SHOP WELDED TANKS STANDARD CONNECTIONS

Size: px
Start display at page:

Download "SHOP WELDED TANKS STANDARD CONNECTIONS"

Transcription

1 STEEL WELDED TANKS Tanks are constructed using 3/16 and ¼ inch A36 material. Welding and testing are performed according to API 12F specifications. Shop welded tanks are also available in special sizes and can be constructed to API 650, UL 142, and American Water Works Association specifications. Tanks are primed and painted to customer preference. A variety of protective corrosion control coatings can also be provided. We do offer a variety of tank Thief Hatches for specific customer applications by manufacturers such as Vessel Components, Enardo, Jayco and more. Tank pressure ratings per API 12-F for 12 foot diameter are 16 OZ. 15'6" diameter are rated at 8 OZ. Our Longview TX plant offers API 12 F Monogram tanks when required by customer. Coating for external and internal can be customized per application. 33

2 SHOP WELDED TANKS STANDARD ACCESSORIES 1-24 X 36 EXTENDED NECK CLEANOUT 1-PRESSURE / VACUUM THIEF HATCH 7-THREADED CONNECTIONS 1-DOUBLE SET OF WALKWAY LUGS 1-COAT PRIMER & ENAMEL PAINT OPTIONAL ITEMS 1-FLANGED OR GROOVED CONNECTIONS 1-LARGER AND OR ADDITIONAL CONNECTIONS 1-ROLLING LINES 1-DOWNCOMERS 1-PROTECTIVE COATINGS 1-CUSTOM EXTERIOR PAINT STANDARD CONNECTIONS DESCRIPTION 210 BBL & UNDER 250 BBL & OVER VENT CONNECTION 3 4 FILL CONNECTIONS 3 4 OVERFLOW CONNECTIONS 4 4 PIPELINE CONNECTION 4 4 DRAIN CONNECTION 3 4 GAUGING FORMULA: DIAMETER X DIAMETER X.14 = BBL PER Ft. CAPACITY BBLS DIMINSIONS W X H SHIPPING WEIGHT Lbs X 8 3, X 12 2, X 10 5, X 15 5, X 15 6, X 15 6, X 20 8, X 25 9, X 16 10,500 34

3 GUNBARREL TANKS The gunbarrel is a low maintenance atmospheric settling vessel, it provides an economical method in which to treat oil. Most commonly used downstream of a heater treater or separator, production will enter the flume at the top of the vessel. Solution gas released at this point is vented to storage. The oil and water fall downward through the downcomer pipe and contact a spreader table. Free water falls to the bottom section and exits through a waterleg. The large settling section will allow entrained water to coalesce to form larger droplets that gravity flow to the bottom section and combine with the free water. The clean oil at the top of the settling section will spill over the oil outlet and gravity flow to storage. The gunbarrel will not treat emulsions, the oil and water must both be free liquids also the vessel must be tall enough for the oil and water to gravity flow to storage. 35

4 GUNBARRELS STANDARD ACCESSORIES 1-THIEF HATCH 3-SET 48 SIGHT GLASS WITH GAUGE COCKS 1-INTERNAL FLUME 1-FLANGED GAS BOOT 1-SPREADER TABLE 1-BASE BLOCK WITH 4 & 6 Ft DIAMETER 1-COAT PRIMER AND ENAMEL PAINT INLET VENT GAS BOOT OPTIONAL ACCESSORIES 1-CUSTOM EXTERIOR PAINT 1-PROTECTIVE COATINGS OIL OUTLET FLUME 1-FLANGED OR GROOVED CONNECTION 1- LARGER FLUME & SPREADER TABLE SIZE HEIGHT FROM BTM TO OIL OUTLET INLET VENT DECK EQUL. OIL & WATER OUTLETS MANWAY 4X Dia 6X Dia 8X X 36 10X X 36 10X X 36 12X X 36 12X X 36 SPREADER TABLE GAS WATER OIL WATER OUTLET MANWAY DRAIN RETENTION TIME (Hrs.) = 24 X SETTLING VOLUME BBLS. / DAY WATERLEG HEIGHT = (Wh X SG) + (Oh X SG) Water SG 36

