Cartridge Valves Technical Information Motor Mount HICs Quick Reference

Size: px
Start display at page:

Download "Cartridge Valves Technical Information Motor Mount HICs Quick Reference"

Transcription

1 Quick Reference Symbol Description Order No. Page DH/DS MOUNT OMP/OMR/OMH MOUNT OMS MOUNT OMT MOUNT mount HIC Test lock P14 Symbol Description Model No. Page Dual counterbalance valve DH MM-DH--DC1-HV DS MM-DS--DC1-HV OMP/OMR MM-OMP/OMR--DC1-HV OMH MM-OMH--DCP OMS MM-OMS--DCP OMT MM-OMT--DCP Quick reference Symbol Description Model No. Page Single counterbalance valve ( port) DH MM-DH--C1-HV DS MM-DS--C1-HV OMP/OMR MM-OMP/OMR--C1-HV 15.3 OMH MM-OMH--CP OMS MM-OMS--CP OMT MM-OMT--CP P14 Symbol Description Model No. Page Single counterbalance valve ( port) DH MM-DH--C1-HV DS MM-DS--C1-HV OMP/OMR MM-OMP/OMR--C1-HV OMH MM-OMH--CP OMS MM-OMS--CP OMT MM-OMT--CP P14 Symbol Description Model No. Page Dual counterbalance valve with shuttle DH MM-DH-LS-DC1-HV DS MM-DS-LS-DC1-HV 15.4 OMP/OMR MM-OMP/OMR-LS-DC1-HV OMH MM-OMH-LS-DCP OMS MM-OMS-LS-DCP OMT MM-OMT-LS-DCP S P14 52L588 Rev D November

2 Quick Reference Symbol Description Model No. Page Single counterbalance valve ( port) DH MM-DH-LS-C1-HV with shuttle DS MM-DS-LS-C1-HV OMP/OMR MM-OMP/OMR-LS-C1-HV OMH MM-OMH-LS-CP OMS MM-OMS-LS-CP OMT MM-OMT-LS-CP S P14 Quick reference Symbol Description Model No. Page Single counterbalance valve ( port) DH MM-DH-LS-C1-HV with shuttle DS MM-DS-LS-C1-HV OMP/OMR MM-OMP/OMR-LS-C1-HV OMH MM-OMH-LS-CP OMS MM-OMS-LS-CP OMT MM-OMT-LS-CP S Symbol Description Model No. Page Dual cross-port relief valve DH MM-DH--DVME DS MM-DS--DVME OMP/OMR MM-OMP/OMR--DVME Symbol Description Model No. Page Dual cross-port relief valve OMH MM-OMH--DCP OMS MM-OMS--DCP OMT MM-OMT--DCP L588 Rev D November 21

3 Quick Reference Symbol Description Model No. Page Single cross-port relief valve ( port) DH MM-DH--VME DS MM-DS--VME OMP/OMR MM-OMP/OMR--VME P14 Symbol Description Model No. Page Single cross-port relief valve ( port) OMH MM-OMH--CP OMS MM-OMS--CP OMT MM-OMT--CP P14 Quick reference Symbol Description Model No. Page Single cross-port relief valve ( port) DH MM-DH--VME DS MM-DS--VME OMP/OMR MM-OMP/OMR--VME P14 Symbol Description Model No. Page Single cross-port relief valve ( port) OMH MM-OMH--CP OMS MM-OMS--CP OMT MM-OMT--CP P14 52L588 Rev D November

4 Quick Reference Symbol Description Model No. Page Dual cross-port relief valve with shuttle DH MM-DH-LS-DVME DS MM-DS-LS-DVME OMP/OMR MM-OMP/OMR-LS-DVME S Quick reference Symbol Description Model No. Page Dual cross-port relief valve with shuttle OMH MM-OMH-LS-DCP OMS MM-OMS-LS-DCP OMT MM-OMT-LS-DCP S Symbol Description Model No. Page Single cross-port relief valve ( port) DH MM-DH-LS-VME with shuttle DS MM-DS-LS-VME OMP/OMR MM-OMP/OMR-LS-VME S P14 Symbol Description Model No. Page Single cross-port relief valve ( port) OMH MM-OMH-LS-CP with shuttle OMS MM-OMS-LS-CP OMT MM-OMT-LS-CP S P L588 Rev D November 21

5 Quick Reference Symbol Description Model No. Page Single cross-port relief valve ( port) DH MM-DH-LS-VME with shuttle DS MM-DS-LS-VME OMP/OMR MM-OMP/OMR-LS-VME S P14 Symbol Description Model No. Page Single cross-port relief valve ( port) OMH MM-OMH-LS-CP with shuttle OMS MM-OMS-LS-CP OMT MM-OMT-LS-CP S P14 Quick reference Symbol Description Model No. Page ypass solenoid with drain DH MM-DH--SVP1-NCR DS MM-DS--SVP1-NCR OMP/OMR 1 2 MM-OMP/OMR--SVP1-NCR OMH MM-OMH--SVP1-NCR OMS MM-OMS--SVP1-NCR OMS MM-OMT--CP D Symbol Description Model No. Page Dual shock valve with anticavitation DH MM-DH--DPVLP 15.1 DS MM-DS--DPVLP DS MM-OMP/OMR--DPVLP OMH MM-OMH--DPVLP OMS MM-OMS--DPVLP OMT MM-OMT--DPVLP D P14 52L588 Rev D November

6 pplication notes OVERVIEW This family of motor mount HICs (Hydraulic Integrated Circuits) complements Sauer- Danfoss orbital motors also know as Low Speed, High Torque (LSHT) motors. These HICs perform several complementary functions common in LSHT motor applications. mount HIC family pplication notes FUNCTIONS There are four basic types of HIC functions, or schemes, with additional functions available: Counterbalance (or overcenter) - Dual or single valve on or port - With or without brake shuttle Cross-port relief - Dual or single valve on or port - With or without brake shuttle ypass solenoid - With drain port Dual shock valve with anti-cavitation checks - Uses PVLP (shock valve from PVG line) - Dual only - Ductile iron manifold only DVNTGES There are advantages to using Comatrol motor mount HICs: Pre-packaged designs, specifically for SD motors - Pre-work is done to ensure proper assembly and mounting to motor System plumbing and packaging efficiencies - Reduction in fittings, tubing, and/or hoses - Reduction in assembly time HICs have been pre-tested to NFP test standards 15.6 Off-the-shelf solution of common valve functions applied with orbital motors 52L588 Rev D November 21

