1 RECEIVING PBL AT RIG SITE TITLE: Operating Instructions for -3/4 PBL -3/4 DUAL PORTED PBL BYPASS SYSTEM (Applicable to sizes -1/4 & -1/2 also) OPERATING INSTRUCTIONS 1. On receipt of PBL Bypass Tools at Rig site, the tools should be checked for the following: PBL Serial Numbers located on ID band below Ports on the Main Body. Confirm rig end connections are as required. Confirm Drop Ball Kit matches tool size and number. Shearing pressures for Ball Seat (Deactivation Pressure) and Ports (Unlocking Pressure) are marked on tool and on Tech Sheet included in tool packet. Confirm PBL Activation Ball will drift through entire drill string above PBL Tool. Confirm PBL No-Go will allow passage of any required third party Activation Balls. Drift the drop ball thru PBL prior to connecting BHA. Remove tape covering PBL Ports prior to RIH. 2. The Drop Ball Kit that comes with each tool should contain; 5 x 2 Activation Balls 2 x 1-1/8 Locking Balls 10 x 1-3/8 Steel De-Activation Balls 1 x 2 Dart Ball STATIC TEMPERATURE RATING OF ACTIVATION BALLS Ertalyte Ball (white colour) - 25 deg F (130 deg C) Torlon ball (black colour) & Fast Ball deg F (230 deg C) The PBL will be fully tested & ready to RIH when it arrives at the rig site. A surface test is mandatory prior to RE-RUN of tool; refer to Page-5 for Surface test instructions. ACTIVATION PROCEDURE 1. Prior to activating the tool, Record Pump Pressure Pump Strokes. This will be used as a reference to confirm de-activation of the tool. 2. Calculate the fluid displacement volume and time in the drill string to estimate when the Activation Ball will reach the PBL Bypass Tool. Break drill string at rig floor and drop one (1) 2 Activation Ball. It is recommended to fill the drill string with fluid prior to dropping the Activation Ball. 3. Displace approximately 50% of the drill string volume at normal drilling pump rates then reduce the pump rate that the string pressure is 1,000 psi below the ball shearing pressure until the ball lands on the Seat. In addition please consider: Flow rate should be maximum 400 gpm when ball lands on Seat (200 gpm for Fast Ball and 150 gpm for fast dart). NOTE: Care should be taken when pumping the Activation Ball down as pumping the Activation Ball on Seat at high flow rates and/or pressures may cause the Activation Ball to blow through the Seat. Page 1 of 7
2 TITLE: Operating Instructions for -3/4 PBL The Activation Ball will often seat sooner than the calculated pump strokes. The Activation Ball has an equivalent density of 11.2 PPG (20.9 PPG for Fast Ball) drilling fluid. In the event the ball does get blown through the Seat, as indicated by no change in pump pressure/strokes as recorded in Step 1, drop two (2) 1-3/8 De-activation Balls to ensure the Activation Ball has gone through the Seat. This step must be done prior to dropping another vinyl ball. Repeat the normal tool activation process to re-open the tool. 4. When the Activation Ball lands on Seat, the Sliding Sleeve will shift to its open position against the Spring. NOTE: IT TAKES PSI TO ACTIVATE /OPEN THE TOOL. Fluid will now be diverted through the side Ports. As long as pumping is continuous, fluid will be diverted through the Ports. If pumping is halted, the Sliding Sleeve will shift to the closed position. When pumping resumes, the Sleeve will shift open. A constant, high pump rate should be maintained while the tool is in the open position. If low flow rates, low differential pressures between drill pipe and annulus, bull heading, squeezing or similar low flow operations are required, it is recommended to de-activate the PBL Tool prior to commencing such operations. ACTIVATION DURING TOTAL LOSS In case of a vertical well, drop the Activation Ball and wait until the ball reaches the Seat by way of gravity (chasing the Activation Ball by pumping may cause the Activation Ball to blow through the Seat due to a combination of the suction caused by the loss zone and pumping). In case of a horizontal well or highly deviated well, chase the Activation Ball with as low pumping as possible until it lands on the ball Seat. DE-ACTIVATION PROCEDURE 1. Break the drill string at rig floor and drop 2 x 1-3/8 steel De-activation Balls (It is a good practice to drop the second steel ball 5-10 seconds after dropping the first one) 2. After dropping the steel De-activation Balls, immediately start pumping at 50% of the normal drilling flow rates (300 GPM minimum) and watch for a stand pipe pressure increase. When the steel balls reach the PBL Bypass Tool, they will cut off flow through the Ports creating an immediate pressure increase. It is important to Increase or maintain the same pump rate once a pressure increase is observed. DO NOT slow the pumps down once a pressure increase is observed. Continue to build the pressure rapidly while continuing pumping at high constant pump rates until a pressure decrease is seen. (A pressure increase beyond the ball seat shear pressure rating is often required.) The Activation Ball will blow through the Seat at +/- 10% of stated shear pressure depending upon downhole conditions. A pressure decrease is an indication the Page 2 of 7