5 Coatings Standard Coatings Global Vessel and Tank offers our customer a wide variety of coating options, however our standard coating is a Exterior DTM Polyurethane Epoxy by Devoe offered in a variety of common industry colors. In the event of our customers wanting an Internal Coating our standard coating is Sherwin Williams Nova Plate UHS. These above combinations have a proven track record in the industry. Coating Options As our customers may require special coatings Global Vessel and Tank can accommodate those needs. Our offering includes but is not limited to the following manufacturers; Devoe Sherwin Williams Carboline Enviroline Corchem PPG Custom coatings are typically performed by our 3rd party providers. We can offer both exterior and Internal coatings to meet our customers exact coating specifications. Customer coatings do require more lead time and are done at an additional cost. Custom coatings by our 3rd party providers do carry a full 1 year warranty against manufacturers defects. Subject to inspection. 37

6 DEFINITIONS ABSORBER TOWER A tower that provides contact between natural gas being processed and a liquid or solid desiccant. ABSORPTION The operation in which one or more components in a gas stream are absorbed into a desiccant. ATMOSPHERIC PRESSURE The pressure exerted on the earth by the earth s atmosphere. A pressure of 14.7 psia is used as a standard. BTU An abbreviation for British Thermal Unit. One BTU is the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit. The heating value of a fuel is measured in BTUs. CONDENSATE The liquid formed by the condensation of a vapor or gas, specifically the hydrocarbon separated from natural gas due to changes in pressure and temperature when the gas is produced from the reservoir. DEHYDRATION The process of removing water from gases or liquids. DESICCANT A substance or material used to remove water and moisture. DEW POINT The temperature at any given pressure, or the pressure at any given temperature, at which liquid initially condenses from a gas or vapor. DEW POINT DEPRESSION The difference between the original dew point temperature of a gas and its dew point temperature after dehydration. DRY GAS Gas whose water content has been reduced by dehydration. GAS-OIL RATIO The ratio of gas to oil produced from a well. GAS PROCESSING The separation of constituents from natural gas for the purpose of making salable products and also for treating the residue gas to meet required specifications. HEAT EXCHANGER A jacket which surrounds a casing or machine element in order to remove, add, or distribute heat in order to control the temperature within a vessel or element. HYDRATE A solid material resulting from the combination of a hydrocarbon with water under pressure. JOULE-THOMSON EFFECT The change in gas temperature, which occurs when the gas is expanded at constant enthalpy from a higher pressure to a lower pressure. The effect for most gases at normal pressure is a cooling of the gas. MCF An abbreviation for one thousand cubic feet of gas. 38

7 MMCF The abbreviation for one million cubic feet of gas. NATURAL GAS Gaseous form of petroleum. Consisting predominately of mixtures of hydrocarbon gases. The most common component is methane. PACKED TOWER A absorption column or tower filled with packing designed to give contact between rising gas and a descending liquid. PIPELINE GAS Gas which meets a transmission company s minimum specifications. RELIEF SYSTEM The system for safely relieving excess pressure to avoid exceeding equipment design pressure. STANDARD CUBIC FEET Gas volume at standard temperature and pressure. SOLUTION GAS Gas which originates from the liquid phase in an oil reservoir. SPECIFIC GRAVITY The ratio of the mass of a given volume of a substance to that of another equal volume of another substance used as a standard. Air is used as the standard for gas and water for liquids, with the volumes measured at 60 degrees Fahrenheit and atmospheric pressure. TRAYED TOWER A vessel wherein gas and liquid are contacted, usually countercurrent on trays. WET GAS A gas containing water, or a gas that has not been dehydrated 39

PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017) Use scantron to answer all questions PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017) 1. The term dehydration of natural gas means A. addition of water vapor B. removal of water

More information

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID Miss Nur Izzati Bte Iberahim Introduction Well effluents flowing from producing wells come out in two phases: vapor and liquid

More information

Application Worksheet

Application Worksheet Application Worksheet All dimensions are nominal. Dimensions in [ ] are in millimeters. Service Conditions Medium Through Valve: Required C v : Temperature Maximum: Minimum: Normal: Flow Maximum: Minimum:

More information

OIL AND GAS SEPARATION DESIGN MANUAL

OIL AND GAS SEPARATION DESIGN MANUAL OIL AND GAS SEPARATION DESIGN MANUAL BY C. RICHARD SIVALLS, P.E. SIVALLS, INC. BOX 2792 ODESSA, TEXAS 79760 All rights reserved. This publication is fully protected by copyright and nothing that appears

More information

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146 PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT Purpose STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146 This paper is designed to serve as an update to the paper formally

More information

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT Introduction Stormy Phillips Product Manager Legacy Measurement Solutions 9726 East 42nd Street Suite 219 Tulsa, OK 74126 The condition of gas as it

More information

OIL AND GAS PROCESSES AND EMISSIONS

OIL AND GAS PROCESSES AND EMISSIONS OIL AND GAS PROCESSES AND EMISSIONS This document provides a brief description of oil and gas activities, equipment and expected pollutants from those equipment types. The emissions processes are discussed

More information

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Pipe-Away Pressure Vacuum Vent /Conservation Vent R R Pressure Vacuum Vent / End of Line Conservation Vent Flame Arrester with Pressure Vacuum Vent Pipe Away Pressure Vacuum Vent / Conservation Vent Vacuum Relief Vent Pressure Emergency Vent Free Vents

More information

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor moisture starts to condense out of the air. The temperature at which this happens is called the dew point temperature, or the saturation temperature. What is commonly called saturation pressure or condensing

More information

Efficient Pigging of Gathering Lines. Energy Management Workshop for Upstream and Midstream Operations

Efficient Pigging of Gathering Lines. Energy Management Workshop for Upstream and Midstream Operations Efficient Pigging of Gathering Lines Energy Management Workshop for Upstream and Midstream Operations January 17, 2007 Agenda Methane Losses from Pipeline Pigging Methane Recovery Industry Experience Is

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

APPENDIX C TANK BATTERIES

APPENDIX C TANK BATTERIES C-i APPENDIX C TANK BATTERIES C - 1. Understanding the Tank Battery. 1. Openings to Vessels for Lines. 2. The Shape and Purpose of Vessels. 3. From the Well to the Tank Battery. C-1 The Lease Pumper s

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2

Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2 37 Journal of Chemical Engineering, IEB Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2 Abstract 1 Bibyana Gas Field 2 Department of Petroleum

More information

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 13.7 Pressure Equipment Directive (PED) 97/23/EC 1 The Pressure Equipment Directive (PED) 97/23/EC applies to the design, manufacturing and conformity

More information

CURI Pierside Stainless Diesel Tank

CURI Pierside Stainless Diesel Tank Mechanical Integrity Report for the CURI Pierside Stainless Diesel Tank at 208 North Palmetto Boulevard Clemson, South Carolina 29631 Inspection: 26 September 2012 Prepared by: George E. Matthews, E.I.T.

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Fundamentals Of Petroleum Engineering PRODUCTION

Fundamentals Of Petroleum Engineering PRODUCTION Fundamentals Of Petroleum Engineering PRODUCTION Mohd Fauzi Hamid Wan Rosli Wan Sulaiman Department of Petroleum Engineering Faculty of Petroleum & Renewable Engineering Universiti Technologi Malaysia

More information

Chapter 13 Gases, Vapors, Liquids, and Solids

Chapter 13 Gases, Vapors, Liquids, and Solids Chapter 13 Gases, Vapors, Liquids, and Solids Property is meaning any measurable characteristic of a substance, such as pressure, volume, or temperature, or a characteristic that can be calculated or deduced,

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Natural Gas Conditioning Skids & Equipments

Natural Gas Conditioning Skids & Equipments Natural Gas Conditioning Skids & Equipments NATURAL GAS CONDITIONING SKIDS NIRMAL has rich experience of supplying complete package of Natural Gas conditioning skids consisting of emergency shut down,

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage 94060 The Shand & Jurs model 94060 Conservation Vent is constructed of Fiberglass Reinforced Plastic (FRP). It has been designed for superior corrosion resistance in oxidizing environments. The 94060 is

