Pressure Control (and Check) Valve
|
|
- Octavia Golden
- 6 years ago
- Views:
Transcription
1 Pressure ontrol (and heck) Valve PRSSUR OTRO (A ) VAV 50 to 80l/min 4Pa eatures qthis circuit control valve works as a sequence valve, unloading valve, and counter balance valve. waximum operating pressure is Pa {4kgf/cm }. ethough a direct type valve, there is little pressure override. rthe mounting surface of the gasket conforms to the ISO standards shown in the table below. Specifications odel o. Screw ounting asket ounting () Q-T0-*A- () Q-T0-*A- () Q-T0-*A- () Q-0-*A- () Q-0-*A- () Q-0-*A- ominal iameter (Size) /8 aximum Working Pressure aximum low Rate l/min {4} /4,, 0 Ports 50 ¼ 80 Pressure adjustment range Type A 0.5 to 5 {. to 8.7} Type 0.5 to.75 {5. to 7.9} Type 5 to.5 {8.7 to 5.7} Type.75 to 7 {7.9 to 7.4} Type.5 to 4 {5.7 to 4} Weight kg T Type Type.9 (.) 5.0 (5.4).5 (.8).0 (.5) asket Surface imensions ISO ISO ISO (.) (.8) Weight values in parentheses are for when a check valve is included. The cracking pressure of the check valve is 0.Pa {.0kgf/cm }. xample circuit When using type. xplanation of model o. ()Q 0 xample circuit When using type. esign number Pressure adjustment range A,,,, (ote: Type pressure adjustment is note available for Type.) Type,,, 4 ominal diameter (size) ounting method T: Screw ounting : asket ounting Pressure control valve Pressure control and check valve andling z To adjust pressure, loosen the lock nut and then rotate the adjusting bolt clockwise (rightward) to increase pressure or counterclockwise (leftward) to decrease it. x The pressure adjustment range is expressed in terms of cracking pressure. c Run the out port of Q-T/** type and 4 directly to the tank. v The following describes the method for using Types and. Application of back pressure to the valve output side such as in the example circuit shown below, use Type or Type and run the drain port directly to the tank. b When two or more of these valves are ganged in sequence, make sure the setting pressure (cracking pressure) differential between them is at least Pa {0.kgf/cm }. n Vibration (chattering) may occur with the () Q-***-- depending on operating conditions when using type and pressure adjustment range. Use external drain type if it happens. m Type is standard. When Type,, or 4 is required, make modifications in accordance with the figures on the next page. odifications change the valve type, so be sure to change the markings on the nameplate., Use the following table for specification when a sub plate is required. odel o /8-0X-0 / -0-0 /4-0X X-0 odel o. Pipe Weight iameter kg ¼ ½ olt imensions Q'ty () Q-0-** () Q-0-** () Q-0-** Applicable Pump odel. () Q-0-**-.9 () Q-0-**-.7 () Q-0-**- ote) These sub plates can also be used for reducing valves.. The following are the bundled mounting bolts. Tightening Torque m{kgf cm} 45 to 55 {40 to 50} ote) or mounting bolts, use bolts of.9 strength classification or equivalent. Pressure ontrol Valve -5
2 A Q-***-**- IS Symbol Type Type Type Q-***-**- Type Type Type R R Type is standard. Installation imension rawings Type R Q-T**-*-(Screw ounting) R Pressure ontrol Valve I Type Type R AX.A ameplate xternal drain port odel o. A P Q () Q-T0-** /8 () Q-T0-** /4 () Q-T0-** ¼ Q-**-*- (asket ounting) exagon nut - Rc Q -P Attachment port φ Type exagon nut xternal drain port - φ 7.5x counterbore φ holes ameplate O AX.A Attachment port odel o. A Q-0-** Q-0-** Q-0-**
3 Installation imension rawings Type Q-T**-*- (Screw ounting) Type xternal drain port exagon nut R AX.A - Rc Q Type ameplate odel o. A P Q Q-T0-** /8 Q-T0-** /4 Q-T0-** ¼ Q-**-*- (asket ounting) -P Attachment port Pressure ontrol Valve Type exagon nut AX.A xternal drain port - φ 7.5x counterbore φ holes ameplate φ Attachment port odel o. A Q-0-** Q-0-** Q-0-**
