EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

Size: px
Start display at page:

Download "EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS"

Transcription

1 Chapter 65 EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS Ch.D. Taylor NIOSH/Pittsburgh Research Laboratory Pittsburgh, PA J.A. Zimmer NIOSH/Pittsburgh Research Laboratory Pittsburgh, PA ABSTRACT Past studies with blowing face ventilation systems have shown that using a machine-mounted scrubber and water sprays can reduced methane levels at the face. The current research was conducted to determine how the sprays and scrubber interact to reduce methane levels, and what spray configurations provide the best face ventilation when used with a scrubber. Testing was conducted in a ventilation test gallery designed to simulate a full-scale mine entry. In the entry, a model mining machine, equipped with a simulated dust scrubber and water spray systems, was located at the face of a 6.1 m (20 ft) box cut. Face ventilation was provided by a blowing curtain located 12.2 m (40 ft) from the face. Methane released from a manifold at the face was measured at six locations near the face to compare the ventilation effectiveness of the spray systems while operating with and without the scrubber. Airflow movement across the face was affected by the spray configuration and scrubber operation. Average face concentrations were lowest when directed sprays were used with the scrubber. Varying the direction of the scrubber exhaust affected face methane levels. KEYWORDS Ventilation, water sprays, methane, coal mining, dust scrubber INTRODUCTION Effective face ventilation requires that the intake air delivered to the end of the tubing or brattice reach the face. Studies have shown that often only a small fraction of the intake air actually reaches the face (Thimons, 1999). The amount of air reaching the face usually decreases with increasing tubing or curtain setback distance. Research conducted during the development of extended cut mining methods demonstrated that machine-mounted water sprays and scrubbers could be used to help direct additional intake air to the mining face when setback distances exceeded 6.1 m (20 ft) (Volkwein, 1985). Although designed primarily for dust control, machine-mounted water sprays and scrubbers play an important role in increasing the amount of intake air that reaches an extended cut mining face. A water spray moves air like a small fan. When used with exhaust ventilation, groups of sprays directed 30 toward the return side of the entry create airflow patterns that help clear methane from the face. On sections with blowing ventilation, the large quantities of air moved by machine-mounted dust scrubbers effect face airflow patterns. Tests using scrubbers with both blowing and exhausting ventilation showed that operation of a scrubber always reduces face methane concentrations unless the scrubber exhaust flow interferes with the movement of the intake air toward the face (Taylor, 1996). All mining sections use water sprays for dust control, but most sections with exhaust ventilation do not use scrubbers. Scrubbers and water sprays are used on most sections that have blowing ventilation. Past research to evaluate the effects of scrubber use on face methane levels has been conducted with the spray systems operating. Using a scrubber and sprays together reduced face methane levels for a range of setback distances, scrubber flows, and intake flows (Taylor, 1996). Another study showed that water spray systems, regardless of design, improved methane control when used with scrubbers. However, ventilation improved most when the spray system was directed toward the return side of the face (Volkwein and Wellman, 1989). The current research is a continuation of earlier studies to evaluate how the combined use of scrubbers and water sprays affect face methane levels while using blowing ventilation. Tests were conducted for a range of operating conditions that included multiple drum heights and the use of side and underboom sprays.

2 466 PROCEEDINGS OF THE 7 TH INTERNATIONAL MINE VENTILATION CONGRESS TEST FACILITY Gallery Testing was conducted in the National Institute for Occupational Safety and Health s (NIOSH) Pittsburgh Research Laboratory Ventilation Test Gallery. One side of the L shaped building is designed to model an underground mining entry which is 5 m (16.5 ft) wide by 2.1 m (7 ft) high (Figure 1). An exhaust fan draws approximately 5.9 m 3 /sec (12,500 cfm) of air into the gallery. For these tests a brattice and wood curtain, constructed 0.6 m (2 ft) from the left side of the entry, directed 3.3 m 3 /sec (7,000 cfm) of intake air toward the face. Curtain setback distance for all tests was 12.2 m (40 ft). The return air was pulled from the gallery behind a brattice and wood wall built along the right side of the entry. A 1.2 m wide by 6.1 m long (4 ft by 20 ft) box was built along the right side of the face to simulate an uncut slab of coal. A box cut, rather than a slab cut configuration, was selected because changes in methane levels inby the cutting head are easier to detect in the more confined area of the box cut. The mining machine was equipped with a simulated dust scrubber. A fan mounted in the machine drew air into the two 25 by 36 cm (10 by 14 in.) inlets located on both sides, below and just behind, the machine boom. An orifice plate was placed in the scrubber duct to limit flow to approximately 3.3 m 3 /sec (7,000 cfm) for all tests where the scrubber was operating. Air from the scrubber was exhausted through a 38 by 38 cm (15 by 15 in.) opening at the right rear of the machine. Nine horizontal and 9 vertical louvers, each 4 cm (1.4 in.) wide were located at the exhaust opening (see Figure 2). By adjusting the louver direction, scrubber exhaust could be directed, up or down, right or left, and straight. For all tests of the spray systems and scrubber, the louvers were directed so that the scrubber exhaust was directed straight back the entry toward the return. Tests were also conducted to determine if the direction of the scrubber exhaust had an effect on face methane levels. For these tests exhaust flow direction was varied while using only one spray configuration. Figure 2. Model mining machine at face of box cut Figure 1. Ventilation test gallery Mining Machine A full-scale model mining machine was located at the center of the 3.8 m (12.5 ft) wide box cut face (Figure 2). During testing the cutting head rotated at 40 rpm and the center of the drum was positioned approximately 0.5, 1.0, 1.5 m (20, 40 or 60 in.) above the floor (Figure 3). These locations are referred to as the down, middle, and up drum heights. Figure 3. Drum test heights

