F68G - Olympian Plus plug-in system General purpose filter

Size: px
Start display at page:

Download "F68G - Olympian Plus plug-in system General purpose filter"

Transcription

1 > > Port size: /... / (ISO G/ PTF) > > Olympian Plus plug in system > > Large filter element area provides minimum pressure drop > > Effective liquid removal and positive solid particle filtration Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (6 psi) Filter element: μm (standard), 5 μm optional Port sizes: /,, / or / Flow: See table below Drain: Manual or automatic Automatic drain conditions: Pressure to close drain: >, bar (. psi) Pressure to open drain: <, bar (. psi) Minimum air flow to close drain:,6 dm /s (. scfm) Service life indicator: Available on request Bowl size:,5 litre (7 fluid oz standard); litre ( fluid oz optional) Ambient/Media temperature: C ( F) Air supply must be dry enough to avoid ice formation at temperatures below + C (+5 F). Materials: Body, yoke and bowl: Aluminium Liquid level indicator: Pyrex Element: Sintered plastic Elastomers: BR Technical data - standard models Symbol Port size Size Drain Filter element (µm) Flow *) (dm /s) Weight (kg) G/ Manual 6,5 F6G-6G-MR G Basic Manual, F6G-G-MR G / Manual, F6G-AG-MR G / Manual, F6G-BG-MR Without yoke Manual F6G--MR G/ Automatic 6,5 F6G-6G-AR G Basic Automatic, F6G-G-AR G / Automatic, F6G-AG-AR G / Automatic, F6G-BG-AR Without yoke Automatic F6G--AR *) Typical flow with inlet pressure 6, bar ( psi) set pressure and,5 bar (7 psi) drop from set. Model without notice, the specifications given in this document. ( - f) 5 IMI International s.r.o. 7/7 en.6..

2 Option selector Version Long bowl ( litre) E Standard bowl (,5 litre) G Port size / 6 / A / B Without yoke Thread PT A ISO G parallel (standard) G Without yoke (standard) Service life indicator Without (standard) Mechanical D Electrical E F6 - - Element 5 μm μm (standard) Bowl,5 l with liquid level indicator (standard) l with liquid level indicator U *),5 l no liquid level indicator M l no liquid level indicator C *) Drain Automatic Manual, spindle type R *) Units with litre bowl are available only with E version only; therefore substitute E at the th digit and U or C at the th position. A M Flow characteristics Port size, µm element Pressure drop Δp psi 6 bar,6,,,5 (6) Inlet pressure bar (psi), (5) 6, (), (6), (5) 6 dm /s 6 scfm Air flow en.6.. without notice, the specifications given in this document. ( - f) 5 IMI International s.r.o. 7/7

3 F6G - Olympian Plus plug-in system Accessories, service kit and gauges 5 Accessories Single yoke Thread 5 Double yoke End connector kit Single yoke non threads / Shut-off valve Threaded inlet only Threaded outlet only Y6A-6G T6H-6GC-B G/ Y6A-6G T6H-6GB-B G Y6A-G- Y6A-G T6H-GB-B T6H-GC-B G / Y6A-AG T6H-AGB-B Y6A-AG- T6H-AGC-B G / Y6A-BG- Y6A-BG- 55- T6H-BGB-B T6H-BGC-B Bracket mounting / PTF Y6A-6A- Y6A-6A T6H-6AB-B T6H-6AC-B --7 PTF Y6A-A- Y6A-A T6H-AB-B T6H-AC-B --7 / PTF Y6A-AA- Y6A-AA T6H-AAB-B T6H-AAC-B --7 / PTF Y6A-BA- Y6A-BA T6H-BAB-B T6H-BAC-B --7 ut 55- Porting block (G/ & G/) /7 manual drain automatic drain F6G-KITM F6G-KITA -6- (/ & / PT) without notice, the specifications given in this document. ( - f) 5 IMI International s.r.o. en.6..

4 Dimensions Dimensions in mm Projection/First angle 7 5 # (6 #) 7 (5) 65 # ( #) ,5 7,5, ,5 7,5,5 (6) Manual drain ø 6 6 Automatic drain 5 # Minimum clearance required to remove bowl ( ) values for litre bowl Main ports /,, / or / Service life indicator optional Plus mm for ports / or / Sight glass Single yoke with bracket Double yoke with bracket 5 For / and / ported yokes add mm For / and / ported yokes add mm en.6.. without notice, the specifications given in this document. ( - f) 5 IMI International s.r.o. 7/7

5 / Shut-off valve Porting block Dimensions in mm Projection/First angle 5 6 / ø / For / ported yokes add 5 mm Two additional plugged G/ ports Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, IMI International s.r.o. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 7/7 without notice, the specifications given in this document. ( - f) 5 IMI International s.r.o. en.6..5

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators >> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure

More information

B74G - EXCELON Modular System General purpose filter/regulator

B74G - EXCELON Modular System General purpose filter/regulator > Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

R18 General purpose pressure regulators

R18 General purpose pressure regulators > > Port size: / & (ISO G, PTF) > > Can be installed at any point in the compressed air system without regard to accessibility pilot regulator can be installed in the most convenient location > > Accurate

