National Marine Manufacturers Association

Size: px
Start display at page:

Download "National Marine Manufacturers Association"

Transcription

1 1. All of the following would be considered as a compliant seacock except a. an in-line ball valve with a lever type handle operating through a 180 arc b. a flanged sea valve which mounts directly to the boat hull structure c. an in-line ball valve supported only by the through-hull fitting d. a flanged sea valve which indicates open or shut 2. M a x i m u m H e e l e d W a t e r l i n e f o r a s a i l b o a t i s a. the level of water on the hull when the hull is inclined to 7 b. the level of water on the hull when the hull is inclined to 28 c. the level of water on the hull when the hull is inclined to the sheer at amidships d. the level of water on the hull when the hull is inclined to the sheer at the transom 3. Expandable type drain plugs can only be used a. if they are designed to allow disassembly b. if they are designed to meet ANSI/UL 1121 c. if the boat is manually propelled d. if the boat meets the flotation requirements of ABYC H-8 4. Attachment of the drain plug body to the hull shall be a. water tight under normal operating conditions b. water tight under any operating conditions c. water tight using a UL Marine sealant d. water tight, showing no leakage after 18 hours of submersion

2 5. A b o a t i n i t s static floating position includes all the following except a. fuel tanks filled to rated capacity b. water tanks filled to their rated capacity c. optional engine(s), battery(s), seats, railings, fishing towers d. permanently installed factory supplied equipment 6. All piping, tubing or hose lines penetrating the hull below the maximum heeled waterline shall be equipped with a seacock except a. boats that comply with the Basic Flotation requirements of ABYC H-8 b. boats that utilize inflation chambers i.e. inflatables or RIBs c. through hulls below the boats static floating position waterline that use reinforced piping or hose d. through hulls above the boats static floating position waterline that use reinforced piping or hose 7. I f a b o a t i s f i t t e d w i t h a d r a i n p l u g a. it shall be readily accessible b. it shall be accessible (allowing the use of hand tools) c. it shall be of metallic construction d. there s no if about it, ALL boats must be fitted with a drain plug 8. Metal through hull fittings on metal hulled boats a. must not be electrically isolated from the hull plating b. must be bonded as per ABYC E-2 c. shall be galvanically compatible with the hull plating d. cannot be used due to corrosion concerns

3 9. You do not have to use a seacock to stop admission of water via through-hull fittings above the maximum heeled waterline if a. the boat is greater than 26 in length b. double hose clamps are used at both ends of the hose c. due to the design of the boat the valves would not be readily accessible d. this standard does not require seacocks above the maximum heeled waterline 10. A properly installed seacock assembly will a. withstand a 500-pound static force applied for 30 seconds b. withstand a 200-pound static force applied for 60 seconds c. withstand a 500-pound static force applied for 30 seconds and will stop at least 50% the ingress of water afterward d. withstand a 200-pound static force applied for 60 seconds and will stop at least 75% the ingress of water afterward 11. I n s t a l l e d d r a i n p l u g s s h a l l b e i n s t a l l e d i n a. what is expected to be the lowest portion of the bilge when the boat is in its static floating position b. what is expected to be the lowest portion of the bilge when the boat is in storage c. what is expected to be the lowest portion of the bilge when the boat is on its trailer d. what is expected to be the lowest portion of the bilge when the boat is underway 12. Tapered, soft-wood drain plugs a. may be used in wooden boats only b. do not have to be water tight c. must be kept dry when not in use d. are non-compliant with this standard and may not be used

4 13. If space constraints prevent the seacock from being directly connected to the through hull fitting a. a flexible hose that is doubled clamped at each end may be used b. changes to the boat design will have to be made c. one non-flexible component may be installed d. one non-flexible component not exceeding 6 in length may be installed 14. A boat is in its static floating position when afloat in calm, fresh water, with fuel tanks filled and a. water tanks are full and waste tanks are empty b. the number of persons posted on the boats capacity label are on board c. all safety gear required by the USCG is properly stowed d. optional T-top or Hardtop is installed 15. B o a t s w i t h u n d e r w a t e r e n g i n e e x h a u s t t h r u - h u l l s a. have automatic shutoffs operated by the engine ignition circuit b. h a v e a n i n d i c a t o r o f w a t e r p a s s i n g t h r o u g h t h e e x h a u s t t e r m i n u s c. must have seacocks fitted to each exhaust terminus d. s h a l l c o m p l y w i t h A B Y C P Other standards are incorporated by reference within H-27. Which of the following is not listed in those references? a. ABYC H-8, Buoyancy in the Event of Swamping b. ABYC E-2, Cathodic Protection c. ABYC H-4, Cockpit Drainage Systems d. ABYC P-1, Installation of Exhaust Systems for Propulsion and Auxiliary Engines.