3 NOTE: TITLE: Operating Instructions for -3/4 PBL Activation Ball has blown through the Seat into the Ball Catcher. The steel balls will follow into the Ball Catcher. After the Activation Ball shears through the Seat, the Sleeve will move to the closed position. Circulation will now be through the BHA. 3. When pumping is resumed, check that the pressure and strokes are the same as they were prior to activating the PBL Tool (See data recorded in Step 1, above). After tripping out of the hole, the balls must be removed from the Ball Catcher Sub before RIH again. The used Activation Balls should be immediately discarded and NEVER RE-RUN. If required, ensure float valve is in BHA below PBL or finger trap (only for completion operation) has been installed in cage to prevent movement of balls. Consult DSI if situation arises. If the PBL Sub is to be rerun after being activated, it is strongly recommended to de-activate the tool prior to tripping out of the hole to minimize the wear within the tool. EMERGENCY WEIGHTED DARTS WITH VINYL BALLS OR FAST DART (HOLLOW DART) A Weighted Dart inserted in a 2 ertalyte/ torlon ball or a 2 Fast Dart (Hollow Dart) are supplied as part of the kit of operating balls. These Darts are to be utilized only in cases where it is not possible to pump down the Activation Ball. These ball/darts weigh -7 times greater than the standard ball to facilitate quicker activation of the PBL Sub when limited or no circulation is possible. These ball/darts MUST be dropped in direction indicated below down the drill string when activating the tool. It is not recommended to utilize the ball/dart in well bores with angles greater than 55º Weighted Ball/Dart Fast Dart (Hollow Dart) Activation & deactivation procedure is same as the standard ball. Each activation by Fast Dart (Hollow Dart) reduces the total available cycles by one. PLEASE NOTE: 1. With little or no circulation due to partial or full blockage of the bit or BHA, the Fast Dart will descend by gravity in a well bore with a maximum inclination of up to 55 deg. However, if the Fast Dart can be pumped down, it can be possible to get the dart to Page 3 of 7
4 TITLE: Operating Instructions for -3/4 PBL the seat with borehole of up to 90 degrees. In horizontal wells we recommend to use the standard activation ball or the Fast Ball to activate the tool. 2. If Fast Dart (Hollow Dart) is utilized in conditions when circulation is possible, the maximum flow rate is 150 GPM when pumping down Dart. 3. Each activation by Fast Dart (Hollow Dart) reduces the total available cycles by one. PBL OPERATIONAL SEQUENCE Should there be any questions regarding the operational procedures of the PBL tool please contact a DSI representative or visit our website Page 4 of 7
5 TITLE: Operating Instructions for -3/4 PBL MAKE UP and TESTING THE PBL AT THE SURFACE (MANDATORY DURING RE-RUN OF TOOL & RIG CREW FAMILIARIZATION. Optional for initial RIH) 1. Pick up the tool and make up the Main Body to the Ball Catcher Sub. Ensure that the Sleeve is in the closed position by looking through the Port on the side of the tool. Ensure that the Ball Catcher cage in Ball Catcher Sub has the bevelled end facing up and no-go cage facing down. Make-up torque is the same as the rotary shoulder thread connection. (Do not Over Torque). 2. Lower the BHA into the hole ensuring that the Ports are below the rotary table. 3. Drop one (1) x 2 Activation Ball to activate the tool. It is recommended to fill up the drill string with fluid prior to dropping the Activation Ball; make-up Kelly to PBL Tool. 4. Engage the pump slowly and watch for the Sleeve opening and the fluid diverting through the Ports. The Sleeve should function within psi. The Sleeve will return back to its original position when pumping is stopped. 5. Break the Kelly from the PBL Tool and drop 2 x 1-3/8 steel De-Activation Balls into the top of the Tool; make-up Kelly to PBL Tool.. Engage the pump and record the pressure at which the Activation Ball shears through the Ball Seat. BUILD PRESSURE RAPIDLY. This should be plus or minus 10% of the recorded pressure that was sent with the Tool. The shearing pressure varies from 1,00-4,500 psi. Ensure the shear pressure is suitable for the application the tool is planned to be used. 7. With the Activation Ball sheared and the Port closed, keep pumping and lift the tool above the rotary table to visually check the Port is closed. 8. Stop the pumps, pick up string and place in the slips Break the PBL Tool between the Main Body and the Ball Catcher Sub. Back out Kelly/Main Body from the string and retrieve the balls from the Ball Catcher by removing Ball Catcher Cage. Do not under any circumstances re-use the Activation Balls once they have been used in the tool. Reinsert Ball Catcher Cage and make-up Kelly/Main Body and Ball Catcher Sub before RIH. Page 5 of 7