7 pplication notes ORITL MOTORS There are seven specific Sauer-Danfoss orbital motor types in this program. The table below highlights the motors and their basic technical information. For more information refer to the technical information manual number in the table. HICs fit only the porting configuration shown. Sauer-Danfoss orbital motors compatible with HICs type DH DS OMP OMR OMH OMS OMT Units Displacement range Max pressure drop* [continuous] Max pressure drop* [intermittent] Max flow* [continuous] Max flow* [intermittent] US in3 18 psi 24 psi 15.9 US gal/min 19.8 US gal/min Metric cm3 124 bar 166 bar 6 l/min 75 l/min US in3 2 psi 25 psi 15.9 US gal/min 19.8 US gal/min Metric cm3 138 bar 172 bar 6 75 l/min US in US gal/min 19.8 US gal/min Metric cm3 14 bar 175 bar 6 l/min. 75 l/min US in3 254 psi 29 psi 15.9 US gal/min 19.8 US gal/min Metric cm3 175 bar 2 bar 6 l/min. 75 l/min US in3 254 psi 29 psi 19.8 US gal/min 23.8 US gal/min Metric cm3 175 bar 2 bar 75 l/min. 9 l/min. US in3 35 psi 399 psi 19.8 US gal/min 23.8 US gal/min Metric cm3 21 bar 275 bar 75 l/min. 9 l/min. US in3 29 psi 348 psi 33. US gal/min 39.6 US gal/min Metric cm3 2 bar 24 bar 125 l/min. 15 l/min. Port style for HIC mount Manifold G 1/2 (SP) G 1/2 (SP) G 3/4 (SP) * Pressures and flows are displacement and shaft size dependent. Refer to motor catalog for more specific motor technical details. Technical Information 52L439 [DH and DS Orbital s] 52L262 [OMP, OMR, OMH and OMEW Orbital s] 52L47 [OMS, OMT and OMV Orbital s] pplication notes rotation For the motor mount HIC program, the port designations are illustrated here. With the shaft facing you, is the port on the right, while is the port on the left. rotation Order code The order code is easy to understand. Each code starts with MM for Mount. The second field represents motor type (DH, DS, OMP/OMR, OMH, OMS, or OMT). The third field represents secondary valve ( for none, LS for shuttle). The fourth field gives the primary valve position (D for dual, port, or port) followed by the cartridge used (C1-HV, CP441-1, VME-6, CP211-1, SVP1- NCR, CP52-3 or PVLP). The remainder of the code details options specific to that cartridge, including port style on the HIC. See each individual valve in this section for a detailed breakdown of the available options. Sample order code MM-DH--DC1-HV-1-C-1-E-1--1S mount code =Novalve Dual counterbalance valve Type HV=Hydraulic Vent 52L588 Rev D November 21 Forpilot ratio (3:1) 1=35-11 bar[ psi] 2=6-15 bar[ psi] 3 = 8-23 bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar[ psi] 2 = bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C(1:1) 1=11-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S=l,#1SE 4 =l, 1/2 SP =una-n sealkit Cracking pressure(bar) Example: 1=1bar[145 psi] See C1-HVfor std. settings djust type E=Externaladjustment F =Tamper resistant Check crack pressure P =1bar (14.5 psi) 15.7

8 pplication notes ORITL MOTORS (continued) Important notes s are sold separately from HICs. - Contact your Sauer-Danfoss representative to order motors. - Refer to the motor technical information manual for detailed motor information. Mounting bolts and O-rings are included with the purchase of the HIC. - The service mount kit allows ordering of just bolts and O-rings. - ll O-rings are viton. pplication notes ll HICs in this program are aluminum, except the dual shock valve HIC. - Dual shock valve housing is ductile iron. - For ductile iron on any other HIC, please contact your Comatrol representative. OMP/OMR and OMH use the same mount, but OMH has higher flow capability. - The OMH uses different cartridges to accommodate the higher flow. DH and DS use the same mount, but DS requires an additional subplate to clear the motor housing. - This subplate is included with the purchase of the HIC. - The subplate is also included in the service mount kit for DS HICs. using dual valves have both valves set identically at the factory. Testing - test block is available for HIC testing and adjustment of pressure settings. - The test block order number is For further details, refer to the ccessories section of this catalog. Test block schematic DH/DS MOUNT OMP/OMR/OMH MOUNT OMS MOUNT OMT MOUNT P14 778E L588 Rev D November 21

9 pplication notes COUNTERLNCE VLVES Counterbalance valves prevent motors from drifting excessively due to control valve leakage. They can hold the load in the event of hose/tube failure, or limit overrun when a load is in a lowering or runaway mode (vehicle going downhill). They provide a smooth, cushioned stop when the control valve is suddenly closed. Dual counterbalance valve P S With Shuttle Without Shuttle Counterbalance valves have a pilot ratio of 3.:1, 4.5:1, or 1.:1. Typical pilot ratio for motor applications is 1.:1 n optional shuttle valve is available for functions such as load sensing feedback, operating an unloading valve, or releasing a brake. The shuttle connects the highest pressure port ( or ) to the S port. Configurations are available with dual counterbalance valves, or single valve on or port. Typical counterbalance applications include swing drives, winch drives, and vehicle propulsion. For more information about counterbalance valves, see Counterbalance valves, section 9 of this catalog. pplication notes Dual counterbalance valve F F L588 Rev D November

10 pplication notes COUNTERLNCE VLVES (continued) Sample system circuits with dual counterbalance valve typical rotary circuit application for a counterbalance valve contains a pump, directional control valve, system relief valve, and motor. Without a counterbalance valve there is no back pressure to hold the load on the motor, or to prevent free rotation when the control valve shifts to the neutral position. dditionally nothing prevents motor rotation in the event of hydraulic line failure. pplication notes counterbalance valve controls motion. It also provides protection against hose or tube failure. In this circuit, a dual counterbalance HIC is mounted to a standard motor, providing functionality in both directions. Moving the directional control valve to the left causes the motor to rotate in one direction. The motor rotates the load with free flow going through the check valve portion of the counterbalance valve, while piloting open the opposite counterbalance valve to allow flow to discharge from the motor. Dual counterbalance valve When the directional control valve is centered, the counterbalance valve prevents leakage and locks the load in position. Moving the directional control valve to the right sends flow to rotate the motor in the opposite direction. If the load causes the motor to overrun the pump, pilot pressure to the downstream counterbalance valve decreases and the valve modulates to match the motor speed to the pump flow. P Typical application of dual counterbalance valve in a motor circuit L588 Rev D November 21

