1 ANTI-ENTRAPMENT PLAN

2 Anti-Entrapment Plan Presenters: Kevin Jeroncic, Alberta Health Services Wade Goin, Alberta Health Services Kelly Carter, Lifesaving Society

3 Session Objectives Defining Entrapment Alberta Health s Proposed Changes to Alberta Pool Standards 2014 Lifesaving Society Anti-entrapment Plan Alberta Health Services Anti-entrapment Checklist

4 Entrapment occurs when: body is held against submerged suction outlet by force of pools suction article of clothing, jewelry, hair or a limb is caught in outlet. What is an Entrapment?

5 Not all entrapments caused by suction Excessive water through a cover can entangle and knot hair Can become physically entrapped as a result of physically being stuck in an outlet or submerged pipe What is an Entrapment?

6 Five Forms of Entrapment 1. Body Entrapment 2. Limb Entrapment 3. Hair Entrapment 4. Mechanical Entrapment 5. Evisceration/ disembowelment

7 Proposed Changes to the Alberta Pool Standards Alberta Health is considering the following antientrapment changes to the Alberta Pool Standards: Improve requirements based on science Provide clarity

8 Proposed Change #1 Some definitions added for clarity. Maximum flow rate Maximum possible flow based on pump running at full speed

9 Proposed Change #2 Operating records must be maintained to provide information regarding (5.1): Proposed - Equipment maintenance, including pump modifications which potentially affect flow rate

10 Proposed Change #3 Water speed and flow are limited so that outlet covers operate safely. Current - Suction outlet cover water velocity maximum 0.5 meters/second (1.5 feet per second) as calculated in Schedule C. Proposed - Manufacturer s flow rate used instead

11 Proposed Change #4 How water flow is divided across multiple outlets is specified for clarity when sizing outlets. Assumes 1 outlet is blocked. Was for pools built after Nov only The table will now apply to existing pools Percent of flow through each unblocked outlet. 2 outlets in total 3 outlets in total 4 outlets in total 5 outlets in total 6 outlets in total >6 outlets in total 100% 50% 33% 25% 20% 100% / (# of open suction outlets)

12 Proposed Change #5 The water flow rate must be known so that outlets can be properly sized. Proposed: Where flow rate cannot be determined an engineer must be consulted

13 Proposed Change #6 As well as safe outlet covers, there must also be suction prevention measures such as dual drains. New options proposed: Outlets on different planes no longer require engineer

14 Proposed Change #6 As well as safe outlet covers, there must also be suction prevention measures such as dual drains. New options proposed: Relaxation for existing dual drains closer than 900 mm centre - centre

15 Proposed Change #6 As well as safe outlet covers, there must also be suction prevention measures such as dual drains. New options proposed: Minimum 66 cm (26 inches) from the outside edge of one cover to the inside edge of the second cover on the same plane

16 Proposed Change #6 66 cm (26 inches) outside - inside edge

17 Proposed Change #7 Outlet problems are dangerous so immediate actions must be taken. Current - immediate closure is required for all outlet problems. Proposed - Options may be considered with AHS to allow the pool to remain open.

18 Deadline for renovations: Current Compliance by November 30, 2017 Proposed Change #8 Proposed - Drain or outlet changes extended to November 2019 Vacuum and skimmer equalizer lines still require safe covers by November 2017

19 Going Forward Nothing has changed as of today. Operators still have to meet the requirements as outlined in the 2014 Pool Standards and Alberta Swimming Pool, Wading Pool, and Water Spray Park Regulation. You now have a heightened awareness that some changes may be coming.

20 Lifesaving Society Anti-entrapment Plan Next module of the Lifesaving Society Aquatic Manual Template

21 Anti-entrapment Plan Required under legislation Template to assist owners and their agents Includes inspection of anti-entrapment devices

22 Content Definitions Anti-entrapment devices Installation information Compliance documentation Plan for compliance Map of anti-entrapment devices Inspection checklist

