRAC FLUIDS AND WATER USAGE Evaluating The Commercial Viability and Success In Using Water-Free Fracs Overview of Presentation BlackBrush Oil & Gas Natural Gas Liquids (NGLs) as frac fluid. Advantages

More information

Caltec. The world leader in Surface Jet Pump (SJP) and compact separation systems for upstream oil and gas production enhancement

Caltec.   The world leader in Surface Jet Pump (SJP) and compact separation systems for upstream oil and gas production enhancement Caltec brings simple passive technology that enables oil and gas operators to harness the kinetic energy of the production process to enhance their production, extending economic field life and reducing

More information

ONSHORE GAS GATHERING FAQS

ONSHORE GAS GATHERING FAQS ONSHORE GAS GATHERING FAQS These Frequently Asked Questions (FAQs) are intended to clarify, explain, and promote better understanding of the gas gathering line rules. These FAQs are not substantive rules

More information

Safety Selector Valves Dual Pressure Relief Device System

Safety Selector Valves Dual Pressure Relief Device System ANDERSON GREENWOOD Features and enefits Provides a safe, efficient method of switching from an active pressure relief device to a standby, maintaining system overpressure protection regardless of Safety

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

APPENDIX C TANK BATTERIES

APPENDIX C TANK BATTERIES C-i APPENDIX C TANK BATTERIES C - 1. Understanding the Tank Battery. 1. Openings to Vessels for Lines. 2. The Shape and Purpose of Vessels. 3. From the Well to the Tank Battery. C-1 The Lease Pumper s

More information

SEPARATION SYSTEMS. Separator (MBD-1600) or the Wet Oil Tank, (ABJ-1800). Water is

SEPARATION SYSTEMS. Separator (MBD-1600) or the Wet Oil Tank, (ABJ-1800). Water is SEPARATION SYSTEMS The L.P. Separator (MBD-1600) is a 3-phase separator that receives bulk production from the L.P. Header (GAY-1500), I.P. Separator Oil dump and the H.P. Separator Oil Dump. Gas is discharged

More information

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For

More information

NORMAL OPERATING PROCEDURES Operating Parameter Information

NORMAL OPERATING PROCEDURES Operating Parameter Information Operating Parameter Information Each operator performing the normal operating procedures (routine checks) of the facility should be familiar with the current normal operating parameters of all systems

More information

Filter Housings. Universal & Compact Multi-Chamber Filter Housings

Filter Housings. Universal & Compact Multi-Chamber Filter Housings Filter Housings engineer approved Universal & Compact Multi-Chamber Filter Housings White Knight dual- and quad-chamber filter housings fit standard filter cartridges offered by major suppliers. They provide

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING GAS BACK PRESSURE NON VENTING APPLICATION: Vent lines or pressure regulation on separators, heater treaters, compressor stations, gas gathering and distribution systems where it is desired that no gas

More information

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146 PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT Purpose STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146 This paper is designed to serve as an update to the paper formally

More information

Frequently Asked Questions Directive 056 Facilities Technical

Frequently Asked Questions Directive 056 Facilities Technical Frequently Asked Questions Directive 056 Facilities Technical October 2017 This document clarifies and supports some of the technical requirements related to Directive 056: Energy Development Applications

More information

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT Introduction Stormy Phillips Product Manager Legacy Measurement Solutions 9726 East 42nd Street Suite 219 Tulsa, OK 74126 The condition of gas as it

More information

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure PRESSURE REGULATOR PRESSURE REDUCING APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure PRESSURE RANGE: Ductile Iron: Upstream: psig to 125

More information

Slug Catchers Engineered Solutions to Separation Problems

Slug Catchers Engineered Solutions to Separation Problems Slug Catchers Engineered Solutions to Separation Problems Separation Products from Taylor Forge Taylor Forge Engineered Systems has been a leading manufacturer of liquid separation equipment for the pipeline

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents Owner: HSE Performance Assurance ALL HSE PRC 172 Approved By: Manager, HSE Performance Assurance Retention Code: CG01 CA Revised: March 2015 Review Frequency: Five years or less Table of Contents 1.0 Purpose...