11 pplication notes COUNTERLNCE VLVES (continued) with dual counterbalance valve and shuttle operating a brake and unloading valve dding a load sense, or brake shuttle valve allows further functionality. In this circuit, an integral brake and an unloading valve (logic element), are added. The shuttle valve senses the higher pressure work port and provides pressure to release the brake when the system pressure exceeds the minimum brake release pressure. When the directional control valve shifts in either direction, pressure builds in the circuit to release the brake and allows the motor to rotate. s shown in the diagram, an orifice provides a slight delay in timing the brake release. When the directional control valve is centered, the brake re-engages. dditionally, the LS pressure signal pilots an unloading valve. When the directional control valve is centered, pressure builds at the outlet of the gear pump and opens the unloading valve, allowing the pump flow to bypass the circuit and exhaust into the reservoir. When the directional control valve shifts in either direction, the unloading valve is piloted to stay in the closed position, thus allowing pump flow to enter the working circuit. Similarly, this LS pressure could communicate flow demand to a load sensing open circuit piston pump. Dual counterbalance with shuttle S pplication notes P14 78 with integral brake, system includes pump unloading valve. 52L588 Rev D November

12 pplication notes pplication notes CROSS-PORT RELIEF VLVES The cross-port relief valve controls maximum torque of the motor. It provides overpressure protection for the work ports. The cross port relief valve is a full-flow relief. It can bypass all motor flow when pressure reaches the relief setting. The cross-port relief valve is available in configurations with dual (cross-port) valves or with relief on or port only. n optional shuttle valve is also available for load-sensing pumps or auxiliary functions such as brake release. Typical applications for cross-port relief valves include vehicle propulsion, auger drives, conveyer drives, and slew drive. ny rotary application requiring pressure limiting can benefit from a motor-mounted cross-port relief valve. For more information on relief valves, see Relief Valves, section 4 of this catalog. Cross-port relief valve Dual cross-port relief with shuttle S With Shuttle Without Shuttle P F F L588 Rev D November 21

13 pplication notes CROSS-PORT RELIEF VLVES (continued) Sample system circuits with dual cross-port relief typical rotary circuit application for a cross-port relief valve contains a pump, directional control valve, system relief valve, and motor. Without a cross-port relief valve there is no overpressure protection at motor work ports. cross-port relief valve controls motor torque while reducing system component fatigue. In this circuit, a dual cross-port relief HIC is mounted to a standard motor, providing functionality in both directions. Moving the directional control valve to the left causes the motor to rotate in one direction. When the load exceeds the valve setting, the valve opens allowing the flow to bypass to the opposite work port. The cross-port relief valve remains open until the load on the motor decreases below the pressure setting. Dual cross-port relief pplication notes The system relief valve shown in this circuit provides the primary pressure protection. The directional control valve can isolate the pump and motor while shifting, making independent pressure protection necessary. motor-mounted cross-port relief is typically used in circuits where limiting the torque from the load is critical, where the load is very dynamic, or where distance from the system relief limits responsiveness. P Simple rotary circuit with dual cross-port relief valve. 52L588 Rev D November

14 pplication notes CROSS-PORT RELIEF VLVES (continued) with dual cross-port relief, and shuttle operating a brake and unloading valve dding a load sense, or brake shuttle valve allows further functionality. In this circuit, an integral brake and an unloading valve (logic element), are added. The shuttle valve senses the higher pressure work port and provides pressure to release the brake when the system pressure exceeds the minimum brake release pressure. pplication notes When the directional control valve shifts in either direction, pressure builds in the circuit to release the brake and allows the motor to rotate. s shown in the diagram, an orifice provides a slight delay in timing the brake release. When the directional control valve is centered, the brake re-engages. dditionally, the LS pressure signal pilots an unloading valve. When the directional control valve is centered, pressure builds at the outlet of the gear pump and opens the unloading valve, allowing the pump flow to bypass the circuit and exhaust into the reservoir. When the directional control valve shifts in either direction, the unloading valve is piloted to stay in the closed position, thus allowing pump flow to enter the working circuit. Similarly, this LS pressure could communicate flow demand to a load sensing open circuit piston pump. Dual cross-port relief with shuttle S P with integral brake, system includes pump unloading valve L588 Rev D November 21

15 pplication notes YPSS SOLENOID VLVES The bypass solenoid allows an electric signal to enable/disable motor rotation independent of system hydraulics. The normally closed solenoid valve bypasses flow from to when energized. This function is unidirectional. Contact your Comatrol representative if you require reverse logic or if youw ant to use a flow control valve instead of a solenoid. ypass solenoid 1 2 D P14 75 The manifold includes a drain port connected to port to simplify circuit plumbing. Depending on motor drain pressure capabilities, you may connect the motor drain directly to port D on the HIC instead of routing it back to the reservoir. Typical uses for this valve include applications requiring individual motors on the same circuit to be turned off independently, disabling motor during system start-up to limit pressure losses, and on/off fan drive applications. For further information on solenoid valves, see Solenoid valves, section 1 of this catalog. ypass solenoid valve with robust coil pplication notes F F L588 Rev D November

16 pplication notes YPSS SOLENOID VLVES (continued) Sample system circuits with drain, no directional valve typical rotary circuit application for a bypass solenoid valve contains a pump, system relief valve, motor, and in most cases, a directional control valve. The bypass solenoid valve allows an electrically-actuated method of bypassing flow at the motor. pplication notes bypass solenoid valve, when energized, stops the motor rotating by bypassing flow around the motor. In this circuit, a bypass solenoid HIC is mounted to a motor with a drain port, providing functionality in only one direction of motor rotation. The pump provides flow directly to one port of the HIC. ypass solenoid with drain port Flow normally goes through the motor and exits the opposite port to the reservoir. When the bypass solenoid valve is energized, the flow bypasses the motor. This causes the motor to stop rotating even though the pump continues to provide flow. ecause this circuit only flows in one direction, and the HIC drain port connects to the discharge port, the motor drain port can connect directly to the HIC. This simplifies system plumbing. You can eliminate the motor drain line to the reservoir. If the motor does not have a case drain, cap the HIC drain port. D The system relief provides pressure protection in this circuit. circuit similar to this is typically used in systems where the motor only needs to rotate in one direction, a directional control valve is not required, and the application requires the motor to disengage while P This circuit has no directional valve. The solenoid bypass valve controls motor rotation (on/off) L588 Rev D November 21

17 pplication notes YPSS SOLENOID VLVES (continued) the pump flow continues. s in series nother potential application of the solenoid bypass valve is one with two or more motors in series. This circuit contains a pump, directional control valve, system relief valve, and a series of motors with drain ports. The motors rotate in one direction, so the system uses a two-position directional valve. When the directional control valve shifts to the left, flow enters and exits the motor on the right, then through the motor in the middle, through the left motor, then back to the directional control valve and discharges to the reservoir. The function of the solenoid bypass valve in this circuit is to engage and disengage motors that use the same flow source. ny of the three motors can be bypassed individually while maintaining the series flow through the circuit. ecause the drain port connects directly to the discharge port, you cannot use it with motors in series. This circuit is typical of conveyor or auger systems where multiple motors use a common flow source. ypass solenoid valve with motors in series pplication notes D D D P This circuit uses three motors in series with a solenoid operated directional valve and pump relief. 52L588 Rev D November

