1 E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86

2 merican Meter Series and Worker/Monitor Regulators Worker/Monitor sets are commonly used to provide overpressure protection. worker/monitor installation consists of a monitor with an external static connection and a worker with an internal static connection. The regulator selected to be the monitor is set at " to 5" w.c. above the worker. The external static connection is connected at a point free of turbulence and preferably a minimum of five pipe diameters downstream. Improved Features and Series Monitor onversion merican Meter offers four industrial monitor regulators the M, M, 88M and 8M. esign improvements now enable all models to be configured as Monitor Regulators. This change was effective with all and Series Regulators manufactured after January 99. The advantage is that two models of the same regulator need not be stocked. ll models are pre-machined to accept a monitor conversion kit. Refer to IMP 87 for kit numbers and installation instructions. When a regulator with an OPSO is converted to a monitor, a sense line must extend downstream of the worker, as shown in the diagram to the right. ONTROLLING MONITOR /" Typical Upstream Monitor Installation

3 The merican Meter Industrial Regulator Monitor onversion The body and valve head are premachined to allow easy conversion to a monitor model. See page for more information. Rugged onstruction Valve heads are ductile iron which prevents thread damage. vailable as -/" and " screwed, and " flanged connections. NSI, SP and IN connections available. Springs The Series spring ranges from.5" w.c. to 5 outlet pressure. Series spring ranges from / to 5 outlet pressure. See page. Interchangeable Orifice vailable in sizes from /" through -/" for a wide range of flow rates. One orifice is offered for both standard and OPSO models to minimize spare-parts inventory. OPSO Overpressure Shutoff for positive protection of public buildings such as schools, churches, etc. See page 5. Maintenance Three setscrews hold diaphragm case to the valve head, providing the easiest orifice and seat disc inspection in the industry. Pressure Taps The and Regulators have inlet and outlet pressure taps. Relief Vent " vent for Full Relief overpressure protection in three models, such as the 8. Partial Relief has " vent and Series has /". See page 7 for relief performances. urability ast-aluminum top and bottom diaphragm case for long service life. UPSO Snap-acting lever for underpressure shutoff protection when line pressure drops drastically.

4 merican Meter Regulators Other Features 8 Partial Relief Series low-pressure models have a maximum inlet pressure of 5 and offer outlet pressures ranging from.5" w.c. to 5. Series high pressure models allow a maximum inlet pressure of 5 and outlet pressures ranging from.5 to 5. The Series can be ordered as Full Relief, Partial Relief or No Relief Regulator as shown in the table. Series Regulators are non-relieving. oth models are available with Overpressure Shutoff, Underpressure Shutoff and monitor capabilities. Low Pres. Model imensions Numbers escription *E Standard Regulator.75" ".75" 6".5" M Standard Monitor Regulator.75" ".75" 6".5" 8 Partial Internal Relief Regulator.75" ".75" 6".5" 8 Full apacity Internal Relief Regulator.75" ".75" 6".5" 8 Underpressure Shutoff.75" ".75" 6".5" 8 Underpressure Shutoff with Partial Internal Relief.75" ".75" 6".5" 8 Underpressure Shutoff with Full Internal Relief.75" ".75" 6".5" 8 Overpressure Shutoff with Partial Internal Relief.75" " 5.6" 9.87".5" 8 Overpressure Shutoff with Full apacity Internal Relief.75" " 5.6" 9.87".5" 85 Overpressure and Underpressure Shutoff with Partial Internal Relief.75" " 5.6" 9.87".5" 85 Overpressure and Underpressure Shutoff with Full apacity Internal Relief.75" " 5.6" 9.87".5" 88 Overpressure Shutoff.75" " 5.6" 9.87".5" 88M Overpressure Shutoff with Monitor.75" " 5.6" 9.87".5" 89 Overpressure and Underpressure Shutoff.75" " 5.6" 9.87".5" High Pres. Model imensions Numbers escription *E Standard Regulator 8.9" ".75" 6".5" M Standard Monitor Regulator 8.9" ".75" 6".5" Underpressure Shutoff 8.9" ".75" 6".5" 8 Overpressure Shutoff 8.9" " 5.6" 9.87".5" 8M Overpressure Shutoff with Monitor 8.9" " 5.6" 9.87".5" 9 Overpressure and Underpressure Shutoff 8.9" " 5.6" 9.87".5" * " flange valve head is an option; contact Sales Office for information. No Relief Low Pressure E High Pressure E