6 TITLE: Operating Instructions for -3/4 PBL PBL SUB - DO s & DON Ts All ID s of the drill string components should be larger than the diameter of the activation ball otherwise the ball could get stuck during the pumping process. If other ball-activated tools are used in the drill string (e.g. ball-activated reamer) please consider the drift of the PBL tool. Remove any mud cleaning filters before dropping the activation or de-activation balls. Be careful that no other objects (cement chunk, glove, part of a drill pipe screen, thread protector, etc.) get inside the drill pipe and land on the seat. These objects could act like an activation ball and improperly open the tool. It is highly recommended to place a filter in the standpipe and drill string to prevent unintended activation of the tool due to junk/debris. If the optional surface test is done, always ensure the PBL tool is fully within drilling fluids to avoid potential ball shattering during de-activation. Large diameter LCM materials can be pumped through the PBL ports. LCM size should not normally exceed 1/3 of port diameter (if in any doubt please call a DSI representative). It is recommended to pump the activation ball with a fluid spacer (normal drilling mud, no LCM included) otherwise LCM may pass the ball during the pumping process before the activation ball lands on the seat and LCM gets access to the sensitive BHA. When LCM has been pumped, it is recommended to clean the drill string (with normal drilling mud, no LCM included) from LCM before dropping the de-activation balls. Never re-use a previously dropped activation ball (vinyl). If the BHA is packed-off and therefore unable to circulate, the PBL tool kit contains a Fast Dart. This can be dropped to reach the seat without pumping (up to 55 degrees) and it may be possible to regain circulation through the PBL by starting the pumps and opening the PBL ports. Once the PBL has been activated, high flow rates can be used with pressures that are much higher than the PBL de-activation pressure. DSI recommends the use of high flow rates to fully make use of the extra cleaning power of the PBL sub or high flow to pump LCM (the deactivation pressure ONLY applies when the steel balls have been dropped to de-activate the tool & cannot be exceeded by high flow rates when the tool is open). If low flow rates, low differential pressure between drill pipe and annulus, bull heading, squeezing or similar low flow operations are required, it is recommended to deactivate the PBL tool before commencing such operations. If the PBL sub is laid down and is planned to be re-run in hole, please jet-wash fully with clean water when first POOH. If required, ensure float valve is in BHA below PBL or finger trap has been installed in cage (for completion operations) to prevent movement of balls. Please fully use the running procedures and the tool service guidelines which are sent with each PBL tool (if in any doubt please call a DSI representative). Page of 7
7 Round about 10, Street 911, Jebel Ali Free Zone, P.O. Box 3057, Dubai, United Arab Emirates Tel.: , Fax: , dsifze@eim.ae, A Schoeller-Bleckmann Company
2-7/8 TRIPLE PORTED PBL BYPASS SYSTEM
RECEIVING PBL AT RIG SITE TITLE: Operating Instructions for 2-7/8 Triple Port PBL 1-10-201 2-7/8 TRIPLE PORTED PBL BYPASS SYSTEM OPERATING INSTRUCTIONS 1. On receipt of PBL Bypass Tools at Rig site, the
More informationMOCS. Multiple Opening Circulation Sub. Fluid Bypass Valve
MOCS Multiple Opening Circulation Sub Fluid Bypass Valve 1 Applications BHA Protection o o Pumping LCM Spotting Acid Work-over and completions o o o Well bore cleanout Fluid displacements Bottoms-up circulation
More informationBridge Plugs, Ball Drop & Caged Ball Plugs For Zone Isolation
Bridge Plugs, Ball Drop & Caged Ball Plugs For Zone Isolation ADVANTAGE composite bridge plug, caged ball and ball drop (flow thru) frac plug provide a means to isolate multiple zones during high pressure
More informationNorth American sealing solutions Bridge Plug Ball Drop Frac Plug Caged Ball Frac Plug
North American sealing solutions Bridge Plug Ball Drop Frac Plug Caged Ball Frac Plug The North American Sealing Solutions composite bridge plug, caged ball and ball drop (flow thru) frac plug provide
More informationDB Bridge Plug. Features. Benefits. Applications
DB Bridge Plug The WELLFIRST Premium Cast Iron Bridge Plug designed to run on electric line. Rated between 2000-10000-psi differential, and 300 F from above and below. Features Field Proven Design Constructed
More information1. The well has been shut in on a kick and the kill operation has not started.