5 17. I n o r d e r t o c o m p l y w i t h t h i s s t a n d a r d a l l b o a t s m u s t h a v e a r e a d i l y a c c e s s i b l e d r a i n p l u g 18. Seacocks and Thru-hull fittings shall be designed and constructed to meet a. ANSI/UL 1121, Marine Through Hull Fittings and Sea-Valves b. US Coast Guard Code of Federal Regulations 33 CFR c. Independent third party standards such as USMAS d. ANSI/UL 1211, Marine Through Hull Fittings and Sea-Valves 19. A through-hull discharge fitting of a bilge pump that is above the waterline but below the maximum heeled waterline of a sailboat must be fitted with a seacock (assume boat does not meet any exceptions to H ). 20. F o r t h e p u r p o s e s o f N M M A c e r t i f i c a t i o n t h i s s t a n d a r d, H i s o n l y a p p l i e d t o b o a t s o v e r 2 6 i n t h e Y a c h t P r o g r a m?

MSC Guidelines for Engine Cooling Systems

MSC Guidelines for Engine Cooling Systems S. T. Brady, CDR, Chief, Engineering Division References: Contact Information: a. 46 CFR 56.60, 56.50-95 & 56.50-96 (Subchapter F) b. 46 CFR 77.03-1 (Subchapter H) c. 46 CFR 90.20 & 46 CFR 96.03 (Subchapter

More information

MSC Guidelines for Vents, Fills and Sounds

MSC Guidelines for Vents, Fills and Sounds S. J. Kelly, CDR, Chief of Engineering Division References: a. 46 CFR 56.50-85 & 56.50-90 (Subchapter F) b. 46 CFR 32.55, 36.20-1 & 38.20 (Subchapter D) c. 46 CFR 119.445 & 119.450 (Subchapter K) d. 46

More information

Modified Level Flotation

Modified Level Flotation Modified Level Flotation Applies to: Mono-hull Boats (not catamarans, trimarans, or pontoon boats): Mono-hull means that if you can draw a continuous line around the hull at the waterline when the boat

More information

Technical Documentation

Technical Documentation Recreational Craft Directive RYA Compliance Guide Appendix 7 Technical Documentation General The Technical Documentation is the key documentation required by the Directive. If challenged the builder must

More information

Flotation Introduction

Flotation Introduction Flotation Introduction Why are small boats required to have flotation, and why are there different requirements? Back in the 1950's and 60's the old Boating Industry Association (now NMMA) and the Yacht

More information

2. The reference depth is an important measurement for basic flotation testing?

2. The reference depth is an important measurement for basic flotation testing? 1. The definition of the term Deadweight is a. The maximum weight capacity minus the persons capacity for outboards b. The maximum weight capacity minus the persons capacity for inboards, sterndrives,

More information

MSC Guidelines for Bilge and Ballast Systems

MSC Guidelines for Bilge and Ballast Systems S. T. Brady, CDR, Chief, Engineering Division References: a. Except as provided below, all vessels need to meet CFR 56.50-50 (bilge and ballast piping) and 56.50-55 (bilge pumps). b. Tankships (Subchapter

More information

part ten hire boats & safety features

part ten hire boats & safety features part ten hire boats & safety features Taughtline Hitch This Part of the BSS Standards addresses such risks as falling overboard, sinking and personal injury. The Standards and associated Check List items

More information

MUD 1. Vent check valves. Instruction and maintenance manual.

MUD 1. Vent check valves. Instruction and maintenance manual. MUD 1 Vent check valves Instruction and maintenance manual. Version: 04-02-2011. 2 List of Contents 1. INTRODUCTION 3 1.1 The Problem... 3 1.2 The Solution... 3 2. RULES AND REGULATIONS 3 2.1 General requirements....

