1

2 Water Supply - 1

3 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system. 2. Identify the causes of increased resistance or friction loss in water mains. 3. Identify the types of water main valves. 4. Define the terms static pressure, normal operating pressure, residual pressure, and flow pressure. 5. Identify the differences between dry-barrel and wet-barrel hydrants. 6. Describe the conditions which reduce hydrant effectiveness. 7. Describe and demonstrate connecting a supply hose to a hydrant and operating the hydrant. 8. Identify the apparatus and equipment necessary for a water shuttle and how to set up a portable water tank and assemble equipment to transfer water between portable tanks. 9. Demonstrate the assembly and connection of drafting equipment required for drafting from a static water supply. Water Supply - 1

4 NFPA STANDARDS Successful completion of the information in this section is necessary to fulfill the requirements of the following sections of NFPA : Fire Fighter I Standard * Connect a fire department pumper to a water supply as a member of a team, given supply or intake hose, hose tools, and a fire hydrant or static water source, so that connections are tight and water flow is unobstructed. (A) Requisite Knowledge. Loading and off-loading procedures for mobile water supply apparatus; fire hydrant operation; and suitable static water supply sources, procedures, and protocol for connecting to various water sources. (B) Requisite Skills. The ability to hand lay a supply hose, connect and place hard suction hose for drafting operations, deploy portable water tanks as well as the equipment necessary to transfer water between and draft from them, make hydrant-to-pumper hose connections for forward and reverse lays, connect supply hose to a hydrant, and fully open and close the hydrant. Fire Fighter II Standard 6.5.3* Prepare a preincident survey, given forms, necessary tools, and an assignment, so that all required occupancy information is recorded, items of concern are noted, and accurate sketches or diagrams are prepared. (A) Requisite Knowledge. The sources of water supply for fire protection; the fundamentals of fire suppression and detection systems; common symbols used in diagramming construction features, utilities, hazards, and fire protection systems; departmental requirements for a preincident survey and form completion; and the importance of accurate diagrams. (B) Requisite Skills. The ability to identify the components of fire suppression and detection systems; sketch the site, buildings, and special features; detect hazards and special considerations to include in the preincident sketch; and complete all related departmental forms. 2 - Water Supply

5 I. Water Supply A. Water has always been the primary extinguishing agent for fire fighting for its: 1. Availability 2. Economy 3. Effectiveness 4. Ease of storage and transfer B. Fire fighters must have a knowledge of water supply systems and how to use these systems to supply water for fire fighting efforts II. Water Distribution Systems (Essentials p. 594) A. Public and private water supply systems typically serve large areas with numerous individual properties 1. May be a city-operated utility, a public water supply district, or a private water company 2. Several municipal water systems in Missouri have been sold to private corporations B. Sources of water supply 1. Surface water a. Rivers b. Lakes c. Reservoirs Water Supply - 3

6 2. Ground water a. Water wells b. Water-producing springs C. Means of moving water 1. Direct pumping system a. Uses pumps to take water from the primary source to the treatment process and into the distribution system b. Most direct pumping systems are found in agricultural and industrial settings c. The main disadvantage is the reliance only on pumps and electricity to operate the pumps d. Backup generators and duplicate pumps may be needed for reliability 2. Gravity system a. Uses a primary water source at a higher elevation than the distribution system b. Gravity pressure is adequate only when the primary water source is more than 100 feet higher than the highest point in the water system 3. Combination systems a. Most communities use a combination direct pumping and gravity system b. Water is pumped from the treatment facilities to elevated storage tanks 4 - Water Supply

7 c. Gravity flow is supplied by elevated tanks for storage and pressure (1) When consumption is high, the tanks supply extra water and pressure (2) Elevated reservoirs can ensure the water supply when other parts of the system may be inoperable D. Processing or treatment facilities 1. Provide treatment to remove contaminants and add chlorine to kill bacteria 2. May add fluoride or oxygen 3. The fire department's concern with treatment facilities is that a maintenance problem, power loss, or fire may reduce the volume and pressure of available water supplies 4. A secondary potential problem for fire fighters is the large quantities of chlorine which can be stored at these facilities E. Distribution systems 1. The amount and pressure of water that a distribution system can deliver depends on: a. The capacity of its pipe network b. The capacity of elevation of its storage tanks 2. As water flows through piping, its movement causes friction which reduces pressure Water Supply - 5