5 merican Meter UPSO OPSO OUPSO Regulator Safety Features vailable Exclusively From merican Meter On Series and Industrial Regulators Pressure control and automatic shutoff devices for the protection of public buildings, schools, theaters, hospitals, etc. are available in one complete package on several and Series Industrial Regulator models (see page 5). Installing one of these regulators provides automatic protection against possible extreme variations in either inlet or outlet gas pressure. UPSO The UPSO (underpressure shutoff) models provide complete shutoff protection in case of severely interrupted inlet gas pressure. If the inlet or outlet pressure is severely interrupted, causing the regulator to stroke to a full-open position, the shutoff closes, providing complete system safety. The shutoff valve remains closed until manually reset. How The UPSO Operates When gas pressure under the main diaphragm falls below normal, the shutoff device is tripped and the spring, connected with the valve plunger, forces the valve seat against the orifice closing off gas flow. The UPSO must be manually reset to re-establish gas flow. Figure To reset the underpressure shutoff device (Figure ), unscrew the reset plug with a wrench. When it becomes free of the threads, pull it out until it engages the reset mechanism. With the wrench, turn the reset shaft clockwise until the reset mechanism is engaged. Hold firmly in this position until normal pressure is established under the diaphragm and downstream line, and regulator operation is restored. Screw in the reset plug and tighten. Overpressure Shutoff (OPSO) in cocked position Overpressure Shutoff (OPSO) in tripped position OPSO Overpressure shutoff regulator models prevent excessive gas pressure from entering a building causing a hazardous condition. The shutoff device closes if the regulator outlet pressure rises above a maximum set point or set pressure. How The OPSO Operates When line or static pressure increases to the specified overpressure shutoff setting, the pressure on the under side of the shutoff diaphragm over-balances the spring, forcing the diaphragm stem outward, releasing the plunger. This permits the shutoff spring to force the shutoff disc against the orifice, closing off gas flow. The OPSO assembly is part of the regulator but is not connected to the regulator operating mechanism. When selecting a shutoff spring, a minimum differential of " w.c. between normal operating pressures and the shutoff pressure setting should be provided. To reset the overpressure shutoff device, unscrew the seal cap, which opens the regulator orifice, permitting gas flow. Pull out on the seal cap until the overpressure shutoff device latches completely. Tighten the seal cap. o not trip the shutoff valve unless the seal cap is installed. OUPSO Overpressure and underpressure shutoff models combine both safety features for maximum protection. On these models, when the OPSO shuts off, the UPSO automatically trips, providing double assurance of positive gas shutoff. The overpressure shutoff device must be reset first followed by resetting the underpressure shutoff device. 5

6 apacity ata OUTLET PRESSURE INHES W.. OUTLET PRESSURE INHES W " Orifice - Set pressure 7." w.c. at SFH Spring Range 5.5" to 8." 9 5.5,,,, 5, 6, 7, 8, 9,,,,,, RTE OF FLOW - S..F.H. -.6 SP.GR.GS -.7 P.S.I F. " Orifice - Set pressure 7." w.c. at SFH Spring Range 5.5" to 8." 5 6.5,,,, 5, 6, 7, 8, 9,,,,,, RTE OF FLOW - S..F.H. -.6 SP.GR.GS -.7 P.S.I F. merican Meter Model 8 Regulator (-/" and " sizes) Full Relief Valve haracteristics Test performed with orifice valve blocked in wide open position. " screened vent-no vent pipe. Numbers in each circle indicate orifice size. 7" W.. - Set pressure / 7 5 / / " W.. - Set pressure / 5 / / 7 OUTLET PRESSURE (PSIG) 8 6 OUTLET PRESSURE (PSIG) 8 6 / / INLET PRESSURE (PSIG) INLET PRESSURE (PSIG) 9 PSIG - Set pressure / / 5 7 / 5 PSIG - Set pressure / 7 5 / / OUTLET PRESSURE (PSIG) 8 6 / OUTLET PRESSURE (PSIG) INLET PRESSURE (PSIG) INLET PRESSURE (PSIG) 9 6

7 -/" Series apacity ata SFH Gas.6 Specific Gravity 7P7.5" to 6" w.c. Set: 6" w.c. roop: " w.c. Max. ompound: " w.c. 7P9 8.5" to " w.c. Set: " w.c. roop: " w.c. 7P.5" to 8" w.c. Set: roop: 6" w.c. 7P to Set: roop:.6 -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,6,, 9 55 /,9,55,,, 6,85,,,,, 75,75,,85,,,5 7,,5,9,7,,7,,75,,6,6,,,,5,9,,,5,,,5,9,,,5,, 5,7 5,,,,,9,, 5 5,7 5,,,,,95,, 7,5 6, 6,,,,,55 7, 6, 6, 5,,,,6 9, 7,9 7,5 6, 5,,85,9 5 9,5 7, 7,5 6, 5,5,85,9 9, 8,7 7, 6,,6, 9, 8,6 7,5 6,,55,,75, 9, 7,7 5,9,85,,7 8,9 8, 5,,,, 9, 7,,,, 9, 7,5,, 9,,5 6, 9,,5 5,85 5, 7, 7, 8, 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,,,5 5,, 6, 5, 8, 7,6 9,,9,,55,5 6,6 8, 9,5,,5,, 6, 7, 9,,,,55,6 5, 6,5 7,5,,7,,, 5, 6,5 75,,,,9,,5,,5,85,5 5 5,55,,,,75, 5,7 5, 8, 7, 9,,7,6,, 6, 8, 9,6,5,,, 6, 7,6 8,,,9,5,,9 6,5 7,5,,5,,6, 5, 6, 7,,5,,,7,,,5,9,,, 9, 8, 5,,7,, 9, 8, 5,6,,7, 9,5 7,,,, 9, 7,,,9,5 9,6,5 6,, 9,,5,, 5,7 7, 8,,, 5,7 7, 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 6,,9,,,,,5 8, 6,65 5,6,7,,,, 5 7, 5,,9,,6,,75 9, 9, 8, 7, 6,,9,,5, 9, 7, 7, 5,9,7,9,5,, 8,7 7, 6,,7,9 5,,5 9,75 8,7 7,6 6,,,9,7,, 9, 7,,,5,9,,9, 9,5 7,,7,,,,6 9, 5,6, 5,,85,, 9,5 6,, 5,6,9,7,9 7,, 7, 5,,85,6 7,, 6, 6,, 9,,7 6 9,6 8, 7, 5, 9,,6 6,,5 5, 8,9 7,7,5 5,, 7,, 7, 8, 8, -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",,,9,9,,, ,6 5, 5, 5,,5,5,, 7, 5,6,,,7,,,, 7,9, 9,7 6,55 8, 6,55 8,, 5,, 5,,,,6, 5 9,5 7,6, 9,75 6, 7,6 6, 7,6, 6,, 5,,,85,,,,,,, 8, 9, 8, 9,,,9 6,,5,7,5,5,, 8, 9, 7, 8,7 5,,9 6,5,5 7, 7,,9,9 8,, 6 7, 7,,7, 8,9,9 5,5 5,5,85 6,,7 7,5 8, 6, 5,, 6,,7 7,5 8, -/" " 7" /" 5" /" " /",5,,,,,, 7P6 7, 5, 5,,5,7,,, 8,6 7, 6, 5, 5,,5,,6.5 to.5 9,9 8,6 7, 6, 6,7,,5, Set:.5,6 8,7 8, 8, 5,9,,6 roop:.,, 9,7 6,9 5,6,,,,, 7,,,,7, 9, 5,,5 6, 7,5 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line P8 5.5" to 8" w.c. Set: 7" roop: " Max. ompound: " w.c. 7P9 8.5" to " w.c. Set: " roop: " w.c. 7P to Set: roop:. 7P to 5 Set: 5 roop: ontact your merican Meter representative for inlet pressures above.