More information

a. 27 inches or 0.69 m above the surface of the compressed seat;

a. 27 inches or 0.69 m above the surface of the compressed seat; 1. The purpose of the H-1 standard is to, a. Insure operator has appropriate visibility under all conditions of heel and trim b. Insure visibility during towing operations such as waterskiing & wake boarding

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

[ ] 10 YEAR HULL WARRANTY [ ] GEL COAT: [ ] RESIN: [ ] FIBERGLASS [ ] VACUUM BAGGING:

[ ] 10 YEAR HULL WARRANTY [ ] GEL COAT: [ ] RESIN: [ ] FIBERGLASS [ ] VACUUM BAGGING: Progression 22 This list is provided to help you to evaluate the many advantages that come STANDARD with a PROGRESSION 22. As you compare Progression s many superior features to the competition, it will

More information

National Marine Manufacturers Association Product Compliance Specialist Examination Ladders, Handholds & Rails (2015 MY) ABYC H-41 (09)

National Marine Manufacturers Association Product Compliance Specialist Examination Ladders, Handholds & Rails (2015 MY) ABYC H-41 (09) 1. Which of the following are within the scope of H-41: a. Manual propelled boats b. Pontoon boats c. Canoes & kayaks d. All of the above 2. Static Float Position is determined by: a. including permanently

More information

1. For the purposes of this standard, the maximum weight capacity of a boat is:

1. For the purposes of this standard, the maximum weight capacity of a boat is: 1. For the purposes of this standard, the maximum weight capacity of a boat is: a. The maximum load the boat may carry plus 32 divided by 141 b. The load displayed on the capacity label c. The load displayed

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

3604 ValhannaCatalina 37

3604 ValhannaCatalina 37 3604 ValhannaCatalina 37 Starting DC Main Breaker House Locker Settee Windless Breaker Nav Table Aft Cabin V Berth I I Head Intake T T Head Sink Drain (Head) Shower Drain Settee Sink Drain (Galley) T Galley

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 5 Powering

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 5 Powering ICOMIA Global Conformity Guideline for ISO and ABYC Standards sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 5 Powering 1. PURPOSE These documents were created by

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

3405 Vested Interest Hunter 34 Y Valve

3405 Vested Interest Hunter 34 Y Valve 3405 Vested Interest Hunter 34 Y Valve Sink Drain V Berth Settee USCG No. Nav Head Head Intake o Holding ank o Overboard I I Aft Cabin Engine Intake Settee Sink Drain Galley Legend Notes Engine Oil Dipstick

More information

S/Y MORSKI ZEKAN TECHNICAL INFORMATION

S/Y MORSKI ZEKAN TECHNICAL INFORMATION S/Y MORSKI ZEKAN TECHNICAL INFORMATION Cabins: 3 Toilets: 1 Max. Persons: 8 (6+2) LOA: 11,35 m Beam: 3,80 m Draft: 1,95 m Engine: Volvo 28HP Water tanks: 360 L Fuel tank: 150 L Anchor windlass Speed and

More information

PART 3 HULL INTEGRITY AND ARRANGEMENT

PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT SECTION SUBJECT 3.1 General 3.2 Doors, hatchways and covers 3.3 Air pipes 3.4 Ventilators 3.5 Side scuttles (portholes) and

More information

Progression 24LD Stern Drive

Progression 24LD Stern Drive Progression 24LD Stern Drive This list is provided to help you to evaluate the many advantages that come STANDARD with a PROGRESSION 24LD. As you compare Progression s many superior features to the competition,

More information

4301 Whale Song Jeanneau 43

4301 Whale Song Jeanneau 43 4301 Whale Song Jeanneau 43 Settee Galley Sink Drain Unused Engine Intake V Berth House Bank Common Shower Drain Head I I Sink Drain Bilge Pump USCG NO. Fuel ank Head Intake Head Engine Bank Aft Cabin

More information

RULES OF TENNESSEE WILDLIFE RESOURCES AGENCY BOATING AND LAW ENFORCEMENT

RULES OF TENNESSEE WILDLIFE RESOURCES AGENCY BOATING AND LAW ENFORCEMENT RULES OF TENNESSEE WILDLIFE RESOURCES AGENCY BOATING AND LAW ENFORCEMENT CHAPTER 1660-02-03 RULES AND REGULATIONS GOVERNING EQUIPMENT REQUIRED ON VESSELS AND NAVIGATION RULES TABLE OF CONTENTS 1660-02-03-.01

More information

INSTALLATION OPERATION MAINTENANCE

INSTALLATION OPERATION MAINTENANCE Bermad Electrically Controlled On-Off Deluge Valve Model: 400E-3D INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working