More information

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage 94060 The Shand & Jurs model 94060 Conservation Vent is constructed of Fiberglass Reinforced Plastic (FRP). It has been designed for superior corrosion resistance in oxidizing environments. The 94060 is

More information

Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation

Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation William Echt & Jeff Cook Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation WILLIAM ECHT / JEFF COOK (USA) William Echt. William.echt@uop.com Technology Manager

More information

Model 1800 PFM Series Regulator. Technical Bulletin

Model 1800 PFM Series Regulator. Technical Bulletin Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane

More information

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.] OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7 [Comrnencernent.] [22nd April, 1968] 1. Short title and interpretation (1) These Regulations may be cited as the Oil in Navigable

More information

At the end of this lesson, you will be able to do the following:

At the end of this lesson, you will be able to do the following: Liquid-Phase Contacting Scrubbers Goal To familiarize you with the operation, collection efficiency, and major maintenance problems of liquid-phase contacting scrubbers. Objectives At the end of this lesson,

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed. GLOSSARY OF TERMS Absolute pressure Total pressure measured from absolute zero i.e. a perfect vacuum. As a practical matter, gauge pressure plus atmospheric pressure. Absolute temperature Temperature measured

More information

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions 0575050/2 IM-P057-04 CH Issue 2 IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions 1 Safety information 2 General product information 3 Installation and commissioning

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

Facilities Design Shift Horizontal Equipment in Oklahoma Scott King

Facilities Design Shift Horizontal Equipment in Oklahoma Scott King Facilities Design Shift Horizontal Equipment in Oklahoma Scott King Facilities Review in Oklahoma Identified areas for improvement Design criteria is outdated for play types Vertical separation, cannot

More information

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN 520 LAFAYETTE ROAD NO., ST. PAUL, MN 55155-4194 NSPS FORM NSPS-Ka NSPS SUBPART Ka Check-off Form JULY 11, 2005 I. Introduction An owner or operator may fill in this form in replacement of a highlighted

More information

Compressed Gases and Cryogens

Compressed Gases and Cryogens Compressed Gases and Cryogens University of Tennessee Safety Guide HM-011 Document Contact: EHS Date effective: January 1, 2009 Revision Date: October 1, 2015 Purpose This guideline adheres to the Occupational

More information

Vortex Tube Short Course February 2017

Vortex Tube Short Course February 2017 Vortex Tube Short Course February 2017 10125 Carver Rd. Cincinnati, OH 45242 1.800.441.7475 sales@vortec.com Vortex Tube Short Course The vortex tube has been around for decades, yet occasionally it is

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is adopted as part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following factors must

More information

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol IOSR Journal of Applied Chemistry (IOSRJAC) ISSN : 2278-5736 Volume 2, Issue 2 (Sep-Oct. 212), PP 1-6 Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol Khan, Mohd

More information

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) TEE (HOT TAPPING MATERIAL) S-04-02-040 Page 1 of 7 1.0 SCOPE This specification covers the basic requirements for the design, manufacture and supply

More information

PRODUCT GUIDE Spring 2015

PRODUCT GUIDE Spring 2015 PRODUCT GUIDE Spring 2015 A COMPANY FOUNDED ON SERVICE During his 35 year tenure in the compressed gas and welding supply business, George Bennett identified service as the core value that leads to success.

More information

FV Flash Vessel Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions 4041050/5 IM-P404-10 EMM Issue 5 FV Flash Vessel Installation and Maintenance Instructions 1. Safety information 2. Specific product safety information 3. Product information 4. Installation 5. Commissioning

More information

GAS DEHYDRATION SYSTEM

GAS DEHYDRATION SYSTEM GAS DEHYDRATION SYSTEM High pressure gases from the Gas Compressors (CBA-4070/4020) flow to the Glycol Contactor (MAF-1150). In the Contactor, gas flows through trays, contacting the lean glycol that is

More information

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 3501 GENERAL 3501.1 Scope. The storage and use of flammable gases shall be in accordance with this chapter. Compressed gases shall also