3 EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE 467 Water Spray Systems The water spray system included manifolds located on the top, on the side, and under the boom (Figure 4). METHANE RELEASE AND INSTRUMENTATION Methane gas was released into the gallery through four horizontal copper pipes that were drilled on top and bottom with 2 mm (1/16 in.) diameter holes. The pipes were equally spaced horizontally, and located 0.1 m (4 in.) away from the face to provide a relatively uniform release of gas. Locations 1, 2, and 3 are 0.3 m (1 ft) from the roof and face, evenly spaced across the face; Locations 4, 5, and 6 are 1.2 m (4 ft) below. Methane was released at a flow rate of approximately 1,300 lpm (45 cfm). For some tests, however, the gas flow was reduced to prevent concentrations in the gallery from exceeding 2 pct. A vacuum pump was used to draw an air sample at 0.5 lpm (0.02 cfm) from each of the six sampling locations. Each air sample was drawn through 9 m (30 ft) of 0.6 cm (1/4 in.) plastic tubing and passed over an individual catalytic heat of combustion type sensor head. TEST PROCEDURE Figure 4. Spray locations on model mining machine Top spray manifold: Ten BD-3 hollow jet nozzles were mounted approximately 0.3 m (1 ft) apart in each of two 3 m (10 ft) long plastic pipes located on top of the miner boom. The sprays in one pipe were directed straight toward the face. In the other pipe, they were directed 30 to the right. All spray nozzles were approximately 0.75 m (30 in.) from the face. Side spray manifold: Four Vee-jet nozzles were positioned 0.15 m (6 in.) apart in a 0.7 m (28 in.) plastic pipe that was mounted vertically on the left side of the mining machine. The flat spray nozzles were aligned so that the spray pattern was vertical and directed toward the face. Underboom spray manifold: Four BD-3 hollow jet nozzles were positioned 0.15 m (6 in.) apart in a 0.7 m (28 in.) plastic pipe that was attached to the underside of the cutting boom. The nozzles were mounted so that they were directed toward the face. Water flow and pressure: A centrifugal pump was used to provide the desired water pressure which was measured with a gauge mounted near the front of the model mining machine. Flows and pressures varied depending on the number of operating sprays. For all tests using water sprays, pressures were maintained between 758 and 896 kpa (110 and 130 psi) and the flow was allowed to vary depending on the number of sprays operating. Pressure at the gauge was adjusted by redirecting part of the water flow at the pump. Prior to the start of each test the desired operating conditions were set. Next, methane gas was introduced into the gallery for 5 min to allow the gas and air to mix. After the mixture reached a relatively steady state concentration, data was collected at each location for 5 minutes. Data from each methanometer was down-loaded every two seconds to a personal computer via an analog to digital conversion board. For each of the locations sampled, the average methane concentration for each five minute sampling period was calculated using an electronic spreadsheet file. Most tests were repeated once and the results averaged. RESULTS Tests were conducted with either the 30 or top sprays operating and the scrubber on. The average face concentrations for the six sampling locations were obtained for each of the three drum heights (Figure 5). For either spray system the highest concentrations were measured when the drum was up and the lowest when the drum was in the middle position. All additional tests to evaluate the water spray systems were conducted with the drum in the up position. Figure 6 shows the concentrations at the left, center, and right side of the face with the drum up and only the straight or 30 top sprays operating. Tests were conducted to evaluate the top spray systems with underboom sprays (Figure 7), side sprays (Figure 8), and underboom and side sprays together (Figure 9). With the addition of side and/or underboom sprays, methane concentrations decreased or remained about the same except:

4 468 PROCEEDINGS OF THE 7 TH INTERNATIONAL MINE VENTILATION CONGRESS Figure 5. Effect of drum heights and top mounted sprays on methane levels Figure 8. Using side sprays with the top sprays Figure 6. Effects of top strays at face sampling locations Figure 9. Combined use of underboom and side sprays with top sprays Tests were conducted to determine how changing the direction of the scrubber exhaust would affect face methane concentrations. For these tests the top 30, side, and underboom sprays were operating, and the drum was in the middle position. Face methane concentrations were reduced as the scrubber exhaust direction was moved from left to right (Figure 10). Changing the horizontal exhaust flow direction, up and down, had less of an effect on face methane levels. DISCUSSION AND CONCLUSION Figure 7. Using underboom sprays with the top sprays When using top 30 sprays and underboom sprays methane levels increased on the left side of the face 42 pct (see Figures 7 and 6). When the underboom and side sprays were used with the top 30 sprays, concentrations on the left side were 14 pct less than when only top sprays were used (see Figures 9 and 6). When using top straight sprays with the side sprays methane levels increased 66 pct on the right side of the face (see Figures 8 and 6). When the underboom and side sprays were used with the top straight sprays, concentrations on the right side were about 17 pct less than when only top sprays were used (see Figures 9 and 6). Operation of either water sprays or machine-mounted scrubber affects face airflow patterns. Using smoke tubes, airflow patterns were drawn with the scrubber and sprays on and off (Figure 11). Curtain setback distance was 12.2 m (40 ft) and intake flow quantity was 3.3 m 3 /sec (7,000 cfm). With only the blowing curtain, the ventilation flow created a Figure 8 pattern that moved from the return to the intake side of the face. Operation of either the scrubber or water sprays reversed the direction of the face airflow, resulting in movement from the intake to the return side of the face. Based on observations of the smoke flow, which indicated straighter and better defined flow with the scrubber, more intake air reached the face with the scrubber operating than with the sprays operating. Establishing a face airflow that moves from the intake