More information

JAMES CROSS, Certified Marine Surveyor. June 12, Jupiter 38 Forward Seating. Dear Mr. Buyer,

JAMES CROSS, Certified Marine Surveyor. June 12, Jupiter 38 Forward Seating. Dear Mr. Buyer, JAMES CROSS, Certified Marine Surveyor 19 Nooseneck Hill Rd., West Greenwich, RI 02817 Phone (401) 397-5040 Member Association of Certified Marine Surveyors//ACMS-USA.COM Check us out on the web at www.jimcross.net

More information

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems INTERNATIONAL STANDARD ISO 10239 Second edition 2008-02-15 Small craft Liquefied petroleum gas (LPG) systems Petits navires Installations alimentées en gaz de pétrole liquéfiés (GPL) Reference number ISO

More information

One World 40 Lagoon Catamaran Reference Notes. Index

One World 40 Lagoon Catamaran Reference Notes. Index One World 40 Lagoon Catamaran Reference Notes Index These notes are intended to be used as reminders only; not as a substitute for proper training, boat check-out, and operating manual review Verify locations,

More information

Marelon - Marine Grade Plumbing Systems

Marelon - Marine Grade Plumbing Systems TECH TIPS Marelon - Marine Grade Plumbing Systems Non-Corrosive Non-Conductive Fire Resistant Impact Resistant (exceeds U.L., ABYC and ISO standards) Operating temperature range -40 to 200 F U.V. Stabilized

More information

AUSTRALIAN BUILDERS PLATE Frequently Asked Questions General Public

AUSTRALIAN BUILDERS PLATE Frequently Asked Questions General Public AUSTRALIAN BUILDERS PLATE Frequently Asked Questions General Public The ABP and the law 1. Is the ABP required by law? All Australian States apply the National Standard for the Australian Builders Plate

More information

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate

More information

AS (Incorporating Amendment Nos 1 and 2) AS Australian Standard. Small craft. Part 1: General requirements for power boats

AS (Incorporating Amendment Nos 1 and 2) AS Australian Standard. Small craft. Part 1: General requirements for power boats AS 1799.1 2009 (Incorporating Amendment Nos 1 and 2) AS 1799.1 2009 Australian Standard Small craft Part 1: General requirements for power boats This Australian Standard was prepared by Committee CS-001,

More information

Mount the actuator in the bracket provided and install a 24-foot EFTC cable to the actuator.

Mount the actuator in the bracket provided and install a 24-foot EFTC cable to the actuator. . Mount the actuator in the bracket provided and install a 4-foot EFTC cable to the actuator. Route the cable through left stanchions,, and 4. Be sure that the cable does not contact any spring or push

More information

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE Page 1 of 8 Compiled by Chief Examiner Approved by Qualifications Committee: 27 September 2013 OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE Page 2 of 8 KNOWLEDGE, UNDERSTANDING

More information

Bermad Model:

Bermad Model: Bermad Model: 405-02 Manually Operated Hydraulic Valve INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around

More information

PART 3 HULL INTEGRITY AND ARRANGEMENT

PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT SECTION SUBJECT 3.1 Doors, hatchways, and coamings 3.2 Air pipes 3.3 Ventilators 3.4 Portlights 3.5 Skylights 3.6 Windows 3.7

More information

Inspection Card for Race Category 3 (with liferaft) Monohulls

Inspection Card for Race Category 3 (with liferaft) Monohulls World Sailing Offshore Special Regulations Inspection Card for Race Category 3 (with liferaft) Monohulls PERSON IN CHRGE (See Racing Rules of Sailing 46): please prepare the boat, initial above the underline

More information

Definitions 13 FREE SURFACE EFFECT

Definitions 13 FREE SURFACE EFFECT Definitions 13 FREE SURFACE EFFECT When a vessel with a full tank is heeled, the liquid within the tank acts like a solid mass. Its centre of gravity, being the centre of its volume, remains constant and

More information

Chapter 2. Before You Get Underway. Copyright Coast Guard Auxiliary Association, Inc.