23 COMPLIANCE STRATEGY Note Pool Owner / Owner s Agent This form has been created to asssit your facility to achieve compliance with the ANSI Anti-entrapment requirements detailed in the Alberta pool Standards (2014). This form is designed to assist you in tracking steps taken to achieve compliance. 1. Surveying the Facility How many section outlet does the facility have Are all of the suction oulets ANSI/APSP performance standards certified 1.a If you awnsered no to the above question, please awnser the following questions: How many suction outlet covers comply with the ANSI or APSP performance standards: How many sction oulet covers do not comply with the ANSI or APSP performance standards When will you order the new covers? When will the new covers be installed? 1b. Individual/Company/Engineer responsible for the work (if different from the Owner or Owner s agent) Name Company Name Yes No Phone 2. Proposed work to be completed Drain Cover Location Proposed Compliant Cover Planned Installation 1. Dive Tank Drain #1 Hayward Dual Suction Outlet, 9 January 10, 2017 square high flow sump with cover 2. INSERT LOCATION INSERT DESCRIPTION INSERT DATE Compliance Date of complance Owner / Owners Agent Signagture

24 Anti-entrapment Inspections Fall Forum Anti-entrapment Session

25

26 Alberta Health Services Anti-entrapment Checklist Purpose: Ensure the anti-entrapment plan is acceptable Provide an audit tool for self-assessment Provide a record for the facility to prove compliance (e.g. during inspection or for 2019)

27 Components: AHS Checklist Flow chart Checklist Appendices: Maximum flow rate (finding GPM) Flow division through outlets Outlet sumps

28

29 Part II Public Swimming Pool Information Pool Location Indoor Pool Outdoor Pool Pool Type Swimming Pool Whirlpool (<4000L) Waterslide Receiving Pool Submerged Suction Outlet Connected To: Wading Pool Whirlpool (>4000L) Other (specify): Spray Feature Slide Hydro-Jet Recirculation Other (specify): Part III Suction Outlet Entrapment Assessment Information (See Part A of Flowchart) Detail Response Additional Information How many pumps does the outlet(s) serve? If 2 or more pumps are connected to one set of outlets then the maximum system flow rate will be the added flows (combination) of all pumps connected to it. Pump manufacturer, make, model number, horsepower of pump What is the maximum flow rate? Refer to Appendix A for details If available you may include manufacturer s specifications such as pump curve and manual. Include any supporting documents such as photos of flow meter, gauges and devices used for calculation How was the maximum flow rate determined? (please circle one) a) Pump method 1 flow meter b) Pump method 2 pressure/vacuum gauge (TDH) c) Maximum pump flow according to pump curve d) Ultrasonic flowmeter How many suction outlets are connected to the common suction line piped to the pump(s) listed above? Suction outlet details Manufacturer, make, model,maximum flow rating of cover A plumbing diagram should be included to clarify the plumbing of each system. Include a copy of certificate of compliance for the suction outlets. Is the outlet certified to ANSI/APSP-16? Does each outlet system have a cover with a flow rating equal to, or greater than the maximum flow rate? Refer to Appendix B Is the outlet cover within the operating lifespan based on the installation date and marked life? Installation date: Life span according to manufacturer: Expiry date:

30 What type of sump is in use? Does the sump meet the manufacturer s requirements? See Appendix C How is the outlet cover installed to the sump? If existing frame is in use, is the frame cracked, broken or damaged? Is the cover securely attached to a sump or fitting? Was the manufacturer s required hardware used to secure the cover (such as stainless steel screws, anchors, adapters, etc)? Upon visual inspection is the cover undamaged (cracked or broken)? Has the cover been installed according to manufacturer s specifications? Is the center-to-center distance between the outlets no less than 90 cm (36 inches)? (Include measured distance) Is the distance from the outside edge of one outlet to the inside edge of the second outlet no less than 66cm (26 inches)? Are the outlets on different planes? a) Manufactured sump b) Field fabricated a) Existing frame b) New frame c) Secured directly to the pool basin All covers are not compliant with all sumps and fittings. Replace with compatible cover and/or create compliant sump per cover manufacturer s instructions. Include a diagram with the dimensions of the sump. If cover is approved by manufacture for sumpless install please include note. Ensure manufacturer s installation requirements are met Do not modify the cover or frame (such as drilling new holes) unless specified by manufacturer. Use required adapter if necessary. If frame is damaged it must be replaced. Manufacturer supplied hardware is corrosion resistant. Some covers may need additional security such as epoxy for installation. Refer to manufacturer s specification. All submerged suction outlets must be visually inspected on a daily basis. This must be documented by the facility. If cover was not installed according to manufacturer s specification approval by a professional engineer or manufacturer s confirmation approving the modification is required. For systems with 3 or more interconnected outlets the measurement is centre to centre for the most widely spaced outlets of the group. For systems with 3 or more interconnected outlets the measurement is from the outside edge of one outlet to the inside edge of the most widely spaced outlet of the group. E.g. one (1) on the bottom and one (1) on the vertical wall, or one (1) each on two (2) separate vertical walls. Suction outlets shall not be installed in seating areas.