More information

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions PREVIOUS REFERENCE NO. IMP02355 0231150/13 IMF0501ENISS2 CMGT S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

GAS DEHYDRATION SYSTEM

GAS DEHYDRATION SYSTEM GAS DEHYDRATION SYSTEM High pressure and compressed gases flow through the Gas Scrubber (MBF-4540) to the Glycol Contactor (MAF-0900). In the Contactor, gas flows through trays, contacting the lean glycol

More information

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Advanced Management of Compressed Air Systems Pre-Workshop Assignment Advanced Management of Compressed Air Systems Page 1 In order to ensure that the Compressed Air Challenge Level II Training is most useful to you, it will be important for you to bring information about

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 1100 Sanitary Vent IOM-1100 03-17 ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1100 is a stainless steel sanitary vent designed

More information

Pressure Systems Safety Regulation

Pressure Systems Safety Regulation Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2003 International Fuel Gas Code, coordinated with

More information

North American 7337A/B/C-4 High Pressure Gas Regulators

North American 7337A/B/C-4 High Pressure Gas Regulators Combustion North American A/B/C-4 High Pressure Gas Regulators Bulletin A/B/C-4 A-4, B-4 and C-4 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the

More information

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax 6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation

More information

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system Bulletin 061013 TCR-104 & 109 Filling and adding to the Glycol pressure system 1. Glycol System and air On this model the glycol system is a closed system, the glycol is not exposed to the air. No external

More information

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473 DUE: May 23 ASSIGNMENT 2 CHE 3473 #Problem 1: 3.3 #Problem 2: 3.4 #Problem 3: 3.5 #Problem 4: 3.6 #Problem 5: 3.7 #Problem 6: 3.8 #Problem 7: 3.11 #Problem 8: 3.15 #Problem 9: 3.22 #Problem 10: 3.32 #Problem

More information

Simplicity in VRU by using a Beam Gas Compressor

Simplicity in VRU by using a Beam Gas Compressor Simplicity in VRU by using a Beam Gas Compressor By Charlie D. McCoy and Mark Lancaster Abstract: Vapor Recovery Units are often expensive, complicated to operate and unable to deal with High H2S and liquids.

More information

Digester Processes. 1. Raw Sludge Pumping System

Digester Processes. 1. Raw Sludge Pumping System Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412) SECTION Bypass Oil Sampling Station (B.O.S.S 1000) GENERAL.......................... SAFETY........................... Hazards............................... Personal Protective Equipment........... PRODUCT

More information

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR SELECTION, Corresponding IS does not exist

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR SELECTION, Corresponding IS does not exist INTERPLANT STANDARD - STEEL INDUSTRY IPSS CODE OF PRACTICE FOR SELECTION, LAYING OF MOIST FUEL GAS LINES Corresponding IS does not exist IPSS:1-06-014-17 (Third Revision) Formerly : IPSS:1-06-014-02 (Second

More information

Use equation for the cylindrical section and equation or for the ends.

Use equation for the cylindrical section and equation or for the ends. Solution 13.1 See section 13.3.4, equations 13.7 to 13.18 Solution 13.2 Use equation 13.34. (a) rigid constant C = 0.43 (b) free to rotate, C = 0.56 Solution 13.3 See section 13.5.1 Use equation 13.39

More information

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS Quiz #1 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS An astronaut has a mass of 161 lbm on the surface of the earth. Calculate his weight (in lbf) on planet Rigel 4 where g = 20.0 ft/s

More information

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473 DUE: May 21 ASSIGNMENT 2 CHE 3473 #Problem 1 Read Chapter 3. ALL OF IT. Time yourself and report the time. #Problem 2: 3.2 #Problem 3: 3.3 #Problem 4: 3.5 #Problem 5: 3.6 #Problem 6: 3.7 #Problem 7: 3.8

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Yutaek Seo. Subsea Engineering

Yutaek Seo. Subsea Engineering Yutaek Seo Subsea Engineering Inlet receiving Gas and liquids that enter the gas processing facilities pass emergency shutdown valves, and then go to inlet receiving, where condensed phases drop out. Gas