8 a. Friction loss is also increased by encrustations inside water mains b. Friction loss reduces the volume and pressure available from fire hydrants c. Less pressure will be lost when fire hydrants are supplied from two or more directions (1) Dead-end hydrant: receives water from only one direction (2) When a hydrant receives water from two or more directions, it has a circulating feed or looped line 3. Grid system: a distributing system that has circulating feed from several mains a. Primary feeders: large pipes that convey large quantities of water for distribution to smaller mains b. Secondary feeders: intermediate-sized pipes within the loops of primary feeders that aid the concentration of flow c. Distributors: smaller mains serving hydrants and blocks of consumers d. Two or more primary feeders should run from the water source to high-risk and industrial areas 4. Recommended size of supply mains from the American Water Works Association a. Residential hydrant supply mains: 6-inches 6 - Water Supply

9 b. Business and industrial districts: 8-inches with cross-connecting mains every 600 feet c. 12-inch mains should be on principal streets and in long mains 5. Water main valves a. Valves should be within the grid system so small districts can be shut off without affecting the entire system (1) The water department must be able to open valves when increased flow is needed during an emergency (2) In the event of a main break, the valves may have to be closed to isolate areas b. Indicating valves: visually show if valve is open or closed (1) Post indicator valve: a hollow metal post housing the valve stem with a small window which shows if the valve is open or shut (2) Outside screw and yoke (OS&Y) valve (a) Has a yoke on the outside with a threaded stem (b) The stem is extended when the valve is open and invisible when the valve is closed Water Supply - 7

10 c. Non-indicating valves (1) Usually buried or in manholes (2) Usually requires a special wrench or water valve key to operate d. Gate valves (1) May be indicating or non-indicating (2) Usually the non-rising stem type (3) The control valve is operated by a handle or screw mechanism which rises or lowers a plate into or out of the waterway e. Butterfly valves (1) May be indicating or non-indicating (2) The control valve is operated by a handle mechanism which rotates a valve disk to open or shut the valve f. If valves are not fully opened, friction loss increases and available water decreases 6. Water mains a. Underground water mains may be constructed of: (1) Cast or ductile iron (2) Asbestos cement (3) Steel 8 - Water Supply

11 (4) Polyvinyl chloride plastic (PVC) (5) Concrete b. A water main must be the proper type for the soil conditions and pressures needed (1) Some soil types may corrode some materials (2) Extra protection may be needed to prevent breaks in certain soil types c. The interior surface of the pipe creates resistance (friction loss) to water flow d. Encrustations and sediments in a pipe cause increased friction loss F. Pressures within water supply system 1. Pressure is the velocity of water through pipe or hose of a certain size 2. Static pressure a. Stored potential energy available to force water through pipes or hose b. Normal pressure within a system before a hydrant is opened c. True static pressure is rarely found in a water system 3. Normal operating pressure: pressure on a water system during normal use demands Water Supply - 9

12 4. Residual pressure: pressure left in a water system at a location when water is flowing 5. Flow pressure: forward pressure at a discharge opening III. Fire Hydrants (Essentials p. 605) A. Hydrant construction 1. Barrels, bonnets, and foot pieces are constructed from cast iron 2. Internal working parts are usually made of bronze 3. Valve facings may be rubber, leather, or composite materials B. Hydrant operations 1. As a safety precaution, tighten hydrant outlet caps that will not be used 2. Turn the outlet cap nut counterclockwise and remove the outlet cap 3. If time permits, flush the hydrant before connecting hoses 4. Turn operating nut in direction of arrow (usually counterclockwise) 5. Open and close hydrant slowly and fully a. Opening too fast may cause the hose attached to flail violently or burst 10 - Water Supply

