1 Contents Data Sheet SS/S261EN Rev. 0 S T Series Pressure Transmitters Engineered solutions for all applications Measurement made easy Wide range of remote seal types llows optimum design for each application without compromising performance Large selection of options, materials and fill fluids Meets nearly all process requirements Designed for use with the 2600T pressure transmitter Combines an economically feasible and technically sound solution that ensures total reliability from line pressure to full vacuum Special designed remote seals for individual process solutions dded flexibility for the most demanding processes
2 Data Sheet 2600T Series Pressure Transmitter S T Series Pressure Transmitter S261 SS/S261EN Rev. 0 Contents 1 Remote Seals Overview Seal system selection criteria Ordering information Fill fluid properties (Table )... 2 S261W Model Wafer Remote Seal Mounting examples Seal dimensions Specifications Temperature effect Ordering information... 3 S261F Model Flanged Flush and Extended Diaphragm Remote Seal Seal dimensions Specifications Temperature effect Ordering information S261M model offline flanged connection remote seal Seal dimensions Specifications Temperature effect Ordering information S261J Model Inline Remote Seal (without flanges) Seal dimensions Specifications Temperature effect Ordering information
3 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 pprovals 1 Remote Seals Overview The S261 seals are used in combination with 261 transmitters for gauge or absolute pressure measurements. The seal is connected to the relevant transmitter via a capillary system that links the transmitter sensor to a "remote" seal of any type. The S26 Series Seal System is a protective device used to isolate 2600T series transmitters from the process fluid. The seal system provides a flexible diaphragm between the process fluid and a liquid filled capillary tube connected to the body of the transmitter. The diaphragm isolates the process fluid while the filled capillary tube hydraulically transmits the process pressure to the transmitter sensor. The remote seal capillary is corrosionresistant with robust construction in stainless steel with spiral armor protection, and an optional PVC jacket. For certain applications, it is necessary to use a remote seal in order to suit specific process conditions, e.g.: The process fluid has solids in suspension or is highly viscous and can foul impulse lines. The process fluid can solidify in impulse lines or the transmitter. The transmitter must be located in a separate area from a hazardous process fluid. The process temperature exceeds the recommended limits for the transmitter. The transmitter must be located in a separate area from the process for easier maintenance. The S26 series is available with process connections for SME or DIN pipe flanges. Extended diaphragm remote seals, suitable for connection to 2, 3 or inch resp., DN 0 or DN 100 flanged tank nozzles or flanged tees, permit the seal diaphragm to be located flush with the inside of a tank or pipe. FD approved fillings and compliance with 3 Sanitary Standards are also available. Fill fluids with FD approval are defined as food fills and are Generally Recognized s Safe (GRS) by the US Food and Drug dministration (FD). 1.1 Seal system selection criteria The application of an S26 system in direct mount or remote seal configuration to 2600T transmitters affects performance of the original device. These effects are shown in: ccuracy Temperature effect Dynamic response ccuracy ccuracy is only marginally affected when seal diaphragm stiffness is relevant low compared with sensor stiffness. High stiffness of diaphragm associated with low URL might produce increased errors of linearity, hysteresis and longterm stability and has effect to the behavior of changing process and environment conditions. Temperature effect The S26 system has an effect on temperature performance of the complete transmitter. Errors primarily affect the zero position of units. They are caused by a temperaturedependent change in volume of the fill fluids in the seal system. The change in volume must be absorbed by the seal diaphragm. Depending on the stiffness of the diaphragm, additional pressure may form in the fill fluid, resulting in a zero error. The level of error depends on the stiffness of the seal diaphragm and the thermal expansion coefficient of the fill fluid. Dynamic response pplication of S26 seal to transmitters increases the original time response. The amount of the increase depends on the number of elements and condition of the instrument as follows: transmitter sensor range fill fluid viscosity of the S26 system applied ambient and process temperature capillary length The delay introduced by the seal may be added to the time constant of the associated transmitter. To obtain the best application solution: choose the sensor code with URL closest to the application SPN. select largest diameter diaphragm seal related to URL. keep the capillary length as short as possible Use fluids with as low as possible viscosity and minimal thermal expansion In vacuum applications, mount the transmitter primary 30 cm / 12 inches or more below the lower seal connection. 3
4 2600T Series Pressure Transmitter S261 SS/S261EN Rev Ordering information The transmitter and each seal system are each identified by a product code number. The code numbers are listed on the type plate of the transmitter, and each character stands for a special product feature. Refer to ordering information for a detailed explanation of the product code numbers. typical example of the product code is as follows: Transmitter product code: 261GRR21_L1 B2 Seal System Product Code: S261WHBEFSCS If remote seal applications not described in this data sheet are required, custom applications are available. Please allow BB to check the existing options in this case by providing the application as well as process and ambient temperature. The following table shows the types of standard seals described in this data sheet. BB can also work with you to develop a special remote seal for applications requiring individual solutions. Please contact your local BB office or representative for additional information. 1.3 Fill fluid properties (Table ) Filling fluids (applications) ID Density at 20 C in kg/m 3 Thermal expansion (x10 /K) Process temperature Silicone oil IL , C (22 2 F) Fluorocarbon G , C ( F) High temperature oil SH , C (1 707 F) White oil (FD) WB 9 7, C ( F) Silicone oil for vacuumtight design White oil (FD) for vacuumproof design ILV , C (22 2 F) WBV 9 7, C ( F) 20 C (6 F) 100 C (212 F) Pressure in kpa abs. 150 C (302 F) 200 C (392 F) 250 C (2 F) > 0,5 > 0,5 > 1,5 > 11 > 100 > 0,3 > 3,5 > 32,5 375 C (707 F) > 0,07 > 0,07 > 0,07 > 0,07 > 1,6 > 100 > 50 > 100 > 100 > 100 > 100 > 0,07 > 0,07 > 0,5 >,5 > 3,5 > 0,5 > 2,5 > 5 > 100 Important Seals with diaphragm made of Tantalum should not be used with temperatures more than 220 C. Seals dimensions on the following pages are in mm (inch).