More information

GAS DEHYDRATION SYSTEM

GAS DEHYDRATION SYSTEM GAS DEHYDRATION SYSTEM High pressure and compressed gases flow to the Glycol Contactor (MAF-3110). In the Contactor, gas flows through trays, contacting the lean glycol that is flowing across the trays

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

SECTION DIGESTER GAS SAFETY AND CONTROL EQUIPMENT

SECTION DIGESTER GAS SAFETY AND CONTROL EQUIPMENT SECTION 11486 DIGESTER GAS SAFETY AND CONTROL EQUIPMENT PART 1 -- GENERAL 1.01 THE REQUIREMENT A. The Contractor shall furnish and install gas safety and control equipment as specified herein and shown

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Standard Operating and Maintenance Instructions for Pumping System Model PS-150 Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

Energy Specialties International

Energy Specialties International Company Information Company: Address: Engineer: Phone: Fax: E-mail: Skim Pile Information Deck Area: Water Depth: Rainfall Intensity: Cellar Deck El.: Boat Deck El.: Continuous or Intermittent Flow: Oil

More information

Type ACE95jr Tank Blanketing Valve

Type ACE95jr Tank Blanketing Valve Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained

More information

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES TECHNICAL BULLETIN 1049 - TB 3-16 Model 1049 Secure-Gard Pilot Operated Vent Valve (POVV) ISO Registered Company The Model 1049 is a pilot operated vent valve specifically designed for low-pressure storage

More information

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1 November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:

More information

Tank Blanketing. Application Jordan Valve Product Offering Competition

Tank Blanketing. Application Jordan Valve Product Offering Competition Tank Blanketing Application Jordan Valve Product Offering Competition What is Tank Blanketing? Padding the process of filling the empty space of a liquid storage tank with an inert gas, most likely Nitrogen

More information

ENGINEERING FLUID MECHANICS

ENGINEERING FLUID MECHANICS DEPARTMENT of MECHANICAL ENGINEERING FLUID MECHANICS Subject code: 10ME46B Faculty name: Naveen H E QUESTION BANK UNIT-1: FLUID PROPERTIES 1. Define the following: i) density, ii) weight density, iii)

More information

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch. Training Title GAS CONDITIONING & PROCESSING Training Duration 5 days Training Venue and Dates Gas Conditioning & Processing 5 07 11 April, 2019 $4,000 Dubai, UAE Trainings will be conducted in any of

More information

DISTILLATION POINTS TO REMEMBER

DISTILLATION POINTS TO REMEMBER DISTILLATION POINTS TO REMEMBER 1. Distillation columns carry out physical separation of liquid chemical components from a mixture by a. A combination of transfer of heat energy (to vaporize lighter components)

More information

MAINTENANCE AND OPERATING MANUAL

MAINTENANCE AND OPERATING MANUAL MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

ETHOS Environmental and Thermal Operating Systems (ETHOS)

ETHOS Environmental and Thermal Operating Systems (ETHOS) ISS Live! was developed at NASA s Johnson Space Center (JSC) under NASA Contracts NNJ14RA02C and NNJ11HA14C wherein the U.S. Government retains certain rights. Console Handbook ETHOS Environmental and

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM Faculty of Chemical Engineering CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM SUBMISSION DATE: 1 OCT. 2012 Question 1 Name the following equipments based on standard P&ID

More information

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS INTERNATIONAL MARITIME ORGANIZATION A 14/Res.567 16 January 1986 Original: ENGLISH ASSEMBLY - 14th session Agenda item lo(b) IMO RESOLUTION A.567(14) adopted on 20 November 1985 THE ASSEMBLY, RECALLING

More information

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free

More information

Series 8500 Expansion Compensators. Catalog 674H

Series 8500 Expansion Compensators. Catalog 674H Series 8500 Expansion Compensators Catalog 674H 500 Laminated Bellows Expansion J Series 8500 on Joints Expansion Compensators Sizes 3/4" through 4" Threaded, welded, flanged and grooved steel pipe joints

More information

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada Acid gas is a mixture of hydrogen sulfide and carbon dioxide, with

More information