Well Control Methods Day 2 1. The well has been shut in on a kick and the kill operation has not started. Shut in drill pipe pressure Shut in casing pressure 500 psi 700 psi After stabilization, both pressures
More informationFloat Equipment TYPE 925/926
Type 925 Float Collar Plunger Valve Float Equipment For less demanding well conditions, such as shallower depths or lower pressures, Top- Co offers economical float equipment certified to API RP 10F category
More informationOCEAN DRILLING PROGRAM
BIH OCEAN DRILLING PROGRAM www.oceandrilling.org Scientifi c Application Packers A packer is an inflatable rubber element that inflates to seal the annular space between the drill string and the borehole
More informationDAY ONE. 2. Referring to the last question, what mud weight would be required to BALANCE normal formation pressure?
DAY ONE 1. Normal formation pressure gradient is generally assumed to be: A..496 psi/ft B..564 psi/ft C..376 psi/ft D..465 psi/ft 2. Referring to the last question, what mud weight would be required to
More informationMultiple Activated Bypass Tool. P roduct I nf ormation. Landrill oiltools. Version Aug 2017
Multiple Activated Bypass Tool P roduct I nf ormation Landrill oiltools Version 2.1.3 Aug 2017 1 Multiple Activation Bypass Tool 1Bi 1.Brief fintroduction ti The LANDRILL Multiple Activation Bypass Tool
More informationECD Reduction Tool. R. K. Bansal, Brian Grayson, Jim Stanley Control Pressure Drilling & Testing
ECD Reduction Tool R. K. Bansal, Brian Grayson, Jim Stanley Control Pressure Drilling & Testing Drilling Engineering Association, Fourth Quarter Meeting November 20, 2008 1 Presentation outline Description
More informationE NGINEERED C EMENTING S OLUTIONS
DART CATCHER TOOL Blackhawk s Dart Catcher Tool provides indication of the exact location of downhole fluids during inner string cement jobs, cementing squeezes, or balanced cement plugs for temporary/permanent
More informationHydro-Mech Bridge Plug
Manual No: 0620000303 Revision: F Approved By: Quality Engineer Date: 2014-9-9 Hydro-Mech Bridge Plug DESCRIPTION: Map Hydro-Mech Bridge Plug is hydraulically actuated and mechanically set. Compact, with
More informationTAM Single SeT inflatable
TAM Single SeT inflatable ReTRievAble PAckeRS Sets with pressure only Releases with straight pull or rotate Ideal for horizontal applications Sets in casing or open hole Runs on tubing, coiled tubing,
More informationOPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE
Page 1 of 8 OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE Size Series 6.50" 478 Reviewed And Approved By: Signature: Initials: Date: Page 2 of 8 Section OPERATING MANUAL DOUBLE ACTING
More informationfloat equipment OPERATING MANUAL TYPE 505/506 Float Equipment 1. INFORMATION & RECOMMENDATIONS Float Equipment
Contents 1. GENERAL INFORMATION & RECOMMENDATIONS 1 2. INSTALLATION FLOAT EQUIPMENT 2 2.1 PRE-USE FIELD INSPECTION 2 2.2 POSITION FLOAT ON CASING STRING 3 3. RUNNING OF FLOAT EQUIPMENT 3 3.1 CIRCULATION
More informationModel A Sleeve Valve Cement Retainer
Ret. O.D. Model A Sleeve Valve Cement Retainer DIMENSIONAL DATA A B C D E F G H J K L M N P Q R 3.593 3.593 3.500 2.500 3.531 3.531 1.345 3.375.750.437 2.437 2.187 7.062 2.437 5.312 11.685 20.093 3.937
More informationBest Practices - Coiled Tubing Deployed Ball Drop Type Perforating Firing Systems
Best Practices - Coiled Tubing Deployed Ball Drop Type Perforating Firing Systems As a result of a recent job incident utilizing a Ball Drop Type firing system deployed on coiled tubing, the following
More informationIWCF Equipment Sample Questions (Surface Stack)
IWCF Equipment Sample Questions (Surface Stack) 1. During a well control operation 4000 psi was shut in below the middle pipe rams. Ram type BOP data: Model: Cameron U type Rated Working Pressure: 15000
More informationSCORPION HIGH-QUALITY, FULLY COMPOSITE PLUGS
SCORPION HIGH-QUALITY, FULLY COMPOSITE PLUGS A DIFFERENT KIND OF ENERGY COMPANY Nine Energy Service isn t your typical oilfield services company. Our success stems from a culture driven by performance
More informationHydroPull. Extended-Reach Tool. Applications
Extended-Reach Tool HydroPull This tool incorporates a cycling valve that momentarily interrupts the flow to create water-hammer pressure pulses inside coiled or jointed tubing used in horizontal well
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationAir and Gas Drilling
Air and Gas Drilling Air and Gas Drilling It is a technique in which the more common drilling fluids, (water or mud) are replaced by highly compressible Air or Natural gas. But Compressibility makes pressure
More informationWILD WELL CONTROL WARNING SIGNS OF KICKS
WARNING SIGNS OF KICKS Warning Signs of Kicks Learning Objectives You will learn the warning signs that indicate the well may be kicking: Warning signs of kicks False kick indicators You will also learn
More informationStudy Guide IADC WellSharp Driller and Supervisor