5 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 2 S261W Model Wafer Remote Seal The wafer remote seal is designed to be clamped between two SME or DIN raised face flanges. The diaphragm side of the seal faces the process flange and a blind backup flange is used on the other side of the seal. Only gaskets manufactured from soft materials may be used with remote seals whose diaphragms and sealing surface is made of tantalum. 2.1 Mounting examples Mounting examples and types of sealing surfaces for DN50 / DN0 or SME 2 inch / ch remote seals Fig. 1 1 Form B2 acc. to EN 1092 (DIN 2526E) Form RF (SME B 16.5) Blind flange 5 SME application 2 Form E acc. to EN 1092 (DIN 2513 V13) 6 DIN application 3 Form D acc. to EN 1092 (DIN 2512 N) 7 DIN application with groove DIN application with tongue 5
6 2600T Series Pressure Transmitter S261 SS/S261EN Rev Seal dimensions Wafer remote seals Flush diaphragm remote seal Extended diaphragm remote seal Fig. 2 1 Blind flange, DIN application 2 Blind flange, SME application Wafer seal dimensions Dimensions in mm (inch) Size Sealing surface a Ø d 1 Ø d 2 Ø d 3 Ø d EN 1092_B2 (DIN 2526E) EN 1092_E (DIN 2513V13) EN 1092_D (DIN 2512N) 2 in Form RF (SME B 16.5 / CL ) DN 0 DN 0 DN 0 EN 1092_B2 (DIN 2526E) EN 1092_E (DIN 2513V13) EN 1092_D (DIN 2512N) Form RF (SME B 16.5 / CL 150) Form RF (SME B 16.5 / CL ) 1 (0.71) 1 (0.71) 1 (0.71) 57 (2.2) 57 (2.2) 57 (2.2) 7 (3.2) 102 (.02) 102 (.02) 102 (.02).3 (1.9).3 (1.9).3 (1.9) Weight in kg (approx.) Flush diaphragm 1 (0.71) 57 (2.2) 102 (.02).3 (1.9) (0.71) 1 (0.71) 1 (0.71) 1 (0.71) 1 (0.71) 7 (3.07) 7 (3.07) 7 (3.07) 7 (3.07) 7 (3.07) 120 (.72) 13 (5.3) 13 (5.3) 13 (5.3) 127 (5) 13 (5.3) 73 (2.7) 73 (2.7) 73 (2.7) 73 (2.7) 73 (2.7) With extended diaphragm
7 2600T Series Pressure Transmitter S261 SS/S261EN Rev Wafer connection dimensions, dimensions in mm (inch) Information on flange design (not supplied) 2 in 2 in 2 in 2 in DN 0 DN 0 DN 0 Flange type Ø k Ø D PN 16 / 0 PN 63 PN psi 300 psi 600 psi 1500 psi PN 16 / 0 PN 63 PN psi 300 psi 600 psi 1500 psi 125 (.92) 135 (5.31) 15 (5.71) (.75) 127 (5) 127 (5) (6.5) 160 (6.3) 170 (6.69) 10 (7.09) 152. (6) 16.3 (6.63) 16.3 (6.63) () 165 (6.5) 10 (7.09) 195 (7.6) 152. (6) (6.5) (6.5) (.5) 200 (7.7) 215 (.6) 230 (9.06) Important Gasket and fixing accessories not supplied. Mounting with capillary tube (7.5) (.25) (.25) (10.5) Number Screws required Ø bore hole 1 (0.71) 22 (0.7) 26 (1.02) 19.1 (0.75) 19.1 (0.75) 19.1 (0.75) 25. (1.00) 1 (0.71) 22 (0.7) 26 (1.02) 19.1 (0.75) 22. (0.) 22. (0.) 31. (1.25) b 1/20 (0.71/0.79) 26 (1.02) 2 (1.1) 19 (0.75) 22.2 (0.7) 25. (1) 3.1 (1.5) 20/2 (0.79/0.9) 2 (1.1) 32 (1.26) 23. (0.9) 2.6 (1.13) 31. (1.25) 7.6 (1.7) 2.3 Specifications Maximum Working Pressure Flush diaphragm wafer remote seals cc. to DIN from PN 10 bar to PN 00 bar cc. to SME from 150 psi to 1500 psi Extended diaphragm remote seal cc. to DIN from PN 10 bar to PN 100 bar cc. to SME from 150 psi to 600 psi but not higher than the load capacity of the flange (not supplied) Vacuum Service Same as fill fluid limits. Refer to table. 2. Temperature effect The following table shows the temperature effect for a 20 K (36 F) change, detailed separately for: a) the remote seal b) the capillary tube per meter c) the transmitter (in addition to the transmitter data sheet) when filling IC silicone oil and stainless steel diaphragm materials. When using a different filling than silicone oil, the errors can be multiplied by the quotient of thermal expansion coefficient of actual filling divided by the thermal expansion coefficient of silicone oil (filling X / silicone oil). (See table Fill fluid properties.) Process Temperature Limits Same as fill fluid limits. Refer to table. 220 C (2 F) for tantalum diaphragm. 150 C (302 F) for use with FEP antistick coating. S261W Wafer remote seal connected to 261GR/R dditional effect for each 20 K (36 F) temperature change Size System (sensor) error Capillary error per meter Seal error kpa mbar in H 2 O kpa mbar in H 2 O kpa mbar in H 2 O Flush diaphragm 2 in / Flush diaphragm / DN Extended diaphragm 2 in / Extended diaphragm / DN