8 " Series apacity ata SFH Gas.6 Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P7,5,,,,6,5 /,5,,,9,,6 5, 9 5,6 5,,,,9,,65,.5" to 6" w.c. 8,9 6, 5,,,,,,6 Set: 6" w.c.,, 8, 5 7, 5,,,9,, roop: " w.c. 6,5,, 8, 6,,,,65 Max. ompound: " w.c. 6,5 5 6,, 9, 6,6,,95 9, 5,7,7 8,,6, 6, 8,5,5, 7,7 5,9 7, 9,6,85,,5 5,85 7, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P8,9,,6,7,, /,,,5,,,6 5,5 75 5,6,,,5,7,,6,5 5.5" to 8" w.c. 8,5 6, 5,,5,6,,,5 Set: 7" w.c.,, 8, 5 7, 5,,,9,, roop: " w.c. 5,7,,5 8, 6,,,,6 Max. ompound: " w.c. 7,5 6, 5 5,,5 9, 6,,,9 9, 9, 5,5, 7,,6, 6, 8,5,,5 7, 5,9 7, 9,6,,,5 5, 7, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P9, 5,,7,,,,,5,7,7,6,,,5 75, 7, 5,7 5,,5,6,,,5 8.5" to " w.c.,5 8,5 7, 5 6,,,,6,, Set: " w.c. 5,,, 8, 6,,,9,6 roop: " w.c. 9, 6, 5 5,, 8, 5,,,9 6 8,, 7,9,, 8, 7,,, 7,, 5,7 7, 9,,,,,,5 5,7 7, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7P9,7,5,,,,,,,5,,5, 9, 75, 6, 5,,,,,7,, 8.5" to " w.c.,6 7,6 6, 5 5,6,,6,5,, Set: " w.c. 9,,,6 9, 7, 5,,,,6 roop: " w.c. 9, 6, 5,, 7,9 5,5,7,9 7,7, 9,5 7,,, 7, 5, 9, 5,6, 8,, 7,, 6 7, 9,,5, 5,7 7, 8, For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 8 ontact your merican Meter representative for inlet pressures above.

9 " Series apacity ata SFH Gas.6 Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7,, 8, 5,5 7,7,6 8,,6 6,9,9 5, 5 5 6,5 6,,6, 7,,5 5, 7,9,5, 8,,, 6,5 8,6,5, 8,,,7,5 6, 7,6,,6 7,,5,,,7, 5,6 6,7 9,,5,,,6,9,,,,7 5, 7, 8, For Models With lue Holder Without OPSO For Models With Silver Holder Without OPSO For Models With Silver Holder With OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 7,6 6, 5, 5 5,,6,6,6,,,, 8,9 8, 7,6 5,9,,,6 5,,6 5,, 7,6 5,,7,9 9, 5,,5,5 9,5 7,,, 6,, 9, 5,6, 7,, 6,7, 6 7, 9,,6,5 5,, 7, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 5,,6,9 5,,7,5,6, 9, 7, 6, 6,5 5,,,9,,,, 9, 5 9, 6, 5,,,,6 8,5,,, 8, 7, 5,,6, 9, 7,5 5,5,, 7,6 5,,6,7,7 7,, 9, 6,, 6,7 5,9,6, 8,9, 8,, 9,,6 5,6, 6, 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /", 7,6,,, 5, 8,,5,, 5, 6,6 8,6, 7, 5 5 6, 5, 6,6 8,,,, 5, 6,6 8,,,,,5, 5, 8,,,5 9,,,5, 5, 8,,,5 9,,,,,6, 6, 8,,9, 75,,,,9,5, 6, 7,5 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO -/" " 7" 7" /" 5" /" " /" 8, 6, 5, 5, 5,,,,,, 8,6 7, 5 7, 7, 5,,,,,5, 9, 8,7 8,7 6,5 5,,, 5,,,, 8, 7, 5,,9 7, 5,6 5,6, 9,5 6,5,5 6 5,5, 8,9,9 7,, 6,,7 7,5 8, 7P.5" to 8" w.c. Set: roop: 6" w.c. 7P to Set: roop:. 7P6.5 to.5 Set:.5 roop:. 7P to Set: roop:.6 7P to 5 Set: 5 roop: For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 9 ontact your merican Meter representative for inlet pressures above.