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

New Single Well Gas Lift Process Facilitates Fracture Treatment Flowback

New Single Well Gas Lift Process Facilitates Fracture Treatment Flowback Gas Well Deliquification Workshop Sheraton Hotel, February 23-26, 2009 New Single Well Gas Lift Process Facilitates Fracture Treatment Flowback William G. Elmer, P.E. EOG Resources, Inc. Introduction Current

More information

First Stage Regulators

First Stage Regulators DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to

More information

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1. According to NFPA 99, SCFM is an acronym for. a) Surface Conditions at Fahrenheit Mercury b) Standard Conditions

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology Jim Woodard Vice President of Sales Bryant Woods Lead Project Engineer 4/3/18 Page 1 Objectives Impact

More information

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters ABB MEASUREMENT & ANALYTICS WHITE PAPER Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters Remote seals protect transmitters when measuring difficult

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Precision Rotary Airlocks and Diverter Valves

Precision Rotary Airlocks and Diverter Valves Precision Rotary Airlocks and Diverter Valves Utilizing over 40 Years of Mac Process Bulk Material Conveying Technology Airlocks and Diverters Schenck Process offers a wide range of airlocks and diverter

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

Natural Gas Conditioning Skids & Equipments

Natural Gas Conditioning Skids & Equipments Natural Gas Conditioning Skids & Equipments NATURAL GAS CONDITIONING SKIDS NIRMAL has rich experience of supplying complete package of Natural Gas conditioning skids consisting of emergency shut down,

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

Product Overview A DIVISION OF MARSH BELLOFRAM

Product Overview A DIVISION OF MARSH BELLOFRAM Product Overview P627 & P630 P627 Available with internal relief device - R627 version P627 & P630 - High Flow Regulators The P627 and P630 are spring loaded, direct-operated regulators for both low and

More information

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Vaporizer Piping Liquid Chlorine Manifolds

Vaporizer Piping Liquid Chlorine Manifolds T #1 = 1234 1 1 Vaporizer Piping iquid Chlorine anifolds Vaporizers are used for high capacity chemical feed applications when direct gas withdrawal systems are impractical. This document will provide

More information

Owner: USA Division P3 Project Revision No: 00 Date last revised: 08/15/2013

Owner: USA Division P3 Project Revision No: 00 Date last revised: 08/15/2013 Flowback and Sand Management Standard Operating Procedure SOP Owner: USA Division P3 Project Revision No: 00 Date last revised: 08/15/2013 1.0 Applicability This practice applies to all Encana Oil & Gas

More information

White Paper. Electrical control valve actuators on oil and gas production separators

White Paper. Electrical control valve actuators on oil and gas production separators White Paper Electrical control valve actuators on oil and gas production separators Electrical control valve actuators on oil and gas production separators White Paper 18 th August 2014 Electrical control

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Yutaek Seo. Subsea Engineering

Yutaek Seo. Subsea Engineering Yutaek Seo Subsea Engineering Inlet receiving Gas and liquids that enter the gas processing facilities pass emergency shutdown valves, and then go to inlet receiving, where condensed phases drop out. Gas

More information

Offshore Equipment. Yutaek Seo

Offshore Equipment. Yutaek Seo Offshore Equipment Yutaek Seo Flash Gas Compressor (East spar) Dehydration NGL recovery Slug catcher Separator Stabilization Booster compressor Gas export compression (Donghae-1 Platform) May 7 th Gas

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Hydrotherapy Jets System for a Fiberglass Pool

Hydrotherapy Jets System for a Fiberglass Pool Page 1 of 5 Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 6 - Female slip/female slip unions 2 - Female slip/fpt union

More information

PRODUCTION I (PP 414) ANALYSIS OF MAXIMUM STABLE RATE AND CHOKES RESOLVE OF OIL WELLS JOSE RODRIGUEZ CRUZADO JOHAN CHAVEZ BERNAL

PRODUCTION I (PP 414) ANALYSIS OF MAXIMUM STABLE RATE AND CHOKES RESOLVE OF OIL WELLS JOSE RODRIGUEZ CRUZADO JOHAN CHAVEZ BERNAL PRODUCTION I (PP 414) SUBJECT: ANALYSIS OF MAXIMUM STABLE RATE AND CHOKES RESOLVE OF OIL WELLS BY: JOSE RODRIGUEZ CRUZADO JOHAN CHAVEZ BERNAL PROFESSOR MSc. LUIS ANTONIO DEL CASTILLO DE RODRIGUEZ LIMA,