8 2600T Series Pressure Transmitter S261 SS/S261EN Rev Ordering information Main Code Variant S261W Wafer Remote Seal, / DN 0 / 2 in. /. S261W X X X X X X X X Transmitter Side of Connection High side H Size / Pressure Rating 2 in. / Without extension SME CL CL 1500, with extension SME CL CL 600 B. / Without or with extension SME CL 150 N. / Without extension SME CL CL 1500, with extension SME CL CL 600 C / Without extension PN PN 00, with extension PN PN 100 E DN 0 / Without extension PN PN 00, with extension PN PN 100 F Mounting Flange Material / Seat Finish Stainless Steel (1.01) / Form RF (SME B 16.5) 1) E Stainless Steel (1.01) / EN 1092 B2 (DIN 2526 Form E) (PN PN 00) 2) S Stainless Steel (1.01) / EN 1092 E (DIN 2513 V13) (PN PN 100) 2) M Stainless Steel (1.01) / EN 1092 D (DIN 2512 N) (PN PN 160) 2) N Extension Length / Material Flush F 50 mm (2 in.) / ISI 316L SST (1.0) 1 50 mm (2 in.) / Hastelloy C mm ( in.) / ISI 316L SST (1.0) mm ( in.) / Hastelloy C mm (6 in.) / ISI 316L SST (1.0) mm (6 in.) / Hastelloy C276 6 Diaphragm Material ISI 316L SST (1.35), NCE 3) S Hastelloy C276, NCE ) H Tantalum, NCE 5) T ISI 316L SST (1.35) with FEP antistick coating, NCE 5) 1 Hastelloy C276 with FEP antistick coating, NCE 5) 2 Capillary Protection ISI 30 SST (1.301) armour ISI 30 SST (1.301) armour with PVC protective cover 6) B Capillary Length 1 m (3 ft) 2 m (7 ft) C m (13 ft) G 6 m (20 ft) L m (27 ft) Q 11 m (37 ft) W 16 m (53 ft) V Special Length between 1 m and 16 m (dditional cost: 21.0 Euro per m) Z Fill Fluid Silicone oil S Silicone oil for high temperatures, max. 375 C H White oil (FD approved) 7) W Inert fluid ) N Silicone oil for vacuum applications L White oil (FD approved), for vacuum applications 7) Y 1) Not available with DIN size code E, F 2) Not available with SME size code B, N, C 3) Not available with Extension Length / Material code 2,, 6 ) Not available with Extension Length / Material code 1, 3, 5. Not available with Mounting Flange Material / Seat Finish code N 5) Not available with Extension Length / Material code 1, 2, 3,, 5, 6. Not available with Mounting Flange Material / Seat Finish code N 6) Price per meter 7) Suitable for food applications ) Suitable for oxygen applications
9 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 3 S261F Model Flanged Flush and Extended Diaphragm Remote Seal The flush and extended diaphragm remote seal is designed to connect to SME or DIN flanged pipe fitting. 3.1 Seal dimensions Flush diaphragm remote seals With flush diaphragm With extended diaphragm t b L 50/100/150 (1.97/3.9/5.91) b Ød 2 Ød 1 Øk ØD Ød 2 Ød Øk ØD M00197 Fig Form V13 sealing surface b 3.2 Ød 1 120/7 (.72/3.3) (DN 0/50) M00199 Fig. 9
10 2600T Series Pressure Transmitter S261 SS/S261EN Rev Sealing surface Form RF (SME B 16.5), EN 1092B2 (DIN 2526E), EN 1092D (DIN 2512N) Measurements in mm/inches DN 0 DN 0 DN 0 Size Pressure rating Ø D Ø k PN 16 / 0 PN 63 PN 100 PN 16 / 0 PN 63 PN (6.50) 10 (7.09) 195 (7.6) 200 (7.7) 215 (.6) 230 (9.06) 125 (.92) 135 (5.31) 15(5.71) 160 (6.30) 170 (6.69) 10 (7.09) Extension Ø d,3 (1.9),3 (1.9),3 (1.9) 73 (2.7) 73 (2.7) 73 (2.7) 57 (2.2) 57 (2.2) 57 (2.2) 75 (2.95) 75 (2.95) 75 (2.95) Ø d 1 Ø d (.02) 102 (.02) 102 (.02) 13 (5.3) 13 (5.3) 13 (5.3) DN 100 PN (.66) 210 (.27 9 (3.70) 9 (3.50) 1) 1 (7.0) 2 in 2 in 2 in Class 150 Class 300 Class 600 Class 150 Class 300 Class (6.00) (6.50) (6.50) (7.50) (.25) (.25) (.75) 127 (5.00) 127 (5.00) 152. (6.00) 16.3 (6.63) 16.3 (6.63),3 (1.9),3 (1.9),3 (1.9) 73 (2.7) 73 (2.7) 73 (2.7) 57 (2.2) 57 (2.2) 57 (2.2) 75 (2.95) 75 (2.95) 75 (2.95) 92.1 (3.63) 92.1 (3.63) 92.1 (3.63) 127 (5.00) 127 (5.00) 127 (5.00) in Class (9.06) (7.50) 9 (3.70) 9 (3.50) 15 (6.22) DN 0 DN 0 DN 0 Size Pressure rating t b PN 16 / 0 PN 63 PN 100 PN 16 / 0 PN 63 PN (0.0) 2 (0.0) 2 (0.0) 2 (0.0) 2 (0.0) 2 (0.0) 20 (0.79) 26 (1.02) 2 (1.10) 2 (0.9) 2 (1.10) 32 (1.26) Number Screws required Ø bore hole 1 (0.71) 22 (0.7) 26 (1.02) 1 (0.71) 22 (0.7) 26 (1.02) 3,3,5 5, Flush diaphragm Weight in kg DN 100 PN 16 2 (0.0) 22 (0.7) 1 (0.71) 5,9 6, 2 in 2 in 2 in Class 150 Class 300 Class 600 Class 150 Class 300 Class (0.06) 1.6 (0.06) 6.35 (0.25) 1.6 (0.06) 1.6 (0.06) 6.35 (0.25) 19,1 (0.75) 22, (0.) 25, (1.0) 22,2 (0.7) 2, (1.12) 31, (1.25) 19.1 (0.75) 19.1 (0.75) 19.1 (0.75) 19.1 (0.75) 22. (0.) 22. (0.) in Class (0.06) 2 (0.9) 19.1 (0.75) 7,7,6 1) not available for form V13 sealing surface 5, 6,9 9, 2,3 3,7,5 5,3 7,3 9,1 With extended diaphragm 5,2 6,5 7,5,6 11,1 5, 6, , 10
11 2600T Series Pressure Transmitter S261 SS/S261EN Rev Specifications Maximum Working Pressure DIN PN 16/PN 0: MPa, 0 bar, 50 psi DIN PN 63: 6,3 MPa, 63 bar, 913 psi DIN PN 100: 10 MPa, 100 bar, 150 psi Standard temperature 50 C (122 F); as temperature increases the permissible pressure load capacity decreases acc. to EN Temperature effect The following table shows the temperature effect for a 20 K (36 F) change, detailed separately for: a) the remote seal b) the capillary tube per meter c) the transmitter (in addition to the transmitter data sheet) when filling IC silicone oil and stainless steel diaphragm materials. SME CL 150: 1,59 MPa, 15,9 bar, 230 psi SME CL 300:,1 MPa, 1, bar, 600 psi SME CL 600:,27 MPa, 2,7 bar, 1200 psi Standard temperature 3 C (100 F); as temperature increases the permissible pressure load capacity decreases acc. to SME B16.5 When using a different filling than silicone oil, the errors can be multiplied by the quotient of thermal expansion coefficient of actual filling divided by the thermal expansion coefficient of silicone oil (filling X / silicone oil). (See table Fill fluid properties.) Vacuum Service Same as fill fluid limits. Refer to table. Process Temperature Limits Same as fill fluid limits. Refer to table. 220 C (2 F) for tantalum diaphragm. 150 C (302 F) for use with FEP antistick coating. S261F flanged remote seal, connected to 261GR/R dditional effect for each 20 K (36 F) temperature change Size System (sensor) error Capillary error per meter Seal error kpa mbar in H 2 O kpa mbar in H 2 O kpa mbar in H 2 O Flush diaphragm 2 in / Flush diaphragm / DN Flush diaphragm in / DN Extended diaphragm 2 in / Extended diaphragm Extended diaphragm / DN in / DN