Chapter 2. Before You Get Underway. Copyright Coast Guard Auxiliary Association, Inc. Chapter 2 Before You Get Underway 1 We ll Discuss: 1 Capacity 2 Float Plan 3 Pre-Departure Checks 4 Trailering & Fueling - Safety 5 Launching and Retrieving 6 Boat Maintenance 7 Boating Accessories 2 Capacity

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

COMPRESSED AIR DISTRIBUTION SYSTEMS

COMPRESSED AIR DISTRIBUTION SYSTEMS Series COMPRESSED AIR DISTRIBUTION SYSTEMS 18 DESIGNING AN EFFICIENT COMPRESSED AIR DISTRIBUTION The main source of inefficiencies and problems affecting compressed air distribution systems is often the

More information

Installation and service should be performed by a qualified service professional.

Installation and service should be performed by a qualified service professional. Damage to your lift or vessel can result from improper initial setup of the system. Consult a HydroHoist Certified Installer for initial setup and support Installation and service should be performed by

More information

Livewell/Baitwell Pumps. Livewell/Aerator

Livewell/Baitwell Pumps. Livewell/Aerator Livewell/Baitwell Pumps 03 Livewell/Baitwell Pumps Livewell/Aerator 049 050 03 Livewell / Baitwell Pumps selection GUIDE Livewell / Baitwell Pumps Tournament Series Bronze Base Fitting Discharge Outlet

More information

Surface Guide to Damage Control National Response Directorate

Surface Guide to Damage Control National Response Directorate Surface Guide to Damage Control National Response Directorate Disclaimer This guide is not a substitute for applicable policy The best practices presented in this guide should augment and support the safe

More information

Transom. Stern. Starboard side. Stem between planing and displacement hulls. Sample. page

Transom. Stern. Starboard side. Stem between planing and displacement hulls. Sample. page Chapter 1 Review questions 1. Label the illustration of the boat opposite using the list of terms provided. Bow, stern, port side, all-round light, stem, transom, deck, portside, starboard side, coaming,

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

LOGO TO COME PLEASE PROVIDE. Ballast & Tower. Operator s Manual

LOGO TO COME PLEASE PROVIDE. Ballast & Tower. Operator s Manual LOGO TO COME PLEASE PROVIDE Ballast & Tower Operator s Manual INTRODUCTION INTRODUCTION...2 SAFETY...3 Safety Warnings...3 Medical Emergency...3 Reporting Accidents...3 Boat Capacity Chart...4 TOWER...5

More information

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 3501 GENERAL 3501.1 Scope. The storage and use of flammable gases shall be in accordance with this chapter. Compressed gases shall also

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Skum Bladder Tank Type Vertical. Table of Contents Page General Description 2 1. Installation 1.1 Safety 2 1.2 Transporting 2 1.3 Inspection 2 1.4 Filling Instruction 3-7

More information

MSC Guidelines for Independent Fuel Tanks

MSC Guidelines for Independent Fuel Tanks References: Contact Information a. 46 CFR 58.50 (Independent Fuel Tanks) b. 46 CFR 119.440 (Independent Fuel Tanks) c. 46 CFR 182.440 (Independent Fuel Tanks) C. J. Robuck, LCDR, Chief, Engineering Division

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

4206 Windsong Catalina 42

4206 Windsong Catalina 42 Forward Head Sink Drain USCG NO. Cabinets Nav AC/DC Panel Settee Emergency iller Head Head Sink Outlet Head Intake Aft Cabin Head Head Intake Engine Intake Pullman Berth R Laz Shower Drain Macerator Outlet

More information

DURAS INFLATABLE BOAT OWNER'S MANUAL

DURAS INFLATABLE BOAT OWNER'S MANUAL DURAS INFLATABLE BOAT OWNER'S MANUAL Table of Contents About your new Duras Inflatable Boat Page 1 Assembly Instruction Page 3 Motor Installation Page 5 Capacities Page 5 Troubleshooting Page 6 Using

More information

ABYC A-1 MARINE LIQUEFIED PETROLEUM GAS (LPG) SYSTEMS Table of Contents 1.1 PURPOSE SCOPE REFERENCED ORGANIZATIONS...