31 Are the outlets interconnected? Include information on how this was confirmed e.g. engineered drawing, line location, pool service professional. Are any outlets unblockable? Include appropriate drawings and information as required. Refer to Pool Standards, 2016 for definition of unblockable suction outlet.

32 Part IV Secondary Anti-Entrapment Device (See Part B of Flowchart) Does the facility have any of the following, if yes move to part V. If no, then complete remaining sections of Part IV Unblockable outlet in accordance with ANSI/APSP-16 Multiple outlets with adequate flow ratings, and with centre to centre distance between the covers of at least 36 inches Drains on different planes What secondary anti-entrapment system is employed? Safety Vacuum Release System (SVRS) Permanently disable the single outlet. Verify that the overflow and skimmers are capable of handling the required system flow and that minimum turnover rates are achieved.* Automatic pump shut off A gravity flow system able to safely limit suction* Suction-limiting vent system Convert single suction outlet to return inlet by changing the piping, provided that the system piping and skimmer(s) are capable of handling the full system flow* Other* (specify): * These systems will require review and approval by a professional engineer What secondary anti-entrapment device is installed? Make, model,device type: Include any supporting documents such as manufacturer s manuals and certificate of installation. Install date: Expiry date: (if applicable) Initial calibration pressure or setting: Does the device meet relevant ASTM/ASME standards? Has the anti-entrapment system been tested and functions according to manufacturer s specification? How is the system routinely tested and inspected to ensure compliance? Include details and frequency Is routine testing and maintenance documented? Has an engineer or suitable professional certified the installation?.

33 Has the device been installed according to manufacturer s specifications? Part V Other Submerged Suction Outlet (See Part C of Flowchart) Detail Result Information Is there a skimmer equalizer line or submerged suction outlet used for vacuuming? Is there a cover on the skimmer equalizer lines or are they permanently sealed or disabled? An ANSI/APSP-16 approved outlet cover is strongly recommended. Is there a fitted lid (cover), self closing cover, a plug or other means to prevent entrapment (cover tested to IAPMO-SPS 4) on the vacuum line? Are there additional submerged outlets or openings in the pool where entrapment may occur? Detail what methods have been used to prevent entrapment for other identified submerged outlets or openings.

34 Thank You Contact Information: Kevin Jeroncic, Aquatic Program Coordinator Edmonton Alberta Health Services Wade Goin, Public Health Inspector Alberta Health Services - South Zone (Lethbridge & Medicine Hat areas) wade.goin@albertahealthservices.ca Kelly Carter, Executive Director Lifesaving Society Kellyc@lifesaving.org Fall Forum Anti-entrapment Session

Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act

Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act Sponsored by the U.S. Consumer Product Safety Commission Presented By: Rick English, Certified Building Professional, CPOI

More information

NOTICE. SDX HIGH FLOW SAFETY DRAIN For Concrete, vinyl & equalizer pools OWNER S MANUAL & INSTALLATION GUIDE

NOTICE. SDX HIGH FLOW SAFETY DRAIN For Concrete, vinyl & equalizer pools OWNER S MANUAL & INSTALLATION GUIDE NSF/ANSI 50 SDX HIGH FLOW SAFETY DRAIN For Concrete, vinyl & equalizer pools OWNER S MANUAL & INSTALLATION GUIDE VGB 2008 COMPLIANT MDX 2 & SDX DRAINS ARE COMPLIANT WITH THE VIRGINIA GRAEME BAKER ACT 2008.