4 A Pressure ontrol Valve I Sub Plate -***-0 odel o. AA QQ RR SS TT UU VV WW XX YY -0-0 / X-0 / -0-0 / X ¼ X-0 ½ Performance urves haracteristics () Q-T0-**-. low path {.}.4 low path {4.}. {.}.0 {0.} { 8.} {.} { 4.} 0. {.0} UU- 0 tap xternal drain TT SS RR XX WW - φ VV AA φ 7 depth 8 ydraulic Operating luid inematic Viscosity mm /s () Q-T0-**- ote) The figure shows size 0(X), with four 0 tap holes for size 0(X) and 0(X) valve mounting bolts. ote) When a valve cover external drain and external pilot port are used, remove the plugs from the sub plate external drain and external pilot port. () Q-T0-**- () Q-0-**- () Q-0-**- () Q-0-**- QQ - φ 4 hole 4- φ φ 7.5 x counterbore xternal pilot - Rc YY - Pa{kgf/cm} low path (pressure adjustment A, type). {.} low path (pressure adjustment,, type).4 {4.} low path. {.}.0 {0.} { 8.} {.} { 4.} 0. {.0} low path (pressure adjustment A, type). {.} low path (pressure adjustment,, type).4 {4.} low path. {.}.0 {0.} { 8.} {.} { 4.} 0. {.0} O low path. low path {.} {4.} {.} {0.} { 8.} {.} { 4.} {.0} low path (pressure adjustment A, type). low path (pressure adjustment,, type).4 low path {.} {4.} {.} {0.} { 8.} {.} { 4.} {.0} low path (pressure adjustment A, type). low path (pressure adjustment,, type).4 low path {.} {4.} {.} {0.} { 8.} {.} { 4.} {.0}
5 Pressure low Rate haracteristics : Press rise : Pressure drop () Q-*0-A- () Q-*0-- () Q-*0-- Pressure. {.}. {.}.0 {0.} 0.9 { 9.} Pressure Pa {kgf/cm }. {.4}. {.4}.0 {}.9 {9.4}.8 {8.4} Pressure Pa {kgf/cm } 5.0 {5.0} 4.5 {45.9} 4.0 {4}.5 {5.7} { 8.}.7 {7.}.0 {} () Q-*0-- () Q-*0-- Pressure 0 {0} 9 {9.8} 8 {8.} 7 {7.4} {.} () Q-*0-A- Pressure 7 {7} {} 5 {5} 4 {4} {} {} () Q-*0-- () Q-*0-- Pressure ontrol Valve Pressure. {.}. {.}.0 {0.} 0.9 { 9.} Pressure. {.4}.0 {}.9 {9.4}.8 {8.4} Pressure 5.0 {5.0} 4.5 {45.9} 4.0 {4}.5 {5.7} { 8.}.7 {7.}.0 {}
6 A Pressure low Rate haracteristics () Q-*0-- : Press rise : Pressure drop () Q-*0-- Pressure 0 {0} 9 {9.8} 8 {8.} 7 {7.4} Pressure Pa{kgf/cm } 8 {84} 7 {7} 5 {} {5} 4 {4} {.} {} () Q-*0-A- () Q-*0-- () Q-*0-- Pressure ontrol Valve I Pressure. {.}. {.}.0 {0.} 0.9 { 9.} { 8.} () Q-*0-- Pressure Pa {kgf/cm }. {.4}.0 {}.9 {9.4}.8 {8.4}.7 {7.} () Q-*0-- Pressure 5.5 {5.} 5.0 {5.0} 4.5 {45.9} 4.0 {4}.5 {5.7}.0 {} {84} Pressure 0 {0} 9 {9.8} 8 {8.} 7 {7.4} Pressure 7 {7} {} 5 {5} 4 {4} {.} {} O -0
7 ross-sectional rawing Q-**-**- Part o ote) The illustration shows the configuration for pressure adjustment ranges Type, Type, and Type. or Type A and Type, part number plunger is eliminated, and the part number 4 piston, part number 5 spring are different. Seal Part ist (it odel umber RQS-***()) Part ame Type/Part umber Part o. Part ame ody over over 4 Piston 5 Spring Plunger 7 Push rod 8 Screw 9 ut 0 Spacer ameplate Poppet Spring guide 4 Spring 5 Pin Plug 7 Plug 8 Screw 9 O-ring 0 O-ring O-ring O-ring O-ring 4 O-ring ote) Part numbers,, 4, and 4 are not required when there is no check valve. Q-0-**- Q-T0-**- Q-0-**- Q-T0-**- Q-0-**- Q-T0-**- 9 O-ring R-90 P R-90 P R-90 0 R-90 0 R-90 P40 R O-ring R-90 P R-90 P R-90 P R-90 P R-90 P R-90 P 4 O-ring R-90 P R-90 P R-90 P R-90 P R-90 PA R-90 PA O-ring R-90 P0 R-90 P R-90 5 O-ring R-90 P R-90 P R-90 P 4 O-ring R-90 P R-90 P R-90 P4 R-90 P4 R-90 P R-90 P ote) The materials and hardness of the O-ring conforms with IS 40. or the *** part of the kit number, specify the valve size (0, T0). To specify inclusion of a check valve, add to the end. Q'ty Pressure ontrol Valve -
20 to 280l/min 21MPa. econnecting a remote control valve to the vent port allows remote control of adjustment pressure.