18 pplication notes pplication notes DUL SHOCK VLVE WITH NTICVITTION CHECKS Dual shock valve with anticavitation checks This valve provides overpressure protection of the motor work ports. It absorbs momentary pressure spikes (shock effects). It is not a full-flow pressure relief valve: Use the dual crossport relief HIC for full-flow pressure protection or torque limitation. The valve D protects the motor from cavitation by allowing additional flow to the motor through the drain port when the motor overruns the pump. This is useful in series wheel-drive applications where one motor must turn faster than the other while the vehicle is cornering. Other applications include auger drives, conveyer drives, slew drives, or any rotary working circuits that experience shock effects. P dual shock valve with anti-cavitation motor mount HIC is typically used in circuits where limiting the torque spikes from the load is critical, where the load is very dynamic, or where distance from the system relief valve causes delayed responsiveness. The anticavitation function is also beneficial in high inertial load applications. ecause the valves seat on the cavity, the housing is made of ductile iron. This limits wear. Only dual valve configurations are available. This HIC uses the PVLP shock valves from our PVG line of flow-sharing directional valves. For more information on PVLP, refer to the PVG 32 Technical Information Manual, 52L344. Dual shock valve with anticavitation checks F F L588 Rev D November 21

19 pplication notes DUL SHOCK VLVE WITH NTICVITTION CHECKS (continued) Sample system circuit Single motor with drain, open center/closed port directional valve typical rotary circuit application for a shock valve with anticavitation contains a pump, directional control valve, system relief valve, and motor. Without this valve there is no over-pressure protection at the motor work ports and no protection against cavitation during overrun. In this circuit, a dual shock valve with anticavitation HIC is mounted to a standard motor, providing functionality in both directions. Moving the directional control valve to the left causes the motor to rotate in one direction. When the motor load exceeds the pressure setting of the shock valve, the valve opens allowing flow to bypass to the drain port. If the drain port is not connected, the flow discharges through the anticavitation check to the opposite system port. The shock valve remains open until the load on the motor decreases below the pressure setting. The system relief valve in this circuit provides full-flow pressure protection close to the gear pump. The shock valves protect the circuit from pressure spikes closest to the load. Dual shock valve with anticavitation checks pplication notes The anticavitation function prevents motor cavitation when the motor overruns pump flow. For anticavitation to function properly, it requires a flow source, typically drawing from the reservoir through the drain port as D P L588 Rev D November 21 Single motor with closed center directional valve and system relief valve. Connection at port D is necessary for anticavitation function

20 pplication notes pplication notes DUL SHOCK VLVE WITH NTICVITTION CHECKS (continued) shown in the circuit. Using anticavitation checks as drain checks pplications that do not require anticavitation protection can use the anticavitation checks as drain checks. Connecting the motor drain directly to the drain port on the HIC allows drain flow to join motor discharge and return to the reservoir through the directional control valve. This saves running a motor drain to the reservoir, but doing this defeats the anticavitation feature: Do not apply the valve in this fashion unless your application never experiences overrunning loads. ecause the drain port is connected to the motor case, pressure spikes in this circuit discharge through the downstream motor port. Dual shock valve with motor drain D P Single motor with drain shown. Connect motor drain to port D on HIC to use anticavitation checks as drain checks. This defeats anticavitation function L588 Rev D November 21

21 MMHIC Test lock OPERTION Use this steel test block for setting or testing motor-mount HICs. It contains the mounting patterns for DH, DS, OMH, OMP, OMR, OMS, and OMT motors. Interface ports are SE. Diagram DH/DS MOUNT OMP/OMR/OMH MOUNT OMS MOUNT OMT MOUNT SPECIFICTIONS Rated pressure 345 bar [5 psi] kg [35.7 lb] Ports 1/1 (DH/DS) SE #6 2/2 (OMP/OMR/OMH) SE #8 3/3 (OMS) SE #8 4/4 (OMT) SE # P14 93 MMHIC Test lock [1.4] [4.4] 73.7 [2.9] 35.6 [1.4] 34.3 [1.35] 39.1 [1.54] 75.2 [2.96] 8. [3.15] 3.5 [1.2] -112 O-ring Spotface 5/16-18 UNC-2 4 Places 3.5 [1.2] 3.5 [1.2] 78.5 [3.9] M8 X Places 78.5 [3.9] [4.51] [4.51] [6.37] M1 X Places [7.23] [7.23] [6.37] [8.95] 25.3 [9.85] 25.3 [9.85] [8.95] [11.] P [1.46] 41.4 [1.63] 73.2 [2.88] 77.1 [3.4] INFORTION Order Number L588 Rev D November

22 MM-DH--DC1-HV OPERTION This is a dual counterbalance HIC that mounts to DH motors with manifold mount porting. P MM-DH--DC1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.49 kg [3.28 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Service mount kit DH CRT. CRT. 4X 5/16-18x63.5mm [2.5in].25in 24.4 Nm [18 lbf-ft] 54.9 [2.16] 86.4 [3.4] [5.16] 79.8 [3.14] 57. [2.25] 22.9 [.9] 62.8 [2.47] 73.9 [2.91] P /16-18x2.5"bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (2X) INFORTION mount code =Novalve Dual counterbalance valve Type HV=Hydraulic Vent MM-DH--DC1-HV-1-C-1-E-1--1S Forpilot ratio (3:1) 1=35-11 bar[ psi] 2=6-15 bar[ psi] 3 = 8-23 bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar[ psi] 2 = bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C(1:1) 1=11-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S=l,#1SE 4 =l, 1/2 SP =una-n sealkit Cracking pressure(bar) Example: 1=1bar[145 psi] See C1-HVfor std. settings djust type E=Externaladjustment F =Tamper resistant Check crack pressure P =1bar (14.5 psi) L588 Rev D November 21

23 MM-DS--DC1-HV OPERTION This is a dual counterbalance HIC that mounts to DS motors with manifold mount porting. P SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.6 kg [3.53 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Service mount kit DS MM-DS--DC1-HV CRT. CRT. 4X 5/16-18x76.2mm [3.in].25in 24.4 Nm [18 lbf-ft] 54.9 [2.16] 86.4 [3.4] [5.16] 57. [2.25] 22.9 [.9] 62.8 [2.47] [3.41] [3.14] P /16-18 x3."bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (4X) -Sub-plate INFORTION mount code =Novalve Dual counterbalance valve Type HV=Hydraulic Vent P MM-DS--DC1-HV-1-C-1-E-1--1S Forpilot ratio (3:1) 1=35-11 bar[ psi] 2=6-15 bar[ psi] 3 = 8-23 bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar[ psi] 2 = bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C(1:1) 1=11-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S=l,#1SE 4 =l, 1/2 SP =una-n sealkit Cracking pressure(bar) Example: 1=1bar[145 psi] See C1-HVfor std. settings djust type E=Externaladjustment F =Tamper resistant Check crack pressure 1=1bar (14.5 psi) 52L588 Rev D November