10 -/" Series apacity ata SFH Gas.6 Specific Gravity " Series apacity ata SFH Gas.6 Specific Gravity 7P / to Set: roop: 6" w.c. 7P to -/ Set: -/ roop: / 7P -/ to 5 Set: 5 roop: 7P 5 to Set: roop: 7P to 5 Set: 5 roop: ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 7, 5,9,5,5,,9,9, 5,7 7,5 6,,7,,5,9,, 8,7 7, 6, 5,9,5,7,5 8,,9, 7, 6,5,,,5,,6 7,9 7,9 7,65 5,,7, 5 7,5, 9,9 8, 5,5,7,,,75, 9,5 7,,5, 8,,, 6,,5, 5,,,, 9, 5,7, 7, 5, 9, 5,7, 5,6,9,,6 7,, 9,, 7,, 6, 6,,5 9,,6 6 6, 9,,6 8, 8, 5,, 5,9, 5,9, 7,,9 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /" 6, 5,,,,5,, ,5 5,,9,,,,7 9,5 8, 7,5 6,5 5,5,,7,,, 8, 6, 5,,,7,,,6 9, 8, 7,5 5,5,6, 5 9,,7,7 9, 7,5 5,,6, 5,,5,, 8,9 6,,5, 7,,, 9,5 6,,5, 6,5,6,,5 9, 5,7, 5,, 8,9 5,7, 7,7 5,,,9 7,, 9, 6,7, 7,, 8, 7,5,7 9,6,6 6 6, 9,6,6 6,, 5,9, 5,9, 7,, 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /", 8, 6,6 6,,,,,,7 9, 7,5 6,,,6,,,, 9, 8, 6,7 5,5,, 5 6,,, 8, 6,7 5,,, 6,,,,7 8, 7,,, 6,7,6, 8,7 6,,, 8, 5,,, 9,5 5,5, 8,9 5,5, 9, 5,5, 9,5 7,,9, 6,7, 9,6 5,7, 6,7, 9, 5, 9,,6 6 6, 9,,6 9,, 5,9, 5,9, 7,,6 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /", 8,5 7, 6, 5,,,,5 5,7 8,7 7, 6, 5,,7,,5,,5 9, 8, 6,6 5,,5,,,, 8, 6,7 5,,5, 6,,5, 9,7 7,7 5,, 7,7 5,, 9, 7, 5,, 7,6 5,,, 6,6, 9, 5,7, 9,5 6,6, 7,, 9,,6 6 8,, 9,,6 7,,7 5,9 7,,7 5,9, 7,, 7, 8,5 8,5 ll Models With lue Holder -/" " 7" /" 5" /" " /" -/" " 7" /" 5" /" " /",9, 8,5 7, 5,9 5,,,,9, 8,9 7,5 6,,5,, 5,,9, 9,5 7,,9, 7,6,6, 9,7 7,,9, 7,9 5,,, 6,, 9, 5,5, 9,5 6,, 8,, 9,,6 6 8,,5 9,,6 9,5,7 5,9 7,6,7 5,9,5 7,,5 7, 8,5 8,5 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. ontact your merican Meter representative for inlet pressures above.

11 merican Meter Regulator Parts SERIES LOW PRESSURE REGULTOR PRESSURE SPRINGS.5" to 6" w.c. 7P7 Red 5.5" to 8" w.c. 7P8 Orange 8.5" to " w.c. 7P9 Yellow.5" to 8" w.c. 7P Green to 7P lue.5 to.5 7P6 rown and lue to 7P rown and Green to 5 7P lack and Green SERIES HIGH PRESSURE REGULTOR PRESSURE SPRINGS.5 to 7P rown and White to.5 7P Purple and White.5 to 5 7P Orange and lack 5 to 7P lack to 5 7P Yellow and Green OPSO SHUTOFF SPRINGS " to 8" w.c. 77P75 Red and Purple to 77P76 Red and rown to 77P77 Purple to 5 77P78 Orange and Yellow 5 to 8 77P79 Orange and Green 8 to * 77P78 Orange and Yellow to * 77P79 Orange and Green *To achieve these ranges, reducing ring 766P must be used. / SERIES REGULTOR ORIFIE SIZES Valve Head Size Part Number -/" and " /" 798P -/" and " " 798P -/" and " /" 798P -/" and " 5" 798P -/" and " /" 798P -/" and " 7" 798P5 -/" and " " 798P6 -/" and " -/" 798P7 These orifices are double-sided and work with both OPSO and non-opso Models. REGULTOR REPIR KITS 799K Valve Seat isc 7P7 ody 7P6 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 77P Vent Screen 7P8 Isolation Plate (I..) 7P6 Isolation Plate (O..) 7P57 Valve Plunger 7P9 Valve Head Setscrew 7P6 7P6 7P5 Isolation Plate (I..) 7P78 Gasket 79P87 Gasket 79P9 Kit Services:, M,, 8, 8M, 9 799K** Isolation Plate 7P 7P78 7P57 7P9 Kit Services ll Regulators **For use in units built after January, K7** Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P68 ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 7876P5 Vent Screen 7P5 Valve Head Setscrew 7P6 7P6 7P5 Gasket 79P9 Kit Services: 8, 8, 8, 85 **For use in units built prior to pril, K5** Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 76P Vent Flapper Retainer 7876P5 Vent Screen 7P5 Valve Head Setscrew 7P6 7P6 7P5 Gasket 79P9 Kit Services: 8, 8, 8, 85 **For use in units built after pril, K6 Valve Seat isc 7P7 ody 7P6 Seal Plug 7P7 iaphragm 7P ody Screw 7P ody Nut 7P Vent Flapper 777P Vent Flapper Retainer 7876P5 Vent Screen 7P Vent Screen Retainer 7876P Isolation Plate (I..) 7P6 Isolation Plate (O..) 7P57 Valve Plunger 7P9 Valve Head Setscrew 7P6 7P6 7P5 Isolation Plate (I..) 7P8 Kit Services: 8, 8, 8, 8M, 85, 85M,, M, 8, 88, 88M, K Valve Seat isc ody Seal Plug Kit Services ll Regulators 7P7 7P6 7P7