More information

GUIDELINE FOR MITIGATING SUCTION HAZARDS IN POOLS

GUIDELINE FOR MITIGATING SUCTION HAZARDS IN POOLS GUIDELINE FOR MITIGATING SUCTION HAZARDS IN POOLS JUNE 2014 HEALTH AUTHORITY RECREATIONAL WATER COUNCIL Mitigating Suction Hazards in Swimming Pools Main-drains and other suction points in swimming pools

More information

NOTICE WARNING DANGER SDX2 HIGH FLOW SAFETY DRAIN FOR CONCRETE OWNER S MANUAL MAINTENANCE & INSTALLATION GUIDE. VGB 2008 Compliant

NOTICE WARNING DANGER SDX2 HIGH FLOW SAFETY DRAIN FOR CONCRETE OWNER S MANUAL MAINTENANCE & INSTALLATION GUIDE. VGB 2008 Compliant NSF/ANSI 50 VGB 2008 Compliant MADE IN USA SDX2 HIGH FLOW SAFETY DRAIN FOR CONCRETE OWNER S MANUAL MAINTENANCE & INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR SINGLE OR MULTIPLE DRAIN USE FOR USE ON

More information

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance 2009 International Family of Codes Swimming Pools and Spas 2009 International Building Code 2009

More information

CIPHI 2017 Annual Education Conference

CIPHI 2017 Annual Education Conference CIPHI 2017 Annual Education Conference Michael Wu, M. Sc., P.Eng. Public Health Engineer, VCH Jessica Ip, BSc(Hons), MBA, CPHI(C) Senior Environmental Health Officer, VCH Pool Suction Hazards Contents

More information

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX) Only for Pools with an existing MDX sump ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX) Safety compliant according to the Virginia Graeme Baker

More information

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting APSP/ANSI-7 Writing Committee APSP/ANSI/ICC-15 Writing Committee APSP/ANSI/ICC-5 Writing Committee (Chairman) International Swimming Pool

More information

Pool Standards 2014 (Amended 2017)

Pool Standards 2014 (Amended 2017) Pool Standards 2014 (Amended 2017) How Did We Get Here? Continued Challenge: Respond to New Evidence Provincial Aquatic Committee (AHS) Two anti-entrapment workshops Meetings with Industry: Anti-entrapment

More information

Summary of Substantive Changes between the 2003 and the 2014 editions of ANSI/APSP/ICC 1 American National Standard for Public Swimming Pools

Summary of Substantive Changes between the 2003 and the 2014 editions of ANSI/APSP/ICC 1 American National Standard for Public Swimming Pools Summary of Substantive Changes between the 2003 and the 2014 editions of ANSI/APSP/ICC 1 American National Standard for Public Swimming Pools Presented to the IAPMO Standards Review Committee on December

More information

The Virginia Graeme Baker Pool and Spa Safety Act. by and does not necessarily represent the views of the Commission.

The Virginia Graeme Baker Pool and Spa Safety Act. by and does not necessarily represent the views of the Commission. The Virginia Graeme Baker Pool and Spa Safety Act This information was prepared by the CPSC staff; it has not been approved This information was prepared by the CPSC staff; it has not been approved by

More information

I. Site Information. Pump Information

I. Site Information. Pump Information California Department of Public Health Compliance Form for Public Pools and Spas Health and Safety Code Sections 116064.1 and 116064.2,> INSTRUCTIONS FOR COMPLETING THE COMPLIANCE FORM Use one form for

More information

MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant

More information

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN CLACKAMAS COUNTY COMMUNITY HEALTH DIVISION ENVIRONMENT & HEALTH SERVICES APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN APPLICATION IS HEREBY MADE

More information

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 1 Safety compliant according

More information

Alberta Health. Pool Standards July 2014 (Amended January 2018)

Alberta Health. Pool Standards July 2014 (Amended January 2018) Alberta Health Pool Standards July 2014 (Amended January 2018) Government of Alberta Department Alberta Health Title Author Authority Public Health and Compliance Section 66(4) of the Public Health Act,

More information

PUBLIC SWIMMING POOLS REGULATION

PUBLIC SWIMMING POOLS REGULATION Province of Alberta PUBLIC HEALTH ACT PUBLIC SWIMMING POOLS REGULATION Alberta Regulation 204/2014 Extract Published by Alberta Queen s Printer Alberta Queen s Printer 7 th Floor, Park Plaza 10611-98 Avenue

More information

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 PUBLIC SPA CHECKLIST This checklist is prepared for purposes of convenience only. For accurate

More information

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS SWIMMING POOLS (IN-GROUND OR ABOVE-GROUND), SPAS AND HOT TUBS (CONTAINS WATER OVER 24 INCHES DEEP) Please read all of the following