24 MM-OMP/OMR--DC1-HV OPERTION This is a dual-counterbalance HIC that mounts to OMP/OMR motors with SP porting. P MM-OMP/OMR--DC1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.43 kg [3.15 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Service mount kit OMP/OMR 4X M8x1.25x5mm [1.97in] 6mm 4 Nm [3 lbf-ft] CRT. C1-HV 18.4 [.72] 79.4 [3.12] 96.5 [3.8] [5.16] 44.7 [1.76] 5. [1.97] 61.8 [2.43] P CRT [3.4] 32. [1.26] 54.4 [2.14] -M8x5mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION MM-OMP/OMR--DC1-HV-1-C-1-E-1--1S mount code =Novalve Dual counterbalance valve Type HV=Hydraulic Vent P Forpilot ratio (3:1) 1=35-11 bar[ psi] 2=6-15 bar[ psi] 3 = 8-23 bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar[ psi] 2 = bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C(1:1) 1=11-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S=l,#1SE 4 =l, 1/2 SP =una-n sealkit Cracking pressure(bar) Example: 1=1bar[145 psi] See C1-HVfor std. settings djust type E=Externaladjustment F =Tamper resistant Check crack pressure 1=1bar (14.5 psi) L588 Rev D November 21

25 MM-OMH--DCP441-1 OPERTION This is a dual-counterbalance HIC that mounts to OMH motors with SP porting. P SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 1.93 kg [4.25 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Service mount kit OMH MM-OMH--DCP X M8x1.25x6mm [2.36in] 6mm 4 Nm [3 lbf-ft] CRT. CP [.9] 76.2 [3.] 99.1 [3.9] CRT [1.5] 63.5 [2.5] 11.6 [4.] P [2.47] 74.3 [2.93] 4.4 [1.59] [5.59] -M8x6mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION mount code =Novalve Dual counterbalance valve =una-n 1S=l,#1SE 4 =l, 1/2 SP MM-OMH--DCP S-E sealkit djust type E=Externaladjustment F =Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio3:1 =34-13bar [5-15psi] =13-27bar[15-3 psi] Forpilot ratio4.5:1 =34-138bar [5-2psi] =13-345bar[15-5 psi] Forpilot ratio1:1 =69-345bar [1-5psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 = 1.3 bar (15psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P L588 Rev D November

26 MM-OMS--DCP441-1 OPERTION This is a dual-counterbalance HIC that mounts to OMS motors with SP porting. P MM-OMS--DCP441-1 SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 2.13 kg [4.7 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Service mount kit OMS 2X M1x1.5x6mm [2.36in] 8mm 75 Nm [55 lbf-ft] CP M1x6mmbolts (2X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) CRT. CRT [.65] 95.1 [3.75] [4.4] 11.6 [4.] 38.1 [1.5] 63.5 [2.5] 62.7 [2.47] [1.59] [2.93] 142. [5.59] P14 62 INFORTION mount code =Novalve Dual counterbalance valve =una-n 1S=l,#1SE 4 =l, 1/2 SP MM-OMS--DCP S-E sealkit djust type E=Externaladjustment F =Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio3:1 =34-13bar [5-15psi] =13-27bar[15-3 psi] Forpilot ratio4.5:1 =34-138bar [5-2psi] =13-345bar[15-5 psi] Forpilot ratio1:1 =69-345bar [1-5psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 = 1.3 bar (15psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P L588 Rev D November 21

27 MM-OMT--DCP441-1 OPERTION This is a dual-counterbalance HIC that mounts to OMT motors with SP porting. P SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 2.2 kg [4.85 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Service mount kit OMT MM-OMT--DCP441-1 CRT. CRT. CP X M1x1.5x6mm [2.36in] 8mm 75 Nm [55 lbf-ft] 78.7 [3.1] [4.6] [6.19] 99.1 [3.9] 76.2 [3.] 22.9 [.9] 62.7 [2.47] 71.7 [2.82] P M1x6mmbolts (4X) -(-123)O'rings,Viton (29.82x2.62mm) (2X) INFORTION mount code =Novalve Dual counterbalance valve =una-n MM-OMT--DCP S-E sealkit ody P/N 12S=l, #12 SE =l, 3/4 SP L588 Rev D November 21 djust type E=Externaladjustment F =Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio3:1 =34-13 bar[5-15 psi] =13-27bar[15-3 psi] Forpilot ratio4.5:1 = bar[5-2 psi] =13-345bar[15-5 psi] Forpilot ratio1:1 = bar[1-5psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 = 1.3 bar (15psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P

28 MM-DH--C1-HV OPERTION This is a single-counterbalance HIC ( port) that mounts to DH motors with manifold mount porting. P14 66 MM-DH--C1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.49 kg [3.28 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit DH C1-HV CP1 PLUG 93.5 [3.68] 54.9 [2.16] 86.4 [3.4] [5.16] 4X 5/16-18x63.5mm [2.5in] 1/4in Nm [18 lbf-ft] 79.8 [3.14] 57. [2.25] 22.9 [.9] P [2.47] 73.9 [2.91] -5/16-18x2.5"bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (2X) INFORTION mount code =Novalve Single counterbalance valveon'' port Type HV=Hydraulic Vent MM-DH--C1-HV-1-C-1-E-1--1S Forpilot ratio (3:1) 1=35-11bar [ psi] 2=6-15bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S =l, #1SE 4 =l, 1/2 SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F=Tamper resistant Check crack pressure P = 1bar (14.5 psi) L588 Rev D November 21

29 MM-DS--C1-HV OPERTION This is a single-counterbalance HIC ( port) that mounts to DS motors with manifold mount porting. P14 66 SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.6 kg [3.53 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit DS MM-DS--C1-HV C1-HV CP1 PLUG 93.5 [3.68] 54.9 [2.16] 86.4 [3.4] [5.16] 4X 5/16-18x76.2mm [3.in] 1/4in Nm [18 lbf-ft] 79.8 [3.14] 57. [2.25] 22.9 [.9] P [2.47] 86.6 [3.41] -5/16-18x3."bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (4X) -Sub-plate INFORTION mount code =Novalve Single counterbalance valveon'' port Type HV=HydraulicVent MM-DS--C1-HV-1-C-1-E-1--1S 52L588 Rev D November 21 Forpilot ratio (3:1) 1=35-11 bar [ psi] 2=6-15 bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = 9-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 P S =l,#1se 4 =l, 1/2SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F = Tamper resistant Check crack pressure 1 = 1bar (14.5 psi) 15.29