13 b. Closing too fast can cause a sudden increase in water pressure within the water system (water hammer) C. Dry-barrel hydrants 1. Used in areas where freezing occurs 2. The valve holding back the water is located underground, below the anticipated frost line for the area 3. Water in the barrel of dry-barrel hydrant drains through a small drain hole at the bottom of the hydrant after closing 4. If the hydrant is not completely opened or closed, the drain hole will be partially open and cause soil erosion around the hydrant base 5. To test the ability for a hydrant to drain: a. After flowing water, close the hydrant and cap all discharges except one b. Place a hand over the open discharge c. A slight vacuum should be felt on the hand as the barrel drains 6. If water is bubbling up out of the ground at a dryhydrant's base when the hydrant is fully open, a broken component in the hydrant barrel is allowing water to get past the drain opening D. Wet-barrel hydrants 1. Used in areas with warmer climates where freezing is unlikely Water Supply - 11

14 2. Always filled with water to a compression valve at each outlet 3. Also referred to a "frost-free" or "California" hydrants E. Hydrant color coding from NFPA 291, Recommended Practice for Testing and Marking Hydrants 1. Light blue: 1,500 gpm or more 2. Green: 1,000 to 1499 gpm 3. Orange: 500 to 999 gpm 4. Red: less than 500 gpm 5. Local color-coding of hydrants differ depending on the jurisdiction F. Hydrant locations 1. Different jurisdictions have different requirements for hydrant spacing and locations depending on: a. Types of construction b. Types of occupancies c. Building densities d. Water main size e. Required fire flow for area occupancies 2. Generally, hydrants should not be spaced more than 300 feet apart in high-value districts 12 - Water Supply

15 G. Hydrant effectiveness may be affected by different factors 1. Obstructions erected too near a hydrant, such as signs, poles, fences, may limit access 2. Discharge outlets may face the wrong direction to allow hose attachment 3. Hydrant may have been damaged by traffic or vandalism 4. Corrosion may prevent the proper operation or impede the flow of water 5. Lack of clearance between outlet caps and the ground 6. Outlet caps missing or stuck in place with paint 7. Stem nut that cannot be turned or turns freely with no result 8. Obstructions (bottles, cans, rocks) inside hydrant outlets H. Testing hydrants 1. In some jurisdictions, hydrants are tested by a water department instead of the fire department a. Where fire departments do hydrant testing, fire fighters usually assist with the testing b. If the water system is privately-owned, the fire department should coordinate hydrant testing with the system owner Water Supply - 13

16 2. Pitot tube and gauge are used to test the flow pressure of a hydrant 3. Use of the pitot tube and gauge a. Pitot tube is held so that blade slices into water stream b. Open the petcock to make sure the air chamber is drained, close petcock c. Edge blade in stream with opening centered in stream d. Hold blade at a distance equal to about half the diameter of the orifice e. Tube should be parallel to the opening with the air chamber slightly above the center of the stream f. If the gauge is fluctuating, take the value between the highest and lowest readings 4. Fixed-mount pitot tubes are available to reduce the possibility of human error IV. Alternative Water Supplies (Essentials p. 610) A. Alternative water supplies may have to be used even in areas with adequate water systems 1. The water system may fail due to broken mains or power outages 2. Fires may occur in areas some distance from hydrants, such as fields or along limited-access highways 14 - Water Supply

17 3. Departments may have to draw water from sources such as lakes, ponds, rivers, swimming pools, and water tenders B. Drafting from a static source 1. Drawing water from a static source to supply a pumper is known as "drafting" 2. Hard suction intake hose is used primarily to draft water because it is designed to withstand the partial vacuum created when drafting without collapsing 3. Drafting operations are affected by debris, sediment, and rocks which can clog strainers, damage pumps, and clog nozzles a. Hard suction hoses must have strainers in place when drafting from a natural source b. Strainers can be supported by a ladder or floating strainer used to prevent hose from drawing in sediment c. A strainer should have at least 24-inches of water above and below it d. Floating strainers can draft from water as shallow as 24-inches deep 4. In some areas dry hydrants are installed at static water sources to supply water for fire fighting a. Usually constructed of steel or PVC pipe with strainers at the water source and large connections to connect to a pumper Water Supply - 15