5 EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE 469 to return side of the entry is an important factor in reducing face methane levels. Figure 10. Effect of scrubber flow direction on face methane levels Figure 11. Face airflow patterns for (A) no water sprays or scrubber, (B) scrubber only, and (C) water sprays only When both the sprays and scrubber were operating, flow turbulence inby the miner cutting boom made it difficult to observe the direction of the air movement. The distribution of methane measured during testing indicates that flow did move from the intake to the return side of the face, and the use of the top 30 sprays improved that flow direction. In general, the lower the intake air velocity moving toward the face, the greater the effect water sprays will have on face airflow patterns. Sprays have a greater effect on face airflow when exhausting rather than blowing face ventilation is used. With blowing face ventilation, sprays primarily affect face airflow within 1 or 1.2 m (3 or 4 ft) of the face. They can have a significant effect on re-distributing the gas at the face, but the sprays have less effect on moving methane out of the face area. For the conditions tested, which included a uniform release of methane at the face, methane levels were highest when the drum was up and lowest when the drum was in the middle position. In the up position most of the water from the top mounted sprays hit the roof before it could have a significant impact on face airflow. In the middle position most of the spray reached the face and had a greater effect on face airflow. Underboom sprays are often used on mining machines for dust control. The effect of underboom sprays used in combination with top and side sprays was evaluated. When used with the top 30 sprays, underboom sprays created turbulence that interfered with the movement of air across the face. The result was increased methane levels on the left side of the face. Addition of the side sprays directed more air flow to the left side of the face and reduced face methane levels at that location. Using the side sprays only with the top straight sprays increased methane levels on the right side of the face because the top straight sprays are less effective for moving gas out of the face area. Addition of underboom sprays to the top and side sprays increased turbulence enough to reduce methane levels on the right side of the face. The direction of the exhaust flow had an effect on face methane concentrations. Face methane concentrations were highest when the vertical direction of the exhaust flow was toward the left or intake side of the face. Directing the exhaust to the left interfered with and reduced airflow toward the face. Directing scrubber flow to the right or return side of the entry had the least effect on intake flow and methane concentrations were lowest. Changing the horizontal, or up and down direction of the scrubber exhaust flow had less of an effect on face methane levels, although the gas concentrations were lower when the exhaust was directed downward. Scrubber exhaust should be directed so that it has the least effect on intake air moving toward the face. If the exhaust velocity over any worker is too high, the flow can be directed downward. The conditions tested were designed to simulate face ventilation during mining of a box cut using blowing ventilation. Methane concentrations measured in an operating mine will vary depending on the actual operating conditions and the methane liberation rate in the face area. The results obtained provide guidelines for selection and use of water spray systems for use in improving face airflow and reducing methane concentrations at the face. The guidelines are designed to reduce methane in the face area using water sprays and scrubbers, but will not necessarily reduce dust generated at the face by the mining operation. Water sprays increase turbulent airflow at the face that can improve dilution of methane with available intake air. Turbulent flow can increase dust levels if it creates excessive dust rollback. In some situations the use of a particular water spray system can reduce the collection efficiency of scrubbers by causing the dust to bypass the scrubber inlets. Studies to evaluate the effect of water sprays on dust and water for the same range of operating conditions are planned.

6 470 PROCEEDINGS OF THE 7 TH INTERNATIONAL MINE VENTILATION CONGRESS REFERENCES Taylor CD, Rider JP, and Thimons ED [1996]. Changes in Face Methane Concentrations Using High Capacity Scrubbers with Exhausting and Blowing Ventilation," Proceedings of the SME Annual Meeting, Preprint , Phoenix, AZ, March 11-14, 5 pp Thimons ED, Taylor CD, and Zimmer JA [1999]. Ventilating the Box Cut of a Two-Pass 40 ft Extended Cut, Journal of the Mine Ventilation Society of South Africa, Vol. 52, No.3, July/Sept., pp Volkwein JC, Ruggieri SK, McGlothlin C and Kissell FN [1985]. Exhaust Ventilation of Deep Cuts Using a Continuous-Mining Machine, Bureau of Mines Report of Investigation No. 8992, 16 pp Volkwein JC, Thimons ED, and Hallfinger G [1985]. Extended Advance of Continuous Miner Successfully Ventilated With a Scrubber in a Blowing Section, 2nd U.S. Mine Ventilation Symposium, Reno, NV, Sept 23-25, pp. 741 Volkwein JC, and Wellman TS [1989]. Impact of Water Sprays on Scrubber Ventilation Effectiveness, Bureau of Mines Report of Investigation No. 9259, 12 pp

The principal mechanism for taking medium air velocity measurement is the Anemometer.