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e. MU047: Practical Valve Technology: Selection, Installation, Upgrading, Inspection & Troubleshooting MU047 Rev.002 CMCT COURSE OUTLINE Page 1 of 7 Training Description: This five-day intensive course covers

More information

ADAPTABILITY & PRECISION

ADAPTABILITY & PRECISION ADAPTABILITY & PRECISION CALIBRATION GAUGES FOR CHEMICAL INJECTION SYSTEMS by KENCO FEATURING NEW AccuRate PRECISION PUMP SETTING GAUGE visit our online business center at: www.kenco-eng.com 2 AccuRate

More information

GAS COMPRESSION SYSTEM

GAS COMPRESSION SYSTEM GAS COMPRESSION SYSTEM The gas compression system at HI 376 A consists of two natural gas turbine-driven Compressors (CBA-4020/4070). Both Compressors are needed for the volume of gas being compressed.

More information

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS

More information

Chlorine Supply Containers And Piping

Chlorine Supply Containers And Piping Chlorine Supply Containers And Piping Containers Chlorine is packaged in containers as a liquefied gas under pressure, resulting in the container having both a liquid phase and a gas phase. When removing

More information

MRO Oil-Air Ratio Regulator

MRO Oil-Air Ratio Regulator MRO Oil-Air Ratio Regulator MRO-1 Edition 07-08 Wide capacity range Requires constant oil supply at 45-65 psig (310-450 kpa) Provides automatic and simple method of maintaining air/oil ratio Wide turndown

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

GAS DEHYDRATION SYSTEM

GAS DEHYDRATION SYSTEM GAS DEHYDRATION SYSTEM High pressure gases from the Gas Compressors (CBA-4070/4020) flow to the Glycol Contactor (MAF-1150). In the Contactor, gas flows through trays, contacting the lean glycol that is

More information

Pressure Compensating (PC) Spray Stakes

Pressure Compensating (PC) Spray Stakes N E T A F I M U S A Pressure Compensating (PC) Spray Stakes Automated Watering Systems for Large Container Production Improve Plant Quality and Conserve Resources 1 or More Good Reasons to Choose Netafim

More information

SURFACE JET PUMP TECHNOLOGY TO INCREASE OIL & GAS PRODUCTION.

SURFACE JET PUMP TECHNOLOGY TO INCREASE OIL & GAS PRODUCTION. THE APPLICATIONS OF SURFACE JET PUMP TECHNOLOGY TO INCREASE OIL & GAS PRODUCTION D Nj B Clt Dr. Najam Beg, Caltec Contents 1. Jet pump principle of operation 2. Design and performance of jet pumpsp 3.

More information

A LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS

A LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS A LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS Jay Miller Sales Manager Production Lift Companies Inc. Artificial Lift & Production Congress January 29, 2019 Unconventional Wells

More information

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM Faculty of Chemical Engineering CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM SUBMISSION DATE: 1 OCT. 2012 Question 1 Name the following equipments based on standard P&ID

More information

Quick Start SunPump Install

Quick Start SunPump Install Quick Start SunPump Install Make A Plan Visualize the complete install. The first step is to commit a plan to paper by a simplified sketch. Where is the best location for the Panels? What is the preferred

More information

Captains Meeting 2009 Introduction to Well Testing- Expro. Edwin Schoorl

Captains Meeting 2009 Introduction to Well Testing- Expro. Edwin Schoorl Captains Meeting 2009 Introduction to Well Testing- Expro Edwin Schoorl Agenda Oil and Gas presence Well construction Well testing Welltest System Welltest Equipment Welltest Video Questions Oil and gas

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas

More information

Tube rupture in a natural gas heater

Tube rupture in a natural gas heater Tube rupture in a natural gas heater Dynamic simulation supports the use of a pressure safety valve over a rupture disk in the event of a tube rupture HARRY Z HA and PATRICK STANG Fluor Canada Ltd A fast

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item: This ballot covers the following item: API 520 Part I 10 th Edition Ballot Item 2.1 2008 12 Modify guidance to PRV datasheets (Line 17) to assist user s with determining the temperature to use for selecting

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal Welcome to the LESER Seminar, Taipei 28. June 2006 1 Design of safety relief valves 2 Design of safety valves Target Classification of Pressure Relief Devices General design of Safety Relief valves 3 Design

More information

SEPARATION SYSTEMS. The Separation Systems consists of the Test Header (GAY-0302) and the Test Separator (MBD-4501).