18 b. In order to establish a water supply from a dry hydrant, hard suction must be used and a drafting operations set up 5. Drafting operations a. Suitable water source must be located for adequate water supply and to allow positioning of pumper nearby b. Pumper is positioned near water source c. Check hard suction coupling for dirt, debris, and worn gaskets d. The hard suction hose is attached to intake on pumper e. Strainer or floating strainer is attached to hard suction f. All connections must be air tight to allow for adequate draft g. If a floating strainer is not used, a ladder should be positioned in the water for the strainer to rest on h. Strainer is placed in water i. Pumper pulls a draft by priming the pump until positive pressure is indicated j. If unable to achieve draft, tighten connections with rubber mallet k. If still unable to get draft, lift may be too great for pumper to overcome 16 - Water Supply

19 C. Rural operations usually consist of water shuttle operations 1. Water is hauled from a supply by water tenders (tankers) to portable tanks where it can be drawn to the attack pumper 2. Water shuttles are recommended for distances greater than one-half mile or greater than the amount of supply line carried 3. Enough water tenders must be available to maintain the needed fire flow 4. To be successful, fast-fill and fast-dump times are required a. Water supply officers should be at both the fill site and dump site b. Personnel should be assigned to traffic control, fill site connections, and dumping c. If possible, tanker drivers should stay in their vehicles during the operations 5. Water shuttle operation components a. Water source - fill site b. Transport system: tankers/tenders c. Dump site - pumper drafting from tanks to either supply attack lines or supply another pumper used for fire attack d. Portable tanks (1) Range from 1,000 gallons and up Water Supply - 17

20 (2) May be collapsible or folding with a metal frame holding a synthetic or canvas duck liner (3) May be a self-supporting synthetic tank with a floating collar that rises as the tank is filled (4) Before opening a portable tank, a heavy tarp should be spread on the ground to protect the tank liner from damage (5) If possible, portable tanks should be positioned: (a) As level as possible to allow for maximum capacity (b) To allow for easy access for tankers from multiple directions (c) So as not to obstruct scene access for other apparatus (d) With the drain towards the lower side (6) Low-level strainers may be used to get the most water from the portable tanks (7) If multiple tanks are used, a jet-siphon can be used to transfer water between tanks (a) The jet-siphon may be incorporated into a low-level strainer and attached to hard suction hose, which is placed between the tanks (b) The jet-siphon draws the water through the hard suction hose 18 - Water Supply

21 e. Water tenders/tankers (1) NFPA 1901, Standard for Automotive Fire Apparatus, requires that water tenders on ground level be capable of dumping or filling rates of at least 1,000 gpm (2) Pumping water from a tanker should only by done by trained and qualified apparatus operators (3) Water tender unloading methods: (a) Gravity dumping through large (10- to 12-inch) dump valves (b) Jet dumps that increase the flow rate (c) Apparatus-mounted pumps that off-load the water (d) Combinations of these methods (4) Water tankers must be capable of being quickly refilled during emergency operations by using: (a) The best fill site or hydrant available (b) Large hoselines (c) Multiple hoselines (d) If necessary, a pumper with adequate flow Water Supply - 19

22 D. Relay pumping operations 1. Multiple pumpers can be used in a series to relay water to the scene if the water source is close enough 2. The water supply must be capable of maintaining the required volume for the incident's duration 3. The number of pumpers needed will depend on: a. The volume of water needed b. The distance from the water source to the scene c. The amount of hose available d. Pumper capacities 4. The pumper with the largest pumping capacity should be located at the water source 5. A relay pumping operation must be established quickly to be worthwhile V. Water Supply Summary A. For as long as there have been fire fighters, water has been the primary tool used to control fires B. Fire fighters must understand how water systems function to provide them with the water needed in an emergency C. More importantly, fire personnel must be proficient at getting the water from the supply source to the fire apparatus and then on the fire 20 - Water Supply

23 WATER SUPPLY QUIZ Name: Date: 1. The large pipes that convey large quantities of water for distribution to smaller mains are called. a. distributors b. secondary feeders c. primary feeders d. branch feeders 2. The pressure that is normally within a water supply system before water is flowing from the system is the. a. static pressure b. normal operating pressure c. residual pressure d. flow pressure 3. The pressure left in a water supply system when water is flowing is the. a. static pressure b. normal operating pressure c. residual pressure d. flow pressure 4. A hydrant is used in areas subject to freezing a. class A b. class B c. wet-barrel d. dry-barrel 5. Which of the following will not have an effect on hydrant effectiveness? a. Obstructions too near hydrant b. Whether it is a wet or dry hydrant c. Corrosion d. Failure to open fully Water Supply - 21