12 merican Meter Regulator ssembly Positions Valve Head Position STNR VENT POSITION Valve Head Position STNR VENT POSITION Valve Head Position STNR VENT POSITION STNR VENT POSITION Valve Head Position Full-Open Regulator apacity For sizing downstream relief valves, use the following formulas to determine the regulator full-open capacity: For critical flow rates For sub-critical flows Q =.5 x P G Key: Q = Maximum capacity of regulator = Orifice constant, see table P = absolute pressure (a) P = Outlet absolute pressure (a) h = ifferential pressure (P - P ) G = Specific gravity of gas Q = P h G Orifice /" " 6 /" 5" 6 /" 8 7", ",5 -/",5 STNR VENT POSITION Regulator ssembly Number VLVE HE POSITION * VLVE HE POSITION OPSO VENT POSITION ** ** ** * FOR MOELS USING OPSO ONLY. ** UNLESS OTHERWISE SPEIFIE, VLVE HE POSITION "" WILL E SUPPLIE. STNR VENT POSITION Shipping Weights Net Wgt. escription (Lbs.) -/" x -/" Screwed * 9-/ -/" x -/" Screwed 88 -/ -/" x -/" Screwed * 5-/ -/" x -/" Screwed 8 7-/ " x " Screwed * 9-/ " x " Screwed 88 -/ " x " Screwed * 5-/ " x " Screwed 8 7-/ * ll Models except OPSO. For Flanged Models add -/ lbs. Ordering Information. Model number.. Size of connection: screwed or flanged.. and outlet pressures.. Volume in scfh. 5. Kind of gas and specific gravity. 6. ssembly position. 7. Orifice size. 8. OPSO spring part numbers, if required. omplete Family of Gas Measurement, Pressure Regulation, and Testing Systems Turbine Gas Meters High-performance meters provide accurate measurement of highvolume gas flow. Turbines are available from " to " line sizes and line pressures up to g. See bulletin S 5 for more information. Rotary Gas Meters RPM Series Rotary Meters are designed for commercial and industrial loads to provide accurate flow measurement and outstanding performance in the most adverse conditions. See bulletin S 55 for more information. iaphragm Meters merican Meter s compact, lightweight, aluminumcase meters are designed to provide positive displacement accuracy for industrial or commercial loads. See bulletin S 5 for more information. Pilot-Loaded Regulators PFM industrial regulators are designed for applications requiring medium-to-high capacity, extremely precise outlet-pressure control, and fast response to changing loads. See bulletin S 855 for more information. merican Meter ompany is committed to a program of continuous quality enhancement. ll equipment designed and manufactured by merican Meter ompany benefits from the company s quality assurance standards, which are approved to ISO 9 or ISO 9. merican Meter ompany has a program of continuous product development and improvement; and, therefore, the information in this bulletin is subject to change or modification without notice. MERIN METER NIN METER Welsh Road 7 erry Road, West uilding One Milton, Ontario L9T X6 anada Horsham, P 9- U.S.. Phone: Phone: 5- Fax: Fax: 5-89 Website: americanmeter.com Printed in U.S.. ore 5 8/

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG A C E D SB 8551.3 Model 1800 PFM Series Regulator For Constant Precise Fixed Factor Measurement From 0.5 to 30 G AMC Quality System QMI is Accredited by: C R E D I T ISO 900 Registered R E ANSI RAB G I

More information

1800B2 and 1800B2-HC Series Service Regulators. Technical Bulletin

1800B2 and 1800B2-HC Series Service Regulators. Technical Bulletin 800 and 800-H Series Service Regulators Technical ulletin 800 and 800-H Series Service Regulators 0 lster merican Meter The 800 Series pressure regulators are designed to control natural gas, air, nitrogen,

More information

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council

More information

Model 1800 PFM Series Regulator. Technical Bulletin

Model 1800 PFM Series Regulator. Technical Bulletin Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane

More information

1800CPB2 Service Regulators

1800CPB2 Service Regulators SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,

More information

1800C & 1800C-HC Service Regulators

1800C & 1800C-HC Service Regulators SB-855.8 800 & 800-H Service Regulators Maximum Pressure 5 PSIG 800 Regulator Information General Information The merican Meter Series 800 pressure regulators are designed for natural gas applications

More information

1800C and 1800C-HC Service Regulators

1800C and 1800C-HC Service Regulators SB 855.9 800C and 800C-HC Service Regulators Maximum Pressure 5 Table of Contents 800C Regulator Information...................... 800C-HC Regulator Information.................. 800C and 8C Service Regulators...............