More information

R84G - Excelon Plus Modular System Pressure regulators

R84G - Excelon Plus Modular System Pressure regulators > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Regulators/valves Compressed air regulators Without filter

Regulators/valves Compressed air regulators Without filter Regulators/valves Compressed air regulators Regulators/valves Compressed air regulators Without filter 0 to 7 bar 0 to 7 bar controllable, with automatic vent, admission pressure-independent. Operating

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing

More information

KM/31000 (Stainless steel end plates) Air bellows, single acting

KM/31000 (Stainless steel end plates) Air bellows, single acting KM/ (Stainless steel end plates) > > Ø... / inch (... mm) > > Very easy to install no alignment problems > > Almost frictionless operation > > No maintenance or lubrication > > Typical applications; actuator,

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Symbols. Bowl type Poly bowl with bowl guard G Metal bowl without sight gauge M. Drain type 5μ Element

Symbols. Bowl type Poly bowl with bowl guard G Metal bowl without sight gauge M. Drain type 5μ Element P Series Mini Particulate Filter - P Symbols Options: P F A Thread type BSPP BSPT Port size /8 / type Poly bowl with bowl guard G Metal bowl without sight gauge M Mounting 9 lement Drain type μ lement

More information

Series K Air service units G 1/8, G 1/4

Series K Air service units G 1/8, G 1/4 Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece

More information

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment

More information

Air service units series K G1/8, G1/4

Air service units series K G1/8, G1/4 Air service units series K Series FK Filter 12.011 Series RK Pressure regulator 12.012 Series FRK Filter/regulator 12.013 Series OK Lubricator 12.014 Series FROK Two piece air service unit 12.015 Series

More information

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4 V7 V7 EXCELO QUIKCLMP SYSTEM Pressure relief valves V7, V7-1/... 3/ Excelon design allows in-line installation or modular installation with other Excelon products Push to lock adjusting knob with tamper

More information

Non-Return Valves T55 Series

Non-Return Valves T55 Series T55 Series In-Line, Non-Return Valves M5, 1 8", 1 2" BSPP, BSPT, NPT Permit free flow of air in one direction only Simple, reliable design Light weight Silicone free Low cracking pressure Technical ata

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

PARTICULATE FILTER/REGULATOR

PARTICULATE FILTER/REGULATOR PRTICULTE FILTER/REGULTOR High flow with a wide range of adjustable output pressure ranges Optional low profile integrated gauge, Optional extended temperature range of -40 C to +80 C Threaded ports allow

More information

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6 List of Contents VMA System description Individual Units Pre-Filters 3 Micro-Filters Activated-Charcoal-Filters 5 Combinations Accessories and Main spare parts Service Units G 1 / Pre-Filter Micro-Filter

More information

Modular Type Regulators

Modular Type Regulators Modular Type Regulators Series AR AC Regulator Series AR Port size Options AFARAL, 1/4 Bracket AFAR AWAL AR4-A, 1/2 Round type pressure gauge With set nut (for panel mount) AFAFMAR P.45 to 5 AR4-6-A ot

More information

Air service units series Y G1/4 to G1

Air service units series Y G1/4 to G1 Air service units series Y Series FY Filter, 12.071 Series RY+ RYP Pressure regulator, 12.076 Series FRY Filter/regulator, 12.080 Series OY Lubricator, 12.083 Series FROY Filter, Regulator, Lubricator

More information

Quick Release Couplings 233 Series

Quick Release Couplings 233 Series Quick Release ouplings 233 Series 4mm - 9mm I/ hose 1 8" - 1 4" SP thread Low pressure drop across coupling High flow rate ompact construction One hand operation Robust construction Various connection

More information

Model range*1) Switching pressure difference

Model range*1) Switching pressure difference Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4 Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual

More information

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life Water Separator Series AMG Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

KM/ Stainless steel air bellows Single acting Ø 220 to 400 mm

KM/ Stainless steel air bellows Single acting Ø 220 to 400 mm KM/ Stainless steel air bellows Single acting Ø to mm Stainless steel end plates Frictionless operation No maintenance or lubrication Ideal for short stroke, high-force applications High isolation level

More information

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body NEW - HZE Air Treatment Units CHARACTERISTICS Ambient temperature Working pressure Max pressure Body Knob Ring nut Bowl Bowl guard Filter element Seals Springs Diaphragm CODIFICATION KEY H Z E B 8 G +6

More information

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating

More information

Air-service devices, Series MU1

Air-service devices, Series MU1 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Air-service devices, Series MU1 Technical data Pressure regulator valve, MU1, G 1 Technical Data Type Operating

More information

C 0G 00 N/US

C 0G 00 N/US G, GP, G, GP In-line flow regulators (block form) Uni-directional Ø /... / inch, Ø 4... mm High flow performance In-line or panel mounting Adjustment can be locked aptive regulator needle will not blow

More information

FILTER REGULATOR. We produce with artistic attitude.