More information

VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT

VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT CPSC STAFF S GUIDE TO COMPLYING WITH THE LAW By December 19, 2008, ALL public pool owners/operators must: Install drain covers that meet the ANSI/ASME A112.19.8

More information

Cynthia Arias Pollution Control Coordinator

Cynthia Arias Pollution Control Coordinator Cynthia Arias Pollution Control Coordinator cynthia.arias@cityofcarrollton.com 972-466-3059 28 cities surveyed 100% were inspecting public and semi-public pools Based on Texas Department of State Health

More information

Code Compliance Incorporated

Code Compliance Incorporated Telephone Facsimile 352/473-4070 352/473-1080 REPORT REGARDING CURRENT NATIONAL STANDARDS FOR ENTRAPMENT PREVENTION AND INVESTIGATION OF DUAL-DRAIN, STEVEN S VENT, U-TUBE VENT PIPE, AND FLORIDA VENT PIPE

More information

VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT

VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT VIRGINIA GRAEME BAKER POOL & SPA SAFETY ACT CPSC STAFF S GUIDE TO COMPLYING WITH THE LAW By December 19, 2008, ALL public pool owners/operators must: Install drain covers that meet the ANSI/ASME A112.19.8

More information

Swimming Pool Requirements

Swimming Pool Requirements Swimming Pool Requirements 1. Definitions: Approved Safety Pool Cover. Means a manually or power-operated safety pool cover that meets all of the performance standards of the American Society for Testing

More information

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 2. DECK AND COPING MUST BE IN GOOD REPAIR AND PROPERLY DRAINED. (.

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 2. DECK AND COPING MUST BE IN GOOD REPAIR AND PROPERLY DRAINED. (. A. DECKS WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 1. FENCING MUST BE IN GOOD REPAIR. (.21) A. MINIMUM 6 FT FOR MAIN POOL. B. MINIMUM 3 FT FOR WADING POOL SEPARATION FENCE.

More information

Welcome to the PMG Educational Program. Sponsored by:

Welcome to the PMG Educational Program. Sponsored by: Welcome to the PMG Educational Program Sponsored by: www.iccsafe.org/conference #ICCAC18 Today s Presenter Layers of Protection 2018 ISPSC Carvin DiGiovanni Vice President, Technical and Standards Association

More information

BERMUDA GUNITE SKIMMER FOR SWIMMING POOLS

BERMUDA GUNITE SKIMMER FOR SWIMMING POOLS 1 1 1 BERMUDA GUNITE SKIMMER FOR SWIMMING POOLS INSTALLATION AND USER S GUIDE Rev. G 6-26-12 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS MASTERTEMP Pool and Spa

More information

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (.

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (. WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS A. DECKS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (.13) 2. LIFELINE IN PLACE AND SECURE AND A 4" MINIMUM

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR SPECIAL USE SUCTION FITTINGS FOR SWIMMING POOLS, SPAS AND HOT TUBS (FOR SUCTION SIDE AUTOMATIC SWIMMING

More information

Swimming Pools, Hot Tubs and Spas

Swimming Pools, Hot Tubs and Spas OLATHE FIRE DEPARTMENT BUILDING CODES 1225 S. Hamilton Circle Olathe, KS 66061 / Main: (913) 971-7900 / Fax: (913) 971-9812 Swimming Pools, Hot Tubs and Spas Definitions: Swimming Pool- Any structure intended

More information

COMPLIANCE WITH STANDARDS, REGULATIONS AND ORDINANCES

COMPLIANCE WITH STANDARDS, REGULATIONS AND ORDINANCES INTRODUCTION TO THE BUILDER Your safety and that of your family and friends is of vital concern to all of us. When installed and used properly, swimming pools provide many hours of safe, healthy fun and

More information

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 - GENERAL POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS AG101.1 General. The requirements of this appendix shall apply to the design and construction

More information

Existing Rule Language Compared to Proposed Rule Language

Existing Rule Language Compared to Proposed Rule Language Existing Rule Language Compared to Proposed Rule Language MINNESOTA RULES, CHAPTER 4717; REVISOR S ID NUMBER 4442 The following table is a summary of existing and proposed rules. For complete regulations

