Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction
|
|
- Baldric Lynch
- 5 years ago
- Views:
Transcription
1 Technical Note Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction Introduction Soil vapor extraction (SVE) is an easy and low-cost remediation method for removing volatile hydrocarbons, typically petroleum by-products, from contaminated soil and groundwater. Designs of SVE systems vary, but the concept involves: 1) pumping air through the vadose zone to volatilize hydrocarbons to a gas and 2) pumping these vapors through an extraction well. As a result, these gases introduce new pressure fluctuations into an aquifer that affect groundwater elevations (Wong, 1997). Pressure fluctuations caused by SVE systems, in conjunction with barometric pressure fluctuations, pose a unique challenge to accurately measuring groundwater elevations in monitoring wells. By setting up the monitoring well using one of the methods described below, groundwater level fluctuations in monitoring wells can be accurately measured in sealed-well SVE systems. If you are recording vacuum measurements to establish the radius of influence in the vadose zone, check with your regulator to determine the barometric sensor accuracy requirements before you select instruments for your project. Method 1 Absolute Level TROLL and BaroTROLL with Suspension Cable In this method, an absolute Level TROLL Data Logger and a BaroTROLL Data Logger are set up to log data. They are then sealed in the SVE well. The Level TROLL records pressure changes due to water level elevation changes and borehole pressure changes. The BaroTROLL collects borehole pressure changes. The two data sets are merged using Win-Situ Baro Merge Software in order to determine water level elevations in the well. Equipment Required Level TROLL 400 or 700 Data Logger, or Rugged TROLL Data Logger BaroTROLL or Rugged BaroTROLL Data Logger Information subject to change without notice. In-Situ, In-Situ logo, Baro Merge, BaroTROLL, HERMIT, isitu, Pocket-Situ, RDO, RuggedCable, RuggedReader, TROLL, and Win-Situ are trademarks or registered trademarks of In-Situ Inc All rights reserved. Tech Note Rev /2014
2 Suspension cable (2) Twist-lock hanger or Rugged TROLL backshell hanger (2) Direct-connect TROLL Com or docking station, or Rugged TROLL Com Well dock, 2-in. Win-Situ 5 Software Instrument Setup Figure 1.1 Instruments are placed inside a sealed well to collect data during the SVE process using Method Synchronize the internal clocks on the Level TROLL and BaroTROLL devices. 2. Set up a scheduled log for the Level TROLL instrument using Win-Situ 5 Software. For instructions on setting up a scheduled log, consult the Help menu in Win-Situ 5 Software. 3. Set up a scheduled log for the BaroTROLL that is identical in start time to the scheduled log for the Level TROLL. Instrument Deployment 1. Place the Level TROLL instrument into the borehole using a twist-lock hanger and a suspension cable anchored by a well dock. 2. Place the BaroTROLL at the top of the monitoring well (out of the water) to monitor pressure fluctuations during the SVE test. 3. Seal the top of the well during the SVE test. 2
3 Method 1 Advantages The BaroTROLL Data Logger captures the borehole pressure fluctuations over the entire SVE test. Sealing the well is simplified with this method. Method 1 Disadvantages Method 2 Two instruments per monitoring well will increase costs. The field engineer cannot communicate with either data logger during the SVE application. This prevents viewing the well data in real time. The data from the Level TROLL must be post corrected using the BaroTROLL data to reflect the true groundwater elevation. Refer to the In-Situ technical note, Manual Level Mode Correction for Non-Vented Sensors, or use the Win-Situ Baro Merge Software utility. The merged data set has a compounded potential error of two instruments, making it less accurate than Method 2. Vented Level TROLL and TROLL Com with Well Cap In this setup, a gauged (vented) Level TROLL Data Logger, vented cable, and part of the TROLL Com are sealed inside the SVE well using a well cap cable holder. The borehole pressure fluctuations are compensated through the vent tube that runs from the TROLL Com, through the cable, and to the back of the Level TROLL pressure sensor. The vent tube allows the Level TROLL device to capture accurate water level elevations with varying pressure fluctuations within the borehole. The field engineer can also communicate with the Level TROLL to view data, download data, and set up additional logs without the need to post correct the data or unseal the well to retrieve the data. Equipment Required Gauged Level TROLL 500 or 700 Data Logger Cable Connect TROLL Com Communication Device Vented (Poly or Tefzel ) RuggedCable System Well dock, 2-in. Well cap cable holder Desiccant pack Bushings, one 2 x 1.5 in. male and one 2-in. female Win-Situ 5 Software (with PC) or Win-Situ Mobile Software (with RuggedReader Handheld PC) 3