Times to Flow Check: Before pulling out of the hole Before pulling BHA into the BOP When bit is pulled into the casing Increase in cuttings at shakers with same ROP On connections Upon abnormal trip tank
More informationOn-Off Connector Skirt
On-Off Connector Skirt Retrievable Packers & Accessories The On-Off Connector Skirt is compact, reliable, fully sealing, J-type tubing disconnect device that automatically engages and releases with a small
More informationType 967 Diamond Broaching Type 968 Sidewinder reamer shoe
Type 965 float collar Type 966 float shoe 1. GENERAL INFORMATION & RECOMMENDATIONS Type 967 Diamond Broaching Type 968 Sidewinder reamer shoe Type 969 Sidewinder reamer shoe Float Equipment Top-Co Float
More informationIWCF Equipment Sample Questions (Combination of Surface and Subsea Stack)
IWCF Equipment Sample Questions (Combination of Surface and Subsea Stack) 1. Given the volumes below, how much hydraulic fluid will be required to carry out the following operations (no safety margin)?
More informationDUO-SQUEEZE H LCM Mixing Tables and Operating Procedures
BAROID DUO-SQUEEZE H LCM Mixing Tables and Operating Procedures Prepared for: Prepared by: Submitted by: Submittal Date: All Customers Sharath Savari, Donald L. Whitfill Halliburton January 2014 1 Copyright
More informationRIH intermediate section casing in Bazian-1 exploration oil well
Energy and Sustainability V 559 RIH intermediate section casing in Bazian-1 exploration oil well A. K. Darwesh Petroleum Engineering Department, Engineering Faculty, Koya University, Kurdistan Abstract
More informationW I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS
PRESSURE BASICS AND CONCEPTS Pressure Basics and Concepts Learning Objectives You will be familiarized with the following basic pressure concepts: Defining pressure Hydrostatic pressure Pressure gradient
More informationRestoring Fluid Flow in Tubing Strings
Restoring Fluid Flow in Tubing Strings Andrew Roth, Product Manager Fike Corporation Fike Hydraulic Tubing Drains (HTD) for use with deep hole drilling tools, downhole devices and other oil and off shore
More informationW I L D W E L L C O N T R O L CIRCULATION & WELL CONTROL
CIRCULATION & WELL CONTROL Learning Objectives You will learn: The importance of pump rates and pressures during well control operations Pressure relationships Basic calculations necessary in well control
More informationDeepwater Horizon Incident Internal Investigation
Not all Information has been verified or corroborated. Subject to review based on additional information or analysis. Deepwater Horizon Incident Internal Investigation 1 Areas of Discussion Investigation
More informationRig Math. Page 1.
Page 1 The Calculator and Main Keyboard Display Numerical 10-key pad used for entering numerical values Trigonometric Functions These keys will be used where wellbore angle is an issue These are the keys
More informationBaraShield -664 LCM Standard Field Application Procedure
BaraShield -664 LCM Standard Field Application Procedure Prepared for: Prepared by: Submitted by: Submittal Date: All Customers Sharath Savari, Donald L. Whitfill Halliburton March 2016 1 Copyright 2011
More informationW I L D W E L L C O N T R O L COMPLICATIONS
COMPLICATIONS Complications Learning Objectives You will learn to detect changes that deviate from established trends. You will learn how to respond to problems such as: Pump problems String problems Hole
More informationHPHT Annular Casing Packer. Obex Annular Casing Packer
HPHT Annular Casing Packer Obex Annular Casing Packer Industry Challenge Casing packer to support second stage cement Reduce hydrostatic pressure on formation Get cement to surface Annular gas migration
More informationPerforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP
MENAPS 2013 Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells Kerry Daly, Global BD Manager- DST TCP MENAPS 13-17 WELL FLOW MANAGEMENT TM Scope/ Contents: MENAPS 13-17 Study
More informationPROPOSED NEW SUB- CODE 1 RIG UP AND TEAR. Possibly Fits into Existing Code. 7/26/2018 Review PROPOSED NEW CODE EXISTING OPERATION
NW NW 1 RIG UP AND TAR 1 no sub-code RIG UP AND TAR DOWN Start: Rig released from previous well, nd: Rig fully rigged up, acceptance tests successfully completed, and signed off. DOWN 1 1 Rig Under Tow
More informationNeoProducts, LLC 1201 Dealers Ave. Harahan, LA Ph:
Please read this entire document. It concerns all 9⅝ Vented Thru-tubing Bridge Plugs Read this document before proceeding to NeoProducts Recommended Best Practices for 9⅝ vented T- TBPs. Whenever running
More informationPasquale Imbò e Marco Pelucchi ENI S.pA;
7th European Gas Well Deliquification Conference Innovative Failsafe Capillary Injection System Resolves Liquid Loading in Gas Well with a Cost- Effective Solution that Maintaining Production and Well-Safety
More informationBorais Petroleum Investment Co. SLOT RECOVERY SERVICE General Procedures
Borais Petroleum Investment Co. SLOT RECOVERY SERVICE General Procedures Slot Recovery Procedures: Slot Recovery Running Procedures 1. Cut And Retrieve Operation: Borais s cut and retrieve equipment: 1.