More information

1800CPB2 Pilot-Loaded Service Regulators

1800CPB2 Pilot-Loaded Service Regulators 1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................

More information

Model 1800 PFM Series Regulator

Model 1800 PFM Series Regulator Model 800 PFM Series Regulator Model 800 PFM Series Regulator 0 Elster 800 PFM Series Regulator losing Springs For improved lock-up performance Low differential High differential (See losing Spring chart

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators September 12 299H Series Pressure Reducing Regulators Inlet Pressure up to psig / 1 bar Compact ±1% Accuracy for Fixed Factor Billing (PFM) Rugged Construction Integral Pilot Easy to Maintain W713 Figure

More information

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG SB-8506. B Service Regulators Maximum Inlet Pressure 5 PSIG Measurement Engineers Since 86 www.americanmeter.com B Service Regulators General Information The American Meter Series B pressure regulator

More information

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7 Models 461-S, 461-8S and 461-12S Regulators R-1330 Rev. 7 461-S, 461-8S and 461-12S Regulators The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution

More information

1800C and 1800C-HC Series Service Regulators

1800C and 1800C-HC Series Service Regulators 1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief

More information

Regulator from 1800 B series

Regulator from 1800 B series Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds

More information

1200B2 Series Service Regulators. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual 00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available

More information

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact. Bulletin 71. D3X01 99H Series May 18 99H Series Pressure ucing Regulators I nlet Pressure up to psig / bar Compact Integral Pilot Figure 1. 99H Series Pressure ucing Regulators High Capacity Robust O utlet

More information

Series 100 Slam Shut Valve. Technical Bulletin

Series 100 Slam Shut Valve. Technical Bulletin Series 100 Slam Shut Valve Technical Bulletin 02 Elster The Series 100 Slam Shut protects gas installations against overpressure conditions by automatically shutting off the gas flow. General Information

More information

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators CSB400 Series Commercial / Industrial Pressure Reducing Regulators Bulletin 71.1:CSB400 April 2011 CSB400 SERIES PRESSURE REDUCING TYPICAL CSB403 WITH INTEGRAL TRUE-MONITOR TYPICAL CSB404 WITH INTEGRAL

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

North American 7339 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across

More information

Type 299 Pressure Reducing Regulators

Type 299 Pressure Reducing Regulators Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks

More information

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators October 2015 CSB400 Series Commercial / Industrial Pressure Reducing Regulators P1424 TYPE CSB400 PRESSURE REDUCING P1426 TYPICAL TYPE CSB403 WITH INTEGRAL TRUE-MONITOR P1425 TYPICAL TYPE CSB404 WITH INTEGRAL

More information

SR100 Series Service Regulators. Technical Bulletin

SR100 Series Service Regulators. Technical Bulletin SR00 Series Service Regulators Technical Bulletin Model SR00 Series Regulator 0 Elster American Meter The compact, high capacity SR service regulator is designed for residential or light commercial/industrial

More information

Hawk Mechanical Alley 111 Submittal Log - Hawk Job #: /21/2014. Submittal Status

Hawk Mechanical Alley 111 Submittal Log - Hawk Job #: /21/2014. Submittal Status Hawk Mechanical Alley Submittal Log - Hawk Job #: 65 //04 Submittal Status Section Sub-Section Tag Description Manufacturer Model # Approval Status Submitted Revision Returned 4900 4900 Facility Natural

More information

American Meter Co. Five-Year Limited Warranty Industrial Regulators

American Meter Co. Five-Year Limited Warranty Industrial Regulators Read carefully and follow all instructions shipped with this regulator. The incorrect specification or installation of this equipment could result in escaping gas, and pose a potential explosion hazard.

More information

RB 4000 Commercial & Industrial Regulator

RB 4000 Commercial & Industrial Regulator R 4000 ommercial & Industrial Regulator The R 4000 pressure regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants and all installations where accurate

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh

Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh SB 3510.3 Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh AMC Quality System QMI is Accredited by: ISO 9002 Certified Dutch Council for Accreditation

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings BR-G-REG-13-30-03-02-A* 461-S, 461-8S and 461-12S Regulators Brochure Introduction The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution and industrial

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay

More information

Noth American 7347 High Pressure Gas Regulators

Noth American 7347 High Pressure Gas Regulators Combustion Noth American 7347 High Pressure Gas s Bulletin 7347 7347 s reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across the regulator (see

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

B34 Series Regulator Commercial and Industrial Regulator

B34 Series Regulator Commercial and Industrial Regulator B34 Series Regulator Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34 is particularly

More information

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications Bulletin 71.2 D1092X012 Type EZL October 2017 Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications W8962_1 Figure 1. Type EZL Pressure Reducing Regulator Features Low Differential