ABYC A-1 MARINE LIQUEFIED PETROLEUM GAS (LPG) SYSTEMS Table of Contents 1.1 PURPOSE SCOPE REFERENCED ORGANIZATIONS... ABYC A-1 MARINE LIQUEFIED PETROLEUM GAS (LPG) SYSTEMS Table of Contents 1.1 PURPOSE... 2 1.2 SCOPE...2 1.3 REFERENCED ORGANIZATIONS... 2 1.4 DEFINITIONS - For the purposes of this standard, the following

More information

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 2 of 52 A-ARM, FLOOR PANEL, AND BUMPER

More information

Boating Tip #47: Safety Gear & Required Equipment

Boating Tip #47: Safety Gear & Required Equipment Boating Tip #47: Safety Gear & Required Equipment The U.S. Coat Guard requires that recreational vessels carry specific safety equipment while underway. The safety gear must be in good condition and readily

More information

400/488 Rotating Davit Installation Instructions

400/488 Rotating Davit Installation Instructions 400/488 Rotating Davit Installation Instructions These instructions were written with the owner in mind. If you are the installer make sure these instructions are passed along to the owner of the boat.

More information

4207 M Catalina 42. Nav. Head. Aft Cabin. V Berth. Head. Laz. Galley. Settee. Legend. Notes USCG NO. First Aid Kit. Head. AC/DC Panel. Sink.

4207 M Catalina 42. Nav. Head. Aft Cabin. V Berth. Head. Laz. Galley. Settee. Legend. Notes USCG NO. First Aid Kit. Head. AC/DC Panel. Sink. Nav ool for Emergency iller Settee AC/DC Panel USCG NO. First Aid Kit Head Sink Head Aft Cabin V Berth Head I I Watermaker AC Supply Head Intake Raw H2O Engine Generater E Legend Engine Oil Dipstick Emergency

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Dry 132a. October 1, 2008 October 1, 2008 Dry 132a 1. Description Viking High Pressure (HP) Dry Systems utilize a Viking Model E or Model F Deluge Valve to control the water supply to system piping equipped with closed sprinklers.

More information

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

part seven lpg installations

part seven lpg installations part seven lpg installations Reef Knot LPG (Liquefied Petroleum Gas) is kept under pressure as a liquid and when released becomes a highly flammable gas that is much heavier than air. The aim of this part

More information

ISAF OFFSHORE SPECIAL REGULATIONS Appendix J

ISAF OFFSHORE SPECIAL REGULATIONS Appendix J Page - 95 - APPENDIX J CATEGORY 5 SPECIAL REGULATIONS for inshore races Category 5 Special Regulations are intended for use in short races, close to shore in relatively warm and protected waters where

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 6185-4 First edition 2011-07-01 Inflatable boats Part 4: Boats with a hull length of between 8 m and 24 m with a motor power rating of 15 kw and greater Bateaux pneumatiques

More information

MSC Guidelines for Compressed Air Systems

MSC Guidelines for Compressed Air Systems Procedure Number: E1-04 Revision Date: 12/16/2013 References: a. 46 CFR 54 Pressure Vessels (Subchapter F) P. W. Gooding, CDR, Chief, Engineering Division b. 46 CFR 56 Piping Systems & Appurtenances (Subchapter

More information

TRADESMAN DRAINLAYER

TRADESMAN DRAINLAYER No. 9197 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced

More information

Merlin-615 MKI, Waterjet

Merlin-615 MKI, Waterjet Merlin-615 MKI, Waterjet Norsafe Project No.: 9808 Norsafe Doc. No.: TSB-0397 Rev. Date: 27.04.2017 Rev. No: 0 Norsafe AS P.O. Box 115 N-4852 Faervik, Norway Tel: +47 37 05 85 00 Fax: +47 37 05 85 01 E-mail:

More information

BY HYDROHOIST BOATLIFTS

BY HYDROHOIST BOATLIFTS BY HYDROHOIST BOATLIFTS OWNER S MANUAL US PATENT # 6,422,167 B1 REVISED: June 21st 2018 800.825.3379 BOATLIFT.COM Thank You We would like to a moment to thank you for purchasing a HarborHoist TM G1.5 lift.

More information

03 Vessel Fitness and Safety

03 Vessel Fitness and Safety 03 Vessel Fitness and Safety Competence (Skills) Knowledge, Understanding and Proficiency Level Required Vessel Terminology and Characteristics Vessel hull types and configurations Members must know the

More information

ON-DECK TRIP: Charter Boat Check-Out/Check-In Form

ON-DECK TRIP: Charter Boat Check-Out/Check-In Form Charter Boat Check-Out/Check-In Form TRIP: Skipper: Phone: Boat Type & Size: Boat Name: Draft: Beam: Mast Height: Water: Cap. Gal. in tank(s) Waste: Cap. Gal in tank(s) Fuel: Cap. Gal THIS FORM IS FOR

More information

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1 November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:

More information

What hull material types will the system work on? Do I still need an antifoul paint?