12 2600T Series Pressure Transmitter S261 SS/S261EN Rev Ordering information Main Code Variant S261F Flanged Remote Seal, / DN 0 / DN 100 / 2 in. /. / in. S261F X X X X X X X X 1 : Transmitter Side of Connection High side H 2 : Size / Pressure Rating 2 in. / SME CL in. / SME CL 300 D 2 in. / SME CL 600 G. / SME CL 150 B. / SME CL 300 E. / SME CL 600 H in. / SME CL 150 C // DIN PN 16 / PN 0 M / DIN PN 63 P / DIN PN 100 R DN 0 // DIN PN 16 / PN 0 L DN 0 / DIN PN 63 Q DN 0 / DIN PN 100 S Mounting Flange Material / Seat Finish ISI 316L SST (1.0) / Form RF (SME B 16.5) 1) E ISI 316L SST (1.0) / EN 1092 B2 (DIN 2526 Form E) 2) S ISI 316L SST (1.0) / EN 1092 B1 (DIN 2526 Form D) 3) ISI 316L SST (1.0) / EN 1092 E (DIN 2513 V13) 2) M ISI 316L SST (1.0) / EN 1092 D (DIN 2512 N) 2) N Extension Length / Material Flush F 50 mm (2 in.) / ISI 316L SST (1.0) 1 50 mm (2 in.) / Hastelloy C mm ( in.) / ISI 316L SST (1.0) mm ( in.) / Hastelloy C mm (6 in.) / ISI 316L SST (1.0) mm (6 in.) / Hastelloy C276 6 Diaphragm Material ISI 316L SST (1.35), NCE ) S Hastelloy C276, NCE 5) H Tantal, NCE 6) T ISI 316L SST (1.35) with FEP antistick coating, NCE 6) 1 Hastelloy C276 with FEP antistick coating, NCE 6) 2 Capillary Protection ISI 30 SST (1.301) armour ISI 30 SST (1.301) armour with PVC protective cover 7) B Capillary Length 1 m (3 ft) 2 m (7 ft) C m (13 ft) G 6 m (20 ft) L m (27 ft) Q 11 m (37 ft) W 16 m (53 ft) V Special Length between 1 m and 16 m (dditional cost: 21.0 Euro per m) Z Continued on next page 1) Not available with Size / Pressure Rating code L, M, P, Q, R, S, T 2) Not available with Size / Pressure Rating code, B, C, D, E, G, H, T 3) Only available with Size / Pressure Rating code T ) Not available with Extension Length / Material code 2,, 6 5) Not available with Extension Length / Material code 1, 3, 5. Not available with Mounting Flange Material / Seat Finish code N 6) Not available with Extension Length / Material code 1, 2, 3,, 5, 6. Not available with Mounting Flange Material / Seat Finish code N 7) Price per meter 12
13 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 Main Code Variant S261F Flanged Remote Seal, / DN 0 / DN 100 / 2 in. /. / in. S261F X X X X X X X X Fill Fluid Silicone oil S Silicone oil for high temperatures, max. 375 C H White oil (FD approved) ) W Inert fluid 9) N Silicone oil for vacuum applications L White oil (FD approved), for vacuum applications ) Y ) Suitable for food applications 9) Suitable for oxygen applications 13
14 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 S261M model offline flanged connection remote seal The offline flanged connection remote seals are designed to connect directly to SME or DIN flanged tank nozzle..1 Seal dimensions.1.1 Remote seal with flush diaphragm DN 25/ DN 1 in With internal diaphragm PN 10 / 0 or class 150 / 300 With internal diaphragm PN 63 to 250 or class 600 / Ø95 Ø30 Ød 2 f b b H±1 f 2 DN G2 DN Ød Ød Øk Øk ØD ØD M00200 Fig. 5 1 Optional direct mounting 2 Flexible capillary tube possible.1.2 Process connection acc. to EN Form B1 / DIN 2501 Form D Measurements in mm/inches Weight Size Pressure D k d d 2 b f H G2 in kg DN 25 PN 10/0 115 (.53) 5 (3.35) 6 (2.6) 1 (0.55) 22 (0.7) 2 (0.0) 1,5 DN 25 PN 63/100 PN 160 PN (5.51) 10 (5.51) 150 (5.91) 100 (3.9) 100 (3.9) 105 (.13) 6 (2.6) 6 (2.6) 6 (2.6) 2 (0.9) 2 (1.10) 2 (1.10) 2 (0.0) 2 (0.0) 2 (0.0) 52 (2.05) 52 (2.05) 56 (2.20) x M16 x M16 x M20 3,2 3,6,0.1.3 Process connection acc. to SME B 16.5, RF Measurements in mm/inches Size Pressure D k d d 2 b f H 1 in Class 150 Class in Class 600 Class (.33) 125 (.92) 125 (.92) 150 (5.91) 79,5 (3.13) 9 (3.50) 9 (3.50) 101,5 (.00) 51 (2.00) 51 (2.00) 51 (2.00) 51 (2.00) 16 (0.63) 20 (0.79) 22 (0.7) 22 (0.7) 25 (0.9) 36 (1.2) 2 (0.0) 2 (0.0) 7 (0.2) 7 (0.2) 53 (2.09) 6 (2.52) G2 UNC x 5/ in x 7/ in 1, 1,7 2,3, Weight in kg 1