The principal mechanism for taking medium air velocity measurement is the Anemometer. 1 Introduction Face Ventilation Stoppings Check Curtains Air Measurements Principals of Airflow Respirable Dust Control Use of Scrubbers Actions for Excessive Methane Rock Dusting Permissibility 2 The

More information

Continuous Miner Ventilation Dust Mitigation Research at UK

Continuous Miner Ventilation Dust Mitigation Research at UK Continuous Miner Ventilation Dust Mitigation Research at UK KY Professional Engineers in Mining Seminar August 26, 2016 Dr. Chad Wedding MSHA New Dust Rule August 1 st, 2014 Revised full shift samplingimmediate

More information

Dust Control Strategies for Continuous Miners in High Mining Areas and Longwall Shearers

Dust Control Strategies for Continuous Miners in High Mining Areas and Longwall Shearers Dust Control Strategies for Continuous Miners in High Mining Areas and Longwall Shearers Harrold Gurley, Dr. Y. P. Chugh, Ahmad MdZami, John Pulliam, Akshat Chandna, Sawyer Schrader, Richard Lyon Mining

More information

Developments in Longwall Ventilation

Developments in Longwall Ventilation 7 Developments in Longwall Ventilation Jiirgen F. Brune, Joseph P. Aman, and Mike Kotch CONSOL Inc., 18 Washington Road, Pittburgh, P A 15241 ABSTRACT Rapid development in longwall mining technology has

More information

CFD modeling of a flooded-bed scrubber concept for a longwall shearer operating in a U.S. coal seam

CFD modeling of a flooded-bed scrubber concept for a longwall shearer operating in a U.S. coal seam CFD modeling of a flooded-bed scrubber concept for a longwall shearer operating in a U.S. coal seam William Chad Wedding*, Thomas Novak, Sampurna Arya, & Ashish Kumar University of Kentucky, Lexington,

More information

SAFE ESCAPE FROM LONGWALL DEVELOPMENT SECTION IN CASE OF A BELT FIRE

SAFE ESCAPE FROM LONGWALL DEVELOPMENT SECTION IN CASE OF A BELT FIRE Abstract When a fire occurs outby a working area, the immediate safe evacuation of miners from the mine should always be the first action during the rescue operation. However, many times, the dedicated

More information

Gas Accumulation Potential & Leak Detection when Converting to Gas

Gas Accumulation Potential & Leak Detection when Converting to Gas Gas Accumulation Potential & Leak Detection when Converting to Gas Coal to Gas / PCUG Conference Chattanooga, TN October 29, 2013 Robert G. Mudry, P.E. Airflow Sciences Corporation Introduction Coal to

More information

PRESSURE BALANCING TECHNIQUES TO CONTROL SPONTANEOUS COMBUSTION

PRESSURE BALANCING TECHNIQUES TO CONTROL SPONTANEOUS COMBUSTION PRESSURE BALANCING TECHNIQUES TO CONTROL SPONTANEOUS COMBUSTION Felipe Calizaya, University of Utah, Salt Lake city, UT Michael G. Nelson, University of Utah, Salt Lake city, UT Christopher Bateman, University

More information

At the end of this lesson, you will be able to do the following:

At the end of this lesson, you will be able to do the following: Liquid-Phase Contacting Scrubbers Goal To familiarize you with the operation, collection efficiency, and major maintenance problems of liquid-phase contacting scrubbers. Objectives At the end of this lesson,

More information

Fan and air movement essentials

Fan and air movement essentials 1 Properties of air For the purposes of this section we will assume that it is air that will be moved by the various types of fans. The air we breathe is made up of a mixture of gasses - nitrogen 78%,

More information

Mine Foreman Training Ventilation Unit 7 Part 2 Ventilating A Mine. Program developed by Wayne Collett Office of Mine Safety & Licensing 2006

Mine Foreman Training Ventilation Unit 7 Part 2 Ventilating A Mine. Program developed by Wayne Collett Office of Mine Safety & Licensing 2006 Mine Foreman Training Ventilation Unit 7 Part 2 Ventilating A Mine Program developed by Wayne Collett Office of Mine Safety & Licensing 2006 1 The purpose of mine ventilation is to provide a safe and productive

More information

Influence of Ventilation Tube Rupture from Fires on Gas Distribution in Tunnel

Influence of Ventilation Tube Rupture from Fires on Gas Distribution in Tunnel Available online at www.sciencedirect.com Procedia Engineering 26 (211) 144 1446 First International Symposium on Mine Safety Science and Engineering Influence of Ventilation Tube Rupture from Fires on

More information

Improved drill shroud capture of respirable dust utilizing air nozzles underneath the drill deck

Improved drill shroud capture of respirable dust utilizing air nozzles underneath the drill deck Improved drill shroud capture of respirable dust utilizing air nozzles underneath the drill deck W.R. Reed and J.D. Potts Mining engineers at the Respiratory Hazards Control Branch, National Institute

More information

Akasison Flow phenomena of a siphonic roof outlet

Akasison Flow phenomena of a siphonic roof outlet Akasison Flow phenomena of a siphonic roof outlet Ir. Marc Buitenhuis MTD Hydraulic research engineer Akatherm BV, Panningen, The Netherlands 06-01-2011 Abstract So far the investigations on siphonic roof

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine Page 1 of 5 Title Design and maintain effective ventilation systems for an underground coal mine Level 5 Credits 20 Purpose People credited with this unit standard are able to, for an underground coal