More informationExtended leak off testing
Extended leak off testing Rev: 1.0 03/01/01 Purpose To ensure minimal operational time and risk exposure to personnel, process, production and equipment. The following extended leak off test procedures
More informationAlong-string pressure, temperature measurements hold revolutionary promise for downhole management
Along-string pressure, temperature measurements hold revolutionary promise for downhole management IT S WIDELY KNOWN that the majority of stuck pipe incidents occur while pulling out of hole. If we can
More informationWorked Questions and Answers
Worked Questions and Answers A Learning Document for prospective Candidates For the Rotary Drilling Well Control Test Programme Copyright, IWCF June 2000 Revision No.1, November 2000 IWCF 2000 page 1 of
More informationPANACEA P200 STAINLESS STEEL USER MANUAL
Basic Features Stainless Steel body with 1.75 outside diameter. Will fit into wells down to 2 (schedule 80). Has an internal chamber volume of 200mL. Maximum depth below ground surface of 3000ft. Other
More informationChapter 5 HORIZONTAL DRILLING
Chapter 5 HORIZONTAL DRILLING Chapter 5 How much money am I about to put on the table for a horizontal well? Did I do sufficient planning? Keys to Successful Horizontal Wells Multi-disciplined teams working
More informationPANACEA P100 LOW PRESSURE USER MANUAL
Basic Features Stainless steel body with 7/8 outside diameter. Will fit into wells down to 1 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground surface
More informationVortexFlow DX (Downhole) Tool Installation Instructions
VortexFlow DX (Downhole) Tool Installation Instructions www.vortextools.com Page 1 of 10 The VortexFLOW tools are based upon Technology that is a result of U.S.A. patents 6,151,751; 6,659,118; 6,749,374;
More informationCased-Hole Logging Environment
Cased-Hole Logging Environment 2 Planning a Production Logging Job Planning is an important part of a production logging job. Frequently these jobs can only be done in safety during daylight. Thus, the
More informationCasing Design. Casing Design. By Dr. Khaled El-shreef
Casing Design By Dr. Khaled El-shreef 1 Casing Design CONTENTS Function of Casing Casing Types & Tools Strength Properties Casing Specification Casing Design 2 1 RUNNING AND CEMENTING CASING Reasons for
More informationDynamic Underbalance (DUB)
Dynamic Underbalance (DUB) Perforating Cam Le Perforating Product Champion Agenda Overview DUB Software Tools Case histories 2011 HALLIBURTON. ALL RIGHTS RESERVED. 2 Dynamic Underbalance Software Dynamic
More informationHydraulic Optimization Worksheet for MS Excel All Versions subsequent to 5.0
Hydraulic Optimization Worksheet for MS Excel All Versions subsequent to 5.0 1. Introduction. 2. Data Input. Header. Bit Information. Mud Information. Casing Program. P.D.M./Turbine. Drill String Design.
More informationBlowout during Workover Operation A case study Narration by: Tarsem Singh & Arvind Jain, OISD
1. Introduction An incident of gas leakage from a well took place during workover operations. Subsequently, the gas caught fire on the fourth day in which twelve persons were injured. Two contract workers,
More informationCoiled Tubing string Fatigue Management in High Pressure Milling Operation- Case Study
Coiled Tubing string Fatigue Management in High Pressure Milling Operation- Case Study Abstract: Paper Presenter: Ebrahim Rabbani 1 e.rabbani@mehranservices.com Ebrahim Rabbani, Danial Davoodi 2, Fatemeh
More informationSUBSEA KILL SHEET EXERCISE No. 5
Subsea Kill Sheet Exercise No. 5 SUBSEA KILL SHEET EXERCISE No. 5 Name: Date: Complete the Subsea vertical kill sheet provided on pages 2 and 3. Then answer questions 1 to 12. Please round calculations
More informationDebris Management Drilling Tools
Debris Management Drilling Tools Protecting BHA components during well construction Remove drilling debris from the wellbore before it creates expensive problems. Debris commonly causes downhole tool failure,
More informationSubsea Safety Systems
Subsea Safety Systems The ELSA-HP has been developed to service the high pressure horizontal tree completion and intervention market. With systems designed and qualified up to 15,000 psi, 250 degf and
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More informationDBML-60/80 Squeeze Tool
DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs
More informationPerforation Techniques in brown fields for Production optimization.