4 Instrument Setup Figure 1.2 Instrument is placed inside a sealed well to collect data during the SVE process using Method 2. The instruments are programmed using a PC and Win-Situ 5 Software or with a RuggedReader Handheld PC and Win-Situ Mobile Software. Figure 1.3 RuggedReader Handheld PC 1. Connect the TROLL Com to the RuggedReader or PC. 2. Synchronize the instrument clock to the computer. 3. Program a data log. Define the parameters to include units of measurement and the logging rate. 4. Disconnect the TROLL Com from the computer. 4
5 Instrument Deployment 1. Thread the well cap cable holder over the USB cable. Attach the rubber stopper. When using the serial TROLL Com, the well cap cable holder components must be separated and individually threaded over the TROLL Com body. They will not fit over the DB9 connector. The gray rubber stopper will fit tightly over the DB9 TROLL Com body. After the components of the well cap cable holder are on the DB9 TROLL Com, reassemble the gray rubber stopper and the bushing. 5
6 2. Connect the instrument and cable, and thread them through the bushings. 3. Connect to the TROLL Com. 4. Orient the service grip on the cable 1ft below the surface connector. 5. Attach the 2-in. well dock, making sure that the cable runs through the well dock. 6. Fold the TROLL Com cable in half and fit the cable and the TROLL Com through the 2-in. well dock as shown below. This will allow the service grip to support the cable on the 2-in. well dock. 6
7 7. Insert the TROLL Com and cable into the well, allowing the TROLL Com cable to run out of the well through the bushings and well cap cable holder. 8. Thread the bushings together. Thread the bottom of the well cap cable holder to the bushing. 9. Epoxy the top 1.25 in. of the 2-in. well to seal the bushing assembly in place. 10. Insert the rubber stopper into the well cap cable holder. Apply vacuum grease to the inside and outside of the rubber stopper to help ensure a tight seal after the cable holder is tightened around the compression fitting. 11. Attach the bushings and the well cap cable holder to a 2-in. well. 7
8 12. Protect the TROLL Com connector from damage by putting a sealed zip-lock bag containing a package of desiccant over the connector. Method 2 Advantages Only one Level TROLL per monitoring well is required. The field engineer can view real-time data during the test and set up or download additional logs without removing equipment from the well. Data does not need to be post corrected for barometric fluctuations. Method 2 Disadvantages The field engineer must precisely follow the setup instructions to deploy the Level TROLL into each monitoring well. The gauged Level TROLL device doesn t capture pressure fluctuations within the borehole during the course of the SVE application. 8
9 Method 3 Absolute Level TROLL and BaroTROLL with Two TROLL Com Devices and Two Well Caps In this method, an absolute Level TROLL Data Logger and a BaroTROLL Data Logger are set up to log data that can also be viewed in real time using two TROLL Com devices. The real-time water level data will not be compensated for barometric pressure when it is viewed during the test. The instruments are sealed in the SVE well using a PVC T fitting and two well cap cable holders. The Level TROLL records pressure changes due to water level elevation changes and borehole pressure changes. The BaroTROLL collects borehole pressure changes. The two data sets are merged using Win-Situ Baro Merge Software in order to determine water level elevations in the well. Equipment Required Level TROLL 400 or 700 Data Logger, or (Rugged TROLL Data Logger) Cable-connect TROLL Com (2), or Rugged TROLL Com (2) Non-vented RuggedCable System (2), or Rugged TROLL Cable System (2) Well dock, 2-in. (2) Well cap cable holder (2) Bushings, one 2 x 1.5 in. male and one 2-in. female PVC T-fitting Win-Situ 5 Software (with PC) or Win-Situ Mobile Software (with RuggedReader Handheld PC) 9