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Experimental Study of Hydrogen Release Accidents in a Vehicle Garage

Experimental Study of Hydrogen Release Accidents in a Vehicle Garage Experimental Study of Hydrogen Release Accidents in a Vehicle Garage Erik Merilo Mark Groethe James Colton Seiki Chiba Poulter Laboratory SRI International 3rd International Conference on Hydrogen Safety

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network Underground Mining Technology 2017 M Hudyma & Y Potvin (eds) 2017 Australian Centre for Geomechanics, Perth, ISBN 978-0-9924810-7-0 https://papers.acg.uwa.edu.au/p/1710_55_lee/ Evaluation of the optimum

More information

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES A. Marangon, M.N. Carcassi Department of Mechanical, Nuclear and Production Engineering, University of Pisa, Via Largo Lucio Lazzarino,

More information

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS Air Quality Working Group Information Package - Part 7 of 12 December 2018 Doc No. AQWG_5_0.08 Page 1 of 12 Ventilation during Tunnel Construction

More information

NIOSH Information for NAS Committee on Respirable Coal Dust

NIOSH Information for NAS Committee on Respirable Coal Dust NIOSH Information for NAS Committee on Respirable Coal Dust R.J. Matetic, PhD Director, Pittsburgh Mining Research Division NIOSH Mining Program NAS Statement of Task An ad hoc committee will Compare the

More information

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD http:// OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD Anand Kumar S malipatil 1, Anantharaja M.H 2 1,2 Department of Thermal Power Engineering, VTU-RO Gulbarga,

More information

Series 3000 Layout Guidelines

Series 3000 Layout Guidelines Series 3000 Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.

More information

Evaluation of Meter Set Placement and Clearances

Evaluation of Meter Set Placement and Clearances OTD-17/0002 Evaluation of Meter Set Placement and Clearances Prepared by: Gas Technology Institute Des Plaines, Illinois October 2017 FINAL REPORT GTI Project Number 21860 Evaluation of Meter Set Placement

More information

T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation

T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation Published as: T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation Symposium, Dhanbad, India, Oxford and

More information

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 16-1 A flow nozzle is to be used to determine the mass flow rate of air through a 1.5 inch internal diameter pipe. The air in the line upstream of the meters is at 70 F and 95 psig. The barometric pressure

More information

Development of Biomimicry Wind Louver Surface Design

Development of Biomimicry Wind Louver Surface Design International Proceedings of Chemical, Biological and Environmental Engineering, V0l. 93 (2016) DOI: 10.7763/IPCBEE. 2016. V93. 6 Development of Biomimicry Wind Louver Surface Design Jaepil Choi 1, Donghwa

More information

Vacutrans Instructions

Vacutrans Instructions Vacutrans Instructions EMPIRE ABRASIVE EQUIPMENT COMPANY 2101West Cabot Blvd. Langhorne, Pa 19047 215-752-8800, FAX 215-752-9373 Web Site: www.empire-airblast.com ASSEMBLY DETAIL Your Vacutrans unit has

More information

An Experimental Performance Study of Vortex Tube Refrigeration System

An Experimental Performance Study of Vortex Tube Refrigeration System An Experimental Performance Study of Vortex Tube Refrigeration System Sankar Ram T. Department Of Industrial Refrigeration and Cryogenics T. K. M. College of Engineering Karicode, Kollam, Kerala sankarram9@gmail.com

More information

Hours / 100 Marks Seat No.

Hours / 100 Marks Seat No. 17421 21415 3 Hours / 100 Marks Seat No. Instructions : (1) All Questions are compulsory. (2) Answer each next main Question on a new page. (3) Illustrate your answers with neat sketches wherever necessary.

More information

VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM

VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM D Faulkner *, WJ Fisk, DP Sullivan and SM Lee Indoor Environment Dept., Lawrence Berkeley National Lab, Berkeley, CA, USA ABSTRACT

More information

Methods The experiments were carried out in the wind tunnel in the Air physics laboratory at the Engineering Centre Bygholm as shown in figure 1.

Methods The experiments were carried out in the wind tunnel in the Air physics laboratory at the Engineering Centre Bygholm as shown in figure 1. 1 Standardisation of test method for salt spreader: Air flow experiments Report 2: Visualization of airflow patterns by Jan S. Strøm, Consultant Aarhus University, Engineering Centre Bygholm, Test and

More information

Quick Reference Technical Data

Quick Reference Technical Data Bulletin 127C 2 Quick Reference Technical Data For over 100 years, The Spencer Turbine Company has specialized in innovative solutions to air and gas handling problems. Spencer's product line includes

More information

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK FABRICATION AND TESTING OF CLOSE CASING VERTICAL AXIS WIND TURBINE WITH TUNNELLING

More information

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental 6. EXPERIMENTAL METHOD 6.1 Introduction A primary result of the current research effort is the design of an experimental setup that can simulate the interaction of a windmill with a vortex wake and record

More information

CentriFlow Meter Integrated Air Entrainment System

CentriFlow Meter Integrated Air Entrainment System CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:

More information

A computational fluid dynamics model for investigating air flow patterns in underground coal mine sections

A computational fluid dynamics model for investigating air flow patterns in underground coal mine sections A computational fluid dynamics model for investigating air flow patterns in underground coal mine sections by D.D. Ndenguma*, J. Dirker*, and N.D.L. Burger* Synopsis This investigation compares the results

More information

APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES

APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES Peter Botta DPI 03 57611647 0417 501890 APPLICATION OF DRYACIDE DUST FOR THE STRUCTURAL TREATMENT OF GRAIN SILOS, BINS AND GRAIN STORES The application of Dryacide dusts as a structural treatment of grain

More information

Smoke and heat Ventilator Testing

Smoke and heat Ventilator Testing Instituut vir Termodinamika en Meganika Institute for Thermodynamics and Mechanics Smoke and heat Ventilator Testing by CJ Zietsman and GR Smith November 2005 Departement Meganiese Ingenieurswese Privaat

More information

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable.