P-085 Perforation Techniques in brown fields for Production optimization. Summary *Prof. Asit Kumar Samadder,UPES Different techniques are adopted for perforation like conventional perforation with casing
More informationBENEDUM (DEVONIAN, GAS) API # UPTON COUNTY, TX DRILLING PERMIT # DAILY REPORTS
11/17/2011 11/18/2011 11/19/2011 AFE dated 11/18/2011 - pull tbg out of hole and make a mill run. Run packer on tbg and attempt to reestablish production from Devonian Formation. MIRU Great Basin Pulling
More informationHANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:
HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state
More informationOIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply
OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions
More informationWellwork Chronological Regulatory Report
Well Name: UNIVERSITY 49 #0808H Field: Lin (Wolfcamp) S/T/R: / / County, State: Location Desc: Operator: Enduring Resources, LLC Project Type: Completion District: Southern Project AFE: DV02151 AFE's Associated:
More informationUniversity 31E 4. Ward County, TX. Rig: Union Drlg Rig 229. AFE: $1,393, DHC: $761, WI: Notes: Workover:
Zone: War-Wink Cherry Canyon TD: 7250' Rig: Union Drlg Rig 229 Status: WOC Spud Date: 1/26/2013 RR Date: 2/12/2013 First Sales: AFE: $1,393,293.00 DHC: $761,963.00 WI: Notes: Date Activity 11/14/2012 11/14/12
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationPANACEA P125 USER MANUAL
Basic Features Stainless steel body with 1.125 outside diameter. Will fit into wells down to 1-1/4 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground
More informationJim McCoy. Tubing Anchor Effect on Pump Fillage. Lynn Rowlan Tony Podio Ken Skinner. Gas Well Deliquification Workshop.
Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Tubing Anchor Effect on Pump Fillage Jim McCoy Jim@echometer.com Lynn Rowlan Tony Podio Ken Skinner Gas Separator Overview Natural
More informationIMPLEMENTATION DSIW-System ELDFISK ALPHA MARS 2011
IMPLEMENTATION DSIW-System ELDFISK ALPHA MARS 2011 Report: Wiping performance Pressure drop-rupture disc function-gas kick circulation Ketil Botnmark, Kjell Mikalsen 20.05.2011 This report resumes the
More informationPumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE
October 21, 2010 Pumping Systems for Landscaping Pumps, Controls and Accessories Mark Snyder, PE Pump Station Design Purpose of Pump Stations Pump stations are designed to boost water pressure from a lower
More informationWELL SCAVENGER. Versatile wellbore clean-up tool for the most demanding operations
WELL SCAVENGER Versatile wellbore clean-up tool for the most demanding operations WELL SCAVENGER: A versatile wellbore cleanup tool for flowrestricted applications The inability to recover wellbore debris
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationSAILTEC, INC CONGER COURT, OSHKOSH, WI USA
OK to make this valve hand tight. Pin Mount Style Integral lies 4-5 Degrees above Horizontal. If you store your Hunter "bow down" you will get air-lock in the Integral. Slot Mount Style Pump Body "Down"
More informationBlue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION
Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationOffshore Managed Pressure Drilling Experiences in Asia Pacific. SPE paper
Offshore Managed Pressure Drilling Experiences in Asia Pacific SPE paper 119875 Authors: Steve Nas, Shaun Toralde, Chad Wuest, SPE, Weatherford Solutions Sdn Bhd, SPE, Weatherford Indonesia SPE, Weatherford
More informationOPERATING INSTRUCTIONS FOR THE MODEL 85B
OPERATING INSTRUCTIONS FOR THE MODEL 85B SAFETY PRECAUTIONS FOR THE MODEL 85B System Under Pressure: Shut off air supply and disconnect air hose before disassembling or disconnecting parts. Flying Debris:
More informationExercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C
Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control
More informationRST INSTRUMENTS LTD.