10 Instrument Setup Figure 2.1 Instruments are placed inside a sealed well to collect real-time data during the SVE process using Method Synchronize the internal clocks on the Level TROLL and BaroTROLL devices. 2. Set up a log for the Level TROLL instrument using Win-Situ 5 Software. For instructions on setting up a log, consult the Help menu in Win-Situ 5 Software. 3. Set up a log for the BaroTROLL that is identical in start time to the log for the Level TROLL. Instrument Deployment See the Instrument Deployment section for Method 2. Modify the setup to include a PVC T fitting that will accommodate two TROLL Com devices and two well cap cable holders. Method 3 Advantages The BaroTROLL Data Logger captures the borehole pressure fluctuations over the entire SVE test. The field engineer can access uncompensated real-time data during the SVE test. Method 3 Disadvantages Two instruments, two direct communication cables, and two TROLL Com devices per monitoring well will increase cost. 10
11 Method 4 The data from the Level TROLL must be post corrected using the BaroTROLL data to reflect the true groundwater elevation. Refer to the In-Situ technical note, Manual Level Mode Correction for Non-Vented Sensors, or use the Win-Situ Baro Merge Software utility. The merged data set has a compounded potential error of two instruments, making it less accurate than Method 2. TROLL 9500 with Internal Barometric Sensor, TROLL Com, and Well Cap In this setup, a gauged (vented) TROLL 9500 Data Logger, vented cable, and part of the TROLL Com are sealed inside the SVE well using a well cap cable holder. The borehole pressure fluctuations are compensated through the vent tube that runs from the TROLL Com, through the cable, and to the back of the TROLL 9500 pressure sensor. The vent tube allows the TROLL 9500 to capture accurate water level elevations with varying pressure fluctuations within the borehole. The field engineer can also communicate with the TROLL 9500 to view data, download data, and set up additional logs without the need to post correct the data. Additionally, the TROLL 9500 includes an internal barometric sensor that can measure the pressure inside the borehole. Keep in mind that the barometric measurement is not needed to compensate level measurements because the level sensor is vented to the atmosphere. The TROLL 9500 Instrument includes an optical dissolved oxygen sensor that is necessary for air sparging with SVE. Consult an In-Situ Inc. representative for more information. Equipment Required Gauged TROLL 9500 Instrument Cable Connect TROLL Com Communication Device Vented (Poly or Tefzel) RuggedCable System Well dock, 2-in. Well cap cable holder Desiccant pack Bushings, one 2 x 1.5 in. male and one 2-in. female Win-Situ 5 Software (with PC) or Win-Situ Mobile Software (with RuggedReader Handheld PC) 11
12 Figure 2.2 TROLL 9500 is placed in a sealed well to gather real-time water level and barometric data in Method 4. To set up and deploy the TROLL 9500 follow the Method 2 Instrument Setup and Instrument Deployment steps. Method 4 Advantages Only one instrument per monitoring well is required. The field engineer can view real-time data during the test and set up or download additional logs without removing equipment from the well. Data does not need to be post corrected for barometric pressure fluctuations. The engineer can use the instrument's internal barometric sensor to monitor borehole pressure fluctuations inside the monitoring well independent of water level measurements. Method 4 Disadvantages The TROLL 9500 cannot be used in sub one-inch wells. This option is more expensive than using a vented Level TROLL. 12
13 Optional Non-destructive Installation with PVC Extension and Strain Relief It is optional to install the well cap cable holder in a temporary, non-destructive manner using parts purchased from a hardware store. This configuration includes a well dock to provide strain relief for the TROLL Com cable. It also includes a length of PVC pipe that can be drilled to accommodate connection to a differential pressure gauge if appropriate for the application. This is an example of how you might approach an installation to a flush-mount well, but the configuration has not been extensively tested in. x 2 in. rubber boot and 2 hose clamps 4. Threaded coupler 2 in. female NPT 2. 2 in. schedule 40 PVC 2 in. to 4 in. long 5. 