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable. CITY AND COUNTY OF CARDIFF CODE OF GUIDANCE WORKPLACE VENTILATION All places where people work, be it an office, workshop, school, leisure centre, laboratory, home for the elderly, etc. need to provide

More information

Figure 1. Outer dimensions of the model trucks.

Figure 1. Outer dimensions of the model trucks. 1 Standardisation of test method for salt spreader: Air flow experiments Report 3: Simulations of airflow patterns by Jan S. Strøm, Consultant Aarhus University, Engineering Centre Bygholm, Test and Development

More information

Dust controls and monitoring practices on Australian longwalls

Dust controls and monitoring practices on Australian longwalls University of Wollongong Research Online Faculty of Engineering - Papers (Archive) Faculty of Engineering and Information Sciences 2011 Dust controls and monitoring practices on Australian longwalls Ting

More information

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment The Standard Governing the Storage & Use of Silane: Compressed Gas Association s Publication CGA G-13 2015: Storage

More information

Applied Modelling of Ventilation and Gas Management to Increase Production in a Single Entry Longwall Panel

Applied Modelling of Ventilation and Gas Management to Increase Production in a Single Entry Longwall Panel University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2016 Applied Modelling of Ventilation and Gas Management to Increase Production in a

More information

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL CONTENTS 1. INTENT... 3 2. APPLICATION... 3 3. UNDERGROUND VENTILATION... 3 3.2 Underground Ventilation Officer... 3 3.3 Risk

More information

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question. Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

The System Curve, the Fan Curve, and the Operating Point

The System Curve, the Fan Curve, and the Operating Point The System Curve, the Fan Curve, and the Operating Point AIHA-RMS Sept. 12, 2018 Keith D. Robinson, P.E. Overall Objective To equip an Industrial Hygienist with the skills necessary to document the performance

More information

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations Grzegorz Kubicki, Ph.D. Department of Environmental Engineering, Warsaw University of Technology

More information

CHAPTER 3 : AIR COMPRESSOR

CHAPTER 3 : AIR COMPRESSOR CHAPTER 3 : AIR COMPRESSOR Robotic & Automation Department FACULTY OF MANUFACTURING ENGINEERING, UTeM Learning Objectives Identify types of compressors available Calculate air capacity rating of compressor

More information

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood Statesville, NC Results of AM ASHRAE 11 Laboratory Fume Hood Performance Evaluations Venturi Hood January, 217 Prepared By: Exposure Control Technologies Inc. 231-C East Johnson Street Cary, NC 27513 Phone:

More information

2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 2

2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 2 2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 2 I am, Superintendent of the Bare Bones Coal Co, Inc., Soul Crusher Mine No.1. You are located in the established fresh

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India) IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN(e) : 2278-1684, ISSN(p) : 2320 334X, PP : 45-49 www.iosrjournals.org Modeling, Optimization & Manufacturing of Vortex Tube and Application

More information

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine Page 1 of 5 Title Describe, develop, and maintain basic ventilation systems for an underground coal mine Level 4 Credits 15 Purpose People credited with this unit standard are able to: describe the basic

More information

FOR WASTEWATER APPLICATIONS

FOR WASTEWATER APPLICATIONS Calibration of CENTER PIVOT IRRIGATION SYSTEMS FOR WASTEWATER APPLICATIONS Gary L. Hawkins...Department of Crop and Soil Sciences Wesley Porter...Department of Crop and Soil Sciences Melony Wilson...Department

More information

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Helium Mass Spectrometric Leak Detection In Large Size Process Plants National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17898

More information

LECTURE 1 THE CONTENTS OF THIS LECTURE ARE AS FOLLOWS: 1.0 AIRWAYS CONNECTED IN SERIES AND PARALLEL. 1.1 Airways Connected in Series

LECTURE 1 THE CONTENTS OF THIS LECTURE ARE AS FOLLOWS: 1.0 AIRWAYS CONNECTED IN SERIES AND PARALLEL. 1.1 Airways Connected in Series LECTURE 1 THE CONTENTS OF THIS LECTURE ARE AS FOLLOWS: 1.0 AIRWAYS CONNECTED IN SERIES AND PARALLEL 1.1 Airways Connected in Series 1.2 Airways Connected in Parallel 1.3 Ratio of Resistances of Series

More information

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5 Page 1 of 5 Title Design and maintain effective ventilation systems for a non-coal underground operation Level 5 Credits 20 Purpose People credited with this unit standard are able to: explain the principles

More information

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Available online at   ScienceDirect. Procedia Engineering 112 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 112 (2015 ) 395 399 7 th Asia-Pacific Congress on Sports Technology, APCST 2015 A comparative study of vent designs for effective