30 MM-OMP/OMR--C1-HV OPERTION This is a single-counterbalance HIC ( port) that mounts to OMP/OMR motors with SP porting. P14 66 MM-OMP/OMR--C1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.43 kg [3.15 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit OMP/OMR CP1 PLUG C1-HV 4X M8x1.25x5mm [1.97in] 6mm 4 Nm [3 lbf-ft] 18.4 [.72] 79.4 [3.12] 96.5 [3.8] 93.4 [3.68] 44.7 [1.76] 5. [1.97] 61.8 [2.43] P [3.4] 32. [1.26] 54.4 [2.14] -M8x5mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION 15.3 MM-OMP/OMR--C1-HV-1-C-1-E-1--1S mount code =Novalve Single counterbalance valveon'' port Type HV=HydraulicVent 52L588 Rev D November 21 Forpilot ratio (3:1) 1=35-11 bar [ psi] 2=6-15 bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = 9-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S =l, #1SE 4 =l, 1/2SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F=Tamper resistant Check crack pressure 1 = 1bar (14.5 psi) P14 613

31 MM-OMH--CP441-1 OPERTION This is a single-counterbalance HIC ( port) that mounts to OMH motors with SP porting. P14 66 SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 1.93 kg [4.25 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Plug CP12-V-3S-1 Service mount kit OMH MM-OMH--CP X M8x1.25x6mm [2.36in] 6mm 4 Nm [3 lbf-ft] 22.9 [.9] 76.2 [3.] 99.1 [3.9] CP12 PLUG CP [1.5] 63.5 [2.5] 11.6 [4.] 62.7 [2.47] 74.3 [2.93] 11.8 [.46] P [5.59] -M8x6mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION mount code =Novalve Single counterbalance valveon'' port =una-n MM-OMH--CP S-E sealkit djust type E=External adjustment F=Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio 3:1 = bar[5-15 psi] =13-27 bar [15-3 psi] Forpilot ratio 4.5:1 = bar[5-2 psi] = bar [15-5 psi] Forpilot ratio 1:1 = bar[1-5psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 =1.3 bar (15 psi) Pilotratio 3.:1 4.5:1 1.:1 1S =l, #1SE =l, 1/2 SP P Cracking pressure Codex1=psi Example: 5=5 psi 52L588 Rev D November

32 MM-OMS--CP441-1 OPERTION This is a single-counterbalance HIC ( port) that mounts to OMS motors with SP porting. P14 66 MM-OMS--CP441-1 SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 2.13 kg [4.7 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Plug CP12-V-3S-1 Service mount kit OMS 2X M1x1.5x6mm [2.36in] 8mm 75 Nm [55 lbf-ft] 16.5 [.65] 95.1 [3.75] [4.4] CP12 PLUG -M1x6mmbolts (2X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) CP [4.] 38.1 [1.5] 63.5 [2.5] 62.7 [2.47] 74.5 [2.93] 11.8 [.46] 142 [5.59] P INFORTION mount code =Novalve Single counterbalance valveon'' port =una-n 1S =l, #1SE 4 =l, 1/2 SP MM-OMS--CP S-E sealkit L588 Rev D November 21 djust type E=External adjustment F=Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio 3:1 =34-13bar [5-15psi] =13-27 bar [15-3 psi] Forpilot ratio 4.5:1 =34-138bar [5-2psi] = bar [15-5 psi] Forpilot ratio 1:1 =69-345bar [1-5 psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 =1.3 bar (15 psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P14 617

33 MM-OMT--CP441-1 OPERTION This is a single-counterbalance HIC ( port) that mounts to OMT motors with SP porting. P14 66 SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 2.2 kg [4.85 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Plug CP12-V-3S-1 Service mount kit OMT MM-OMT--CP441-1 CP441-1 CP12 PLUG 4X M1x1.5x6mm [2.36in] 8mm 75 Nm [55 lbf-ft] 78.7 [3.1] [5.6] [4.6] [6.19] 99.1 [3.9] 76.2 [3.] 22.9 [.9] 62.7 [2.47] 71.7 [2.82] P M1x6mmbolts (4X) -(-123)O'rings,Viton (29.82x2.62mm) (2X) INFORTION mount code =Novalve Single counterbalance valveon'' port =una-n MM-OMT--CP S-E sealkit Part# 12S=l, #12 SE =l, 3/4 SP L588 Rev D November 21 djust type E=External adjustment F=Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio 3:1 =34-13bar [5-15psi] =13-27 bar [15-3 psi] Forpilot ratio 4.5:1 =34-138bar [5-2psi] = bar [15-5 psi] Forpilot ratio 1:1 =69-345bar [1-5 psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 =1.3 bar (15 psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P

34 MM-DH--C1-HV OPERTION This is a single counterbalance HIC (on port) that mounts to DH motors with manifold mount porting. MM-DH--C1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min P14 62 Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.49 kg [3.28 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit DH CP1 PLUG C1-HV 4X 5/16-18x63.5mm [2.5in] 1/4in Nm [18 lbf-ft] 54.9 [2.16] 86.4 [3.4] 93.5 [3.68] [5.16] 79.8 [3.14] 57. [2.25] 22.9 [.9] 62.8 [2.47] 73.9 [2.91] P /16-18x2.5"bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (2X) INFORTION mount code =Novalve Single counterbalance valveon'' port Type HV=HydraulicVent MM-DH--C1-HV-1-C-1-E-1--1S Forpilot ratio (3:1) 1=35-11 bar [ psi] 2=6-15 bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = 9-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 P S =l,#1se 4 =l, 1/2SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F = Tamper resistant Check crack pressure L588 Rev D November 21

35 MM-DS--C1-HV OPERTION This is a single counterbalance HIC (on port) that mounts to DS motors with manifold mount porting. SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min P14 62 Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.6 kg [3.53 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit DS MM-DS--C1-HV CP1 PLUG C1-HV 4X 5/16-18x76.2mm [3.in] 1/4in Nm [18 lbf-ft] 54.9 [2.16] 86.4 [3.4] 93.5 [3.68] [5.16] 79.8 [3.14] 57. [2.25] 22.9 [.9] 62.8 [2.47] 86.6 [3.41] P /16-18x3."bolts (4X) -(-112)O'rings,Viton (12.37x2.62mm) (4X) INFORTION mount code =Novalve Single counterbalance valveon'' port Type HV=HydraulicVent MM-DS--C1-HV-1-C-1-E-1--1S 52L588 Rev D November 21 Forpilot ratio (3:1) 1=35-11 bar [ psi] 2=6-15 bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18 bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = 9-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 1S =l,#1se 4 =l, 1/2SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F = Tamper resistant Check crack pressure P = 1bar (14.5 psi) 15.35