2 in. male NPT to 1.5 in.female 3. Well dock (purchase from In-Situ Inc.) Method Accuracy Comparison Example Example for comparison* Level Sensor 35 ft Usable Depth Method 1 or 3 Non-Vented Level TROLL & Baro TROLL 6. Well cap cable holder with liquid/airtight passthrough assembly (purchase from In-Situ Inc.) Method 2 Vented Level TROLL Method 4 TROLL psia = ± 0.07 ft 15 psig = ± ft 15 psig = ± ft Barometric Sensor ± 0.07 ft NA ± 0.11 ft Water Level Total Accuracy Barometric Pressure Accuracy ± 0.14 ft (The accuracy of the Level and Barometric sensors added together.) ± ft ± ± 0.07 ft NA ± 0.11 ft * All accuracy examples are for the full temperature range of the sensor. ** The example for method 1 and 3 calculations are for the BaroTROLL Instrument. Use of a Rugged BaroTROLL will decrease the accuracy. References Wong, J Design of Remediation Systems, Boca Raton. CRC/Lewis Publishers, Boca Raton, Florida. 13
Gas Pressure Probe. Information Sheet. Total Dissolved Gas
Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved
More informationLevel TROLL OPERATOR S MANUAL. Level TROLL 300 Level TROLL 500 Level TROLL 700 BaroTROLL
Level TROLL OPERATOR S MANUAL Level TROLL 300 Level TROLL 500 Level TROLL 700 BaroTROLL March 2007 Copyright 2005 2007 by In-Situ Inc. All rights reserved. Revision history Beta draft June 10, 2005 (Level
More informationQ2: Which instruments are necessary for monitoring the groundwater level?
Micro-Diver 1. Q: What do Divers actually do? 2. Q: Which instruments are necessary for monitoring the groundwater level? 3. Q: Can I place the Diver close to an electrical pump? 4. Q: How should I install
More informationHOBO U20L Water Level Logger (U20L-0x) Manual
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com HOBO U20L Water Level Logger (U20L-0x) Manual The HOBO U20L Water Level Logger is used for monitoring
More informationHOBO U20 Water Level Logger (U x and U x-Ti) Manual
HOBO U20 Water Level Logger (U20-001-0x and U20-001-0x-Ti) Manual The HOBO U20 Water Level Logger is used for monitoring changing water levels in a wide range of applications including streams, lakes,
More informationWL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination
WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination Warning: Non-vented water level loggers may have readings with errors of up to 250mm due to barometric pressure changes.
More informationOnset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate
Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate Models The Water Level logger is available in the following models: U20-001-01 (30 foot depth) and U20-001-01-Ti
More informationReliable, accurate groundwater Diver dataloggers and software. Diver-Suite
Reliable, accurate groundwater Diver dataloggers and software Diver-Suite SMART MONITORING TECHNOLOGY Diver-Suite*, from Schlumberger Water Services, provides groundwater and environmental professionals
More informationReliable, accurate groundwater Diver dataloggers and software. Diver-Suite
Reliable, accurate groundwater Diver dataloggers and software Diver-Suite SMART MONITORING TECHNOLOGY Diver-Suite* from Schlumberger Water Services provides a robust line of Diver* dataloggers for groundwater
More informationDelaware Geological Survey Open File Report No. 51
Delaware Geological Survey Open File Report No. 51 DELAWARE GEOLOGICAL SURVEY GROUNDWATER MONITORING PROCEDURES PART 1: EQUIPMENT AND PROCEDURES FOR MANUAL AND AUTOMATED FIELD MEASUREMENT OF GROUNDWATER
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More information3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More informationDiver-Suite. Reliable, accurate groundwater Diver dataloggers and software
Diver-Suite Reliable, accurate groundwater Diver dataloggers and software Diver-Suite SMART MONITORING TECHNOLOGY Diver-Suite* from Van Essen Instruments provides a robust line of Diver* dataloggers for
More informationAqua TROLL. Aqua TROLL 100 Aqua TROLL 200
Aqua TROLL Operator s Manual Aqua TROLL 100 Aqua TROLL 200 September 2008 Copyright 2008 by In-Situ Inc. All rights reserved. Revision history released January 2007 rev. 001 March 2007 rev. 002 September
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationDiver-NETZ Wireless Groundwater Monitoring Networks
Diver-NETZ Wireless Groundwater Monitoring Networks Monitor your groundwater without boundaries A COMPLETE WIRELESS GROUNDWATER MONITORING SYSTEM From wireless field data collection and recording, to project
More informationTechnical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured
Seametrics Smart Sensors: Precision Environmental Sensors An ONICON Brand The Barometric Compensation Utility is specifically for the PT2X and LevelSCOUT sensors. It uses barometric data to compensate