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

Types S100K and S102K Pressure Regulators

Types S100K and S102K Pressure Regulators Instruction Manual Form 5624 Types S0K and S2K 01/01 Types S0K and S2K Pressure Regulators W7478-1 Figure 1. Types S0K and S2K Pressure Regulator Introduction Scope of Manual This manual provides instructions

More information

Radial Flow Valves. Installation Operation Control Manifold Control Loops Repair Parts. ANSI Class 150, 300 and 600 IM

Radial Flow Valves. Installation Operation Control Manifold Control Loops Repair Parts. ANSI Class 150, 300 and 600 IM IM 9730.1 ANSI Class 150, 300 and 600 Radial Flow s Installation Operation Manifold Loops Repair Parts AMC Quality System QMI is Accredited by: ISO 9002 Registered Dutch Council for Accreditation INDEX

More information

MODEL 274 GAS PRESSURE REGULATOR

MODEL 274 GAS PRESSURE REGULATOR Edition GD274.06.USA BRYAN DONKIN RMG USA Serving the Gas Industry WORLDWIDE Applications Primarily utilized for commercial and industrial applications For natural gas and all non-corrosive gaseous media

More information

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

CS800 Series Commercial / Industrial Pressure Reducing Regulators

CS800 Series Commercial / Industrial Pressure Reducing Regulators Instruction Manual D103124X012 CS800 Series April 2018 CS800 Series Commercial / Industrial Pressure Reducing Regulators P1235 P1234 TYPE CS800 REGULATOR TYPE CS800IQ WITH HIGH CAPACITY RELIEF P1521 TYPE

More information

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018 ulletin 71.6 D102356X012 pril 2018 Type OSE Type OSE Slam-Shut Valve P2223 Figure 1. Type OSE Slam-Shut Valve Features and enefits Overpressure and Underpressure Protection Type OSE can be equipped for

More information

MODEL 273PL GAS PRESSURE REGULATOR

MODEL 273PL GAS PRESSURE REGULATOR Edition GD273PL.06.USA BRYAN DONKIN RMG USA Serving the Gas Industry WORLDWIDE Applications Primarily utilized for commercial, industrial and multi-installation applications For natural gas and all non-corrosive

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device Instruction Manual Form 5492 Types S108K and S109K May 1999 Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device Introduction Fisher regulators must be installed, operated

More information

Type FEQ Slam-Shut Valve

Type FEQ Slam-Shut Valve Instruction Manual Form 5865 Type FEQ December 2012 Type FEQ Slam-Shut Valve Contents Introduction...1 Principle of Operation...1 Specifications...2 Installation...2 Commissioning...7 Adjustment...9 Shutdown...10

More information

MEGR-1912 Instruction Manual

MEGR-1912 Instruction Manual MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Type OS2 Slam-Shut Device

Type OS2 Slam-Shut Device Instruction Manual D102778X012 Type OS2 April 2018 Type OS2 Slam-Shut Device! Warning Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators Product Line Brochure J0B Effective Date 2/01 Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators P R O D U C T L I N E O V E R V I E W Regulator

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators Instruction Manual D102684012 299H Series May 2018 299H Series Pressure Reducing Regulators! Warning Failure to follow these instructions or to properly install and maintain this equipment could result

More information

RB 4700 Commercial & Industrial Regulator

RB 4700 Commercial & Industrial Regulator RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.

More information

SPRING-LOADED GAS PRESSURE REGULATOR

SPRING-LOADED GAS PRESSURE REGULATOR MODEL 274 REGULATOR MODEL 852 REGULATOR Serving the Gas Industry Worldwide BD USA MODEL 1 274 SPRING-LOADED GAS PRESSURE REGULATOR Technical Manual July 2010 BRYAN DONKIN USA Introduction, Characteristics,

More information

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection GE Oil & Gas Mooney * Flowgrid * Slam Shut Regulator Delivering accuracy, performance and protection Industries Gas transmission Gas distribution Midstream gas Gas processing Applications Gas pipelines

More information

North American 7337A/B/C-4 High Pressure Gas Regulators

North American 7337A/B/C-4 High Pressure Gas Regulators Combustion North American A/B/C-4 High Pressure Gas Regulators Bulletin A/B/C-4 A-4, B-4 and C-4 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections

More information

EZH and EZHSO Series Pressure Reducing Regulators

EZH and EZHSO Series Pressure Reducing Regulators Bulletin 71.2 D1081X012 EZH and EZHSO Series December 2017 EZH and EZHSO Series Pressure Reducing Regulators Figure 1. Type EZH Pressure Reducing Regulator Specifications The Specifications section lists

More information

safety Shut-Off Valve HON 721

safety Shut-Off Valve HON 721 safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety

More information

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications August 2015 290 psig / 20.0 bar Inlet/Outlet Rating Bubble Tight Shutoff Low Differential Absolutely No Atmospheric Bleed

More information

SB AXIAL FLOW VALVES

SB AXIAL FLOW VALVES SB9509.3 AXIAL FLOW VALVES The improved technology for pressure regulation The American Axial Flow Valve provides pressure and flow control in high capacity pipelines. It can be used for pressure regulation,

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators Instruction Manual D102684012 299H Series May 2017 299H Series Pressure Reducing Regulators! Warning Failure to follow these instructions or to properly install and maintain this equipment could result