RST INSTRUMENTS LTD. Borehole Packers Instruction Manual Copyright 2016 Ltd. All Rights Reserved Ltd. 11545 Kingston St., Maple Ridge, B.C. Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email:
More informationHydraulic Punch Drivers
SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in
More informationCOAL SEAM METHANE - EXPLORATION AND PRODUCTION
COAL SEAM METHANE - EXPLORATION AND PRODUCTION Dr Ian Gray, Principal Sigra Pty Ltd, 72 Donaldson Road, Rocklea, Queensland 4106 Australia. Tel +61 7 3216 6344, Fax +61 7 3216 6988, WWW: www.sigra.com.au
More informationSPE MS. Copyright 2015, Society of Petroleum Engineers
SPE-173678-MS Cost Effective Solutions to Achieve Injection Post Toe Valve Failure Cody Trebing, Thru Tubing Solutions; Jeff Whitworth, Thru Tubing Solutions; Alex Beszterda, ConocoPhillips Copyright 2015,
More informationR.K. Bansal, Weatherford; P.A. Bern, BP Exploration; Rick Todd, Weatherford; R.V. Baker, BP America; Tom Bailey, Weatherford
AADE-07-NTCE-69 A Downhole Tool for Reducing ECD R.K. Bansal, Weatherford; P.A. Bern, BP Exploration; Rick Todd, Weatherford; R.V. Baker, BP America; Tom Bailey, Weatherford Copyright 2007, AADE This paper
More informationBP SIT Testing Franks Facility Lafayette
BP SIT Testing Franks Facility Lafayette General Information Status: Franks test well Lafayette La. Rig: Franks Test Rig Casing: 13 3/8, 0 to 4,600 Workstring: 4 ½ IF Brine: Fresh Water Directional: Straight
More informationVB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions
VB-7323 Series 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions Application VB-7323 series three-way diverting valves control hot or chilled water in heating or air conditioning systems.
More informationProper Pump Installation Practices
Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment
More informationBaraBlend -665 LCM Standard Field Application Procedure
BAROID BaraBlend -665 LCM Standard Field Application Procedure Prepared for: Prepared by: Submitted by: Submittal Date: All Customers Sharath Savari, Donald L. Whitfill Halliburton Apr 2016 1 Copyright
More informationInflatable Packers for Grouting 11/10/00
Introduction Inflatable Packers for Grouting 11/10/00 Inflatable packers are frequently used for grout injection in geotechnical applications for structural reinforcement and/or water-proofing of foundations,
More informationOperations planning for optimal hole cleaning
Operations planning for optimal hole cleaning Rev 1.0 14 th March 2004. Technical comments? info@kingdomdrilling.co.uk Page 1 Table of contents Operations planning for optimal hole cleaning... 1 Table
More information4400 TwinHybrid Gas Seal
4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general
More informationPathFinder was awarded a contract to drill a complex steam
Advanced Technologies, Solutions Are Improving Wellbore Construction One case history outlines the challenges of drilling well pairs from a pad in a steam assisted gravity drainage field. PathFinder was
More informationTECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages
TECHNICAL BENEFITS OF CJS / RAISE HSP Technical Advantages The HSP is designed for low- to mid- volume applications at flow rates of 1 cubic meter to 30 c. m per day. The benefits are in the details. The
More informationW I L D W E L L C O N T R O L AIR DRILLING
AIR DRILLING Air Drilling Learning Objectives You will learn the basics of: Air drilling equipment Types of air drilling Differences between mud and air drilling You will learn how to apply well control
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationTrogear Bowsprit Through Hull Installation Manual
Trogear Marine Products, LLC www.trogear.com info@trogear.com 866-616-2978 Trogear Bowsprit Through Hull Installation Manual Congratulations on your purchase of the Trogear Bowsprit which can be installed
More informationPractice Exam IADC WellSharp Driller and Supervisor
Workover & Completion Day 4 1. In a workover operation of a shut in well a Lubricator is being used together with a Wireline BOP / Wireline Valve. Which Barrier is classified as the Primary Barrier? A.
More informationPRODUCTS. PBL circ sub Solutions Wedgetail Roller Reamer WWT Non Rotating Protectors Tercel Oilfield Products BiSN Oil Tools BiSN Laboratory Services
PHONE: PHONE: PHONE: MAIL: WEB: + 47 91 69 29 36 + 47 93 04 90 12 +47 47 71 82 68 POST@QSST.NO WWW.QSST.NO PRODUCTS PBL circ sub Solutions Wedgetail Roller Reamer WWT Non Rotating Protectors Tercel Oilfield
More information1997 Drillers Stuck pipe Handbook
1997 Drillers Stuck pipe Handbook 1997 Guidelines & Drillers Handbook Credits written by Colin Bowes & Ray Procter with graphics by Sedco Forex Project Steering & Review Team Dave Ringrose Dick Lancaster
More information