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationPreparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable
GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationGas Pressure Sensor (Order Code GPS-BTA)
Gas Pressure Sensor (Order Code GPS-BTA) The Vernier Gas Pressure Sensor is used to monitor pressure changes in gas-law experiments in chemistry and physics, such as Boyle s law (pressure vs. volume) and
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationHOBO MX Water Level Logger (MX2001-0x) Manual
HOBO MX Water Level Logger (MX2001-0x) Manual HOBO MX Water Level Logger Models: MX2001-01 or MX2001-01-Ti (Titanium), 9-meter/30-foot depth) MX2001-02, 30-meter/100-foot depth MX2001-03, 76-meter/250-foot
More informationPrecision digital pressure gauge Model CPG1000
Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service
More informationAppendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation
Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly
More informationDeploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President
Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM)
More informationSeries 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features
Features Pressure ranges from 0 to 5 and 0 to 3000 psi (0 to 400 mbar and 0 to 210 bar) xi and 7250i provide advanced precision of 0.005% of reading provides 0.003% of full scale precision Stability: 0.0075%
More informationP Sounding devices with acoustic and GROUNDWATER LEVEL lable in various cable lengths. The devices are provided with a probe, which is
light signal A sounding device is really just a small tube, closed on 11.03 Sounding devices with acoustic and 11.01 Sounding devices with measuring tapes the thickness of the floating layer. The meter
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationD-OptoLogger Dissolved Oxygen Logger Operation Manual
D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4 Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications...
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationPneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
More informationPANACEA P100 LOW PRESSURE USER MANUAL
Basic Features Stainless steel body with 7/8 outside diameter. Will fit into wells down to 1 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground surface
More informationInstructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems
Corporation Issued: 5/09 P/N: 600104 Rev. 2 Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems The Gas Addition Accessory permits the
More informationWATER LEVEL DATALOGGERS
WATER LEVEL DATALGGERS TD-Diver Superior Long-term Performance The TD-Diver is based on an ingenious and proven concept and is acknowledged as the most reliable instrument for the autonomous measuring
More informationTECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236
Sigma-Aldrich Pure-Pac II System Technical Bulletin AL-236 TECHNICAL BULLETIN Product The Sigma-Aldrich Pure-Pac II packaging/dispensing system provides a convenient method for storing and dispensing laboratory
More informationSomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings
SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.
More informationSERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.
SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationFlow meter. bellow vaporizer. APL valve. Scavenging system
Introductory Lecture Series: The Anesthesia Machine PORNSIRI WANNADILOK Objectives Anesthesia Machine Ventilators Scavenging Systems System Checkout 1 Flow meter ventilator bellow vaporizer Corrugated
More informationTable of Contents Want full page pictures with most important parts labeled in the beginning.
1 Table of Contents Want full page pictures with most important parts labeled in the beginning. Precool Procedures (Perform before cooling down): 1. Check N2 and 4He gas tanks to be sure that there is
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationMethod for HOBO Water Level Logger Deployment and Assessing Hydroperiods on Tidal Marsh Platforms
PARTNERSHIP FOR THE DELAWARE ESTUARY Science Group Method for HOBO Water Level Logger Deployment and Assessing Hydroperiods on Tidal Marsh Platforms Date Prepared: 09/26/2016 Prepared By: LeeAnn Haaf Suggested
More informationRejuvenation Instructions
Rejuvenation Instructions #401 Air Systems UPR This NRI covers the following: Understanding the applications and operation of flow meters. Understand the application and operation of test pressure gauges.