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators Instruction Manual Form 5497 299H Series January 2014 299H Series Pressure Reducing Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result

More information

Safety Shut-off Valve SSV

Safety Shut-off Valve SSV Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications Instruction Manual Form 5753 Type HSR October 2003 Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications W8648 Figure 1. Type HSR Pressure Regulator Introduction

More information

WW-730. Pressure Sustaining/Relief Control Valve

WW-730. Pressure Sustaining/Relief Control Valve WW-730 Pressure Sustaining/Relief Control Valve Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 730 Pressure Relief / Sustaining Valve is an automatic control valve designed to

More information

66 Series Direct-Operated Regulators and Vacuum Service Equipment

66 Series Direct-Operated Regulators and Vacuum Service Equipment 66 Series Direct-Operated Regulators and Vacuum Service Equipment November W193/IL Figure 1. Exterior of Type 66 or 66Z Regulator Introduction Fisher 66 Series direct-operated pressure-reducing regulators

More information

MODEL 240 GAS PRESSURE REGULATOR

MODEL 240 GAS PRESSURE REGULATOR Edition GD240.06 BRYAN DONKIN RMG CANADA LIMITED Serving the Gas Industry WORLDWIDE Applications Primarily utilized for residential, commercial and industrial applications For natural gas and all non-corrosive

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate

More information

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax 6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation

More information

RESIDENTIAL REGULATORS

RESIDENTIAL REGULATORS RESIDENTIAL REGULATORS Type B NG Process Management TM B NG Regulators Description! BODY RESISTANT TO HIGHER PRESSURES Various Springs Adaptable to various fluids (Natural Gas, LPG, Manufactured Gas, etc.)!

More information

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 www.apq.com.es EU Product / Spain DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 Cod. RISUT5000A1 Cod. RISUT5000D1 DESCRIPTION The Suton 50001 Regulator is designed for use in distribution networks

More information

Model 141-A Field Regulator. R-1311 Rev. 9

Model 141-A Field Regulator. R-1311 Rev. 9 Model 4-A Field Regulator R-3 Rev. 9 4-A Field Regulator The 4-A Field Regulator is for high pressure work such as feeding intermediate and small volume loads from gas transmission lines. Use this field

More information

Type Cronos Pressure Reducing Regulator

Type Cronos Pressure Reducing Regulator Type Cronos Pressure Reducing Regulator March 2002 E0838 Figure 1. Type Cronos Regulator Features! Control ccuracy Keeps constant inlet pressures to downstream equipment by accurately controlling system

More information

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator May 2010 Figure 1. CP200 Series Pressure Loaded Regulator Features and Benefits Wide Range of NPT Body Sizes Easy to Install

More information

RB4000 Series Regulator Commercial & Industrial Regulator

RB4000 Series Regulator Commercial & Industrial Regulator Gas RB4000 Series Regulator Commercial & Industrial Regulator Applications The RB4000 regulator is designed for gas supply networks, district station regulation, industrial service regulation, and all

More information

Norval Pressure regulator

Norval Pressure regulator Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable

More information

64 Series Pressure Reducing Regulators

64 Series Pressure Reducing Regulators Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,

More information

Type 99 Pressure Reducing Regulators

Type 99 Pressure Reducing Regulators Type 99 Pressure Reducing Regulators Bulletin 71.2:99 July 2008 W6527 W2676 D100138X012 www.emersonprocess.com/regulators Features Wide Variety of Applications Natural gas distribution systems, gas supply

More information

Slam Shut Valves SCN

Slam Shut Valves SCN Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever

More information

CL838 Series Twin Parallel Flow Service Regulators

CL838 Series Twin Parallel Flow Service Regulators CL838 Series Twin Parallel Flow Service Regulators The CL838 series regulators is a single valve body regulator with large twin diaphragm cases that are pilot loaded to insure a high degree of accuracy

More information

Type EZH Relief or Backpressure Regulator

Type EZH Relief or Backpressure Regulator Bulletin 71.4 D103574X012 Type EZH December 2017 Type EZH Relief or Backpressure Regulator P1668 Figure 1. Type EZH Relief Valve or Backpressure Regulator Features Bubble Tight Shutoff A knife-edged metal

More information

RHPS Series PRV 6 User Manual

RHPS Series PRV 6 User Manual RHPS Series PRV 6 User Manual Read the complete manual before installing and using the valve. 1 WARNING Before removing a valve from the system for service, you must depressurize system purge the system

More information

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002 Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact

More information

RB4000 Series Regulator Commercial & Industrial Regulator

RB4000 Series Regulator Commercial & Industrial Regulator Gas RB00 Series Regulator Commercial & Industrial Regulator Applications The RB00 regulator is designed for gas supply networks, district station regulation, industrial service regulation, and all applications

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

RS(H)20, 25 USER MANUAL

RS(H)20, 25 USER MANUAL RS(H)20, 25 USER MANUAL Read the complete manual before installing and using the regulator. WARNING Before removing a regulator from the system for service, you must depressurize system purge the system

More information

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2 utomatic filling units series 55 cert. n ISO 9 5/5 G Replaces 5/ G unction he automatic filling unit is a device consisting of a pressure reducing valve with compensating seat, an inlet strainer, a shut-off

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Model CYCLE GARD II, CI & CNA YOUR PRODUCT INFORMATION: Model Number: Date: Serial Number:

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information