More information

Valves. Controllers. Valves Two Types

Valves. Controllers. Valves Two Types Hydraulics Taking the Irritation out of Irrigation My plants are getting irrigated, so I m all set, right? Marcus Duck Academic Advisor, Instructor & Program Coordinator MSU s 2-year Horticulture Programs

More information

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube P P Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube 1 1 2 R.Madhu KumarP P, N.V.V.S.SudheerP PSchool of Mechanical Engineering, R.G.M. College of Engineering

More information

Wind Flow Validation Summary

Wind Flow Validation Summary IBHS Research Center Validation of Wind Capabilities The Insurance Institute for Business & Home Safety (IBHS) Research Center full-scale test facility provides opportunities to simulate natural wind conditions

More information

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR - 9 - AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR O Gorman S., Nuttall R., Purchase A. Parsons Brinckerhoff, Australia ABSTRACT Recent fire tests for tunnels

More information

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY INTERPRETATION IC 62-2001-06 OF ANSI/ASHRAE STANDARD 62-2001 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY REVISION APPROVED: 1/12/2002 Originally issued as interpretation of Standard 62-1989 (IC 62-1989-23)

More information

SECTION 11 VACUUM GRIPPER

SECTION 11 VACUUM GRIPPER VACUUM GRIPPERS SECTION VACUUM GRIPPER EDCO USA. www.edcousa.net : CONTENTS GENERAL INFORMATION ER L-Series Coaxial Venturi Technology : Centralized Systems : Operating Pressure : Discrete Systems :4 Rugged

More information

Free Surface Flow Simulation with ACUSIM in the Water Industry

Free Surface Flow Simulation with ACUSIM in the Water Industry Free Surface Flow Simulation with ACUSIM in the Water Industry Tuan Ta Research Scientist, Innovation, Thames Water Kempton Water Treatment Works, Innovation, Feltham Hill Road, Hanworth, TW13 6XH, UK.

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System JOURNAL ARTICLES BY FLUENT SOFTWARE USERS JA187 Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System Computer simulation has helped NATCO engineers make dramatic improvements

More information

Effect of airflow direction on human perception of draught

Effect of airflow direction on human perception of draught Effect of airflow direction on human perception of draught J. Toftum, G. Zhou, A. Melikov Laboratory of Indoor Environment and Energy Department of Energy Engineering Technical University of Denmark Abstract

More information

21700 Nordhoff St. Chatsworth, CA Phone

21700 Nordhoff St. Chatsworth, CA Phone 21700 Nordhoff St. Chatsworth, CA. 91311 Phone 818.882.2331 DILUTION SYSTEM DILUTION SYSTEM ~ 1 ~ 09 21 07 TABLE OF CONTENTS DEFINITIONS.. 3 INTRODUCTION.. 4 INSTALLATION & SETUP 5 CONVERSION TO PRESSURE

More information

Getting the Most From Your Duct Blaster

Getting the Most From Your Duct Blaster Bob Davis, Ecotope Bruce Manclark, Delta T The Duct Blaster, made by the Energy Conservatory, or similar devices like it, is a durable, versatile calibrated fan/flexible duct assembly that accurately measures

More information

HISTORICAL RESEARCH REPORT Research Report TM/89/

HISTORICAL RESEARCH REPORT Research Report TM/89/ HISTORICAL RESEARCH REPORT Research Report TM/89/03 1989 A study of the formation and control of dust at the ends of highly mechanised longwall faces Bradley A, Aitken M, Garland RP, Nicholl AGMcK, Weston

More information

Understanding Lobe Blowers Roots Blowers. Article written by Technical Team of EVEREST GROUP

Understanding Lobe Blowers Roots Blowers. Article written by Technical Team of EVEREST GROUP Understanding Lobe Blowers Roots Blowers Article written by Technical Team of EVEREST GROUP ompressors and Fans are essentially pumps for gases. Although they differ in construction from liquid handling

More information

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION Aldin Justin 1, Robin James, Shruti Panicker 2,A.N.Subash,Saravana Kumar 1 Assistant Professor,Karunya University, aldinjustin@karunya.edu

More information

FROM THE CLASSICAL FIRE FIGHTING WATER SUPPLY TO STRUCTURE AND SMOKE GAS COOLING TAKING GLEINALMTUNNEL AS AN EXAMPLE; PART II

FROM THE CLASSICAL FIRE FIGHTING WATER SUPPLY TO STRUCTURE AND SMOKE GAS COOLING TAKING GLEINALMTUNNEL AS AN EXAMPLE; PART II - 131 - FROM THE CLASSICAL FIRE FIGHTING WATER SUPPLY TO STRUCTURE AND SMOKE GAS COOLING TAKING GLEINALMTUNNEL AS AN EXAMPLE; PART II Kern H. AQUASYS Technik GmbH, Linz Austria ABSTRACT Traditionally fire

More information

Construction Dewatering

Construction Dewatering Construction Dewatering Introduction The control of groundwater is one of the most common and complicated problems encountered on a construction site. Construction dewatering can become a costly issue

More information

2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 1

2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 1 2012 THE KEMI MINE SAFETY & TRAINING COMPETITION SUPERINTENDENT S STATEMENT DAY 1 Welcome, I am the Superintendent of the Lonesome Creek Mining Co. Twin Shafts Mine. You are located at the fresh air base