More informationPANACEA P125 USER MANUAL
Basic Features Stainless steel body with 1.125 outside diameter. Will fit into wells down to 1-1/4 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground
More informationSOIL GAS PROBE. In-Ground Radon Detection Accessory for the RAD7. DURRIDGE Hardened Steel Soil Gas Probe AMS Stainless Steel Soil Gas Probe
SOIL GAS PROBE In-Ground Radon Detection Accessory for the RAD7 DURRIDGE Hardened Steel Soil Gas Probe AMS Stainless Steel Soil Gas Probe User Manual WARNING! The Soil Gas Probe, drive rod and pilot rod
More informationIn situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details
Warranty details In situ permeability measurement with the BAT Permeameter Quick Manual u low test BAT Geosystems AB (BAT) warrants all new BAT products against defects in materials and workmanship for
More informationProcess Optical Dissolved Oxygen Probe
Process Optical Dissolved Oxygen Probe Operator s Manual November 2013 0089662 Rev. 007 2008-2013 by In-Situ, Inc. This document contains proprietary information that is protected by copyright. No part
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationRST INSTRUMENTS LTD.
RST INSTRUMENTS LTD. Borehole Packers Instruction Manual Copyright 2016 Ltd. All Rights Reserved Ltd. 11545 Kingston St., Maple Ridge, B.C. Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email:
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationUsing the UltraRAE. Firmware 2.35
Using the UltraRAE Firmware 2.35 Training Agenda UltraRAE features Setting up the UltraRAE Turning on the UltraRAE Idle Operation RAE-Sep Tubes Prepping for a measurement Taking a measurement Alarm modes
More informationEASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:
2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use
More informationSDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual July 2017 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationPrecision Liquid Settlement Array Manual
Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change
More informationDURRIDGE STAINLESS STEEL SOIL GAS PROBE
DURRIDGE STAINLESS STEEL SOIL GAS PROBE CONTENTS 1. Introduction... 3 2. Placement... 3 3. Connection... 4 4 Measurement... 4 4.1 GRAB Protocol... 5 4.2 Continuous Monitoring... 6 4.3 Thoron Protocol...
More informationMASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120
MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 QUICK START GUIDE P/N 6006154, REVISION C MAY 2013 Model 8120 Mask Integrity Tester is patented under U.S. Patent No. 8,312,761. Additional patents are pending.
More information3M Liqui-Cel EXF-10x28 Series Membrane Contactor
Membrane Contactors 3M Liqui-Cel EXF-10x28 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III. Part Orientation
More informationWATER LEVEL DATALOGGERS
WATER LEVEL DATALGGERS TD-Diver Superior Long-term Performance The TD-Diver is based on an ingenious and proven concept and is acknowledged as the most reliable instrument for the autonomous measuring
More informationMulti-Parameter Water Quality TROLL. Multi-Parameter TROLL 9500 WQP-100 OPERATOR S MANUAL
Multi-Parameter Water Quality TROLL Multi-Parameter TROLL 9500 WQP-100 OPERATOR S MANUAL November 2006 Copyright 2001 2006 by In-Situ Inc. All rights reserved. Revision history Beta draft September 23,
More informationSeries Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features
GE Sensing & Inspection Technologies Series 7050 Ruska Digital Pressure Indicator Features Pressure ranges from 0 to 10 inh2o and 0 to 1500 psi (0 to 25 mbar and 0 to 100 bar) Choose from three models:
More informationOPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051
NOT SCALE / IF IN DOUBT ASK* DIVE CALIPER OPERATION MANUAL *THIS INFORMATION IS THE PROPERTY OF ZEBRA-TECH LTD. ALL RIGHTS RESERVED.* *ALL UNITS IN MM/DEGREES UNLESS SPECIF SURFACE F 3.2 Ra UNLESS S Part
More informationTripod Setup Guide (M-TPx)
Items needed: 1/2 inch wrench, mast level (M-MLA), medium size wire cutters, crescent wrench, all-purpose grease, tape measure, tie wraps, redi-mix cement (optional), shovel (optional), sledge hammer (for
More informationADVANCED AIRLINE FILTER INSTRUCTION MANUAL
ADVANCED AIRLINE FILTER INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3!WARNINGS! 5 BASEMOUNT ASSEMBLY 6
More informationPAPR Flow Tester. instructions. part no WARNING
PAPR Flow Tester part no. 488903 instructions WARNING This manual, including warnings and cautions inside, must be carefully read and followed by all persons who use or maintain the product, including