FILTER REGULATOR. We produce with artistic attitude. FILTER REGULTOR We produce with artistic attitude. DURY from Germany is expert in fluid control; the products are mainly for control and measurement of various gases, liquid pressure and flow, including

More information

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4 P1H INITURE COINTION UNITS ilter/regulators and lubricators P1H - 1/8, 1/4 Combinations of filterregulators and lubricators can be ordered as pre-assembled units Complete control of filtration, regulation

More information

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 / Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

How to Order. Rc NPT 1/8 1/4 3/8 1/2

How to Order. Rc NPT 1/8 1/4 3/8 1/2 AWM 3 AWD 3 Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 3 E 3 E How to Order Mist Separator Regulator 1 2 Micro Mist Separator Regulator The AWM series is made up

More information

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81) Air bellows, single acting Ø... / inch Suitable for applications on rail vehicels Almost frictionless operation No maintenance or lubrication Weather/corrosion resistant metal parts Approvals for fire

More information

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi).

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi). FR12MD FR38MD Modular filter-regulators, suitable for compressed air FEATURES Filter-regulator for inlet pressure up to 30 bar (435 psi). Inlet and outlet connections 1/2 F and 3/8 F in the body. Outlet

More information

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2 Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).

More information

FR + LUB UNITS. For full details and list of components refer to the sections about filter-regulator and the lubricator.

FR + LUB UNITS. For full details and list of components refer to the sections about filter-regulator and the lubricator. FR + UB For full details and list of components refer to the sections about filter-regulator and the lubricator. FR + UB Syntesi TECHNICA DATA Threaded port Degree of filtration Max. inlet pressure bar

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature

More information

TEST BENCH FOR SAFETY VALVES

TEST BENCH FOR SAFETY VALVES TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of

More information

GENO -Flushing Compressor Product Data Sheet F 02

GENO -Flushing Compressor Product Data Sheet F 02 GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure

More information

Precision Pressure Regulators

Precision Pressure Regulators hapter - Pressure Regulators Pressure range onnection thread Device Page 3 mm, high precision 0.0 2 / 8 bar G 1 8 RI.02 highly sensitive, max. 3 bar supply pressure 0.002 0.12 / 31 bar ¼"NPT R40.03 without

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi).

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi). Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 info@idinsertdeal.com www.idinsertdeal.com FR12MD FR38MD Modular filter-regulators, suitable for compressed air FEATURES Filter-regulator

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX /-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.

More information

Directional valves Pneumatically operated Series CD07. Brochure

Directional valves Pneumatically operated Series CD07. Brochure Series CD07 Brochure 2 Bosch Rexroth AG Pneumatics Series CD07 2/2-way valve, Series CD07 Qn = 1400 l/min pipe connection compressed air connection output: M14x1,5 suitable for ATEX 3 3/2-way valve, Series

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

Genie Supreme TM Model 123HP Installation & Operation Instructions

Genie Supreme TM Model 123HP Installation & Operation Instructions Genie Supreme TM Model 123HP Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales,

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Filter-Regulator-Lubricator

Filter-Regulator-Lubricator Models: 10671-1/2" NPT Filter 10673-1/2" NPT Regulator 10675-1/2" NPT Lubricator 10677-1/2" NPT Filter-Regulator 10679-1/2" NPT Regulator-Lubricator 10681-1/2" NPT Filter-Regulator-Lubricator Parts Page

More information

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet

More information

Dival 500 Pressure Regulators

Dival 500 Pressure Regulators Dival 500 Pressure Regulators Dival 500 Classification and Range of use The DIVAL 500 is a downstream direct-acting pressure regulator with balanced plug, for low, medium and high pressures. Suitable for

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

SG3 Series Regulators - Pressure Reducing

SG3 Series Regulators - Pressure Reducing SG3 Series Regulators - Pressure Reducing DSG333X1 Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-4; ASME B31; ASME BPVC

More information

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series NEWS 66 Components for Pneumatic Automation VALVES & AIR SERVICE UNITS STEEL LINE Series www.pneumaxspa.com Valves General The new Steel line valve series was created and developed specifically for the

More information

Filter-Regulator-Lubricator

Filter-Regulator-Lubricator Filter-Regulator-Lubricator 1/2" NPT Inlet/Outlet Ports PD16.19 July, 2016 Machine Parts & Operating Instructions Save This Document and Educate All Personnel WARNING Always follow the safety instructions

More information

Model Air Caddy Orig TABLE OF CONTENTS

Model Air Caddy Orig TABLE OF CONTENTS 92-0919 Orig. 020201 Model 75-0114 Air Caddy TABLE OF CONTENTS CUSTOMER MESSAGE Inside Front Cover SAFETY PRECAUTIONS 3 GENERAL DESCRIPTION 6 SPECIFICATIONS 7 MAINTENANCE 9 INSTALLATION AND OPERATION 11

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating

More information

Guardian Membrane Separators

Guardian Membrane Separators Guardian Membrane Separators Our Guardian Membrane Separators and Spin Clean filters offer superb protection with easy field maintenance. The Guardian Membranes are ideal for protecting GC s, O 2 Analyzers,

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information