SEPARATION SYSTEMS. The Separation Systems consists of the Test Header (GAY-0302) and the Test Separator (MBD-4501). SEPARATION SYSTEMS The Separation Systems consists of the Test Header (GAY-0302) and the Test Separator (MBD-4501). The Header System is designed to collect and direct the well stream to the corresponding

More information

HIGH PRESSURE CONTROL VALVES

HIGH PRESSURE CONTROL VALVES METERING VALVE APPLICATIONS: This valve can be used to meter or control flow of liquids and/ or gases on meter runs, flow lines, or may be used as a choke under low pressure drop conditions where freezing

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

Fundamentals Of Petroleum Engineering PRODUCTION

Fundamentals Of Petroleum Engineering PRODUCTION Fundamentals Of Petroleum Engineering PRODUCTION Mohd Fauzi Hamid Wan Rosli Wan Sulaiman Department of Petroleum Engineering Faculty of Petroleum & Renewable Engineering Universiti Technologi Malaysia

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION Objective To estimate the fluid pressure drops and roughness specifications for copper

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw.

Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw. GAS PRESSURE REDUCING BALANCED APPLICATIONS: Regulation of inlet pressure to gas compressors and control of supply or distribution system pressures where the pressure to the regulator varies significantly

More information

HYDROSTATIC LEAK TEST PROCEDURE

HYDROSTATIC LEAK TEST PROCEDURE This information is proprietary and shall not be disclosed outside your organization, nor shall it be duplicated, used or disclosed for purposes other than as permitted under the agreement with Kinetics

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

Innovating Gas-Lift for Life of Well Artificial Lift Solution. The Unconventional Solution!

Innovating Gas-Lift for Life of Well Artificial Lift Solution. The Unconventional Solution! Innovating Gas-Lift for Life of Well Artificial Lift Solution The Unconventional Solution! Glenn Wilde Optimum Production Technologies Inc. Revive Energy Corp. Unconventional Oil & Gas Resources Unconventional

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Alkylphosphines. Storage and Handling Recommendations

Alkylphosphines. Storage and Handling Recommendations Alkylphosphines Storage and Handling Recommendations 2 The Phosphine Specialties Group has been producing phosphine and phosphine derivatives on a large scale for a number of years and the handling procedures

More information

SECTION P4 SEPARATION SYSTEMS

SECTION P4 SEPARATION SYSTEMS SEPARATION SYSTEMS The #1 Separator, MBD-0100 is a 3-phase separator which receives flow from the Incoming Pipeline, KAQ 0290. Gas from the Separator is directed to Fuel Gas Scrubber, and Gas Compressor

More information

How Do I Install My Garden Master Bucket Garden?

How Do I Install My Garden Master Bucket Garden? How Do I Install My Garden Master Bucket Garden? 1. On the arrival of your Bucket Garden open the bucket and remove the 4 screws from the outside of the bucket rim and pull the 2 buckets apart. Check the

More information

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve. Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.

More information

Peerless TECH SPEC FOR HIGH-EFFICIENCY, HIGH-CAPACITY, AND LOW-COST GAS AND LIQUID SEPARATION

Peerless TECH SPEC FOR HIGH-EFFICIENCY, HIGH-CAPACITY, AND LOW-COST GAS AND LIQUID SEPARATION Peerless TEH SPE Vane SEPRTORS See what Peerless can do for you. FOR HIGH-EFFIIENY, HIGH-PITY, ND LOW-OST GS ND LIQUID SEPRTION HORIZONTL SEPRTOR For handling high liquid rates and large slugs. VERTIL

More information