More informationVW Liquid Settlement System VWLSS-200
DATASHEET VW Liquid Settlement System VWLSS-200 The Geosense VWLSS-200 Vibrating Wire Liquid Settlement System is used to monitor settlement or heave in soils and other structures such as embankments,
More informationINSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges
INSTRUCTION MANUAL Lesker Model KJL615TC-K Lesker Model KJL615TC-H Digital Vacuum Gauge/Controller KJL615TC K/H Ranges 1 to 1999 millitorr 1 to 1990 microbar 1 to 199.9 Pascal Standard Features Selectable
More informationPressure is our Business
Pressure is our Business Count on gauges and calibrators that perform Wherever you work Reduce Measurement Error Protect against diminished accuracy from environmental conditions, accidental damage, and
More informationSWI NAPL Recovery. Cemcor Environmental Services. represented by. Contact: Craig Marlow Phone Cell
SWI NAPL Recovery represented by Cemcor Environmental Services Contact: Craig Marlow Phone 419.867.8966 Cell 419.349.7970 Email cemarlow@att.net Physical mechanisms of SWI Injection in the saturated zone
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationINSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS
INSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS Joe Henggeler Extension Agricultural Engineer-Irrigation An inexpensive, yet highly accurate, device to measure the depth to water in
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationD-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA
D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5
More informationMulti-Parameter TROLL 9000 WQP-100 Operator s Manual
Multi-Parameter TROLL 9000 WQP-100 Operator s Manual September 2005 Copyright 2001 2005 by In-Situ Inc. All rights reserved. Revision history initial release May 24, 2002 rev. 001 October 3, 2002 rev.
More information! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible
FEATURES! High Static Accuracy & Repeatability! Welded 316 SS or Titanium Construction! Small Rugged Package! User-Specified Pressure Ranges Available! 1% Computer-Tested, Calibrated and Serialized! Unique
More informationT i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)
RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationExperiment C-6 Gas Solubility
1 Experiment C-6 Gas Solubility Objectives To measure dissolved oxygen in water by using an oxygen sensor. To learn about physical factors that influence oxygen solubility in water. To examine the dissolved
More informationWater Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware
57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water
More informationVOLUMATIC WATER REGULATOR
Introduction The Chore-Time VOLUMATIC regulator is designed to regulate water pressure for Chore-Time Layer and Brood Grow Nipple Watering Systems. There is a model for manual adjustment of the regulator
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%
More informationLab 1c Isentropic Blow-down Process and Discharge Coefficient
058:080 Experimental Engineering Lab 1c Isentropic Blow-down Process and Discharge Coefficient OBJECTIVES - To study the transient discharge of a rigid pressurized tank; To determine the discharge coefficients
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationSDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual October 2007 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
More information750 Cable Cutter INSTRUCTION MANUAL
INSTRUCTION MANUAL 750 Cable Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com
More informationwith O 2 Controller Instruction Manual
14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Hypoxic Cabinets (In-Vivo / In-Vitro) with O 2 Controller Instruction Manual Index Page Warranty 2 Warnings
More informationEASIDEW TRANSMITTER with Current Source Output
EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element
More informationMEGR-1627 Instruction Manual
MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More informationFiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual
Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationPaintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132
Paintball Marker User s Manual 530 South Springbrook Road Newberg, OR 97132 Component Concepts, Inc., 530 South Springbrook Road, Newberg, OR 97132 Phone: (503) 554-8095 Fax: (503) 554-9370 www.phantomonline.com
More information