15 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0.2 Specifications Maximum Working Pressure DIN PN 10/PN 0: MPa, 0 bar, 50 psi DIN PN 63/PN 100: 10 MPa, 100 bar, 150 psi DIN PN 160: 16 MPa, 160 bar, 2320 psi DIN PN 250: 25 MPa, 250 bar, 3625 psi Standard temperature 50 C (122 F); as temperature increases the permissible pressure load capacity decreases acc. to EN Temperature effect The following table shows the temperature effect for a 20 K (36 F) change, detailed separately for: a) the remote seal b) the capillary tube per meter c) the transmitter (in addition to the transmitter data sheet) when filling IC silicone oil and stainless steel diaphragm materials. SME CL 150: SME CL 300: SME CL 600: SME CL 1500: 1,59 MPa, 15,9 bar, 230 psi,1 MPa, 1, bar, 600 psi,27 MPa, 2,7 bar, 1200 psi 20.6 MPa, 206. bar, 3000 psi Standard temperature 3 C (100 F); as temperature increases the permissible pressure load capacity decreases acc. to SME B16.5 Vacuum Service Same as fill fluid limits. Refer to table. Process Temperature Limits Same as fill fluid limits. Refer to table. Same as fill fluid limits but not greater than 250 C (2 F) S261M offline remote seal, connected to 261GR/R dditional effect for each 20 K (36 F) temperature change System (sensor) error Capillary error per meter Seal error Size kpa mbar in H 2 O kpa mbar in H 2 O kpa mbar in H 2 O 1 in / DN
16 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0. Ordering information Main Code Variant S261M OffLine Miniflanged Remote Seal, DN 25 / 1 in. S261M X X X X X X X Transmitter Side of Connection High side H Size / Mounting Flange Rating 1 in. / SME CL in. / SME CL 300 C 1 in. / SME CL 600 E 1 in. / SME CL 1500 K DN 25 // DIN PN 10 / PN 0 H DN 25 // DIN PN 63 / PN 100 L DN 25 / DIN PN 160 T DN 25 / DIN PN 250 V Mounting Flange Material / Seat Finish ISI 316 SST (1.01) / Form RF (SME B 16.5) (NCE) 1) E ISI 316 SST (1.01) / EN 1092 D (DIN 2512 N) (NCE) 2) N ISI 316 SST (1.01) / EN 1092 B1 (DIN 2526 Form D) (NCE) 2) Diaphragm Material ISI 316L SST (1.35), NCE S Capillary Protection ISI 30 SST (1.301) armour ISI 30 SST (1.301) armour with PVC protective cover 3) B Capillary Length 1 m (3 ft) 2 m (7 ft) C m (13 ft) G 6 m (20 ft) L Special Length between 1 m and 16 m (Max. 6 m for S261M. dditional cost: 21.0 Euro per m) ) Z Fill Fluid Silicone oil Silicone oil for vacuum applications S L 1) Not available with Size / Mounting Flange Rating code H, L, T, V 2) Not available with Size / Mounting Flange Rating code, C, E, K 3) Price per meter ) Max. 6 m for S261M 16
17 H 2600T Series Pressure Transmitter S261 SS/S261EN Rev. 0 5 S261J Model Inline Remote Seal (without flanges) 5.1 Seal dimensions Inline Remote Seal (without flanges) 1 2 Ø Mb L D M00201 Fig. 6 1 Flexible capillary tube possible 2 Wrench size, SW Process connection acc. to EN / SME B 16.5 Measurements in mm/inches Size Pressure D L Mb 1 in / DN 25 PN 6 to PN psi to 2500 psi 1 ½ in / DN 0 PN 6 to PN psi to 2500 psi 2 in / PN 6 to PN psi to 2500 psi / DN 0 PN 6 to PN psi to 2500 psi 63 (2.) 60 (2.36) 2,5 (1.12) 1, 5 (3.35) 60 (2.36) 3 (1.69) 2,2 95 (3.7) 60 (2.36) 5,5 (2.15) 2,5 130 (5.12) 60 (2.36) 2,5 (3.25),0 Weight in kg 17
18 2600T Series Pressure Transmitter S261 SS/S261EN Rev Specifications Maximum Working Pressure DINcompliant from PN 6 bar to PN 100 bar (higher pressure stages on request), SMEcompliant from 150 (300) psi to 2500 psi, but not higher than the rating of the mounting flange (not supplied). Vacuum Service Same as fill fluid limits. Refer to table. Process Temperature Limits Same as fill fluid limits. Refer to table. 5.3 Temperature effect The following table shows the temperature effect for a 20 K (36 F) change, detailed separately for: a) the remote seal b) the capillary tube per meter c) the transmitter (in addition to the transmitter data sheet) when filling IC silicone oil and stainless steel diaphragm materials. When using a different filling than silicone oil, the errors can be multiplied by the quotient of thermal expansion coefficient of actual filling divided by the thermal expansion coefficient of silicone oil (filling X / silicone oil). (See table Fill fluid properties.) S261J inline remote seal (without flanges), connected to 261GR/R dditional effect for each 20 K (36 F) temperature change Size System (sensor) error Capillary error per meter Seal error kpa mbar in H 2 O kpa mbar in H 2 O kpa mbar in H 2 O 1 in / DN ½ in / DN in / / DN
19 2600T Series Pressure Transmitter S261 SS/S261EN Rev Ordering information Main Code Variant S261J Inline Remote Seal S261J X X X X X X Transmitter Side of Connection High side H Size DN 25 / SME 1 in. DN 0 / SME 11/2 in. B / SME 2 in. C DN 0 / SME. D Diaphragm Material ISI 316L SST (1.35), NCE R Capillary Protection ISI 30 SST (1.301) armour ISI 30 SST (1.301) armour with PVC protective cover 1) B Capillary Length 1 m (3 ft) 2 m (7 ft) C m (13 ft) G 6 m (20 ft) L m (27 ft) Q 11 m (37 ft) W 16 m (53 ft) V Special Length between 1 m and 16 m (dditional cost: 21.0 Euro per m) Z Fill Fluid Silicone oil S Silicone oil for high temperatures, max. 375 C H White oil (FD approved) 2) W Inert fluid 3) N Silicone oil for vacuum applications L White oil (FD approved), for vacuum applications 2) Y 1) Price per meter 2) Suitable for food applications 3) Suitable for oxygen applications 19