What hull material types will the system work on? Do I still need an antifoul paint? 1. The Hull What hull material types will the system work on? The system is effective on all GRP (Glass Reinforced Plastic), STEEL and ALUMINIUM hulls up to thickness of 70mm. Unfortunately the system

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

Draft. Not yet Approved

Draft. Not yet Approved 201178 Part 12.5.20 Recommended Safety Instructions for LP-Gas Winter Switch Protection Devices Revised 201178 (6 Pages) A. Purpose 1. This Manual Part recommends instructions for LP-Gas systems servicing

More information

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Table 1 - Specifications Page 1 of 6 1. DESCRIPTION Model A-3 Pilot Operated Pressure Control Valves are factory assembled units. Each unit consists of a Model H-2 Halar coated Flow Control Valve, a Speed Control Valve, a Model

More information

Combination Air Valve

Combination Air Valve Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials

More information

GRAND Silver Line S250, S275, S300, S330. Rigid Inflatable Boat SILVER LINE. Models: S250, S275, S300, S330 S300S, S330S.

GRAND Silver Line S250, S275, S300, S330. Rigid Inflatable Boat SILVER LINE. Models: S250, S275, S300, S330 S300S, S330S. Rigid Inflatable Boat SILVER LINE Models: S250, S275, S300, S330 S300S, S330S User`s Manual The rigid inflatable motor boat of the "SILVER LINE" series relates to the category of pleasure boats and is

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

LAGOON BOAT CLUB. DECLARATION OF COMPLIANCE AND SAFETY EQUIPMENT CHECKLIST 2016 and 2017

LAGOON BOAT CLUB. DECLARATION OF COMPLIANCE AND SAFETY EQUIPMENT CHECKLIST 2016 and 2017 LAGOON BOAT CLUB DECLARATION OF COPLIANCE AND SAFETY EQUIPENT CHECKLIST 2016 and 2017 Submitted to the Lagoon Boat Club Inc. For the year November 2016 to October 2017 Boat Name : Sail Number : Date :

More information

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE. Wet pipe low flow manifold system June 1, 2008 Foam 15a 1. Description Multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various riser types and sizes that are to supply foam solution

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 31a 1. Description With Multiple Pilot Pressure Regulating Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple pilot pressure regulating foam risers can be supplied from

More information

MSC Guidelines for Sanitary & Sewage Systems

MSC Guidelines for Sanitary & Sewage Systems S. J. Kelly, CDR, Chief of Engineering Division References: Contact Information: a. Title 33 CFR 159; Marine Sanitation Devices (All Vessels) b. Title 46 CFR 56.50-1 & 56.50-95 (Subchapter F) c. Title

More information

U.S. POWER SQUADRONS QUALIFICATION EXAMINATION FOR VESSEL EXAMINER. 1. Check the subject of this examination to insure it is the one requested.

U.S. POWER SQUADRONS QUALIFICATION EXAMINATION FOR VESSEL EXAMINER. 1. Check the subject of this examination to insure it is the one requested. Test Edition: A Test Number: 99 Course Code: VSC Rev. Date: 12/14 Revised Manual U.S. POWER SQUADRONS QUALIFICATION EXAMINATION FOR VESSEL EXAMINER 1. Check the subject of this examination to insure it

More information

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke : Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1 by HAWE Hydraulik SE. The reproduction and distribution

More information

Miss Joy Boat Manual

Miss Joy Boat Manual Miss Joy Boat Manual BOAT CODE H33 SLIP F97 MAXIMUM CAPACITY: 8 PASSENGERS Violation Will Result In Suspension of Members Certification and Charter Privileges 111917 24707 Dana Drive, Dana Point, CA 92629

More information

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail

More information

At this time of year,

At this time of year, At this time of year, we hope bobtails are scurrying about to meet demand. As you do so, there are a few things your drivers should be doing to make sure that they and your customers are kept safe. A safe

More information

KC Series Gas Components and Supply Design Guide

KC Series Gas Components and Supply Design Guide Technical Bulletin KC Series Gas Components and Supply Design Guide GF-1030 General AERCO KC Series gas fired potable water heaters and boilers are modulating input devices that require an adequate volume

More information