More information

CTK Co., Ltd. (Ho-dong) 113, Yejik-ro, Cheoin-gu, Yongin-shi Gyeonggi-do KOREA, REPUBLIC OF Tel: Fax:

CTK Co., Ltd. (Ho-dong) 113, Yejik-ro, Cheoin-gu, Yongin-shi Gyeonggi-do KOREA, REPUBLIC OF Tel: Fax: Page (2) / (14) pages 1. Degrees of protection provided by enclosures (IP code) 1.1 Test standard: KS C IEC 60529:2006 1.2 Arrangement of the IP code IP 6 7 Code letters (International protection) First

More information

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Operating Instructions for Cobra and Lynx Duct Leakage Testers Operating Instructions for Cobra and Lynx Duct Leakage Testers Table of Contents Introduction Introduction... 2 Safety Precautions Safety Precautions.. 2 Prior to Testing System Preparation.. 4 Power Requirements...

More information

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES Test Procedure for DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES TxDOT Designation: Tex-240-F Effective Date: December 2004 1. SCOPE 1.1

More information

VRS Assembly & Operating Instructions

VRS Assembly & Operating Instructions VRS Assembly & Operating Instructions Models VRS-18 Pn #270003 VRS-24 Pn #270006 VRS-30 Pn #270010 Not for use on pressure vessels equipped with Automatic exhaust valve (680 controls) EMPIRE ABRASIVE EQUIPMENT

More information

POWER FLUSH KIT INSTRUCTIONS

POWER FLUSH KIT INSTRUCTIONS 1 GENERAL INFORMATION POWER FLUSH KIT INSTRUCTIONS ACE Power Flush is an ozone-safe solvent engineered specifically for flushing refrigeration and air conditioning systems. Used exactly like the old R-11

More information

Review of Dust Control Strategy Optimisation using Real-time Respirable Dust Monitoring

Review of Dust Control Strategy Optimisation using Real-time Respirable Dust Monitoring Review of Dust Control Strategy Optimisation using Real-time Respirable Dust Monitoring Hsin Wei Wu, Stewart Gillies and Muhammad Usman Khan Abstract Respirable dust is a continuing problem in mines where

More information

Introduction to Pumps

Introduction to Pumps Introduction to Pumps 1 Introduction to Pumps 1.0 INTRODUCTION There are many different types of pump now available for use in pumped fluid systems. A knowledge of these pump types and their performance

More information

4194 Series Differential Pressure Indicating Controllers

4194 Series Differential Pressure Indicating Controllers Product Bulletin 4194 Differential Pressure Controllers 4194 Series Differential Pressure Indicating Controllers The 4194 Series (low pressure) differential pressure indicating controllers (figure 1) show

More information

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE S.Ramamurthy 1, R.Rajendran 1, R. S. Dileep Kumar 2 1 Scientist, Propulsion Division, National Aerospace Laboratories, Bangalore-560017,ramamurthy_srm@yahoo.com

More information

2017 DAY #1 MINE RESCUE PROBLEM

2017 DAY #1 MINE RESCUE PROBLEM 2017 AY #1 MINE RESCUE PROBLEM September 12 th, 2017 Beaver, WV Judges Packet NATIONAL MINE RESCUE CONTEST AY #1-SUPERINTENENT STATEMENT Thank you for answering our call for help and a quick response.

More information

Attitude Instrument Flying and Aerodynamics

Attitude Instrument Flying and Aerodynamics Attitude Instrument Flying and Aerodynamics 2.1 TURNS 1. An airplane requires a sideward force to make it turn. a. When the airplane is banked, lift (which acts perpendicular to the wingspan) acts not

More information

Item 404 Driving Piling

Item 404 Driving Piling Item Driving Piling 1. DESCRIPTION Drive piling. 2. EQUIPMENT 2.1. Driving Equipment. Use power hammers for driving piling with specified bearing resistance. Use power hammers that comply with Table 1.

More information

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES A. M. ElNokaly 1, J. C. Chilton 2 and R. Wilson 1 1 School of the Built Environment, University of Nottingham, Nottingham, NG7 2RD, UK 2 School of Architecture,

More information

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program 1 Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program Jim Meacham, CTG Energetics Agenda 2 In Situ Testing Results Reduced Ventilation after

More information

Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows) Between Levels And Surface

Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows) Between Levels And Surface Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows) Between Levels And Surface Valeriy Popov 1*, Yuriy Filatov 1, Hee Lee 2, and Anatoliy

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212) This guide covers handling and airless spray application of American WeatherStar waterborne single component acrylic elastomeric coatings. These American WeatherStar products require only complete evaporation

More information

ARCA Guidance Note. Guidance on Air Management in Asbestos Enclosures

ARCA Guidance Note. Guidance on Air Management in Asbestos Enclosures Guidance on Air Management in Asbestos Enclosures 1 GUIDANCE ON AIR MANAGEMENT IN ASBESTOS ENCLOSURES 1. BACKGROUND 1.1 This guidance note is intended to clarify expectations with regard to air management,

More information

COATINGS SPRAY GUIDE Urethane 520

COATINGS SPRAY GUIDE Urethane 520 This guide covers handling and airless spray application of AWS URETHANE 520 single component, moisture-cured polyurethane elastomeric coating. Airless spray is an effective method of application particularly

More information