More information

TITLE XIV POOL AND SPA SAFETY

TITLE XIV POOL AND SPA SAFETY Virginia Graeme Baker Pool and Spa Safety Act. 15 USC 8001 note. 15 USC 8001. TITLE XIV POOL AND SPA SAFETY SEC. 1401. SHORT TITLE. This title may be cited as the Virginia Graeme Baker Pool and Spa Safety

More information

Vertical and Horizontal Bladder Tanks

Vertical and Horizontal Bladder Tanks DATA SHEET Vertical and Horizontal Tanks Application The ANSUL bladder tank is one component in a balanced pressure proportioning system. Its operation requires no external power other than a pressurized

More information

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS Effective January 1, 2017 PLAN SUBMITTAL Any person proposing to renovate, replaster, reconstruct or alter a public pool or its ancillary facilities,

More information

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool Jackson County Department of Public Health 538 Scotts Creek Rd. Suite 100 Sylva, NC 28779 Tel: 828-586-8994 FAX: 828-586-3493 Shelley Carraway DIRECTOR Jackson County Department of Public Health Application

More information

U.S. CONSUMER PRODUCT SAFETY COMMISSION WASHINGTON, D.C November 23, 2004

U.S. CONSUMER PRODUCT SAFETY COMMISSION WASHINGTON, D.C November 23, 2004 U.S. CONSUMER PRODUCT SAFETY COMMISSION WASHINGTON, D.C. 20207 November 23, 2004 Dear Colleague: Since the release of Guidelines for Entrapment Hazards: Making Pools and Spas Safer (guidelines) in January

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Chapter 10 SWIMMING POOLS

Chapter 10 SWIMMING POOLS 4-10-1: COMPLIANCE REQUIRED: Chapter 10 SWIMMING POOLS It shall be unlawful to construct, maintain, install or enlarge any swimming pool in the City except in compliance with the provisions of this Chapter.

More information

ENVIRONMENTAL HEALTH DIVISION POOL SAFETY 2017 UPDATES

ENVIRONMENTAL HEALTH DIVISION POOL SAFETY 2017 UPDATES EN[Type text]vironmental HEALTH DEPARTMENT OF PUBLIC HEALTH Kathleen Grassi, R.D., M.P.H. Director Ron Rowe, R.E.H.S., M.P.A. Environmental Health Director ENVIRONMENTAL HEALTH DIVISION POOL SAFETY 2017

More information

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax: Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC 28092 Phone: 704-736-8426 Fax: 704-736-8427 APPLICATION FOR APPROVAL TO CONSTRUCT OR RENOVATE A PUBLIC SWIMMING

More information

Aquatic Facilities Water Spray/Play Ground Application, Design & Operating Requirements Environmental Health Guide

Aquatic Facilities Water Spray/Play Ground Application, Design & Operating Requirements Environmental Health Guide Aquatic Facilities Water Spray/Play Ground Application, Design & Operating Requirements Environmental Health Guide Water Play/Spray Grounds are aquatic facilities where patrons (primarily children) become

More information

Introducing the 2015 ISPSC

Introducing the 2015 ISPSC Introducing the 2015 ISPSC International Swimming Pool and Spa Code (ISPSC) Goal The goal of this seminar is to highlight the 2015 International Swimming Pool & Spa Code (ISPSC). 2012 ISPSC Introduction

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH

FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH REGARDING PROPOSED CHANGES TO THE CALIFORNIA BUILDING STANDARDS, ADMINISTRATIVE CODE CALIFORNIA CODE OF

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

In this presentation we will talk about Florida Administrative Code, 64E-9 and how it regulates swimming pools and pool operator s responsibilities.

In this presentation we will talk about Florida Administrative Code, 64E-9 and how it regulates swimming pools and pool operator s responsibilities. In this presentation we will talk about Florida Administrative Code, 64E-9 and how it regulates swimming pools and pool operator s responsibilities. 1 Chapter 64E-9 is the section of the Florida Administrative

More information

TITLE XIV POOL AND SPA SAFETY

TITLE XIV POOL AND SPA SAFETY 1 2 4 5 TITLE XIV POOL AND SPA SAFETY SEC. 01. SHORT TITLE. This title may be cited as the Virginia Graeme Baker Pool and Spa Safety Act. SEC. 02. FINDINGS. Congress finds the following: (1) Of injury-related