36 MM-OMP/OMR--C1-HV OPERTION This is a single counterbalance HIC (on port) that mounts to OMP/OMR motors with SP porting. MM-OMP/OMR--C1-HV SPECIFICTIONS psi bar cst [121 SUS] hyd.oil at 5 C [122 F] 3 2 Pilot open Free flow 1 5 P l/min US gal/min P14 62 Rated pressure 21 bar [345 psi] Rated flow at 22 6 l/min [16 US gal/min] bar [319 psi] 6 at 7% of crack pressure 1.43 kg [3.15 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 C1 HV Plug SDC1-V-3S-1 Service mount kit OMP/OMR C1-HV 4X M8x1.25x5mm [1.97in] 6mm 4 Nm [3 lbf-ft] CP1 PLUG 18.4 [.72] 79.4 [3.12] 96.5 [3.8] [5.16] 7.1 [.28] 5. [1.97] 61.8 [2.43] P [3.4] 32. [1.26] 54.4 [2.14] -M8x5mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION MM-OMP/OMR--C1-HV-1-C-1-E-1--1S mount code =Novalve Single counterbalance valveon'' port Type HV=HydraulicVent 52L588 Rev D November 21 Forpilot ratio (3:1) 1=35-11bar [ psi] 2=6-15bar [ psi] 3=8-23bar [ psi] Forpilot ratio (4.5:1) 1=55-18bar [ psi] 2=75-24bar [ psi] 3=9-35 bar [ psi] Forpilot ratio C (1:1) 1 = 9-35 bar [ psi] Pilotratio =3:1 =4.5:1 C=1:1 P S =l,#1se 4 =l, 1/2SP =una-n sealkit Cracking pressure (bar) Example: 1 = 1 bar [145 psi] See C1-HVfor std. settings djust type E=External adjustment F = Tamper resistant Check crack pressure 1 = 1bar (14.5 psi)

37 MM-OMH--CP441-1 OPERTION This is a single counterbalance HIC (on port) that mounts to OMH motors with SP porting. SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E P14 62 Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 1.93 kg [4.25 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Plug CP12-V-3S-1 Service mount kit OMH MM-OMH--CP X M8x1.25x6mm [2.36in] 6mm 4 Nm [3 lbf-ft] CP [.9] 76.2 [3.] 99.1 [3.9] CP12 PLUG 38.1 [1.5] 63.5 [2.5] 11.6 [4.] 62.7 [2.47] 74.3 [2.93] 4.4 [1.59] P [4.46] -M8x6mm bolts (4X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) INFORTION mount code =Novalve Single counterbalance valveon'' port =una-n 1S =l, #1SE 4 =l, 1/2 SP MM-OMH--CP S-E sealkit djust type E=External adjustment F=Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio 3:1 =34-13bar [5-15psi] =13-27 bar [15-3 psi] Forpilot ratio 4.5:1 =34-138bar [5-2psi] = bar [15-5 psi] Forpilot ratio 1:1 =69-345bar [1-5 psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 =1.3 bar (15 psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P L588 Rev D November

38 MM-OMS--CP441-1 OPERTION This is a single counterbalance HIC (on port) that mounts to OMS motors with SP porting. MM-OMS--CP441-1 SPECIFICTIONS psi bar Pressure drop 154 SUS (33 cst) hyd. 1 F (38 C) 25 2 pilot open 15 free flow L/min Flow US gal/min P12 369E P14 62 Rated pressure 21 bar [345 psi] Rated flow at l/min [3 US gal/min] bar [319 psi] 1 at 7% of crack pressure 2.13 kg [4.7 lb] Pilot ratio 3.:1, 4.5:1, 1.:1 CP441-1 Plug CP12-V-3S-1 Service mount kit OMS 2X M1x1.5x6mm [2.36in] 8mm 75 Nm [55 lbf-ft] CP M1x6mmbolts (2X) -(-119)O'rings,Viton (23.47x2.62mm) (2X) 16.5 [.65] 95.1 [3.75] [4.4] CP12 PLUG 11.6 [4.] 38.1 [1.5] 63.5 [2.5] 62.7 [2.47] 74.5 [2.93] 4.4 [1.59] [4.46] P INFORTION mount code =Novalve Single counterbalance valveon'' port =una-n 1S =l, #1SE 4 =l, 1/2 SP MM-OMS--CP S-E sealkit L588 Rev D November 21 djust type E=External adjustment F=Tamper resistant SeeCP441-1 forstd.settings Forpilot ratio 3:1 = bar[5-15 psi] =13-27 bar [15-3 psi] Forpilot ratio 4.5:1 = bar[5-2 psi] = bar [15-5 psi] Forpilot ratio 1:1 = bar[1-5psi] Free flowcheck crackpressure 5 =.34 bar (5 psi) 15 =1.3 bar (15 psi) Pilotratio 3.:1 4.5:1 1.:1 Cracking pressure Codex1=psi Example: 5=5 psi P14 63

Pilot Operated Check Valves Catalog Quick Reference

Pilot Operated Check Valves Catalog Quick Reference Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min

More information

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC

More information

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

Orbital Motors Type OMP X and OMR X

Orbital Motors Type OMP X and OMR X Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Load and Motor Control Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD PILOT ASSISTED CB101... C10-3... Load Control Cartridge Valve...45/12... 380/5500... 5-6 MHC-010-S***

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information , OMT and OMV Orbital Motors Technical Information , OMT and OMV A Wide Range of Orbital Motors Revision History Table of Revisions Date Page Changed Rev ED Dimensions changed EF A Wide Range of Orbital

More information

Orbital Motors Type OMP, OMR and OMH. Technical Information

Orbital Motors Type OMP, OMR and OMH. Technical Information Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Orbital Motors Type VMP. Technical Information

Orbital Motors Type VMP. Technical Information Orbital Motors Type VMP Technical Information A Wide Range of Orbital Motors Revision View Date Page Changed Revision May 213 All First edition AA F31 245 A Wide Range of Orbital Motors Sauer-Danfoss is

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information OMS, OMT and OMV Orbital Motors Technical Information OMS, OMT and OMV A Wide Range of Orbital Motors F300540.eps F300030.TIF A wide range of orbital motors Sauer-Danfoss is a world leader within production

More information

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED] Lecture 19 PRESSURE-CONTROL VLVES [CONTINUED] 1.5 Counterbalance Valve Schematic diagram of counterbalance valve is shown in Fig. 1.14. These normally closed valves are primarily used to maintain a back