24 WATER SUPPLY QUIZ 6. Which of the following is not considered to be a part of a drafting operation? a. Static water source b. A pumper capable of drafting c. Fire hose d. Hard suction hose 7. The forward pressure at a discharge opening in a water supply system is the. a. static pressure b. normal operating pressure c. residual pressure d. flow pressure 8. Water bubbling up out of the ground at a dry hydrant's base when the hydrant is fully open is an indication that. a. the hydrant is properly draining b. excessive pressure within the hydrant is being relieved c. a broken component in the hydrant barrel is allowing water to get past the drain opening d. the drain opening at the base of the hydrant has ruptured 9. Drawing water from a static source to supply a pumper is known as. a. drafting b. a water shuttle c. gravity dumping d. jet-siphoning 10. When a hydrant connection is made, the hydrant should be opened. a. until water begins to flow b. to ½ of its maximum c. to ¾ of its maximum d. to a fully open position 22 - Water Supply

25 VENTILATION INSTRUCTOR'S GUIDE PRACTICAL SKILLS These Lead Instructor Practical Skills are designed to provide the Lead Instructor for a Fire Fighter I and II course with a more detailed overview of the practical skills required of all students. The appropriate skills from NFPA are listed at the front of each skill's section. Although the skills from NFPA are written as Job Performance Requirements, these have been divided into individual skill elements. This is to allow for consistency in the evaluation of each skill element. Students must successfully complete each step of each practical skill during the practical skills evaluation portion of a Fire Fighter I and II course. At the time of a Fire Fighter I and II Certification Examination, the skill steps have been prioritized to allow a student to miss a predetermined number of steps Water Supply

26 MISSOURI DIVISION OF FIRE SAFETY FIRE FIGHTER I & II PRACTICAL SKILLS Water Supply Successful completion of the practical skills in this section are necessary to fulfill the requirements of the following sections of NFPA : Fire Fighter I Standard * Connect a fire department pumper to a water supply as a member of a team, given supply or intake hose, hose tools, and a fire hydrant or static water source, so that connections are tight and water flow is unobstructed. Water Supply - 25

27 MISSOURI DIVISION OF FIRE SAFETY FIRE FIGHTER I & II PRACTICAL SKILLS Water Supply - NFPA , Demonstrate Operating a Hydrant Skill Objective: The candidate, given an equipped fire apparatus and hydrant, wearing protective equipment (SCBA optional), shall demonstrate making a hydrant connection from the hydrant to the pump intake using a 2 1 / 2 " soft supply hose and then fully open and close the hydrant. Skill Procedure: The evaluator should arrange for a fire apparatus to be positioned near a fire hydrant and identify which supply hose the candidate shall use to achieve the objective. The candidate shall then make the hydrant connection and fully turn the hydrant on. Students are allowed two chances at each skill for successful completion. Any step listed in italics missed shall result in failure of the skill. Otherwise, students are allowed to miss a maximum of two of the following steps and pass this skill. Items to be checked If the candidate: 1. As a safety precaution, tightens hydrant outlet caps that will not be used 2. Loosens appropriate hydrant cap and places the wrench on the operating nut 3. Connects hose completely to the hydrant 4. Threads other hose coupling to pump intake 5. Removes all kinks from the hose 6. Fully opens the hydrant 7. Closes hydrant fully and returns equipment 8. Checks for hydrant draining 26 - Water Supply

28 MISSOURI DIVISION OF FIRE SAFETY FIRE FIGHTER I & II PRACTICAL SKILLS Water Supply - NFPA , Demonstrate Assembling the Equipment for Drafting Skill Objective: Given the necessary equipment, the fire fighter shall assemble and connect the equipment necessary for drafting from a static water supply source. Skill Procedure: The candidate should be given all of the necessary equipment to perform this task. This skill should be conducted in an open area free of traffic and pedestrians. It is not necessary to actually draft water as part of the skill. If possible, the candidate should use the pump intake the same size as the hard sleeve to reduce the need for adapters. Students are allowed two chances at each skill for successful completion. Students are allowed to miss a maximum of one of the following steps and pass this skill. Items to be checked If the candidate: 1. Checks gaskets on hard suction hose for dirt or gravel 2. Connects the sections of hard suction hose 3. Connects the strainer to one end of the hard suction hose 4. Removes pump intake cap on pumper 5. Connects hard suction hose to pumper intake 6. Hand tightens hard suction coupling to pump intake 7. Dismantles drafting equipment and returns to proper storage on apparatus Water Supply - 27