More information

G.B. Collins Engineering, P.A. Comments to Proposed Code Modification SW7074-A1

G.B. Collins Engineering, P.A. Comments to Proposed Code Modification SW7074-A1 G.B. Collins Engineering, P.A. Comments to Proposed Code Modification SW7074-A1 I. REFERENCES: CURRENT CODE PROVISIONS Florida Building Code, 5th Edition (2014) Chapter 4 Special Detailed Requirements

More information

BUILDING STANDARDS INFORMATION BULLETIN 17-08

BUILDING STANDARDS INFORMATION BULLETIN 17-08 DEPARTMENT OF GENERAL SERVICES 2525 Natomas Park Drive, Suite 130 Sacramento, California 95833-2936 (916) 263-0916 FAX (916) 263-0959 GOVERNOR EDMUND G. BROWN JR BUILDING STANDARDS INFORMATION BULLETIN

More information

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL Topics to cover: Pool & Spa Energy Code Requirements Residential Code Requirements Building (Public) Code Requirements

More information

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET Sect. 106-748, City Code of Ordinances: Regulations are applicable to both above and inground swimming pools, spas and hot tubs. POOL PLACEMENT Measurement

More information

GREIG FILTERS, INC. OPERATION MANUAL

GREIG FILTERS, INC. OPERATION MANUAL GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Safety Standards for Canadian Swimming Pools and Waterfronts Swimming Pool Standard

Safety Standards for Canadian Swimming Pools and Waterfronts Swimming Pool Standard 287 McArthur Avenue, Ottawa, Ontario K1L6P3 Telephone: 613-746-5694 E-mail: experts@lifesaving.ca Web: www.lifesaving.ca Standard Pool Operator Training Standard Pool Operator training shall include the

More information

Summary of Substantive Changes between the 1999 and the 2014 editions of ANSI/APSP/ICC 3 Permanently Installed Residential Spas

Summary of Substantive Changes between the 1999 and the 2014 editions of ANSI/APSP/ICC 3 Permanently Installed Residential Spas Summary of Substantive Changes between the 1999 and the 2014 editions of ANSI/APSP/ICC 3 Permanently Installed Residential Spas Presented to the IAPMO Standards Review Committee on January 8, 2018 General:

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

New Jersey State Sanitary Code Chapter IX Public Recreational Bathing N.J.A.C. 8:26 Changes 1/16/18

New Jersey State Sanitary Code Chapter IX Public Recreational Bathing N.J.A.C. 8:26 Changes 1/16/18 ALL POOLS The definition of Altered and Alteration has changed to include the change of any item that is not with the same or newer model number. Definitions changed for aquatic recreation facility, Operator

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

B o a r d o f H e a l t h

B o a r d o f H e a l t h B o a r d o f H e a l t h April 3, 2018 2018 Public Recreational Bathing License Application Dear Pool Owner: Enclosed you will find an application for the 2018 Public Recreational Bathing License and

More information

COUNTY OF SANTA CRUZ

COUNTY OF SANTA CRUZ COUNTY OF SANTA CRUZ December 5,2006 PLANNING DEPARTMENT 701 OCEAN STREET, qth FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 TOM BURNS, PLANNING DIRECTOR AGENDA DATE:

More information

2009 NEW MEXICO SWIMMING POOL, SPA AND HOT TUB CODE

2009 NEW MEXICO SWIMMING POOL, SPA AND HOT TUB CODE TITLE 14 CHAPTER 8 PART 3 HOUSING AND CONSTRUCTION PLUMBING CODES 2009 NEW MEXICO SWIMMING POOL, SPA AND HOT TUB CODE 14.8.3.1 ISSUING AGENCY: Construction Industries Division (CID) of the Regulation and

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

FACILITY CONDITION ASSESSMENT

FACILITY CONDITION ASSESSMENT FACILITY CONDITION ASSESSMENT R. C. Icabone Swimming Pool 1131 College Ave. Cañon City, CO Terracon Project No. BE186084 Prepared For: Cañon City Area Recreation and Park District, 575 Ash Street Cañon

More information

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION 2700 M Street, Suite 300 Bakersfield, CA 93301 Phone (661) 862-8740 Fax (661) 862-8701 POOL DATA PUBLIC SWIMMING POOL, SPA, WADING

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Piped Air SCBA Refilling System Standard

Piped Air SCBA Refilling System Standard WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Piped Air SCBA Refilling System Standard SCOPE: This specification

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TROUBLESHOOTING GUIDELINES

TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST Pool Name: Address: Contractor: Phone: Number of Pools Applied for: GENERAL INFORMATION Plan review paid Pool Piping plan stamped by Design Professional.