Pressure Reducing (and heck) Valve eatures PRSSUR RU ( ) VV to 8l/min Pa -***-*- R -***-*- Specifications qthis valve is used when part of the circuit uses pressure that is lower than the main circuit.
More informationElectro-hydraulic Proportional Flow and Direction Control Valve
lectro-hydraulic control valve his valve uses a D solenoid in a traditional 4- way solenoid valve to create a solenoid valve capable of both direction switching and highspeed control. he lineup consists
More informationE SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description
4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationDigital relief valves D-CG
Digital relief valves D-G unctional Symbols D-G- Specifications Size Maximum working pressure Rated flow Maximum flow Maximum adjustable pressure Ma Minimum control pressure Hysteresis Repeatability emperature
More informationRP series Rotor Pumps
ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting
More informationDigital directional & flow control valves D-DF(R)G
Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports
More informationPRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting
REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set
More informationIndex Table. Model 794. Installation, Operating and Maintenance Instructions
CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009
More informationIN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)
IN-LIN HK VLVS IT- / 3 / / (/,3/8,3/,-/) RIGHT NGL HK VLVS RT / RG-3 / / (3/8,3/,-/) Up to 5 MPa (33 PSI), 3 L/min (33 U.S.GPM) Pub. - IRTIONL ONTROLS These valves allow free flow in one direction and
More informationSmooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More informationFilter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.
eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator
More informationMin. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.
Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They
More informationSmooth Vent Valve XVD. Series
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More informationSmooth Vent Valve. XVD Series
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationDirectional Controls
Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP
More informationRegulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)
eries R 2- ow to Order opper, fluorine and silicon-free + Low particle generation il hread type Rc 0 R 03 2 R 03 ody size / ith bracket Round pressure ith set nut tandard specifications odel luid roof
More informationAxial piston pumps type PVC
www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise
More informationAxial piston pumps type PVC
www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low
More information005 Series Modular Valves
5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationP2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES
52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by
More informationMECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting
MCHNICLLY ORD VLVS Rotary ype : DR/DRG- Cam Operated : DC/DCG-, hreaded Connection/ Mounting General Information Up to 5 Ma (6 SI), L/min (6. U.S.GM) ub. C-6 hese valves are chiefly used to shift the pilot
More informationVickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94
Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More informationManapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM
Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich
More informationPilot Operated Check Valves
Pilot Operated Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking
More informationDirectional Controls
Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationlternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0
ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant
More informationPilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size
More informationWK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION
2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems
More informationFlow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)
Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationIntroduction. Part one: Identify the Hydraulic Trainer Components
The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify
More informationDirectional Valves. Hydraulic Operated Directional Valves
Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726
More informationVK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010
VK/VP SERIES : Sealless Vertical Pump Assembling Instructions 2010 20610 Manhattan Place Suite 116 Torrance, CA 90501 Phone: 310-328-9114 Fax: 310-328-9441 1. Motor Shaft and Pump Base (1) (2) Place a
More informationHydraulic Punch Drivers
SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationSPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:
Catalog HY14-255/US Technical Information General Description sandwich type pressure s are typically used in combination with proportional directional control valves. The keeps the pressure drop over the
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationLogic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)
Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min
More informationSandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More informationDocument How to Set Single Stage Press Pressures
Published Document Number: IIFUUC01 Specified Date: 20040701 As-of Date: 20040701 Access Date: 20040701 Depth: detail Applicability: not used Language Code: ENG01, Purpose: publication, Format: 1colA Document
More informationMODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.