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 14 Water Supply Learning Objectives Explain the ways water supply system components are used by firefighters. Describe types

More information

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST

More information

Apparatus Operator Refresher Training Program

Apparatus Operator Refresher Training Program Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct

More information

Essentials of Fire Fighting 6 th Edition Firefighter I

Essentials of Fire Fighting 6 th Edition Firefighter I 1 Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 14 Water Supply Learning Objective 1 2 Explain the ways water supply system components are used by firefighters. 14 2 There are two types

More information

Chapter 14 Water Shuttle Operations

Chapter 14 Water Shuttle Operations 1. Which of the following statements about water shuttle operations is TRUE? A. Water shuttle operations may create a dramatic hose failure B. Water shuttle operations are safer than relay pumping operations

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 W A T E R S U P P L Y O P E R A T I O N S R U R A L ( 2. 1 ) Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 Revised by Lt. Greg Van Heel, Eng. Chris Wining, and FF. Uriel

More information

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE HYDRANT/WATER POINT INSPECTION AND MAINTENANCE SCOPE This guideline shall apply to all members of the Stoney Point Fire Department (SPFD) and shall be adhered to by all members. Stoney Point Fire Department

More information

TurboDraft. Fire Eductor Operating Instructions.

TurboDraft. Fire Eductor Operating Instructions. TurboDraft Fire Eductor Operating Instructions 1234djfkjldfjlkdjfklsdjlkjfdslkjfsd Table of Contents Description Page Introduction........ 1 Safety Guidelines... 2 Care and Maintenance... 3 TurboDraft

More information

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 W ATER S UPPLY O PERATIONS R URAL (1.1) Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 NFPA 1142 Standard on Water Supplies for Suburban and Rural

More information

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines. Dry Hydrants What is a Dry Hydrant? A dry hydrant is a non-pressurized pipe system permanently installed in existing lakes, ponds and streams that provides a suction supply of water to a fire department

More information

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1 Skill Sheet: 1 Standard 4.2.1, 4.2.2 Task: Perform and document routine test, inspection and servicing functions on specified systems and components. Performance Outcome: Given a fire department pumping

More information

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question. Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 5 TOPIC: SUPPLY LINES AND SALVAGE LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED

More information

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA PROPERTY INSURANCE ASSOCIATION OF LOUISIANA WATER HAULING GUIDELINES NOTE: Effective immediately, Fire Departments in Louisiana who receive credit for water hauling will receive their credit through a

More information

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure

More information

Model 420-HY Pressure Regulating Hydrant Valve

Model 420-HY Pressure Regulating Hydrant Valve Model 420-HY Pressure Regulating Hydrant Valve INSTALLATION OPERATION MAINTENANCE 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment is the most important

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question. Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised DRIVER OPERATOR Page 1 of 14 HYDRAULICS Hydraulics applied in the dynamic fire ground environment is an art that comes with study and experience. The following describes the factors that must be mastered

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College August, 2018 revised

More information

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel

More information

Chemical Injection Technologies Installation/Service Bulletin

Chemical Injection Technologies Installation/Service Bulletin Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

Apparatus Operator/Pumper

Apparatus Operator/Pumper Skill Number: AOP-1 Operate Fixed Systems Objective: 4.3.7 (A) (B) 1. The candidate shall be provided with the equipment to complete this objective including apparatus. 2. The candidate uses safety precautions.