More information

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motor VMP powersolutions.danfoss.com Revision History Table of Revisions Date Changed Rev Feb 214 New dimension drawings. Converted to Danfoss

More information

Orbital Motors OMSW with brake nose

Orbital Motors OMSW with brake nose MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMSW with brake nose powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev October 214 Changed to Danfoss layout

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Hydraulics. Hydraulic Pressure Control

Hydraulics. Hydraulic Pressure Control Hydraulics Hydraulic Pressure Control Direct Acting Pressure Relief Valve Normally Closed: Pilot Operated Relief Valve (Compound/ two stage) Small pilot relief valve + Main relief valve Pilot Operated

More information

Cartridge Valves Technical Information Proportional Valves Quick Reference

Cartridge Valves Technical Information Proportional Valves Quick Reference Quick Reference Proportional Directional Model No. Description Flow* Pressure Page PSV-3- SDC- Proportional directional l/min 5. valve [6 ] [36 ] S 3 S Quick reference Proportional Directional Model No.

More information

PTS1120TSJB PTS2120TSTSJB

PTS1120TSJB PTS2120TSTSJB Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.

More information

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS HF42407-07 and HF51912-09 Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features...

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

Priority (Swing) Motors Data and Specifications

Priority (Swing) Motors Data and Specifications s Data and Specifications Specifications HMF 55 HMF 75 HMF 105 cm 3/rev in 3/rev 55 3.36 75 4.57 105 6.40 Pressure Ratings Nominal 5000 PSIG Maximum 6090 PSIG Peak 7250 PSIG Operating Speed Maximum 4100

More information

Orbital Motors OMS, OMT and OMV

Orbital Motors OMS, OMT and OMV MKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMS, OMT and OMV powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 216 Corrected Hardening specification

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Motion Controls Valve locator

Motion Controls Valve locator Motion Controls Valve locator unctional Symbol C C Model Cavity low Rating Typical Pressure Page OCV standard L/min (USgpm) bar (psi) CE A9 (5) 7 (4) - CE A66 (8) 7 (4) - CEH A66 (8) 5 (5) - CE9 A6 9 ()

More information

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features... 3 Hydraulic

More information

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump Sauer Danfoss Series 90 Hydraulic Axial Piston Pump www.hydpump.com 90R030, 90R042, 90R055, 90R075, 90R100, 90R130, 90R180, 90R250 90L030, 90L042, 90L055, 90L075, 90L100, 90L130, 90L180, 90L250 Series

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Introduction. Part one: Identify the Hydraulic Trainer Components

Introduction. Part one: Identify the Hydraulic Trainer Components The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

ANTI SHOCK RELIEF VALVE

ANTI SHOCK RELIEF VALVE ANTI SHOCK RELIEF VALVE Wheeler Road Coventry CV3 4LA England Brüsseler Allee 2 D-41812 Erkelenz Tel. +44(0)2476-217-400 Fax +44(0)2476-217-488 Tel. +49(0)24 31-80 91-0 Fax +49(0)24 31-80 91-19 www.sunhydraulics.com

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter LINDGREN-PIAN, INC. LS-3 / LS-4 Line Setter MOUNTING The Lindgren-Pitman Line Setter should be mounted on or near the transom of the boat such that the line will fall overboard as it leaves the exit. The

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

OMS Technical Information. Versions OMS. Versions

OMS Technical Information. Versions OMS. Versions Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

[You may download this article at: https://fluidsys.org/downloads/ ]

[You may download this article at: https://fluidsys.org/downloads/ ] Fluidsys Training Centre, angalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Introduction INDEX. INTRODUCTION HSE

Introduction INDEX.  INTRODUCTION HSE Introduction INDEX SECTION PAGE INTRODUCTION ORDERING CODE GLOSSARY MOTOR OPTION TECHNICAL SE SE3 / SE5 SE7 / S7 SE9 / S9 SE12 / S12 SE14 / S14 SE14-2 / S14-2 SE17 / S17 SE17-2 / S17-2 SE21 / S21 SE21-2

More information

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated

More information

Accessories. Valves. Adjustable Pressure Relief Valves

Accessories. Valves. Adjustable Pressure Relief Valves Valves djustable Pressure Relief Valves djustable pressure relief valves allow for variable operating pressures anywhere between PSI ( bar). In order to prevent overloading of the motor, however, the maximum

More information

Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com

Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com Contents Function PVG 100 sectional drawing...3 Installation Installation and plug orientation...4

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

Proportional Valve Group PVG 32 Order Specifications

Proportional Valve Group PVG 32 Order Specifications MKING MORN LIVING POSSIL Technical Information Proportional Valve Group powersolutions.danfoss.com Revision History Table of Revisions ate hanged Rev Feb 214 onverted to anfoss layout IT MS J Feb 26 Jan

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001 Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Tools Required: Flow Meter Pressure gauge Holding valve test block Wrenches for installation of

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Introduction to Pneumatics

Introduction to Pneumatics Introduction to Pneumatics Pneumatics Symbols Air generation and distribution Table 1: Symbols use in energy conversion and preparation ITEM SYMBOL MEANING Compressor SUPPLY Pressure Source Pneumatic Pressure

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Proportional Valve Group PVG 32 minibooster

Proportional Valve Group PVG 32 minibooster Technical Information Proportional Valve Group powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2018 Add new modules 0201 August 2015 Drawing updated 00.04 February

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION. GSR500 Ram Assembly General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed

More information

Seal Kits for Orbital Motors. Tech Note

Seal Kits for Orbital Motors. Tech Note for Orbital Motors Revisions Revision History Table of Revisions Date Page Changed Rev Jul 2007 All First edition AA Sep 2007 AB May 2010 12 Japan location BA Sep 2010 12 New back cover BB Jan 2011 3-5

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves Service Bulletin Series PR25MA, PR25P, PR25S, PR32P, PR32S Effective: July 1, 1995 Pilot Operated Pressure Reducing Valves WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

OMS Technical Information Technical data

OMS Technical Information Technical data Technical data TECHNICAL DATA FOR OMS Type OMS OMS OMS OMS OMS OMS OMS OMS OMS OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS Motor size 80 100 125 160 200 250

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

DANFLO Control Valves 400 Series Model 20

DANFLO Control Valves 400 Series Model 20 DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.

More information

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB Engineering & Manufacturing Solutions Specifications: MDC rated for -4 gpm (-151 lpm) MDCF rated for -3 gpm (-114 lpm) Rate for 3 PSI (27 bar) Port Sizes #16 SAE (1-5/16-12) all ports Weighs 16 lbs. (7.3

More information