More information

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre Revision Date: 5/17/2016 Page: 1 of 13 Health & Safety has developed the emergency eyewash & safety shower equipment procedure which will be implemented in 3 phases over the next four years. Phase 1 will

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements

More information

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button

More information

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant according

More information

International Swimming Pool and Spa Code (ISPSC ) The goal of this seminar is to highlight the 2015 International Swimming Pool & Spa Code (ISPSC).

International Swimming Pool and Spa Code (ISPSC ) The goal of this seminar is to highlight the 2015 International Swimming Pool & Spa Code (ISPSC). 2015 ISPSC Overview International Swimming Pool and Spa Code (ISPSC ) Goal The goal of this seminar is to highlight the 2015 International Swimming Pool & Spa Code (ISPSC). 2 Copyright 2016 International

More information

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives)

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives) Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives) December 5, 1994 TM Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on

More information

Warning: NEVER ALTER TEST EQUIPMENT

Warning: NEVER ALTER TEST EQUIPMENT PAGE 1 OF 6 General: Pressure Testing Shop Built Tanks Pressure testing tanks with either positive pressure or vacuum can be a very dangerous exercise. It is important to understand the equipment involved

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory

More information

User Manual for the Mars Calibration Bench

User Manual for the Mars Calibration Bench User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Office Use Only Fee Paid

Office Use Only Fee Paid WASHOE COUNTY HEALTH DISTRICT ENVIRONMENTAL HEALTH SERVICES DIVISION 1001 East Ninth Street PO Box 11130 Reno, Nevada 89520 Telephone (775) 328-2434 Fax (775) 328-6176 www.washoecounty.us/health APPLICATION

More information

TOWN OF FARMINGTON DEPARTMENT OF PUBLIC WORKS & DEVELOPMENT SERVICES. Russell M. Arnold Jr., P.E. Director/Town Engineer (860)

TOWN OF FARMINGTON DEPARTMENT OF PUBLIC WORKS & DEVELOPMENT SERVICES. Russell M. Arnold Jr., P.E. Director/Town Engineer (860) TOWN OF FARMINGTON DEPARTMENT OF PUBLIC WORKS & DEVELOPMENT SERVICES Russell M. Arnold Jr., P.E. Director/Town Engineer (860) 675-2305 BUILDING, ENGINEERING, PLANNING and ZONING DIVISIONS Christopher Foryan,

More information

Virginia Graeme Baker Pool and Spa Safety Act; Unblockable Drain Rule

Virginia Graeme Baker Pool and Spa Safety Act; Unblockable Drain Rule UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION 4330 EAST WEST HIGHWAY BETHESDA, MD 20814 This document has been electronically approved and signed. : September 7, 2011 TO THROUGH: The Commission Todd

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW Pool Name: Address: Contractor: Phone: Number of Pools Applied for: The following is a list of facility requirements for opening a public pool. Read each requirement

More information

Industry update on Ontario s Public Pools and Recreational Camps Regulations under the Health Protection and Promotion Act

Industry update on Ontario s Public Pools and Recreational Camps Regulations under the Health Protection and Promotion Act Industry update on Ontario s Public Pools and Recreational Camps Regulations under the Health Protection and Promotion Act Health Improvement Policy and Programs Branch July 24, 2018 Purpose: To update

More information

DUAL SUCTION OUTLETS

DUAL SUCTION OUTLETS ISWG1061 Rev A DUAL SUCTION OUTLETS Contents Product Specific Warnings 2 Recommended system specifications... 5 Installation.... 6 Replacement Parts... 6 Owner s Manual Model No.: WG1061HF2PAK2 and WG1061LV2PAK2

More information

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE NOTICE WARNING To Installers: Read and follow these instructions. Give these instructions to the facility owner to keep for future reference.

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE Inspections & Permits Department 316 North Academy Street Cary, NC 27513 (919) 469-4046 Fax: (919) 462-3840 Email: BuildingSafety@townofcary.org www.townofcary.org RESIDENTIAL SWIMMING POOLS, SPAS and