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc. Design Manual Chapter 4 - Water Mains 4C - Facility Design 4C-1 Facility Design A. General Water mains and appurtenances, including hydrants and valves, should be provided along all streets including connections

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

FIRE FIGHTER II JPR: FFII-1A

FIRE FIGHTER II JPR: FFII-1A JPR: FFII-1A STANDARD: 6.1.2 Task: Implement Incident Management System. General Requirements The candidate shall demonstrate the ability to determine need for command, organize and coordinate an incident

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2-12 BERMAD. Application Engineering Bermad Pressure Reducing Valve Model: 720-UL INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

Driver Operator Pumps: Basic Pump Operations

Driver Operator Pumps: Basic Pump Operations Driver Operator Pumps: Basic Pump Operations 5 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Basic Pump Operations Skills Book NFPA

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

III. Identify the initial installation requirements for standpipe systems

III. Identify the initial installation requirements for standpipe systems Design Basic Design Requirements 1. Must provide 500 GPM at 65 PSI to the highest most remote standpipe riser outlet. 2. 250 GPM for each additional standpipe total not to exceed 2500 GPM III. Identify

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Fire Apparatus Operator Aircraft Rescue and Fire Fighting Fire Apparatus Operator Aircraft Rescue and Fire Fighting Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2014 Edition. Alabama Fire College

More information

WW-730. Pressure Sustaining/Relief Control Valve

WW-730. Pressure Sustaining/Relief Control Valve WW-730 Pressure Sustaining/Relief Control Valve Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 730 Pressure Relief / Sustaining Valve is an automatic control valve designed to

More information

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2 Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,

More information

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Model GPR Primary Pressure Regulating Valve. Instruction Manual Model GPR-2000 Primary Pressure Regulating Valve Instruction Manual Please read this instruction manual thoroughly before using the primary pressure regulating valve, so that you may do so correctly and

More information

Cozumel Turbodraft. Operational Considerations

Cozumel Turbodraft. Operational Considerations Cozumel Turbodraft Operational Considerations Safety Guidelines Safety Guidelines 1. Carefully read and follow all operating instructions before putting the TurboDraft unit into service. 2. Be sure all

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 revised

More information

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Model CYCLE GARD II, CI & CNA YOUR PRODUCT INFORMATION: Model Number: Date: Serial Number:

More information

Fire Apparatus Operator: ARFF

Fire Apparatus Operator: ARFF Fire Apparatus Operator: ARFF Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College November 26, 2018 Alabama

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

DS05C,D,G Dial Set Pressure Regulating Valves

DS05C,D,G Dial Set Pressure Regulating Valves DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU FIRE FIGHTER II SKILL STATION MENU STATION TASK(S) A FIREGROUND OPERATIONS/FIRE COMMUNICATIONS MANDATORY B SPRINKLER DRAIN/PRESSURES RANDOM C PITOT GAUGE USE RANDOM D INSPECTION/MAINTENANCE: GENERATOR,

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Installation of Your SprayMaster System

Installation of Your SprayMaster System Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each

More information

D05 Pressure Regulating Valves

D05 Pressure Regulating Valves D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction

More information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3 Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Lecture 10 : Sewer Appurtenances

Lecture 10 : Sewer Appurtenances 1 P age Module 8 : Sewer Appurtenances Lecture 10 : Sewer Appurtenances 2 P age The structures, which are constructed at suitable intervals along the sewerage system to help its efficient operation and

More information

MEGR-1912 Instruction Manual

MEGR-1912 Instruction Manual MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX

More information

D05T Compact Design Pressure Regulating Valves

D05T Compact Design Pressure Regulating Valves D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.

More information

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION Monroe Fire Department Standard Operating Guidelines Drivers Clearance & Training Program Guidance ADMINISTRATION Goal: to develop and maintain a force of driver-operators and ensure they are proficient

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

Irrigation System Winterization and Pressurization Procedures

Irrigation System Winterization and Pressurization Procedures Irrigation System Winterization and Pressurization Procedures Introduction Any time that an irrigation system is filled and pressurized, or when the system is drained and water flushed from the system,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING In SANS 10105 you will find the Minimum water pressure for both the hydrant and the hose reel. Which is 300KPA Manufacturing Standard SANS 543 1 Front & Back plates 2 Curved Plate 3 Waterway assembly 4

More information

Idaho Fire Service Technology Fire Fighter II

Idaho Fire Service Technology Fire Fighter II ICS Skill Requirements Skill Sheet: 1 STANDARD: 6.1.2 TASK: Organize, coordinate, and function within an incident management system. PERFORMANCE OUTCOME: The candidate shall be able to determine the need