F MODULES YUKEN's Modular Valves are stack type valves, and require no piping. hey not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking
More informationSystemStak Valves. ISO4401 Size 02
SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and
More informationPneumatic Function Fittings Metric & Inch
Metric & nch Sensor Fitting Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage Simpler pneumatic systems liminates need for electrical reed switches
More informationISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4
Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose
More informationHydraulic Piston Accumulators
Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed
More informationPressure regulators Manually operated Fine setting valves. Brochure
Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex
More informationALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data
ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet
More informationCheck valve hydraulically pilot operated
Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents
More information3-Way Pressure-Reducing Cartridge, Size 2 4
-Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher
More informationPressure reducing valve, direct operated, type DR 5 DP Huade América 1
Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to
More informationRE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.
Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationOperating Instructions Models 36200, , 46200, Hydrostatic Test Pumps
Operating Instructions Models 36200, 362000, 46200, 462000 Hydrostatic Test Pumps 46200 DIMENSIONS: 28 (70cm) L x 24 (60cm) W x 38 (87.5cm) H WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INTAKE
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationVICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B
VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationFilter Regulator 21 AW 30 K F 03 BG JN. Description. Without backflow function. Rc NPT 1/8 1/4 3/8 1/2 3/4
eries eries ilter Regulator ilter Regulator with ackflow unction ow to Order lean series opper, fluorine and silicon-free low particle generation ilter regulator 10 03 21 03 q w e r t y "" must always
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationB2KL: 6-way ball valve with male thread, PN 16
Product data sheet 3.1 58.001 K: 6-way ball valve with male thread, PN 16 How energy efficiency is improved fficiency means precise control and low actuating forces eatures 6-way ball valve for changeover
More informationIndustrial Regulator Series 1800/2000
E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86 merican Meter Series
More information42 Series. Pneumatic. Lever / Pedal Valves 4-Way, 5-Port, 2 & 3-Position. Section Q. Pneumatic
42 eries Lever / edal Valves 4-Way, -ort, 2 & -osition ection asic Valve unctions...2 42 eries asic Valve eatures... ommon art Numbers...4 odel Number Index... tacking anifold ystems...6 imensions Lever
More informationThin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.
Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W
More informationWhisper Pump Service and Repair Guide
VPV Vane Pump Whisper Pump Service and Repair Guide Hydraulics Welcome to the Service Guide for the VPV Pump! Dear Customer: First of all we would like to thank you for choosing the Bosch VPV Pump. This
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note
More informationPressure-Relief Cartridge Valve, Size 4
Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure
More informationInstallation and operating manual. Pneumatic control station LK product no: PCS 1-10
LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationThe Enerpac Lightweight Aluminum Cylinders
The nerpac Lightweight luminum s Shown: RC, RCL, RC, and RR R : 20-150 tons - inches Lightweight, easy to carry and position to allow a higher cylinder capacity-to-weight-ratio Non-corrosive by design,
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationLINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter
LINDGREN-PIAN, INC. LS-3 / LS-4 Line Setter MOUNTING The Lindgren-Pitman Line Setter should be mounted on or near the transom of the boat such that the line will fall overboard as it leaves the exit. The
More informationHPB25 Hydraulic Paving Breaker
INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com
More informationALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.
Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More information(Refer Slide Time: 0:26)
Fundamentals of Industrial Oil Hydraulics and Pneumatics By Professor R. Maiti Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Module03 Lecture08 Different Types of Valves-
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationInstallation Instructions, Pressure Regulator Series
Installation Instructions, Pressure Regulator 20517 Series Manual Model: 20517, L20517 Air motor Operated: F20517, LF20517 Hydraulic Motor Operated: G20517, LG20517 1. GENERAL ------------------------------------------------------------------------------
More informationControllers DR, DP, FR and DFR
Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller
More informationSHUR-LOK CORPORATION TECHNICAL SALES BULLETIN
Page 1 of 9 1. SCOPE: 1.1. This provides the minimum design, port preparation and installation and removal requirements for SLAS4383-XX-XX, SLF2002-XX-XX and SLF3004-XX-XX adapter reducer and is applicable
More informationPressure reducing valves (with check valve) X(C)G, XGL
Pressure reducing vlves (with check vlve) X()G, XGL 3- Pressure ontrol Vlves unctionl Symbols XG XGL X XG X Vlve is used to set pressure in brnch circuit lower thn pressure of the circuit. y connecting
More informationPressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)
Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationAir Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv
CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min
More information