20 Contact us BB Ltd. Process utomation Howard Road, St. Neots Cambridgeshire, PE19 EU UK Tel: + (0) Fax: + (0) BB Inc. Process utomation 125 E. County Line Road Warminster P 197 US Tel: Fax: Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB. Copyright 201 BB ll rights reserved 3KXP600001R1001 SS/S261EN Rev BB utomation Products GmbH Process utomation Schillerstr Minden Germany Tel: Fax: Sales Service
ABB MEASUREMENT & ANALYTICS DATA SHEET. S261 Remote seals with capillary tube
BB MESUREMENT & NYTICS DT SEET S261 Remote seals with capillary tube 2 S261 REMOTE SES WIT CPIRY TUBE SS/S261EN REV. D Measurement made easy Engineered solutions for all applications Wide range of remote
More informationS265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications
Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers
ABB measurement & analytics data sheet JAA, JAF and JAG Pneumatic indicating controllers 2 JA A, JAF an d JAG P N EUMATI C I ndicating cont rollers DS/JAx_DBT_DTE-EN Rev. H Measurement made easy Engineered
More informationPressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters
ABB MEASUREMENT & ANALYTICS WHITE PAPER Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters Remote seals protect transmitters when measuring difficult
More informationSITRANS P measuring instruments for pressure
Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to
More information1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition
Siemens AG 08 Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to use a remote seal. The remote seals
More informationWHITE PAPER Overview of Diaphragm and Chemical Seals
WHITE PAPER Overview of Diaphragm and Chemical Seals WHITE PAPER Overview of Diaphragm and Chemical Seals Introduction A diaphragm or chemical seal is a device comprised of a thin membrane known as a diaphragm,
More information2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor
INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationSpecification sheet. Deltapi N Series Pneumatic Transmitters Model NDD Gauge pressure transmitter with remote diaphragm seal GENERAL CHARACTERISTICS
Specification sheet eltapi N Series Pneumatic Transmitters Model N auge pressure transmitter with remote diaphragm seal ENER HRTERISTIS The blind type pressure transmitter, mod. N, is used to measure a
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationThe benefits of the extended diagnostics feature. Compact, well-proven, and flexible
ABB MEASUREMENT & ANALYTICS TECHNICAL INFORMATION PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature The PositionMaster EDP300
More information9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs
Data sheet DS/9408 EN Rev. M 9408 Series Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling design minimizes operational costs Low maintenance,
More informationABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems
ABB MEASUREMENT & ANALYTICS DATA SHEET 9408 series Dissolved oxygen systems Measurement made easy Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling
More informationModel S26 seals for remote and direct mount. 2600T Series Pressure Transmitters Engineered solutions for all applications
Operating Instruction OI/S26-EN Model S26 seals for remote and direct mount 2600T Series Pressure Transmitters Engineered solutions for all applications About this book This book provides instructions
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationATM/GR. Electronic pressure switches CUSTOMER BENEFITS
Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment
More informationATM - Analog Pressure Transmitter
Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationPositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible
Change from one to two columns Technical Information TI/EDP300_ED-EN Rev. A PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature
More informationDiaphragm Series Pressure Gauge
Diaphragm Series Pressure Gauge Product Overview Diaphragm pressure gauge (chemical seals) is composed of a conventional pressure measuring instrument,a connector and a diaphragm seal. This combination
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationTechnical Data Sheet T 2025
Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationPressure Transmitter P41
SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More information2600T Series Pressure Transmitters Calibration Frequency Determination
Application Description AG/266calib-EN Rev. A 2600T Series Pressure Transmitters Calibration Frequency Determination dl Pressure Measurement Engineered solutions for all applications Mantaining desired