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

22. Specialty Valves.

22. Specialty Valves. 22. Specialty Valves. a. Types of Specialty Valves. 1) Use of the following specialty valves is covered in this section: Altitude Valve, Pressure Reducing Valve, Pressure Relief Valve, Swing Check Valve,

More information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,

More information

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET Fire Fighter II Skill Stations: NFPA 1001 2013 Edition Station A Fire Ground Communications & Operations / Interior Attack Coordination MANDATORY STATION Station B Sprinkler Drain/Pressures RANDOM STATION

More information

Bermad Model:

Bermad Model: Bermad Model: 405-02 Manually Operated Hydraulic Valve INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around

More information

Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream.

Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream. UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream. 2. Identify the advantages and disadvantages

More information

Jet Swim Installation instruction

Jet Swim Installation instruction Jet Swim 2000 Jet Swim 2000 Liner pool 1. Remove the stainless steel front plate and cut out the pool wall according to the hole pattern. The center of the Jet Swim housing must be a minimum of 170 mm

More information

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL I-867-4T 867-4T Pressure Reducing Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR FUTURE REFERENCE WARNING Read and understand all instructions

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

Chapter 1 FF I Orientation and Fire Service History

Chapter 1 FF I Orientation and Fire Service History Chapter 1 FF I Orientation and Fire Service History After completing this lesson, the student shall be able to describe how the history and culture of the fire service influence its basic mission, the

More information

DW Module 8: Distribution Answer Key

DW Module 8: Distribution Answer Key DW Module 8: Distribution Answer Key Unit 1: Unit 1 Exercise 1. To become certified in distribution systems, a person must: a. Successfully complete the Water Class E Distribution System certification

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION, OPERATION & MAINTENANCE MANUAL AWWA C500 SOLID WEDGE GATE VALVE 2 72 NRS and OS&Y Series 100 and Series 105 TABLE OF CONTENTS SECTION PAGE # Equipment List 2 General 3 Receipt and Inspection

More information

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B INSTRUCTION MANUAL MM-110B Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls APPLICATIONS: Use with other pneumatic devices, for liquid level sensing in

More information

1 Exam Prep. Tabs and Highlights

1 Exam Prep. Tabs and Highlights 1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,

More information

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd Page 1 of 10 Hodge Clemco Ltd SG-300 Suction Gun Date of issue: 24/08/92 TS.OM64A Owner s Manual Hodge Clemco Ltd Orgreave Drive Sheffield S13 9NR Tel: 0114 254 8811 Email sales@hodgeclemco.co.uk www.hodgeclemco.co.uk

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs () JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including all subsections)

More information

Varying pump capacity affects the required hoseline diameter

Varying pump capacity affects the required hoseline diameter Slide 1 Rural Fire Command by Larry Davis Issue #34 October 2005 H 2 O On The Go Varying pump capacity affects the required hoseline diameter 1 Slide 2 Training America s Rural Fire & Emergency Responders

More information

ELKHART BRASS MANUFACTURING COMPANY

ELKHART BRASS MANUFACTURING COMPANY ELKHART BRASS MANUFACTURING COMPANY INSTALLATION and OPERATING INSTRUCTIONS for MODEL UP PRESSURE RESTRICTING HOSE VALVES I. Models and Sizes Covered: UP-20, 1-1/2" size UP-25, 1-1/2" size UP-20, 2-1/2"

More information

Chapter 10 SWIMMING POOLS

Chapter 10 SWIMMING POOLS 4-10-1: COMPLIANCE REQUIRED: Chapter 10 SWIMMING POOLS It shall be unlawful to construct, maintain, install or enlarge any swimming pool in the City except in compliance with the provisions of this Chapter.

More information

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE

KECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE APPLICATION/SERVICE: The NO. 7 internally piloted valves are recommended where tight closing is essential. The NO. 7 is most

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) 100 PPD (2 kg/h) Maximum 250 PPD (5 kg/h) Maximum 500 PPD (10 kg/h) Maximum - 1-122.6006.9 These instructions describe the

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information