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More information3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy
KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationRosemount 3159 Nuclear Qualified Remote Diaphragm Seal
Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal FOR USE ON ROSEMOUNT 3152, 3153, AND 3154 TRANSMITTERS Qualified per: o IEEE Std 323-1974/1983/2003 o IEEE Std 344-1975/1987/2004 112 Mrad (1.12 MGy)
More informationT 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version
T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version Application Excess pressure valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2
More information2600T Series Pressure Transmitter
Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationSelf-operated Pressure Regulators Type 2405 Pressure Reducing Valve
Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve ANSI version Application Pressure reducing valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2 1) (DN
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationPRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a
PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationkyone for All - Unique Mixproof
. kyone for All - Unique Mixproof Alfa Laval Unique Mixproof Tank Outlet Valve (Unique-TO) Concept The exceptional concept of this mixproof valve is characterized by excellent unmatched flexibility - yet
More informationCombined Pressure / Vacuum Relief Valve KITO VD/o
KITO VD/o DN D H kg* vacuum setting (mbar) pressure DIN ANSI DIN ANSI min max min max** 50 PN 16 2 220 332 351 11 3 50 10 75 80 PN 16 3 260 367 387 145 3 50 10 70 100 PN 16 4 260 368 393 178 3 50 10 80
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationATM/Ex - Analog Pressure Transmitter
Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector
More informationUser guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature
Industrial instrumentation for Pressure and Temperature ENG MI-SEP-ENG_0 10/2011 Copyright Nuova Fima S.p.A. All rights reserved. Any part of this publication should not be reproduced without a written
More informationVESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES
VS Series VESSEL & REACTOR VALVES SPRAY & RINSE VALVES PROCESS VALVES CLEANING VESSELS OR REACTORS WITHOUT OPENING TO ATMOSPHERE Spray & Rinse Valves Code: VRR-VRS Automatic models use an electric or air
More informationModel 1159 Remote Diaphragm Seals Manual
00809-0100-4504 English June 1999 Rev. AB Model 1159 Remote Diaphragm Seals Manual With Model 1152, Model 1153 Series B, D, and F, and Model 1154 Alphaline Nuclear Pressure Transmitters Product Discontinued
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationProcessMaster FEP610 Electromagnetic flowmeter
Change from one to two columns Data Sheet DS/FEP61-EN Rev. A ProcessMaster FEP61 Electromagnetic flowmeter The new flowmeter: The first choice for all industrial standard applications. Measurement made
More informationCoriolisMaster mass flowmeter Diagnostics, verification and proof test
ABB MEASUREMENT & ANALYTICS WHITE PAPER CoriolisMaster mass flowmeter Diagnostics, verification and proof test Automatic in situ verification of accuracy for CoriolisMaster mass flowmeters. By Frank Frenzel
More informationModels NAE Pneumatic differential pressure transmitters with remote diaphragm seals
Operating Instruction OI/NAE-EN Rev. A Models NAE Pneumatic differential pressure transmitters with remote diaphragm seals Deltapi N Series A complete range of pneumatic pressure transmitters INTRODUCTION
More informationRR 16 Commercial & Industrial Regulator
Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations
More information7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationBotlek Studiegroep Badotherm. Solving measurements issues with Diaphragm seals 3 Case Studies
Botlek Studiegroep 9-4-2015 Badotherm Solving measurements issues with Diaphragm seals 3 Case Studies Prepared: 10/04/2015 Badotherm Company Summary Badotherm introduction Family owned company Founded
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationx act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor
Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationElectro-Magnetic Flowmeters Electromagnetic Sensor
Data Sheet (US) Electro-Magnetic Flowmeters Electromagnetic Sensor MagMaster TM Plus MFF Unrivalled, fully traceable flow performance 0.15% accuracy Operable flow range: 1500:1 ensures more precise revenue
More informationModel 261GR for gauge pressure Model 261AR for absolute pressure
Change from one to two columns Data Sheet SS/261GR/AR-EN Rev. 07 Model 261GR for gauge pressure Model 261AR for absolute pressure 2600T series pressu re transmitters Engineered solutions for all applications
More informationABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance
Specifications MagMaster Plus MFF Series Electromagnetic Sensors Unrivalled, fully traceable flow performance 0.15% accuracy Operable flow range: 1500:1 insures more precise revenue measurement superior
More information2600T Series Pressure Transmitters Calibration Frequency Determination. Pressure Measurement Engineered solutions for all applications
Application Description AG/266calib-EN Rev. B 2600T Series Pressure Transmitters Calibration Frequency Determination Pressure Measurement Engineered solutions for all applications Mantaining desired performances
More informationZUERCHER BRCeb/BSCeb Series
/Vacuum Rating Max inlet : 16 bar Max back : 2 Bar Full Vacuum Leak Tight to EN 12266-1:2003 Leakage rate A For T = -10 C to +150 C: Leakage rate A For T = -20 C to -10 C: Leakage rate C Control Parameters
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V1.2) Features Pressure range 0kPa~20kPa 70MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationNew! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin
New! ProFlow Sliding Vane Meters DN 15-5 (½ - 2 ) _ 142 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments ProFlow positive displacement sliding vane type liquid flowmeters are used in continuous
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationLow Pressure Diaphragm Sealed Pressure Gauges (571P & 573P Sereies)
Applications Low pressure measuring Specially designed for chemical, petrochemical, paper and food industry All gaseous and liquid media Corrode, Suspended solid, Viscous or Frozen medium Shock & vibration
More informationSeries 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version
Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationType 4708 Supply Pressure Regulator
Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More information200A Series ELECTRONIC LEVEL TRANSMITTER
MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC
More informationPressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof
deflagration- and endurance burning-proof PROTEGO UB/SF 7 Ø b 4 The set pressure is adjusted with a freeze resistant water-glycol mixture, which assures safe operation under extreme cold weather conditions.
More informationSelf-operated Regulators Accessories Differential Pressure and Flow Regulators
Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application
More informationGas Pressure Regulator RMG 201
Product information serving the gas industry worldwide Application, characteristics, technical data Application application in industrial stations for small flowrate regulating lines in gas pressure regulating
More information2600T Series Pressure Transmitters
Installation manual IM/S264_S364-EN Rev.B 2600T Series Pressure Transmitters Models S264 and S364 Remote Seals for Smart Pressure Transmitters - 1 - ABB The Company We are an established world force in
More informationBourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1
Application For aggressive gaseous and liquid media which are not highly viscous and do not crystallize. Suitable for use in corrosive atmospheres. For measurement in areas subject to high vibration levels
More informationPressure measurement. Pressure gauges
Pressure gauge Pressure measurement There are four types of pressure measurements: Measurement of absolute pressure : Measurements are made with respect to absolute pressure, for example as with atmospheric
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V2.0) Features Pressure range 0kPa~20kPa 100MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION
Application Note Doc. G8108-001 Rev. A - 23-Jul-02 ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION For more information regarding Digiquartz products contact: Paroscientific,
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationMEASURING INSTRUMENTS Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind...
Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind...79 Pressure Gauge TC 50.5, connection below...80 Pressure Gauge TC 50.5, connection
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationPC12K Flush Diaphragm Pressure Sensor with Clamp
PC12K Flush Diaphragm Pressure Sensor with Clamp Features Flush diaphragm with clamp structure High reliability imported pressure chip One-time silicon oil filling technology Compensation board filled
More informationGRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide
GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More informationMEASURING INSTRUMENTS - STRUMENTI PER MISURARE
MEASURING INSTRUMENTS - STRUMENTI PER MISURARE SPECIAL PRESSURE GAUGE MN9 capsule pressure gauges DS 2.5 (63mm) PED 201/68/UE For measurement of low pressure and vacuum, for use on gas and dry air. 2.09.1
More information